0% found this document useful (0 votes)
66 views

2023-15 LOA Network

This document is a letter of acceptance from the Sr DSTE of Raipur Division-S and T of South East Central Railway to M/s Chhattisgarh IT Solutions-Raipur for the execution of signaling and telecommunication work. The total accepted cost of the work is Rs. 18526967.38. The contractor must submit a performance guarantee of 5% of the contract value within 21 days.

Uploaded by

sr.vijay.pandey
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
66 views

2023-15 LOA Network

This document is a letter of acceptance from the Sr DSTE of Raipur Division-S and T of South East Central Railway to M/s Chhattisgarh IT Solutions-Raipur for the execution of signaling and telecommunication work. The total accepted cost of the work is Rs. 18526967.38. The contractor must submit a performance guarantee of 5% of the contract value within 21 days.

Uploaded by

sr.vijay.pandey
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 11

3/1/24, 10:37 AM ireps.gov.in/epsn/works/tds/publishLOAWorksLetter.do?

Action=ViewPublishedLetter&nitOId=73034598&tdId=1921130&letterI…

SOUTH EAST CENTRAL


RLY
RAIPUR DIVISION-S
AND T
Office of the
Sr DSTE, 1st
Floor,
DRM Complex, S.E.C.
Railway
Raipur, 492008
Chhattisgarh, India

Letter No: RAIPUR DIVISION-S AND T / SNT-


R- 2023-15 / 01527360098725 Dated: 01/03/2024

M/s CHHATTISGARH IT SOLUTIONS-


RAIPUR
RING ROAD NO. 1
DAU HIRALAL VYAVSAIK PARISAR
TATIBANDH
RAIPUR- 492001
Chhattisgarh, India

Sub: Letter Of Acceptance

Ref: 1. Tender No. SNT-R-2023-15 closing date 09-02-2024


15:00 for Execution of Signaling & Telecommunication
work in connection with: (1) [Balance Work] Expansion
of Computer Based Training Cum Exam Centre, Bhilai,
(2) Replacement of overage core network equipment of
Railnet at DRM complex, (3) [Balance Work] Setup of
store in 2nd floor and provision of two room with
verandah on 2nd floor & renovation of existing of store
of Gati Shakti Unit office in DRM Office Complex at
Raipur, (4) Upgradation of Exchange Yard, Bhilai.
2.
Your bid ID 16308143 dated 09/02/2024 14:27
3.
Your Negotiation bid IDs [ 16368216 dated
24/02/2024 12:50 ]

The Competent Authority has accepted your offered rates in


connection with the subject work. The total cost of the work at the
accepted rates works out to Rs. 18526967.38 (Rupees One Crore
Eighty-Five Lakh Twenty-Six Thousand Nine Hundred And Sixty-
Seven Rupees And Thirty-Eight Paise Only)

A sum of Rs.233800 deposited as Earnest Money vide IREPS


reference ID PE681621290719 has been retained towards initial
Security Money for due and faithful fulfillment of the contract, and the
balance Security Money will be recovered from the progressive bills @
6 % of the bill amount till it reaches 5 % of the contract value in terms
of clause 16(1) of IRGCC 2022.

You are requested to submit Performance Guarantee in the form as


given in Clause 16(4) of IRGCC 2022 equivalent to 5 % of the contract
value amounting to Rs. 926348.37 (Rupees Nine Lakh Twenty-Six
Thousand Three Hundred And Fourty-Eight Rupees And Thirty-Seven
Paise Only) within 21 days from the date of issue of Letter of
Acceptance, valid up to stipulated date of completion plus 60 days so
that contract agreement can be executed. However, a penal interest of
https://www.ireps.gov.in/epsn/works/tds/publishLOAWorksLetter.do?Action=ViewPublishedLetter&nitOId=73034598&tdId=1921130&letterId=896… 1/11
3/1/24, 10:37 AM ireps.gov.in/epsn/works/tds/publishLOAWorksLetter.do?Action=ViewPublishedLetter&nitOId=73034598&tdId=1921130&letterI…
12% per annum shall becharged for thedelay beyond 21(Twenty

