M400 2-wire Transmitter Series

for pH, Oxygen, and Conductivity


Versatile, intelligent transmitters for harsh conditions, with HART® interface

Technical Data

Short description
The M400 2-wire transmitter series is the state-of-the-art transmitter for most demanding conditions in
hazardous area applications. The transmitter series features advanced ISM technology and covers pH / ORP,
amperometric Oxygen, and Conductivity measurements. Thanks to the mixed-mode input functionality, the
M400 accepts any analog or ISM sensor of your choice. The M400 is a single-channel, multi-parameter unit.
The same unit can handle different parameters such as pH / ORP, amperometric Oxygen (for measurement of
dissolved oxygen or in gas) or Conductivity, depending on the type you choose.

Features
– ATEX / FM* approved for X version
– Advanced ISM functionalities
– Mixed-mode input (analog or ISM sensors accepted)
– HART® communication as a standard
– Multi-parameter unit
– Dynamic Lifetime Indication
PENDING
– Adaptive Calibration Timer
– Time to Maintenance Indication
– Two 4 … 20 mA current outputs, galvanically isolated, as a standard
– 2 freely configurable digital output signals, 2 digital input signals
– IP 66 / NEMA 4X rated
– PID controller with pulse length or pulse frequency
– Quick setup mode
– 8 languages: english, german, french, italian, spanish, portuguese, russian and japanese
* pending

Contents Dimensions and installation drawings 2

Specifications 3

Connector terminal definitions 6

Ordering information 7
Dimensions and installation drawings M400 2-wire transmitter series

Assembly

1 3 M20 ⫻ 1.5 cable glands


2 2 plastic plugs
3 4 screws

Dimension drawings

114 mm / 4.49"
150 mm /5.9" 27 mm
1.06"
136 mm / 5.35"
150 mm / 5.9"
6.5 mm

43 mm 28 mm
0.256"

1.69" 1.10"
90 mm
3.54"

90 mm /3.54"
0,0 mm
0,5 mm

0.02"
90 mm/ 3.54"

0.0"
+

+


137 mm
5.39"

+ 0,5 mm
137 mm – 0,0 mm
5.39" + 0.02"
– 0.0"

2
Specifications M400 2-wire transmitter series

pH / ORP

Measurement parameters pH, mV, and temperature


pH, ORP input range –1500 to 1500 mV
pH display range –2 to 16 pH
Resolution Auto / 0.001 / 0.01 / 0.1 / 1 (can be selected)
Relative accuracy * ± 0.02 pH; ± 1 mV
Temperature input Pt 1000, Pt 100
Temperature compensation Automatic / manual
Temperature measuring range –30 to 130 °C (–22 to 266 °F)
Temperature resolution Auto / 0.001 / 0.01 / 0.1 / 1 °C /°F (can be selected)
Temperat. measurement error* ± 0.25 K in the range of –10 to + 80 °C (14 to +176 °F)
Max. length sensor cable Analog: 20 m (65 ft), depending on sensor; ISM 80 m (260 ft)
Calibration 1 or 2 point calibration, process calibration
* For analog input signal (ISM input signal causes no additional error)

Oxygen amperometric

Measurement parameters
– Dissolved oxygen Saturation or concentration and temperature
– Oxygen in gas Concentration and temperature
Current range 0 to 7000 nA for analog sensors
Oxygen measuring ranges
– Dissolved oxygen Saturation: 0 to 500 % air, 0 to 100 % O2
Concentration: 0.00 ppb (µg/L) to 50.00 ppm (mg/L)
– In gas 0 to 9999 ppm O2 gas, 0 to 100 vol % O2
Oxygen accuracy*
– Dissolved oxygen Saturation: ±0.5% of the measured value or ±0.5%, depending on
which is larger.
Concentration at high values: ±0.5% of the measured value or
±0.050 ppm / ±0.050 mg/L, depending on which is larger.
Concentration at low values: ±0.5% of the measured value or
±0.001 ppm / ±0.001 mg/L, depending on which is larger.
Concentration at traces values: ±0.5% of the measured value or
±0.100 ppb/±0.1 µg/L, depending on which is larger.
– In gas ±0.5% of the measured value or ±5 ppb, depending on which is larger
for ppm O2 gas.
±0.5% of the measured value or ±0.01%, depending on which is larger
for vol % O2.
Resolution current 6 pA
Polarization voltage – 1000 to 0 mV for analog sensors
– 550 mV or – 674 for ISM sensors (configurable)
Temperature input NTC 22 kΩ, Pt 1000
Temperature compensation Automatic
Temperature measuring range –10 to 80 °C (14 to 176 °F)
Temperature accuracy* ± 0.25 K in the range of – 10 to + 80 °C (14 to + 176°F)
Max. length sensor cable Analog: 20 m (65 ft); ISM 80 m (260ft)
Calibration 1-point (slope or offset) calibration, process calibration (slope or offset)
calibration
* For analog input signal (ISM input signal causes no additional error)

