0% found this document useful (0 votes)
25 views1 page

IP Vs NEMA FGD

The document compares the NEMA and IP ratings systems for electrical enclosures. It provides a chart that lists the NEMA ratings along with their equivalent IP ratings and definitions. Higher ratings indicate increasing levels of protection against solids, water, dust and immersion.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
25 views1 page

IP Vs NEMA FGD

The document compares the NEMA and IP ratings systems for electrical enclosures. It provides a chart that lists the NEMA ratings along with their equivalent IP ratings and definitions. Higher ratings indicate increasing levels of protection against solids, water, dust and immersion.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

IP vs NEMA

NEMA Ratings and IP Equivalency Chart

NEMA Rating IP Equivalent NEMA Definition IP Definition


Enclosures constructed for indoor use 1 = Protected against solid foreign
1 IP10 to provide a degree of protection to objects of 50mm in diameter and 0 = Not Protected
personnel against incidental contact greater
Enclosures constructed for indoor 1 = Protected against solid foreign
1 = Protected against vertically
2 IP11 used to provide a degree of protection objects of 50mm in diameter and
falling water drops
to personnel against incidental contact greater
Enclosures constructed for either
4 = Protected against water sprayed
indoor or outdoor used to provide a 5 = Protected against dust ‐ Limited
3 IP54 from all directions ‐ Limited to
degree of protection to personnel to ingress (no harmful deposit)
ingress permitted.
against incidental contact with the
Enclosures constructed for either
4 = Protected against water sprayed
indoor or outdoor used to provide a 1 = Protected against vertically
3R IP14 from all directions ‐ Limited to
degree of protection to personnel falling water drops
ingress permitted.
against incidental contact with the
Enclosures constructed for either
4 = Protected against water sprayed
indoor or outdoor use to provide a 5 = Protected against dust ‐ Limited
3S IP54 from all directions ‐ Limited to
degree of protection to personnel to ingress (no harmful deposit)
ingress permitted.
against incidental contact with the
Enclosures constructed for either
6 = Protected against strong jets of
indoor or outdoor use to provide a 5 = Protected against dust ‐ Limited
4 IP 56 water from all directions ‐ Limited
degree of protection to personnel to ingress (no harmful deposit)
to ingress permitted.
against incidental contact with the
Enclosures constructed for either
indoor or outdoor use to provide a 6 = Protected against strong jets of
5 = Protected against dust ‐ Limited
4X IP56 degree of protection to personnel water from all directions ‐ Limited
to ingress (no harmful deposit)
against incidental contact with the to ingress permitted.
enclosed equipment; to provide a
Enclosures constructed for indoor use
to provide a degree of protection to 5 = Protected against dust ‐ Limited 2 = Protected against direct sprays
5 IP52
personnel against incidental contact to ingress (no harmful deposit) of water up to 15° from the vertical.
with the enclosed equipment; to
Enclosures constructed for either
7 = Protected against the effects of
indoor or outdoor use to provide a
temporary immersion between
6 IP67 degree of protection to personnel 6 = Totally protected against dust
15cm and 1m. Duration of test 30
against incidental contact with the
minutes.
enclosed equipment; to provide a

As of April 2010

You might also like