0% found this document useful (0 votes)
12 views13 pages

ATV630U15N4 Document

The document provides product specifications for the Altivar Process ATV630U15N4 variable speed drive, including technical characteristics, protection features, communication capabilities, and electrical connections. It contains detailed information on the key aspects of this 1.5 kW ATV630 drive variant.

Uploaded by

Raulito Raulito
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
12 views13 pages

ATV630U15N4 Document

The document provides product specifications for the Altivar Process ATV630U15N4 variable speed drive, including technical characteristics, protection features, communication capabilities, and electrical connections. It contains detailed information on the key aspects of this 1.5 kW ATV630 drive variant.

Uploaded by

Raulito Raulito
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 13

Sep 13, 2022

Characteristics
Product data sheet

type 1
ATV630U15N4
ATV630, 1.5kW/2 hp, 380...480 V, IP21/UL

1
Variable speed drive, Altivar Process ATV600,

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Main
Range of Product Altivar Process ATV600
Product or Component Variable speed drive
Type
Product Specific Process and utilities
Application
Device short name ATV630
Variant Standard version
Product destination Asynchronous motors
Synchronous motors
EMC filter Integrated 164.04 ft (50 m) EN/IEC 61800-3
category C2
Integrated 492.13 ft (150 m) EN/IEC 61800-3
category C3
IP degree of protection IP21IEC 61800-5-1
IP21IEC 60529
[Us] rated supply 380...480 V
voltage
Degree of protection UL type 1 UL 508C
Type of cooling Forced convection
Supply frequency 50...60 Hz - 5...5 %
[Us] rated supply 380...480 V - 15...10 %
voltage
Motor power kW 1.5 KW normal duty)
0.75 kW heavy duty)
Maximum Horse Power 2 Hp normal duty
Rating 1 hp heavy duty
Line current 3 A 380 V normal duty)
2.6 A 480 V normal duty)
1.7 A 380 V heavy duty)
1.5 A 480 V heavy duty)
Prospective line Isc 50 kA
Apparent power 2.2 KVA 480 V normal duty)
1.2 kVA 480 V heavy duty)
Continuous output 4 A 4 kHz normal duty
current 2.2 A 4 kHz heavy duty
Maximum transient 4.4 A 60 s normal duty)
current 3.3 A 60 s heavy duty)
Asynchronous motor Variable torque standard
control profile Constant torque standard
Optimized torque mode
Synchronous motor Permanent magnet motor
control profile Synchronous reluctance motor
Speed drive output 0.1…500 Hz
frequency
Nominal switching 4 kHz
frequency
Switching frequency 2...12 kHz adjustable
4...12 kHz with derating factor
Safety function STO (safe torque off) SIL 3
Discrete input logic 16 preset speeds

2
Communication Port Modbus TCP
Protocol Ethernet
Modbus serial
Option card Slot A communication module, Profibus DP V1
Slot A communication module, PROFINET
Slot A communication module, DeviceNet
Slot A communication module, Modbus TCP/
EtherNet/IP
Slot A communication module, CANopen daisy
chain RJ45
Slot A communication module, CANopen SUB-D 9
Slot A communication module, CANopen screw
terminals
Slot A/slot B digital and analog I/O extension module
Slot A/slot B output relay extension module
Slot A communication module, Ethernet IP/Modbus
TCP/MD-Link
Communication module, BACnet MS/TP
Communication module, Ethernet Powerlink

Complementary
Mounting Mode Wall mount
Phase 3 phase
Discrete output number 0
Discrete output type Relay outputs R1A, R1B, R1C 250 V AC 3000 mA
Relay outputs R1A, R1B, R1C 30 V DC 3000 mA
Relay outputs R2A, R2C 250 V AC 5000 mA
Relay outputs R2A, R2C 30 V DC 5000 mA
Relay outputs R3A, R3C 250 V AC 5000 mA
Relay outputs R3A, R3C 30 V DC 5000 mA
Output voltage <= power supply voltage
Permissible temporary current boost 1.1 x In 60 s normal duty)
1.5 x In 60 s heavy duty)
Motor slip compensation Can be suppressed
Adjustable
Not available in permanent magnet motor law
Automatic whatever the load
Acceleration and deceleration ramps Linear adjustable separately from 0.01...9999 s
Physical interface Ethernet
2-wire RS 485
Braking to standstill By DC injection
Protection type Thermal protection motor
Safe torque off motor
Motor phase break motor
Thermal protection drive
Safe torque off drive
Overheating drive
Overcurrent between output phases and earth drive
Overload of output voltage drive
Short-circuit protection drive
Motor phase break drive
Overvoltages on the DC bus drive
Line supply overvoltage drive
Line supply undervoltage drive
Line supply phase loss drive
Overspeed drive
Break on the control circuit drive
Transmission Rate 10, 100 Mbits
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Frequency resolution Display unit 0.1 Hz
Analog input 0.012/50 Hz
Transmission frame RTU
Electrical connection Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16
Motor screw terminal 2.5...6 mm² AWG 14...AWG 10
Line side screw terminal 2.5...6 mm² AWG 14...AWG 10
Connector type RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
RJ45 on the remote graphic terminal)Modbus serial
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
Exchange mode Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP

3
Number of addresses 1…247 Modbus serial
Method of access Slave Modbus TCP
Supply External supply for digital inputs 24 V DC 19…30 V), <1.25 mA overload and
short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %,
<10 mA overload and short-circuit protection
Internal supply for digital inputs and STO 24 V DC 21…27 V), <200 mA overload
and short-circuit protection
Local signalling For local diagnostic 3 LEDs
For embedded communication status 3 LEDs (dual colour)
For communication module status 4 LEDs (dual colour)
For presence of voltage 1 LED (red)
Width 5.67 in (144 mm)
Height 13.78 in (350 mm)
Depth 7.99 in (203 mm)
Net Weight 9.92 lb(US) (4.5 kg)
Analogue input number 3
Analogue input type AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits
AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits
AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Discrete input number 8
Discrete input type DI7, DI8 programmable as pulse input 0…30 kHz, 24 V DC <= 30 V)
Input compatibility DI1...DI6 discrete input level 1 PLC EN/IEC 61131-2
DI5, DI6 discrete input level 1 PLC IEC 65A-68
STOA, STOB discrete input level 1 PLC EN/IEC 61131-2
Discrete input logic Positive logic (source) DI1...DI8), < 5 V, > 11 V
Negative logic (sink) DI1...DI8), > 16 V, < 10 V
Analogue output number 2
Analogue output type Software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits
Software-configurable current AQ1, AQ2 0...20 mA 10 bits
Software-configurable current DQ-, DQ+ 30 V DC
Software-configurable current DQ-, DQ+ 100 mA
Sampling duration 2 Ms +/- 0.5 ms DI1...DI4) - discrete input
5 Ms +/- 1 ms DI5, DI6) - discrete input
5 Ms +/- 0.1 ms AI1, AI2, AI3) - analog input
10 ms +/- 1 ms AO1) - analog output
Accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Linearity error AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
AO1, AO2 +/- 0.2 % analog output
Relay output number 3
Relay output type Configurable relay logic R1 fault relay NO/NC 100000 cycles
Configurable relay logic R2 sequence relay NO 100000 cycles
Configurable relay logic R3 sequence relay NO 100000 cycles
Refresh time Relay output R1, R2, R3)5 ms +/- 0.5 ms)
Minimum switching current Relay output R1, R2, R3 5 mA 24 V DC
Maximum switching current Relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC
Relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC
Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Isolation Between power and control terminals
Maximum output frequency 500 kHz
Maximum Input Current per Phase 3.0 A

4
Variable speed drive application selection Compressor centrifugal Building - HVAC
Other application Food and beverage processing
Fan Mining mineral and metal
Pump Mining mineral and metal
Fan Oil and gas
Other application Water and waste water
Screw compressor Building - HVAC
Pump Food and beverage processing
Fan Food and beverage processing
Atomization Food and beverage processing
Electro submersible pump (ESP) Oil and gas
Water injection pump Oil and gas
Jet fuel pump Oil and gas
Compressor for refinery Oil and gas
Centrifuge pump Water and waste water
Positive displacement pump Water and waste water
Electro submersible pump (ESP) Water and waste water
Screw pump Water and waste water
Lobe compressor Water and waste water
Screw compressor Water and waste water
Compressor centrifugal Water and waste water
Fan Water and waste water
Conveyor Water and waste water
Mixer Water and waste water
Motor power range AC-3 1.1…2 KW 380…440 V 3 phase
1.1…2 kW 480…500 V 3 phase
Quantity per Set 1
Enclosure mounting Wall mounted

Environment
Insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
Noise level 54.5 dB 86/188/EEC
Power dissipation in W Natural convection 28 W 380 V 4 kHz
Forced convection 41 W 380 V 4 kHz
Volume of cooling air 10038.72 Gal/hr(US) (38 m3/h)
Operating position Vertical +/- 10 degree
Maximum THDI <48 % full load IEC 61000-3-12
Electromagnetic compatibility Electrostatic discharge immunity test level 3 IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 IEC
61000-4-3
Electrical fast transient/burst immunity test level 4 IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5
Conducted radio-frequency immunity test level 3 IEC 61000-4-6
Pollution degree 2 EN/IEC 61800-5-1
Vibration resistance 1.5 mm peak to peak 2…13 Hz)IEC 60068-2-6
1 gn 13…200 Hz)IEC 60068-2-6
Shock resistance 15 gn 11 ms IEC 60068-2-27
Relative humidity 5…95 % without condensation IEC 60068-2-3
Ambient air temperature for operation 5…122 °F (-15…50 °C) without derating)
122…140 °F (50…60 °C) with derating factor)
Ambient Air Temperature for Storage -40…158 °F (-40…70 °C)
Operating altitude <= 3280.84 ft (1000 m) without derating
1000...4800 m with current derating 1 % per 100 m
Standards UL 508C
EN/IEC 61800-3
Environment 1 category C2 EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 61000-3-12
IEC 60721-3
IEC 61508
IEC 13849-1
Product Certifications ATEX INERIS
DNV-GL
ATEX zone 2/22
UL
CSA
TÜV
Marking CE