https://www.ireps.gov.in/epsn/works/tds/publishLOAWorksLetter.do?Action=ViewPublishedLetter&nitOId=73034598&tdId=1921130&letterId=896… 2/11
3/1/24, 10:37 AM ireps.gov.in/epsn/works/tds/publishLOAWorksLetter.do?Action=ViewPublishedLetter&nitOId=73034598&tdId=1921130&letterI…
one)days, i.e., from 22nd day after the dateof issueof LOA. In case the
contractor fails to submit the requisite PG even after60days from the
date of issue of LOA, the contract liable to be terminated. Incase
contract is terminated railway shall be entitled to forfeit EMD and
other dues payable against that contract. The failed contractor shall be
debarred from participating in re-tender for that work.

The entire work shall be completed within 8 month from the date
of issue of Letter of Acceptance.

1: Tender documents as signed by you shall be taken to mean as part


and parcel of the agreement

2: Until a formal agreement is signed, this letter of acceptance will


constitute a binding contract between you and Railways.

3: The Rates accepted are inclusive of all lead, lift, royalty, GST and all
other Taxes/charges leviable by Central/State Government and local
bodies.

4: All payments will be passed as per extant works contract.procedure


and agreement..

5: Reference to conditions :- M/s CHHATTISGARH IT SOLUTIONS-


RAIPUR has not offered /quoted any conditions in this tender.

6: Please contact Divisional Signal &Telecommunication


Engineer/S.E.C.Railway/Raipur and SSE/Tele/Raipur immediately for
further instructions to start the work on the authority of this letter of
acceptance.Materials to be supplied by the contractor against this work
are to be supplied to SSE/Tele/Raipur at his depot.

7: Please obtain the license from the Assistant


LabourCommissioner,Raipurasrequired under contract
Labour(Regulation & Labour act)1970 and producethesame to
thisoffice if casual Labour engaging andif applicable

8: The accepted rates of Schedule-B are not to be used as LARs in


futuretenders.

9: Please acknowledge the receipt of this letter of acceptance.

All Other terms and conditions, as stipulated in the tender


documents shall be applicable.

KUMAR CHANCHAL PRIYDARSHI


DSTER
Digitally Signed
View Signature Details

Awarded Quantities And Rates

Item Item Desc Item Item Qty Unit Escl. Advt.Value Bid Rate/ Bid Amount
Sno. Code Qty Unit Rate(Rs) (%) (Rs) Unit Rate (Rs)
Schedule A-Execution of Items (Item Directory - Not %
Applicable) Above
Execution of
1 View Details At Par
Items

https://www.ireps.gov.in/epsn/works/tds/publishLOAWorksLetter.do?Action=ViewPublishedLetter&nitOId=73034598&tdId=1921130&letterId=896… 3/11
3/1/24, 10:37 AM ireps.gov.in/epsn/works/tds/publishLOAWorksLetter.do?Action=ViewPublishedLetter&nitOId=73034598&tdId=1921130&letterI…

Schedule Totals
Schedule B-Supply of Items (Item Directory - Not %
Applicable) Above
1 Supply of Items View Details At Par
Schedule Totals
Total Value
Rebate on Total Value
(%)
Net Bid Value

Item Breakup
Schedule A-Execution of Items
Item - 1 Execution of Items
Item
S No. Description of Item Unit Qty Rate Amount
No

Transportation, fixing & commissioning of


1 01 wall mounting rack (9U) as per instruction Numbers 6
of site in charge.

