This document provides information about transmission harness and fender harness components for tractors. It includes diagrams labeling various components and notes about replacing relays, specifying that grey resistor protected relays must be replaced with black diode suppressed relays if replaced. The diagrams and notes give instructions for tractor electrical system maintenance and repairs.

Uploaded by

moyali25176750
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
21 views

FOLDOUTS and SCHEMATIC CIRCUITS

This document provides information about transmission harness and fender harness components for tractors. It includes diagrams labeling various components and notes about replacing relays, specifying that grey resistor protected relays must be replaced with black diode suppressed relays if replaced. The diagrams and notes give instructions for tractor electrical system maintenance and repairs.

Uploaded by

moyali25176750
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

10006- 91

Transmission Harness and Fender Harness Components


3
2

22
27 26

m
co 21 20 19
18
G5
s.

28
og

DI99M095 1
20
l
ta
ca

3
7
ep

24 1. CO
2. WH
3. HI
4. FO
5. RE
6. PA
7. LE
8. FU
9. CL
10. HY
11. HY
23 12. PO
13. PO
25 14. SP
15. SP
16. HI

Don 7-73281 Issued 1-00


FORWARD/NEUTRAL/REVERSE OPERATOR SEAT SWITCH

m
co
s.
l og
ta
ca
ep

DI98k087
10006- 93

PARK BRAKE SWITCH, PTO SOLENOID AND AUDIBLE ALARM PTO CONTROLLER

m
co
s.
l og
ta
ca
ep

NOTE 5: Grey relays are resistor protected and Black relays are diode suppressed. Black diode
suppressed relays MUST be grounded through terminal 2 and switched through terminal 1. Early
tractors equipped with grey resistor protected relays are grounded through terminal 1. Later tractors
with grey resistor protected relays are grounded through terminal 2.
IMPORTANT: If a Grey resistor protected relay is to be replaced, it MUST be replaced with a Black
diode suppressed relay. In may be necessary to change terminals 1 and 2 in the relay terminal block.
The Brown chassis ground wire must be installed into terminal 2 and the relay switching wire must be
installed into terminal 1.
Don 7-73281 Issued 1-00
FORWARD/NEUTRAL/REVERSE OPERATOR SEAT SWITCH

m
co
s.
l og
ta
ca
ep

DI99A087
10006- 95

m
co
s.
l og
ta
ca
ep

DI99A086

NOTE 5: Grey relays are resistor protected and Black relays are diode suppressed. Black diode
suppressed relays MUST be grounded through terminal 2 and switched through terminal 1. Early
tractors equipped with grey resistor protected relays are grounded through terminal 1. Later tractors
with grey resistor protected relays are grounded through terminal 2.
IMPORTANT: If a Grey resistor protected relay is to be replaced, it MUST be replaced with a Black
diode suppressed relay. In may be necessary to change terminals 1 and 2 in the relay terminal block.
The Brown chassis ground wire must be installed into terminal 2 and the relay switching wire must be
installed into terminal 1.