Aiditec Systems Lightning Protection Systems
Aiditec Systems Lightning Protection Systems
SYSTEMS
TECHNICAL ADVICE BUDGET WITHOUT COMMITMENT
Resolution of doubts, queries and issues related to Contact us, tell us what you need and receive your
lightning rods, accessories and/or grounding. estimate for free without obligation.
PROJECTS TRAINING
Preparation of technical documentation for all types of Training courses and webinars for all types of
lightning protection projects. professionals in the sector.
I N S TA L L AT I O N O F E A RT H I N G S R I S K S E VA L U AT I O N
With guarantees of compliance with the UNE 21186 Determination of risk level and protection level according
standard and using high quality materials. to the UNE 21186 or CTE SU 8 standards.
TESTING C E RT I F I C AT I O N
Verification of operation, with specialized devices, of all Manufacturer certification service for any related
the elements of the installation. element.
ABOUT US
Each product that leaves our facilities goes through different quality tests, thus ensuring the proper functioning
of all of them, following as a guide the units tested and certified by the Technological Institute of Energy (ITE),
an accredited and independent laboratory. We are constantly working on new products, constantly investing
in R+D+I, knowing that innovation is our flag and a necessity for our customers.
We have a presence in the 5 continents, but we do not stop there, we continue in continuous international
expansion, offering advice and training to universities and companies that requier it.
In addition, we actively participate as members of the standarization workgroups in the field of lightning
protection.
R + D + I
D E S I G N A N D M A N U FA C T U R I N G
European technology
Our products meet all the requirements established in current regulations and have been designed,
manufactured and verified according to the most demanding quality standards. In addition, all the materials
used are of spanish origin.
We have certifications of accredited bodies, official and independent to give maximum guarantees. All our
lightning rods have a lifetime warranty.
ISO 9001
This certification guarantees that Aiditec Systems, S.L. complies with the quality according to the ISO
9001:2015 standard in all work procedures, ensuring our company’s commitment to the quality of all our
products and services. In addition, this certification helps us identify and address risks, improve performance
and operate more efficiently, as well as demonstrate high levels of service quality when applying for new
contracts and markets.
I N T E R N A C I O N A L I Z AT I O N
Our headquarters are in Valencia (Spain) but we operate through a network of local distributors in more than
25 countries, adapting to the needs and demands of each place.
Our distributors are highly qualified and, in addition, we offer them a support plan that includes continuous
training, technical support, sales and marketing support tools.
SERVICES
Our engineering team is qualified to carry out lightning protection projects, analyze the situation and design
the most suitable solution to provide the most effective protection.
ADVICE
Technical advice to all types of professionals in the sector for the correct installation of protection systems
against atmospheric discharges.
TRAINING
Training courses and webinars for all types of proffesionals who want to acquire knowledge in everything
related to this sector.
We have a technical department for the development of the different protection calculations. In addition,
anyone who wants can make their own risk calculation on our website, as well as the calculation for the
selection of surge protectors.
LIGHTNING PROTECTION
The installation of a lightning protection system designed and installed in accordance with the standards
minimizes the consequences of lightning as much as possible. On the other hand, to keep the system in
perfect condition over time, it will be necessary to carry out periodic reviews and maintenance.
There are different reasons for installing a lightning protection system, but they could be reduced to two
fundamentally:
1. Having a lightning protection system is the best option to protect people, animals, structures, machinery
and facilities against this natural phenomenon.
2. To comply with the norms that regulate the installation of these systems. According to these standards,
in some cases the installation will be mandatory, necssary or recommended. To determine this question,
the calculation of the risk index must be performed. Different factors are taken into account in this
calculation, but basically two are taken into account; the probability of impact and the consequences
derived from it. Among the structures in which installation of a lightning protection system will be
necessary are:
• Buildings or open areas with public attendance.
• High-rise buildings.
• Constructions or tanks in which toxic, radioactive, flammable or explosive substances are handled
or contain and ATEX areas.
• Buildings containing especially vulnerable or valuable equipment or documents.
• In general, structures used for commercial, industrial, agricultural, administrative or residential
purposes.
In addition, it should be borne in mind that insurers recommend the installation and maintenance of these
protection systems to be able to adjust the amounts of the insurance, since in this way understand that the
user is using the appropiate means to protect himself from lightning and its effects.