Concealed wiring of cat-6 cable/telephone


cable/ OFC cable in the PVC pipe/PVC
channel by making groove in the wall,
fixing the PVC pipe with clamps, nails and
plastering and distempering to make it as
it was earlier as per instructions of
engineer-in-charge. This includes laying
and fixing of all the PVC pipes as per
colour in systematic way as per instruction
of Rly. Engg. at site. required for laying of
all types of cables for railnet, telephone
2 02 connection etc., All the sundry items for Metre 564.7
the work has to be supplied by the
contractor. Railways will supply telephone
cables/Cat-6 cables and PVC
pipe/channels. All the telecom cables will
be drawn from the specified location ,
approved drawing. The payment would be
made as per layout of grove made in the
wall, irrespective of how many pipe
(maximum three pipes) are laid and how
many cables drawn through these pipes.

Fixing of PVC pipes on wall,


bridges,platforms etc complete with U
clamps & other necessary fixture,screw
3 03 Metre 550
etc. This includes supply &fixing of t and
other bends flexible PVC pipes -25mm etc
as required.

Laying/Drawl of data cable/communication


cable/power cable/OFC /other cable
4 04 through PVC pipe /casing & capping as per Metre 4350
site requirement and instructions of site in
charge.

Splicing/termination of OFC Pigtail/patch


cord as per instruction of site in charge.
5 05 Necessary arrangement including Splicing Numbers 208
machine required for splicing shall be
arranged by Contractor.

Installation, Fitting, testing &


6 06 commissioning charges for CCTV as per Job 1
instruction of railway representative.

7 07 Transportation, installation, Job 1


configuration, migration and
commissioning of Core
https://www.ireps.gov.in/epsn/works/tds/publishLOAWorksLetter.do?Action=ViewPublishedLetter&nitOId=73034598&tdId=1921130&letterId=896… 4/11
3/1/24, 10:37 AM ireps.gov.in/epsn/works/tds/publishLOAWorksLetter.do?Action=ViewPublishedLetter&nitOId=73034598&tdId=1921130&letterI…
Switch.

Transportation, installation,
8 08 configuration, migration and Job 1
commissioning of High end Server.

Excavation of trench Depth 1.0 Mtr. &


width 0.3 Mtr and clearing of roots of
trees, bushes, ballast and reconditioning
9 09 Kilometre 0.2
etc., including bailing out water and
disposal of extra soil in all soils including
soft rocky area.

Laying of Signalling Cable/Power/Quad


cable / PIJF cable in the excavated trench
to Drg.No:CON/SK/T/5.Transportation,
supply of 'U' clamps and anchoring of
cable at every 10 Mtrs with 'U' clamp to
Drg.No:CSTE/C/Cable/81 including back
filling with excavated earth and ramming
10 10 Kilometre 0.2
of trenches after cable laying. Note: The
contractor has to conduct detailed site
survey of the cable route, prepare a plan
to get approval of the Railway, putting
white lime powder marking before
excavation of earth under supervision of
railways authorised representative.

Transportation including
loading/unloading of HDPE pipe from the
stores of SSE
(SIG/Tele)/BIA/R/BYT/DRZ to work site,
laying of the same (with 4 mm nylon rope
11 11 pre inserted inside the HDPE pipe) in Kilometre 0.2
excavated trench/already laid GI/RCC
pipes/tubes, jointing,levelling and end
sealing the pipes. HDPE pipe, couplers and
end caps shall be supplied by Railway.
Nylon rope and other required materials
shall be supplied by the Contractor.
Transportation, loading/unloading of OFC
from the stores of railway to the work site
with care, pushing/pulling OFC through the
HDPE pipes, sealing of the duct by sealling
/caps plugs. The cable is to be laid by
mechanised means. At inaccessible places
where mechanised laying is not possible,
the cable is to be laid manually by pulling
12 12 through pre inserted rope. This also Kilometre 0.2
includes testing of cable drums in the store
premises before transportation and
submissions of results thereof. Empty
cable drums to be returned by the
contractor. The cable drums with unused
cable at site to be returned by the
contractor to the stores depot of
Consignee.

