12-1079

TRUE
FRONT
ACCESS
HIGH RATE MAX
UPS 12-355MRF
Valve Regulated Lead Acid (VRLA) Battery Series
Designed for UPS Standby Power Applications

FEATURES & BENEFITS


APPLICATIONS • True Front Access threaded • Optional True Front Access gas
copper alloy inserts for reduced collection system
• Data Centers maintenance and increased safety
• Multicell design for ease of
• Network Operations Centers • Terminal versatility - ease of installation and maintenance
• Industrial Process Control diagnostic readings with C&D • UL-recognized component
Ohmic Ring®
Facilities • Compliant to major global
• Innovative front terminal design specifications
• Internet Housing Sites maximizing energy density with
direct connect extrusion fusion • UL1778, 924, 1989
• Semiconductor Manufacturing • BS 6290-4
weld technology
• Banks & Financial Markets • IEC 896-2
• Reduced headspace driving • UL94 V-0
• Power Generation Plants higher energy density, in cabinet
• Hospitals & Testing or rack applications • Not restricted for air transport -
Complies with IATA/ICAO
Laboratories • Removable handles for ease of Special Provision A67
installation
• Emergency 911 Response
• Thermally welded case-to-cover • Not restricted for surface transport -
Centers classified as non-hazardous
bond to ensure a leak-proof seal
material as related to DOT-CFR
• Flame-retardant polypropylene Title 49 parts 171-189
case and cover compliant with
UL94 V-0 with an Oxygen • Not restricted for water transport -
Limiting Index of greater than 28 classified as non-hazardous
material per Amendment 27
• Absorbent Glass Mat (AGM)
technology for efficient gas • 3 Year Full Warranty (refer to
recombination of over 99% Dynasty warranty card, 41-9027)

SPECIFICATIONS
Constant Power Discharge Ratings - Watts per cell @ 77ºF (25ºC)
Operating Time (in minutes) to 1.67 volts per cell
20 Hour Rate @
Model Number Voltage Per Unit 5 10 15 20 30 40 50 60 90
77ºF (25ºC) to 1.75
UPS12-355MRF 12 V 108 Ah 591.3 440.8 358.4 299.7 229.4 190.5 164.9 146.6 105.6

*Nominal 20 hr rate to 1.75 VPC in Ampere-Hours

12-1079/0611/CD www.cdtechno.com
SPECIFICATIONS

Cells Battery Weight Maximum Terminal Ohms


Model per Discharge Current Impedance 60
Unit lbs kg Rating (AMPS) Hz (Ω)
UPS12-355MRF 6 80 36 800 0.0030

DIMENSIONS

A B C D E F G H
MODEL in mm in mm in mm in mm in mm in mm in mm in mm
UPS12-355MRF 18.5 469 19.5 496 20.1 511 18.5 470 8.5 216 9.3 235 4.3 110 4.2 107
* All dimensions in inches and (millimeters). All dimensions are for reference only. Contact a C&D Representative for complete dimensional information.

Operating Temperature Range Discharge: -40°F (-40°C) to +160°F (71°C)


with temperature compensation Charge: -10°F (-23°C) to +140°F (60°C)
Nominal Operating Temperature Range +68°F (20°C) to +80°F (27°C)

Recommended Maximum Charging C/5 amperes @ 20 Hr rate


Current Limit

Float Charging Voltage 13.5 to 13.8 VDC average per 12V unit

Maximum AC Ripple (Charger) 0.5% RMS or 1.5% P-P of float charge voltage recommended for best results.
Max voltage allowed = 1.4% RMS (4% P-P) Max current allowed = C/20

Self Discharge Battery can be stored up to 6 months at 77°F (25°C) before a freshening
charge is required. Batteries stored at temperatures greater than 77°F
(25°C) will require recharge sooner than batteries stored at lower
temperatures. See C&D brochure 41-7272, Self-Discharge and Inventory
Control for details.

Equalize charge and cycle 14.40 to 14.80 VDC average per 12V unit @ 77°F (25°C)
service voltage

Terminal: Inserted - Inter-unit Threaded copper alloy insert terminal to accept M6 bolt
connector provided

Terminal Hardware 110 in.-lbs. (12.4 N-m)


Initial Torque:

UPS 12-355MRF
Constant Power Discharge Ratings - Watts Per Cell @ 77°F (25°C)
Operating Time to End Point Voltage (in minutes)
End Point
5 10 15 20 30 40 45 50 60 90
Volts/Cell
1.75 543.9 411.8 334.9 283.3 220.6 183.8 170.6 159.6 142.2 103.1
1.70 578.3 431.1 350.5 294.0 226.0 188.0 174.4 163.0 145.1 104.7
1.67 591.3 440.8 358.4 299.7 229.4 190.5 176.6 164.9 146.6 105.6
1.65 600.6 447.7 364.0 303.7 231.7 192.5 178.5 166.8 148.3 106.5
Note: Specifications subject to change without notification. Above ratings do not include interunit connector voltage drops

Any data, descriptions or specifications presented herein are subject to revision by C&D Technologies, Inc.
without notice. While such information is believed to be accurate as indicated herein, C&D Technologies, Inc. makes
no warranty and hereby disclaims all warranties, express or implied, with regard to the accuracy or completeness of
such information. Further, because the product(s) featured herein may be used under conditions beyond its control,
1400 Union Meeting Road C&D Technologies, Inc. hereby disclaims all warranties, either express or implied, concerning the fitness or suitability
P.O. Box 3053 • Blue Bell, PA 19422-0858 of such product(s) for any particular use or in any specific application or arising from any course of dealing or usage
(215) 619-2700 • Fax (215) 619-7899 • (800) 543-8630 of trade. The user is solely responsible for determining the suitability of the product(s) featured herein for user’s
[email protected] intended purpose and in user’s specific application.
www.cdtechno.com Copyright 2011 C&D TECHNOLOGIES, INC. Printed in U.S.A. 12-1079 0611/CD