E A R LY S T R E A M E R E M I S S I O N
With this increase of potential, two things happen at the same time; the first is that a downwards stream
is created from the clouds to the ground, and the second is that an upward artificial stream is created by
lightning rod. This ascending stream intercepts the descending one, guiding the electric discharge through
the lightning rod and conducts it to the ground safely.
The time that the upward stream of an ESE lightning rod forward to a stream created by any passive element,
such as a Franklin rod, is what determines the radius of protection. This is what os known as advance time in
priming (∆t). Therefore, there are different ESE models with different advance times depending on the meters
of protection needed in each case.
Index
ESE LIGHTNING RODS............................................................08
ADVANCE +...................................................................................................................10
SIGMA +..............................................................................................................................12
ELECTRON E15..................................................................................................................................14
PA S I V E L I G H T N I N G R O D S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 6
ACCESSORIES......................................................................20
GROUNDING....................................................................36
MEASURING DEVICES.............................................................42
AS Tester............................................................................................................................................44
ADT Counter......................................................................................................................................46
SPD....................................................................................................................52
SPU.....................................................................................................................59
SELF-COMPSUMPTION AND ELECTRIC VEHICLE............................................................................61
ESE LIGHTNING RODS
ADVANCE+
The ADVANCE+ lightning rod with priming device (ESE) is the best protection with the latest
technologies incorporated and the best guarantee of operation. This device has successfully passed
the test based on the UNE 21186, NFC 17102, and NP 4426 standards for lightning rods with a
priming device:
DIMENSIONALS
Ensures that the dimensions are normalized.
ADVANCE IN PRIMING
Guarantees the protection radius.
AS a result of the research carried out and the R&D projects developed, the ADVANCE+ lightning rod
incorporates the following new technologies:
The ESE ADVANCE+ guarantees the operation of its priming device and its effectiveness in protection in
extreme rain conditions thanks to the “ISOLATED RAIN” system.
This system guarantees total isolation in adverse atmospheric conditions provided by the ELECTRODE
IONIZATION VAULT. This vault prevents the rain from putting the metal body of the lightning rod (at
atmospheric potential) in electrical contact with the metal shaft (at ground potential).
When an ESE does not have this insulation guarantee and adverse atmospheric conditions occur, such
as heavy rain, electrodes with different potentials can come into contact and cause a short circuit in the
ignition device that prevents the lightning rod from offering the necessary safety, drastically reducing
your radius of protection.
> INSTALLATION
The installation of the ESE ADVANCE+ must be carried out of following the indications of the Technical
Building Code (CTE) and standards UNE 21186, NFC 17102, and NP 4426. “Protección contra el rayo:
Pararrayos con dispositivo de cebado”.
All models of the ESE ADVANCE+ have successfully passed the tests based on current regulations. The results of the laboratory test were
much higher, but by regulation, we certify the following advance times:
> PROTECTION RADIUS OF THE ESE ADVANCE+ FOR A HEIGHT OF 6 METERS IN RELATION TO THE PLANE TO BE PROTECTED
All ADVANCE+ ESE carry an INTERNATIONAL LIMITED LIFETIME WARRANTY against all manufacturing defects. More info about our
product warranty at: www.aiditecsystems.com/warranty
SIGMA+
The ESE SIGMA+ is an incredibly effective and highly competitive premium protection system.
This device has successfully passed the tests based on the UNE 21186, NFC 17102, and NP 4426
standards for lightning rods with priming device:
DIMENSIONALS
Ensures that the dimensions are normalized.
ADVANCE IN PRIMING
Guarantees the protection radius.
As a result of the research carried out and the R&D projects developed, the SIGMA+ lightning rod
incorporates the following new technologies:
> INSTALLATION
The installation of ESE SIGMA+ must be carried out following the indications of the Technical Building Code (CTE) and standards UNE
21186, NFC 17102, and NP 4426. “Protection against lightning: lightning rod with priming device”.
All ESE SIGMA+ have successfully passed the tests based on current regulations. The results of the laboratory test were much higher, but
by regulation, we certify the following advance times:
> PROTECTION READIUS IN METERS FOR A HEIGHT OF 6 METERS IN RELATION TO THE PLANE TO BE PROTECTED
ALL ESE SIGMA+ carry an INTERNATIONAL LIMITED LIFETIME WARRANTY against all manufacturing defects. More info about our
product warranty at: www.aiditecsystems.com/warranty
ELECTRON E15
Due to its small size and incredible performance, the ELECTRON E15 lightning rod with priming
device (ESE) is perfect for protecting structures and small areas such as towers, antennas, or single-
family homes. This device has successfully passed the tests based on the UNE 21186, NFC 17102,
and NP 4426 standards for lightning rods with priming device:
DIMENSIONALS
Ensures that the dimensions are normalized.
