Fecmcbp40r00en
Fecmcbp40r00en
NEW INSTALLATION
RESIDENTIAL
LIFTS
DOC-FECMCBP40R00EN-2.7
PRINTABLE VERSION: 30-01-2017 www.fermator.com
ENG
Door configuration
LIFT APPLICATION
Door cycles per year: Up to 800.000.
Traffic peak of the door: Up to 240 cycles per hour.
Traffic lift speed: Up to 2,5 m/s.
APPLICATION RANGE
Opening Panel Clear opening - PL (mm) Clear height - HL (mm)
Steel 600 - 1.400 2.000 - 2.400
C2
Glass 600 - 1.000 2.000 - 2.100
Steel 600 - 2.400 2.000 - 2.400
C4
Glass 600 - 1.000 2.000 - 2.100
Steel 700 - 1.400 2.000 - 2.400
T2 RLO
Glass 700 - 1.000 2.000 - 2.100
Steel 600 - 1.400 2.000 - 2.400
T2 - T3 - T4
Glass 600 - 1.000 2.000 - 2.100
PANELS
Steel panels Glass panels
Metal Double Fritted Wien type Bevel big Flush big Full glass Full Aluminium
Vision glass in
sheet (1) skin vision vision vision vision in skirting moorings glass
Opening
W
NO F.R
F.R.E30 (2)
F.R.E120 (2) NO F.R NO F.R
F.R.EI30 (2) F.R E120 F.R.E60 F.R.E60
C2 - C4 - T2 - T3 - T4 F.R.EI60 (2) DIN18091
NO F.R NO F.R (3)
F.R.E120 F.R.E120
NO F.R
F.R.EI120 (2) F.R.EI30 F.R.EI30
F.R.EW30 (2)
F.R.EW60 (2)
1 Solid execution option.
2 Execution with smoke seal protection available.
3 Only available with 75 mm sill.
F.R.: Fire rated according to EN 81-58.
FRAMES DEFINITION
Frame type Options
Frame depth - FD Jamb M1 Header - HD Jamb M2
cealed
MSS
STD
con-
40/10 www.fermator.com 2
Door configuration
FRAMES DETAIL
Frame type STD MSS MV MSS MH Concealed
Frame detail
MSS MV: Frame without sill supplement with visible sill support.
MSS MH: Frame without sill supplement with concealed sill support.
SILLS
Reinforced
Type of sill Aluminium Steel Steel concealed Massive
aluminium
Profile detail
Availability
Heated sill option (1)
Dust holes
1 Not available for C2.
SILL SUPPLEMENTS
Type of supplement Aluminium Reinforced aluminium Steel Massive
Profile detail
Availability
STANDARDS
EN 81-21 EN 81-41 EN 81-71 EN 81-72
EN 81-1/2 EN 81-20/50
Opening Existing buildings Impaired Vandal resistance lifts Firefighters
Safety rules Safety rules
FD: 20 - 25 FD: 40 - 60 mobility Cat. I Cat. II lifts
C2 - C4 - T2 - T3 - T4
3 www.fermator.com 40/10
Door configuration
PROTECTION
IP21 IPX3 IP54 IP65 EEx
Protection against a solid Protected against sprays Protection against dust and protected against water Sealed against dust and Explosion proof, Group II
foreign body of 12,5 mm of water up to 60 degrees splashed from all directions. protected against jets of (surface industries) and
Opening or more in diameter and from the vertical. water from all directions. Category 2 (explosive
protected against vertically atmosphere between 10
falling drops of water. Magnetic contact Mechanical contact and 1.000 hrs/yr).
C2 - C4 - T2 - T3 - T4
Type of panel
Basic
regulation support
EN 81-1/2 EN 81-20/50
COMPATIBILITY
100 162,5 39 110
HL + 532
84
HL + 338
MOTOR
MOTOR
HL + 395
AFO: HL + 220 90 60
400
90 60
250
500
210
AFO: HL + 220
10
HL
210
HL
49,5 90 30 90 90 30 90
±0 ±0
H
40/10 www.fermator.com 4
Door configuration
82 140 110
HL + 500
84
HL + 338
MOTOR
HL + 285
MOTOR
AFO: HL + 220 90 60
90 60
AFO: HL + 220
400
250
500
210
560
210
10
HL HL
90 30 90
±0
30 90 30 90
±0
H
H
82 140
HL + 485 110
MOTOR
HL + 345
90
HL + 345
MOTOR
90 60 AFO: HL + 220 90 60
AFO: HL + 220
400
500
260
210
560
210
HL HL
90 30 90
±0
30 90 30 90
±0
H
H
5 www.fermator.com 40/10
Technical features
T2 mechanism
GENERAL FEATURES
Noise level < 53 dB.
Total weight Reference: T2 PL 600 mm HL 2.400 mm 120 x 60 mm frame, with sheet metal panels - 74 kg.
