0% found this document useful (0 votes)
36 views52 pages

UlEPL Catalouge 020418

The document discusses industrial communication products from UL Group including protocol converters, media converters, Ethernet, wireless, Ethernet accessories, Ethernet diagnostics tools, industrial IoT solutions, open source industrial PCs, embedded solutions, fibre optics, Profibus, Profinet, CANbus, and distributed fieldbus I/O systems.

Uploaded by

Juan Nuñez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views52 pages

UlEPL Catalouge 020418

The document discusses industrial communication products from UL Group including protocol converters, media converters, Ethernet, wireless, Ethernet accessories, Ethernet diagnostics tools, industrial IoT solutions, open source industrial PCs, embedded solutions, fibre optics, Profibus, Profinet, CANbus, and distributed fieldbus I/O systems.

Uploaded by

Juan Nuñez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 52

Industrial Communication

UL Electrodevices Pvt. Ltd.


www.ulepl.com
Vision Mission Philosophy
To the customer with innovative To create extraordinary We, at UL Group have today created
solutions as the most dependable and growth through multiplying an identity out of simplifying the
respected VALUE ADDED PARTNER factors like: technological maze for our clients.
and, be equally responsible towards } Innovations Our use of in-depth analysis, latest
our employees, associates and most } Value Additions technolgies and industry insight
importantly, society. } Forward Integration have earned us the recognition of a
} Expertise & Swift company that believes in finding
} Execution answers that are innovative, cuts
through the myriad processes and
helps our clients in attuning results
in a faster and smarter manner.
No wonder, they too are echoing our
belief: Keep simplifying, Keep
evolving
Industrial Communication
UL Group, a recognized supplier in the Industrial Automation
& Communication field, offers a comprehensive portfolio of
Industrial communication Products, Solutions and Services.
Index
One can notice that any Automation solution today, unlike
Protocol Converter......................... 4 - 10
yester-years, has communication networking as a major
Media Converter............................. 11 - 14 building block. Then comes the world-class engineering
practices and of course the conventional automation
Ethernet......................................... 15 -19 technologies. UL Group has been one of very few of those
companies in the field to understand this subtle but critical
Wireless......................................... 20 - 22
evolution in Industry. This gave us the impetus to develop as
Ethernet & Wireless Accessories... 23 contemporary automation service providers of today.

Ethernet Diagnostics tool We first put all our energies to emerge as leading experts in
& PLC Analyzer Solutions............... 24
Industrial communication of the Field-bus Technology,
Industrial IoT Solutions.................. 25 - 27 Ethernet, Fiber Optics & Wireless, UL Group is at forefront.
With their parallel efforts in acquiring expertise in world class
Open Source Industrial PC ............ 28 engineering & automation technologies, has came to be
known as a company with wholesome & latest automation
Embedded Solutions..................... 29
services .UL Group now proudly announce their unique ACE
Fibre Optic .................................... 30 - 31 positioning as UL-ACE, ACE is Automation Technologies
combined with expert Communication technologies and
PROFIBUS...................................... 32 - 41 world class Engineering practices for today's industrial
environment. UL now works totally around this vision.
PROFINET....................................... 42 - 44

CANBUS......................................... 45 Our basic concept as solution partner, providing a


comprehensive & well-matched product range with which
Distributed Field bus I/O System... 46 we can simplify the complex requirements with our
innovative & customized solutions for our customers.
Component For S7......................... 47 - 50

The close relationship with our trusted partners & in depth


knowledge of our Technical Team, allows UL GROUP to
continuously improve & develop fitting solutions for complex
Industrial Communication need for almost every application.

www.ulepl.com 3
Any Protocol
Any Media
All From One

Fiber Optics Modbus TCP Ethernet/IP Ethernet TCP/OPC

Profibus Serial RS232/485 DeviceNet Wireless

www.ulepl.com 4
Protocol Converter
Communicator
} Certified and proven Communicator family
connecting automation devices via their Serial
interface RS -232/422/485/ASCII/Modbus
RTU/DF1/Customize Protocol To Fieldbus and
Industrial Ethernet protocols.
} Handy Save/Load function allows for a completed
configuration to be re-used for many other
installations
} Possibility to connect up-to 31 nodes via one
Communicator
APPLICATION EXAMPLE: SIGNAL DROP APPLICATION EXAMPLE: MULTI- DROP } Requires no hardware or software changes to be
made to the connected device
} Password protection prevents unauthorized
upload and download of configurations
} Compatible with PLC from leading manufacturers
such as Siemens, Rockwell, Schneider etc.
} Available in Profibus, Profinet, Device Net,
Ethernet/IP, Modbus TCP& many more
} Included “Anybus Configuration Manager” with
Flexible Serial frame building Capabilities
} Approved.

X-Gateways
} The X-gateway allows you to seamlessly inter- connect
PLC control systems and their connected devices
} The data transmission between the two networks is
completely transparent.
} Over 300 different network combination (Master,
slave, Adapter, I/O device, Server)
} Connects different PLC system (Siemens, Rockwell,
Schneider, Mitsubishi, Omron, Beckhoff )
} Max 512Bytes Of Input and 512 bytes of output data
} I/O data transfer with average through put between
network of 10-15 ms
} Configuration via USB using the included Anybus
Configuration Manager-No programming required
} IT functions such as dynamic WEB Server,
supporting downloadable customer specific web pages.
} Fast, dynamic transfer of Fieldbus data to e.g.
SCADA/HMI / Enterprise level systems based on
Microsoft Windows, via the included Anybus OPC
server
} Robust stand-alone housing for use in harsh industrial
environments
} Remote monitoring and diagnostic feature for most
Ethernet version Via an Integrated WEB Sever
} Anybus Master Configuration tool included free of
charge with a Profibus, Device Net or Ethernet/IP
Master/Scanner.
} Approved.

www.ulepl.com 5
Protocol Converter
IEC Gateway
} Enable easy remote control and management of
electrical systems
} Support IEC 61850 client/server, GOOSE, proxy
gateway, IEC 60870-5-104 client/server and
VHPready
} Provide Modbus-TCP client/server and Modbus-
RTU master/slave interfaces
} Enable SNMP, SNTP, and cloud connectivity
} Provide I/O, M-Bus, PROFIBUS, PROFINET and
EtherNet/IP interfaces
} Are safe – firewall, OpenVPN & password protection
} Support IEC 60870-5-104 redundancy acc.
edition 2 (Norwegian Convention)
} Approved.
BACnet Gateway
} Enables central control and supervision of Modbus devices
within Building Automation and HVAC applications
} Handles conversion between Modbus (RTU & TCP) and
BACnet (IP & MS/TP).
} BTL certification.
} Supports BACnet version 12.
} Manages Modbus TCP and Modbus RTU simultaneously.
} Connects up to 254 Modbus devices to BACnet (processing
up to 3000 Modbus registers).
} A simple yet powerful config tool allows commissioning,
debugging and troubleshooting.
} Import and export to Excel for further signal processing.
} Comes in a plastic housing that mounts on 35-mm DIN-rail.
} Configuration could be done through IP or USB port LED
indicators provide communication status on both the
Ethernet and serial ports.
} Approved.
IT/OT Gateways
} Enabling communication between the factory floor & IT systems.
} NET Bridge enables factory-floor data from PROFINET, ROFIBUS,
EthernNet/IP or EtherCAT to be presented to .NET applications.
} As a .NET programmer, you can get data directly from a PLC system
and use this data in applications for statistics, analysis or
maintenance.
} System for connecting one or multiplePLCs to IT/softwaresystems.
} Send and receive data from each side.
} PLC programmer is in full control – PLC access via fieldbus or Ethernet
slave interface.
} IT style interface: customized names, receive events and post
structured data via C# / .NET interface.
} Automated configuration – system generates fully customized C#
API and PLC configuration (GSDML etc.), with names and data types
according to parameter list agreed between software programmer
and PLC programmer.
} Configuration is stored in C# program on customer side. In the event
of a replaced gateway hardware, the system will automatically restore
the configuration onto the new hardware.
} Dual Port switched Ethernet allows daisy chaining on all Ethernet
ports.
} Robust design for optimized cabling, DIN-rail or wall mount options www.ulepl.com 6
Protocol Converter
Master Simulator
} The Master Simulator is an easy to use tool to test your
Profibus, DeviceNet, CANopen, profinet slave/adapter
} The user friendly application makes it easy to configuration,
initialize and communication with the slave/adapter devices.
} Easy-to-use test and diagnostics tool
} No programming required
} Auto-detects slaves/adapters (even when GSD/EDS file is not
available)
} It's ideal for test wiring for input and output
} No need of external power supply
} Ideal for portable usage with laptop and notebook
} RS232 adapter, serial cable, CD and Software for Profibus
DP/DPV1
} Serial USB adapter, CD and software for DeviceNet, CANopen
} Ethernet Cable & Software for Profinet.
} Certification CE, CULUS, ATEX/Haz.Loc, RoHS

Ethernet CC-Link IE PROFINET IRT


Anybus X-Gateway Ethernet/IP
MBTCP
PROFINET-IO POWERLINK EtherCAT
Field
PROFIBUS DeviceNet CANopen Modbus
CC Link J1939*** LONWorks
ControlNet
FIP Slave
Interbus Interbus Modbus PROFINET
(V2.3X) slave
selection matrix slave
slave
slave slave slave
slave**
Slave Slave Slave RTU slave Slave Slave Cu Slave Fo Plus Slave IRT slave Fo
Cu
PROFIBUS Master AB7800 B AB7629 B AB7646 B AB7521 B AB7696 B AB7953 B AB7801 B AB7802 B AB7807 B AB7808 B AB7810 B n.a. - n.a. - AB7803 C AB7804 C AB7805 C AB7806 C AB7809 C n.a. - AB7500 B

