0% found this document useful (0 votes)
798 views52 pages

2023 Doppler Catalog

Guangzhou Doppler Electronic Technologies is a Chinese company focused on R&D and manufacturing of ultrasonic non-destructive testing instruments, probes, and scanners. They produce phased array instruments, conventional probes, and automatic scanning systems for industrial NDT applications.

Uploaded by

Amit Hasan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
798 views52 pages

2023 Doppler Catalog

Guangzhou Doppler Electronic Technologies is a Chinese company focused on R&D and manufacturing of ultrasonic non-destructive testing instruments, probes, and scanners. They produce phased array instruments, conventional probes, and automatic scanning systems for industrial NDT applications.

Uploaded by

Amit Hasan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 52

Build a world-class NDT brand

MANUAL
Instrument,Probe,Scanner

Contact Us
Adds: No.1501 Kaichuang Avenue,Huangpu District,
Guangzhou,China,510530
Tel: 020-82260495 82086632
Fax: 020-82086200
Email: [email protected]
Web: www.cndoppler.com
Guangzhou Doppler Electronic Technologies Co., Ltd.

© 2023 All rights reserved by Doppler. All specifications are subject to change without notice.
PROFILE CULTURE

Guangzhou Doppler Electronic Technologies Incorporated Company is a high-tech enterprise


focused on R&D, manufacturing of ultrasonic instruments & transducers (probes), and is
Philosophy
committed to provide high-level solutions to the nondestructive testing industry. The company's Pursuit of Excellence—Constantly Improving, and Try the Best
products cover phased array instruments, probes, scanners and automatic systems, with the Honest and Trustworthy—Be Sincerely, and Keep the Promise
capability of customize all kinds of special probes, phased array instruments. A variety of
Solidarity and Cooperation—Integrating Resources and Create
products meet the advanced international level.
a Prosperous Business

Doppler has built production lines with advanced level and passed the ISO 9001: 2015 quality
management system certification, CE certification and EN12668 standard compliance
Mission
certification. Doppler is the first enterprise that has established advanced probe production
Service to the Community for the Benefit to Human Safety
line, also has developed the domestic first phased array unit.

Doppler will continue to focus on industrial non-destructive testing industry, promote advanced Vision
technology development and industry standards establishing, and strive to build a high level, Creating a World-Class NDT Brand
diversified modern enterprise.

Core Values
Love, Integrity, Innovation, Dedication
HONOR

High-Tech Enterprise of China Hundred Innovation Benchmarking National Key New Product Certificate National –Lever New Special
Enterprises in Guangzhou Expertise Enterprise

Certificate of National CE Certificate Certificate of Adopting Guangdong Province European EN-12668 ISO9001 Quality Managemet
Torch Program Project International Standard High Tech Product Standard Compliance System Certification
Product Mark Certificate Certificate
Conventional UT Probes

CONTENTS
Conventional UT Probe Instruction 34/35 Delay Line Probes and Wedges 61/62
Probe Data Sheet 36/37 TOFD Probes and Wedges 63/64
Wear Resistant Probes 38/42 Immersion Probes 65/69
Normal Incidence Shear Wave Probes 43/43 High Frequency Probes 70/70
Protective Face Probes 44/46 High Temperature Delay Line Probes and Wedges 71/72
Dual Element (TR) Probes 48/50 Thickness Measurement Probes 73/74
Angle Beam Probes and Wedges 51/57 Probes for Custom and Specific Applications 74/76
Spot Weld Probes 58/58 Cables/Adapters 77/78
TRL Angle Beam Probes 59/60

Scanners
FC Series DSC Series
FC-01 / FC-26 80/80 Corrosion Scanner DSC-06 90/90
FC-02 / FC-02+ 81/81 PE Pipe Weld Scanner DSC-11 90/90
Instruments FC-29 / FC-30 82/82 Automatic Crawler DSC-03 91/91
Phascan Portable Phased Array Flaw Detector PAUT Board MOS Series Multi-functional Automatic Crawler DSC-08 92/92
02/02 09/10
Phascan II Portable Phased Array Flaw Detector Multichannel Board Girth Weld Scanner MOS-01 83/83 Guide Rail Scanner for Pipeline DSC-27/DSC-02 93/93
03/04 11/12
Flexscan Portable Phased Array Flaw Detector Application Cases TKY Conner Weld Scanner MOS-02 83/83 Multi-functional Automatic Crawler DSC-28 94/94
05/06 13/14
Novascan Portable Phased Array Flaw Detector 07/08 PA/TOFD Dual Probes Scanner MOS-03 84/84 FS Series
Chain Scanner for Large Pipelines MOS-04 84/84 Corrosion Scanner FS-04/FS-05 95/95
MOS-05/Spiral Welded Pipe Scanner MOS-40 85/85 Elbow Corrosion Scanner FS-06 95/95
MOS-20/Pipe Seat Weld Scanner MOS-07 86/86 XY Dual-axis Automatic Scanner FC-XY02-DD 96/96
Phased Array Probes CRS Series Wheel Encoder ENC-10 96/96

Ordering Instructions 16/17 Wedge Integrated Series/Concave Series 24/24 CRS-7/CRS- 8(Small Diameter Pipes) 87/87
Linear Series 18/18 Flexible Array Series/High Temperature Series 25/25 CRS-15(Small Diameter Pipes) 88/88
Laterally Focused Array Series 19/19 Photoacoustic Probes/Power Probes 26/26 CRS-25(Middle Diameter Pipes) 89/89
Immersion Series 20/20 Air - coupling Probes 27/27 CRS-34(Small Diameter Pipes) 89/89
DLA/DMA Series 21/21 Other Special Probes 28/30
Water Bag Probes/Bolt Probes 22/22 Wedges/Connectors/Adapters 31/32
Matrix Array Series/Wheel Series 23/23
Phased Array Flaw Detector
Instrument New Upgrades
Support AutoCAD Import Function!
16/64, 32/64, 32/128, 32/128PR receiver/pulser channels for phased array
Dual independent channels for high-performance TOFD detection
Embedded focal law calculator, which can perform:
Four kinds of scanning modes: linear, sectorial, depth and static
Four kinds of focal types: true depth, sound path, projection, and focal plane
Optional display mode of A / B / S / C / TOFD, etc.
Calibration is more convenient to implement and can be calibrated for each beam
Multiple groups for parallel scanning, comparable to many instruments working simultaneously
Negative square wave pulse, with resolution up to 2.5ns, PRF up to 20khz
10.4" TFT LCD color touch screen, resolution 800*600 pixel

