This document provides product information for an AF52-40-00-13 100-250V50/60HZ-DC contactor. It lists technical specifications including rated operational current, voltage, power, breaking capacity, coil voltage, connecting capacity, and more. The contactor has 4 main poles and can be used for controlling non-inductive or slightly inductive loads up to 690V AC or 440V DC.

Uploaded by

servisergenset
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views4 pages

1SBL367201R1300 Af52 40 00 13 100 250v50 60hz DC Contactor

This document provides product information for an AF52-40-00-13 100-250V50/60HZ-DC contactor. It lists technical specifications including rated operational current, voltage, power, breaking capacity, coil voltage, connecting capacity, and more. The contactor has 4 main poles and can be used for controlling non-inductive or slightly inductive loads up to 690V AC or 440V DC.

Uploaded by

servisergenset
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

AF52-40-00-13

Products Low Voltage Products and Systems Control Products Contactors Block Contactors

General Information
Extended Product Type: AF52-40-00-13
Product ID: 1SBL367201R1300
EAN: 3471523133631
Catalog Description: AF52-40-00-13 100-250V50/60HZ-DC Contactor
Long Description: AF52 4-pole contactors are used for controlling power circuits up to 690 V AC and 440 V D
C. They are mainly used for controlling non-inductive or slightly inductive loads (i.e. resista
nce furnaces...). AF... contactors include an electronic coil interface accepting a wide contr
ol voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/
60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One c
oil can be used for different control voltages used worldwide without any coil change. AF co
ntactors have built-in surge protection and do not require additional surge suppressors. Th
e AF... series 4-pole contactors are of the block type design. - Main poles and auxiliary con
tact blocks: 4 N.O. main poles, front and side-mounted add-on auxiliary contact blocks (me
chanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror co
ntacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Acc
essories: a wide range of accessories is available.

Additional Information
ABB Industrial IT Suite: Control IT
ABS Certificate: ABS_15-GE1349500-PDA_90682247
Ambient Air Temperature: Close to Contactor for Storage -60...+80 °C
Near Contactor for Operation in Free Air -40 ... +70 °C
Block Contactor Type: 4-Pole Contactor
CB Certificate: CB_SE_77418
Climatic Withstand: Category B according to IEC 60947-1 Annex Q
Coil Voltage Code: 13
Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 4...35 mm²
Rigid 1/2x 6...35 mm²
Conventional Free-air Thermal Current acc. to IEC 60947-4-1, Open Contactors q = 40 °C 105 A
(Ith):
Country of Origin: France (FR)
Customs Tariff Number: 85364900
Declaration of Conformity - CE: 1SBD250001U1000
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
E-nummer: 3210311
EAN: 3471523133631
EPLAN Catalog Tree: Electrical engineering / Relays, contactors / Contactors
EPLAN Function Definition: Coil / Coil, 2 connection points / Coil for power contactor A1_A2
NO contact / NO contact, 2 connection points / Power NO contact 1_2
NO contact / NO contact, 2 connection points / Power NO contact 3_4
NO contact / NO contact, 2 connection points / Power NO contact 5_6
NO contact / NO contact, 2 connection points / Power NO contact 7_8
EPLAN Macro: 9AKK106930A0718
ETIM 4: EC000066 - Magnet contactor, AC-switching
ETIM 5: EC000066 - Magnet contactor, AC-switching
ETIM 6: EC000066 - Power contactor, AC switching
Full Load Amps Motor Use: (120 V AC) Single Phase 34 A
(240 V AC) Single Phase 50 A
(200 ... 208 V AC) Three Phase 48.3 A
(220 ... 240 V AC) Three Phase 54 A
(440 ... 480 V AC) Three Phase 52 A
(550 ... 600 V AC) Three Phase 52 A
General Use Rating UL/CSA: (600 V AC) 80 A
Horsepower Rating UL/CSA: (120 V AC) Single Phase 3 Hp
(240 V AC) Single Phase 10 Hp
(200 ... 208 V AC) Three Phase 15 Hp
(220 ... 240 V AC) Three Phase 20 Hp
(440 ... 480 V AC) Three Phase 40 Hp
(550 ... 600 V AC) Three Phase 50 Hp
IIT Publishing Status: Level 0 - Information enabled
Industrial IT Certification Level: 0
Instructions and Manuals: 1SBC101047M6801
Invoice Description: AF52-40-00-13 100-250V50/60HZ-DC Contactor
LR Certificate: LRS_1300087E1
Low Coil Consumption: No
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Maximum Electrical Switching Frequency: AC-1 600 cycles per hour
Maximum Mechanical Switching 3600 cycles per hour
Frequency:
Maximum Operating Altitude Permissible: 3000 m
Minimum Order Quantity: 1 piece
Mounted Auxiliary Contacts: 0 NO, 0 NC
Mounting Position: Max. add-on N.C. auxiliary contacts: see accessory fitting details for a 4-pole contactor AF40
... AF96
Mounting Positions: 1SBC500297F0000
Number of Auxiliary Contacts NC: 0
Number of Auxiliary Contacts NO: 0
Number of Main Contacts NC: 0
Number of Main Contacts NO: 4
Object Classification Code: Q
Order Multiple: 1 piece
Package Level 1 EAN: 3471523133631
Package Level 1 Gross Weight: 1.27 kg
Package Level 1 Height: 103 mm
Package Level 1 Length: 150 mm
Package Level 1 Units: 1 piece
Package Level 1 Width: 150 mm
Package Level 2 Height: 300 mm
Package Level 2 Length: 300 mm
Package Level 2 Units: 8 piece
Package Level 2 Width: 250 mm
Package Level 3 Units: 192 piece
Packing Type: Box
Power Loss: at Rated Operating Conditions AC-1 per Pole 6.3 W
at Rated Operating Conditions AC-3 per Pole 1.7 W
Product Main Type: AF52
Product Name: Block Contactor
Product Net Depth: 113.5 mm
Product Net Height: 125.5 mm
Product Net Weight: 1.16 kg
Product Net Width: 70 mm
Product Packing Type: Box
RMRS Certificate: RMRS_1400682124
Rated Control Circuit Voltage (Uc): 50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Rated Frequency (f): Main Circuit 50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp): 6 kV
Rated Insulation Voltage (U):
i acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Operational Current AC-1 (Ie): (690 V) 40 °C 100 A
(690 V) 60 °C 80 A
(690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 60 °C 53 A
(380 / 400 V) 60 °C 53 A
(415 V) 60 °C 53 A
(440 V) 60 °C 53 A
(500 V) 60 °C 45 A
(690 V) 60 °C 35 A
Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 15 kW
(380 / 400 V) 22 kW
(415 V) 30 kW
(440 V) 30 kW
(500 V) 30 kW
(690 V) 30 kW
Rated Operational Voltage: Main Circuit 690 V
Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Resistance to Vibrations acc. to IEC 5 ... 300 Hz 3 g Closed position / 2 g Open position
60068-2-6:
Selling Unit of Measure: piece
Short Description: AF52-40-00-13 100-250V50/60HZ-DC Contactor
Terminal Type: Screw Terminals
UL Certificate: UL_20141124-E312527-14-2
UL Listing Card: UL_E312527
UNSPSC: 39121529
Wire Stripping Length: Main Circuit 16 mm