GWP Expected Sewage Flows
GWP Expected Sewage Flows
RANGE RECOMMENDED
TYPE OF ESTABLISHMENT UNIT GALLS/UNIT/DAY FOR DESIGN
Churches
with or without kitchen per seat 2-5 3
Commercial/Industry
Airports, Bus or Rail Depot per passenger 5 5
(not including food facilities)
1
RANGE RECOMMENDED
TYPE OF ESTABLISHMENT UNIT GALLS/UNIT/DAY FOR DESIGN
Dwelling Units
Boarding House per person 50-75 75
per bedroom 120-150 150
with meals per person 75-100 100
Institutions
Home for the Aged per bed 50-125 125
Recreational
Camps
Day (no meal served) per person 10-20 15
2
RANGE RECOMMENDED
TYPE OF ESTABLISHMENT UNIT GALLS/UNIT/DAY FOR DESIGN
Recreational (cont'd)
Parks
with toilet only per person 5-10 7
with bathhouse, toilet and kitchen per person 10-25 20
Schools
Day
With cafeteria, gym, showers per person 20-30 30
without cafeteria, gym and showers per person 10-17 15
with cafeteria only per person 12-21 21
11/30/09