l DATA SHEET l

NETSCOUT Certified InfiniStreamNG


Software Appliance
Smart Visibility for Service Assurance, Cybersecurity,
and NETSCOUT Smart Edge Monitoring

NETSCOUT InfiniStreamNG® (ISNG) software and hardware appliances use our patented
Adaptive Service Intelligence® (ASI) technology to generate the NETSCOUT “Smart Data” required
HIGHLIGHTS for continuous and uniform visibility across today’s large-scale network environments. Our
nGeniusONE® Service Assurance platform’s smart analytics consume this smart data to supply
• Components selected and matched to
information technology (IT) teams and service providers with views, alerts, and reports on key
NETSCOUT® use case
performance indicators, network and application error details, specialized service monitors,
• Performance and availability optimized
session records, and packet decodes.
configuration
• Available with 1G, 10G, 40G, and 100G In addressing monitoring needs in very large environments, multiple ISNG software and
interface options for network flexibility hardware appliances can be installed to provide virtually unlimited scalability. ISNG appliances
• Supports deployment in the NETSCOUT can be deployed alongside our vSTREAM® virtual appliances to expand visibility into both multi-
Smart Edge Monitoring and Omnis® cloud (e.g., Amazon Web Services, Google Cloud, Microsoft Azure, Oracle Cloud Infrastructure)
Cyber Intelligence Threat Detection and and virtual (e.g., VMware NSX-V and NSX-T) environments.
Investigation solutions
• Award-winning NETSCOUT MasterCare NETSCOUT Certified InfiniStreamNG Software Appliance Overview
Support coverage for software The NETSCOUT Certified Software Appliance solution factors deployment of a customer-
and hardware provided hardware platform certified to support ISNG software.

Since network speeds, processing, and capacity needs vary, NETSCOUT offers several ISNG Certified
Software Appliance models with different interface and storage capacities. Various ISNG models
can be deployed in tandem for seamless analysis across the entire network, making it easier and
more cost-effective to monitor and gather intelligence from multiple sources, with no disruption to
business processes. Equally significant, NETSCOUT offers ISNG Certified ISNG Software Appliance
models designed for deployment in any environment, ranging from the network edge, small remote
facilities, satellite offices, and disaster recovery locations, onto the data center core.

NETSCOUT Certified Software Appliances offer 100% performance parity with NETSCOUT’s
factory-integrated ISNG hardware appliances. Additionally, NETSCOUT provides our award-winning
MasterCare annual support coverage for the Certified ISNG software and Network Interface Card
(NIC) kit, as well as the Certified InfiniStreamNG Server, resulting in single-source system support
for enterprise, cybersecurity, and service provider IT teams. Additionally, ISNG Certified Software
Appliances configured with the NETSCOUT Edge Adaptor module provide service visibility in our
Smart Edge Monitoring solution. For existing customers, our Omnis Cyber Intelligence Threat
Detection and Investigation Platform can also leverage ISNG as a cyberanalytics data source by
enabling a NETSCOUT Omnis Cyber Adaptor software license.

N ET S COUT
l DATA SHEET l NETSCOUT Certified InfiniStreamNG Software Appliance

Certified InfiniStreamNG Software


The Certified InfiniStreamNG Software component of Certified ISNG Software Appliances is
unbundled from the underlying Certified ISNG Server. This configuration provides customers the
flexibility of a software-based approach with the performance and reliability of traditional ISNG
hardware appliances. The Certified ISNG Software component, which includes the ASI NIC, is
ordered directly from NETSCOUT.

Certified InfiniStreamNG Server


The Certified ISNG Software Appliances differ from the traditional InfiniStreamNG hardware
appliances, in that the server hardware is unbundled from the Software and ASI NIC. The
Certified ISNG Servers are offered in a variety of hardware configurations to meet a broad
range of performance and storage requirements. With guidance from NETSCOUT, customers
independently order these servers from a NETSCOUT Certified Supplier.

NETSCOUT Certified InfiniStreamNG Software Appliance Specifications


Acquired from NETSCOUT

C-01400 C-02600 C-02700 C-04800 C-06600 C-09800 Series


Series Series Series Series Series

Software NETSCOUT Certified InfiniStreamNG Software

NETSCOUT 30 Watts including SFP+ SR modules 10 GbE: 30 Watts, including SFP+ SR modules
ASI Operating Temperature: 0°C to 45°C (32°F to 113°F) 40 GbE: 75 Watts, including QSFP+ modules
Accelerator Operating Humidity: 20% to 80% 100 GbE: 75 Watts, including QSFP28
NIC Power modules
Consumption Operating Temperature: 0 °C to 45 °C
(32 °F to 113 °F)
Operating Humidity: 20% to 80%
Dimensions: 1/2 length, full height

NETSCOUT 4 x 1 GbE SFP 4x 1 GbE SFP or 1/10 GbE SFP+ 10/1 GbE: 4x 1 GbE SFP or 10 GbE SFP+
ASI 40 GbE: 2x 40 GbE QSFP+
Accelerator 100 GbE: 2x 100 GbE QSFP28
Monitoring
Ports

Transceivers SFP: SFP: Multi-mode SX, single-mode LX, 1000BASE-T SFP: Multi-mode SX, single-mode LX,
(Ordered Multi-mode SX, SFP+: Multi-mode SR, single-mode LR 1000BASE-T
separately single-mode LX, SFP+: Multi-mode SR, single-mode LR
from 1000BASE-T QSFP+: Multi-mode SR4, Single-mode LR4
NETSCOUT)
QSFP28: Multi-mode SR4, Single-mode LR4

Table 1: NETSCOUT Certified ISNG Software Appliance Specifications.