ADVANCE IN PRIMING
Guarantees the protection radius.
As a result of the research carried out and the R&D projects developed, the ESE ELECTRON E15
incorporates the following new technologies:
> INSTALLATION
The installation of the ESE ELECTRON E15 must be carried out of following the indications of the
Technical Building Code (CTE) and standrds UNE 21186, NFC 17102 and NP 4426 “Protection
against lightning: lightning rod with priming device”.
The ESE ELECTRON E15 has successfully passed the tests based on current regulations. We can certify the following lead time:
> PROTECTION RADIUS IN METERS FOR A HEIGHT OF 6 METERS IN RELATION TO THE PLAN TO BE PROTECTED
All ESE ELECTRON E15 carry an INTERNATIONAL LIMITED LIFETIME WARRANTY against all manufacturing defects. More info about
our product warranty at: www.aiditecsystems.com/warranty
Protected areas
Unprotected sensitive areas
PA S S I V E R O D S
The Franklin rod is a device designed to protect buildings, structures and people against the dangerous effects of lightning. It was invented
by Benjamin Franklin in the 18th century and has been widely used ever since to prevent damage from lightning strikes from storms.
The Frranklin rod consists of several esential parts. The main piece is a conductive metal rod, generally made of cooper or stainless steel
alloys, which is installed in the highest part of the building or structure to be protected. The rod rises above the highest point of the ciling,
allowing it to draw lightning to itself.
As a thunderstorm approaches, the electric and magnetic fields generated by atmospheric charges cause the pointed end of the lightning
rod to ionize the surrounding air. This ionization forms a low-resistance path to earth for the electrical current from lightning, preventing
it from damaging the structure it protects.
Lightning current travels through the conductor to a down conductor, which in turn is connected to a network of conductors buried in the
ground, known as a grounding system. This system dissipates lightning energy safely into the ground, preventing it from damaging the
buildings or starting fires.
It is essential to note that the Franklin rod does not prevent lightning strikes, but rather provides a controlled path for the current to flow
to earth. Additionally, multiple arresters can be installed on large buildings or large areas to improve lightning protection.
Over the years, Franklin rod have proven to be highly effective in protecting against lightning, greatly reducing structural damage and risks
to people. However proper design ans intallation are essential to ensure proper operation. Therefore, it is recommended that a qualified
proffesional perform the installation ad periodic maintenance of the system to ensure optimal protection against the dangers of electrical
storms.
Franklin rods for protection against lightning. It can be used as a sensor elementt or be part of passive
protection systems. Includes a brass adapter piece for Ø 45 mm and internal connection with round
conductor Ø 8/10 mm (50/70 mm2).
PA S S I V E R O D S
SCHOOL BUILDING
ACCESSORIES
SPARK GAP
Lightning protection regulations indicate that each lightning rod must be have its own ground connection and independently must have a
velue below 10 ohms. On the other hand, they also recommend linking the lightning rod ground connections to other ground connections
to avoid potential differences.
Direct connections can be made, but it is always better to do it with spark gaps for different reasons:
• The facilitate that the main path of the lightning current is through the grounding of the lightning rod.
• It maintains the different ground connections at the same potential, avoiding dangerous spark jumps through unwanted areas, but
only at the moment of discharge, because in normal state it keeps them separated.
• They prevent some sensitive systems or equipment from being influenced by these direct connections.
• They protect against corrosion that can occur in some cases by directly connecting different ground connections.
Spark gaps are also used to protect antennas, metal structures, tanks, etc.
148 mm
40 mm
Ø
56
Ø 8 mm
mm
22 ACCESSORIES www.aiditecsystems.com
ACCESSORIES
Spark gap for equipotential protection for connection to lightning rods and grounding.
AS500550
It is connected to the antenna mast to ensure equipotential bonding between the metallic elements, thus avoiding dangerous sparks
between the lightning protection system and the antenna mast, which could even cause fire and damage to the structure.