AB7916 B
DeviceNet Master AB7607*** C AB7630 B AB7647 B AB7522 B AB7697 B AB7955 B AB7663 B AB7811 B AB7816 B AB7817 B AB7819 B n.a. - n.a. - AB7812 C AB7813 C AB7814 C AB7815 C AB7818 C n.a. - AB7501 B
ASI Master AB7820 B AB7631 B AB7648 B n.a. - AB7698 B n.a. - AB7821 B AB7822 B AB7827 B AB7828 B AB7830 B n.a. - n.a. - AB7823 C AB7824 C AB7825 C AB7826 C AB7829 C n.a. - AB7502 B
Ethernet/IP Master AB7668 B AB7669 B AB7670 B AB7524 B AB7699 B AB7957 B AB7671 B AB7672 B AB7677 B AB7678 B AB7680 B n.a. - n.a. - AB7673 C AB7674 C AB7675 C AB7676 C AB7679 C n.a. - AB7503 B
CANopen Master AB7306 * AB7308 * AB7307 * n.a. - AB7300 * n.a. - AB7301 * AB7302 * AB7304 * AB7305 * n.a. - n.a. - n.a. - AB7303 * n.a. - n.a. - n.a. - n.a. - n.a. - AB7329 *
Modbus MBTCP Master AB9006 * AB9008 * AB9007 * n.a. - AB9000 * n.a. - AB9001 * AB9002 * AB9004 * AB9005 * AB9009 * n.a. - n.a. - AB9003 * n.a. - n.a. - n.a. - n.a. - n.a. - n.a. -
Ethernet/IP slave AB7831 A AB7632 A AB7649 A AB7525 A AB7682 A AB7956 A AB7832 A AB7833 A AB7838 A AB7839 A AB7841 A AB7665 A AB7842 C AB7834 C AB7835 C AB7836 C AB7837 C AB7840 C AB7980 C AB7504 A
Ethernet MBTCP slave AB7632 A AB7633 A AB7650 A AB7526 A AB7901 A AB7958 A AB7634 A AB7635 A AB7640 A AB7641 A AB7643 A AB7665 A AB7644 C AB7636 C AB7637 C AB7638 C AB7639 C AB7642 C AB7979 C AB7505 A
PROFINET IO slave AB7649 A AB7650 A AB7651 A n.a. - AB7684 A AB7954 A AB7652 A AB7653 A AB7658 A AB7659 A AB7661 A n.a. - AB7662 C AB7654 C AB7655 C AB7656 C AB7657 C AB7660 C n.a. - n.a. -
POWERLINK slave AB7525 A AB7526 A n.a. - AB7544 A AB7527 A AB7528 A AB7529 A AB7530 A AB7510 A AB7532 A AB7533 A n.a. - n.a. - AB7535 C n.a. - n.a. - n.a. - AB7539 C n.a. - AB7540 A
EtherCAT slave AB7682 A AB7901 A AB7684 A AB7527 A AB7900 A AB7961 A AB7685 A AB7686 A AB7691 A AB7692 A AB7694 A n.a. - AB7695 C AB7687 C AB7688 C AB7689 C AB7690 C AB7693 C AB7970 C AB7506 A
CC-Link IE Field slave** AB7956 A AB7958 A AB7954 A AB7528 A AB7961 A n.a. - AB7959 A AB7960 A AB7963 A AB7964 A n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - AB7507 A
PROFIBUS Slave AB7832 A AB7634 A AB7652 A AB7529 A AB7685 A AB7959 A AB7843 A AB7844 A AB7849 A AB7850 A AB7852 A AB7615 A AB7853 C AB7845 C AB7846 C AB7847 C AB7848 C AB7851 C AB7944 C AB7508 A
DeviceNet Slave AB7833 A AB7635 A AB7653 A AB7530 A AB7686 A AB7960 A AB7844 A AB7854 A AB7859 A AB7860 A AB7862 A n.a. - AB7863 C AB7855 C AB7856 C AB7857 C AB7858 C AB7861 C n.a. - AB7509 A
CANopen Slave AB7838 A AB7640 A AB7658 A AB7510 A AB7691 A AB7963 A AB7849 A AB7859 A AB7894 A AB7895 A AB7897 A n.a.
- AB7898 C AB7868 C AB7876 C AB7883 C AB7889 C AB7896 C AB7943 C AB7510 A
See
Modbus RTU slave AB7839 A AB7641 A AB7659 A AB7532 A AB7692 A AB7964 A AB7850 A AB7860 A AB7895 A AB7899 A AB7621 A AB7612 A AB7009 - AB7869 C AB7877 C AB7884 C AB7890 C AB7620 C n.a. - AB7511 A
CC Link slave AB7841 A AB7643 A AB7661 A AB7533 A AB7694 A n.a. - AB7852 A AB7862 A AB7897 A AB7621 A AB7626 A n.a. - AB7627 C AB7871 C AB7879 C AB7886 C AB7892 C AB7624 C n.a. - AB7512 A
J1939*** AB7665 A AB7665 A n.a. - n.a. - n.a. - n.a. - AB7615 A n.a. - n.a.
- AB7612 A n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. -
See
LONWorks AB7842 C AB7644 C AB7662 C n.a. - AB7695 C n.a. - AB7853 C AB7863 C AB7898 C AB7009 - AB7627 C n.a. - AB7628 C AB7872 C AB7880 C AB7887 C AB7893 C AB7625 C n.a. - AB7513 C
ControlNet Slave AB7834 C AB7636 C AB7654 C AB7535 C AB7687 C n.a. - AB7845 C AB7855 C AB7868 C AB7869 C AB7871 C n.a. - AB7872 C AB7864 C AB7865 C AB7866 C AB7867 C AB7870 C n.a. - AB7514 C
FIP Slave AB7835 C AB7637 C AB7655 C n.a. - AB7688 C n.a. - AB7846 C AB7856 C AB7876 C AB7877 C AB7879 C n.a. - AB7880 C AB7865 C AB7873 C AB7874 C AB7875 C AB7878 C n.a. - AB7515 C
Interbus Slave Cu AB7836 C AB7638 C AB7656 C n.a. - AB7689 C n.a. - AB7847 C AB7857 C AB7883 C AB7884 C AB7886 C n.a. - AB7887 C AB7866 C AB7874 C AB7881 C AB7882 C AB7885 C n.a. - AB7516 C
Interbus Slave Fo AB7837 C AB7639 C AB7657 C n.a. - AB7690 C n.a. - AB7848 C AB7858 C AB7889 C AB7890 C AB7892 C n.a. - AB7893 C AB7867 C AB7875 C AB7882 C AB7888 C AB7891 C n.a. - AB7517 C
Modbus plus AB7840 C AB7642 C AB7660 C AB7539 C AB7693 C n.a. - AB7851 C AB7861 C AB7896 C AB7620 C AB7624 C n.a. - AB7625 C AB7870 C AB7878 C AB7885 C AB7891 C AB7623 C n.a. - AB7518 C
PROFINET IRT slave Fo AB7980 C AB7979 C n.a. - n.a. - AB7970 C n.a. - AB7944 C n.a. n.a. AB7943 C n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - AB7972 C n.a. -
PROFINET IRT (2.3X) slave Cu AB7504 A AB7505 A n.a. - AB7540 A AB7506 A AB7507 A AB7508 A AB7509 A AB7510 A AB7511 A AB7512 A n.a. - AB7513 C AB7514 C AB7515 C AB7516 C AB7517 C AB7518 C n.a. - AB7519 A
The abbreviation "n.a." indicates that the product is currently not available in the standard Anybus product offer from HMS.

www.ulepl.com 7
Protocol Converter
Modular Gateway Solution
} Modular Gateway enables continuous and reliable
communication between different networks and
systems.
} Diversely combinable with different protocols
} Simple plug-in connection for bus modules by means
of plug-in jumper
} Customized solutions are also possible.
} The Modular Gateways are equipped with an
integrated web server; program parts are updated via
FTP server.
} Connection for power supply via screw-type terminal
(optional: spring-loaded terminal)
} Max. power < 3 Watts
} Throughput max. 512 bytes
} Installation on a DIN rail

Network A Network B

Gateway for Process Automation


} DIN rail mounted Profibus DP and PA gateways for
measurement, detector and analyzer devices with
HART® and Modbus® RTU interfaces.
} Suitable for system integrators wishing to incorporate
legacy equipment into their designs and instrument
manufacturers wishing to extend their market for
existing products.
} Module width 23 mm.
} No special programming is required to set up the
device. · The world-wide provider of fieldbus connectivity
} Includes a master in order to communicate with solutions for process automation
instruments. · Modbus RTU to HART converter
} Any communication problem will be reported in the · HART to Profibus PA DIN rail mounted gateway
Diagnostics message. · HART to Profibus DP DIN rail mounted gateway
· Modbus to Profibus PA DIN rail mounted gateway
· Modbus to Profibus DP DIN rail mounted gateway
· HART to FOUNDATION DIN rail mounted gateway
· Modbus RTU to Foundation DIN rail mounted gateway

www.ulepl.com 8
Protocol Converter
RS 232 / RS 485 to Profibus
DP Gateway
} Intelligent, low-cost
} User friendly.
} Serial configuration tool not required.
} All connections are by D-SUB connectors
} The PROFIBUS station address is set via coding switches.
} Hat Rail installation.
} Configured as Profibus Slave using available GSD File.
} Possible to integrate devices with MODBUS ASCII/RTU
interface, typically they will only have an RS232, RS422 or
RS485 interface.
} Supported PROFIBUS Protocol Versions: DP Slave
} Interfaces: Serial Profibus RS232/422/485/MODBUS
ASCII/RTU RS485 (isolated)
} Baud Rates: 9.6 To 12 Mbps
} Power Supply: 24 V DC
Fieldbus Network Link of
Profibus & Ethernet
The compact 24 Volt hat rail module The small sized,
Ethernet based hat rail module allows the connection to all
copper based PROFIBUS DP networks.
} Network Configurator (CNC) for the integration of FNL in
your network
} PROFIBUS configuration tool CONFIGURATOR III with
extensive download, analysis and control functions
} Programming interface: The TCP/IP socket interface
provides transparent exchange of the DP Slaves' process
and diagnostic data as well as all DP/DPV1 Master class
1/2 and DP Slave services
} No more hardware/driver installation with its typical
related problems
} Access to the respective fieldbus from any arbitrary
network PC
} Up-to-date technologies, like internet, e-mail etc. can be
used in the process control level Fieldbus Network Link of
} Add-on software: OPC Server, FDT 1.2 Communication
DTM, LabVIEW™ Driver for FNL Profibus & Profinet
The FNL Proxy PN/PB integrates PROFIBUS DP segments in
PROFINET IO. The 24 Volt hat rail module contains one
PROFIBUS DP interface, four PROFINET IO RT interfaces as
well as one RS232 service interface for commissioning and
diagnostics.

The proxy integrates both existing and new PROFIBUS DP


devices without any modification or adaptation into a
PROFINET IO network.

} Conforms to the specification of the PROFIBUS User


Group according to the modular mapping procedure
} Full graphical PROFIBUS configuration tool
} SNMP diagnostics
} TFTP based firmware update
www.ulepl.com 9
Protocol Converter
Gateway for Fieldbus Communication
over Ethernet
} The Ethernet module isNet Lite is the head module of every gateway solution
based in the product family isNet Line.
} In combination with different fieldbus communication modules the
isNet Lite allows direct access from Ethernet to any fieldbus
instrument.
} isNet Lite is suitable for tasks like remote diagnosis, remote
maintenance or remote parameterisation as well as PROFINET gateway or
Modbus TCP gateway remote monitoring and control

PROFIBUS DP Ethernet Gateway


} With the isNet DP module the main module isNet Lite can be extended
to work as a PROFIBUS DP (DP/V0 and DP/V1) Ethernet Gateway.
} The isNet DP modules are available as one and two channel version.
} The main module can be enhanced with a maximum of 5 PROFIBUS
modules, so up to ten PROFIBUS segments can be accessed from the
main module.
} The PROFIBUS channels are galvanically isolated, at the 2 channel
version each channel is isolated separately.
} The modules are operated via the isPro CommDTM from Thorsis
Technologies. The DTM is compliant to the FDT 1.2.1specification and
integrates the gateway into every FDT-frame application.
HART Ethernet Gateway
} Main module isNet Lite can be extended to work as an HART-Ethernet gateway.
} The HART Ethernet gateway is an up-to-date option to replace the widely used
RS485 HART multiplexer solutions as it enables the direct connection to the
existing data network of a plant.
} The isNet H@rt modules are equipped with either four (single width) or eight
(double width) channels. Up to five HART modules can be connected to the main
module, so a maximum of 40 HART channels can be operated in parallel.
} Access to the HART network is achieved by 8 plug-in screw-type terminals.
} With the isNet H@rt CommDTM, the modules can be integrated in your FDT
framework. Due to support of the HART over IP protocol, the isNet H@rt can also
be used with the HCF OPC server.