3
Specifications M400 2-wire transmitter series

Conductivity 2-e / 4-e

Measurement parameters Conductivity, and temperature


Conductivity ranges 2-electrode sensor: 0.02 to 2000 µS /cm (500 Ω ⫻cm to 50 MΩ ⫻cm)
C = 0.01 0.002 to 200 µS/cm
C = 0.1 0.02 to 2000 µS/cm
C= 1 15 to 4000 µS/cm
C= 3 15 to 12000 µS/cm
C = 10 50 to 40000 µS/cm
4-electrode sensor: 0.01 to 650 mS/cm (1.54 Ω⫻cm to 0.1 MΩ⫻cm)
Temperature input Pt 1000
Temperature measuring range – 40 to 200 °C (– 40 to 392 °F)
Max. length sensor cable 60 m (196.9 ft) with 2-electrode sensor
15 m (50 ft) with 4-electrode sensor
80 m (260 ft) with ISM sensor
Cond / Res accuracy * ± 0.5 % of reading or 0.25 Ω, whichever is greater, up to 18 MΩ ⫻cm
Cond / Res repeatability * ± 0.25 % of reading or 0.25 Ω, whichever is greater
Cond / Res resolution Auto / 0.001 / 0.01 / 0.1 / 1 (can be selected)
Temperature resolution Auto / 0.001 / 0.01 / 0.1 / 1 °C /°F (can be selected)
Temperature accuracy * ± 0.25 °C (± 0.45 °F) in the range of –30 to +150 °C (–22 to +302 °F)
±0.5°C (±0.45°F) outside the range of –30 to +150°C (–22 to +302°F)
Temperature repeatability * ± 0.13 °C (± 0.23 °F)
Chemical concentration NaCl 0 – 26 % @ 0 °C to 0 – 28 % @ + 100 °C
curves NaOH 0 – 12 % @ 0 °C to 0 – 16 % @ + 40 °C to 0 – 6 % @ + 100 °C
HCl 0 – 18 % @ – 20 °C to 0 – 18 % @ 0 °C to 0 – 5 % @ + 50 °C
HNO3 0 – 30 % @ – 20 °C to 0 – 30 % @ 0 °C to 0 – 8 % @ + 50 °C
H2SO4 0 – 26 % @ – 12 °C to 0 – 26 % @ + 5 °C to 0 – 9 % @ + 100 °C
H3PO4 0 – 35 % @ + 5 °C to +80 °C
User-defined concentration table (5 ⫻ 5 matrix)
TDS ranges NaCl, CaCO3
Calibration 1 or 2 point calibration, process calibration
* For analog input signal (ISM input signal causes no additional error)

Electrical specifications

Number of outputs (analog) 2


Current outputs Loop current 4 to 20 mA, galvanically isolated up to 60 V from input
and from earth / ground, protected against wrong polarity, feeding volt-
age 14 to 30 V DC
Measurement error through < ± 0.05 mA over 1 to 20 mA range
analog outputs
Analog output configuration Linear, Bi-linear, Logarithmic, Autoranging
Display Backlit LCD, 4 lines
Running capacity Ca. 4 days
Keypad 5 tactile feedback keys
Languages 8 (english, german, french, italian, spanish, portuguese,
russian and japanese)
PID process controller Pulse length, pulse frequency

4
Specifications M400 2-wire transmitter series

Electrical specifications (cont.)

Cycle time Ca. 1 sec.


Hold input / Alarm contact Yes / Yes (alarm delay 0 to 999 s)
Connection terminals Spring cage terminals, appropriate for wire cross section
0.2 mm2 to 1.5 mm2 (AWG 16 – 24)
Digital outputs 2 open collector (OC), 30 V DC, 100 mA, 0.9 W
Digital input 2, galvanically isolated up to 60 V from output, analog input and
ground / earth with switching limits
0.00 V DC to 1.00 V DC inactive
2.30 V DC to 30.00 V DC active
Analog input 4 to 20 mA (for pressure compensation)
Alarm relay delay 0 – 999 s

Environmental specifications

Storage temperature – 40 to 70 °C (– 40 to 158 °F)


Ambient temperature operating range – 20 to 60 °C (– 4 to 140 °F)
Relative humidity 0 to 95%
EMC According to EN 61326-1 (general requirements)
Emission: Class B, Immunity: Class A
Certificate CE
Material Aluminium die cast
Hazardous areas M400/2H: cFMus Class I Division 2*, NEPSI Ex Zone 2
M400/2XH, M400G/2XH: ATEX/IECEx Zone 1, cFMus Class I Division1*,
NEPSI Ex Zone 1
* pending