+
AS600550 AS700150
www.aiditecsystems.com ACCESSORIES 23
ACCESSORIES
ACCESSORIES
ADAPTATION PIECE
> ADAPTATION PIECE WITH INTERNAL CONNECTION
Adaptation piece for joining the lightning rod with the mast and internal connection with the down conductor.
AS700100
> U-BOLT
U-Bolt for joining the lightning rod with the mastt and with a stainless steel flange for the external connection with the down conductor.
AS700150
24 ACCESSORIES www.aiditecsystems.com
ACCESSORIES
ACCESSORIES
MASTS
> WALL-MOUNTED MAST
Mast made of galvanized steel or stainless steel (optimal for highly corrosive environments) with a diameter
of 45 and a thickness of 2 mm to be attached to buildings or structures with 2 supports (except 8 m masts
that are fixed with 3 supports + guys).
Masts to be installed on a concrete block embedded in the ground, made of galvanized steel and studied to
withstand winds of up to 140 Km/h. AS700310
www.aiditecsystems.com ACCESSORIES 25
ACCESSORIES
ACCESSORIES
ANCHORAGES
26 ACCESSORIES www.aiditecsystems.com
ACCESSORIES
Standard anchor to embed or screw. Manufactured in a “U” profile of 20 x 40 x 20 and thickness of 3 mm.
Anchor for wleding to structures. Manufactures in a “U” profile of 20 x 40 x 20 mm and thickness of 3 mm.
www.aiditecsystems.com ACCESSORIES 27
ACCESSORIES
Anchors for fixing masts to turrets and lattices. Manufactured in a “U” profile of 20 x 40 x 20 and 3 mm thick.
28 ACCESSORIES www.aiditecsystems.com
ACCESSORIES
ACCESSORIES
CONDUCTORS
> TAPE CONDUCTOR
Bara flat conductors are recommended by lightning protection regulations as downstream and ground
conductors.
Bare solid conductors are recommended by lightning protection regulations for use in highly corrosive
environments.
Bare stranded conductors are recommended by lightning protection regulations for use in highly corrosive
environments.
www.aiditecsystems.com ACCESSORIES 29
ACCESSORIES
ACCESSORIES
Clamps for fixing flat conductors to buildings and strcutures. Includes plug and screw.
Staples for fixing round conductors to buildings and structures. Includes plug and screw.
> SEPARATORS
30 ACCESSORIES www.aiditecsystems.com
ACCESSORIES
ACCESSORIES
AS600640
Reference Material For conductor Type
AS600640 Stainless steel Ø 6 to 11 mm Adjustable 170/240 mm
AS600641 Stainless steel Ø 8 mm Extensible 170/280 mm
Adjustable 120/240 mm
AS600642 Stainless steel Ø 6 to 10 mm
(for ridge cap) AS600642
Adjustable 120/240 mm
AS600643 Cooper Ø 6 to 10 mm
(for ridge cap)
AS600643
Pressure.
AS600660 Stainless steel Ø 8 mm
For 8/10 mm thickness
AS600641
Pressure.
AS600661 Stainless steel Ø 8 mm
For 15/20 mm thickness
AS600670 Stainles steel Ø 6 to 10 mm For sandwich type roofs
AS600700 Stainless steel No include fixing For pipes from Ø 60 to 150 mm
AS600670
AS600720 Stainless steel No include fixing For pipes from Ø 60 to 150 mm
AS600740 Cooper No include fixing For pipes from Ø 60 to 150 mm
Complies with: EN 50164, UNE 21186, NFC 17102 and NP 4426 AS600700
www.aiditecsystems.com ACCESSORIES 31
ACCESSORIES
ACCESSORIES
Universal connector for round stainless steel conductors with multiple connection methods.
Cross connector for flat and round conductors and test link. AS600823
> T CONNECTOR
Complies with: IEC 62305, EN 50164, UNE 21186, NFC 17102 and NP 4426
> LINEAR
> PARALLEL
32 ACCESSORIES www.aiditecsystems.com
ACCESSORIES
> TO GUTTER
Complies with: IEC 62305, EN 50164, UNE 21186, NFC 17102 and NP 4426
> BIMETALLIC
Bimetallic connector with an intermediate plate for flat and round conductors.
> KS
Complies with: IEC 62305, EN 50164, UNE 21186, NFC 17102 and NP 4426
www.aiditecsystems.com ACCESSORIES 33
ACCESSORIES
ACCESSORIES
OTHER ACCESSORIES
> GUARD TUBE
Tube for the mechanical protection of the down conductor of the protection system.
