The document compares the NEMA and IP ratings systems for electrical enclosures. It provides a chart that lists the NEMA ratings along with their equivalent IP ratings and definitions. Higher ratings indicate increasing levels of protection against solids, water, dust and immersion.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
25 views1 page
IP Vs NEMA FGD
The document compares the NEMA and IP ratings systems for electrical enclosures. It provides a chart that lists the NEMA ratings along with their equivalent IP ratings and definitions. Higher ratings indicate increasing levels of protection against solids, water, dust and immersion.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1
IP vs NEMA
NEMA Ratings and IP Equivalency Chart
NEMA Rating IP Equivalent NEMA Definition IP Definition
Enclosures constructed for indoor use 1 = Protected against solid foreign 1 IP10 to provide a degree of protection to objects of 50mm in diameter and 0 = Not Protected personnel against incidental contact greater Enclosures constructed for indoor 1 = Protected against solid foreign 1 = Protected against vertically 2 IP11 used to provide a degree of protection objects of 50mm in diameter and falling water drops to personnel against incidental contact greater Enclosures constructed for either 4 = Protected against water sprayed indoor or outdoor used to provide a 5 = Protected against dust ‐ Limited 3 IP54 from all directions ‐ Limited to degree of protection to personnel to ingress (no harmful deposit) ingress permitted. against incidental contact with the Enclosures constructed for either 4 = Protected against water sprayed indoor or outdoor used to provide a 1 = Protected against vertically 3R IP14 from all directions ‐ Limited to degree of protection to personnel falling water drops ingress permitted. against incidental contact with the Enclosures constructed for either 4 = Protected against water sprayed indoor or outdoor use to provide a 5 = Protected against dust ‐ Limited 3S IP54 from all directions ‐ Limited to degree of protection to personnel to ingress (no harmful deposit) ingress permitted. against incidental contact with the Enclosures constructed for either 6 = Protected against strong jets of indoor or outdoor use to provide a 5 = Protected against dust ‐ Limited 4 IP 56 water from all directions ‐ Limited degree of protection to personnel to ingress (no harmful deposit) to ingress permitted. against incidental contact with the Enclosures constructed for either indoor or outdoor use to provide a 6 = Protected against strong jets of 5 = Protected against dust ‐ Limited 4X IP56 degree of protection to personnel water from all directions ‐ Limited to ingress (no harmful deposit) against incidental contact with the to ingress permitted. enclosed equipment; to provide a Enclosures constructed for indoor use to provide a degree of protection to 5 = Protected against dust ‐ Limited 2 = Protected against direct sprays 5 IP52 personnel against incidental contact to ingress (no harmful deposit) of water up to 15° from the vertical. with the enclosed equipment; to Enclosures constructed for either 7 = Protected against the effects of indoor or outdoor use to provide a temporary immersion between 6 IP67 degree of protection to personnel 6 = Totally protected against dust 15cm and 1m. Duration of test 30 against incidental contact with the minutes. enclosed equipment; to provide a