Mechanical specifications

Dimensions Housing (H ⫻W ⫻D) * 144 ⫻144 ⫻116 mm


Front bezel (H ⫻W) * 150 ⫻150 mm
Max. D – panel mounted 87 mm
Weight 1.50 kg (3.3 lb)
Insulation / Rating IP 66 / NEMA 4X
* H = Height, W = Width, D = Depth

5
Connector terminal definitions M400 2-wire transmitter series

Connector terminal definitions

TB1

Terminal
1 DI1+
2 DI1–
3 DI2+
4 DI2–
5 not used
6 OC1+
2 7 OC1–
8 OC2+
1 9 OC2–
10 AO1+ / HART
11 AO1– / HART
12 AO2+
 TB1 – Input and output analog signal 13 AO2–
 TB2 – Sensor signal 14 not used
15 

TB2 terminal definitions


Analog sensor

M400 M400 M400


pH transmitter Oxygen transmitter Conductivity (2-e/4-e) transmitter
Terminal Terminal Terminal
A Glass A not used A Cnd inner1
B not used B Anode B Cnd outer1
C not used C Anode C Cnd outer1
D not used D Reference D not used
E Reference E not used E Cnd outer2
F Reference F not used F Cnd inner2
G Solution GND G Guard G Cnd outer2 (GND)
H not used H Cathode H not used
I RTD ret (GND) I NTC ret (GND) I RTD ret (GND)
J RTD sense J not used J RTD sense
K RTD K NTC K RTD
L not used L not used L not used
M Shield (GND) M Shield (GND) M not used
N not used N not used N not used
O not used O not used O not used
P not used P + input of 4 / 20 mA signal P not used
Q not used Q – input of 4 / 20 mA signal Q not used

6
Connector terminal definitions & Ordering information M400 2-wire transmitter series

Connector terminal definitions (cont.)

TB2 terminal definitions

ISM sensor
Terminal
A not used
B not used
C not used
D not used
E not used
F not used
G not used
H not used
I not used
J not used
K not used
L Cable core
M Shield (GND)
N not used
O not used
P not used
Q not used

Ordering information

Transmitter Order no.


M400/2H, 1-channel multi-parameter 30 025 514
M400/2XH, 1-channel multi-parameter 30 025 515
M400G/2XH, 1-channel multi-parameter 30 025 516

Parameter guide M400/2(X)H, M400G/2XH


Parameter M400/2(X)H M400G/2XH
Analog ISM Analog ISM
pH / ORP • • • •
Conductivity 2-e • – • –
Conductivity 4-e • • • •
Amp. DO ppm / ppb / trace •* / • / • •* / • / • •* / • / • •* / • / •
Amp. O2 gas ppm / ppb / trace – – •/–/– •/•/•
* Ingold and Thornton sensors

Accessories Order no.


Pipe mount kit 52 500 212
Panel mount kit 52 500 213
Protective hood 52 500 214

7
METTLER TOLEDO Market Organizations

Sales and Service:

