2 ELN 131 Quiz 3 4-3-24 Power Supplies W-O Locationinfo
2 ELN 131 Quiz 3 4-3-24 Power Supplies W-O Locationinfo
4/2/24
1. T/F Since diodes only conduct in one direction they serve well as rectifiers.
2. Referring to figure 1 below, draw in diodes to resolve the circuit into a center tapped,
full-wave rectifier and draw the waveform appearing across the load resistor, R L.
3. Draw the circuit of a bridge rectifier including the diodes and load resistor. Include a
graph of the input and out put waveforms.
7. Referring to the sinusoidal wave below, fill in the missing information noted by the
underlines.
8. A transformer has five times as many turns in the primary as the secondary. If 120VAC is
across the primary, what would the secondary voltage be?
11. The diode loss in a bridge rectifier is ______________ that of other circuits because
___________ diodes are always _____________ and are in ____________,
a. twice, two, conducting, series
b. the same as, rectifier, parallel, conduction
c. negligible as, Zener, conducting, series
d. twice, rectifier, separate, the same circuit
14. What is the time constant associated with a 100-µF and a 1000-µF capacitor when they are used
to filter a 60-Hz half-wave rectifier loaded by a 100 Ω load.
15. Choose a filter capacitor for a full wave 60 Hz power supply when the load current is 5A and the
allowable ripple is 1 VP-P.
16. T/F With pulsating direct current, a dc voltmeter will read the rms value of the waveform.
17. T/F The conversion factors 0.45 and 0.90 are not used to predict the dc output voltage of
filtered power supplies.
18. T/F A transformer has 120 V alternating current across its primary and 40 V ac across its
secondary. It is a step-down transformer.
19. When a stable voltage is required, the power supply must be regulated. Identify the statements
that are true of a regulator in a power supply.
a. A Zener is used in some applications
b. The regulator is connected in parallel with the load
c. A Schottky diode is used in most applications as a regulator
d. The regulator is connected in series with the load