AT yuyuSEICOS 2
AT yuyuSEICOS 2
FAQ
Machine Model: HITACHI SEIKI
Title: How to Load NC data by AT-YUYU SEICOS-2
Objective:
Publication: M/D/Y 12/13/02 Written by MORI SEIKI USA
Prepare
1. IBM/AT compatible computer. (Need MS-DOS. WindowsNT/2000/Me If you don’t have real
MS-DOS : No guarantee.)
2. RS232C cable. The wiring is as follows.
computer Female 9pin Machine Male 25pin
CD 1 1 FG
RD 2 2 TXD
SD 3 3 RXD
ER 4 4 RTS
SG 5 5 CTS
DR 6 6 DSR
RS 7 7 GND
CS 8 8 DCD
9 20 DTR(ER)
3. AT-YUYU software V4.70
4. NC data files
Setting of computer NC data
5. Connect machine RS232C port to computer RS232C port.
6. Power on computer and start Windows or MS-DOS.
7. Start MS-DOS Prompt.
8. If your computer runs in Japanese MS-DOS, Type C:\ > U S ENTER , then computer will
run in English mode.
9. Start AT-YUYU software.
PROTOCOL : FA
BAUDRATE : 9600
BIT :8
PARITY : NON
STOP :2
X_OFF(DC3) : 93H
AUX : NORM
NC-DC1 WAIT : NO
NCCODE XCHG : ISO
NC TERMINAT : LFCR2
Setting of SEICOS-2
16. Go to machine.
17. Press E-STOP.
18. Select MDI mode.
19. Press SET -> You will see SETTING DATA screen.
SV03-999-69-010
FAQ
20. Set up it same as follows.
PORT : 0 (NK4)
IN BAUD RATE : 9600
OUT BAUD RATE : 9600
STOP BIT :2
DC CODE : 0 (USE)
NC programs O-9999
PROGRAM.TXT
NC parameter PA PARAME.TXT
Tool offset TO TOOL.TXT
Work offset WO WORK.TXT
Macro value MA MACRO.TXT
Screen position A Tool life TL LIFE.TXT
All data AL ALL.TXT
25-3. Press ENTER -> The computer shows Transmit data ([F:\PROGRAM.TXT] YUYU
machine) ? Y/any Until the next instructions (step 25-7), do not touch on the computer.
25-4. Go to machine.
25-5. Type - 9 9 9 9 INPUT (O-9999 on screen position A) -> SEICOS-2 start receiving.
25-6. Go to computer.
25-7. Press Y on computer -> Computer shows Transmitting data now... .
-> It start transfer NC all programs from computer to SEICOS-2
25-7 30. Go to Machine.
25-8. Finished , Press RESET
SV03-999-69-010
FAQ
27. If you want to load all NC data (without NC program), do step27-1 ~ step27-8.
27-1 Go to computer.
27-2. Press F1 (FREE TX) -> Select all NC data file (Example : ALL.TXT) by UP DOWN key.
27-3. Press ENTER -> The computer shows Transmit data ([F:\ALL.TXT] YUYU machine)?
Y/any. Until the next instructions (step 25-7), do not touch on the computer.
27-4. Go to machine.
27-5. Type A L INPUT (PA on screen position A) -> SEICOS-2 start receiving.
27-6. Go to computer.
27-7. Press Y on computer -> Computer shows Transmitting data now... .
-> It start transfer all NC data from computer to SEICOS-2
27-7 30. Go to Machine.
27-8. Finished , Press RESET
*If the SEICOS-2 does not receive NC data, please check as follows .
29-1. Is the cable same as our recommendation?
29-2. Is the RS232C port (COM1) working on your computer ?
[Start -> Settings -> Control Panel ->System -> Device Manager -> Ports
-> Communication Port (COM1) -> Properties]
29-3. In the case that an error has come out halfway the communication, your computer
should go to real MS-DOS mode.
[Start -> Shut Down -> Restart in MS-DOS mode -> Move prompt to the folder
that have AT-YUMO software -> Start ATYUMO.exe ]
28. Go to computer.
29. Press F10 of your computer. -> END? Y/any -> Press Y .
Finished