FOUNDATION Fieldbus Ethernet Gateway


} To access FOUNDATION Fieldbus field devices, the main module isNet Lite can be
expanded with a FF linkmaster module.
} This module is available as 1-channel, 2 channel or 4–channel version.
} Furthermore for each channel the modules include a voltage supply for the
connected field devices, so that external supply voltage sources and power
conditioners can be omitted. Of course, the connection to externally
supplied FF – network segments is also possible.
} For the modules a free FDT 1.2–compatible communication DTM is available which
allows access to the connected FF field devices in FDT frame applications
like Pactware.

Module with Digital Inputs and Outputs


} The isNet DIO module is an extension module for the product family isNet Line with digital
inputs and outputs.
} The module is available with 4 channels or with 8 channels.
} Every channel consists of a 4 oin screw type terminal with one input and one output per channel.
} It is IEC 61131 conform and can sense inputs, that represent the state of engines, valves and
other equipment with binary signals.
} Also it can switch pumps, valves, heaters, fans or other industrial equipment with its outputs.
} In combination with other fieldbus specific modules the isNet DIO can extend every fieldbus
with digital I/O capability.
www.ulepl.com 10
Media Converter
PROFIBUS to FO
} Point to point, Bus, Star & Ring system Profibus
} POF, HCS (PCF), multimode, Single-Mode
} Optically redundant Profibus
} Max data rate upto 12 Mbps
} FiberView option for diagnostic.

RS232/422/485 - FO
} Point to point, Bus, Star & Ring system on
RS232/RS485/RsS422
} POF, HCS (PCF), multimode, Single-Mode
} Protocol transparency
} Support Modbus and Modbus Plus
} FiberView option for diagnostic.

CAN/DeviceNet - FO
} Point to point, Bus or Star system, Ring
} CAN, DeviceNet
} Optically redundant CAN,DeviceNet
} POF, HCS (PCF), multimode, Single-Mode
} DIN rail mounting
} FiberView option for diagnostic.

Analog-Digital to FO
} Analogue signals 0-10V or 0-20mA
} Digital signals: 12-24VDC bi-directional or relay contacts
} Point to point system
} POF, HCS (PCF), multimode, Single-Mode
} DIN rail mounting

www.ulepl.com 11
Media Converter
Serial to FO
} Supports multiple baud rate and multiple data format
} Support Full-Duplex transmission for RS-232/RS-422
} Supports RS-232/422/485,Support Modbus protocol
} Auto switching baud rate from 50~921.6 Kbps
} Power requirement from +12 ~48 VDC
} Provided DIP-Switch to setting function
} Support Single-Mode & Multimode
} Dual power supply design for power redundancy
} Secured management by HTTPS
} High reliability and rigid IP-30 metal housing
} DIN-Rail and wall mounting enabled
} Approved.

Ethernet to FO
} Each slot support 10/100/1000 Base T(X) auto-
negotiation and auto-MDI/MDI-X
} Support Single-Mode & Multimode
} Dual power supply design for power redundancy
} SFP port support full duplex operation
} Secured management by HTTPS
} High reliability and rigid IP-30 metal housing
} DIN-Rail and wall mounting enabled
} Approved.

Serial to Serial
Rs232 to 422/485 with
3KV isolation serial converter
} Support multiple baud rate and multiple data format
} Support highest power output
} Auto Hardware Direction Control for RS-485
} Auto switching baud rate from 300 ~ 115200 bps
} Power requirements from +9 ~ 30 VDC
} ABS with captive mounting hardware design
} DIN-Rail and wall mounting enabled
} Approved.

Serial to Serial
RS422/485 to 422/485 with
3KV isolation serial converter
} Automatic internal RS-422/485 bus supervision
} No external flow control signals required for RS-485
} Serial type support auto detect and switch
} Supported baud rate up to 115.2Kbps
} Reach distance up to 4000 feet (1200m)
} Support multiple baud rate and multiple data format
} Reserved space for termination resistors (R8,R9)
} Approved.

www.ulepl.com 12
Media Converter
Serial to Ethernet
} Operating Modes: Virtual Com, Serial Tunnel, TCP Server, TCP Client,
UDP, Modbus Gateway
} Redundant multiple host devices:5 host devices: Virtual COM, TCP
Server, TCP Client mode; 4 IP ranges: UDP
} Support Modbus Gateway : Modbus TCP, Modbus RTU, Modbus ASCII
} RS-232/422/485 in DB9 connectivity available
} Ethernet switch mode enable Daisy Chain
} Support Gigabit Ethernet ports for high speed data transmission
} Security: SSL data encryption; secured management by HTTPS & SSH
} Supports PoE P.D. port features
} Event Warning by Syslog, SNMP trap, Relay & Beeper
} Configurable by Web-based & Windows utility (DS-Tool)
} Available in 4 to 18 ports
} Approved.

Serial to USB
} Fully compliant with USB 2.0 specifications
} Support Full-Duplex transmission for RS-232/RS-422
} RS-232/RS-422 support RTS/CTS handshake signals
} Transient suppression on RS-485 data lines
} Auto detect and switching for USB to RS-232/422/485
} Auto detect and switching baud rate up to 115.2Kbps
} Serial port with 3KV isolation
} USB bus powered with ultra low power consumption
} DIN-Rail and wall mounting enabled
} Available in 1 to 8 ports
} Approved.

Profibus to USB
} Our mobile USB adapter allows quick connection to a
PROFIBUS network.
} Tasks such as parameterization or diagnosis can be
made on-site with a laptop.
} The device contains a PROFIBUS master, which
controls the protocols DP and DP / V1, but is usable
just as good for less common protocols such as
PROFIBUS FMS.
} Mobile set up and configuration of field devices
} Up to 16 PROFIBUS USB adapters connected to one
PC for data access to connected PROFIBUS slaves
} with the supplied test software you can search for
connected PROFIBUS slaves (Live list)
} Available software: isPro CommDTM (FDT), isPro
MultiServer (OPC)
} Driver Software: XP, Vista, 7, 8, 10

www.ulepl.com 13
Media Converter
Hart to USB
} The commissioning of HART devices is easier than ever by
using the HART-USB adapters.
} The affordable USB devices can easily be integrated
into common configuration software via a virtual COM port.
} Mobile set up and configuration of field devices
} Use in hazardous areas we provide an intrinsic safe, Galvanic
decoupling
} Communication DTM for use of the interface in FDT frame
applications
} Driver software: Windows XP, Vista, 7, 8, 10
} Compatible with: HFC OPC Server (HART Communication
Foundation), Simatic PDM (all versions), FDT frame
applications
} Available software: isH@RT Device DTM, isHRT CommDTM
(FDT 1.2.1)
CAN to USB
} Our CAN - components enable the mobile setup,
configuration& monitoring of decentralized automation
solutions in the fields of mechanical engineering,
automotive, medical and building automation.
} The integrated optocoupler provide galvanic isolation of
the CAN network
} isCAN USB interface into customer specific systems as
hardware is also available as a compact PCB.
} Labview is supported by a Labview driver package
} Driver software: Windows XP, Vista, 7, 8, 10
} Available software: isCAN/CANopen Comm DTM,
isCAN/CANopen Server (OPC)
Foundation Fieldbus to USB
} The USB adapter isFF USB provides a quick and easy
way to access to FOUNDATION Fieldbus field devices.
} A special feature is the ability to supply a single
connected field device directly from the USB device - a
feature which helps especially in the exchange of field
devices, if a replacement device must be parameterised
before installation in the plant.
} The included communication DTM allows easy access
to the parameters of the field devices.
} Driver software: Windows XP, Windows 7, 8, 10
} Available software: FDT 1.2 (isFF CommDTM)
DeviceNet to USB
} For the access on a DeviceNet network Thorsis
Technologies offers an USB adapter, which can be
adapted by an open API for customization of existing
applications.
} The functionality as Explicit Messaging Server is thus
feasible as well as the functionality as Explicit
messaging client or the process data exchange via
“Poll”, “Bit Strobe” “Cyclic” and “Change of State”
connections.
} Driver software: Windows XP, Vista, 7, 8, 10
} Available software: isCAN/CANopen Comm DTM,
IsCAN/CANopen Server (OPC)
www.ulepl.com 14
Ethernet
Unmanaged Ethernet Switches
} Compact IEEE 802.3 Layer 2 industrial switches
} Plug-and-play functionality.
} Support store and forward transmission
} Duplex and cable sensing
} Support auto-negotiation and auto MDI/MDI-X
} Hardened for the toughest applications
} Dual Redundant Power Inputs available
} SM, MM FO, Giga Ports available
} Din-Rail, Wall, Rack Mounting available
} Available in 5 to 26 ports
} Approved.

Managed Ethernet Switches


} Layer 2 and Layer 3 Ethernet switches
} Fastest Redundant Ethernet Ring-(recovery time
< 10ms over 250 units of connection)
} Multiple Redundant Ethernet technology RSTP/STP
} Web-based, Telnet, Console (CLI), and Windows
utility (Open-Vision) configuration
} Rugged, enterprise-class networking
} Advanced security features
} Dual Redundant Power Inputs available
} SM, MM FO, Giga Ports available
} Din-Rail, Wall, Rack Mounting available
} Available in 5 to 28 ports
} Approved.

Power Over Ethernet (PoE)


} Layer 2 and Layer 3 Industrial power over Ethernet (POE)
& POE++
} Switches, Injectors and Splitters
} Transmits power and data over Ethernet networks
} Recovery time <30ms over 250 units of connection
} MSTP (RSTP, STP compatible) for Ethernet redundancy
} P.S.E fully compliant with IEEE 802.3at standard, provides
up to 30W per port
} Supports Max PoE output up-to 720 Watts
} Web-based, Telnet, Console (CLI) and Windows utility
(Open-Vision) configuration
} Dual Redundant Power Inputs available
} Managed, Unmanaged, SM, MM FO, Giga Ports available
} Din-Rail, Wall, Rack Mounting available
} Available in 2 to 28 ports
} Approved.

www.ulepl.com 15
Ethernet
Industrial Solutions -
Power Sub Station (IEC-61850)
} Fully compliant with the requirement of IEC 61850-3 & IEEE 1613
} IEEE 802.3 Layer-2, Layer-3 industrial switches
} Support IEEE 802.3azEnergy-Efficient Ethernet technology
} Ultimate Port Flexibility
} Fastest Redundant Ethernet Ring-(recovery time < 10ms over 250
units of connection)
} Multiple Redundant Ethernet technology RSTP/STP/MSTP
} Web-based, Telnet, Console (CLI) and Windows utility
(Open-Vision) configuration
} Rugged, enterprise-class networking
} Advanced security features
} Powerful Management & Monitoring
} Din-Rail, Wall, Rack Mounting available
} Available in Ethernet to fiber Media Converter and Supports full/half
duplex operation
} Support PTP Client (Precision Time Protocol) clock synchronization
} SM, MM FO, Giga Ports available.
} Available in 2 to 28 ports
} Approved.

