Liquid ring vacuum pumps

in compact design

LEM 90, LEM 125, LEM 150


LEL 90, LEL 125, LEL 150

Pressure range: 33 to 1013 mbar


Suction volume flow: 32 to 170 m³/h

CONSTRUCTION TYPE

SIHI liquid ring vacuum pumps are displacement pumps of


uncomplicated and robust construction with the following particular
features:
non-polluting due to nearly isothermal compression
oil-free, as no lubrication in the working chamber
handling of nearly all gases and vapours
small quantities of entrained liquid can be handled
easy maintenance and reliable operation
low noise and nearly free from vibration
wide choice of material, therefore applicable nearly everywhere
shaft not contact with the medium
protection against cavitation as standard
incorporated dirt drain
incorporated central drain
NOTE
no metallic contact of the rotating parts
The SIHI liquid ring vacuum pumps LEM/LEL are single-stage ones. During operation the pump must continuously be supplied with service
liquid, normally water, in order to eliminate the heat resulting from the
gas compression and to replenish the liquid ring, because part of the
liquid is leaving the pump together with the gas. This liquid can be
separated from the gas in a liquid separator (see catalogue part
accessories).
APPLICATION It is possible to reuse the service liquid. The pumps are equipped with
a device by which the contaminated service liquid can continuously be
Handling and exhausting of dry and humid gases; entrained liquid can drained during operation (dirt drain), if necessary.
be handled during normal duty. The pumps are applied in all fields
where a pressure of 33 to 900 mbar must be created by robust The direction of rotation is clockwise, when looking from the drive on
vacuum pumps. the pump.

GENERAL TECHNICAL DATA

Pump type unit LEM 90 LEM 125 LEM 150


LEL 90 LEL 125 LEL 150
Speed 50 Hz 1450
rpm
60 Hz 1750
Max. compression over pressure bar LEM 0,3 / LEL 0,5
Max. admissible pressure difference bar LEM 1,1 / LEL 1,5
Hydraulic test (over pressure) bar 3
Moment of inertial of the rotating .
kg m² 0,035 0,053 0,069
pump parts and of the water filling
Sound pressure level
at a suction pressure of 80 mbar dB (A) 65
Max. gas temperature dry °C 200
saturated °C 100
Service liquid
max. admissible temperature °C 80
max. viscosity mm²/s 4
max. density kg/m³ 1200
volume up to shaft level liter 2,4 2,8 3,2
Max. flow resistance
bar 0,2
of the heat exchanger

The combination of several limiting values is not admissible.

VACUUM TECHNOLOGY LEM/LEL LE 3B


133.71318.52.01 E 12/99
Material design

MATERIAL DESIGN
Item COMPONENTS 0A 4B

10.10 Casing
10.90 Central body 0.6025 1.4408
13.70 Guide disk
21.00* Shaft 1.0503
23.50 Vane wheel impeller 2.1096.01 1.4517
34.01* Motor carrier 0.6025 0.6025 (with annealing lacquer)
43.30 Standard mechanical seal Cr-steel / carbon / Perbunan Cr Ni Mo-steel / carbon / Viton
59.10 integrated pre-arranged 1.0038 1.4571
separator
75.40 Valve balls polyamide A PTFE
* only at LEL 90, 125, 150

Sectional drawing LEM 90, LEM 125, LEM 150

Sectional drawing LEM 90, LEM 125, LEM 150 with integrated pre-arranged separator

2
Sectional drawing LEL 90, LEL 125, LEL 150

Sectional drawing LEL 90, LEL 125, LEL 150 with integrated pre-arranged separator