Fixing of concrete cable route marker at


30-40 meter and at diversion point
including supply & transportation of cable
13 13 Numbers 6
route marker at site. Detail size & fixing of
cable route marker should be followed as
per drawing no. SDO/Cable laying/020.

Installation, cable termination, testing and


14 14 Numbers 4
commissioning of 10/20/50 Pair CT Boxes.

15 15 Transportation, installation of Optical Fibre Numbers 5


termination box and splicing of Optic Fibre
Cable (24 fibre) inside the termination box
with provision of taking out fibre of OFC as
required. This includes supply of

https://www.ireps.gov.in/epsn/works/tds/publishLOAWorksLetter.do?Action=ViewPublishedLetter&nitOId=73034598&tdId=1921130&letterId=896… 5/11
3/1/24, 10:37 AM ireps.gov.in/epsn/works/tds/publishLOAWorksLetter.do?Action=ViewPublishedLetter&nitOId=73034598&tdId=1921130&letterI…
installation accesories (as required) as
detailed in technical specification and
advised by Railway's Engineer-at-
site.This also includes End to End testing
of all fibres of the optical fibre cable
terminated between cable hut to cable
hut of each station.

Excavation of trenches including clearing


of roots of trees etc. in hard rocky soil by
chiseling up to a depth of 0.5m to 0.8
Mtr.
At the bottom, supply and placing half
round RCC pipe on sieved soil of 30 mm
over cable and concreting throughout the
lenght upto a layerof 75 mm
approximately (1:2:4) , as advised by the
16 16 site engineer & Guide lines on Signalling Metre 50
cable Laying issued by Signal Directorate
Research,Design & Standards organisation
Ministry of Railways Manak Nagar
Lucknow- 226011,Version-1.0, Effective
from dt 31.10.2011 . Then digging and
backfilling the trench by digging and
carrying earth from a lead of maximum
30Mtrs and then ramming the soil after
cable laying. This includes supply of half
round RCC pipe.
Excavation of trench in all kinds of soils
including soft rocky area and clearing of
roots of trees, bushes, rocks, ballast etc.,
to a depth of 1 Mtr. & width 0.3M for
track/pucca road/ Platform crossing/ level
crossing and any other place as advised by
the Engineer-in-charge including supply,
transportation and laying of RCC pipe with
collars (for jointing pipe) 150mm nominal
dia to Spec.No:IS-458 in trench and
drawing of Signalling/ Power/ Quad cables
17 17 through pipe including back filling and Metre 20
ramming after cable laying as specified in
Technical Circular No.2 of 1988 issued by
CSTE/S.E.Rly. This includes repairing and
plastering of platform/pucca road after
cable laying. RCC pipe shall be inspected
by the Rep.of Sr. DSTE /R before laying.
NOTE:-Power cable,signalling cable, Quad
cable as mentioned above,where required
shall be laid in the same trench as
signalling cable but in a separate pipe.

Supply and placing of warning tape Orange


colour of 100 mm wide printed in black as
"CAUTION OFC CABLE" at every 1 mtr.
18 18 Kilometre 0.2
interval (minimum) and to be laid in the
trench in station area and as directed by
the representative of Railway.

Excavation of trench and clearing of roots


of trees, bushes, ballast and reconditioning
etc., including bailing out water and
disposal of extra soil in Hard rocky area
19 19 Metre 100
including concreting with Chase cutting
and smoothening of inside surface of sizes
0.08 m deep and 0.17 m width at platform
and cemented floor area.

Total
Schedule B-Supply of Items
Item - 1 Supply of Items

https://www.ireps.gov.in/epsn/works/tds/publishLOAWorksLetter.do?Action=ViewPublishedLetter&nitOId=73034598&tdId=1921130&letterId=896… 6/11
3/1/24, 10:37 AM ireps.gov.in/epsn/works/tds/publishLOAWorksLetter.do?Action=ViewPublishedLetter&nitOId=73034598&tdId=1921130&letterI…

Item
S No. Description of Item Unit Qty Rate Amount
No

Supply of Rack Mountable Server as per


Annexure-A. Make- HP/LENOVO/DELL.
1 01 Inspection by RITES. Tender specific Numbers 1
MAF have to be submitted along with
tender document.

