0% found this document useful (0 votes)
88 views

M580 and NTP Server

The document discusses configuring an M580 PLC as an NTP client by setting it to synchronize time with a Connexium Ethernet switch acting as an SNTP server. It provides steps for configuring the Connexium switch as an SNTP server and setting the M580 to use it as its NTP server.

Uploaded by

Alex Escalera
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
88 views

M580 and NTP Server

The document discusses configuring an M580 PLC as an NTP client by setting it to synchronize time with a Connexium Ethernet switch acting as an SNTP server. It provides steps for configuring the Connexium switch as an SNTP server and setting the M580 to use it as its NTP server.

Uploaded by

Alex Escalera
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Using the NTP client in the

M580 with the SNTP server in


the connexium switched
North Andover
March 2014
Overview
The purpose of this presentation is to configure NTP client in the M580, utilizing the
the SNTP server functionality of the Connexium switches .
IP:192.168.10.1
255.255.0.0
V1.02
IP:192.168.10.110
255.255.0.0
V 6.09

IP:192.168.10.100
255.255.0.0
Unity pro 8
Ethernet Switch
configurator

Schneider Electric - North Andover 2


Configuration of the connexium as NTP
server
The connexium Manages Switches must be set to have the Time synchronization
enabled. This is accomplished by using the Web interface to configure the switch

- Scan the network using the Ethernet Switch


configurator (2.2.5)
-- lunch the web page after adjusting the LAN
-- login to the switch with credentials admin/private

Schneider Electric - North Andover 3


Configuration of the connexium as NTP
server
- Set the IP address, in the basic
settings, choose network
- Click on Set and Reload after

- Highlight time
- Set time from PC if no external
server is available for
Synchronization , If you
have an external server set it's
IP address in the Time Source
field.
-Select set
- Select reload

Schneider Electric - North Andover 4


Configuration of the connexium as NTP
server

- Under Time, select SNTP


- set the configuration ON
- set and reload

Schneider Electric - North Andover 5


Configuration of the M580 as NTP client

- Under RIO DIO communicator


head, click on Channel 0 and click
on tab NTP
-- Select the M580 as NTP client
-- configure the NTP server IP
address (connexium)
-- build and transfer to the M580
-- lunch the embedded web page
192.168.10.1

Schneider Electric - North Andover 6


Configuration of the M580 as NTP client

service status

Schneider Electric - North Andover 7


The service is running properly
Configuration of the M580 as NTP
server

- Under the tab NTP,


choose NTP server
- the NTP server IP
address is the IP address A
of the M580 192.168.11.1

The Server initialized his time by synchronization of the


time with the CPU

Schneider Electric - North Andover 8


Configuration of the M580 as NTP
server