Fastening and tensioning of masts by means of steel winds to prevent falls due to the effect of the wind.
34 ACCESSORIES www.aiditecsystems.com
ACCESSORIES
NOTE
This catalog only includes the most common accessories for a complete installation. If you need a product with different
characteristics, contact os and and our technical department will advice you on the most appropriate choice.
Tel.: +34 963 842 957
Email: [email protected]
www.aiditecsystems.com ACCESSORIES 35
GROUNDING
GROUNDING
ELECTRODES
> ACTIVE ROD*
Active electrode with moisture exchanger and drainage of ionic compound especially indicated for carrying
out grounding in very high resistivity terrain. Includes stainless steel connector for conductors from Ø 8 to
10 mm and flat up to 30 mm.
Complies with: IEC 62305, UL 467, EN 50164, UNE 21186, NFC 17102 and NP 4426
Rigid graphite electrode indicated for making earth connections in particularly aggressive terrain. Includes
stainless steel connector for conductors from Ø 8 to 10 mm and flat up to 30 mm.
Electrodo de acero cobrizado para tomas de tierra con un alto grado de resistencia a la corrosión.
Cumple con: BS 7430, BS 6651, UL 467, NFPA 780, IEC 62305, EN 50164, UNE 21186, NFC 17102 y NP 4426
Electrodo de acero inoxidable para tomas de tierra con un alto grado de resistencia a la corrosión.
38 GROUNDING www.aiditecsystems.com
GROUNDING
GROUNDING
> STAPLES
Reference Material For electrode For round conductor For flat conductor AS500390
www.aiditecsystems.com GROUNDING 39
GROUNDING
GROUNDING
EARTHING IMPROVERS
> WELLCONDUCTOR
Totally ecological, non-corrosive, very hygroscopic and fast-acting ionic compound that substantially
improves the conductivity of the ground.
Plates with connector for conductors recommended as grounding electrodes to obtain a very low resistance
in very rocky terrain due to the large surface in contact with the ground.
AS500411
Reference Material Dimensions For conductor
AS500401 Copper 500 x 500 x 1,5 mm 6
AS500411 Copper 500 x 500 x 1,5 mm 8
Complies with: EN 50164, UNE 21186, NFC 17102 and NP 4426
Polypropylene box to locate and organize the earth connections. Chemical and UV resistant.
Stainless steel connection bridge for the equipotential bonding of earthing electrodes and round conductors
of Ø 8/10 mm and flat conductors up to 30 mm wide.
40 GROUNDING www.aiditecsystems.com
GROUNDING
GROUNDING
EQUIPOTENTIAL BONDING
> BONDING BAR
Fixed connection points to connect to the framework of the structure or ground system.
NOTE
This catalog only includes the most common grounding accessories. If you need a product with different characteristics, contact
us and our technical department will advise you on the most appropiate choice.
Tel.: +34 963 842 957
Email: [email protected]
www.aiditecsystems.com GROUNDING 41
MEASUREMENT DEVICES
MEASUREMENT DEVICES
AS TESTER PRO
> LIGHTNING ROD TESTER WITH PRIMING DEVICE
The AS TESTER PRO is a high-tech portable measurement device that performs an automatic and complete test of the operation of
lightning rods with priming device. It is valid for all ESEs manufactured by Aiditec Systems, S.L.
Connection terminals
Controls
Battery
location
Power
button
Reference AS600999
Dimensions 145 x 95 x 35 mm
Weight 276 gr.
Maximum output voltage 15 V
Lightning rod ignition test 0.3 mA ± 2%
Autonomy 1000 test
Battery 3,7 V / 1800 mAh
Operating temperature - 20ºC ... + 65ºC
Complies with: EN 62561-6, EN 50164-6 and UTE C 17-106
Functioning
> INSTRUCTIONS
> CONNECTION
The measurement must always be made between 2 existing potentials in all lightning rods with priming
devices (ESE):
• ATMOSPHERIC POTENTIAL (tip and body)
• EARTH POTENTIAL* (axis)
*If the measurement is made with the lightning rod installed, the connection to ground potential can be made
on the mast or the downpipe, since both elements would be attached to the axis of the lightning rod.