N ET S COUT 2
l DATA SHEET l NETSCOUT Certified InfiniStreamNG Software Appliance

Acquired from a NETSCOUT Certified Supplier

C-01400 Series C-02600 Series C-02700 Series C-04800 Series C-06600 Series C-09800 Series

Server C-01400 Certified C-02600 Certified C-02700 Certified C-04800 C-06600 C-09800
InfiniStreamNG InfiniStreamNG InfiniStreamNG NETSCOUT NETSCOUT NETSCOUT
Server Server Server Certified Certified Certified
InfiniStreamNG InfiniStreamNG InfiniStreamNG
Server Server Server

Processor Single 8-core Single 12-core Single 22-Core Dual 22-core Single 12-core Dual 22-Core
processor processor processor processors processor processors

Memory 6x 16GB DDR4 6x 32GB DDR4 12x 32GB DDR4 6x 32GB DDR4 12x 32GB DDR4
(96GB Total) (192GB Total) (384GB Total) (192GB Total) (384GB Total)

Storage 8TB 16TB (RAID 5) 32TB (RAID 5) 32TB (RAID 5) up 48TB (RAID 6) 128TB up to
4x 4TB, 3.5” NL-SAS 4x 8TB, 3.5” NL-SAS to 160TB with ESU 12x 4TB, 3.5” 384TB with up to 2
HDD, 512e sector HDD, 512e sector (RAID 6) NL-SAS ESUs (RAID 6), 16x
size, 12Gb/s size, 12Gb/s 4x 8TB, 3.5” NL-SAS HDD, 512e sector 8TB, 3.5” NL-SAS/
HDD, 512e sector size, 12Gb/s SAS HDD, 512e
size, 12Gb/s sector size, 12Gb/s

Management Two onboard Gigabit/10 Gigabit Ethernet LAN RJ45 ports (eth0 used for management)
Port One dedicated 1-Gigabit IPMI port for remote management

Embedded OS Solid State Drive (SSD) dedicated to Linux® OS

Rack Unit 1 Rack Unit (1RU) 3 Rack Unit (3RU)

Dimensions Height: 1.7 in (43 mm) Height 5.2 in (132 mm)


Width: 17.2 in (437 mm) Width: 17.2 in (437 mm)
Depth: 25.6 in (650 mm) Depth: 25.5 in (648 mm)

Weight 38 lbs. (17.24 kg) 82 lbs. (37.19 kg)

Mounts Rack mount side rails included

N ET S COUT 3
l DATA SHEET l NETSCOUT Certified InfiniStreamNG Software Appliance

Environmental Specifications (Appliance with NETSCOUT ASI NIC Installed)

C-01400 Series C-02600 Series C-02700 Series C-04800 Series C-06600 Series C-09800 Series

Power Rating 700W/750W hot swappable, redundant, auto-ranging: Hot swappable, redundant
(AC) 700W: 100-140 VAC, 50-60 Hz, 8.0-6.0 Amp 1000W: 100-127V, 15-12A, 50-60Hz
750W: 200-240 VAC, 50-60 Hz, 4.5-3.8 Amp 1200W: 200-240V, 8.5A-7A, 50-60Hz

Maximum 6.5A, 655W 100V, 9.8A, 1000W


Consumption (AC)

Power Rating -48VDC, 650W, 20A (x2), hot-swappable, redundant 48VDC, 1010W, 24A (x2),
(DC) hot‑swappable, redundant

Maximum 13.7A, 658W 21.7A, 1042W


Consumption (DC)

Vibration 0.25G from 5-200Hz for 15 minutes 0.75G at 5-200 Hz

Altitude -50 to 10,000 ft (-16 to 3,048 m) -45 to 9,500 ft (-13.7m to 2,896 m)

Mechanical
1 shock pulse up to 20G for up to 2.5ms 1 shock pulse up to 40G for up to 2ms
Shock