Instrument 02
PHASCAN VS PHASCAN II
II Parameter PA Channel
PhaScan
Conventional Channel PA Channel
PhaScan II
Conventional Channel
Phased Array Flaw Detector Configuration
Receiver / Pulser 32/128 2/2 32/128 2/2
Range 9900μs 9900μs 9900μs 9900μs
Sampling Rate 100MHz 100MHz 100MHz 100MHz
Max Length of A scan 8192 8192 32768 32768
Data Collection No. of Focal Laws 1024 NA 1024 NA
True Depth/Sound Path/ True Depth/Sound Path/
Focusing Type ΝΑ ΝΑ
Projection/Focal Plane Projection/Focal Plane
Test Mode PE / PC PE / PC / TT / TOFD PE / PC PE / PC / TT / TOFD
PHASCAN II FEATURES PHASCAN II VS PHASCAN Voltage 50V / 100V
Negative Square Wave
100V / 200V / 400V
Negative Square Wave
50V / 100V
Negative Square Wave
100V / 200V / 400V
Negative Square Wave
Pulse Shape
Pulser Pulse Width 30-500ns 30-500ns 30-500ns 30-500ns
32/64PR, 32/128PR receiver/pulser channels Rise Time <8ns <8ns <8ns <8ns
for phased array
CPU4×1.2GHz 6-7 times
higher computing capability
7 PRF 20KHz 20KHz 20KHz 20KHz
Delay 10μs / 2.5ns 10μs / 2.5ns 10μs / 2.5ns 10μs / 2.5ns
128GB SSD fast data storage Gain Range 0-80dB 0-110dB 0-80dB 0-110dB
Single data file up to 4GB
>10 times storage
10 Receiver Bandwidth 0.5-20MHz 0.5-20MHz 0.5-20MHz 0.5-20MHz
Receiver Delay 10μs / 2.5ns 10μs / 2.5ns 10μs / 2.5ns 10μs / 2.5ns
2D matrix array, 3D simulation
CAD module import
Storage speed
2~3 times
3 Scan/Display
Scanning Type
Display Mode
Linear/Sectorial
A/B/C/S,PA-TOFD
NA
A/B/C TOFD
Linear/Sectorial
A/B/C/S,PA-TOFD
NA
A/B/C TOFD
Measure Units mm / inch mm / inch mm / inch mm / inch
SDK
Fast & Reliable
4 times single file size
4 Points 16 16
TCG Dynamic Range 40dB 40dB
Max Gain Slope 40dB/μs 40dB/μs
Incredibly easy to use
Report HTML HTML
Data Storage Pluggable Storage USB Disk / SD Card USB Disk / SD Card/SSD(Build-in)
Size 10.4 inch 10.4 inch
Display Screen Resolution 800*600pixel 800*600pixel
Type TFT LCD Resistive Touch Screen TFT LCD Capacitive Touch Screen
USB 3 3
Internet 10/100M 100/1000M
I/O Port
Video Output DVI/VGA Compatible DVI/HDMI
Encoder Single Axis Dual Axis
Language English / Chinese English / Chinese
DC Supply Voltage 15VDC 4A 15VDC 4A
Battery & Li-ion Battery Li-ion Battery
Battery Type
Power Supply Battery Life 6 Hours 6 Hours
Weld Detection of Dissimilar Metals Size 325mm×230mm×130mm 325mm×230mm×130mm
Case Weight
in Austenitic Stainless Steel 4.5Kg(Without Battery) 4.5Kg(Without Battery)
CPU 800MHz 4 × 1.2GHz
Hardware USB Disk FAT32 / NTFS FAT32 / NTFS
SD Card 8GB 128GB
2-axis C-Scan N/A YES
3D Beam Simulation N/A YES
Matrix Array N/A YES
Module Import N/A YES
Topview C-Scan N/A YES
Software TKY Geometry Import N/A YES
Real-time 3D imaging N/A YES
Inspection of Pipe XY-dual Axis Scanning Multi-Touch Interface N/A YES
Seat Intersection Line SDK Half Support Support
Online Monitoring Half Support Support
Sigle File Size 256M 1GB

03 Instrument Instrument 04
Performance
Phased Array Flaw Detector Parameter PA Module Conventional UT
Receiver / Pulser 32/64 1/2
Range 9900μs 9900μs
Configuration
Flexscan is the latest PAUT flaw detector developed by Doppler. It’s a continuity of Phascan, with Velocity 635-15240m/s 635-15240m/s
excellent performance. With 43% volume and 22% weight reduced, also hardware and software Focal Law 1024 NA
Test Mode PE / PC PE / PC / TT / TOFD
optimized, Flexscan is ideal for on-site inspection. Voltage 50V / 100V/130V 100V / 200V / 400V
Pulse Shape Negative Square Wave Negative Square Wave
16/64PR, 32/64PR receiver/pulser channels for phased array Pulse Width 30-500ns 30-500ns
Pulser
Rise Time <8ns <8ns
8.4" TFT LCD color touch screen, easy to operate
PRF 20KHz 20KHz
PA, TDFD and conventional UT can be performed simultaneously Delay 10μs / 2.5ns 10μs / 2.5ns
Multiple groups for parallel scanning, comparable to many instruments Damping N/A 50Ω/200Ω
working simultaneously Gain 0-80dB 0-110dB
Bandwidth 0.5-18MHz 0.5-20MHz
Fast calibration of velocity, wedge delay, sensitivity, TCG and so on Receiver Input Impendance 200Ω 133Ω
Fast setting of many kinds of common weld graphs Input Capacitance 60pF 60pF
Support autocad import function Delay 10μs / 2.5ns 10μs / 2.5ns
Type Linear/Sectorial NA
Optional display mode of A / B / S / C / TOFD / Offline 3D
Scan/Display Display Mode A/B/C/S A/B TOFD
New upgraded offline data analysis software, more powerful Unit mm / inch mm / inch
Points 16
TCG Dynamic Range 40dB
Max Gain Slope 40dB/μs
DAC Points 16
Gates A/B/I
Gate Threshold 0-98%
Trig Mode Peak / Edge
Report HTML
Data Storage Storage Devices USB Devices / SD Card
Size 8.4 inch
Display Screen Resolution 800*600pixel
Type TFT LCD Touch Screen
USB 2
Internet 10/100M
I/O Port
Video Output HDMI
Encoder LEMO 16-Pin
Language English / Chinese
DC Supply Voltage 15V DC 4A
Power Supply Battery Type Li-ion Battery
Battery Life 4 Hours
Size 296mm×209mm×89mm
Case
Weight 3.5Kg(Without Battery)

05 Instrument Instrument 06
Performance
Phased Array Flaw Detector Parameter PA Module Conventional UT
Receiver / Pulser 32/128 2/2
Configuration Range 9900μs 9900μs
Velocity 340-15240m/s 340-15240m/s
New Phased Array Flaw Detector Test Mode PE / PC PE / PC / TT / TOFD
Voltage 50V / 100V 100V / 200V / 400V
with 3D TFM/FMC Pulse Shape Negative Square Wave Negative Square Wave
Novascan is a full-featured phased array inspection tool. In addition Pulser Pulse Width 30-1000ns/2.5ns 30-1000ns/2.5ns
to the phased array function and the independent two-channel Rise Time <8ns <8ns
TOFD inspection function, it is the first time at home and abroad to PRF 20KHz 20KHz
realize 3D TFM technology on a portable instrument, with clear and Delay 0-20μs/2.5ns 0-20μs/2.5ns
delicate imaging. At the same time, it supports 2D TFM with imaging Gain 0-120dB 0-120dB
points 1024 * 1024, which greatly improves imaging and shows Receiver Bandwidth 0.5-20MHz 0.5-20MHz
small defects more clearly. Delay 20μs/2.5ns 20μs/2.5ns
Sampling Rate 100MHz 100MHz
No. of Focal Laws 512(Customizable 1024) NA
Dual Role Data Collection
Focusing Type
True Depth/Sound Path/
NA
The Novascan has a FPGA connection interface, and can be used as Projection/Focal Plane
a phased array board, which can transmit the underlying data to Detection FW/HW+/HW-/RF FW/HW+/HW-/RF
the user, making it easier for users such as research institutes and Type Linear/Sectorial NA
universities to conduct secondary development. Scan/Display Display Mode A/B/C/S/3D/TopC A/B(TOFD)
Unit mm mm
Points 16
Powerful 3D View Function TCG Dynamic Range 40dB
Support 3D view, defects are visually displayed in 3D workpieces, Max Gain Slope 40dB/μs
defect position and size are intuitive and clear, and it is more Report WORD
convenient for defect judgement. Storage Devices USB Devices / SSD (128G)
Data Storage
Single File Size 4G
Size
Powerful Scanning Simulation Resolution
10.4 inch
1024*768pixel
Display Screen
Function Viewable Area 211mm*158mm
Equipped with a new scan planning process, it can realize 3D focus Type IPS Capacitive Touch Screen
law simulation, multiple groups of simultaneous simulation, etc., USB 2
and greatly simplified the user setting interface. It can help to Internet 2(Top x86,1000Mb/s. Bottom FPGA,1000Mb/s)
I/O Port WIFI Support USB External WiFi Transmission Customization
complete the necessary steps such as process simulation and
calibration in the shortest time. Video Output HDMI 1.4b
Encoder LEMO 16-pin
Language English/Chinese
More Application Fields DC Supply Voltage 15V DC 100W
The equipment is equipped with a two-dimensional coded interface, Power Supply Battery Type Li-ion 11.25V/99.6Wh
which can realize high-speed two-dimensional scanning; it supports Battery Life 4 Hours
Size 360mm×260mm×130mm
DLA and DMA probes, which can be used for austenitic stainless Case
Real-time 3D Imaging Multi-group Simulation Weight 6Kg(Without Battery)
steel workpiece. With 32 groups for simultaneous detection and 8
IP Lever IP65
groups displayed on the same screen, it is more suitable for
complex detection cases.