Fresh water requirements in [m³/h] dependent on suction pressure, speed, mode of operation and difference in temperature

suction pressure
33 120 200 400
[mbar]
KB KB KB KB
difference in difference in difference in difference in
pump speed FB FB FB FB
temperature [°C] temperature [°C] temperature [°C] temperature [°C]
[rpm] 10 5 2 10 5 2 10 5 2 10 5 2
LEM / LEL 1450 0,12 0,22 0,41 1,0 0,14 0,24 0,44 0,95 0,14 0,25 0,44 0,9 0,15 0,24 0,41 0,75
90 1750 0,18 0,30 0,52 0,19 0,32 0,53 0,20 0,33 0,53 0,19 0,31 0,47
LEM / LEL 1450 0,17 0,28 0,50 1,0 0,19 0,31 0,52 0,95 0,19 0,31 0,51 0,9 0,18 0,29 0,46 0,75
125 1750 0,22 0,36 0,59 0,24 0,39 0,60 0,26 0,40 0,60 0,24 0,37 0,53
LEM / LEL 1450 0,19 0,32 0,54 1,0 0,22 0,36 0,58 0,95 0,23 0,37 0,57 0,9 0,23 0,35 0,51 0,75
150 1750 0,26 0,41 0,63 0,29 0,44 0,65 0,30 0,45 0,64 0,29 0,41 0,57

FB = fresh liquid service


KB = combined liquid service with service water 10 °C, 5 °C, 2 °C warmer than the fresh water.

3
Suction volume flow and power absorption LEM 90 / LEL 90

100

m³/h 1750 rpm

80
1450 rpm

60

40

20

LEM/LEL 90
0
10 40 60 80 100 200 400 mbar 1000
suction pressure

kW

1750 rpm

1450 rpm

LEM/LEL 90

0
10 40 60 80 100 200 400 mbar 1000
suction pressure

The operating data are applicable under the following conditions:

• pumping medium: - dry air: 20°C


- water vapour saturated air: 20°C

• service liquid: - water: 15°C

Compression pressure 1013 mbar (atmospheric pressure)


The suction volume flow is applied to the suction pressure
Tolerance of the operating data 10%
Max. fresh water need with lowest suction pressure

4
Suction volume flow and power absorption LEM 125 / LEL 125

140
m³/h 1750 rpm

120
1450 rpm
100

80

60

40

20
LEM/LEL 125
0
10 40 60 80 100 200 400 mbar 1000
suction pressure

6
kW
5

1750 rpm
3

1450 rpm
2

1
LEM/LEL 125

0
10 40 60 80 100 200 400 mbar 1000
suction pressure

The operating data are applicable under the following conditions:

• pumping medium: - dry air: 20°C


- water vapour saturated air: 20°C

• service liquid: - water: 15°C

Compression pressure 1013 mbar (atmospheric pressure)


The suction volume flow is applied to the suction pressure
Tolerance of the operating data 10%
Max. fresh water need with lowest suction pressure

5
Suction volume flow and power absorption LEM 150 / LEL 150

200

m³/h 1750 rpm

150
1450 rpm

100

50

LEM/LEL 150
0
10 40 60 80 100 200 400 mbar 1000
suction pressure

6
kW
5

4 1750 rpm

3
1450 rpm

1
LEM/LEL 150

0
10 40 60 80 100 200 400 mbar 1000
suction pressure

The operating data are applicable under the following conditions:

• pumping medium: - dry air: 20°C


- water vapour saturated air: 20°C

• service liquid: - water: 15°C

Compression pressure 1013 mbar (atmospheric pressure)


The suction volume flow is applied to the suction pressure
Tolerance of the operating data 10%
Max. fresh water need with lowest suction pressure

6
Dimension table LEM 90, LEM 125, LEM 150

Dimension table LEM 90, LEM 125, LEM 150 with integrated pre-arranged separator

N1 = gas inlet DN 40 use = connection for dirt drain G 3/8


N2 = gas outlet DN 40 ul = connection for vent cock G ½
uA = connection for liquid drain G 1¼ um = connection for pressure gauge G 3/8
uB = connection for service liquid G ½ um1 = connection for drain valve G 3/8
3
uc = connection for protection against cavitation G /8 ut = connection for thermometer G ½
ue = drain connection G 3/8

electric motor IP 55 weight abt. kg


kW f1 f2 h1 h2 h3 h4* m m1 m2 m3 m4 m5 n n1 n2 n3 o3 w* w1* w2* LEM +integr. pre-
size arranged
50 Hz 60 Hz separator
LEM 90 100 L 2,2 3,3 199 149 136 514 718 55 64
100 13 254 43 38 195 160 220 303
100 L 3,0 - 208 158 523 727 62 71
LEM 125 22 176 140 280 240 58 145
112 M - 4,8 215 265 540 744 68 77
112 15 279 45 44 225 190 250 320
112 M 4,0 - 232 282 557 761 70 79
LEM 150 162
132 M - 6,0 272 222 132 18 28 320 88 218 178 320 278 - 55 256 216 276 426 663 867 95 104
* dimensions dependent on the motor make
** see list of accessories
other motors on request
flange connections see page 10

