0% found this document useful (0 votes)
23 views

Assignment 1 Solution

The document provides specifications for dead and live loads on the ground floor and roof of a building, including load values for structural elements and occupancy types. It also lists the load combinations used for structural design calculations.

Uploaded by

kowe petit
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views

Assignment 1 Solution

The document provides specifications for dead and live loads on the ground floor and roof of a building, including load values for structural elements and occupancy types. It also lists the load combinations used for structural design calculations.

Uploaded by

kowe petit
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

CIV312 Fall 2014

Assignment 1, Design Task 1)


Solution
Fei Tong, Sept. 15, 2014

Ground Floor Roof


Dead Loads
Specification Loads Specification Loads
Composite slab 125mm (overall thickness) 100mm (overall thickness)
steel deck 38mm deck 2.55 kPa 38mm deck 1.95 kPa
concrete cover 90mm thick, normal density 65mm thick, normal density
Steel framing 0.6 kPa 0.6 kPa 0.6 kPa 0.6 kPa
MEP* Services
0.25 kPa 0.25 kPa
ducts/pipes/wiring Typical Typical
Suspended ceilings 0.2 kPa 0.2 kPa 0.2 kPa 0.2 kPa
Finishing Carpeting 0.10 kPa n.a. n.a.
Fireproof Sprayed fire protection 0.07 kPa Sprayed fire protection 0.07 kPa
Partitions 1.0 kPa 1.0 kPa n.a. n.a.
Roofing n.a. n.a. 3 ply asphalt and gravel 0.27 kPa
glass fibre, rigid
Insulation n.a. n.a. 0.07 kPa
100mm thick
Total Specified Dead Load 4.77 kPa 3.41 kPa

Live Loads Ground Floor Roof


Occupancy 1: Stacks 7.2 kPa
Occupancy 2: Computers, Info 4.8 kPa
n.a.
Occupancy 3: Bathrooms 2.4 kPa
Occupancy 4: MEP rooms 3.6 kPa
Roof (not accessible to either
n.a. 1.0 kPa
pedestrain or vehicular traffic)
The Specified Live Load
7.2 kPa 1.0 kPa
chosen for design
CIV312 Fall 2014
Assignment 1, Design Task 5)
Solution
Fei Tong, Sept. 17, 2014

Specified Loads Ground Floor Roof


Dead 4.77 kPa 3.41 kPa
Live 7.2 kPa 1.0 kPa
Snow n.a. 1.29 kPa
Wind n.a. -0.837 kPa

Load Combinations Ground Floor Roof


1.4D (1.4)(4.77) = 6.68 kPa (1.4)(3.41) = 4.77 kPa
1.25D+1.5L+0.5S or 0.4W (1.25)(4.77)+(1.5)(7.2) = 16.8 kPa not governing
1.25D+1.5S+0.5L or 0.4W not governing (1.25)(3.41)+(1.5)(1.29) = 6.20 kPa
0.9D+1.4W not governing (0.9)(3.41)+(1.4)(-0.837) = 1.90 kPa
Factored Loads 16.8 kPa 6.20 kPa