07 Instrument Instrument 08
Options Parameter

BORD SERIES Configuration


Receiver / Pulser 32/64;32/128

PAUT/UT Board Velocity


Test Mode
340-15240m/s
PE / PC
Voltage (Customizable 200V)
50V / 100V
Pulse Shape Negative Square Wave
Pulse Width 30-1000ns/2.5ns
Pulser
Rise Time <8ns

Robust - PAUT Board PRF 20KHz(Customizable 40KHz)


Delay 0-20μs/2.5ns
Damping NA
32/64PR, 32/128PR
Gain 0-120dB
Optional display mode: A /B /S /C /3D
Bandwidth 0.5-20MHz
Extended hardware and software can be provided to redevelop Receiver
Delay 50μs/0.1μs
Use for all kinds of automatic phased array ultrasonic Input Impendance 200Ω
testing system platform Sampling Rate 100MHz
Focal Law Number 512(Customizable 1024)
Data Collection Focus Type True Depth/Half Sound Path/Projection/Any Surface
Detection FW/HW+/HW-/RF
Powerful Simulation, Imaging, and Data Synchronization Initial Pulse/Gate
Analysis Software Max Point Number Maximum 4 Million
TFM TFM Aperture 64/128 Transmit
Support 3D & 2D TFM,real-time TFM imaging above 1024*1024 points can be achieved
Focal Mode TT,TTT,TTTT,LL,LLL,LLLL,TLT,TLL,LTT
3D real-time process simulation
Type Sectorial/Linear
Diversified gate types, easy to remove interference signals
Scan/Display Display Mode A/B/C/S/3D/Top-C
Equipped with intelligent corrosion detection and analysis module, which can automatically calculate the corrosion area mm
Unit
Support fillet weld detection of pipe seat, real-time update of weld cross section
Points 16
TCG Dynamic Range 40dB
Max Gain Slope 40dB/μs
Band Filter Full Date Real Time Averaging
Internet 100/1000M
I/O Port
Encoder LEMO 16-pin
Gates No. 4
Gate Threshold 0-98%
Trig Mode Peak/Edge/ Rectangle
Power Supply DC Supply Voltage 15V/4.2A
Size 350mm×245mm×55mm
Case
Weight 3.4Kg
TFM (Spherical Hole) Tube Seat Sectorial Scan 3D Display

09 Instrument Instrument 10
Multiscan - Multi-channel Ultrasonic Board
Options Parameter
Multiscan independent multi-channel ultrasonic board adopts modular unit design, which can integrate multiple modules according to user
needs to form a larger multi-channel system, such as 4 * n (n ≤ 8) channel ultrasonic testing system. The combination of boards is flexible and No. of Channel 4*N (N≤8)
efficient, and various triggering modes and synchronization between devices are supported among various modules. With parallel sampling Detection Range 0.5~9999mm(Steel, Longitudinal)
mode and PRF up to 10 kHz per channel, there is no pressure for high-speed automatic detection.
Velocity 1000~15000m/s

Delay 0~50μs
The multi-channel board provides a complete SDK development kit, which can carry out secondary development according to the application
characteristics of different industries, and is suitable for automatic production lines in metallurgy, steel, railway, machinery and other Pulse Voltage 100V/200V/400V(Negative Square Wave)
industries.You can also create customized solutions according to user needs to realize the whole service from design to installation and
Pulse Width 30-1000ns,Step of 2.5ns
commissioning. At the same time, Multiscan provides supporting general-purpose software, which is convenient for users to conduct basic
research experiments. It is performance reliable and easy to maintain. All kinds of communication interfaces adopt universal design, which can Pulse Rise Time ≤8ns
better match automation production lines and provide guarantee for the quality control of industrial automation products. Inspection Mode PE/PC

Bandwidth 0.3-24MHz

PRF 10*N KHz(N= No. of Channels)

Gain Range 0-120dB

TCG Gain Range 40dB

8-Channel Board Rectification Mode FW/HW+/HW-/RF

Gate A/B/C

Horizontal Linearity Error ≤0.1%

Vertical Linearity Error ≤2%

Surplus Sensitivity ≥60dB

Sampling Rate 100MHz


4-Channel Board
Data Transfer Bandwidth 1000Mbps

Communication Interface Gigabit Ethernet

Software Features Operating Temperature -10~+45°C

Power Supply DC:15V/4.2A

Dimensions 360*200*65mm

Weight 2.2Kg

Multi-group Detection Process TOFD Beam Coverage Simulation TOFD Analysis Module

11 Instrument Instrument 12
Electron Beam Welding(AutoCAD Geometric) Quality Inspection of Vehicle Parts

PHASED ARRAY
Ultrasonic Inspection Applications

Straddle Type Turbine Root(AutoCAD Geometric) Wind Turbine Bolt Inspection(Cylindrical Guided Wave)

Circumferential Weld Inspection of Oil and Gas Pipelines Fillet Weld Inspection of Concrete Pump Truck

TFM Inspection of Groove FPR Composite Wind Turbine Inspection

Fillet Weld Inspection of Socket


(Real-time Update of Weld Cross Section) PAUT Inspection for Butt Joint of PE Pipeline

Aircraft CFRP Composite R Conner Inspection


Inspection of Aviation Aluminum Honeycomb Panel (Concave Probe)
TFM Inspection of Corrosion Inspection of
TOFD Inspection for Butt Joint of PE Pipeline Small Screw Boiler Water Wall

13 Instrument Instrument 14
PHASED ARRAY
Probes

PA Probes
Ordering Instructions
Doppler conventional ultrasonic phased array probes are widely used, with frequency range 0.5MHz to 20MHz, element number 8 to 1024
and internal element pitch 0.2mm to 2.0mm. The array configuration includes Linear(L), Matrix(M), Annular(A), Concave(C), Convex(V), wedge
integrated, etc. Other types of probes can be customized according to customers’ requirements. Wedge, connectors, adapters and extension
cables can also be customized.