Supply of Router with SFP module as per


Annexure-E. Make :
Cisco/Juniper/HP/Netgear/Aruba/Extreme.
2 02 Numbers 2
Inspection by RITES. Tender specific MAF
have to be submitted along with tender
document.

Supply and installation of on-line, line


interactive of 10 KVA UPS as per
3 03 Annexure-D. Make- Numbers 1
APC/Luminous/Emerson/Amaraja/Uniline.
Inspection by representative of SrDSTE/R.

Supply of 24 Port 10/100/1000 Base T


with 2 Nos of 10GSFP+ port L2 Managed
switch as per Annexure-K. Make-
4 04 CISCO/HP/Aruba/juniper/Extreme/Netgear. Numbers 28
Inspection byrepresentative of SrDSTE/R.
Tender specific MAF have to be submitted
along with tender document.

Supply of Digital Multi Meter with Backlight


and LCD Excise Duty -- Display of 6000
counts having Range: AC Voltage:
600.0mV-600.0V. Resolution:0.1mV-0.1V,.
DC Voltage: 6.000V-600.0V. Resolution:
0.001V- 0.1V. AC/DC Current: 4.000A-
5 05 10.00A. Resolution 0.001A-0.01A. Numbers 1
Resistance: 400.0 Ohms to 40.00M Ohms.
Resolution : 0.1 Ohms-0.01 M Ohms.
Capacitance: 50nF-1000nF. Resolution:
0.01nF- 1mF. Frequency: 50.00 Hz-
100.0KHz. Make: Fluke/Rishabh/MECO.
Inspection by representative of SrDSTE/R.

Supply, installation, Testing and


commissioning of L-3 distribution Switch
(Minimum available port: 24 X 1G Base- T
Copper Ports, 4X 10G Base-X Fiber SFP+).
6 06 Specification as per Annexure-M. Make: Numbers 6
CISCO/Juniper/Allied Telesis/Netgear.
Inspection by RITES. Tender specific MAF
have to be submitted along with tender
document.

Supply of Thin Client as per Annexure-B.


Make- HP/Dell/Ncomputing/Zero Client or
7 07 Similar. Inspection by RITES. Tender Numbers 65
specific MAF have to be submitted along
with tender document.

Supply of 18.5 inch LED HD monitor with


VGA and HDMI input compatible with Thin
8 08 Numbers 65
Client supplied vide in SCH-B. Make-
Samsung/LG/Dell/HP. Inspection by RITES.

Supply of 6 Point Spike Protector


System(1ph,230V,50 Hz) with surge and
9 09 over voltage protection , wire for power Numbers 24
supply, power switches etc (Make: ISI
Certified). Insp. By Rep.of Sr.DSTE/R.

10 10 Supply and installation of UHD 55 inches Numbers 1


LED smart TV with OS Make

https://www.ireps.gov.in/epsn/works/tds/publishLOAWorksLetter.do?Action=ViewPublishedLetter&nitOId=73034598&tdId=1921130&letterId=896… 7/11
3/1/24, 10:37 AM ireps.gov.in/epsn/works/tds/publishLOAWorksLetter.do?Action=ViewPublishedLetter&nitOId=73034598&tdId=1921130&letterI…
Samsung/LG/Sony with all fittings
accessories and interconnection with NVR
for display data. Inspection by
representative of Sr.DSTE/R.

Supply of 24 Port fully loaded wall/rack


mounted (as per instruction of consignee)
LIU with 24 couplers, 24 connectors and
pigtails. The type of couplers, connectors &
11 11 Numbers 14
pigtails are as per site
requirement/consignee. MAKE:
PRESTON/DIGILINK/RAYCHEM or similar.
Inspection by representative of SrDSTE/R.