Ethernet Extender
} Extend Ethernet distance up to 300m (984 feet) over UTP
cable or up to 200m (656 feet) over 24AWG none-UTP cable
} Support 2/4/8-wired auto detecting transmission
} Provided DIP-Switch to selecting Auto/Manual mode for
Master/Slave setting
} Supports Auto mode to auto-negotiation for master/slave
mode switching
} Ethernet port support full/half duplex operation
} Ethernet port support Auto MDI/MDI-X switching function
} Redundant 12~48VDC power inputs with Terminal Block
} DIN-Rail and wall mounting enabled
} Approved.

www.ulepl.com 16
Ethernet
Switches
Industrial Solutions - Railway } EN50155-compliant Ethernet switch for rolling stock
(En50155) application
} World's fastest Redundant Ethernet Ring: O-Ring
(recovery time < 10ms over 250 units of connection)
} Open-Ring support the other vendor's ring technology in
open architecture
} STP/RSTP/MSTP supported
} Support PTP Client (Precision Time Protocol) clock
synchronization
} Advance security features
} Available with PoE features
} Windows utility (Open-Vision) support centralized
management and configurable by Web-based, Telnet,
and Console (CLI)
} Event notification through Syslog, Email, SNMP trap, and
Relay Output
} M12 connectors to guarantee reliable operation against
environmental disturbances
} Wall mounting enabled
Wireless
} EN50155-compliant wireless access point for rolling stock
application
} High Speed Air Connectivity: WLAN interface support up
to 300 Mbps link speed
} H i g h l y S e c u r i t y C a p a b i l i t y : W E P / W PA / W PA -
PSK(TKIP, AES)/WPA2/WPA2-PSK(TKIP, AES)/802.1X
Authentication supported
} Support X-Roaming < 60ms
} Support external SMA antenna installation
} Support AP/Client /Bridge /AP-Client Mode
} Secured Management by HTTPS
} Event Warning by Syslog, Email, SNMP Trap and Relay
output
} M12 connectors to guarantee reliable operation against
environmental disturbances
} Wall-mount enabled
} Approved.

www.ulepl.com 17
Ethernet
Industrial Solutions -
Oil & Gas (C1D2/ATEX)
} C1D2 and ATEX compliant for harsh industrial
environments application
} World's fastest Redundant Ethernet Ring: O-Ring
(recovery time < 10ms over 250 units of connection)
} Open-Ring support the other vendor's ring technology in
open architecture
} O-Chain allow multiple redundant network rings
} Support standard IEC 62439-2 MRP (Media Redundancy
Protocol) function
} STP/RSTP:2004/MSTP supported
} Support Auto Negotiation and Store-Forward transmission
} Advance security features
} Windows utility (Open-Vision) support centralized
management and configurable by Web-based ,Telnet,
Console (CLI)
} Support Gigabit combo ports
} Din-Rail, Wall Mounting available
} SM, MM FO, Giga Ports available
} Available in 8 to 18 ports
} Approved.

Bypass Switch
} Hardware Bypass redundancy technology naturally
and effectively avoids single-point power failure in
daisy chain topology or multi-point failures
} Support 100M/1G/10G optical bypass function of 2
port duplex or 4 port simplex fiber connection
} Different models supported for multi-mode or
single-mode optical fiber
} Low insertions loss
} Throughput not affected and no extra delay
} Bypass switching time < 10ms
} Dual wide-range power inputs: 12~48VD
} Available Copper & FO
} DIN-Rail/Wall-mount/Desktop Mounting
} Approved.
www.ulepl.com 18
Ethernet
Industrial Ethernet Bridge & Firewall
} Integration of machine networks into the higher-level plant
network
} Bridge function for identical IP address ranges
} NAT (Basic NAT, NAPT and port forwarding)
} Access restriction through packet filters: IPV4 addresses,
protocol (TCP/UDP), ports, MAC addresses
} Reduction of the network load through the filtering of
broadcasts and multi-casts
} Quick and easy configuration via a responsive web interface
} Static routes to other networks
} Reporting of events to a Syslog server
} Import and export of the configuration
} Industry-compatible design for mounting on a DIN rail

Network Management Software -


Open Vision
} A powerful management utility is important for
administrators to monitor and manage all devices in a
local network.
} For the four basic functions – Centralized management /
Visualized management / Complete monitor / Early
system Alarms
} IP setting group wizard, firmware upgrade group wizard,
and redundant ring (O-Ring) setting wizard
} Draw the whole network topology automatically and path
management available
} Devices could be grouped and managed by different IP
ranges in ORing Topology View
} Oring MAP technology could be showed network device
locate by Google MAP
} IP scan to detect all of the IP-based devices in the local
network
} No limitation on the amount of devices to be monitored
} The health status of connections is automatically
checked
www.ulepl.com 19
Wireless
Industrial Cellular Router
} High Speed Air Connectivity: WLAN interface support up to
300Mbps link speed
} Support 10/100/1000Base-T(X) port and 2 SIM card slot
} Support dual 4G/3.5G/3G dial up backup and load balance
} EN50155-compliant available
} Serial communication via RS232/RS422/RS485 interface
} Provide HNAT enhance LAN to WAN routing performance
} Highly Security Capability: WEP/WPA/WPA-PSK(TKIP,AES)/
WPA2/WPA2-PSK(TKIP,AES)/802.1X Authentication
supported.
} Secured Management by HTTPs
} Integrated firewall
} Support STP (802.1D) for wireless redundancy
} Various kind of WAN Connection Type supported:
Dynamic/Static IP, PPPoE, Modem/Dial Up
} Support VPN for secured network connection (Open VPN ,
PPTP VPN, IPSEC VPN)
} Support NAT Setting (Virtual Server, Port Trigger, DMZ, UPnP)
} Modbus Protocol conversion between ModbusTCP and
Modbus RTU
} Event warning by Syslog, Email, SNMPTrap, Relay output
} 1KV isolation for PoE P.D. port
} Rigid IP-30/IP67 housing design
} DIN-Rail and Wall-mount enabled
} Approved.

www.ulepl.com 20
Wireless
Industrial Access Point
} High Speed Air Connectivity: Dual RF in IEEE 802.11a/b/g/n
WLAN interface support up to 300Mbps link speed
} Supports Dual-Band WLAN 2.4/5 Ghz frequency
} Highly Security Capability: WEP/WPA/WPA-PSK(TKIP, AES)/
WPA2/WPA2-PSK(TKIP, AES)/802.1X
} Serial communication via RS232/RS422/RS485 interface
} Support Dual AP/Dual Client /Bridge /AP-Client Mode
} Ethernet interface: 10/100/1000 BASE-T with automatic
MDI/MDIX cross-over
} Use with point-to-point and multi-points wireless Industrial
Ethernet installations through hazardous or hard-to-reach
locations
} EN50155-compliant available
} Authentication supported
} Support Long Distance Air Connectivity
} Support X-Roaming < 60 ms
} Support wireless load balance
} Support external SMA / N-Type antenna Directional / Omni
directional installation
} Support MAC/IP/Port Filter
} Provide Digital Input and Digital Output
} Wireless connecting status monitoring
} Secured Management by HTTPS
} 1KV isolation for PoE P.D.
} Event Warning by Syslog, Email, SNMP Trap & Relay output
} Rugged IP30/ IP67 rated industrial design
} Approved.

www.ulepl.com 21
Wireless
Wireless Bolt - Ethernet
} Configure or troubleshoot industrial machinery over a wireless network
} Increase flexibility and mobility.
} Eliminate expensive fixed HMI's by using a laptop, tablet or smart phone
} Connect to moving field equipment such as an AGV's (Automated Guided
Vehicles)
} Connect to a Cloud Service of your choice or get live data & integrate it
into a SCADA system
} Supports Ethernet and protocols such as: BACnet/IP, EtherNet/IP,
Modbus-TCP, PROFINET, TCP/UDP
} Operates as an Access point or Client
} Connects up to 7 Slaves as an Access point
} Max throughput: 20 Mbps
} Max Range: 100 meters
} Uses Dual-band Wi-Fi 2.4/5 GHz to connect easier and identify
interference-free channels
} All-in-one package: Connector, communication processor & integrated
antenna in the same unit
} Includes a configurable Digital Input to control e.g. roaming behavior.
Max. 3m signal cable
} Uses the ARM mbed 3.0 IoT Device Platform.
} Security features for a secure industrial operation
} Starterkit available
} Approved.

Wireless Bridge-Ethernet & Serial


Modo Bridge (Punto a Punto) Modo Access Point (Multipunto)
} Use with point-to-point wireless Industrial Ethernet
installations through hazardous or hard-to-reach locations
} Use as an Access Point for up to seven clients
} Eliminates the need for expensive or maintenance-heavy
cabling
} Bridges TCP/IP Ethernet and protocols such as: BACnet/IP,
EtherNet/IP, Modbus-TCP and PROFINET
} For Serial interface connects up to 7 slaves with a serial
RS-232/422/485 interface via Bluetooth
} Includes Wireless Multidrop™ with simultaneous
connections to both Bluetooth devices
} Unique method to handle interference disturbances
} Max range for Ethernet Module upto 400 meters and for
Serial upto 300 meters.
} Full compatibility with Wireless Bolt - a wireless product for
machine mounting
} Easy configuration via push button or web interface
} Advanced configuration with AT commands
} Conforms to wireless standards worldwide
} Compatible with PROFIsafe requirements.
} Conforms to wireless standards used in Europe, USA,
Canada and Japan
} Rugged IP65 rated industrial design
} Security features for a secure industrial operation
} Starter kit available
} Approved.
www.ulepl.com 22
Ethernet & Wireless Accessories
Ethernet Cables
} Cat.5E,Cat6 ,Cat7 Shielded RJ45, SFTP, SSTP
} Alternating bending test (with load) according to VDE0472 T603
} Resistant to mineral oil, ASTM oil and UV radiation, highly
abrasion-resistant
} Suitable for outdoor areas, but not for laying directly in earth
} Wiring according to EIA/TIA 568B 1:1 or crossover
} Moulded sleeve with length imprint on sleeve
} Various colours are available grey, green, blue, yellow, red, black
} Lengths: 0.5m; 1m; 2m; 3m; 5m; 7.5m; 10m; 15m; 20m; 25m;
30m available.
} Other lengths are deliverable upon request
} Halogen-free, Fully plug compatible to IEC 60603-7

Ethernet Connectors
} Industrial connector RJ45 IDC quick-connect technology,
no tools required Category 5e / 6A
} Industrial connector RJ45 Version V6; category 5e IDC
quick-connect technology
} Module holder, RJ45, female / IDC For TS35 DIN rail
Category 6
} RJ45 panel connector for front installation 22.5mm
female/female 1:1, Category 5e/6
} Control cabinet bushing M12 - RJ45 female/female
1:1 Category 5e
} Cable gland, RJ45, female / IDC Version V6 Category 5e /
6, IDC, no tools required
} Cable gland RJ45 female / Version V6 Category 5e
} Supports Profinet, SERCOS 3, EtherCAT, Ethernet/IP,
Powerlink, Modbu-TCP many-more.