> SAFETY
WARNING
The AS TESTER PRO lightning rod tester only guarantees the proper functioning of the priming device but not the physical integrity
of the lightning rod, so a positive result in a lightning rodd that has suffered physical damage does not mean that it maintains
its condition. Level of coverage, since this does not depend only on the priming device, but also on physycal parameters, so to
guarantee the level of coverage, a visual inspection of the physical integrity of the lightning rod is also required.
MEASUREMENT DEVICES
ADT COUNTER
> THE MOST VERSATILE, COMPLETE AND EASY TO INSTALL LIGHTNING METER
The ADT Counter counts and records the direct strikes and surges of a lightning protection system.
It is a device thet does not intervene in the operation of the protection system, but it is undoubtedly a very important element, because it
is the only way of knowing that the system has suffered a lightning strike and that a revision of the system must be carried out to verify
that everything is in correct condition and we continue to be protected.
Due to its design and its materials, it is robust, reliable and autonomous. It does not need external power supply and is compatible with
any lightning rod.
> BENEFITS
> LOCATION
The device must be located at any point on the downspout between the protection tube and the mast. It is inserted in the downpipe with
less ohmic resistance or, failing that, in the straightest and most direct to ground.
Reference AS600920
Dimensions 82 x 69 x 45 mm
Weight 285 gr.
Minimum threshold current (Itc 8/20 µs) 1 kA
Withstand and counted current (Imcw 10/350 µs) 100 kA
For conductor up to Ø 15 mm
For tapes up to 60 x 10 mm
Operating temperature - 20ºC ... + 65ºC
Complies with: EN 62561-6, EN 50164-6 and UTE C 17-106
El contador de impactos de rayos ADT Counter ha superado con éxito los ensayos eléctricos conforme a la norma UNE EN 62561-6, de acuerdo
con los tests consecutivos de mínima corriente umbral, corriente de no detección y corriente soportada y contada.
The lightning event counter ADT Counter has successfully passed the electrical test according to UNE EN 62561-6, according to the consecutive
tests of minimum current threshold, no current detection and withtand current and counted.
CLASIFICACIÓN / CLASIFICATION
REF. AS600920
Dimensiones
82 x 69 x 45 mm
Dimensions
Peso
320 gr.
Weight
Código IP
IP-43
IP code
Temperatura de funcionamiento
- 20ºC ... + 65ºC
Operating temperature
Para conductor redondo Hasta / Up to
For round conductor Ø 15 mm
Para conductor plano Hasta / Up to
For flat conductor 60 x 10 mm
Mínima corriente umbral (Itc) con onda 8/20
1 kA
Minimum current threshold (Itc) with wave 8/20
No detección con Itc/2
0,5 kA
No detection (Itc/2) with wave 8/20
Corriente soportada contada (Imcw) con onda 10/350
100 kA
Withstand current and counted (Imcw) with wave 10/350
Cualquier punto de la bajante entre
Ubicación el tubo de protección y el mástil.
Location Any point on the downspout between
the protection tube and the mast.
Garantía limitada internacional 1 año
Limited international warranty 1 year
It is necessary to install surge protection devices at least in the main electric switchboards of facilities equiped with lightning ross,
especially in those installations closest to the lightning rod.
In the case of high resistivity of the terrain, the need for installing overvoltage protection is even more crucial. The grater earth potential
differences, the higher energetic impact of overvoltages will be.
• Lack of insulation: a poor isolated insulation will be reached by atmospheric discharges when lightning strikes the lightning rod.
This devices redirect energy to the ground.
• Electromagnetic fields: as a result of lightning strikes, strong currents are generated. As a result magnetic fields are induced in
every conductor nearby, such as electric, data and coaxial cables.
When lightning strikes the earth, currents may be induced in long-distance cables used for electric lines especially in large-scale facilities.
In order to avoid the loads of the installation to be damaged, surge protective devices must be installed at both ends of cables used for
the loads connection.
The higher the resistivity of the terrain, the grater the voltage gradients are and the need to protect both ends of the cable.
• Inductions: when a lightning strikes the earth, an electrical potential funnel is generated and therefore electrical potential
differences appear in the terrain. Consequently, if an electric, coaxial or data cable runs between two different potential curves,
a current will be induced thereon and affect the loads fed by this cable.
The transient overvoltages transmitted by the distribution networks have their origin the electrical distributors, line faults and mainly in
the atmospheric discharges that reach high-voltage lines.
Since the discharge lamps, variable speed drives, connection and disconnection of generators cause surges and short-term currents with
high-peak values, transient surges caused by network users and their surroundings can not be obviated.