Supply of IP based 3 mega pixel or higher


color bullet camera with IRRange, IP67,
PoE, 25fps or higher. Itshould work proper
in Low Light, Anti-Fog Coating on Insideof
12 12 Numbers 12
Lens Cover. Make - Dahua/CP
Plus/Hikvision. It must besupplied with all
arrangement suited for outdoor
use.Inspection by Rep. of Sr. DSTE/R.

Supply of Lease line modem (2Mbps)


(combination of G.703 & V.35) and 02
such modems forms one pair. Make
13 13 Pair 13
RADWIN/CYGNUS/Realtime/Team
Engineers. Insp. by representative of
SrDSTE/R.

Supply of Core Switch having minimum 12


x 1G SFP ports, 12 x 10G SFP+ ports and
48x 1G RJ45 ports from day-1 populated
with required transceivers. Switch should
14 14 also have 04 x 40G or 100G ports. Set 1
Specification as per Annexure-L. Make:
CISCO/Juniper/Allied Telesis. Inspection by
RITES. Tender specific MAF have to be
submitted along with tender document.

Supply of High End Server with Intel Xeon


24 Core Processor, 256 GB RAM, Min. 8
TB Storage, HA supported. Specification
15 15 as per Annexure-F. Make: HP, Lenovo, Set 1
Dell.
Inspection by RITES. Tender specific MAF
have to be submitted along with tender
document.
Supply, Transportation, Installation and
Commissioning of 12 Port MPLS Router as
per Annexure-G. Make:
16 16 CISCO/NOKIA/Team Engineer/Juniper. Numbers 1
Inspection by RITES. Tender specific MAF
have to be submitted along with tender
document.

Supply, transportation, installation and


commissioning of Wireless access point as
per specifications given in Annexure-H.
17 17 Make: CISCO/Juniper/TP Link/Allied Numbers 8
Telesis. Insp.by Rep. of Sr.DSTE/R.
Tender specific MAF have to be submitted
along with tender document.

Supply, transportation, installation and


commissioning of Wi-Fi Hardware
Controller as per Annexure-J. Make:
18 18 CISCO/Juniper/TP Link/Allied Telesis. Numbers 1
Inspection by representative of SrDSTE/R.
Tender specific MAF have to be submitted
along with tender document.

https://www.ireps.gov.in/epsn/works/tds/publishLOAWorksLetter.do?Action=ViewPublishedLetter&nitOId=73034598&tdId=1921130&letterId=896… 8/11
3/1/24, 10:37 AM ireps.gov.in/epsn/works/tds/publishLOAWorksLetter.do?Action=ViewPublishedLetter&nitOId=73034598&tdId=1921130&letterI…

Supply of 10G SFP module suitable for


19 19 Switches at item no. 4, 6 & 14 above. Numbers 23
Inspection by representative of SrDSTE/R.

Supply of 1G SFP module suitable for


20 20 Switches at item no. 4, 6 & 14 above. Numbers 31
Inspection by representative of SrDSTE/R.

Supply of Column Speaker10/15 Watt.


21 21 Make: Ahuja Numbers 8
(20T)/BOSE/Studiomaster.
Inspection by representative of SrDSTE/R.
Supply of cordless Microphone, Make:-
22 22 Ahuja/Bose/Studiomaster. Inspection Numbers 1
by Rep. of Sr.DSTE/Raipur

Supply of 2 Core PVC insulated shielded


wire PA cable 24 strand copper conductor
23 23 of 0.20 mm (24/0.20 mm) Make- Metre 500
Brimson/Delton/Network or similar.
Inspection by representative of SrDSTE/R.

Supply, transportation, installation and


commissioning 02 Mbps modem leased
line modem as per Tech. Specification No.
IR/DCA-18/04, DEC 2005 or latest each
24 24 Set 6
set consisting of One V.35 Unit and One
G.703 unit. Make- Team Engineers or
Similar. Inspection by representative of
SrDSTE/R.

