0% found this document useful (0 votes)
1K views

SMI List

This document provides a list of maintenance instructions from RDSO, including the instruction number, revision, description of the item covered, and a brief description. There are over 50 maintenance instructions listed that cover various aspects of overhead line equipment, insulators, auto tensioning devices, transformers, and other railway electrification systems.

Uploaded by

ctatrdsa
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views

SMI List

This document provides a list of maintenance instructions from RDSO, including the instruction number, revision, description of the item covered, and a brief description. There are over 50 maintenance instructions listed that cover various aspects of overhead line equipment, insulators, auto tensioning devices, transformers, and other railway electrification systems.

Uploaded by

ctatrdsa
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

List of RDSO’S Maintenance Instructions

(Updated on 13.12.2023)

SMI No. Rev. Instruction Regarding Description of the item

Failure of 25 kV pedestal insulator and to use


TI/MI/0001(10/82) 0 OHE, Insulators
o­nly solid core support insulator.

Use of disk insulator in place of 9-T solid core


TI/MI/0007(06/84) 0 9T Insulators
insulators of 25 kV ac OHE.

Failure of 9-t insulator due to non-provision


TI/MI/0008(09/84) 0 9T Insulators
of double eye distance rod at BWA location.

Load testing of 25kV Solid insulators before


TI/MI/0011(05/01) 1 Insulators
installation

TI/MI/0018 (04/06) 3 OHE, ATD Winch type regulating equipment.

Periodical maintenance instruction & trouble


TI/MI/0026 (07/03) 2 Capacitor Bank
shooting guidelines for capacitor bank.

Development of 107 mm2 silver bearing


TI/MI/0027 (03/98) 0 OHE, Conductor
copper contact wire (silver contents 0.1%).

Overhead equipment’s (OHE) o­n turn


TI/MI/0028 (09/01) 2 Panto entanglement
out/cross over to avoid panto entanglements.

3:1 Ratio, 3 Pulley type regulating


TI/MI/0029 (04/06) 3 ATD
equipment.

TI/MI/0034 (06/99) 0 Out -Of-Run (OOR) OHE. Contact wire in out of run OHE.

Provision of pipe o­n HEX Tie Rod of auto


TI/MI/0035 (09/01) 1 ATD
Tensioning Device (ATD).
Provision of insulated cadmium Copper
TI/MI/0036 (09/99) 0 Insulated Catenary catenary wire under over line structure o­n
25kV ac traction system.
TI/MI/0037 (10/02)
Maintenance instruction for OHE contact wire
Addendum and 2 Contact wire- OHE fittings
and associated fittings.
Corrigendum Slip (11/02)
TI/MI/0038 2 Traction Transformer Inspection test schedule for traction power
transformer.
(08/04)
(05/06)
Schedule of periodic overhauling of traction
TI/MI/0039(09/17) 2 Traction Transformer
transformer.

To measure the severity of pollution by brush


TI/MI/0040 (04/05) 0 Insulator
wash method.

Condition monitoring of lightning arresters


TI/MI/0041(04/10) 1 Lightning arrester
provided in 25kV system

Testing of 25 KV porcelain & composite


TI/MI/0042 (04/23) 1 Porcelain & Composite Insulators
insulators before installation.
TI/MI/0043
8 wheeler Instruction for 8-wheeler tower wagons
(08/08) 1
tower wagon covering instructions for DETC & DHTC.
(11/2017)
Guidelines for overhead hopper/chute/crane
TI/MI/0044 A (09/017) 2 Siding electrification loading/unloading of rakes in electrified
sidings.
Special Maintenance Instruction for 4-
4 wheeler
TI/MI/0044 B(11/12) 0 wheeler tower car. Superseded by
tower wagon
TI.MI/0052 (06/17)-Rev.0
Maintenance instructions for Gas Auto
TI/MI/0045 (11/09) 0 GAS ATD
tensioning device.
Guidelines for provision of insulated overlap
TI/MI/0046 0 Insulated Overlap in station limits of single line section (Not
Issued)
Precautions while splicing insulated catenary
TI/MI/0047 (09/12) 0 Insulated catenary
wire.
TI/MI/0048
(08/13) provision of disconnector assembly to the
1 lighting arresters
(07/21) lightning arresters
(03/23)
Tolerance and limits in 25kV AC OHE
Installation with 65/107 sq.mm
TI/MI/0049 (05/21) 1 OHE Tolerances
catenary/contact wire tension 1000 kgf/1000
kgf
TI/MI/0050 (09/17)
Prevention of bird menace on traction
1 Bird menace
(OHE&PSI)
TI/MI/0050 (09/21)
Installation of end clamp for catenary wire,
TI/MI/0051 (12/17) 0 End Clamp Installation
feeder wire and large span wire

Maintenance instructions for 4W Tower car


TI/MI/0052 (06/17) 0 Tower car
(TI/MI/0044 modified)
Pre & Post monsoon precautions for TRD
TI/MI/0053 (10/17) 0 Monsoon precautions
installations

Maintenance instructions on 25 kV Vacuum


TI/MI/0054 (09/17) 0 Vac.CB &BM
Circuit Breaker & Interrupter

Identification Of Defects On Traction


TI/MI/0055(10/17) 0 Thermal imager
Installation Using Thermo Vision Camera
TI/MI/0056
Maintenance Instruction for prevention of
(11/18) 2 Monkey menace
monkey menace
(11/20)
Maintenance instruction to prevent contact
TI/MI/0058 (08/21) 1 Contact Wire
wire parting at RRA locations

Prevention of bird faults and melting/flashing


TI/MI/0059 (01/20) 0 Prevention of bird faults
of catenary wire under suspension clamp

You might also like