5
Standards UL 508C
EN/IEC 61800-3
EN/IEC 61800-3 environment 1 category C2
EN/IEC 61800-3 environment 2 category C3
EN/IEC 61800-5-1
IEC 61000-3-12
IEC 60721-3
IEC 61508
IEC 13849-1
Overvoltage category III
Regulation loop Adjustable PID regulator
Noise level 54.5 dB
Pollution degree 2

Ordering and shipping details


Category 22205-ATV630 FRAMES 1 & 2
Discount Schedule CP4E
GTIN 3606480758102
Nbr. of units in pkg. 1
Package weight(Lbs) 12.68 lb(US) (5.751 kg)
Returnability Yes
Country of origin ID

Packing Units
Unit Type of Package 1 PCE
Package 1 Height 12.40 in (31.5 cm)
Package 1 width 7.48 in (19.0 cm)
Package 1 Length 15.94 in (40.5 cm)
Unit Type of Package 2 P06
Number of Units in Package 2 6
Package 2 Weight 104.73 lb(US) (47.506 kg)
Package 2 Height 28.94 in (73.5 cm)
Package 2 width 31.50 in (80.0 cm)
Package 2 Length 23.62 in (60.0 cm)

Offer Sustainability
Sustainable offer status Green Premium product
California proposition 65 WARNING: This product can expose you to chemicals including: Lead and
lead compounds, which is known to the State of California to cause cancer
and birth defects or other reproductive harm. For more information go to
www.P65Warnings.ca.gov
REACh Regulation
REACh Declaration
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS
Declaration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End Of Life Information
WEEE The product must be disposed on European Union markets following specific
waste collection and never end up in rubbish bins.
Upgradeability
Upgraded Components Available

6
Product data sheet ATV630U15N4
Dimensions Drawings

Dimensions

Drives with IP21 Top Cover


Right and Front Views

Drives Without IP21 Top Cover


Left and Rear Views

7
Product data sheet ATV630U15N4
Mounting and Clearance

Clearances

X1 X2 X3

≥ 100 mm (3.94 in.) ≥ 100 mm (3.94 in.) ≥ 10 mm (0.39 in.)

Mounting Types

Mounting Type A: Individual IP21

a ≥ 100 mm (3.94 in.)

8
Mounting Type B: Side by Side IP20

Mounting Type C: Individual IP20

a≥ 0

9
Product data sheet ATV630U15N4
Connections and Schema

Three-Phase Power Supply with Upstream Breaking via Line Contactor

Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance
with standard IEC/EN 60204-1

(1) Line choke if used


(2) Use relay R1 set to operating state Fault to switch Off the product once an error is detected.
A1 : Drive
KM1 : Line Contactor
Q2, Q3 : Circuit breakers
S1, S2 : Pushbuttons
T1 : Transformer for control part

Three-Phase Power Supply with Downstream Breaking via Contactor

Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance
with standard IEC/EN 60204-1

(1) Line choke if used


(2) Use relay R1 set to operating state Fault to switch Off the product once an error is detected.
A1 : Drive
KM1 : Contactor

10
Control Block Wiring Diagram

(1) Safe Torque Off


(2) Analog Output
(3) Digital Input
(4) Reference potentiometer
(5) Analog Input
R1A, R1B, R1C : Fault relay
R2A, R2C : Sequence relay
R3A, R3C : Sequence relay

Sensor Connection
It is possible to connect either 1 or 3 sensors on terminals AI2 or AI3.

Sink / Source Switch Configuration

The switch is used to adapt the operation of the logic inputs to the technology of the programmable controller outputs.
● Set the switch to Source (factory setting) if using PLC outputs with PNP transistors.
● Set the switch to Ext if using PLC outputs with NPN transistors.

Switch Set to SRC (Source) Position Using the Output Power Supply for the Digital Inputs

11
Switch Set to SRC (Source) Position and Use of an External Power Supply for the DIs

Switch Set to SK (Sink) Position Using the Output Power Supply for the Digital Inputs

Switch Set to EXT Position Using an External Power Supply for the DIs

12
Product data sheet ATV630U15N4
Performance Curves

Derating Curves

40 °C (104 °F) - Mounting type A, B and C


50 °C (122 °F) - Mounting type A, B and C
60 °C (140 °F) - Mounting type B and C
In : Nominal Drive Current