Australia France Malaysia Slovenia


Mettler-Toledo Ltd. Mettler-Toledo Mettler-Toledo (M) Sdn Bhd Mettler-Toledo d.o.o.
220 Turner Street Analyse Industrielle S.A.S. Bangunan Electroscon Holding, U 1-01 Pot heroja Trtnika 26
Port Melbourne 30, Boulevard de Douaumont Lot 8 Jalan Astaka U8 / 84 SI -1261 Ljubljana-Dobrunje
AUS - 3207 Melbourne / VIC F - 75017 Paris Seksyen U8, Bukit Jelutong Phone +386 1 530 80 50
Phone +61 1300 659 761 Phone +33 1 47 37 06 00 MY - 40150 Shah Alam Selangor Fax +386 1 562 17 89
Fax +61 3 9645 3935 Fax +33 1 47 37 46 26 Phone +60 3 78 44 58 88 e-mail [email protected]
e-mail [email protected] e-mail [email protected] Fax +60 3 78 45 87 73
e-mail South Korea
Austria Germany [email protected] Mettler-Toledo (Korea) Ltd.
Mettler-Toledo Ges.m.b.H. Mettler-Toledo GmbH Yeil Building 1 & 2 F
Südrandstraße 17 Prozeßanalytik Mexico 124-5, YangJe-Dong
A -1230 Wien Ockerweg 3 Mettler-Toledo S.A. de C.V. SeCho-Ku
Phone +43 1 604 19 80 D - 35396 Gießen Ejercito Nacional #340 KR -137-130 Seoul
Fax +43 1 604 28 80 Phone +49 641 507 333 Col. Chapultepec Morales Phone +82 2 3498 3500
e-mail [email protected] Fax +49 641 507 397 Del. Miguel Hidalgo Fax +82 2 3498 3555
e-mail [email protected] MX - 11570 México D.F. e-mail [email protected]
Brazil Tel. +52 55 1946 0900
Mettler-Toledo Ind. e Com. Ltda. Great Britain e-mail [email protected] Spain
Alameda Araguaia, 451 Mettler-Toledo LTD Mettler-Toledo S.A.E.
Alphaville 64 Boston Road, Beaumont Leys Poland C / Miguel Hernández, 69-71
BR - 06455-000 Barueri / SP GB - Leicester LE4 1AW Mettler-Toledo (Poland) Sp.z.o.o. ES - 08908 L’Hospitalet de Llobregat
Phone +55 11 4166 7444 Phone +44 116 235 7070 ul. Poleczki 21 (Barcelona)
Fax +55 11 4166 7401 Fax +44 116 236 5500 PL - 02-822 Warszawa Phone +34 902 32 00 23
e-mail [email protected] e-mail [email protected] Phone +48 22 545 06 80 Fax +34 902 32 00 24
[email protected] Fax +48 22 545 06 88 e-mail [email protected]
Hungary e-mail [email protected]
China Mettler-Toledo Kereskedelmi KFT Sweden
Mettler-Toledo Instruments Teve u. 41 Russia Mettler-Toledo AB
(Shanghai) Co. Ltd. HU -1139 Budapest Mettler-Toledo Vostok ZAO Virkesvägen 10
589 Gui Ping Road Phone +36 1 288 40 40 Sretenskij Bulvar 6/1 Box 92161
Cao He Jing Fax +36 1 288 40 50 Office 6 SE -12008 Stockholm
CN - 200233 Shanghai e-mail [email protected] RU -101000 Moscow Phone +46 8 702 50 00
Phone +86 21 64 85 04 35 Phone +7 495 621 56 66 Fax +46 8 642 45 62
Fax +86 21 64 85 33 51 India Fax +7 495 621 63 53 e-mail [email protected]
e-mail [email protected] Mettler-Toledo India Private Limited e-mail [email protected]
Amar Hill, Saki Vihar Road Switzerland
Croatia Powai Singapore Mettler-Toledo (Schweiz) GmbH
Mettler-Toledo d.o.o. IN - 400 072 Mumbai Mettler-Toledo (S) Pte. Ltd. Im Langacher
Mandlova 3 Phone +91 22 2857 0808 Block 28 Postfach
HR -10000 Zagreb Fax +91 22 2857 5071 Ayer Rajah Crescent # 05-01 CH - 8606 Greifensee
Phone +385 1 292 06 33 e-mail [email protected] SG -139959 Singapore Phone +41 44 944 45 45
Fax +385 1 295 81 40 Phone +65 6890 00 11 Fax +41 44 944 45 10
e-mail [email protected] Italy Fax +65 6890 00 12 e-mail [email protected]
Mettler-Toledo S.p.A. +65 6890 00 13
Czech Republic Via Vialba 42 e-mail [email protected] Thailand
Mettler-Toledo s.r.o. I - 20026 Novate Milanese Mettler-Toledo (Thailand) Ltd.
Trebohosticka 2283 / 2 Phone +39 02 333 321 Slovakia 272 Soi Soonvijai 4
CZ -100 00 Praha 10 Fax +39 02 356 2973 Mettler-Toledo s.r.o. Rama 9 Rd., Bangkapi
Phone +420 2 72 123 150 e-mail Hattalova 12 / A Huay Kwang
Fax +420 2 72 123 170 [email protected] SK - 831 03 Bratislava TH -10320 Bangkok
e-mail [email protected] Phone +421 2 4444 12 20-2 Phone +66 2 723 03 00
Japan Fax +421 2 4444 12 23 Fax +66 2 719 64 79
Denmark Mettler-Toledo K.K. e-mail [email protected] e-mail
Mettler-Toledo A /S Process Division [email protected]
Naverland 8 6F Ikenohata Nisshoku Bldg.
DK - 2600 Glostrup 2-9-7, Ikenohata USA / Canada
Phone +45 43 27 08 00 Taito-ku Mettler-Toledo Ingold, Inc.
Fax +45 43 27 08 28 JP -110-0008 Tokyo 36 Middlesex Turnpike
e-mail [email protected] Tel. +81 3 5815 5606 Bedford, MA 01730, USA
Fax +81 3 5815 5626 Phone +1 781 301 8800
e-mail [email protected] Freephone +1 800 352 8763
Fax +1 781 271 0681
e-mail [email protected]

ISO ISO
9001 14001
certified certified

Management System Subject to technical changes. Mettler-Toledo AG, Process Analytics


certified according to 01/2012. © Mettler-Toledo AG Im Hackacker 15, CH - 8902 Urdorf, Switzerland
ISO 9001 / ISO 14001 Printed in Switzerland. 30 031507 Phone + 41 44 729 62 11, Fax +41 44 729 66 36 www.mt.com/pro