Wireless Accessories
RF Adapter
} RF Right Angle Adapter, SMA Female to SMA Male connector
} RF Adapter, RP SMA Female to SMA Male connector
} RF Right Angle Adapter, RP-SMA Female to RP-SMA Male connector
} RF Adapter, SMA Male to N Female connector
} RF Adapter, RP-SMA Male to N Female connector
} RF Adapter, SMA Male to N type Male connector
RF Antenna Base
} RP-SMA Female magnetic antenna Base with cable length 1.5m and RP-SMA Male connector
} RP-SMA Female magnetic antenna Base with cable length 10m and RP-SMA Male connector
} N Female magnetic antenna base with cable length 10m and RP-SMA Male connector
} N Female magnetic antenna base with cable length 1.5m and RP-SMA Male connector
RF Cable
} Low loss RF Cable, Cable length 1.5/10m, , N Female to RP-MA Male connector
} Low loss RF Cable, Cable length 1.5/10m, N Male to N Male connector
} Low loss RF Cable, Cable length 0.5/1.5/10m, N Male to N Male connector
} Low loss RF Cable, Cable length 0.5/1.5/10m, N Male to RP-SMA Male connector
} Low loss RF Cable, Cable length 1.5m, SMA Female to RP-SMA Male connector
} Low loss RF Cable, Cable length 10m, RP-SMA Female to RP-SMA Male connector
} Low loss RF Cable, Cable length 1.5m, SMA Male to RP-SMA Male connector
Antenna
} Rooftop/Outdoor High Performance Omni Antenna , 3G/4G, GPS applications, 5dBi max,
N Female connector
} Outdoor High-gain Panel Antenna, 2.4GHz, 12dbi max., N Female connector
} Omni-directional High-gain Antenna, 2.4GHz, 7dBi max, N Male connector

www.ulepl.com 23
Ethernet Diagnostics tool
& PLC Analyzer Solutions
Ethernet Diagnostics - Atlas

Position in the network

Features Atlas
} Customizable dashboard
Users Your benefits } Topology
} Maintenance & Support } Network oversight } Universe & tree structured networks
} Plant Manager } Easy to install via DIN rail } Q-Factor
} IT Professional } No software required } Device list
} Network Engineer } Compact & robust construction } Traffic light
} Operator } Ease of use } Alarm notifications
} 24/7 available } Approved.

PLC Analyzer Software


} Software tool for the manufacturing industry
for logic analysis and data recording of PLCs.
} It helps troubleshoot problems in PLC logic or
equipment through easy data acquisition and
analysis in real time.
} With PLC-ANALYZER pro 5 you can see each
PLC signals bit for bit.
} You can analyse flags, counters, timers
whatever you want and display it to see the
time dependent behaviour of all and compare it
between.
} No additional hardware is necessary just use
the existing programming connection.

www.ulepl.com 24
Industrial IoT Solutions
Theme IoT Solution

Wireless Remote IO
} Support 2 Serial Ports for RS232/RS422/4W-
RS485/2W-RS485
} Support NB -IoT/CAT M1/CAT 1/ZigBee/BT
(BLE3.0)/LoRa ( by model)
} Support 4 Digital inputs (Dry/Wet) / 4 Digital outputs
(Sink)
} Support Data Log (SD card)
} Support Data Log
} Support Modbus protocol
} Support MQTT/COAP protocol
} Support GPS
} Support configuration via USB virtual com port
} 40 to 75°C wide operating temperature

www.ulepl.com 25
Industrial IoT Solutions
OR - Gate
} Standard product for variety meter application
} Support UART /TTL/RS-485
} Support Lora-WAN
} Support NB-IOT/CATM1 Band 3/Band 5/ Band 8 /
Band 20 / Band 28
} Support MQTT protocol
} Support Modbus Protocol
} Support Battery mode
} 40 to 750C wide operating temperature

Street Light Controller


} NB-IoT/LoRa/ZigBee module and antenna design
} NEMA ANSI C136.41 Standard
} Wide Temp: -20~600C
} MQTT and CoAP Protocol
} Power saving mode (Parameter Customize)
} Fault Detection
} Dimming
} Support Street Light Management System

IoT Applications

LoRa and Wifi Street Light Controller Sensor Gateway Application

www.ulepl.com 26
Industrial IoT Solutions
Ethernet Router
} Integrated firewall
} Digital inputs for establishing a connection and
issuing alarms
} USB-over-IP
} Space-saving compact size
} Integrated 4-port LAN switch
} Secure OpenVPN remote maintenance access via
myREX24 V2 portal
} Interface Variants: WiFi, LTE, 3G, WAN

WAN+ Analog Modem,


PROFIBUS/MPI, serial interface
} Integrated firewall
} Data server for data access to PLCs via RFC1006
(ISO on TCP), MPI, PROFIBUS, Modbus-TCP/RTU,
Allen Bradley, etc.
} Directly connect S7-MPI/PROFIBUS devices
} S7-MPI/PROFIBUS driver included
} Remote maintenance of PROFIBUS
(RS232/RS485) and Ethernet-compatible devices
(PROFINET-compatible)
} Serial-over-IP
} Secure OpenVPN remote maintenance access via
myREX24 V2 portal

Secure IoT remote maintenance access


Remote maintenance | Visualization | Alarming | Logging

www.ulepl.com 27
Open Source Industrial PC
Revolution Pi - Open Source Industrial PC
} Open, modular and inexpensive industrial PC based on the
established Raspberry Pi.
} Equipped with Raspberry Pi Compute Module, the base module
can, depending on requirements, be expanded seamlessly using
appropriate I/O modules and gateways.
} Installed in a DIN rail housing, the base module of the Revolution Pi
already has USB, Ethernet and HDMI connections.
} Modbus capabilities : Revolution Pi comes with master and slave
capability for the popular Modbus RTU and Modbus TCP network
protocols.

RevPi Core 3 RevPi Core


Processor : BCM2837 Processor : BCM2835
Clock rate : 1.2 Ghz Clock rate : 700 MHz
Number of cores : 4 2 types & Number of cores : 1
RAM : 1 GByte possibilities RAM : 500 Mbyte
eMMC Flash : 4 GByte eMMC Flash : 4 GByte

} To transform Revolution Pi into an industrial control unit, various digital I/O modules, amongst other things,
canbe connected to the base module RevPi Core.
} The I/O modules come in three versions :
1. connector with two rows of 14 pins each
2. 16 digital inputs
3. 16 digital outputs
} All versions have the same 28- pin I/O connector at the front.

Digital I/O modules Analog I/O module Fieldbus connection


(RevPi DIO with14 inputs and outputs) (RevPi Core 3 and RevPi AIO onDIN rail) (RevPi Gateways)

We currently offer gateways for the network protocols shown below :

www.ulepl.com 28
Embedded Solutions
IC Solutions
} Thanks to its compact size, the KUNBUS-IC is perfectly
suitable especially for small devices or for devices with little
space for the communication interface.
} The KUNBUS-IC modules allow your device to be
integrated into a corresponding network without major
development effort.
} They contain all components required, such as bus drivers,
Optocouplers, transducers, microcontrollers as well as the
required memory and bus chips.

ASIC’s Solutions
} Industrial connector RJ45 IDC quick-connect
technology, no tools required Category 5e / 6A
} Industrial connector RJ45 Version V6; category 5e
IDC quick-connect technology
} Module holder, RJ45, female / IDC For TS35 DIN rail
Category 6
} RJ45 panel connector for front installation 22.5 mm
female/female 1:1 ,Category 5e/6
} Control cabinet bushing M12 - RJ45 female/female
1:1 Category 5e
} Cable gland, RJ45, female / IDC Version V6
Category 5e / 6, IDC, no tools required
} Cable gland RJ45 female / female Version V6
Category 5e
} Supports Profinet, SERCOS 3, EtherCAT,
Ethernet/IP, Powerlink ,Modbu-TCP many-more.

Process Automation Solutions


} T280, HART adapter with analog input.
} T210, Modbus RTU to HART converter.
} T810, The Wireless HART adapter with Modbus RTU
interface.
} T410 Modbus RTU to Profibus PA built-in converter.
} T600 built-in FF converter for HART instruments.
} T610_C FF built-in module for customized applications.
} T610_B Modbus® to FF built-in converter for actuators a n d
positioners.
} T610 Modbus to FOUNDATION fieldbus converter

www.ulepl.com 29
Fibre Optic
OPTO Link Armored Cable
} Single Mode / Multimode.
} 4, 6, 8, 12, and 24 core Cable.
} Industrial grade rugged construction.
} High Crush Resistance.
} Suitable for indoor / outdoor & direct burial installation.
} Available in OM1, OM2, OM3, OS1, OS2, 9/125, 50/125,
62.5/125.
} LSZH fiber optic cables
} Customization on request

ADSS Outdoor FO Cable


Applications
} All Dielectric Self Supporting cable (ADSS) for Outdoor use
} Particularly suitable for installation between poles with
a span of 100, 150, 420 meter.
} Initial sag at 20 ºC: 1% of span

Features & Benefits


} Available in sizes from 6 to 144 fibers
} Jelly filled (non-dripping and silicon-free) loose tubes with
primary coated optical fibres
} (Ø 250 ± 15 m)
} Full dielectric construction, no grounding required
} Aramid yarns for tensile strength
} Installation-friendly because of the cable core kept free of
grease (dry interstices)
} Length marking in meters for easy
} Inner Jacket Material – PE-Polyethylene
} Outer Jacket Material - PE – Polyethylene (Anti-Tracking)
} Available in OM1, OM2, OM3, OM4, 9/125, 50/125,
62.5/125, 125/250um.

Specifications
} Temperature Range (F1):
• Transport/Storage -30°C to +70°C
• Installation -5°C to +50°C
• Operation -30°C to +70°C
} Water tightness (F5): Pass
} RoHS, IEC-794-1, IEC-60794-1, EIA/TIA-455 Approved

www.ulepl.com 30
Fibre Optic
SFP Modules
} Provide speed 100Mbps,1Gbps and 10Gbps
} Available for single mode/multimode
} High operating temperature range
} Distance coverage from 2km to 120km
} Wavelength: 1310nm, 1510nm, 1550m, 1590nm
} Total industrial grade solution

LIU Box
} Fully Assembled LIU Box with Splice Trays, Pigtails
and Adaptors.
} Available in 4, 6, 8, 12, 16 ,20, 24, 36, 48 FO Ports
} Choice of SC/ST Adaptors & Pigtails.
} Housing available in MS, SS and Aluminum with
powder coating
} Din-rail, Wall mount and 19” Rack Mounting options
} Easy installation
} Customization on request

Patch Cords
} ST-ST – DUPLEX / SIMPLEX.
} SC-SC – DUPLEX / SIMPLEX
} ST-SC – DUPLEX / SIMPLEX.
} MTRJ-SC – DUPLEX / SIMPLEX
} MTRJ – ST – DUPLEX / SIMPLEX
} MTRJ – MTRJ – DUPLEX / SIMPLEX
} LC – SC – DUPLEX / SIMPLEX
} LC – ST – DUPLEX / SIMPLEX
} LC – LC – DUPLEX / SIMPLEX
} Available in MM, SM, OM1, OM2, OM3, OS1, OS2
of 1, 2, 3,5,10 meters.
} Customization on request

Pigtails/Adapter/Coupler
} Fiber Optic adaptors and Coupler available in
MM,SM,OM1,OM2,OM3,SC-SC,SC ST, Metal, Plastic,
Duplex, Simplex
} Excellent changeability and directivity
} 100% optic test (insertion loss)
} Accurate external size
} Fiber Optic pigtails available inM,SM,OM1,OM2,OM3,OS1,
OS2,SC,ST,LC Duplex, Simplex
} Polish type available in PC, UPC, APC Finish, Hybrid
} Cable Diameter 0.9 mm with 1m, 2m, 3m lengths.
} Standard or custom configurations
} Splice tray, Splice Holder and cable glands
www.ulepl.com 31
PROFIBUS
One Stop Solution for all your PROFIBUS needs!