In order to reduce incidences and avoid users, devices and facilities themeselves to be damaged, it is neccessary to install the properly
sorge protective devices for this kind of installations, at least in the main electrical switchboard and those with a high risk of suffering
the consequences of overvoltages.
• Induced atmospheric discharges on High-Voltage lines: an atmospheric discharge is the most damaging problem that you can
find in an installation. As a High-Voltage power line is the most likely place for a lightning to strike, most of the time it will reach
the installation through the electrical supply.
• Overvoltages originated in the electrical network: manoeuvres such as the switching of electric substation in electrical network
may cause micro-interruptions which are associated to transient voltage peaks that will be transmitted thrughout the whole
electrical network. As a result, the power supply of users facilities will be affected. Sometimes the value of voltage supplied by
electricity companies is higher that the maximum supported by electronic devices and consequently these are affected.
• The influence of power liads over electronics: the start or stop of engines and generators, the variable speed drives, etc.,
may produce overvoltages in the electronic devices. According to the magnitude of the overvoltage, electronic devices of the
installation may be damaged gradually or quickly.
ATMOPHERIC DISCHARGE
TO GROUND
FUNNEL OF POTENTIAL
Surge protection devices Type 1 are recommended for installations where is a high probability of atmospheric
discharges.
C O M PA C T S U R G E P R O T E C T I O N D E V I C E S
Reference Description Uc. Máx Iimp Up
AD4-400/240 Tetrapolar 255 V 100 kA 1,5 kV
AD2-400/240 Bipolar 255 V 100 kA 1,5 kV
AD1-200/240 Unipolar F-N 255 V 50 kA 1,5 kV
AD1-400/240 Unipolar N-T 255 V 100 kA 1,5 kV
Available for all types of ground systems. TT, IT, TN-S and TN-C AD1-200/240
Standards: IEC 61643-1, EN 61643-11 and UL 1449
Surge protection devices Type 1+2 are installed at the head of installations to protect and it is combined the
characteristics of Type 1 and Type 2.
C O M PA C T S U R G E P R O T E C T I O N D E V I C E S
Uc. Máx Iimp (L-N)
Reference Description In Up
(F-N / N-T) (F-N / N-T)
BD4-100/240 Tetrapolar 275 V / 255 V 12,5 / 25 kA 50 kA 1,5 / 1,8 kV
BD4-100/240 S Tetrapolar 275 V / 255 V 12,5 / 25 kA 50 kA 1,5 / 1,8 kV
BD2-100/240 Bipolar 275 V / 255 V 12,5 / 25 kA 50 kA 1,5 / 1,8 kV
BD2-100/240 S Bipolar 275 V / 255 V 12,5 / 25 kA 50 kA 1,5 / 1,8 kV BD1-100/240
Surge protection devices Type 2 are installed at the head of electrical installations and at secondary power
panels. Protect electronic and electrical equipment against transient overvoltages of origin industrial,
atmospheric and maneuvering.
Type 2+3 surge protection devices are installed in the power supply of the final receivers and combine the
characteristics of Type 1 and Type 3.
Surge protection devices for the protection of equipment that work in direct current. They protect photovoltaic
equipment against transient overvoltages of atmospheric origin and maneuver.
1. BF3 series surge protector. Surge protectors for direct current installations. They protect the
inverters and other electrical equipment against transient overvoltages that come from strings.
2. BD4-40/240 surge protector.
3. BD4-100/240 surge protector. Protects the electrical installation from transient overvoltages that
may enter through the electrical connection.
DISTRIBUTION
PANEL
INVERTER
SOLAR
PANELS
Surge protection devices for data lines protect the electronic equipment in the network of communication
against any overvoltage induced on the data lines. These surge protectors must be installed as close as
possible to the equipment to protect.