Safety closing system With spring, except T1 with counterweight.
INSTALLATION
Pre-adjusted and tested to simplify the installation.
Optional 20 mm between sills (Ask the commercial department for more information).
DOOR HOISTWAY PROJECTION (DHP) - FIXING BRACKETS: HEADER 210 mm WITH 120x25 mm FRAME
C2 C4 C6 C8 T1 T2 T3 T4
DHP Bracket Bracket Bracket Bracket Bracket Bracket Bracket
DHP* DHP* DHP* DHP* DHP* DHP* DHP* DHP* Bracket
type
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
1 0 - 65 W - - - - - - - - - - 0 - 65 W - - - -
2a - - - - - - - - - - - - - - - - - -
2b - - - - - - - - - - - - - - - - - -
3 66 - 100 D - - - - - - - - - - 66 - 100 D - - - -
A D V2 V7 V8 X W
Bracket
type
Thickness 5 5 4 4 4 5 5
(mm)
*See DHP dimension in sill detail (technical drawings pages).
40/10 www.fermator.com 6
Technical drawing
2 panel centre parting door
54 mm sill
2PL + 100 20 54 FD
= PL = MECHANICAL
U DETAILS
S
Concentric
Ø 48
Eccentric
Ø 33
HL + 210
HL + 152
HL + 10
HL
thickness
PL ≤ 700 = 3
PL ≥ 750 = 2,5
SILL
DETAIL
30
H
= =
= PL - 200 = DHP(1) FD + 54
2PL + 40 54 FD
49 5
5
30
42
2PL + 100
L
H
160 PL + 50
54
DHP(1)
M1 PL M2
FD
Notes:
DHP
1 See DHP details in technical features page.
Upper bracket
- If not otherwise indicated all dimensions in mm.
Lower bracket
7 www.fermator.com 40/10
Technical drawing
4 panel centre parting door
75 mm sill
G 1,5PL + 100 20 75 FD
= PL =
S U
MECHANICAL
DETAILS
HD
Concentric
Ø 48
Eccentric
Ø 33
HL + 210
HL + 152
HL + 10
HL
thickness
3
SILL
DETAIL
FD + 75
30
L
H
75 FD
= = 5
= PL - 200 = DHP(1) 32,5 32,5 5
1,5PL + 40
5
30
42
1,5PL + 100
B 0,75PL + 50
H
L
75
DHP(1)
M1 PL M2
FD
Notes:
DHP
1 See DHP details in technical features page.
Upper bracket
B For PL < 950 = 100. For PL ≥ 950 = 160.
- If not otherwise indicated all dimensions in mm.
Lower bracket
40/10 www.fermator.com 8
Technical drawing
4 panel centre parting door
90 mm sill
Single locking device (PL 600 - 1.150)
G 1,5PL + 100 20 90 FD
= PL =
S U
MECHANICAL
DETAILS
HD
Concentric
Ø 48
Eccentric
Ø 33
HL + 210
HL + 152
HL + 10
HL
thickness
3
SILL
DETAIL
FD + 90
30
L
H
90 FD
5
= =
40 40 5
= PL - 200 = DHP(1)
1,5PL + 40
5
30
42
1,5PL + 100
B 0,75 PL + 50
L
H
90
DHP(1)
M1 PL M2
FD
Notes:
DHP
1 See DHP details in technical features page.
Upper bracket
B For PL < 950 = 100. For PL ≥ 950 = 160.
- If not otherwise indicated all dimensions in mm.
Lower bracket
9 www.fermator.com 40/10
Technical drawing
4 panel centre parting door
90 mm sill
Double locking device (PL 1.200 - 2.400)
1,5PL + 100 20 90 FD
= PL =
S S U
MECHANICAL
DETAILS
HD
Concentric
Ø 48
Eccentric
Ø 33
HL + 210
HL + 152
HL + 10
HL
thickness
PL ≤ 1.400 = 3
PL > 1.400 = 2,5
SILL
30
L
H
DETAIL
= = =
= DHP(1) FD + 90
PL - 200 =
1,5PL + 40 90 FD
5
40 40 5
5
30
42
1,5PL + 100
= 160 160 =
L
H
90
M1 PL M2 DHP(1)
FD
Notes:
DHP
1 See DHP details in technical features page.
Upper bracket
- If not otherwise indicated all dimensions in mm.
Lower bracket
40/10 www.fermator.com 10
Technical drawing
2 panel side opening door
75 mm sill - RLO
1,5PL + 50 M2 - 55 20 75 FD
PL M2
U MECHANICAL
S
DETAILS
HD
Concentric
Ø 48
Eccentric
Ø 33
HL + 210
HL + 152
HL + 10
HL
thickness
PL 700 = 3
PL ≥ 750 = 2,5
SILL
30
DETAIL
H
L
= =
0,5PL + 120 PL - 200 M2 + 100 DHP(1)
FD + 75
75 FD
5
5
32,5 32,5
5
30
42
25 1,5PL + 40 M2 - 20
160
75
15
FD
M1 PL M2 DHP(1)
Notes:
DHP
1 See DHP details in technical features page.
Upper bracket
- If not otherwise indicated all dimensions in mm.