Linear Focused Linear Array 2D Array Flexible Convex Concave Focused Concave

Annular Daisy Arrays Annular Focusing Circular Array Wedge Integrated-Linear Array Dual Linear Dual Matrix

A: Active aperture Px:Primary pitch


E: Elevation Py:Secondary pitch
g: Internal element spacing IEx:Primary element spacing
w: Element width IEy:Secondary element spacing
p: Elementary pitch Lx:Primary aperture
n: Number of elements in the PA probe Ly:Secondary aperture
Active aperture: A = n × p
Precise active aperture: A = (n - 1)× p + w

1D Probe parameters 2D Probe parameters

17 PA Probes PA Probes 16
Linear Array Series
Probe Model Illustration:
10 L 64 - 0.6 x 7 - DP3 - U - 110 - 2.5 - T1 Features
Frequency Array No. Pitch Elevation Probe Cable Cable Cable Connector
type elements type jacket capacitance length type Conventional array probe, standard series for phased array instrument
type
Applicable to most conventional scenarios

Wedge Model Illustration:


SDP3 - N 55 S - I HC - AOD 203.2 (HT)
Wedge Mounting Refraction Wave Auxiliary Curvature Tube High
type method angle type use type diameter temperature

Probe Model Illustration Wedge Model Illustration


Frequency 1= 1MHz 2.5= 2.5MHz 5= 5MHz 7.5= 7.5MHz 10= 10MHz 20= 20Mhz Wedge Type Casing type matched to the wedge XX
Array Type L(Linear) V(Convex) C(Concave) M(Matrix) A(Annular) S(Special) Mounting Method Angle between primary axis of probe and wedge
No. Elements 64= 64 Elements
DP4 DP5 DP2
N= Normal L= Lateral
DP6
Pitch 0.6= 0.6mm Refraction Angle 0= 0° 45= 45° 55= 55° DP1 DP3
Elevation 7= 7mm Wave Type S= Share Wave L= Longitudinal Wave
Probe Type DP3= DP3 Series IHC I= Irrigation
Cable Jacket Type U= PU ( Low smoke halogen-free ) H= Scanner yoke attachment points
Cable Capacitance 110= 110pf/m 50= 50pf/m C= Adjustable carbide wear pins
Cable Length 2.5= 2.5m Curvature Type AOD= Axial outside diameter (circumferential scan)
Connector Type T1: QLC-260P P1: I-PEX 30056 H1: Hypertronics AID= Axial inner diameter (circumferential scan)
D1: DL-156P D2: DL-260P D3: DL-96P COD= Circumferential outside diameter (axial scan)
M1: MOLEX 78P J1: D38999/26FF35SN C1: CONEC 78PIN CID= Circumferential inner diameter (axial scan)
SOD= Sphere outside diameter Specifications and Dimensions
SID= Sphere inner diameter
Tube Diameter 203.2= 203.2mm Casing Dimensions
(HT) High temperature wedge Active
Frequency Pitch Elevation Case
Model Elements Aperture Long (L) Width (W) Height (H)
(MHZ) (mm) (mm) Type
(mm) mm mm mm

5L32-0.3x10 5 32 0.3 9.6 10


13.4 28.5 20 DP1
Custom Probe Description 5L16-0.6x10 5 16 0.6 9.6 10
5L32-0.6x10 5 32 0.6 19.2 10 23 28.5 23 DP2
We have a professional R&D technical team and a world-class ultrasonic transducer production line. We can customize transducers according to customer requirements. To develop 5L64-0.6x10 5 64 0.6 38.4 10 42.5 28.5 23 DP3
self-defined transducers for customers, we need to know:
2.25L32-0.75x24 2.25 32 0.75 24 24 29.5 30.5 25 DP4
1. Application scenarios, how to use existing probes 5L64-1.0x10 5 64 1 64 10 70 28.5 23 DP5
2. Probe’s frequency, number of array elements, array element spacing, array element length, array configuration, probe type
5L128-1.0x10 5 128 1 128 10 135 29.5 30 DP6
3. Requirements such as size restrictions
4. Cable length and environmental requirements 5L32-1.0x10 5 32 1 32 10 36 28.5 23 DP28
5. Connector type and wire sequence requirements 10L16-0.31x5 10 16 0.31 4.96 5 8 8 18 DP30
5L32-0.8x10 5 32 0.8 25.6 10 29.5 28.5 23 DP31

17 PA Probes PA Probes 18
Laterally Focused Array Series Immersion Series

Features Features
The element is bent in the length direction to form focused beam on secondary axis Excellent waterproof performance within 1m underwater, acoustic impedance matches well with water
Can be used for automatic / semi-automatic scanning of pipes with diameter of 20mm-115mm in combination with Easy coupling to multiple surfaces
Doppler scanner
Corrosion resistant stainless steel housing
Combined with automatic system for online detection

DP7
DP29

DP9 DP8

Specifications and Dimensions


Specifications and Dimensions Casing Dimensions
Active
Frequency Pitch Elevation Case
Model Elements Aperture Long (L) Width (W) Height (H)
Casing Dimensions (MHZ) (mm) (mm) Type
Active (mm) mm mm mm
Frequency Pitch Elevation Case
Model Elements Aperture Long (L) Width (W) Height (H)
(MHZ) (mm) (mm) Type
(mm) mm mm mm
7.5S64-0.6x10 7.5 64 0.6 38.4 10
42.5 28.5 24.44 DP7
15S64-0.6x10 15 64 0.6 38.4 10
7.5S32-0.25x10 7.5 32 0.25 8 10
24.64 22 10 DP8
7.5S16-0.5x10 7.5 16 0.5 8 10
2.5S16-0.5x10 2.5 16 0.5 8 10 25 22 14 DP9
5S32-0.6x10 5 32 0.6 19.2 10 23 28.5 23 DP29

19 PA Probes PA Probes 20
DLA/DMA Series Water Bag Probe Series
Features
Features
When using a water bag wedge, there is no transverse wave or multiple
The probe is designed in a pulse and receive mode, which greatly optimizes the surface resolution wave impact compared to conventional wedges
of the workpiece to be tested and has a very small surface blind area It has a replaceable flexible coupling surface that is suitable for coupling
on different curved surfaces, and the detection process will not cause
Compared with conventional dual-crystal probe, it has larger coverage, better imaging effect and better signal-to-noise ratio
damage to the surface of the workpiece
The clutter absorption has been optimized, interference has been
reduced, and the signal-to-noise ratio has been improved

Specifications and Dimensions


Casing Dimensions
Active
Frequency Pitch Elevation Case
Model Elements Aperture Long (L) Width (W) Height (H)
(MHZ) (mm) (mm) Type
(mm) mm mm mm
4L128-0.8×10 4 128 0.8 102.4 10 120 36 25 WD83
5L128-0.6×10 5 128 0.6 76.8 10 94 36 25 WD94

Bolt Probe Series


Features
Specifications and Dimensions Suitable for bolt defect detection in different fields such as bridges, high-
speed rail, wind power, etc.
Casing Dimensions
Active Active Can perform in-service testing on working state bolts without disassembling
Frequency Pitch Pitch Case
Model Elements Aperture Aperture Long (L) Width (W) Height (H)
(MHZ) Px(mm) Py(mm) Type High efficiency: Whole bolt defect detection can be completed by a single
Lx(mm) Ly(mm) mm mm mm coupling
2.25DM7x4-2.71x3.0 2.25 56 2.71 3 18.97 12 33.8 16 20 DP10 Bolt detection range: M20-M100
4DM16x2-1.0x3.0 4 64 1 3 16 6 28.5 10.9 20 DP11
5DL16-0.75x5 5 32 0.75 / 12 5 24 23.6 20 DP12
Specifications and Dimensions
2.25DL32-0.6x12 2.25 64 0.6 / 19.2 12 33.8 17 25 DP13
4DL32-1.0x10 4 64 1 / 32 10 46 16 20 DP14 Casing Dimensions
Inner Outer Bolt
Frequency Pitch Case
Model Elements Diameter Diameter Diameter Diameter (φ) Height (H)
(MHZ) (mm) Type
(mm) (mm) (mm) mm mm

