0% found this document useful (0 votes)
215 views

AT yuyuSEICOS 2

This document provides step-by-step instructions for loading NC data from a computer to a Hitachi Seiki machine controller using AT-YUYU software. It describes preparing the computer and machine, setting communication settings, and transferring NC programs, parameters, and other data files from the computer to the machine's memory using the software.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
215 views

AT yuyuSEICOS 2

This document provides step-by-step instructions for loading NC data from a computer to a Hitachi Seiki machine controller using AT-YUYU software. It describes preparing the computer and machine, setting communication settings, and transferring NC programs, parameters, and other data files from the computer to the machine's memory using the software.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

SV03-999-69-010

FAQ
Machine Model: HITACHI SEIKI
Title: How to Load NC data by AT-YUYU SEICOS-2
Objective:
Publication: M/D/Y 12/13/02 Written by MORI SEIKI USA

Prepare
1. IBM/AT compatible computer. (Need MS-DOS. WindowsNT/2000/Me If you don’t have real
MS-DOS : No guarantee.)
2. RS232C cable. The wiring is as follows.
computer Female 9pin Machine Male 25pin
CD 1 1 FG
RD 2 2 TXD
SD 3 3 RXD
ER 4 4 RTS
SG 5 5 CTS
DR 6 6 DSR
RS 7 7 GND
CS 8 8 DCD
9 20 DTR(ER)
3. AT-YUYU software V4.70
4. NC data files
Setting of computer NC data
5. Connect machine RS232C port to computer RS232C port.
6. Power on computer and start Windows or MS-DOS.
7. Start MS-DOS Prompt.
8. If your computer runs in Japanese MS-DOS, Type C:\ > U S ENTER , then computer will
run in English mode.
9. Start AT-YUYU software.

10. Press F9(TRANSFER XCHG) .


SV03-999-69-010
FAQ
11. Set up it as follows.

PROTOCOL : FA
BAUDRATE : 9600
BIT :8
PARITY : NON
STOP :2
X_OFF(DC3) : 93H
AUX : NORM
NC-DC1 WAIT : NO
NCCODE XCHG : ISO
NC TERMINAT : LFCR2

12. Press F10 , Return to main screen.

13. Press F7(PATH AT) .

14. Select drive and folder that have saved NC files.


15. Press ENTER , Return to main screen.

Setting of SEICOS-2
16. Go to machine.
17. Press E-STOP.
18. Select MDI mode.
19. Press SET -> You will see SETTING DATA screen.
SV03-999-69-010
FAQ
20. Set up it same as follows.

PUNCH CODE : 1 (ISO)


TV CHECK : 0 (OFF)
DATA IN DEVICE : 0 (RS232C)
MEMORY OPEN : 1 (ON)

PORT : 0 (NK4)
IN BAUD RATE : 9600
OUT BAUD RATE : 9600
STOP BIT :2
DC CODE : 0 (USE)

21. Press PARAM -> You will see PARAMETER screen.


22. Set NC Parameter same as follows.
No.000 bit0 = 0 No001 bit0 = 0 No.15 bit7 = 0 No.16 bit7 = 0 No.305 bit0 = 0
No.000 bit1 = 1 No001 bit1 = 0 No.305 bit1 = 0
No.000 bit4 = 0 No001 bit2 = 0 No.305 bit2 = 0
No.000 bit5 = 0 No001 bit3 = 0 No.305 bit3 = 1
No001 bit4 = 0 No.305 bit4 = 0
No001 bit5 = 0 No.305 bit5 = 0
No.305 bit7 = 0
Load NC Data
23. Select EDIT mode.
SV03-999-69-010
FAQ
24. Press IN -> You will see DATA IN screen.

SEICOS-2 input Computer data


command file name

NC programs O-9999
PROGRAM.TXT
NC parameter PA PARAME.TXT
Tool offset TO TOOL.TXT
Work offset WO WORK.TXT
Macro value MA MACRO.TXT
Screen position A Tool life TL LIFE.TXT
All data AL ALL.TXT

25. If you want to load NC programs, do step25-1 ~ step25-8 .


25-1 Go to computer.
25-2. Press F1 (FREE TX) -> Select NC program file (Example : PROGRAM.TXT) by UP DOWN
key.

Example : load file name


NC programs : PROGRAM.TXT
NC parameter : PARAME.TXT
Save File Name Tool offset : TOOL.TXT
Work offset : WORK.TXT
Macro value : MACRO.TXT
Tool life : LIFE.TXT

All data without NC programs :


ALL.TXT

25-3. Press ENTER -> The computer shows Transmit data ([F:\PROGRAM.TXT] YUYU
machine) ? Y/any Until the next instructions (step 25-7), do not touch on the computer.
25-4. Go to machine.
25-5. Type - 9 9 9 9 INPUT (O-9999 on screen position A) -> SEICOS-2 start receiving.
25-6. Go to computer.
25-7. Press Y on computer -> Computer shows Transmitting data now... .
-> It start transfer NC all programs from computer to SEICOS-2
25-7 30. Go to Machine.
25-8. Finished , Press RESET
SV03-999-69-010
FAQ

26. If you want to load NC parameter,. do step26-1 ~ step26-8.


26-1 Go to computer.
26-2. Press F1 (FREE TX) -> Select NC parameter file (Example : PARAME.TXT) by UP DOWN
key.
26-3. Press ENTER -> The computer shows Transmit data ([F:\PARAME.TXT] YUYU
machine) ? Y/any
Until the next instructions(step 25-7) , Do not touch on the computer.
26-4. Go to machine.
26-5. Type P A INPUT (PA on screen position A) -> SEICOS-2 start receiving.
26-6. Go to computer.
26-7. Press Y on computer -> Computer shows Transmitting data now... .
-> It start transfer NC parameter from computer to SEICOS-2
26-7 30. Go to Machine.
26-8. Finished , Press RESET

27. If you want to load all NC data (without NC program), do step27-1 ~ step27-8.
27-1 Go to computer.
27-2. Press F1 (FREE TX) -> Select all NC data file (Example : ALL.TXT) by UP DOWN key.
27-3. Press ENTER -> The computer shows Transmit data ([F:\ALL.TXT] YUYU machine)?
Y/any. Until the next instructions (step 25-7), do not touch on the computer.
27-4. Go to machine.
27-5. Type A L INPUT (PA on screen position A) -> SEICOS-2 start receiving.
27-6. Go to computer.
27-7. Press Y on computer -> Computer shows Transmitting data now... .
-> It start transfer all NC data from computer to SEICOS-2
27-7 30. Go to Machine.
27-8. Finished , Press RESET

*If the SEICOS-2 does not receive NC data, please check as follows .
29-1. Is the cable same as our recommendation?
29-2. Is the RS232C port (COM1) working on your computer ?
[Start -> Settings -> Control Panel ->System -> Device Manager -> Ports
-> Communication Port (COM1) -> Properties]
29-3. In the case that an error has come out halfway the communication, your computer
should go to real MS-DOS mode.
[Start -> Shut Down -> Restart in MS-DOS mode -> Move prompt to the folder
that have AT-YUMO software -> Start ATYUMO.exe ]
28. Go to computer.
29. Press F10 of your computer. -> END? Y/any -> Press Y .