9000A Sensor General Purpose
9000A Sensor General Purpose
General Purpose
DYNAMIC
Sensitivity, ±5%, 25°C ______________________________ 100 mV/g
Acceleration Range 1 _________________________________ 50 g peak
Amplitude Nonlinearity ______________________________ 1%
Frequency Response
±5% __________________________________________1.2 - 5,000 Hz
±10% ________________________________________ 0.9 - 8,000 Hz
±3 dB ________________________________________ 0.4 - 10,000 Hz
Resonance Frequency ________________________________ 28 kHz
Transverse Sensitivity, max. _________________________ 5% of axial
Temperature Response ______________________________see graph
ELECTRICAL
Power Requirement
voltage source ______________________________18 - 28 VDC
current regulating diode 1,2 __________________ 2 - 20 mA
Electrical Noise, equiv. g, nominal
Broadband 1 Hz to 10 kHz ___________ 300 µg
Spectral 10 Hz _____________________ 8 µg/√Hz
100 Hz ___________________ 3 µg/√Hz
1,000 Hz _________________ 2.5 µg/√Hz
Output Impedance, max. _____________________________ 150 Ohms
Bias Output Voltage, nominal _______________________ 8 - 12 VDC
Grounding ____________________________________________ case isolated, internally shielded
ENVIRONMENTAL
Temperature Range __________________________________ -54 to 121°C
Shock Limit __________________________________________ 5,000 g peak
PHYSICAL
Weight ______________________________________________ 48.6 gm
Case Material ________________________________________ stainless steel
Mounting _____________________________________________ 1/4 - 28 tapped hole
Output Connector ____________________________________MIL-C-5015, 2 pin
Pin A _________________________________________ signal, power
Pin B _________________________________________ common
T Y P I C A L T E M P E R AT U R E R E S P O N S E
Temperature
NOTES:
1 To minimize the possibility of signal distortion when driving long cables with high vibration signals, 24 to 30 VDC
powering is recommended. The higher level constant current source should be used when driving long cables
(Please consult Entek Customer Service).
2 A maximum current of 6 mA is recommended for operating temperatures in excess of 100 °C.
Ordering Information
Model Description P/N
9000A General purpose accelerometer - 100 mV/g, 0.4-10,000 Hz (3 dB), top exit, 43781I
Mil Spec connector.
www.rockwellautomation.com
Headquarters for Allen-Bradley Products, Rockwell Software Products and Global Manufacturing Solutions
Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414.382.2000, Fax: (1) 414.382.4444
Europe/Middle East/Africa: Rockwell Automation SA/NV, Vorstlaan/Boulevard du Souverain 36, 1170 Brussels, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640
Asia Pacific: Rockwell Automation, 27/F Citicorp Centre, 18 Whitfield Road, Causeway Bay, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846
Corporate Headquarters
Rockwell Automation, 777 East Wisconsin Avenue, Suite 1400, Milwaukee, WI, 53202-5302 USA, Tel: (1) 414.212.5200, Fax: (1) 414.212.5201
Publication ENACC-TD901C-EN-P February 2003 Copyright © 2003 Rockwell Automation. All rights reserved
ICP is a registered trademark of PCB Group, Inc..