S U R G E P R OT E C T I O N D E V I C E S F O R D ATA L I N E S
Up
Reference Description Uc. Máx In I Máx IL
(L-L / L-T)
TD/5-B0 1 pair 6 Vcc 5 kA 10 kA 80/350 V 500 mA
TD/12-B0 1 pair 15 Vcc 5 kA 10 kA 150/350 V 500 mA
TD/24-B0 1 pair 28 Vcc 5 kA 10 kA 200/500 V 500 mA
TD/48-B0 1 pair 60 Vcc 5 kA 10 kA 250/500 V 500 mA
TD/110-A0 1 pair 180 Vcc 5 kA 10 kA 0,5 kV 500 mA
TD/250-A0 1 pair 275 Vcc 5 kA 10 kA 1/0,75 kV 500 mA
TD/5-B0
Standards: IEC 61643-1
For telephone
TD/110-RJ11-4 lines with 180 Vcc 2 kA 5 kA 200/500 V 0,5 A
RJ1 connector
For Ethernet with
TD/5-RJ45-8-CAT 6 RJ45 connector, 6 Vcc 2,5 kA 5 kA 15/800 V 0,5 A TD/5-RJ45-8-CAT 6-POE
Cat 6
Ethernet
6 Vcc
TD/5-RJ45-8-CAT 6-POE RJ45, Cat 6 2,5 kA 5 kA 25/600 V 0,8 A
(57 Vcc POE)
Power Over Ethernet
Standards: IEC 61643-1
Surge protection devices for coaxial cables protect electronic equipment associated with the coaxial
installation against any overvoltage induced on coaxial cables. These surge protectors must be installed as
close as possible to the equipment to protect.
NOTE
In this catalog only the most common protectors are considered. If you need protectors with different characteristics, contact us
and our technical department will advise you on the most appropiate choice.
Tel.: +34 963 842 957
Email: [email protected]
SPUs have been conceived to ensure the protection of the installations against overvoltagesm either atmospheric and industrial origin,
MF/AM harmonics and peaks associated with micro-interruptions. Optionally, the electrical installation will be protected against surges,
power interruptions and phase asymetry effects by adding a PTR4 set. This set is time and voltage programmable.
Our protection systems have been designed to protect every kind of electrical and electronic installations of any power, especially those
which have sensitive electronic devices. By installing a SPU system you are avoiding installations to be affected by: surges, permanent
overvoltages, micro-interrumptions, harmonics, undervoltages, phase asymmetry and electromagnetic compatibility.
Since not all installations are alike and they need to be protected effectively, it is necessary to adapt to their features as well as our
customers demands. In MD we offer the possibility to modify the performances of our products to siut their needs. Therefore, any device
developed by MD can be:
• Set to special supply voltages: 500 V, 690 V, etc.
• Modify the IP rating in installations that require it.
• Increase the capacity of energy dissipation in installations bound to very energetic discharges.
• Increase the frequency filtering capacity.
• Adapt them to any network tipology: biphasic, three-phase lines without neutral, IT, TT, etc.
• Incorporate acoustic alarms.
SELF-COMPSUMPTION
The SPF series equipment is specially designed for the protection of solar panel installations for self-
consumption that are connected to:
This series of protectors for photovoltaic systems are intended to protect against overcurrents and
overvoltages caused by lightning strikes in the continuous part of direct current photovoltaic energy
generating installations of up to 1000Vdc.
TT WIRING 6mm2
CABLEADO TT 6mm2
CONNECTION
BORNA TERMINAL 35mm
CONEXIÓN 35mm
SEC. RECOMMENDED
SEC. RECOMENDADA
FROM 35 TO 16mm
DE 35 A 16mm22
PROTECTION BOX
STRING + ALTERNATE
CC WIRING 6mm2
AC WIRING 10 mm2
ELECTRIC VEHICLE
SPVE panels are specially designed to protect vehicle charging stations as specified in ITC-
BT-52.
These panels protect the vehicle charging station against short circuits, ground faults and
overvoltages.
The protection against permanent overvoltages complies with the POP 50:550 regulation,
protecting the installation against voltages greater than 275 V.
The protection against transient overvoltages will protect the loads against voltage peaks of
atmospheric origin, as well as the transients associated with the maneuvers carried out on
the electrical network.
Options: They can also be supplied with lock, Schuko base, differentials with automatic
reconnection, polycarbonate casing and energy meter.
LEGAL NOTICES
• Due to the policy of constant improvement of our products, Aiditec Systems, S.L. reserves the right to modify without prior notice
the products in this catalogue according to the evolution of the standards and techniques used at any time.
• The photos, drawings and technical descriptions in this catalogue are not contractual.
• Aiditec Systems, S.L. is not responsible for printing errors that may appear in this catalogue.
• Copying, electronic or other reproduction is only permitted under the authorization of Aiditec Systems, S.L.
October 2023. This catalog replaces the previous ones until further notice.