0% found this document useful (0 votes)
41 views2 pages

Start AST D100 886369

This document provides technical specifications for the Flygt AST automatic starters for controlling pumps. It lists the starter models, their power and current ratings, dimensions, and part numbers. Features include direct-on-line starting, overload protection, and monitoring of thermal contacts.

Uploaded by

nsebxx
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
41 views2 pages

Start AST D100 886369

This document provides technical specifications for the Flygt AST automatic starters for controlling pumps. It lists the starter models, their power and current ratings, dimensions, and part numbers. Features include direct-on-line starting, overload protection, and monitoring of thermal contacts.

Uploaded by

nsebxx
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Flygt AST

Automatic starter, direct-on-line, 25 A – 100 A

Technical data
3-phase starter for the manual operation of one pump or automatic duty with the ENM-10 level regulator.
It includes a main supply switch and a motor protection breaker. There is also a monitoring function for
pumps with built-in thermal contacts. Cable glands are standard and terminal blocks provide simple and
secure installation.

Voltage 3P+PE; 230 V, 380 V – 400 V 1


Frequency 50 Hz – 60 Hz
Power range 15 kW – 55 kW (rated power at 400 V)
Current range 25 A – 100 A
Starting method Direct-on-line starting
Overload protection Thermal/magnetic overload protection
Monitoring Monitoring of thermal contacts with manual reset
Level control Terminal inputs for separate start and stop level regulators connected
to 24 VAC
Control circuit 24 VAC, separately fused
Door-mounted components Main switch
Hand-Off-Auto selector switch
Run and failure indication
Reset overtemperature
Material 1.2 mm steel plate
Colour Grey (RAL 7032)
Degree of protection IP55
Size 400 mm x 300 mm x 210 mm (15 kW – 25 kW)
500 mm x 400mm x 260 mm (30 kW – 55kW)
Weight 11.5 kg (15 kW – 25 kW)
23.5 kg (30 kW – 55kW)
Approvals CE
1
The starters are reconnectable for 230 V or 400 V systems. The standard connection at delivery is
400 V.

Type Rated Current Supply cable Pump cable Options Part number
power range (A) ∅ (mm) Ø (mm)
(kW)
AST-15N-D32-400-56 15 25 – 32 18 – 25 22 – 32 554 27 00
AST-20N-D40-400-56 20 28 – 40 18 – 25 22 – 32 554 27 01
AST-25N-D50-400-56 25 40 – 50 22 – 32 22 – 32 554 27 02
AST-30N-D63-400-56 30 45 – 63 22 – 32 30 – 38 – 554 27 03
AST-40N-D75-400-56 40 57 – 75 22 – 32 30 – 38 554 27 04
AST-45N-D90-400-56 45 70 – 90 22 – 32 30 – 38 554 27 05
AST-55N-D100-400-56 55 80 – 100 32 - 38 34 – 44 554 27 06
AST-15N-D32-400-5-AH 15 25 – 32 18 – 25 22 – 32 554 27 10
AST-20N-D40-400-5-AH 20 28 – 40 18 – 25 22 – 32 554 27 11
AST-25N-D50-400-5-AH 25 40 – 50 22 – 32 22 – 32 Ammeter and 554 27 12
AST-30N-D63-400-5-AH 30 45 – 63 22 – 32 30 – 38 hour counter, 554 27 13
AST-40N-D75-400-5-AH 40 57 – 75 22 – 32 30 – 38 50 Hz 554 27 14
AST-45N-D90-400-5-AH 45 70 – 90 22 – 32 30 – 38 554 27 15
AST-55N-D100-400-5-AH 55 80 – 100 32 – 38 34 – 44 554 27 16
AST-15N-D32-400-6-AH 15 25 – 32 18 – 25 22 – 32 554 27 20
AST-20N-D40-400-6-AH 20 28 – 40 18 – 25 22 – 32 554 27 21
AST-25N-D50-400-6-AH 25 40 – 50 22 – 32 22 – 32 Ammeter and 554 27 22
AST-30N-D63-400-6-AH 30 45 – 63 22 – 32 30 – 38 hour counter, 554 27 23
AST-40N-D75-400-6-AH 40 57 – 75 22 – 32 30 – 38 60 Hz 554 27 24
AST-45N-D90-400-6-AH 45 70 – 90 22 – 32 30 – 38 554 27 25
AST-55N-D100-400-6-AH 55 80 – 100 32 – 38 34 – 44 554 27 26

886369 / 7.0
Product Sheet
Xylem Water Solutions Global Services AB
361 80 Emmaboda, Sweden
Tel. +46-471-24 70 00, Fax +46-471-24 74 0
www.xyleminc.com

Flygt is a trademark of Xylem Inc. or one of its subsidiaries.


© 2016 Xylem, Inc. 886369 June 2016