Connector Cable Connector

PLC-1 PLC-2
Master Redundancy

Diagnostic Tool
Multi port Repeater/ Hub
for Star Topology

Fibre Optic Converter


Profibus RIO

Product Development Tool


Single Port Repeater

Cable Length max. 1.2 KM @ 9.6 kbps ASICs


RIO

IC module
Cable
Redundancy
DP-PA Coupler

PA Distributor Protocol Converter Modbus RTU Device

PA Devices M12
Connector Active Terminator

DP CABLE PA CABLE FO CABLE

Partnering with PROFIBUS is partnership with Leader!


Profibus International Competence Centre Indian Profibus & Profinet Association
India’s 1st & Only Profibus We are also authorized members for Profibus
International Competency International Organization in this region of Asia and
Centre (PICC) is set up by UL have played prominent role in forming Indian
Group. The engineers from all Profibus, Profinet Association (IPA). UL Group MD Mr
over the country look to PICC Lalit Sahani & Mr Dileep Miskin are office bearers of
for technology seminars, IPA. Today IPA has more than 100 companies as
training courses, Profibus active members and membership is ever-growing.
development support, network IPA is a platform where all the members get
validation reports and also the connected with Profibus International which is non-
consultancy for the new profit multinational company with presence in 20
network designs and installed countries. Other benefits members get are
networks. presentation & visibility in exhibitions, road shows
and seminars which are arranged throughout the
year.

www.ulepl.com 32
PROFIBUS
Online Monitoring & Networking
} ComBricks™ - The first PROFIBUS and PROFINET-based
automation system that unites network components,
permanent monitoring with ProfiTrace and remote I/O.
} Combricks Monitoring & Networking in Profibus DP/PA,
PROFINET, FF Protocol.
} No need of any Software .
} ProfiTrace OE - Remote monitoring in a web browser
} The only product with an integrated oscilloscope for
permanent PROFIBUS monitoring over Ethernet.

ComBricks Overview

Intelligent DP PA Coupler/ Link


} Seamless high speed integration to PROFIBUS PA Devices
} Adjusted bus parameters are not required and therefore
suitable for all DCS and PLC systems, even running on 12
Mbps.
} Allows you to remotely monitor your PROFIBUS
installations from anywhere in the world and will alert you
if any faults arise or are likely to arise.
} Jitter, noise, DC current, DC voltage, bar graph and
oscilloscope, it is all there and easy to access.

} The free CommDTM allows access for asset


management tools over Ethernet.
} The integrated PA termination
} It does not require configuration and operates the same
way as regular COMbricks repeaters.
} Can directly replace 3rd party Non-Ex PA couplers/links
and can be used as a monitor behind existing 3rd party
Non-Ex PA couplers.
} The only product with an integrated oscilloscope for
permanent PROFIBUS monitoring over Ethernet.
www.ulepl.com 33
PROFIBUS
Diagnostic Products
} Diagnostic Product are an essential tools for maintenance
and troubleshooting as it boosts the capabilities of service,
maintenance and engineering technicians.

} Application Areas:
• Troubleshooting and maintains of Profibus network,
Commissioning of Profibus network,
• Profibus product testing and verification,
• Passive cable testing,
• I/O testing of Profibus devices
• Education

PC / Laptop Based Mobile Analyzer


} This outstanding and portable currently the most powerful
mobile analyzer for PROFIBUS networks.
} Easy to use and unites all required elements in one to detect
several PROFIBUS faults.
} USB Powered Device & Galvanic isolated Profibus interface
} Live List: Colors make it easy
} Message Recording: The absolute truth
} Scope wave: The easiest oscilloscope ever
} Report: We have proof
} Bar Graph: The bar graph - is a useful Utility to get
impression of overall signal quality of the network.
} D P M a s t e r : C l a s s 1 & 2 m a s t e r, W i t h o u t P L C / D C S
Communicate Network
} Profibus PA Probe Ultra: PA Diagnostic

Handheld Diagnostic Tool


} Online functionality NetTEST II also detects sporadic
errors in running systems
} With the DP Master functionality NetTEST II becomes
an outstanding tool for the mobile commissioning of
DP Slaves
} PROFIBUS network can be lined up without using a
PLC
} Bar graph, Status Analysis, Different kind of line test
} Comprehensive Error Report, Generation Of Live List
} Signal level Measurement mobile commissioning.
Event triggering, Baud rate Scan, Level display
} Cycle time of the DP Network

www.ulepl.com 34
PROFIBUS
Profibus Tester - Handheld / PC Based
} Powerful diagnostic and troubleshooting tool
} Testing of cables, measuring the signals and analyzing the
communication of PROFIBUS networks.
} Battery powered, integrated graphical display.
} Provides direct display of measurement results in stand-alone
mode.
} Supports export of test results for advanced analysis.
} The cable test provides a detailed failure description and an
estimate distance between failure and test location.
} Allows full testing of live PROFIBUS segments with minimum
influence on their operation.
} The integrated master simulator allows bus testing.
} Single "suspicious" bus devices can be checked.

Profibus DP / PA Diagnosis via Ethernet


} DPMon & PAMon module gateway built with the isNet Lite can be
extended to operate as a PROFIBUS DP & PA diagnosis and
protocol monitor
} The module operates entirely passive & helps to detect and
investigate sporadic problems in the data transmission on a
PROFIBUS line, no telegrams will be sent to the PROFIBUS lines.
} Error counters or average time intervals, and for investigation of the
physical signal quality the integrated oscilloscope is quite useful.
} The PA Monitor module has two independently working
channels
} Physical signal quality the integrated oscilloscopes for every PA
channel are quite useful
} No PC is connected to the NetLite as captured telegrams are stored
on a SD card.

www.ulepl.com 35
PROFIBUS
Master Redundancy Switch
} PRS – Intelligent PROFIBUS DP Master Redundancy
Switch
} Top-hat rail based switch for the implementation of
redundant PROFIBUS DP Master systems.
} Allows the connection of two identical DP Masters to
the DP Slaves.
} Avoids galvanic contact between the DP Masters
} Masters be configured with identical PROFIBUS
addresses, making Multi Master mode unnecessary
and excludes double address conflict.
} In case of failure of the operational DP Master PRS
physically switches over to the stand-by DP Master
which seamlessly takes over the DP Slaves.

Cable Redundancy using


Multi-Port Repeater
} ProfiHub B2+R, B5+R, B5+RD, X5 Is an Advanced Flexible,
Robust network Component in Profibus as DP Repeater with
Redundant Profibus Channels
} If bus redundancy is enabled, 2 segments will form a
redundant pair
} Used in structure of Star/Tree Segment.
} B5+RD it is equipped with an additional integrated micro
ProfiTrace diagnostic unit. The ProfiHub offers a PROFIBUS DP
slave device to transfer bus statistics and device event
information to the PLC/DCS system.
} X5 on each segment has customizable baudrate selection
switch.
} Status LED’s, Alarm Contacts
} Diagnostic port for Monitoring on Each Channel
} Integrated channel termination
} Suitable for PROFIsafe and MPI apart from Profibus DP
} Configurable grounding system
} Redundant power supply
} Hot slave insertion/removal during operation
} Galvanically Isolated & Short circuit protection on each channel

www.ulepl.com 36
PROFIBUS
DP-DP Coupler
} Interlinks two PROFIBUS DP networks and permits
data transmission between the masters and the two
DP networks.
} Maximum size of the transmitted data: 244 Bytes I/P
and 244 Bytes O/P data.
} The DP/DP coupler is configured in the PLC/DCS
software by means of a GSD file.
} To get information of DP devices on Profibus.

PCI Cards
} Intelligent communication modules for PCs.
} Master or Slave functionality
} Handles all PROFIBUS protocol variants
} Interface with SCADA possible through OPC
support
} Models: DF PROFI II PCI, DF PROFI II Compact
PCI, DF PROFI II PC104+, DF PROFI II PCIe
} Communicate in Industrial PC
} Supported any diagnostic Tool

PCI Cards for Barmag Systems


} Desktop PCs as well as notebook devices without
PROFIBUS interfaces can be connected to PROFIBUS
stations within seconds based on the plug & play
features of USB.
} Operational areas are mobile set up and configuration
of field devices.
} The device is USB bus powered and it is not
dependent on external power connections.
} Its high transmission rate of up to 12 Mbit/s is of
special interest for fast application in the
manufacturing process like drive set-up and diagnosis.

www.ulepl.com 37
PROFIBUS
Multiport Repeater - IP20
} The signals are restored in level, slope, and duty cycle.
} All Baudarete Support Automatically
} Profibus & MPI Both are supported
} The status LEDs integrated for each segment provide
a quick overview of the current bus status
} Electrical isolation of all segments
} Star network with independent segments.
} Can be used for bus extension or as a spur line
} Increase the number of participants.
} DIP switch for switching off the individual segments
and a switch for turning off all segments.
} PROFIBUS connectors are required for connection to
the PROFIBUS cable.

Multiport Repeater - IP65


} The ProfiHub A5 is equipped with 5 galvanic isolated
transparent repeaters (offering 6 segments)
} To save costs on plugs and offer flexibility, it contains
screw terminals only.
} PROFIBUS DP installations and enables it in IP 65
applications
} Alarm Contact
} Redundant power supply.
} The status LEDs integrated for each segment provide
a quick overview of the current bus status
} With this product, you can create reliable, flexible and
object-oriented DP installations

Multiport Repeater with


FO Backbone
} The ProfiHub B2FO2+ & B4FO2+ is a cost-effective
solution to link PROFIBUS fiber optic to multiple
RS 485 segments and vice versa.
} Enables reliable applications where long cable
distances and an isolation between devices and
segments are required.
} The massed junction of copper segments reduce
expensive fiber optic couplers and create an object-
oriented overview for the end user.
} Fiber optic to multi RS 485 Segments coupler for
Point-to-point, bus- and star configurations
} 2 Fiber channels MM with 4 ST/BFOC connectors for
3 km cable length
} Multimode cable G62.5 / 125 (OM1) - 850 nm
} No limit in cascading
www.ulepl.com 38
PROFIBUS
Compact Repeater
} Isolated Channels (Repeater Segment)
} Used as bus extension or spur line
} Used in MPI networks
} Status LEDs per segment
} Repeater function can be deactivated
} Electrical isolation.
} No Power supply.
} Compact repeater to network
} Models : Compact, Twin

Single Port Repeater


} Increased RS 485 strength
} Isolated Channels (Repeater Segment)
} 31 devices per segment, 1.2 Km cable length (depends on
transmission speed)
} No limit in cascading
} Redundant DC power supply (19..28 VDC)
} Integrated termination facilities (switches).
} Configurable grounding system (direct or capacitive).
} Screw terminals and DB9 connectors.
} Hot slave insertion/removal during operation
} Galvanically Isolated & Short circuit protection on each channel
} Available in IP 20, IP 65

Active Terminator
} Bus termination independent of terminal device due
autonomous power supply
} Power supply independent of bus nodes
} Used as an active measuring point
} Diagnostic LEDs to indicate the status of the power supply
} Reliability & Flexibility provide Network.
} Active power terminator to Idle voltage
} Supply to active PROFIBUS components (Compact Repeater,
NETLink, PROFIBUS diagnostic connector)
} T1 comes with removable screw terminals and 1 DB9 connector
} Redundancy: Power 1 OR 2

www.ulepl.com 39
PROFIBUS
Connector - Metallic Body
} Available in 90, 0 , 35 Degree angled
} Metalized housing
} No loose parts
} Integrated programming / diagnostic port
} Integrated switchable terminating resistor
} Screw terminals
} With and Without LED Indication
} Easy Connect and Screw connect facility
} Optional DB9 with M12 Connectivity
} Support Rs 485 Technology

Connector - Metal Body


} Available in 90, 0 , 45 Degree angled
} Cable slots with transparent covers for high visibility
(wiring, position of screen and cable)
} Full metal construction for noise immunity and harsh
environment
} State monitoring via integrated LEDs for bus diagnosis
} Comfortable IDC technology for fast and reliable wire
connection.
} Captive singe-screw-mounting system - no loose parts
} Integrated switchable termination resistor
} Integrated programming / diagnostic port
} Support RS 485 technology.

Connector - M12
} Male, 4, 5, and 8-Pole .
} 5 poles, B coding, especially suitable for Profibus
signal cable
} Field attachable connector, M12 male connector 4, 5,
and 8-pole with threaded joint, shieldable, assembling
with screw terminals.
} Female, 4-, 5-, and 8-Pole
} Field attachable connector, M12 female connector
4, 5 and 8-pole with threaded joint, shieldable,
assembling with screw terminals.

www.ulepl.com 40
PROFIBUS
Network Design & Installation Support
} Operational bidding partners to all the leading OEM’s, System
Integrators and EPC Contractors.
} One stop solution for all Profibus needs such as Product, Service,
Diagnostic & Training.
} Qualified on-site engineers with vast field experience for field
analysis.
} Physically checked site data is sent to HO for expert analysis of
the network.
} Best available tools used for analysis and troubleshooting
purpose.
} Based on the observations modifications or corrections
suggested.
} Submission of the detailed audit service report to customer.
} Industries served such as Automotive, Steel, Cement, Packaging,
Pharmaceuticals, Chemical, Food & Beverages etc.

Diagnostic Services
} Profibus network troubleshooting
} Network audit services
} Network design & installation support
} 3rd Party audit service
} Annual maintenance contract (AMC’s)

Training Programme
} Profibus Basics, Maintenance & Troubleshooting
(2 DAYS)
} Certified Profibus Engineer (CPE)- DP (4 Days)
} Certified Profibus Engineer (CPA)- PA (2 Days)
} Profibus DP Development (2 DAYS)
} Certified Profibus Installer (2 Days)
} Profibus in House Training Program (3 days )

www.ulepl.com 41
PROFINET

Connector
} Quick-connect technology Easy Connect®.
} Visual connection control.
} Heavy-Duty metal housing.
} Transfer-rates of up to 100 Mbps
} Easy to mount and meet the IP20 requirements
} 4-wired Twisted-Pair cables
} Contact elements are highlighted according to the
colors of the wires to prevent wiring errors
} Models: 90 °/ 180°, RJ45, Easy Connect®, 10/100
Mbps

Connector - M12
} Field attachable connector, M12 male connector,
3 and 4-pole with threaded joint, shield able,
assembling with spring-type terminals.
} 0986 EMC 102: 4 poles, D coding, especially suitable
for Industrial Ethernet data cable.
} Connector with threaded joint.
} EMC shield able.
} Assembling with spring-type terminals.

PN/PN Coupler
} Connect two PROFINET networks.
} Enables data transmission between the controllers
of the two networks.
} Maximum size of the transmitted I/O data is
1,024 bytes.
} No additional configuration software is necessary.

DP/PN Coupler
} Connects your PROFIBUS to PROFINET.
} Simple and uncomplicated connection is possible.
} Maximum size of the transmitted data is 244
bytes of input.
} And 244 bytes of output data.
} Projected via GSD file and GSDML file.
} No additional configuration software is necessary.

www.ulepl.com 42
PROFINET
SWITCH 4, 8, 16 Port, Managed

} Prioritizing of the PROFINET frame traffic in the


machine network
} Integration into the automation network with GSDML
file.
} It is also possible to carry out a diagnosis and/or
configuration via Telnet or SSH.
} The supported PROFINET protocols, such as LLPD,
DCP, or even diagnosis alarms, can be easily configured
and administered.
} Neighborhood detection
} Ring redundancy
} Each port can be activated or deactivated
} Diagnostic messages for network problems
} Identification and maintenance data
} PROFINET Conformance Class B
} Connects upto 4,8, 16 participants of PROFINET
Network
} Port mirroring
} Time synchronization via SNTP

PCI Card
} The COMSOFT DF PROFINET IO board
operates as a PN IO Controller.
} Efficiency is so huge, the new board
achieves operations of 64 PROFINET
devices per millisecond in the
performance class RT.
} Excellent plant-wide networking, fast
data communication and long-term
availability are just a few of the many
benefits.
} Operate large networks without any
performance restriction.

www.ulepl.com 43
PROFINET
Diagnostic Tool
} Compact and efficient tool.
} It generates a live list of the PROFINET/Ethernet
network.
} A detailed report provides information about the
reliability of the PROFINET network.
} Netilities utilizes the standard Ethernet/WLAN port on
the PC or interfaces with a ProfiTap.
} Netilities is also used to set Device Names and IP
addresses and export the detected devices to CSV.
} The LED test feature can visualize the targeted
PROFINET device.
} Real Time scan / Live List of the complete network.
} Suitable for other Ethernet systems.

Monitoring Tool
} Usable for most PROFINET/Ethernet monitoring tools.
} No loss of messages.
} Time stamped messages.
} Does not endanger the real-time behavior.
} No security hazards Is not visible for switches/devices.
} Grounding concept is not disturbed.

Handheld Cable Tester


} Essential tool to verify the condition of the PROFINET
cable after assembly and installation.
} With just 1 key-press the test result is directly displayed
and continuously updated.
} Utilized on all other Ethernet networks with 4-wire and
8-wire shielded cables.
} This outstanding tool that fits in your pocket.
} Boost the efficiency of installers and maintenance
technicians.

Training Programme
} Certified PROFINET Engineer (CPNE) (4 Days)
} PROFINET Technical Training (1 Days)

www.ulepl.com 44
CANBUS
PN/CAN Gateway
} PN/CAN gateway is a PROFINET I/O device and supports
transfer rates up to 100 Mbps full duplex; and up to 1 Mbps
on the CAN bus
} The PN/CAN gateway is integrated with a GSDML file in the
hardware configurator
} No other software tools for configuration
} handling blocks for programming are necessary, making
gateway use straightforward.
} Supports the CANopen master protocol
} Up to 127 CANopen slaves possible.
} SDO communication, emergency messages, participant
monitoring with heartbeat and node guarding
} Up to 16 PDOs can be configured for each CANopen®
slave
DP/CAN Coupler
} The I/O data of the CAN open® participants is shown in
the PROFIBUS in a transparent and freely configurable
manner.
} The DP/CAN coupler is integrated in the hardware
configurator with a GSD file
} PB Coupler12 Mbps & CAN up to1Mbps
} The PROFIBUS address is set using a DIP switch.
} 3 status LEDs
} USB port for firmware updates
} Up to 15 CAN open participants
} CANopen master and CAN Layer 2 possible

CAN Bridge
} CAN networks have different transfer rates or work
with different protocols,
} A flexibly adjustable filtering logic can accept freely
selectable identifiers and transfer them to the other
network.
} Connect different CAN networks (different
transmission rates / different protocols)
} Automatic detection of transmission rates
} 5 LEDs indicate the status of the device and the
connected CAN networks.
} The CAN bridge allows a flexible design of the network
topology; star and tree structures as well as extensive
line structures can be implemented.

Connector
} Available in 90 & 0 Degree angled
} With & Without PG Port
} Metalized housing
} No loose parts
} The switch can also be operated in the installed condition.
} The setting is clearly visible.
} additional connection jack
} Integrated switchable terminating resistor
} Screw terminals
} With and Without LED Indication
} Easy Connect and Screw connect facility
} Optional DB9 with M12 Connectivity
} Support Rs 485 Technology
www.ulepl.com 45
Distributed
Field bus I/O System
TB 20 Distributed Field bus I/O system is
used for I/Os in the field to receive data from
field & collectively gives to their respective
bus system for data transmission. It’s
electrically isolated from backplane bus &
also wire break detection alarm.
USB device port for online diagnostics,
configuring parameters, setup, and firmware
updates with "TB20 ToolBox"
TB20 ToolBox simulation for setting up the
I/O system without a higher-level controller in
order to test the system`s operation (I/O
check)
With the TB20 I/O system you generate
efficient and functional added value for a
variety of application areas – irrespective of
the field bus and proven in practice!