21 PA Probes PA Probes 22
Matrix Array Series Wedge Integrated Series
Features
Features
Three dimensional imaging
Sound beam can be deflected in each direction Permanent fixation of elements and wedge
Built-in wedge or delay line. Smaller size, convenient to use
Smaller spatial focus, more concentrated energy and better
in a narrow space
signal-to-noise ratio
With its own wedge, direct angle scanning can be carried out

Specifications and Dimensions


Specifications and Dimensions
Casing Dimensions
Casing Dimensions Wedge Active
Active Active Frequency Pitch Elevation Case
Frequency Pitch Pitch Case Model Elements Angle Aperture Long (L) Width (W) Height (H)
Model Elements Aperture Aperture Long (L) Width (W) Height (H) (MHZ) (mm) (mm) Type
(MHZ) Px(mm) Py(mm) Type (°) (mm) mm mm mm
Lx(mm) Lx(mm) mm mm mm
5L12-0.5x6 5 12 0.5 36 6 6 24.87 13 10.35 DP16
5M8x8-1.0x1.0 5 64 1 1 8 8 21 13 28 DP15

Wheel Series Concave Series DP24

Features Features
With water storage coupling system, good coupling effect Excellent waterproof performance within 1m underwater, acoustic
Very low attenuation tire material impedance matches well with water
Optional with angle adjustment block, can obtain incident angle of 0 ° - 20 ° Especially suitable for automatic on-line detection
It can match automatic scanning device, which is suitable for detection of Automatic / semi-automatic detection of pipeline corrosion and thickness
large-area flat or micro curved surface measurement with Doppler scanner

DP23
Specifications and Dimensions Specifications and Dimensions
Casing Dimensions
Active Casing Dimensions
Frequency Pitch Elevation Case Active
Model Elements Aperture Long (L) Width (W) Height (H) Frequency Pitch Radius Elevation Case
(MHZ) (mm) (mm) Type Model Elements Aperture Long (L) Width (W) Height (H)
(mm) (MHZ) (mm) R(mm) (mm) Type
mm mm mm (mm) mm mm mm
5L64-0.8x6.4 5 64 0.8 51.2 6.4 7.5C32-0.5x10 7.5 32 0.5 16 11 10 28 30 25 DP23
128 25 25 E96
10L64-0.8x6.4 10 64 0.8 51.2 6.4 5C128-0.95x12 5 128 0.95 121.6 50 12 120 107 23 DP24

23 PA Probes PA Probes 24
Flexible Array Series Photoacoustic Probe Series
Features Features
The primary direction of the probe can be bent with For receiving and organizing ultrasonic signals in
surface shape of the workpiece, the curvature is photoacoustic / thermoacoustic imaging
variable with a minimum bending radius 30mm Optimize receiving bandwidth
With a minimum thickness of 3mm, the probe can Optimize electromagnetic shielding
enter the narrow space for detection
Suilable for corrosion / thickness measurement of
DP26
pipes and bars combined with Doppler scanners

Specifications and Dimensions


Casing Dimensions
Active
Frequency Pitch Elevation Case
Model Elements Aperture Long (L) Width (W) Height (H)
(MHZ) (mm) (mm) Type
(mm) mm mm mm
7.5S64-0.5x10 7.5 64 0.5 32 10 80 19 4 DP26
7.5S64-1.0x10 7.5 64 1 64 10 150 29 4 DP27

Power Probe Series


Features for Single Element
Frequency: 0.5-10MHz

High Temperature Series Aperture: 1-120mm


Focusing number: F > 0.5
Sound intensity in focal area > 5000W / cm ²
Features High efficiency, low heating, allowing continuous
wave excitation
The overall temperature resistance of the probe, combined Customized mechanical structure, lead and MRI
with the high-temperature resistant wedge, it can continuously compatible
detect the workpiece with the surface temperature of 150 °C
It can be matched with 0° and angled high temperature Power Ultrasonic Laterally Focused Probe
wedge Features for Array Probe
DP5 DP28
Frequency: 0.5-3MHz
Specifications and Dimensions The array configuration includes linear array, circular array, matrix and multi-channel array
Active
Casing Dimensions Array element arrangement includes periodic, aperiodic, random array and customized arrangement
Frequency Pitch Elevation Case
Model Elements Aperture Long (L) Width (W) Height (H)
(MHZ) (mm) (mm) Type
(mm) mm mm mm
5L64-1.0x10 5 64 1 64 10 70 28.5 23 DP5
5L32-1.0x10 5 32 1 32 10 36 28.5 23 DP28

25 PA Probes PA Probes 26
Air-coupling Probes Other Special Probes
According to the needs of on-site detection, we can develop special customized probes for customers. Some customized probes
Features
are listed below. Doppler is your best choice for solutions for difficult scenes.
Non-contact air coupled ultrasound (ACU)
High sensitivity and high signal to noise ratio
Optional 60dB built-in amplifier, the amplifier is USB
interface
Customizable series for focusing and working in water
mist environment

Specifications and Dimensions


Active
Frequency
Models Aperture Focus Standard Interface Operating Mode
(KHZ)
(mm)
Multi circular sector probe Self-focusing concave array probe Replaceable soft protective film probe
AB0.25C24NF-T 250 24 NO Emission
AB0.25C24NF-R 250 24 NO Receive
AB0.42C24NF-T 420 24 NO Emission
BNC
AB0.42C24NF-R 420 24 NO Receive
AB1C13NF-T 1000 13 NO Emission
AB1C13NF-R 1000 13 NO Receive

Annular taper probe Multi connector probe Near wall probe

Inner-through annular self-focusing Inner-through annular convex Inner-through annular convex


convex array probe array probe matrix probe
Experiment of 250kHz Air-Coupled Probe
Penetrating 64mm Refractory Brick

27 PA Probes PA Probes 28
Instructions for Phased Array Probe
A layer of blue protective film is pasted on the probe surface to avoid scratches during transportation. Please tear off the protective
film before use, otherwise it will affect the performance of the probe
Do not forcibly plug and unplug the connector to avoid pin damage
Use the probe carefully to avoid impact by external force
When the probe is not in use, it shall be sealed and stored, such as in the original suitcase, so as not to be affected by environment
The application scenarios of different types of probes are determined according to the specific application standards. The solutions
of different scenarios are welcome to inquire. Website: www.cndoppler.com, Email: [email protected]

Integrated self-focusing concave probe Circular array probe

Warranty Description

The warranty period of Doppler phased array probe is generally one year, and the warranty scope does not include damage or wear
caused by misuse or accident, such as:

Incorrect assembly method


Incorrect use, including but not limited to the impact of the probe surface, unauthorized disassembly, etc.
For use in an environment outside the allowable range, the storage temperature range of the probe is generally - 30 ° C to 50 ° C,
and the service temperature range is - 20 ° C to 50 ° C
The excitation voltage is too large. Generally, the maximum repetition frequency is 10 KHz, and the continuous operation is no more
than 5 KHz 100V (the details shall be subject to the probe test report)
Use of substandard couplant
Annular hollow focusing probe