Lower bracket
11 www.fermator.com 40/10
Technical drawing
2 panel side opening door
90 mm sill
1,5PL + 100 M2 - 55 20 90 FD
PL M2
U MECHANICAL
S
DETAILS
HD
Concentric
Ø 48
Eccentric
Ø 33
HL + 210
HL + 152
HL + 10
HL
thickness
PL ≤ 700 = 3
PL ≥ 750 = 2,5
SILL
30
DETAIL
H
= =
0,5PL + 120 PL - 200 M2 + 100 DHP(1)
FD + 90
90 FD
5
5
40 40
5
30
42
25 1,5PL + 40 M2 - 20
160
90
15
FD
M1 PL M2 DHP(1)
Notes:
DHP
1 See DHP details in technical features page.
Upper bracket
- If not otherwise indicated all dimensions in mm.
Lower bracket
40/10 www.fermator.com 12
Technical drawing
2 panel side opening door
90 mm sill - RLO
1,5PL + 50 M2 - 55 20 90 FD
PL M2
U
S
MECHANICAL
DETAILS
HD
Concentric
Ø 48
Eccentric
Ø 33
HL + 210
HL + 152
HL + 10
HL
thickness
PL 700 = 3
PL ≥ 750 = 2,5
SILL
30
H
L
DETAIL
= =
0,5PL + 120 PL - 200 M2 + 100 DHP(1)
FD + 90
90 FD
5
5
40 40
5
30
42
25 1,5PL + 40 M2 - 20
160
90
15
FD
M1 PL M2 DHP(1)
Notes:
DHP
1 See DHP details in technical features page.
Upper bracket
- If not otherwise indicated all dimensions in mm.
Lower bracket
13 www.fermator.com 40/10
Technical drawing
3 panel side opening door
135 mm sill
C M2 - 55 20 135 FD
PL M2
U
S
MECHANICAL
DETAILS
HD
Concentric
Ø 48
Eccentric
Ø 33
HL + 210
HL + 152
HL + 10
HL
thickness
PL ≤ 1.050 = 3
PL ≥ 1.100 = 2,5
SILL
30
H
L
DETAIL
= =
0,35 PL + 120 PL - 200 M2 + 100 DHP(1)
FD + 135
135 FD
5
5
40 40 40 5
5
30
42
K 1,35 PL + 40 M2 - 20
160
H
L
135
15
FD
M1 PL M2 DHP(1)
PL 600 650 700 750 800 850 900 1.000 1.100 1.200 1.300 1.400
C 895 962 1.030 1.095 1.160 1.227 1.295 1.430 1.560 1.695 1.830 1.960
K 10 9.5 10 7.5 5 4.5 5 5 0 0 0 -5
Notes:
DHP
1 See DHP details in technical features page.
Upper bracket
- If not otherwise indicated all dimensions in mm.
Lower bracket
40/10 www.fermator.com 14
Technical drawing
4 panel side opening door
180 mm sill
C M2 - 55 20 180 FD
PL M2
U
S MECHANICAL
DETAILS
HD
Concentric
Ø 48
Eccentric
Ø 33
HL + 210
HL + 152
HL + 10
HL
thickness
PL ≤ 1.400 = 3
PL ≥ 1.450 = 2,5
SILL
30
H
L DETAIL
= =
0,25PL + 120 PL - 200 M2 + 100 DHP(1) FD + 180
180 FD
5
5 5
40 40 40 40 5
K 1,25PL + 40 M2 - 20
5
B
30
42
L
180
15
FD
M1 PL M2 DHP(1)
PL 600 650 700 750 800 850 900 1.000 1.100 1.200 1.300 1.400
C 875 925 975 1.039 1.100 1.164 1.225 1.350 1.475 1.600 1.725 1.850
K 50 37,5 25 26,5 25 26.5 25 25 25 25 25 25
Notes:
DHP
1 See DHP details in technical features page.
Upper bracket
B For PL < 950 = 100. For PL ≥ 950 = 160.
- If not otherwise indicated all dimensions in mm.
Lower bracket
15 www.fermator.com 40/10
Sales contacts
General: [email protected]
Spain: [email protected] • Brazil: [email protected] • Italy: [email protected] • France: [email protected], [email protected]
China: [email protected] • India: [email protected] • Poland: [email protected] • Germany: [email protected]
Middle East: [email protected] • Nordic countries: [email protected]
Fermator reserves the right to make changes to the specification of the products within this catalogue without prior notice.