Three-component Ideal handling, Clear, unique labels Hot-Swap capability


module design achieved with a compact design

TB 20 TOOL BOX
Makes it easy to methodically design TB20 systems.
From selecting and positioning components and
configuring their parameters to printing label strips
and documentation for projects
} SMART PLANNING AND CONFIGURATION
} Real Time Diagnosis
} Importing & Exporting Symbols
} Simulation

www.ulepl.com 46
Component For S7
CANopen Solutions for Siemens
CM CANopen 1 SI CANopen

} The CM CANopen enables system integrators to connect } The 1 SI CANopen module brings CANopen connectivity to
any CANopen or CAN 2.0A device to the SIMATIC S7-1200 the SIMATIC ET200S modular I/O system, enabling full
PLC. The module plugs into the communication module integration between devices on a CANopen network and
interface of the S7-1200 and acts as a bridge between the the ET200S. Furthermore, the addition of 1 SI CANopen
CANopen or CAN devices and the SIMATIC basic module into the ET200S system allows a CANopen network
controller, allowing integrators to choose from a wider to be seamlessly controlled from PROFIBUS and PROFINET.
range of automation products when designing their } The 1 SI CANopen module is supported by all interface and
system. CPU modules of the SIMATIC ET200S modular I/O system,
} Transparent CAN 2.0A functionality with the CM CANopen with the exception of the Basic and Compact versions.
} CAN 2.0A supported } Transparent CAN 2.0A functionality with the 1 SI CANopen
} Approved. } Functionality supported in transparent CAN mode
} Approved.

www.ulepl.com 47
Component For S7

Communication Module
for CANbus
} Supports CAN 2.0A (11 bit) and CAN 2.0B (29 bit)
frames with a freely selectable transfer rate from
10 kbps to 1 Mbps.
} CAN Module Send telegram CAN Master & CAN
Slave
} There are 16 freely settable timers available in the
CAN 300 PRO
} DIP switch for setting the transfer rate and station
address facilitates commissioning
} Eplacement of the parameterization or the module
during servicing can be carried out quickly.
} 6 LEDs indicate the operating status of the module.
There is a USB interface for diagnostics and
parameterization.
} Extensive CAN bus diagnostics possibilities
} Extended ambient temperature
} The module can be plugged into either the central
frame or the expansion frame
} CAN Module Send telegram CAN Master & CAN
Slave
} It supports CAN 2.0A (11 bit) and CAN 2.0B (29 bit)
frames with a freely selectable transfer rate from
10 kbps to 1 Mbps.
} The CAN 400-1 can be operated as Layer 2,
CANopen® master or CANopen® slave.
} DIP switches for address + transfer rate
} USB interface for parameterization and diagnostics
} 1 CAN interface & CAN 2 Interface
Communication Module for
Serial Interface
} The SAS range of serial communication module for
use in S7-300* systems.
} It allows the connection to the PLC of serial devices
such as barcode scanners, operator terminals, serial
printers, PCs, PLCs of other manufacturers and
supports the protocols ASCII and 3964R.
} The features advanced functions such as support for
higher baud rates up to 115 kBaud, making it flexible
without any loss of compatibility.
} The handling blocks supplied enable simple and
flexible integration into the PLC.
} The module is parameterized in the hardware
configurator of the PLC.
} The expanded functionalities can also easily be
activated with the handling blocks.
} A virtual COM port driver enables the use of software
that expects a COM interface
} The SAS 340-1 & 341-1 has 1 x RS422/RS485
} The SAS 340-2 & 341-2 has 2 variant 2 x RS232, 2 x
USB & 2 x RS422/RS485
www.ulepl.com 48
Component For S7

Configuration Tools
} Programming, configuring and visualizing
S7 PLCs
} Flexibility, compact design and even more
application benefits.
} Power is supplied via the CPU of the
automation unit or optionally by an external
24 V DC power unit.
} MPI/PPI/PROFIBUS to Ethernet TCP/IP via
USB, Wireless, Ethernet Switch media.
} Ethernet to Profinet Gateways.

Memory Cards /
Micro Memory Cards
} The memory card with a capacity of
4,12,24,256, MByte & 2GByte is suitable for
use in the S7-1200*/S7 1500*
} The micro memory card with a capacity of
64,128,256,512 kByte & 1,2,4,8 MByte is
suitable for use in the S7-300* and ET200S
} The Flash EPROM Card with a capacity von
256 kByte is designed for use in CPU modules
from CPU 412 to CPU 417.
} The RAM Card with a capacity von 64,256
kByte & 1MByte is designed for use in CPU
modules from CPU 412 to CPU 417 400 Series

Input / Output Modules


} Component S7 IO module from UL–Helmholz range is
Compatible modules for equivalent to ET-200 system.
} One to One equivalent Card.
} No any configuration.
} Available in Front Connector Screw ,Easy. PIN 20,40 .
} ALL Siemens S7 series spare available in Helmholz
Make AI AO DI DO PT 100.
} S7 I/O Module, Din Rail, Memory Card

Front Connector & Accessories


} Front Connector with cable, spring-type terminal &
easy connect facility
} Front Connector without cable, spring-type terminal &
easy connect facility
} Front adaptor for S7 modules, FastPlug
} Available in 20, 40 pin
} Mounting Rails

www.ulepl.com 49
Component For S7
Interface Converter - MPI Bus
MPI (Multi-Point Interface) is the integrated interface
for SIMATIC products such as controllers, panels,
programming devices, PCs, etc. Transmission media
of MPI includes electrical standard RS485, optical
medium, etc. which are also used by PROFIBUS.

FEATURES:
} Programming and Visualization
} Transfer rate upto 115kbps
} Power Supply from the AD or external 24V
} Parameterization and diagnostic functions are
possible using the SHTools software.

S5 Interface Converter
} A special virtual COM driver enables the use of common
programming tools, such as STEP* 5 V7.2 from
Siemens.
} The power is supplied via the CPU or externally (24 V).
} Virtual COM port for all common commissioning tools
} Fits onto any standard S5-CPU
} Unique detection on the network through device names
} Program S5 via TCP/IP

SSW3 Interface Converter


} The RS232/TTY converter is completely integrated into
the 15-pin connector
} Housing, an external power supply is therefore not
required.
} The transmission of data signals takes place over an
RS232 connection.
} Every programming software on a PC
} Online coupling with the AD with data exchange
} Visualization and coupling software
} The cable is 5 m long. 10 & 15 mtr Long.

www.ulepl.com 50
Product Range
Product Group Range

SMPS: Single/ Three Phase; 0.75 A- 100 A; As per CE/UL/CSA/TUV approved


Signal Isolators b Converters: Current/ Voltage/ Frequency/ Temperature. Two & Three Way Isolation.
Programmable Converters
Industrial Interface Relays: Electromechanical/ Solid State/ Miniature. Basel PCB Mounted; 2/3/4 Change Over.
Coil Voltages up to 220 V DC
Forcibly Guided Contacts Relays
Barriers & Isolators: Intrinsically Safe Area Barriers & Isolators; HART Management Software & Hardware

Active I/O Module: Standalone IP67 /IP 68/IP69K modules and bus connectors/cables for field wiring
I/O Systems -LioN-Link: the new modular IP67 distribution system for decentralized utility.
Passive Distributors: Actuator/Sensor distribution boxes - for effective bundling of parallel wiring, with M8 or
M12 sockets.
Sensor- Actuator
Solutions Sensor Cables: Cord sets, Double-ended, Single Ended Sensor Cable
M12 M8 M23 7/8" Circular Connectors/and Adapters: Connectors and Cord sets for Actuators, Sensors and
Data & T-Connectors (Splitters) and Adaptors.
Valve Connectors, Form A, B, C (GDM-Series): Rectangular connectors for hydraulic, pneumatic and electro-
magnetic actuators

Control: Unshielded 6 Shielded; Stationary / Drag Chain; PVC/TPE/HFF R/PUR/FRLS. As per


VDE/CE/UL/CSA/ HAR standards
Power: Copper / Aluminum; Un-armoured/ Armoured; XLPE/ PVC/ HFFR/ FRLS. As per VDE/CE/UL/CSA/ IEC
Data & Signal: Unshielded 6 Shielded; Cored/ Paired; Stationary / Drag Chain; PVC/TPE/HFFR/PUR/FRLS/ PE.
As per VDE/CE/UL/CSA
Instrumentation: Un-armoured/ Armoured; Unshielded/ Shielded; Paired/ Triad; XLPE/ PVC/ HFFR/ FRLS.
As per BS 5308
Servo: Unshielded 6 Shielded; Stationary / Drag Chain; PVC/TPE/HFFR/PUR.
Suitable for SIEMENS; INDRAMAT;LENZE etc. As per VDE/CE/UL/CSA/ DESINA standards
VFD: Shielded; XLPE/PE/PVC/TPE/HFFR As per VDE/CE/UL/CSA
Encoder: Shielded; Stationary / Drag Chain; PVC/TPE/HFF R/PUR. Suitable for SIEMENS; HEIDENHAIN;
NUM; B6R; FANUC; INDRAMAT; BERGER LAHAR etc. As per VDE/CE/UL/CSA/ DESINA Std.
Cables Robotics: Unshielded b Shielded; Cored/ Paired; TPE/PUR/ POLYOLEFINES. As per VDE/CE/UL/CSA
Field Bus: Profibus; Profinet; Modbus; DeviceNet; Ethernet; CANOpen; CC-Link; EIB/KNX; Foundation Field
Bus etc
High Temperature: SILICON/FEP/PTFE/ ETFE/ SPL. POLYMER COMPOUND. 105 -1400 Deg.C.
As per VDE/CE/UL/CSA
Material Handling: Control/ Power; Un-shielded/Shielded; Round/ Flat; PVC/TPE/PUR/ EPR/ NEOPRENE/
SPL. RUNBBER COMPOUND. For Festooning/ Drum Reeling. As per VDE/CE/ HAR standards
Single Cores: PVC/XLPE/PUR/HR-PVC/FRLS/HFFR. As per IS 694/IEC/VDE/UL/CSA/HAR/BS standards Fire
Alarm / Survival/ Resistance: As per IEC 60331/ BS 5839-I
Welding: PVC / FPR. As per HAR/ IS standards
Co-axial: RG 6/11/58/59/62/71/174/178/179/187/188/213/214/ 216/223/316
Customized: Spiral; Cable Assemblies far SERVO; FEEDBACK; RESOLVER

Glands: Polyamide/ Metal; PG/Metric/NPT. As per VDE/UL/CSA


Conduits: PoIyamide/PVC/PE/POLYPROPELYNE. As per VDE/CE/UL/CSA standards EMC Clamps & Heat
Cable Accessories Shrinking Sleeves
Lugs: Insulated; Non-Insulated; Twin / Round; Fork; PIN: Insulated & Non Insulated / Tabs & Receptacles:
Insulated b Non Insulated

Thermal Management Thermostats; Hygrostats; Heaters; Fan Heaters; Fan Filter Unit; Drain Valves; Pressure Compensating
devices.

Tools Cutting; Stripping & Crimping Tools

Panel Wiring Solution LSC Wiring Solution

Control panel punching tools


Sheet Metal & Bus Bar Cu/Al busbar punching/ Bending & Cutting Tools & Machines
Processing Tools &
DIN rail, wire duct and busbar cutting.
Machines
Metal core drilling machines and accessories.
Thick metal sheet punching tools.
Metal edge deburring and beveling tools.
Magnetic Weight Lifters
www.ulepl.com

Regional Sales Offices :

Delhi / NCR:
[email protected]
Mob.: +91-9350954880
[email protected]
Mob.: +91-7391002020
[email protected]
Mob: +91-9729268629
Mumbai:
[email protected]
b.: +91-9769814605
[email protected]
Chennai:
[email protected]
[email protected]
Bangalore:
[email protected]
Mob.: +91-7028011776
Hyderabad:
[email protected]
Mob.: +91-9890767899
Coimbatore:
[email protected]
Mob.: +91-9344106088
Kolkata:
[email protected]
www.shubhamad.com~2k18

UL Electrodevices Pvt. Ltd. Authorised Chanel Partner

Nirman Classic, Katraj-Kondhwa Road,


Katraj, Pune - 411046. INDIA.
Ph.: +91 20 26960040/50/60 Fax: +91 20 26962079
E mail: [email protected] Website: www.ulepl.com

You might also like