Fire Phone and Control Panel - Spec

The document describes a Care2 emergency voice communication system from Baldwin Boxall including its features and components. The system includes a control panel, network expansion panels, various outstations, and accessories. It allows two-way voice communication during emergency situations.

Uploaded by

Thái Nguyễn
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

TỦ ĐIỆN THOẠI GỌI PHÒNG BƠM BALDWIN BOXALL CARE 2,

GỒM MÀN HÌNH LCD, ĐIỆN THOẠI KHẨN, NGUỒN VÀ ACQUY

Care2 EVC
Compliant to BS5839-9:2021

Care2 is a radial wired emergency voice


communication system built to the high
standard you expect from Baldwin Boxall.
It is stylish, versatile and easy to use and
offers an alternative to our well-established
loop-wired Omnicare range.

CARE 2

FEATURES: BENEFITS:

• Care2 is an all-in-one Emergency Voice Communication • Stylish, versatile and simple to navigate and control.
(EVC) system.
• Suitable for small or large systems - fully networkable.
• Fully monitored and battery-backed (24 hours quiescent
• Monitored roaming telephone handsets - enables use
and three hours functional).
with confidence.
• Remote units are wired in a radial (star) configuration
• System configuration via SD card, front panel or PC
using two core (fire resisting enhanced/non-enhanced)
connection.
cable.
• Facilitates clear communication during an emergency
• Fully networkable. Networked panels are wired in a loop
event.
configuration using 2 x two core (fire resisting enhanced)
cable. • Ideal for retro-fitting old star-wired systems.
• In the event of a break in the network loop, the system • Quality built, robust system.
will continue to function.
• Activity/fault log.
• All outstations are powered from the line, including the
• Outstations, including toilet alarms, powered directly from
roaming telephone enclosure and disabled toilet alarms.
the line - no local power needed.
• Optional link to fire detection system prevents hoax
• Any combination of outstation on one system.
disabled refuge calls (C2CFPE required). Firefighter,
roaming telephones and toilet alarms remain active.
• Speech steered; disabled refuge outstations.
• Full duplex speech; firefighter and emergency/steward
telephones.
• Any combination of the following outstations can be
installed on a single system:
• Disabled refuge (Type B outstations).
• Fire telephones (Type A outstations).
• Steward (emergency) telephones (Type A
outstations).
• Roaming telephones.
• Disabled toilet alarms.

EMERGENCY VOICE COMMUNICATION


RADIAL WIRED SYSTEM
Care2 System Control

CONTROL / SLAVE PANEL: NETWORK EXPANSION PANEL (NEP):

• Unique design and easy to operate using the rotary • Facilitates expansion of the Care2 system.
encoder and clear LCD screen.
• Fit up to 15 NEPs on a network (or fourteen if installing
• The rugged red handset (with hearing aid compatible two ‘control’ panels), enabling systems of 256
earpiece) is mounted in a lockable compartment. outstations. (If you have a requirement for a larger
• System configuration is stored on an SD card and can system, please contact our sales department to discuss).
be modified either with a PC (via Ethernet or directly onto
• The NEP is supplied as a 4-way unit as standard. Simply
the SD card) or without (via the encoder and display).
increase to 8, 12 or 16-way by fitting C2CEK4 line cards.
• Includes a fault relay for indication at the fire panel. (Each NEP is fitted with a C2CN card).

• The system can be connected to a local fire panel using • For initial system set-up and local testing (prior to
a C2CFPE interface module. connection to the network) a ‘roaming telephone’ can be
temporarily connected to an internal socket.
• Two of these panels can be installed on a networked
system (fit C2CN cards). One panel will act as a ‘slave’ • The status of local outstations can be viewed by using
unit. The ‘slave’ unit can be activated as the ‘master’ if the rotary encoder and LCD screen.
required (typically during an emergency).