7
Dimension table LEL 90, LEL 125, LEL 150

Dimension table LEL 90, LEL 125, LEL 150 with integrated pre-arranged separator

N1 = gas inlet DN 40 use = connection for dirt drain G 3/8


N2 = gas outlet DN 40 ul = connection for vent cock G ½
uA = connection for liquid drain G 1¼ um = connection for pressure gauge G 3/8
uB = connection for service liquid G ½ um1 = connection for drain valve G 3/8
3
uc = connection for protection against cavitation G /8 ut = connection for thermometer G ½
3
ue = drain connection G /8

electric motor 50 Hz weight abt. kg


size kW f1 o3 w1 w2 w3 E M N P LEL + integr.pre-
arranged
IP 55 EEx e ll T3 separator
LEL 90 100 L 2,2 2,5 182 136 541 466 745 60 72
LEL 125 100 L 3,0 - 191 145 550 475 754 62 215 180 250 63 75
112 M - 3,6
LEL 150 112 M 4,0 - 208 162 567 492 771 67 79
132 S - 5,0 587 512 791 82 265 230 300
other motors on request
flange connections see page 10

8
Arrangement drawing LEM 90, LEM 125, LEM 150

electric motor IP 55 weight


size kW abt. kg
50 Hz 60 Hz N1 = gas inlet DN 40
LEM 90 100 L 2,2 3,3 65 N2 = gas outlet DN 50
LEM 125 100 L 3,0 - 72 uA = connection for liquid drain G 1
112 M - 4,8 78 uA1 = connection for liquid drain G ½
LEM 150 112 M 4,0 - 80 uF = connection for fresh liquid G ½
3
132 M - 6,0 105 uc = connection for protection against cavitation G /8
** see list of accessories
other motors on request
flange connections see page 10

9
Arrangement drawing LEL 90, LEL 125, LEL 150

electric motor 50 Hz weight


size kW w* w2 abt. kg
IP 55 EEx e ll T3 N1 = gas inlet DN 40
LEL 90 100 L 2,2 2,5 303 466 91 N2 = gas outlet DN 50
LEL 125 100 L 3,0 - 475 98 uA = connection for liquid drain G 1
112 M - 3,6 320 104 uA1 = connection for liquid drain G ½

LEL 150 112 M 4,0 - 492 106 uF = connection for fresh liquid G ½
3
132 S - 5,0 405 512 141 uc = connection for protection against cavitation G /8

flange connections to DIN 2501 PN 10

DN 40 50
k 110 125
D 150 165
number x d2 4 x 18 4 x 18
* dimensions dependent on the motor make
** see list of accessories
other motors on request

10
Data regarding the pump size - order hints

series +
hydraulics + bearings shaft sealing material design casing seal
size

A• hydraulics A
R• with integrated pre-
arranged separator AAE mechanical seal 0A main parts of GG
O-rings Perbunan
•Z two grease lubricated
antifriction bearings 4B main parts of 0 liquid seal
arranged in the motor AA1 as AAE, but Cr Ni Mo-cast steel
O-rings Viton
•B as •Z but arranged
in the motor carrier

90
LEM 125 AZ, RZ
150
AAE, AA1 0A, 4B 0
90
LEL 125 AB, RB
150

Motor selection table for LEM

motor enclosure IP 55 50 Hz motor enclosure IP 55 60 Hz


Y-voltage ∆-voltage power size motor- Y-voltage ∆-voltage power size motor-
V +/- 5% V +/- 5% kW design. V +/- 5% V +/- 5% kW design.
LEM 90 346-440 200-254 2,2 100 L BW 346-480 200-277 3,3 100 L BX
LEM 125 346-440 200-254 3,0 100 L KW 346-480 200-277 4,8 112 M MX
LEM 150 660-725 380-420 4,0 112 M CX --- 380-480 6,0 132 M DX

