0% found this document useful (0 votes)
42 views

Conventional Heat Detector C9020T

The document describes a conventional heat detector with features like an upper and lower cover for easy installation and maintenance, temperature monitoring via an MCU, and non-polarity two-wire connection. It provides operating details like voltage, current, indicators, temperature range, and specifications.

Uploaded by

许浩江
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
42 views

Conventional Heat Detector C9020T

The document describes a conventional heat detector with features like an upper and lower cover for easy installation and maintenance, temperature monitoring via an MCU, and non-polarity two-wire connection. It provides operating details like voltage, current, indicators, temperature range, and specifications.

Uploaded by

许浩江
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

CONVENTIONAL HEAT DETECTOR

C����T

Features
Designed with an upper cover and a lower cover, it can
be installed, debugged and maintained conveniently.
Within a MCU, it can monitor temperature of the site in
real time.
Non-polarity, two-bus connection that ensures conve-
nient installation and maintenance.
The detector is non-addressable.

Description

C����T point-type Conventional Rate of Rise and Fixed Temperature Heat Detector (De-
tector hereunder) is a two-wire switch-type temperature-sensing detector. As a non-po-
lar two-cables connection is adopted in the detector, it is compatible in conventional fire
alarm control systems. The detector can be connected with addressable fire alarm con
trol systems via the zone module.
PRODUCT DATESHEET-C����T

The detector is applicable in places where fire might generate volume heat. e.g. in indus-
trial and civil buildings such as in the kitchen, boiler room, generator room, drying plant,
and smoking room.

Executivestandard EN��-�
Operating Voltage DC��V(allowance:DC��V~��V)
Workingcurrent Standby current:<��uA @DC��V
Alarm current:�mA~��mA @DC��V
Wiringmethod non-polar,twocables
Indicators During monitoring, the red indicator blinks once per �
seconds.In sensor failure alarm, the red indicator
blinks twice per � seconds.In fire alarm mode, the red
indicator remains on.
-��℃~+��℃
OperatingTemperature Relative humidity: ≤��% (��℃±�℃, without conden-
CONVENTIONAL
Executivestandard HEAT DETECTOR
EN��-�
C����T
Operating Voltage DC��V(allowance:DC��V~��V)
Workingcurrent Standby current:<��uA @DC��V
Alarm current:�mA~��mA @DC��V
Wiringmethod non-polar,twocables
Indicators During monitoring, the red indicator blinks once per �
seconds.In sensor failure alarm, the red indicator
blinks twice per � seconds.In fire alarm mode, the red
indicator remains on.
OperatingTemperature -��℃~+��℃
Relative humidity: ≤��% (��℃±�℃, without conden-
sation)
Weight About ��g without base;about ���g with base DZ-���K
Type of the Base DZ-���K
FixedTemperature ��℃@A�S
IngressProtection Rating IP��
PRODUCT DATESHEET-C����T