Supply of LCD Projector with wireless


connectivity along with ceiling mount kit
having Interface : USB ports, HDMI in (Min
25 25 2 ports), Wireless LAN IEEE 802.11b/g/n, Numbers 2
Lumens-5000 min. Make:
Sony/BenQ/Hitachi. Inspection by
representative of SrDSTE/R.

Projector Screen, Type :Tripod, Size: 5X7,


Diagonal: 100" Viewing Area (inch): 60 x
80", Aspect Ratio-4:3, Fabric: MW. Detail
26 26 Numbers 2
technical specification as per Annexure-
"C" is enclosed. Inspection by
representative of SrDSTE/R.

Supply of duplex fiber optic patch cord SC-


27 27 ST of 8 meters length. Inspection by Numbers 100
representative of SrDSTE/R.

Supply of Optic Fibre pigtail of minimum 3


meter with end connector as per site
28 28 Numbers 100
requirement. Make D Link or similar.
Inspection by: Repr. of Sr. DSTE/R.

Supply of LAN Extenders with AC power


supply and all accessories as per Spec.No.
29 29 RDSO/SPN/TC/82/2013 Rev.1 or latest. Pair 6
make-Cygnus/Tech routes/D-Link.
Inspection by representative of Sr.DSTE/R.

Supply of CAT-6 I/O box complete


30 30 set. Make-D-Link, Digisol, Numbers 160
ANDTRONICS.
Inspection by representative of SrDSTE/R.
Supply of standalone Non PoE Media
Converter Single Mode and single fiber,
Optical to UTP (1000BASE BX-
10U/1000BASE BX10D to 1000BASE-T)
31 31 Numbers 19
with AC power supply as per Spec.
No.RDSO/SPN/TC/103/2013 Rev.1 or
latest. Inspection by representative of
SrDSTE/R.

https://www.ireps.gov.in/epsn/works/tds/publishLOAWorksLetter.do?Action=ViewPublishedLetter&nitOId=73034598&tdId=1921130&letterId=896… 9/11
3/1/24, 10:37 AM ireps.gov.in/epsn/works/tds/publishLOAWorksLetter.do?Action=ViewPublishedLetter&nitOId=73034598&tdId=1921130&letterI…

Supply of 16/8 Port Digital Line Card


suitable for Karel DS- 200 exchange
32 32 installed at DRM Complex, Raipur. Make: Numbers 1
Karel. Inspection by representative of
SrDSTE/R.

Supply of 16 Port Analog Line Card


suitable for Karel DS-200 exchange
33 33 installed at DRM Complex, Raipur. Make: Numbers 1
Karel. Inspection by representative of
SrDSTE/R.

Supply of 24 port analog extension card


compatible to existing Avaya Make
34 34 Numbers 1
exchange in Raipur Division. Make:Avaya
or compatible. Insp. By Rep. of
Sr.DSTE/R.
Supply and installation of full duplex digital
phone campatible with existing Karel DS-
35 35 Numbers 10
200. Make/Model Karel ST-26FD. Insp. by
Rep. of Sr.DSTE/R.

Supply of Push Button Telephone with ID


caller & rosette box (RJ-11) equivalent or
higher to Model No. DF- 5300/Alkatel
36 36 Numbers 60
Model No.29339 Make:-
alkatel/beetal/panasonic. Insp.by Rep. of
Sr.DSTE/R.

Supply of 1 KVA UPS, with AVR for single


phase AC 160V to 280V input including
installation as advised by Railway's
37 37 Numbers 7
Engineer. Make - APC / Wipro/Libert
/Samtek / Uniline. Inspection by Rep. of
Sr.DSTE/R.

Supply of 20 pair twisted pair PVC switch


board cable, conductor of size 0.6mm. dia
38 38 annealed copper conforming to IRS-TC- Metre 500
24/91 or ITD 1138. Inspection by Rep. of
SrDSTE/R.