EXPANSION CARDS & MODULES: REMOTE LAMP BUZZER:


4-way line card (C2CEK4): • Provides a visible and audible
• Each module enables the addition of signal of a call on the Care2
four outstations. system.
• Add these modules to the control • Ideal solution for systems where
panel(s) and/or NEPs as required. the control panel is mounted in an
• Up to three modules can be added per unmanned area.
panel/NEP.
• Uses the output on the master
Network card (C2CN) - includes fire panel panel with adjustable delay.
interface & Ethernet connection ability:
• Stainless steel finish.
• Add one to each control panel for including
on a networked system.
DISABLED REFUGE OVERRIDE SWITCH:
Fire panel interface card (C2CFPE) - includes
Ethernet connection ability: • As an option, the disabled refuge outstations on a Care2
• Optional module which fits in the control panel system can be kept in ‘standby mode’ until required
(not required if a C2CN has been fitted). in an emergency. (Connection to the fire panel via a
C2CFPE card is required).
• Use to keep disabled refuge outstations
in ‘standby’ mode until activated by the • A system in standby mode will need to be activated
fire panel. occasionally, such as for routine testing. An override
• Add for connection to remote lamp/buzzer (BVOCCA). switch (BVCRBG) can be used for this purpose.
Care2 Outstations

DISABLED REFUGE REMOTE UNIT: IP65 RATED ENCLOSURE:

• Provides two-way communication • Enables mounting of refuge remote


between building management in external areas such as car parks,
and person(s) occupying balconies etc.
a ‘Refuge Area’ during an
emergency evacuation - typically • Green, surface mount enclosure.
a fire.
• Takes one C2RRG remote unit.
• User simply presses the button to
initiate call (occupy area). Further
communication is hands free at the refuge point or by PLASTERBOARD BACK BOX:
the end user at the control panel.
• Enables ‘first fix’ in plasterboard for
• Type B outstation. the disabled refuge remote.
• Calls are reset at the control panel when the refuge area • Green or stainless steel options (bezel
occupant has been evacuated to safety. colour).
• The unit has an output to feed an external induction loop
amplifier.

• Disabled refuge outstations on the system are


permanently ‘active’. As an option (by fitting a C2CFPE or
C2CN to the control panel) they can be set to ‘standby’ STEWARD / EMERGENCY TELEPHONE:
mode until activated by the fire panel.
• Designed for sports venues and stadia, the
steward telephone has the same facilities
as the fire telephone.

ĐIỆN THOẠI KHẢN ĐẶT TRONG PHÒNG


FIRE TELEPHONE: BƠM BALDWIN BOXALL, MÀU ĐỎ, BAO
GỒM TỦ BẢO VỆ MÀU ĐỎ
• Telephone handset in a metal
enclosure. Used by fire officers/
building control during an emergency,
such as a fire.

• Assists with the efficient evacuation of


a building.

• Robust red handset with hearing aid


ROAMING TELEPHONE:
compatible earpiece (T-coil).
• Robust red handset with
• Type A outstation. hearing aid compatible
earpiece.
• Robust handset in heavy duty
enclosure. • Any number of jack sockets
can be daisy chained (up to
• Provides clear, full duplex, two-way communication with 500m. EOL resistor required in end unit). (One handset
the control panel. operational per line at any one time).
• Push door or slot lock versions available. • The enclosure features a lockable glass door and stores
up to six handsets (order separately).
• Conference facility for fire and roaming telephones via
control panel (recommended maximum of five including • Handsets in the enclosure are monitored at all times
the control panel). (green reassurance LEDs).

• Calls are initiated by simply opening the door. • Jack sockets are flush mounting (backbox required).

L E A D I N G T H E W AY T O S A F E T Y
Disabled Toilet Alarm for EVC

DISABLED TOILET ALARM:


• The 3-part toilet alarm is connected directly to the Care2 control panel (or NEP)..

• Powered from the line (does not require local power).

• Fully compliant to BS8300:2009.

• Up to two toilet alarm kits can be connected to one line (will show as one point on the
panel).

• Each DTAKIT comprises:

• Ceiling mounted pull switch (with two ‘G’ pulls).

• Reset button with LED and (optional) sounder.

• Over-door triangular lens with integral sounder.

• WC self-adhesive sign.

• Caller reassurance facility (the sounder pulses faster when the call is accepted at the panel).

IP65 RATED TOILET ALARM:


• Compatible with the DTAKIT items.

• Surface mounting, moisture resistant units.

• Suitable for installation in wet rooms, shower rooms, etc.

• Products available include:

• Pull cord. NEW


• Call button. Ideal for installation in
showers & wet rooms.
• Reset button.

• Call & reset button.

ASSISTANCE CALL & TOILET ALARM ADDITIONS*:


• Other products available which are compatible with the DTAKIT are:

• Wall mounting call button.

