0% found this document useful (0 votes)
71 views3 pages

Edwards Door Holders

Edwards electromagnetic door holders are ruggedly constructed and attractively designed to hold doors open while energized and release when de-energized. They are available in floor or wall mounted styles and have a minimum holding force of 25 lbs. They are used to control the spread of smoke and fire during a fire alarm.

Uploaded by

enanoedintel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
71 views3 pages

Edwards Door Holders

Edwards electromagnetic door holders are ruggedly constructed and attractively designed to hold doors open while energized and release when de-energized. They are available in floor or wall mounted styles and have a minimum holding force of 25 lbs. They are used to control the spread of smoke and fire during a fire alarm.

Uploaded by

enanoedintel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Fire & Life Safety

Accessories
Part of GE Security

Overview Standard Features


Edwards Signaling Electromagnetic Door Holders are ruggedly • Floor and wall mounted styles
constructed and attractively designed. The housing is finished with
• Low power consumption
an aluminum color, durable baked polyester powder paint. The floor
or wall section houses the electromagnet while the contact plate • AC/DC models
attaches to the door. The contact plate has a shock absorbing nylon • Completely silent operation
(swivel) ball which allows the plate to adjust to any door angle. Floor
units are available in single-door or double-door (back to back) ver- • 25 Lbf (111N) minimum holding force
sions. Wall units are available in flush or surface mounted versions. • Adjustable, swivel contact plate
Edwards door releases should be installed wherever doors may
be effectively used to confine smoke and fire, or where the release
of a self-closing door from a remote location is desirable for other Basic Models
reasons.
Floor Mounted:
Fail-safe operation is an inherent feature of Edwards Signaling door The electromagnet portion consists of a housing, gasket, and
holder-releases. If power fails, doors are released automatically but mounting plate for direct mounting to the floor. Incoming conduit
may be opened or closed manually at any time. All units are free of connects directly into floor plate.
moving parts, are self-contained and require no maintenance. Floor mounted units are available with one (Cat. No. 1501) or two
These door holder-releases have a minimum holding force of 25 (Cat. No. 1502) magnet faces for holding a single door or two doors
lbs (111N). The device holds a door open while energized. When back to back.
de-energized by a relay controlled by the fire alarm system or Wall Mounted:
other switch, the door is released to a closed position, checking the Wall mounted models are available in flush, semi-flush and surface
spread of smoke and flames. Electromagnetic door holders should mounting configurations. Flush and semi-flush models are designed
be used and installed in accordance with local Building Codes and for concealed wiring applications and mount on standard single
Standards. gang (2 x 4 inch) outlet boxes. Surface mounted models mount on a
surface adaptor housing (junction box), which is provided.

Electromagnetic
Door Holders
MEA

Pending
Distributed By: LEE DAN COMMUNICATIONS, INC.
www.leedan.com [email protected] Toll-Free: 1-800-231-1414

Data Sheet S85001-0421 Issue 6.1


Not to be used for installation purposes. Page  of 4
Dimensions

1504-AQN5 Flush Wall Mounted (Long Catch Plate) 1505-AQN5 Flush Wall Mounted (Short Catch Plate)

1501-AQN5 Floor Mounted (Single Door) 1508-AQN5 Surface Wall Mounted

8" max. / 6.37" min.


(203.2 mm max. / 161.8 mm min.)

1502-AQN5 Floor Mounted (Double Door) 1509-AQN5 Completely Flush Wall Mounted
12" max. / 8.37" min.
(304.8 mm max. / 212.6 mm min.)

Catch Plate Extensions


Only the extension rods are included. The end pieces are included
2.342"
with the doorholders or can be ordered separately. (59.5 mm)
2.0"
1.5" (50.8 mm)
(38 mm) 1.68"
8" max. / 6.37" min. (47.7 mm)
(203.2 mm max. / 161.8 mm min.)
1500-1 1500-2

1500-7
4.125" 4.625"
3.125" 3.625" (104.8 mm) (117.5 mm)
12" max. / 8.37" min. (79.4 mm) (92 mm)
(304.8 mm max. / 212.6 mm min.)

1500-1 1500-2 1500-1 1500-2


1500-12

2.342"
(59.5 mm)
2.0"
1.5" (50.8 mm)
(38 mm) 1.68"
(47.7 mm)

Distributed
4.125" By: LEE
4.625" DAN COMMUNICATIONS, INC.
3.625" (104.8 mm) (117.5 mm)
3.125"
(92 mm) www.leedan.com [email protected] Toll-Free: 1-800-231-1414
(79.4 mm)

Data Sheet S85001-0421 Issue 6.1


Not to be used for installation purposes. Page  of 4
Specifications
Model No. Style Volts Amps*
1501-AQN5 Floor Mounted (Single Door)
1502-AQN5 Floor Mounted (Double Door)
1504-AQN5 Flush Wall Mounted (Long Catch Plate) 24 Vac 60 Hz
.015
1505-AQN5 Flush Wall Mounted (Short Catch Plate) 24 Vdc 120 Vac 60 Hz
1508-AQN5 Surface Wall Mounted
1509-AQN5 Completely Flush Wall Mounted
*1502-AQN5 is a double unit which draws .015 per side

Ordering Information
Ship. Wt.
Model No. Description
lb (kg)
1501-AQN5 Floor Mounted (Single Door) 5.4 (2.45)
1502-AQN5 Floor Mounted (Double Door) 5.0 (2.27)
1504-AQN5 Flush Wall Mounted (Long Catch Plate) 2.0 (0.91)
1505-AQN5 Flush Wall Mounted (Short Catch Plate) 2.0 (0.91)
1508-AQN5 Surface Wall Mounted 3.0 (1.36)
1509-AQN5 Completely Flush Wall Mounted 2.0 (0.91)

Accessories
1500-1 Catch plate extension assembly, 1.5” 0.25 (0.11)
1500-2 Catch plate extension assembly, 2.5” 0.25 (0.11)
1500-7 Catch plate extension assembly (5.25 to 7.5 inches) 0.5 (0.23)
1500-12 Catch plate extension assembly (7.5 to 12 inches) 1.0 (0.45)
CS2595-5 Replacement armature - short (for use with 1501, 1502, 1505, 1508 and 1509 door holders) 0.25 (0.11)
CS2598-5 Replacement armature - long (for use with 1504 door holder) 0.25 (0.11)

CAUTION: These Door Holder units will not operate without electrical power.

Distributed By: LEE DAN COMMUNICATIONS, INC.


www.leedan.com [email protected] Toll-Free: 1-800-231-1414

Data Sheet S85001-0421 Issue 6.1