Regulatory Regulatory Model Number: NV51U, FCC Part 15 Class A, CE Mark (EN55032 Class Regulatory Model Number: NV53U,
Approvals A, EN 55024, EN 61000-3-2, EN 61000-3-3), VCCI (Japan) Class A, RRA (Korea) KC FCC Part 15 Class A, CE Mark (EN55032
Cert #: R-R-NSZ-NV51U, CCC Class A (China), EAC (Russia), BIS (India), CM (Morocco), Class A, EN 55024, EN 61000-3-2, EN
UL‑C of C (Mexico), BSMI (Taiwan), LoA (South Africa), UL 60950-1/62368-1, 61000-3-3), VCCI (Japan) Class A, RRA
CAN/CSA C22.2 No. 60950/62368-1, IEC 60950-1/62368-1, EN 60950-1/62368-1, (Korea) KC Cert #: R-R-NSZ-NV53U, CCC
CB Report Class A (China), EAC (Russia), BIS (India),
CM (Morocco), UL- C of C (Mexico),
BSMI (Taiwan), LoA (South Africa), UL
60950-1/62368-1, CAN/CSA C22.2 No.
60950/62368-1, IEC 60950-1/62368-1,
EN 60950-1/62368-1, CB Report

Temperature Specifications

Storage –40°C to 65°C (–40°F to 149°F)

Continuous operation (for altitude 10°C to 35°C (50°F to 95°F) with no direct sunlight on
less than 950 m or 2953 ft) the equipment

Maximum temperature gradient 20°C in an hour (36°F/h) and 5°C in 15 minutes


(operating and storage) (9°F/15 min)

Operational altitude de‑rating Maximum temperature is reduced by 1°C/300 m


(1.8°F/984 Ft) above 900 m (2953 Ft)

Table 2: Temperature Specifications.

Relative Humidity Specifications

Storage 5% to 95% RH with 33°C (91°F) maximum dew point.


Atmosphere must be non-condensing at all times.

Operating 10% to 80% relative humidity with 29°C (84.2°F)


maximum dew point, non-condensing

Table 3: Relative Humidity Specifications.

N ET S COUT 4
l DATA SHEET l NETSCOUT Certified InfiniStreamNG Software Appliance

The C-04800 Series and C-09800 Series Certified ISNG appliances offer additional support for
configuration of an optional ESU, as defined in Table 4 The C-04800 supports addition of one
ESU, and the C-09800 supports addition of one or two ESUs.

ESU Components C-04800 Series and C-09800 Series ESU Specifications

Storage 128TB (RAID 6)

Hard Drives (16) Sixteen 3.5" NLSAS/SAS Disk, 8TB, 512e sector size, 12 Gb/s

Rack Unit 3 Rack Unit (3RU)

Dimensions 5.2 in (132 mm) Height


17.2 in (437 mm) Width
25.5 in (648 mm) Depth

Weight 70.35 lbs. (31.91 kg)

Mounts Rack mount side rails included

Power Rating (AC) 1000W: 100-127V, 15-12A, 50-60Hz


1200W: 200-240V, 8.5A-7A, 50-60Hz
Hot swappable, redundant

Maximum 2.8A, 280W


Consumption (AC)

Heat Dissipation (AC) 955 BTU/Hr

Power Rating (DC) -48VDC, 1010W, 24A (x2) hot-swappable, redundant

Maximum 6A, 285W


Consumption (DC)

Heat Dissipation 972 BTU/Hr


(DC)

Vibration 0.75G at 5-200 Hz

Operating 50° to 95°F (10° to 35°C)


Temperature

Operating Humidity 8% - 90% (non-condensing)

Altitude -45 to 9,500 ft (-13.7m to 2,896 m)

Mechanical Shock 1 shock pulse up to 40G for up to 2ms

Regulatory Regulatory Model Number: NE123U, FCC Part 15 Class A, CE Mark (EN 55032 Class A, EN 55024, EN 61000-3-2,
Approvals EN 61000-3-3), VCCI (Japan) Class A, RRA (Korea) KC Cert #: KCC- REM-NSZ-NE123U, UL 60950-1, CQC Class A (China),
EAC (Russia), BIS (India), CM (Morocco), UL- C of C (Mexico), CAN/CSA C22.2 No. 60950, IEC 60950-1, UL 60950-1/62368-1,
CAN/CSA C22.2 No. 60950/62368-1, IEC 60950-1/62368-1, EN 60950-1/62368-1, CB Report UL-GS (DEMKO)

Table 4: C-04800 Series and C-09800 Series Certified ISNG Appliance ESU Specifications.

Corporate Headquarters Sales Information Product Support


NETSCOUT Systems, Inc. Toll Free US: 800-309-4804 Toll Free US: 888-357-7667
Westford, MA 01886-4105 (International numbers below) (International numbers below)
Phone: +1 978-614-4000
www.netscout.com

NETSCOUT offers sales, support, and services in over 32 countries. Global addresses, and international numbers are
listed on the NETSCOUT website at: www.netscout.com/company/contact-us

© 2022 NETSCOUT SYSTEMS, INC. All rights reserved. NETSCOUT, the NETSCOUT logo, Omnis, Guardians of the Connected World, Adaptive Service Intelligence, Arbor, ATLAS, InfiniStream,
nGenius, and nGeniusONE are registered trademarks or trademarks of NETSCOUT SYSTEMS, INC., and/or its subsidiaries and/or affiliates in the USA and/or other countries.
Third-party trademarks mentioned are the property of their respective owners.
NSPDS_037_EN-2201 05/2022

You might also like