• Call button & reset point.

• Wall mounting pull cord.

• Call button with 6.35 mm jack socket.

• All the above are available with a white or stainless steel finish.

• Enables the addition of any number of unmonitored call and/or reset points to a single over-door light. (NB only one over-
door light can be included per call zone. A working system must comprise of 1 x over-door light + 1 x call point + 1 x reset
point as a minimum.)
Building Your Care2 System

All panels are supplied


4 way as standard.
(Can be expanded to
Any combination of outstation type 8, 12 or 16 way.)
can be connected to a panel.
Enhanced 2-core 1.5 mm fire rated cable
Control panel (standard fire resisting cable may be used
Optional fire panel interface
card (C2CFPE). (This facility for some systems refer to BS5839-9:2021.
is also included on the
C2CN network card.)

2-core cable
Up to 500m (max resistance 2-core security cable.
Systems can of 40 Ohms).
Up to 2 toilet alarms
be networked
per panel call point/
line.

2 x 2-core 1.5 mm
enhanced fire-rated cable

Maximum overall length of the network is 5Km


(i.e. network ring length + cable length to furthest
outstation = <5Km).

NEP panel

Up to 16 panels can be placed on the network (2 of these can be control panels, one
of which will act as a slave unless activated as the master during an emergency).

Network & Line Cards Roaming Telephone

L E A D I N G T H E W AY T O S A F E T Y
Care2 System Information

GENERAL INFORMATION: RECOMMENDED MOUNTING HEIGHTS:


• There are three main components - control panel, network
expansion panels (NEP) and the remote units.
• Remote units are wired in a radial (star-wired) configuration. Control panel: Emergency Voice Communication
Control/NEP panels are loop wired. Control Panel

• Two control panels can be installed on a networked system


(the second one will serve as a ‘slave’ unit unless activated as
the ‘master’ during an emergency).
• Any combination of remote units can be connected to a
control/NEP panel.
• Any number of jack sockets (for the roaming telephone) can 1400-1500 mm
be daisy chained (up to 500m; EOL resistor required in end
unit). One handset will be operational per line at any one time.
• Outstations and control/NEP panels can be surface mounted
or flush mounted with optional bezel. Back boxes are required
for the roaming telephone jack sockets, toilet alarm reset and
overdoor light.
• The control console is typically wall mounted in a central
control room. Fire & emergency telephones:
• Remote units are wall mounted in locations such as refuge Type A
areas, stairwells, fallback positions, corridors and other
‘gathering’ points, at a height easily reached by users.
• All outstations are powered from the line, including the
disabled toilet alarms and roaming telephone handset 1300-1400 mm
enclosure.
• System configuration is stored on an SD card and can be
modified either with a PC (via Ethernet or directly onto the SD
card) or without (via the encoder and display).
• Up to two disabled toilet alarms (Baldwin Boxall DTAKITs) can
be connected to one line. (Or one toilet alarm with two ceiling
pulls).

CABLING: Disabled refuge outstations:


Type B
• Disabled refuge, firefighter and roaming telephones - two
core, fire resisting, enhanced (or non-enhanced may be
considered for non fire fighting. (Refer BS5839-9:2021).
900-1200 mm
• Disabled toilet alarms - two core, fire resisting to first DTAKIT
overdoor light. Then two core security.
• Network loop - 2 x two core fire resisting cable (enhanced
recommended).
• Up to 500m cable run between each remote unit and the
control/NEP panel.
• Up to 500m cable run between each control/NEP panel.
• Maximum overall length of the network is 5Km (i.e. network Disabled toilet alarm pull:
ring length + cable length to the furthest outstation = <5Km).
G