Example for ordering:

The construction size LEM 125 AZ AAE 0A 0 with 3 kW three-phase ac motor (50 Hz, 230 V∆) 1450 rpm
has the complete order number: LEM• 125 AZ AAE 0A 0 KW

Design for LEL

designation electric motor 50 Hz

pump with free shaft end 01 motor enclosure IP 55 motor enclosure EEx e ll T3
pump with coupling, pre-drilled at motor side 04 kW size designation kW size designation
as above, but with motor, for example 2,2 100 L KB 2,5 100 L LK
3,0 kW three-phase motor i.e. LB 3,0 100 L LB 3,6 112 M MK
(50 Hz, 230 V∆) at 1450 rpm 4,0 112 M MB 5,0 132 S NK

Example for ordering:

The construction size LEL 125 AB AAE 0A 0 with 3 kW three-phase ac motor (50 Hz, 230 V∆) 1450 rpm
has the complete order number: LEL• 125 AB AAE 0A 0 LB

If motors with other voltage or frequency are required a special information should be given.

On delivery the point (•) in the fourth place of the type cope is replaced by a letter in the factory.

11
Accessories LEM 90, LEM 125, LEM 150

LEM 90 LEM 125 LEM 150


Recommended accessories
LEL 90 LEL 125 LEL 150

Overhead liquid separator type XBa 1042


weight 9,7 kg
material design 130 / galvanized SIHI part No. 35 000 396
172 / 1.4571 35 000 397
service liquid line
material design 072 / St 37-0 SIHI part No. 35 003 244
172 / 1.4571 35 007 969
cavitation protection line
material design 072 / St 37-0 SIHI part No. 35 003 599
172 / 1.4571 35 003 600

Upright liquid separator type XBp 413


weight 28 kg
material design 130 / galvanized SIHI part No. 35 000 502
172 / 1.4571 35 000 503
service liquid line
material design 072 / St 37-0 SIHI part No. 35 009 418
172 / 1.4571 35 005 534
discharge line (bend)
material design 072 / St 37-0 SIHI part No. 35 003 172
172 / 1.4571 35 005 535
cavitation protection line
material design 072 / St 37-0 SIHI part No. 20 041 543
172 / 1.4571 20 041 544
SIHI-gas ejector
at service liquid temperature 15 °C GEV 90 A GEV 125 A GEV 150 A
at service liquid temperature 30 °C GEV 90 B GEV 125 B GEV 150 B
SIHI ball type non-return valve type / weight XCk 40 / 2,8 resp. 5,2 kg
material design 767 / GG 25 SIHI part No. 43 016 890
784 / 1.4408 43 030 996
Support foot only for series LEM
for motor size 100 L, 112 M SIHI part No. 20 047 010 20 047 010
for motor size 132 M - 20 047 012
Standard motor only for series LEL
IP 55 size 100 L 100 L 112 M
power 2,2 kW 3,0 kW 4,0 kW
weight 18 kg 20 kg 28 kg

EEx e ll T3 size 100 L 112 M 132 S


power 2,5 kW 3,6 kW 5,0 kW
weight 22 kg 30 kg 65 kg
Coupling only for series LEL
for motor IP 55 type / weight B 80 / 1,5 kg
pump side SIHI part No. 43 021 414
motor side 43 021 417

for motor EEx e ll T3 type / weight BDS 88 / 1,9 kg BDS 103 / 3,1 kg
pump side SIHI part No. 43 028 112 43 026 564
motor side 43 024 707 43 025 941
Intermediate flange only for series LEL
for motor flange ∅ 300 081 / 1.0038 SIHI part No. 20 043 024
058 /stove enamel 20 045 646

Any changes in the interest of the technical development are reserved.

Sterling SIHI GmbH


Lindenstraße 170 , D-25524 Itzehoe, Germany , Telephone +49 (0) 48 21 / 7 71-01 , Fax +49 (0) 48 21 / 7 71-274

12

You might also like