The document provides safety precautions for using a PLC module and related components. It lists various manuals and documents, and specifies performance specifications for the module such as interface type, media access, topology, encoding method, cable type, transmission specifications, and maximum node numbers.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
83 views

Smart Io

The document provides safety precautions for using a PLC module and related components. It lists various manuals and documents, and specifies performance specifications for the module such as interface type, media access, topology, encoding method, cable type, transmission specifications, and maximum node numbers.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

 Safety Precautions

DATA SHEET ► Safety Precautions is for using the product safely and correctly in order to prevent
Related Manual
Read this data sheet carefully prior to any operation, mounting, installation or start-up of the
2. Performance Specifications

the accidents and danger, so please go by them. product. Performance spec.


LS Programmable Logic Controller ► The precautions explained here only apply to this module. For safety precautions Name Code Items
GPL-D22C/D24C/DT4B/C/TR2B/C/TR4B/C/RY2C
on the PLC system, refer to User’s manual. GLOFA-GMWIN Programming software 10310000318 Standard EN50170 / DIN 19245
Pnet(Profibus-DP) I/F Module ► The precautions are divided into 2 sections, ‘Warning’ and ‘Caution’. Each of the
GLOFA-GMWIN Instruction & Programming 10310000377 Interface RS-485(Electric)
GLOFA-GM/MASTER-K Smart I/O User’s manual 10310000353 Media Access POLL
meanings is represented as follows. GLOFA-GM Pnet I/F Module User’s Manual 10310000334 Topologe BUS Type
KGLWIN(Programming software) 10310000345 Encording Method
NRZ
If you violate instructions, it can cause death, fatal injury or a MASTER-K Instruction & Programming 10310000346 Cable type Twisted Pair Shielded Cable
Smart I/O GPL-TR2B Warning considerable loss of property XG5000 Programming software 10310000512 1200m(9.6k ~ 187.5 kbps)
Transmission
GPL-TR4B XGK/XGB Instruction & Programming 10310000510
spec. Comm. Distance 400m(500kbps)
If you violate instructions, it can cause a slight injury or a slight XGI/XGR/XEC Instruction & Programming 10310000833 200m(1.5Mbps)
GPL-DT4B Caution loss of products XGK CPU series 10310000508 Max. Node
99
GPL-D22C XGI CPU series 10310000832 number
XGB Hardware 10310000893 Max. Node
GPL-D24C ► The symbols which are indicated in the PLC and User’s Manual mean as follows. XGB Hardware (IEC) 10310000981 number 32
This symbol means paying attention because of danger of injury, fire, XGT Pnet I/F Module User’s Manual 10310000636 (per segment)
GPL-DT4C or malfunction Smart I/O user manual 10310000353 Max. I/O Data Input : 4Byte / Output : 4Byte
GPL-TR2C ► This symbol means paying attention because of danger of electric shock. External current
GPL-D22C : 70 / GPL-D24C : 85
GPL-DT4B/C : 100 / GPL-TR2B/C : 85
GPL-TR4C Store this datasheet in a safe place so that you can take it out and read Revision History consumption(mA)
GPL-TR4B/C : 115 / GPL-RY2C : 160
it whenever necessary. Always forward it to the end user Publication Version Description Basic spec
GPL-RY2C 2003.07. V1.0 The first edition
GPL-D22C : 188 / GPL-D24C : 286
 Handing Precautions Weight(g) GPL-DT4 B/C : 254/284 /GPL-TR2 B/C : 160/189
2005.06. V1.1 Head office address and Group CI changed GPL-TR4 B/C : 255/285 / GPL-RY2C : 332
► Don’t drop or make impact. 2009.08. V2.0 Branch address changed
► Don’t detach PCB from case. It may cause problem. KOREAN/ENGLISH data sheet integrated
2011.05 V3.0
CI Changed
► When wiring, let no foreign material go into the module. If it goes into the module, Terminal block screwing torque added 3. Cable Specifications
remove it. 2013.11 V3.1
Domain of Homepage changed (1) Belden Network Cable
► Don’t detach the module from slot while power is on 2014.04 V3.2 Terminal block drawing edited. (a) Type : Network Components
(b) Protocol : FMS-DP-PA
- When using LSIS equipment, thoroughly read this 1. General Specifications (c) Certification : No
Warning (d) Order No. : 3077F, 3079A
datasheet and associated manuals introduced in this
► Do not contact the terminals while the power is applied. No Item Specification Standard Item Twinax
datasheet. Also pay careful attention to safety and handle Risk of electric shock and malfunction. Operating AWG 22
1 0 ~ 55℃ -
the module properly. temperature Type BC-Bare Copper
► Protect the product from being gone into by foreign metallic matter.
Storage Insulation
- Store this datasheet in a safe place so that you can take it Risk of fire, electric shock and malfunction. 2 -25 ~ 70℃ - PE-Polyethylen
temperature Method
out and read it whenever necessary. ► Risk of fire, electric shock and malfunction. Operating Insulation
0.035 (Inch)
3 5 ~ 95%RH, non-condensing - Thickness
Risk of injury and fire by explosion and ignition. humidity
Storage Aluminum Foil-
4 5 ~ 95%RH, non-condensing - Shield Polyester Tape/Braid
humidity
For discontinuous vibration - - Shield
Frequency Acceleration Amplitude times Capacity 8500㎊/ft
10≤f∠57 Hz - 0.075 mm Characteristic
150Ω
Vibration 57 ≤f≤150 Hz 9.8㎨ (1G) - 10 times in Impedance
5 each Core 2 Core
resistance For continuous vibration IEC61131-2
• HEAD OFFICE Caution direction
Frequency Acceleration Amplitude
for
LS Tower, 127, LS-ro, Dongan-gu, Anyang-si,Gyeonggi-do, 431-848, Korea 10≤f∠57 Hz - 0.035 mm
► Be sure to check the rated voltage and terminal arrangement for the X, Y, Z
Tel: 82-2-2034-4870 Fax: (82-2)2034-4648 e-mail: [email protected] 57≤f≤150 Hz 4.9㎨(0.5G) - (2) Connector
module before wiring work.
• Max. impact acceleration : 147 ㎨ (15G)
Risk of electric shock, fire and malfunction. • Authorized time : 11㎳
• LSIS(ME) FZE _ Dubai, U.A.E. 6
Shocks
IEC61131-2
Tel: 971-4-886-5360 Fax: 971-4-886-5361 e-mail: [email protected] ► Tighten the screw of terminal block with the specified torque range. resistance • Pulse wave : Sign half-wave pulse
If the terminal screw is loose, it can cause fire and electric shock. (Each 3 times in X,Y,Z directions)
Square wave AC: ±1,500V LSIS
• LSIS Tokyo Office _ Tokyo, Japan ► Use the PLC in an environment that meets the general impulse noise DC: ±900V standard
Tel: 81-3-3582-9128 Fax: 81-3-3582-2667 e-mail: [email protected] specifications contained in this datasheet. Electrostatic IEC61131-2
Voltage: 4kV (Contact discharge)
Risk of electrical shock, fire, erroneous operation and deterioration of the discharge IEC61000-4-2
PLC. Radiated
• LSIS Shanghai Office _ Shanghai, China Noise electromagnetic 80 ~ 1,000 MHz, 10 V/m
IEC61131-2
Tel: 86-21-5237-9977(609) Fax: 89-21-5237-7189 e-mail: [email protected] ► Be sure that external load does not exceed the rating of output 7 IEC61000-4-3
resistance field noise
module. Digital/analog
Power
• LSIS Beijing Office _ Beijing, China Risk of fire and erroneous operation. input/output
Fast transient Segment supply IEC61131-2
communication
Tel: 86-10-5825-6027(666) Fax: 86-10-5825-6028 e-mail: [email protected] ► Do not use the PLC in the environment of direct vibration /burst noise module IEC61000-4-4
interface
Risk of electrical shock, fire and erroneous operation. Voltage 2 kV 1 kV
• LSIS Guangzhou Office _ Guangzhou, China ► Do not disassemble, repair or modify the PLC. Ambient
8 No corrosive gas or dust -
Tel: 86-20-8328-6754 Fax: 86-20-8326-6287 e-mail: [email protected] Risk of electrical shock, fire and erroneous operation conditions 4. Wiring of communication cable
Operating
► When disposing of PLC and battery, treat it as industrial waste. 9 2000m or less - (1) Wiring and Termination
height
• LSIS Chengdu Office _ Chengdu, China Risk of poisonous pollution or explosion. Pollution (a) Please connect a GREEN line to A1,A2 and a RED line to B1,B2 in general.
Tel: 86-20-8328-6754 Fax: 86-20-8326-6287 e-mail: [email protected] 10 2 or less - In addition, Shield is connected to the clamp of connector.
degree
Cooling (b) Please use cable of over 80% shield density.
• LSIS Qingdao Office _ Qingdao, China
 Precautions for use 11
type
Natural air cooling -
(c) Please ensure that you have terminated both ends of each segment.
► Do not Install other places except PLC controlled place. (d) If there are more than 0ne segment, it is necessary that you should
Tel: 86-532-8501-6068 Fax: 86-532-8501-6057 e-mail: [email protected]
► Make sure that the FG terminal is grounded with class 3 grounding which is terminate every segment.
dedicated to the PLC. Otherwise, it can cause disorder or malfunction of PLC
• LSIS Europe B.V., Netherlands
Tel: +31 (0)20 654 1420 Fax: +31(0)20 654 1429 e-mail: [email protected] PLC Others PLC Others PLC Others

• Homepage: http://www.lsis.com
A) Best B) Good C) Bad
► Connect expansion connector correctly when expansion module is needed.
► Do not detach PCB from the case of the module and do not modify the module.
LS constantly endeavors to improve our products so that information in this ► Turn off power when attaching or detaching module.
datasheet is subject to change without notice. ► Cellular phone or walkie-talkie should be farther than 30cm from the PLC.
The date of issue: 2013. 11 ► Input signal and communication line should be farther than 10cm from a high-
10310000448 Ver 3.2 tension and a power line in order not to be affected by noise and magnetic field.

5. Parts Name and Descriptions


(1) GPL-D22C/TR2B/TR2C 6. Specification of Input/Output Module (3) GPL-RY2C 8. Dimension (㎜)
(1) GPL-D22C/D24C/DT4B/DT4C(Input) Specification GPL-RY2C (1) GPL-D22C/TR2B/TR2C
Number of output points 16 points
Specifications GPL-D22C GPL-D24C GPL-DT4B/C
Rated load voltage/current DC24V/AC220V, 2A(Cosϕ=1)/point 5A/COM
Number of input points 16 points 32 points 16 points
Minimum load voltage/current DC 5V/1mA
Rated Input B 7 mA
Minimum load voltage/
Current C/C1 5 mA AC 250V DC 110V, 1,200 times/hour
Maximum switching frequency
Operating Voltage Range DC 20.4~28.8V(ripple: less than 5%) OFF → ON 10ms or less
Response
ON Voltage DC 19V or less Time ON → OFF 12ms or less
OFF Voltage DC 6V or less Mechanical 20 million times or more
Response OFF → ON 0~3ms or less
Rated load voltage/current 100,000 times or more
Time ON → OFF 0~3ms or less AC 200V/1.5A,AC 240V/1A(Cosϕ=0.7) 100,000 times
Common Terminal 16 points/COM or more
Operating indicator LED turns on at ON state of input Service
Life Electrical AC 200V/1A,AC 240V/0.5A(Cosϕ=0.35) 100,000
External connections Terminal block connector(M3 × 6 screws) times
Insulation Method Photo Coupler or more
(2) GPL-D24C/DT4B/DT4C/TR4B/TR4C/RY2C
DC 24V/1A,DC 100V/0.1A(L/R=7ms) 100,000 times
(a) External Connection or more
Common Method 8 points/COM
<GPL-D22C> <GPL-D24C> <GPL-DT4B/C> Operating Indicator LED turns on at ON state of output
External connections Terminal block connector(M3 × 6 screws)
- +
- + (a) External Connection
- +
15
COM1
+ - (2) GPL-D24C/TR4B/TR4C/DT4B/DT4C/RY2C
+ - COM
+ - COM1
31 14
COM 30 13
15 12 + - L L L L L L L L
14 11
13 19 10
12 18 09
DC DC
11 17 08
24V 24G
01 02 COMA 05 06 COMA COMA 09 10 COMC 13 14 COMC COMC
10 16 07
09 COM0 + - 06 FG 00 COMA 03 04 COMA 07 COMB 08 COMC 11 12 COMC 15 COMD
08 15 - + 05
04
07
06 03
Connector for connecting with 05 04 02 L L L L L L L L
 Connector 04 03 01
communication module 03 02 00
9-PIN Plug 9-pin female connector for Pnet 02 01
01 00
DC
00 - 24G
* Internally, The COMA and COMC are wired each other.
- DC
24G + DC
FG
-
DC
24G
 Part name display section FG FG
Display the Part name of Smart I/O + DC 24V
+ DC
24V 24V
GPL-D22C DC Input 16 7. Precaution on installation
GPL-D24C DC Input 32
GPL-DT4B/DT4C DC Input 16//TR Output 16 (1) When setting up the network, be sure not to duplicate the station number.
GPL-TR2B/TR2C TR Output 16 (2) GPL-TR2B/TR4B/DT4B/TR2C/TR4C/DT4C(Output) If there is any duplicated station number, the communication will not be established.
GPL-TR4B/TR4C TR Output 32 Specifications GPL-TR2B/C GPL-TR4B/C GPL-DT4B/C (2) Use cable complied with specification of this data sheet. Otherwise, it can cause serious
GPL-RY2C RELAY Output 16 Number of output points 16 points 32 points 16 points communication error.
Rated load voltage DC 24V
9. Warranty
(3) Make sure that communication cable connector fastened firmly. Otherwise, it can cause
Max. load current 0.5A/point, 3A/COM (1) Warranty period
Display the status of communication serious communication error.
 Communication LED OFF leakage current 0.1mA or less LSIS provides an 18-month-warranty from the date of the production.
module (4) Improper cable connection (snarled cable, redundant connection, etc) can cause
RUN Display the status of power Max. inrush current 4A /10ms or less (2) Warranty conditions
Maximum voltage drop communication error.
Displays the communication status of DC 1.0V or less For troubles within the warranty period, LSIS will replace the entire PLC or
RDY at ON circuit (5) Do not place communication cable near power cable or inductive noise source.
Comm. Module repair the troubled parts free of charge except the following cases.
Displays the abnormal err of comm.. External Voltage DC 24V ± 10%(ripple voltage : 4Vp-p or less) (6) Change of station number will not take effect before power is re-applied.
ERR (a) The troubles caused by improper condition, environment or treatment
module Power supply Current 30mA(TYP. All points On)
Response OFF → ON 1ms or less except the instructions of LSIS.
Time ON → OFF 1ms or less (b) The troubles caused by external devices.
 Station Switch 0 ~ 99 (0:Reserved) Common Method 16 points/COM (c) The troubles caused by remodeling or repairing based on the user’s own
×10 Set 10 digit of station number Operating Indicator LED turns on at ON state of output discretion.
×1 Set 1 digit of station number External connections Terminal block connector (M3 × 6 screws) (d) The troubles caused by improper usage of the product.
Insulation method Photo coupler (e) The troubles caused by the reason which exceeded the expectation from
 LED display section Display the ON/OFF status of module science and technology level when LSIS manufactured the product.
LED(0~15, 0~31) Display the ON/OFF status of module (f) The troubles caused by natural disaster.
(a) External Connection
(3) This warranty is limited to the PLC itself only. It is not valid for the whole system
 HOOK HOOK <GPL-TR2B/C> <GPL-TR4B/C> <GPL-DT4B/C> which the PLC is attached to.
HOOK Hook for mounting on DIN Rail
COM1
15

 Screwing Part 0V
Screwing Torque
0V + - COM1
Terminal block Screw tightening 3.7 kgf above 0V
+ -
+ - COM 31 L
COM0
L 30
screw Screw loosening 3.7 kgf above COM
L 15
L 15
14 L
14 L
L 13
L 13 19 L
Terminal Block In/Output terminal & Power input 12 L L 18
12 L
L 11
0 ~ 15 Input terminal(GPL-D22C) L 11 17 L
10 L
10 L L 16
0 ~ 31 Input terminal(GPL-D24C) L 09 COM0 + - L 09
08 L
GPL-D22C COM Common(16 points/COM)( GPL-D22C) 08 L L 15
L 07
L 07
/ COM0/COM1 Common(16 points/COM)( GPL-D24C) 06 L
06 L
GPL-D24C FG Frame Ground L 05
L 05 04 L
04 L
DC 24V +24VDC Input terminal 04 L L 03
L 03
L 03 02 L
DC 24G -24VDC Input terminal 02 L
02 L L 01
L 01
0 ~ 15/0 ~ 15 Input/Output terminal L 01 00 L
DC 00 L
COM0/COM1 Common(16 points/COM)
00 L - 24G
- DC
GPL-DT4B - DC
24G +
FG 24G
FG
/ FG Frame Ground + DC
FG
DC
24V + DC
24V
GPL-DT4C DC 24V +24VDC Input terminal 24V

DC 24G -24VDC Input terminal


0 ~ 15 Output terminal(GPL-TR2B/TR2C)
0 ~ 31 Output terminal(GPL-TR4B/TR4C)
GPL-TR2B/C COM Common(16 points/COM) (GPL-TR2B/C)
/ COM0/COM1 Common(16 points/COM) (GPL-TR4B/C)
GPL-TR4B/C FG Frame Ground
24V +24VDC Input terminal
24G -24VDC Input terminal
0 ~ 15 Output terminals
COMA~COMD Common(8 points/COM)
GPL-RY2C FG Frame Ground
DC 24V +24VDC Input terminal
DC 24G -24VDC Input terminal