General Index of Phased Array Probe


Options Doppler has strict quality standards for products, and the general indicators of products are as follows (according to JB / T 11731-2013
test standard):
The corrugated sleeve can protect the cable from corrosion and external impact
Nylon mesh sleeve can increase protection while maintaining the
flexibility of cable Sensitivity conformity ±2dB
Metal corrugated tube can enhance shielding and anti-interference Sensitivity difference between batches ±2dB
on the basis of protecting cable lines from corrosion and impact
resistance Service temperature -20°C to 50°C

Storage temperature -30°C to 50°C

High sound transmission soft protective film can be directly pasted


on the surface of phased array probe,so that the 0 ° wedge is not
needed for detection, the interference caused by multiple echoes on
the lower surface of the wedge is effectively eliminated, and the
detection cost is effectively reduced

29 PA Probes PA Probes 30
Connectors
PHASED ARRAY Doppler provides compatible connectors for all kinds of Phased Array Probes in the market, such as T1, P1, J1, H1, D1, D2, D3, M1, etc.
Probes Accessories

Wedges
T1: QLC-260P P1: I-PEX 30056 J1: D38999/26FF35SN
Features
Generally, it is used for SW or LW detection with an angle
between 30 ° and 70 °, providing refraction angles in standard
steel such as 0 °, 45 °, 55 ° and 60 °
Composite anti-wear screws can be used on easily scratched
surfaces D1: DL-156P D2:DL-260P H1: Hypertronics
High temperature wedge is used in high temperature
environment and can withstand high temperature of 260 °C
Wedge shape and parameters can be customized according
to customer requirements Anti Wear Wedge Water Wedge
Adapters & Extension Cables
The Doppler phased array ultrasound probe connector adapter box can be arbitrarily switched between T1, P1, J1, H1, D1, D2, D3,
M1 and other interfaces, and can be customized according to customer requirements.

Dual Array Wedge Angle Wedge 0° Wedge High Temperature Wedge

Specifications and Dimensions T1(Male)-J1(Female) T1(Male)-P1(Female) T1(Male)-H1(Female) P1(Male)-T1(Female)


J1(Probe)-T1(Instrument) P1(Probe)-T1(Instrument) H1(Probe)-T1(Instrument) Integrated Adapter Box
Wedge Dimensions
Probe Refraction
Wedge Type Wedge Model Long(L) Width(W) Height(H) Wedge Angle
Type Angle
mm mm mm
0°Wedge SDP3-N0L-H DP3 0°LW 48 30 20 0°
Angle Wedge SDP2-N55S-IH DP2 55°SW 41 30 26.64 36°
Anti Wear Wedge SDP2-N55S-IHC-AOD326 DP2 55°SW 41 30 27.29 36°(φ326mm)
Dual array Wedge SDP11-N55L-IHC(TR,roofangle3.7°,F=15) DP11 55°LW 30 40 14.96 18.7°
High temperature Wedge SDP28-N55S-IH(HT) DP28 55°SW 64 44 34 39.5°
Water Wedge SDP8-N65L-IH-AOD270 DP8 65°LW 23.96 22 13.12 36°(φ270mm)

31 PA Probes PA Probes 32
CONVENTIONAL
UT Probes

UT Probes Doppler designed a series of standard probes, customized probes and relevant accessories, in total more than 4000 models. Probes are
widely used in aerospace, nuclear power, oil and gas, mechanical manufacturing, shipping industry, railway transportation, medicals and so
on, and used on a variety of projects around the world. With more than 10 years transducer design experiences and keep improving
manufacturing process to ensure high performance and reliability of products. Doppler keep bringing in talents, investing in R&D, testing and
production facilities. From ultrasonic field distribution to transducer stack up design, Doppler keep innovating and progressing to bring better
products and services to clients.
This mannul collects most standardized transducer products, you can find almost all models you need. For customized products or unsolving
difficult subjects, our application and transducer especialists are very pleased to help to find the viable solutions.

Instruction of Conventional UT Probes


Ultrasonic Probe is the most essential part of ultrasonic detection systems, to choose the right probe can ensure a smooth detection
work and accuracy of test results
Doppler provides three different kinds of performance probes, with unique application and performance characteristics
Below shows transmitter, configuration, cable, crystal frequency, crystal size etc., characteristics and applications of three types of
probes

PL-Universal Series
Applications
General inspection environments

Features
With appropriate sensitivity and resolution
Longer duration of wave, typically at 3~5 cycles
Lower bandwidth, typically at 30~50%

UT Probes 34
PH-Short Pulsing Series Probe Data Sheet
Applications Each transducer sold by DOPPLER has undergone strict testing and certification with reliable detection equipment and stable testing
Ideal for precise thickness measurement, near surface environment. The data sheet can truly and effectively reflect the performance of the transducer, which contains basic parameters that need
detection environments to be paid attention to in daily use, as well as a large number of characteristic parameters. It helps users to make comparing and
researching of the probes characteristics.
Features
Excellent vertical and horizontal resolutions
Tiny blind spot width of initial pulse
Less Sensitivity than PL and C Series Data Type Description
Shorter duration of wave, typically at 1.5~2 cycles CN Complied to Chinese GB/T 27664.2 testing standards
Higher Bandwidth, typically at 80~110%
EN Complied to European EN ISO 22232-2 testing standards
AT Complied to North America ASTM E-1065 testing standards

CS Any probe other than "CN", "EN" and "AT", providing echo and spectrum diagram, center frequency, pulse
width, bandwidth, sensitivity and other important data
For twin crystal longitudinal wave angle probes, analysis relationship between angles, focal depth and focal
LFA
points, center frequency, bandwidth, sensitivity and relevant important data

C-Composite Series DGS


Provide probe DGS curve (to be ordered separately) to describe the relationship between distance, gain and
equivalent size for regular reflector

Applications
High penetration power and high SNR for coarse-grained,
fiber-reinforced composite materials

Features
1-3 piezo - composite crystal
Higher sensitivity to PL and PH series
Shorter duration of wave, typically at 2~2.5 cycles
Higher bandwidth, typically at 70~110%
Low acoustic impedance composites enable probes better
matching with low acoustic impedance medium such as water, plastics, etc.

CN EN

35 UT Probes UT Probes 36
Contact Probe - Wear Resistant Probes
A single crystal transducer, sound wave vertical incidence and direct contact.