G
800-1000 mm
100 mm
Care2 Product Codes

SYSTEM CONTROL DISABLED TOILET ALARM


Black Stainless Steel White Stainless Steel
4-way control panel C2CB4 C2CS4 3 part kit DTAKIT DTASKIT
4-way NEP C2CBNEP C2CSNEP Ceiling pull DTACP DTASKIT
4-way line card C2CEK4 Over-door light DTAODL DTASODL
Flush mount bezel C2CBZ C2CSZ Reset point DTARP DTASRP
Fire panel interface C2CFPE ASSISTANCE CALL
Network expansion card C2CN Call button DTACB DTASCB
Spare key KEYBVE Call button + reset button DTACBRP DTASCBRP
Remote lamp buzzer BVOCCA Wall mount pull cord DTACPW DTASCPW
Disabled refuge override BVCRBG Call button + 6.35mm jack DTACBJ DTASCBJ
DISABLED REFUGE IP65 RATED TOILET ALARM
Green Stainless Steel Grey
Refuge remote C2RRG C2RRS Pull cord DTACPM
Flush mount bezel BVCRMGRN BVCRMSS Call button DTACBM
Plasterboard back box C2RRGPB C2RRSPB Reset button DTARPM
IP65 rated enclosure C2RRBIP Call button + reset button DTACBRPM
FIRE TELEPHONE
Red Stainless Steel
Push door C2FTRP C2FTSP
Slot lock door C2FTRL C2FTSL
Flush mount bezel C2FTRZ C2FTSZ
STEWARD TELEPHONE
Green
Push door C2ETGP
Slot lock door C2ETGL
Flush mount bezel C2ETGZ
ROAMING TELEPHONE
Black Stainless Steel
Lockable enclosure C2RTEB C2RTES
Flush mount bezel C2CBZ C2CSZ
Spare key KEYBVE
Telephone handset C2RTH
Jack socket - UK C2RTJUK
Jack socket - American C2RTJA

L E A D I N G T H E W AY T O S A F E T Y
Care2 System Specification
Control panel (& Emergency Roaming Roaming
Disabled Firefighter Disabled toilet
network expansion / Steward telephone jack telephone
refuge telephone alarm
panel) telephone socket enclosure
C2CB4 / C2CS4 C2RRG C2FTRP/L C2ETGP C2RTJUK C2RTEB DTAKIT
Product codes
C2CBNEP/C2CSNEP C2RRS C2FTSP/L C2ETGL C2RTJA C2RTES DTASKIT
200-230V AC
Power supply 20-30V DC self powered from line
50-60Hz
Power consumption 75VA max

Humidity range 95% non-condensing

Temperature range -10°C to +40°C


4 x green LEDs:
Power, call, RR active,
1 x red LED: Triangular lens on
healthy.
‘status’ 1 x red LED: 1 x green LED: 1 x green LED: over-door light/
Indicators include 3 x yellow LEDs: -
1 x green LED: status indicator status indicator status indicator sounder. 1 x red
Processor restart,
‘system ok’ LED on reset.
common fault,
processor fault.
Dimensions UK: 85 x 85
430 x 310 x 130 134 x 134 x 44 130 x 330 x 75 130 x 330 x 75 430 x 310 x 130 Max: 85 x 85
mm W x H x D A: 41/2“x 23/4“
Bezel dimensions
470 x 350 154 x 154 170 x 370 170 x 370 - - -
mm W x H
Bezel cut out mm 440 x 320 136 x 136 136 x 336 136 x 336 - - -
Back box UK (mm): 85 x
Single gang (n/a
requirements - - - - 85 x 35 -
white ceiling pull)
mm W x H x D A: 4“x 21/8“x27/8“
C2CB4/NEP - 9 kg DTAKIT 0.34 kg
Weight 1 kg 2.5 kg 2.5 kg 0.5 6.5 kg
C2CS4/NEP - 8.6 kg DTASKIT 0.48 kg
RAL 9005 / RAL 6024 / RAL 3020 / RAL 9005 / White plastic /
Finish RAL 6024 SS grade 304
SS grade 304 SS grade 304 SS grade 304 SS grade 304 SS grade 304
Knockouts/cable entry points:

Top of unit 23 x 20 mm 4 x 20 mm 1 x 20 mm 1 x 20 mm - 23 x 20 mm

Bottom of unit - 4 x 25 mm - - - - -

Mounting height 1.4 - 1.5 m 0.9 m - 1.2 m 1.3 - 1.4 m 1.3 - 1.4 m - - Various

Please note: Stainless steel products are not intended for use in humid areas.

Baldwin Boxall Communications Ltd


Wealden Industrial Estate, Farningham Road,
Crowborough, East Sussex, TN6 2JR, United Kingdom

T: +44 (0) 1892 664422


E: [email protected]
W: www.baldwinboxall.co.uk
WE RESERVE THE RIGHT TO CHANGE THE TECHNICAL SPECIFICATION WITHOUT PRIOR NOTICE. DOC NO: 1.0043.10.21