MasterRoc-HCA-10 Technical Data Sheet
MasterRoc-HCA-10 Technical Data Sheet
Cement hydration control system for wet and dry sprayed concrete, grouting and cement
injection
Page 1 of 2
MasterRoc HCA 10
CONSUMPTION The maximum storage temperature for MasterRoc
HCA 10 is +60°C. Performance tests should always
be carried out prior to use.
If stored in tightly closed original containers and
under the above mentioned conditions, it has a shelf
life of at least 12 months.
Dosage indicated in this data sheet is only to be MasterRoc HCA 10 is an irritant fluid. Contact with
used as a guideline. To obtain accurate dosage skin and eyes must be avoided. It is essential that
rates, field tests, have to be done with cement and safety glasses and rubber gloves are worn during
aggregates under local conditions. It is handling. In case of contact with eyes or skin, flush
recommended that you consult your local immediately with plenty of water and seek medical
representative. advice.
Normal recommended dosage of MasterRoc HCA For further information, see the Material Safety Data
10 varies between 0.2% - 1% by weight of cement. Sheet.
The required dosage depends on: type of cement
used, w/c ratio, ambient and concrete temperature
and targeted open time.
STORAGE
Minimum storage temperature for MasterRoc HCA
10 is +1°C. If it has frozen, thaw and completely
reconstitute with a mild mechanical agitation. Do not
use pressurized air for agitation. Please contact your
local representative prior to the use of any products
that have frozen.
® = registered trademark of a MBCC Group member in many countries of the world SG#MasterRoc HCA 10 v1. 07.2021
The technical information and application advice given in this Master Builders Solutions publication are based on the
STATEMENT OF present state of our best scientific and practical knowledge. As the information herein is of a general nature, no
RESPONSIBILITY assumption can be made as to a product's suitability for a particular use or application and no warranty as to its
accuracy, reliability, or completeness either expressed or implied is given other than those required by law. The user
is responsible for checking the suitability of products for their intended use.
Field service where provided does not constitute supervisory responsibility. Suggestions made by Master Builders
NOTE Solutions either orally or in writing may be followed, modified, or rejected by the owner, engineer or contractor since
they, and not Master Builders Solutions, are responsible for carrying out procedures appropriate to a specific
application.
www.master-builders-solutions.com/en-asiapacific