The document provides a step-by-step solution to determine the development length of reinforcing bars in a concrete beam. It first calculates the length using code provided tables, then assuming a coefficient of lateral friction of 0, and finally calculates the coefficient and uses it to determine the final required length.

Uploaded by

Joeven Dinawanao
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
75 views

Development Length RC

The document provides a step-by-step solution to determine the development length of reinforcing bars in a concrete beam. It first calculates the length using code provided tables, then assuming a coefficient of lateral friction of 0, and finally calculates the coefficient and uses it to determine the final required length.

Uploaded by

Joeven Dinawanao
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

engr.

paanod
Problem: Using NSCP 2015, determine the development
length required for the epoxy coated bars as shown in the
figure. The concrete beam is reinforced with 4-25mmØ with
𝑓𝑦 = 420 𝑀𝑃𝑎, and concrete compressive strength 𝑓𝑐′ = 21 𝑀𝑃𝑎.
Assume normal weight concrete.

1. Using table 425.4.2.2


2. Assuming 𝐾𝑡𝑟 = 0
3. With the computed value of 𝐾𝑡𝑟

engr.paanod
Solution:
Using table 425.4.2.2

𝑓𝑦 𝜓𝑡 𝜓𝑒
𝐿𝑑 = 𝑑𝑏
1.7𝜆 𝑓𝑐 ′

engr.paanod
Solution:
Using table 425.4.2.2

𝑓𝑦 𝜓𝑡 𝜓𝑒
𝐿𝑑 = 𝑑𝑏
1.7𝜆 𝑓𝑐 ′
𝜓𝑡 = 1.0 for bottom bars
𝜓𝑒 = 1.5
for epoxy coated with clear spacing less than 6𝑑𝑏
The product 𝜓𝑡 𝜓𝑒 need not exceed 1.7

𝜓𝑡 𝜓𝑒 = 1.0 1.5 = 1.5 < 1.7 ∴ok


Solution:
Using table 425.4.2.2

𝑓𝑦 𝜓𝑡 𝜓𝑒
𝐿𝑑 = 𝑑𝑏
1.7𝜆 𝑓𝑐 ′

(420)(1.0)(1.5)
𝐿𝑑 = 25 = 2021.72 𝑚𝑚
1.7(1.0) 21
𝐿𝑑 = 2021.72 𝑚𝑚 > 300 𝑚𝑚

∴ 𝑳𝒅 = 𝟐𝟎𝟐𝟏. 𝟕𝟐 𝒎𝒎

engr.paanod
Solution:
Assuming 𝐾𝑡𝑟 = 0

𝜓𝑡 = 1.0 for bottom bars


𝜓𝑒 = 1.5 for epoxy coated
with clear spacing less than 6𝑑𝑏
𝜓𝑠 = 1.0 for 25mmØ bars
𝒄𝒃 is the lesser of:
a) The distance from center of a bar
to the nearest concrete surface,
and
b) One-half the center-to-center
spacing of bars or wires being
developed
Solution:
Assuming 𝐾𝑡𝑟 = 0
𝒄𝒃 is the lesser of:
a) The distance from center of a bar to the nearest
concrete surface = 80 mm
b) One-half the center-to-center spacing of bars or
80
wires being developed = 2 = 40 𝑚𝑚
𝑈𝑠𝑒 𝑐𝑏 = 40 𝑚𝑚
𝑐𝑏 + 𝐾𝑡𝑟 40 + 0
= = 𝟏. 𝟔 < 2.5 ∴ 𝑜𝑘
𝑑𝑏 25
𝑓𝑦 𝜓𝑡 𝜓𝑒 𝜓𝑠
𝐿𝑑 = 𝑑𝑏
𝑐𝑏 + 𝐾𝑡𝑟
1.1𝜆 𝑓𝑐 ′
𝑑𝑏
engr.paanod
Solution:
Assuming 𝐾𝑡𝑟 = 0

𝑓𝑦 𝜓𝑡 𝜓𝑒 𝜓𝑠
𝐿𝑑 = 𝑑𝑏
𝑐𝑏 + 𝐾𝑡𝑟
1.1𝜆 𝑓𝑐 ′
𝑑𝑏

420(1.0)(1.5)(1.0)
𝐿𝑑 = 25
1.1(1.0) 21 1.6

𝑳𝒅 = 𝟏𝟗𝟓𝟐. 𝟖𝟎 𝒎𝒎
Solution:
With computed value of 𝐾𝑡𝑟

40𝐴𝑡𝑟
𝐾𝑡𝑟 =
𝑠𝑛
𝜋
40 4 10 2 (2)
𝐾𝑡𝑟 =
(200)(4)

𝐾𝑡𝑟 = 7.854 𝑚𝑚

𝑐𝑏 + 𝐾𝑡𝑟 40 + 7.854
= = 𝟏. 𝟗𝟏𝟒 < 2.5 ∴ 𝑜𝑘
𝑑𝑏 25
Solution:
With computed value of 𝐾𝑡𝑟

𝑓𝑦 𝜓𝑡 𝜓𝑒 𝜓𝑠
𝐿𝑑 = 𝑑𝑏
𝑐𝑏 + 𝐾𝑡𝑟
1.1𝜆 𝑓𝑐 ′
𝑑𝑏
420(1.0)(1.5)(1.0)
𝐿𝑑 = 25
1.1(1.0) 21 1.914

𝑳𝒅 = 𝟏𝟔𝟏𝟕. 𝟕𝟑 𝒎𝒎
Plate No. 5

Problem No.1:
Using NSCP 2015, determine the
tensile development length
required using:
a) Using table 425.4.2.2
b) Assuming 𝐾𝑡𝑟 = 0
c) With the computed value of 𝐾𝑡𝑟.
The concrete beam is
reinforced with 4-25mmØ
uncoated bars with 𝑓𝑦 = 420 𝑀𝑃𝑎 ,
and concrete compressive
strength 𝑓𝑐′ = 28 𝑀𝑃𝑎. Assume
normal weight concrete.
engr.paanod
Plate No. 5

Problem No.2:
Using NSCP 2015, determine the
tensile development length
required using:
a) Using table 425.4.2.2
b) Assuming 𝐾𝑡𝑟 = 0 4 #20
c) With the computed value of 𝐾𝑡𝑟.
The concrete beam is
reinforced with 4-20mmØ epoxy
coated bar with 𝑓𝑦 = 420 𝑀𝑃𝑎, and
concrete compressive strength
𝑓𝑐′ = 28 𝑀𝑃𝑎. Assume normal
weight concrete.
engr.paanod