Features
Wear resistant stainless steel housing
Wear resistant front end protective layer, long service life
Good match acoustic impedance with most metals
3 types of performance to meet the cast majority of testing requirements

“PL” Universal Series, “PH” Short Pulsing Series, “C” Composite Series

AT CS Applications
Simple structure of metals
Large plates, bars, forgings, metals and non-metals
Small tanks, pipes, castings, bars
Sandwich and laminated structures
Materials velocity and characteristics
Coarse grain or high attenuation materials

LFA DGS

37 UT Probes UT Probes 38
European Standard - N2 European Standard - N3
Microdot(L5), Lemo 00(C5), and Lemo 01(C9) side mounting connectors, for above φ5 can be customized as top mounting connector Low height probes, suitable for narrow and limited detection environments
Lemo 00 (C5) side mounting connector, with handle bar

Probe Dimensions
Nominal Element Size A B C D E
Connector Direction Probe Dimensions
mm in mm in mm in mm in mm in mm in
Nominal Element Size A B C D
10 0.375 20.0 0.79 42.5 1.67 24.0 0.94 14.0 0.55 2.0 0.08 Lemo-00 / Side Mounting
mm in mm in mm in mm in mm in
24 0.94 30.0 1.18 59.5 2.34 45.0 1.77 29.0 1.14 2.5 0.10 Lemo-1 / Side Mounting
10 0.38 19 0.75 16 0.63 17 0.67 20 0.79
20 0.79 29 1.14 16 0.63 27 1.06 20 0.79

Probe Dimensions
Probe Specification
Nominal Element Size A B C
Connector Direction Frequency Nominal Element Size Model
mm in mm in mm in mm in
Housing Dimensions MHZ mm in PL PH
5 0.20 9.0 0.35 10.0 0.39 15.0 0.59 Microdot / Side Mounting
1 10 0.38 N3-1P10 N3-1P10-H
(10/24mm Crystal Diameter)
10 0.38 N3-2P10 N3-2P10-H
Housing Dimensions 2
20 0.79 N3-2P20 N3-2P20-H
(5mm Crystal Diameter) 10 0.38 N3-4P10 N3-4P10-H
4
20 0.79 N3-4P20 N3-4P20-H
10 0.38 N3-5P10 N3-5P10-H
5
20 0.79 N3-5P20 N3-5P20-H
10 10 0.38 / N3-10P10-H

Probe Specification
Frequency Nominal Element Size Model N2-2P24
MHz mm in PL PH
10 0.375 N2-1P10 N2-1P10-H N2-4P10
1 N3-5P20-H
24 0.94 N2-1P24 N2-1P24-H N3-4P10
10 0.375 N2-2P10 N2-2P10-H
2
24 0.94 N2-2P24 N2-2P24-H
10 0.375 N2-4P10 N2-4P10-H
4
24 0.94 N2-4P24 N2-4P24-H
5 0.20 N2-5P5 N2-5P5-H
5
10 0.375 N2-5P10 N2-5P10-H
10 5 0.20 / N2-10P5-H

N2-10P5-H

39 UT Probes UT Probes 40
North America Standard - N4 North America Standard - N5
Low height probes, suitable for narrow and limited detection environments
Large crystal diameter to ensure high sensitivity of probe, and wider coverage area of detection Lemo 00(C5) side mounting connector, with handle bar
BNC(Q9) side mounting connector, can be customized as top mounting connector Can be customized as top mounting connector

Probe Specification Probe Dimensions


Frequency Nominal Element Size Model Nominal Element Size A B C
MHz mm in PL PH C mm in mm in mm in mm in
 Probe Dimensions
13 0.50 N5-1P13 N5-1P13-H N5-1C13 3 0.125 6.5 0.26 7.5 0.3 10 0.4
Nominal Element Size A B C D
1 19 0.75 N5-1P19 N5-1P19-H / 6 0.25 9 0.35 10.5 0.41 13 0.51
mm in mm in mm in mm in mm in
25 1.00 N5-1P25 N5-1P25-H / 10 0.375 14 0.55 15 0.59 14 0.55
13 0.50 20 0.79 29.5 1.16 36 1.42 23 0.91
6 0.25 N5-2.25P6 N5-2.25P6-H N5-2.25C6 13 0.50 17 0.66 18 0.71 16 0.64
19 0.75 28 1.10 38 1.48 36 1.42 31 1.22
10 0.375 N5-2.25P10 N5-2.25P10-H N5-2.25C10 19 0.75 24 0.95 25 0.97 16 0.64
25 1.00 32 1.26 41.5 1.63 36 1.42 35 1.38
2.25 13 0.50 N5-2.25P13 N5-2.25P13-H N5-2.25C13 25 1.00 29 1.15 30 1.18 16 0.64
29 1.125 38 1.50 41.5 1.63 36 1.42 41 1.61
19 0.75 N5-2.25P19 N5-2.25P19-H /
25 1.00 N5-2.25P25 N5-2.25P25-H /
6 0.25 N5-3.5P6 N5-3.5P6-H N5-3.5C6
10 0.375 N5-3.5P10 N5-3.5P10-H N5-3.5C10
3.5 13 0.50 N5-3.5P13 N5-3.5P13-H /

Probe Specification 19 0.75 N5-3.5P19 N5-3.5P19-H /


Frequency Nominal Element Size Model 25 1.00 N5-3.5P25 N5-3.5P25-H /

MHz mm in PL PH C 6 0.25 N5-5P6 N5-5P6-H N5-5C6

19 0.75 / N4-0.5P19-H / 10 0.375 N5-5P10 N5-5P10-H N5-5C10


5
0.5 25 1.00 / N4-0.5P25-H / 13 0.50 N5-5P13 N5-5P13-H /

29 1.125 / N4-0.5P29-H / 19 0.75 N5-5P19 N5-5P19-H /


N4-0.5P29-H 6 0.25 N5-7.5P6 N5-7.5P6-H /
13 0.50 N4-1P13 N4-1P13-H N4-1C13
19 0.75 N4-1P19 N4-1P19-H / 7.5 10 0.375 N5-7.5P10 N5-7.5P10-H /
1
13 0.50 N5-7.5P13 N5-7.5P13-H /
N5-5P13-H
25 1.00 N4-1P25 N4-1P25-H / N4-1P25 N4-2.25P19 N5-10P10-H
29 1.125 N4-1P29 N4-1P29-H / 6 0.25 N5-10P6 N5-10P6-H /

13 0.50 N4-2.25P13 N4-2.25P13-H N4-2.25C13 10 10 0.375 N5-10P10 N5-10P10-H /

19 0.75 N4-2.25P19 N4-2.25P19-H / 13 0.50 N5-10P13 N5-10P13-H /


2.25 /
25 1.00 N4-2.25P25 N4-2.25P25-H / 3 0.125 N5-15P3-H / N5-10P6-H
15
29 常规超声探头产品
1.125 N4-2.25P29 N4-2.25P29-H / 6 0.375 / N5-15P6-H /

13 0.50 N4-3.5P13 N4-3.5P13-H / 20 3 0.125 / N5-20P3-H /

3.5 19 0.75 N4-3.5P19 N4-3.5P19-H / 25 3 0.125 / N5-25P3-H /

25 1.00 N4-3.5P25 N4-3.5P25-H /


13 0.50 N4-5P13 N4-5P13-H /
5 19 0.75 N4-5P19 N4-5P19-H /
25 1.00 N4-5P25 N4-5P25-H /
7.5 13 0.50 N4-7.5P13 N4-7.5P13-H / N4-10P13-H
10 13 0.50 N4-10P13 N4-10P13-H / N5-5P6

N5-2.25P10

41 UT Probes UT Probes 42
Contact Probe - Normal Incidence Shear Contact Probe - Protective Face Probes
Probe Specification
Nominal
Frequency Element Size Model
mm in
Wave Probes
MHz
0.5 25 1.00 SN0.5P25 Replaceable protective films, sound wave vertical incidence and direct contact with workpiece
13 0.50 SN1P13
1 19 0.75 SN1P19
The normal shear wave probe is a single-element transducer that directly contacts
25 1.00 SN1P25
the workpiece and generates transverse wave by vertical incidence.
10 0.375 SN2.25P10 Features
2.25
13 0.50 SN2.25P13
Provide soft film or wear-resistant cover for different applications
Applications 6 0.25 SN2.5P6
The soft film can reduce the effect of coupling on uneven or rough surfaces
2.5 10 0.375 SN2.5P10
Measurement of shear wave sound velocity of workpiece 13 0.50 SN2.5P13 The wear-resistant cover is suitable for rapid scanning on rough surfaces
Calculation of Young's modulus of elasticity and shear modulus 10 0.375 SN4P10 The front soft film and wear-resistant cover can be replaced to prolong the service life of the probe
4
Analysis of workpiece grain structure 13 0.50 SN4P13 For European standard only provides the soft film option, for the North America standard we can provide both the soft film
5
6 0.25 SN5P6 and wear-resistant cover
10 0.38 SN5P10

