1 Introduction
This checklist shall be used to make sure the amplifier is always checked in a proper way after
service has been done. It is important to follow the steps in this check list and check all points
so that the set up of parameters in the amplifier is correct adjusted. When have done all
checks and adjusted the parameters the amplifier will work properly and will have the output
power that it is designed for.
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB
2006 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN
Modified: 2009-11-04 Page 4 of 12
1) After repair always start the amplifier with current potentiometer (VR1) located on
PWMF1-board. On is clockwise (cw) and off is counter clockwise (ccw). Check that the
switch pulse is normal. 300V line should increase some volts when relay clicks.
VR1
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB
2006 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN
Modified: 2009-11-04 Page 5 of 12
5. Slowly turn variac up, at the same time look at power- 230VAC
supply oscilloscope.
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB
2006 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN
Modified: 2009-11-04 Page 6 of 12
8. Power supply frequency decreases, PAL led goes out. 23kHz 43µS
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB
2006 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN
Modified: 2009-11-04 Page 7 of 12
Step 9, 10
Only for C 16:4, C 28:4, C 48:4, C 68:4, C 88:4, FP 4000, FP 6000Q, FP 7000
& FP 10000Q.
9. Begin turning voltage adjust potentiometer. ca +/- 174V VR1-SP100F/
At 174V (+/- 2V) power supply will stop. VR1-SP130F
Adjustment point
Measuring points
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB
2006 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN
Modified: 2009-11-04 Page 8 of 12
Step 11, 12
Only for FP 9000, FP 13000 & FP 14000.
11. Begin turning voltage adjust potentiometer. ca +/- 220V VR1-SP130F
At 220V (+/- 2V) power supply will stop.
Adjustment point
Measuring points
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB
2006 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN
Modified: 2009-11-04 Page 9 of 12
Step 13
Only for C 16:4, C 28:4, C 48:4, C 68:4, C 88:4, FP 4000, FP 6000Q, FP 7000
& FP 10000Q.
13. Measure voltages according to chart:
1 GND -
2 ca 2V Trafotemp
3 +25V 15VUnr
4 GND -
5 +58V 50VUnr
6 -18V 50VUNrR
7 +15V Pwrgood
8 +5V PAL
Step 14
Only for FP 9000, FP 13000 & FP 14000.
14. Measure voltages according to chart:
1 GND -
2 ca 2V Trafotemp
3 +22-23V 15VUnr
4 GND -
5 +52-53V 50VUnr
6 -18V 50VUNrR
7 +15V Pwrgood
8 +5V PAL
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB
2006 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN
Modified: 2009-11-04 Page 10 of 12
15. Following tests are made for all Channels, check offset with
no input +/- 40mV.
Following tests are made for all Channels, check offset with
no input and no load +/- 2V.
Increase input signal and check output signal at clip 8Ω
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB
2006 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN
Modified: 2009-11-04 Page 11 of 12
No input signal
No input signal
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB
2006 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN
Modified: 2009-11-04 Page 12 of 12
4 Channels
2 Channels
20) Check gain potentiometers at front. No disturbance at output signal shall be detected when
turning the potentiometer from one end point to the other end point.
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB