0% found this document useful (0 votes)
78 views

Dokumen - Tips - RZ Error Code

The document lists various error codes and descriptions that can occur in a printing machine. There are over 70 different error codes grouped into categories from A to E relating to issues like sensors, paper feeding, ink levels and drum/master operations. The errors range from component failures to paper jams to low supplies.

Uploaded by

wasanaduplo
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
78 views

Dokumen - Tips - RZ Error Code

The document lists various error codes and descriptions that can occur in a printing machine. There are over 70 different error codes grouped into categories from A to E relating to issues like sensors, paper feeding, ink levels and drum/master operations. The errors range from component failures to paper jams to low supplies.

Uploaded by

wasanaduplo
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

5/19/2018 RZError Code-slidepdf.

com

Error Error
Description
Type Point
Master-positioning sensor does not go ON even after the write pulse motor is activated
A01 201
during the master-positioning, master-cut, ormaster-loading operation.
Master-positioning sensor does not go OFF even when the write pulse motor is reversed
A01 202
during the master-positioning or at start ofmaster-making operation.
A01 206 Timeout error during master-making operation

A01 211 Master-positioning sensor is ON during standby.


A01 214 Master-positioning sensor is ON at the start of master making.
A01 215 Faulty gate-array control for the write pulse motor (motor does not stop within set time)
Master-loading sensor was OFF when the master was checked at a specified drum angle
A02 509
during the master-loading oper201ation.
A04 303 Master-disposal jam sensor was OFF at both 120 and 180 degrees drum angle.
A04 314 Master-disposal error (recovery error).
A05 304 Master-disposal jam sensor was ON at the completion of the master-disposal operation.
A05 312 The master-disposal jam sensor was ON at the start of master-making operation.
The master-disposal jam sensor was ON when the master disposal box was set in the
A05 315
machine.
A06 403 Paper-feed-tray upper or lower safety switch is OFF.
Paper-ejection sensor was OFF when the paper should have arrived, and the paper sensor
A07 409
was ON when the machine stopped (Papermisfeed).
Paper sensor was OFF three times in succession when a paper misfeed was detected
A07 412
(paper misfeed).
Paper sensor was ON when the paper should have left the paper sensor (long-length paper
A07 413
mode error).
The paper sensor was ON at the start of machine operation when the START button was
A07 418
pressed.
A07 429 Paper feed error (recovery error).
Paper sensor was ON when the machine went into paper feed retry movement after a paper
A07 432 misfeed.
Paper-ejection sensor was OFF when paper should have arrived, and the paper sensor was
A08 410
OFF when the machine stopped (paper jamon the print drum).
Paper sensor was ON when the paper should have left the paper sensor during feeding of
A08 421
long paper in long-length paper mode (paperlonger than 555 mm).
A08 430 Paper jam on print drum (recovery error).
A09 411 Paper-ejection sensor was ON when the paper should have left the paper-ejection sensor.
Paper-ejection sensor was ON at the start of machine operation when the START button
A09 417
was pressed.
A09 431 Paper-ejection error (recovery error).
A10 102 Original-registration-sensor remaining jam
A10 103 Original-IN-sensor remaining jam
A10 105 Original-registration-sensor non-arrival jam
A10 106 Original-IN-sensor non-arrival jam
A10 107 Original-OUT-sensor non-arrival jam
A10 109 An original feed error occurred, due to opening the AF.
A10 162 No original in AF during AF master making.
A16 525 Waiting for the master to be removed.
A17 209 Cutter home-position switch is OFF at the start of master-making or master-set operation.
A34 218 Request to resetting the master.

http://slidepdf.com/reader/full/rz-error-code 1/7
5/19/2018 RZError Code-slidepdf.com

B01 730 Keycard counter: No card


With the “Tape separation” function set ON, no power is supplied to the job separator when
B22 721
start key is pressed.
After cluster-A signal turned ON, BUSY-signal stayed "L" more than 7 seconds (power to job
B22 727
separator was turned OFF while the tape isbeing ejected.
With the “Tape separation” function set ON, no tape detected in the job separator when the
B23 722
start key is pressed.
B23 723 No tape remains in job separator upon completion of the tape-ejection operation.

B24 724 Tape jam detected when the start key is pressed with the “Tape separation” function set to
ON.
Job separator tape-jam detection signal is “H” within 1,200 milliseconds after the cluster-A
B24 725
signal turns ON (tape misfeed).
Job separator tape-jam detection signal is “L” when the BUSY signal changes from “L” to “H”
B24 726
(or after 7 sec. at “L”) after the cluster -Asignal goes ON (tape misfeed).
B31 916 Network cable is not connected when the machine is powered ON.
B32 917 Communication error on the network.
Error detected by Network Interface Card (NIC) - NAK (negative acknowledgement was
B32 920
received).
B33 931 DHCP server is not found with DHCP ON.

B34 919 Error detected on the locally connected printer.


C01 512 The ink sensor did not go ON even when inking was performed for the preset period.
C01 563 Ink remaining amount is zero.
C01 574 Inkless error was detected 5 times consecutively on one same ink bottle.
The master end was detected twice in succession at 10-milliseconds intervals during master
C02 200
transport.
C02 240 Master remaining amount is zero
Compression detection position was reached before the master-compression-motor
C03 308 encoder-sensor count reached the specified level,after the master compression motor
turned ON in the compression direction.
C03 313 Master removal box full detected by the master removal count.

C04 402 Paper detection sensor is OFF (no paper on the feed tray).
Print drum is not set in the machine (drum connection signal, drum safety switch, and drum-
D01 526
lock sensor is OFF.
D01 527 Print drum connection signal is OFF when the print drum was inserted in the machine.
D01 528 Print drum safety switch is OFF when the print drum was inserted in the machine.
Print drum lock sensor is OFF when the print drum was inserted in the machine (time-out: 5
D01 529
seconds).
Print drum connection signal does not go OFF within 5 seconds after the print drum safety
D01 530
switch went OFF when the print drum waspulled out.
D02 532 Incorrect print drum is used.
D03 533 Ink cartridge set sensor is OFF.
D04 534 Incorrect ink cartridge is used.
D04 560 Ink TAG is not detected on ink bottle.
Ink cartridge communication error (communication with the ink cartridge was interfered by
D04 561
noise).
D04 562 Wrong ink cartridge information.
D04 564 Detected a mismatch in ink cartridge information
D05 210 Master detection sensor is OFF (not detecting master).
D07 310 Disposal-box safety switch is OFF.
D08 224 Master making unit is not set (both the safety switch and lock sensor are OFF).

http://slidepdf.com/reader/full/rz-error-code 2/7
5/19/2018 RZError Code-slidepdf.com

D08 226 Master making unit safety switch is still OFF when the master making unit is set in position.
Master making unit lock sensor is still OFF when the master making unit is set in position
D08 227
(timeout: 5 seconds).
Master making unit lock sensor is still ON even after the master making unit safety switch
D08 228
went OFF, when the master making unit waspulled out of the machine.
D09 212 Master-making-unit set sensor is OFF (sensor light path is free).
D11 535 Front cover set switch is OFF.
D13 9 The rear cover is opened (serviceman safety switch is OFF).
D17 236 Incorrect master roll.
D17 237 Master roll undetected.
D17 238 Master roll communication error.
D17 239 Wrong master roll detected.
D17 241 Detected a mismatch in master roll information.
D18 522 Print drum ready for release (solenoid is ON).
D19 223 Master making unit ready for release (solenoid is ON).
D22 540 Error in access to the Drum PCB (unable to read from or write on the Drum PCB).
D22 542 Abnormal data on Drum PCB.
Battery voltage was less than 2.5 V when the power was switched ON (weak battery: time to
E01 10 replace battery).
Master counter reached the value set for the maintenance call (value set by test mode).
E02 11 [The message appears when either the power isturned ON, the unit is reset, or when the
machine operation ended.]
Copy counter reached the value set for the maintenance call (value by set test mode). [The
E02 12 message appears when either the power isturned ON, the unit is reset, or when the machine
operation ended.]
Maintenance counter inside the print drum reached the value set for the maintenance call
E02 22 (value set by test mode). [The messageappears when either the power is turned ON, the
unit is reset, or when the machine operation ended.]
F01 15 There is no master on the print drum at the start of printing.
F02 18 Paper size does not match with the image size on the print drum at the start of printing.
F03 16 Multi-up was selected using custom size paper.
F05 19 In master making, the print quantity selected is less than the minimum print quantity.
Paper size does not match with the size of image on the print drum when test print is
F10 21
selected and activated.
F21 32 Next original is not in placed on AF for multi-up operation.
F22 33 Next original is not placed on flatbed for multi-up operation.
F37 50 Original was set on the AF with book mode selected, when master making is activated.
F50 910 Auto-printer-selection is disabled due to error on linked printer.
F54 923 Auto-printer-selection is disabled due to no paper in the linked printer.
F55 924 Auto-printer-selection is disabled while receiving print data from PC.
F58 927 Cannot print from linked printer (Initializing NET-C).
H1 566 Requesting ink color information input (Ink-TAG related).
H2 567 Requesting print density information input (Ink-TAG related).
H3 568 Requesting test printing print density information input (Ink-TAG related).
H4 242 Requesting master-making density information input (Master-TAG related).
H5 243 Requesting Print density information input (Master-TAG related).
H6 244 Requesting test printing print density information input (Master-TAG related).
Main encoder sensor does not go ON/OFF within 10 milliseconds after the main motor
P01 520
activates.

http://slidepdf.com/reader/full/rz-error-code 3/7
5/19/2018 RZError Code-slidepdf.com

B-positioning sensor status does not change even after 3,033 pulses after the main motor
P01 521
activates.
Clamp unit is not at the home position while the print drum is in operation (except during
P01 524
master disposal).
P01 537 Print drum failed to stop at position B. (over-run)
P01 538 Print drum is not locked during operation. (Print-drum lock position sensor: OFF)
P02 400 Both the upper and lower limit sensors were ON at the same time.
P02 401 Overload current was detected in the elevator motor.
The lower-limit sensor does not go OFF within 2 seconds after the elevator motor operates
P02 404
in the raising direction from the lower-limitposition.
The upper-limit sensor does not go ON within 12 seconds after the elevator motor operates
P02 405
in the raising direction.
The upper-limit sensor does not go OFF within 2 seconds after the elevator motor operates
P02 406
in the lower direction from the upper-limitposition.
The lower-limit sensor does not go ON within 12 seconds after the elevator motor operates
P02 407
in the lowering direction.
The upper-limit sensor is OFF continuously for over 2 seconds during operation of the
P02 408
elevator servo action to raise the feed tray.
Clamp sensor A is OFF after the completion of the clamp unit initialization or home
P03 500
positioning movement.
Clamp sensor B does not change within 1 second from the time the clamp motor operates in
P03 501
the correct direction.
Clamp sensor B does not change within 1 second from the time the clamp motor operates in
P03 502
the reverse direction.
Clamp sensor A does not go ON within 3 seconds when the clamp unit makes initialization
P03 503
movement.
At the start of Clamp plate open/close action, the the detection sequence of clamp-sensors
P03 504
A & B is abnormal.
At the start of print drum Positon-A compensation movement, the detection sequence of
P03 505
clamp-sensors A & B is abnormal.
At the start of Clamp unit Home-positioning movement, the detection sequence of clamp-
P03 506
sensors A & B is abnormal.
P03 507 Clamp sensor A is ON after the clamp release action is completed.
P03 508 Clamp sensor A is ON after the A-position compensating movement is completed.
Clamp unit is not in the home position while the print drum is in movement (cause due to the
P03 545
clamp motor).
The overflow sensor was ON for a set number of times in succession during the 10-
P04 513
millisecond-interval overflow-sensor check.
The vertical-centering sensor does not switch ON even when the vertical-positioning pulse
P05 603 motor activated in the image-down direction for5 seconds during vertical home positioning
movement.
The vertical-centering sensor does not switch OFF even when the vertical-positioning pulse
P05 604 motor activated in the image-up direction for 5seconds during vertical home positioning
movement.
Even though the vertical positioning motor stopped according to the vertical centering
P05 605 sensor detection, the stopping position does notcorrespond with the programmed position.
(GA control error).
P05 612 The one-step-positioning key was pressed with vertical-print-position information undefined.
P08 951 Print job executed was not in correct RisoRinc format.
Print pressure HP sensor does not switch ON within 3.9 seconds after the print pressure
P11 600
pulse motor activated towards higher pressureduring home positioning operation.
Print pressure HP sensor does not switch OFF within 4.6 seconds after the print pressure
P11 601
pulse motor activated towards lower pressureduring home positioning operation.
P11 602 Even though the print pressure control pulse motor stopped according to the print pressure

http://slidepdf.com/reader/full/rz-error-code 4/7
5/19/2018 RZError Code-slidepdf.com

HP sensor detection, the stopping positiondoes not correspond with the programmed
position. (GA control error).
P12 301 Master compression motor lock when moving compression plate up.
Master compression sensor does not go ON within 6.5 seconds after the master
P12 305
compression motor operates in the return direction.
Master compression sensor does not go OFF within 2 seconds after the master
P12 306
compression motor operates in the compress direction.
Master compression plate maximum position is not detected within 6.5 seconds after the
P12 307
master compression motor operates in thecompress direction.
Master-compression-motor encoder sensor count did not change as the master
P12 309 compression motor activated in the compress directionand moved out from the home
position.
Master-compression-motor encoder sensor count did not change within 10 milliseconds
P12 316
after the master compression motor activated.
P12 300 Overload current was detected in the master removal motor.
P13 203 Cutter HP switch does not go OFF within 100 milliseconds after the cutter motor is activated.
P13 204 Cutter HP switch does not go ON within 300 milliseconds after the cutter motor is activated.
Master-positioning sensor is ON when the print drum rotates through the preset angle
P13 205
following master cutting.
P13 221 Both the cutter HP switch and cutter stop position switch are ON at the same time.
Cutter HP switch does not go ON within 450 milliseconds after the cutter home positioning
P13 222
operation started.
Cutter HP switch does not go OFF within 500 milliseconds after the cutter moved out from
P13 231
the home position.
Cutter stop position switch does not go ON within 2 seconds after the cutting operation
P13 232
started.
Cutter stop position switch does not go OFF within 500 milliseconds after the cutter
P13 233
activates to move from the stop position to the homeposition.
Cutter HP switch does not go ON within 2 seconds after the cutter home positioning
P13 234
operation started.
P14 114 Incorrect main-unit data.

P14 115 The scanner operation is not completed within the set time.
P14 116 Timeout error for black shading compensation. (RZ3 series only)
P14 117 Timeout error for white shading compensation. (RZ3 series only)
P14 123 Offset adjustment not completed within set time. (RZ3 series only)
P14 124 Gain adjustment not completed within set time. (RZ3 series only)
P14 125 Offset adjustment not completed.
P14 126 Gain adjustment not completed.
P14 135 Malfunction detected during offset adjustment. (RZ3 series only)
P14 136 Malfunction detected during offset adjustment. (RZ3 series only)
P14 137 Malfunction detected during black shading compensation. (RZ3 series only)
P14 138 Malfunction detected during white shading compensation. (RZ3 series only)
Even though the read pulse motor stopped according to the sensor detection, the stopping
P14 170
position does not correspond with theprogrammed position. (GA control error).
P15 4 Communication error with AF-CPU.
ABC (auto-base-control) timeout. The original does not move from the ABC scanning
P15 110
position on the AF unit.
P15 111 Operation command was made to the AF unit without 24 volts supplied to the AF unit.
Timeout error in receiving reply from the AF unit after command signal was sent from the
P15 130
Riso printer to the AF unit.
P15 131 Riso printer received an undefined command from the AF unit.

http://slidepdf.com/reader/full/rz-error-code 5/7
5/19/2018 RZError Code-slidepdf.com

P15 132 Riso printer detected communication sequence error from the AF unit.
P15 133 Communication error with AF unit (ACK or NAK error).
P15 134 Riso printer could not send command to the AF unit within the set time.
P15 160 AF unit detection signal went OFF while the AF unit is in operation.
P17 20 Solenoid counter is not connected.
Print drum lock sensor is still ON even after 100 milliseconds after the print drum lock
P18 531
solenoid is activated.

P19 207 TPH pressure


activates in thesensor does not go
decompressing OFF within
direction, 2 seconds
orduring after the thermal-pressure
home positioning operation. motor

TPH pressure sensor does not go ON within 2 seconds after the thermal-pressure motor
P19 208
activates in the decompressing direction.
TPH pressure sensor does not go OFF within 500 millisecond after the thermal-pressure
P19 216
motor activates in the compressing direction.
TPH pressure sensor does not go ON within 2 seconds after the thermal-pressure motor
P19 217
activates in the compressing direction.
Paper-ejection-wing home sensor does not go OFF within 7,000 milliseconds after the paper
P20 415
ejection wing motor activates in thecounterclockwise direction from the home position.
P20 416 Overload current was detected in the paper-ejection motor.
Paper-ejection encoder sensor status does not change within 10 milliseconds after the
P20 437
paper-ejection motor is activated.
Inking-motor encoder sensor status does not change within 20 milliseconds after the inking-
P24 539
motor is activated.
P25 26 Battery voltage was below 2.3 volts (too low) when the power is turned ON.
EEPROM on the print drum PCB was being accessed while the print drum was in releasing
P92 570
action from the machine.
No reply from the NET-C network interface card while accessing to the network interface
P93 932
card.
P93 933 No response from NET-C for 90 seconds during NET-C initialization.
TPH code does not match with the machine code when the power is turned ON with the
P94 225 master-making unit in operating position or whenthe master-making unit is inserted in
operating position while the power is ON.
Machine serial-number information sent from SH-PCB does not match with the machine
P95 59
serial number information in the MCTL PCB.
P96 171 TPH resistance value not input.
P96 172 Scanner adjustment not completed.
P96 433 Paper size width potentiometer test-mode setting is not completed.
P96 569 Either the print drum color information or ink category information is still not input.
P96 613 Print pressure data missing.
No reply from Mini-Rosa PCB when the machine power is turned ON even though the Rosa
P98 2
connection signal is ON.
P98 5 Hardware error.

P98 6 FRAM checksum error.


P98 7 Mini Rosa PCB not connected.
P98 38 Machine data on EEPROM does not match with that on the SH-PCB
P98 39 Improper EEPROM on the SH-PCB.
P98 46 The DIMM capacity does not match.
P98 51 Touch-panel communication error
P98 53 Failure in calling out the saved Memory settings (program, mode, user paper information).
P98 54 Failure in saving the Memory settings (program, mode, user paper information).
Machine type code from SH-PCB does not match with the machine information on the H8-
P98 55
PCB.

http://slidepdf.com/reader/full/rz-error-code 6/7
5/19/2018 RZError Code-slidepdf.com

P98 63 The test-mode memory data stored was outside the adjustment range.
P98 64 An undefined command was sent in communication between SH-PCB and MCTL PCB.
P98 65 Communication error 01 between SH-PCB and MCTL PCB (MCTL PCB side).
P98 67 Communication error 03 between SH-PCB and MCTL PCB (MCTL PCB side).
P98 68 Communication error 04 between SH-PCB and MCTL PCB (MCTL PCB side).
P98 69 Communication error 05 between SH-PCB and MCTL PCB (MCTL PCB side).
P98 70 Communication error 06 between SH-PCB and MCTL PCB (MCTL PCB side).

P98 71 Communication error 07 between SH-PCB and MCTL PCB (MCTL PCB side).
P98 72 Communication error 08 between SH-PCB and MCTL PCB (MCTL PCB side).
P98 73 Communication error 09 between SH-PCB and MCTL PCB (MCTL PCB side).
P98 74 Communication error 10 between SH-PCB and MCTL PCB (SH-PCB side)
P98 75 Communication error 11 between SH-PCB and MCTL PCB (SH-PCB side)
P98 76 Communication error 12 between SH-PCB and MCTL PCB (SH-PCB side)
P98 77 Communication error 13 between SH-PCB and MCTL PCB (SH-PCB side)
P98 78 Communication error 14 between SH-PCB and MCTL PCB (SH-PCB side)
P98 79 Communication error 15 between SH-PCB and MCTL PCB (SH-PCB side)
P98 80 Communication error 16 between SH-PCB and MCTL PCB (SH-PCB side)
P98 81 Communication error 17 between SH-PCB and MCTL PCB (SH-PCB side)
P98 82 Communication error 18 between SH-PCB and MCTL PCB (SH-PCB side)
P98 83 Communication error 19 between SH-PCB and MCTL PCB (SH-PCB side)
P98 84 Communication error 20 between SH-PCB and MCTL PCB (SH-PCB side)
Machine serial number information on the SH-PCB EEPROM does not match with that in
P98 98
the FRAM.
P98 119 Image processing PCB trouble.
P98 120 Scanner communication problem. (RZ3 series only)
P98 129 Faulty Scanner GA PCB. (RZ3 series only)
P98 245 Master transfer time-out error during master making (Write pulse motor error).

P98 246 Master transfer time-out error during master making (Load pulse motor error).
P98 614 Vertical print position data missing.
P98 934 Main read/write communication error (detected by read/write side).
P98 935 Main read/write communication error (detected by machine side).
P98 937 Serial number data missing.
P98 938 FRAM version-down.
P98 947 24V-A does not go ON (a possible burnt 24-volt group-A fuse).
P98 948 24V-B does not go ON (a possible burnt 24-volt group-B fuse).
P98 949 24V-A does not go OFF.
P98 950 24V-B does not fo OFF.
P98 952 Checksum error on the ROSA flash-memory.
P98 953 Unsuccessful writing on the ROSA flash-memory.
P99 936 Software error

http://slidepdf.com/reader/full/rz-error-code 7/7