Supply of HDMI cable of 2 Mtr length.


39 39 Make: CP Plus/Belkin/Swagger or similar. Numbers 4
Inspection by representative of SrDSTE/R.

Supply of 6 fibres Optical Fibre Cable with


armour single mode optical fibre as per
40 40 ITU-TG-6520 specification. Make- D- Metre 200
Link/Finolex/RPG/Sterlite. Inspection by
representative of SrDSTE/R.

Supply of 8 port POE Switch 10/100/1000


Mbps Make; Zyxel/HP/juniper/D-
41 41 Numbers 2
Link/Cisco/Aruba/TP Link. Insp. By Rep. of
Sr.DSTE/R.

Supply of UTP CAT 6 Cable (Roll is 305


42 42 Mtr). Make Amp or Molex. Inspection by Metre 610
Rep. of SrDSTE/R.

Supply of Cat-6 Patch Cord - 2mts length.


43 43 Make: D-link/ Dax/ Systimax. Insp. By Numbers 20
Rep. Of Sr.DSTE/R.

Supply of permenantly lubricated HDPE


pipe with outer dia50mm, inner dia -
42mm thickness - 4mm with suitable
couplers, plugs, end caps etc. as per
44 44 Kilometre 0.2
technical specification No. G/CDS- 08/01
Dec. 1999. Supply to be made in length of
500 mtrs with + /-10% tolerance.
Inspection by representative of SrDSTE/R.

https://www.ireps.gov.in/epsn/works/tds/publishLOAWorksLetter.do?Action=ViewPublishedLetter&nitOId=73034598&tdId=1921130&letterId=896… 10/
11
3/1/24, 10:37 AM ireps.gov.in/epsn/works/tds/publishLOAWorksLetter.do?Action=ViewPublishedLetter&nitOId=73034598&tdId=1921130&letterI…

Supply of 20 pair CT Box. Inspection by


45 45 Numbers 4
Rep. of SrDSTE/R.

Supply of RJ-45 connector for networking.


46 46 Make Dlink/Systimax/i-ball Insp. By Rep. Numbers 100
Of Sr.DSTE/R.

Supply of Wifi router Make Netgear model


47 47 R7000P or similar Insp.by Repr. of Numbers 4
Sr.DSTE/R.

Supply of Router with 8 Nos V.35 WAN


ports installed and 8 Nos V.35 serial cables
compatible with existing Cisco 2900 and
48 48 Numbers 1
3800 series routers. Make- Cisco-
2921/Juniper/Nokia. Inspection by
representative of SrDSTE/R

Supply of Optical fibre termination box for


2 x 24 fibre armoured cable complete with
all accessories with the fixing arrangement
49 49 to accommodate all the fibres as per Numbers 5
specification No. IRS:TC:81-2000 (with
latest amendment). Inspection by Rep. of
SrDSTE/R.

Supply of PVC pipes conduits of nominal


size 25mm, outer dia 25mm, inner dia
50 50 Metre 100
22.1mm approx, colour gray/white, ISI
marked inspection by rep. of SrDSTE/R.

Supply of rack (9U) with all accessories.


51 51 Make:Valrack/HCL /Hunt/Rontel/D- Numbers 4
link.Insp by rep. of Sr.DSTE/R.

Supply and installation of on-line, line


interactive2 KVA UPS battery backup of
52 52 120minutes at rated load. Make: Numbers 2
APC/Uniline/Amararaja. Insp.by Rep. of
Sr.DSTE/R.

Supply of E1 to Ethernet (single port)


converter. Make- Team Engineers/MRO-
53 53 TEK/Techroutes. As per spec. attached Pair 1
in
Annexure-N. Inspection by representative
of SrDSTE/R.
Supply of Crimping tool. Make:D-Link/I-
54 54 ball/Pro-Tech. Insp.by Rep. of Numbers 1
Sr.DSTE/Raipur.

Total