Features Applications
Incident vertically and generate shear waves inside the workpiece Probe Dimensions Simple structure of metals
Sensitivity is usually lower than that of LW straight probe Nominal Element Size A B C Large plates, bars, forgings, metals and non-metals
Low probe height, suitable for the situation of limited space mm in mm in mm in mm in Small tanks, pipes, castings, bars
High viscosity couplant is required, and the order code of 6 0.25 9 0.35 10.5 0.41 13 0.51
Sandwich and laminated structures
couplant is 6JS0124* 10 0.375 14 0.55 15 0.59 14 0.55
The polarization direction of shear wave is consistent with the 13 0.50 17 0.66 18 0.71 16 0.64
interface direction 19 0.75 24 0.95 25 0.97 16 0.64

Probe interface is side mounted Microdot by default, top 25 1.00 29 1.15 30 1.18 16 0.64 European Standard PF1
mounting can be customized
Probe Dimensions
Nominal Element Size A B C D E
Connector Direction
mm in mm in mm in mm in mm in mm in
10 0.375 20.0 0.79 42.5 1.67 24.0 0.94 14.0 0.55 1.5 0.06 Lemo-00/Side Mounting
SN5P13 PF1-2P24
24 0.94 30.0 1.18 59.5 2.34 45.0 1.77 29.0 1.14 1.5 0.06 Lemo-1/Side Mounting

SN5P6

PF1-4P10
Probe Specification
Frequency Nominal Element Size Model
MHz mm in PL
10 0.375 PF1-2P10
2
24 0.94 PF1-2P24
10 0.375 PF1-4P10
4
SN2.25P10 24 0.94 PF1-4P24
*In order to obtain the best coupling effect between probe and workpiece,
10 0.375 PF1-5P10
we suggest placing a small amount of high viscosity coupling agent on the 5
24 0.94 PF1-5P24
surface of the probe and scraping the coupling agent into thin sheets with a PF1-2P10
blade or card; Couple the probe to the workpiece and rotate it while
pressing down.

43 UT Probes UT Probes 44
MembranceSpecification Dimensions(Soft Film)
Nominal Element Size Nominal Element Size A B C D
Type Model 3WK0564
mm in mm in mm in mm in mm in mm in
2QT0150 10 0.375 3WK0545 13 0.50 25 0.98 28.5 1.12 41 1.61 22 0.87
Soft Film
3SS0058 24 0.94 19 0.75 33 1.30 36.5 1.44 41 1.61 30 1.18
Threaded 3WK0545 10 0.375 25 1.00 38 1.50 40.5 1.59 41 1.61 34 1.34
Collar 3WK0564 24 0.94

Dimensions(Wear-Resistant Cover)
2QT0150 Nominal Element Size A B C D
mm in mm in mm in mm in mm in
3SS0058 13 0.50 25 0.98 28.5 1.12 42 1.65 22 0.87
19 0.75 33 1.30 36.5 1.44 42 1.65 30 1.18
25 1.00 38 1.50 40.5 1.59 42 1.65 34 1.34

Fittings(Soft Film Probe) 2QK5892


North America Standard PF2 Type Model
Nominal Element Size
mm in
2QK5891 2QK5890
2QT0242 13 0.500
The probe interface is side mounted BNC by default, and the top mounted BNC can be customized.
Soft Film 2QT0243 19 0.750
2QT0244 25 1.00
2QK5890 13 0.500
Threaded
Collar 2QK5891 19 0.750
2QK5892 25 1.00
Nominal
Frequency Element Size Models PF2-2.25P19 PF2-2.5P25N
2QT0242
MHz mm in Soft Film Wear-Resistant Cover
13 0.5 PF2-1P13 PF2-1P13N
1 19 0.75 PF2-1P19 PF2-1P19N 2QT0244
25 1.0 PF2-1P25 PF2-1P25N
13 0.5 PF2-2.25P13 PF2-2.25P13N
2.25 19 0.75 PF2-2.25P19 PF2-2.25P19N
25 1.0 PF2-2.25P25 PF2-2.25P25N
Fittings(Wear-Resistant Cover Probe) 2ZT0393
Nominal Element Size
2ZT0392
13 0.5 PF2-3.5P13 PF2-3.5P13N Type Model
mm in
3.5 19 0.75 PF2-3.5P19 PF2-3.5P19N
2ZT0391 13 0.500
25 1.0 PF2-3.5P25 PF2-3.5P25N Wear-Resistant
2ZT0392 19 0.750
13 0.5 PF2-5P13 PF2-5P13N Cover
2ZT0393 25 1.00
5 19 0.75 PF2-5P19 PF2-5P19N
25 1.0 PF2-5P25 PF2-5P25N

2ZT0391
PF2-5P13 PF2-1P13N

45 UT Probes UT Probes 46
Contact Probe - Dual Element (TR) Probes European Standard
Independent transmit and receive crystals, and creates a creates certain focal length in workpiece.
PL Series is the default probe type
Lemo 00(C5) side mounting connector

Features Applications
Probe Specification
No initial pulse dead zone effects Corrosion monitoring Frequency Nominal Element Size Focal Length Model
Less scattering, higher SNR in high attenuation material Residual wall measurement MHz mm in mm in PL C
Good coupling on curved and rough surfaces Coating measurement 1 Φ21/2 Φ0.83 20 0.79 DA1P21FS20 DA1C21FS20
Two types of performance probes can meet most of detection needs Near surface defects detection 2 Φ8/2 Φ0.314 6 0.24 DA2P8FS6 DA2C8FS6
Cracks, porosities, impurity and porosity detection of forgings 2 Φ11/2 Φ0.43 8 0.31 DA2P11FS8 DA2C11FS8
“PL” Universal Series,“C ” Composite Series High attenuation material detection 2 3.5 x 10 0.14 x 0.39 10 0.39 DA2P3.5 x 10FS10 DA2C3.5 x 10FS10
2 3.5 x 10 0.14 x 0.39 18 0.71 DA2P3.5 x 10FS18 DA2C3.5 x 10FS18
2 7 x 18 0.28 x 0.71 15 0.59 DA2P7 x 18FS15 DA2C7 x 18FS15
2 7 x 18 0.28 x 0.71 30 1.18 DA2P7 x 18FS30 DA2C7 x 18FS30
4 Φ8/2 Φ0.314 6 0.24 DA4P8FS6 DA4C8FS6
4 3.5 x 10 0.14 x 0.39 10 0.39 DA4P3.5 x 10FS10 DA4C3.5 x 10FS10
4 3.5 x 10 0.14 x 0.39 18 0.71 DA4P3.5 x 10FS18 DA4C3.5 x 10FS18
4 6 x 20 0.24 x 0.79 12 0.47 DA4P6 x 20FS12 DA4C6 x 20FS12
4 6 x 20 0.24 x 0.79 25 0.98 DA4P6 x 20FS25 DA4C6 x 20FS25
5 Φ8/2 Φ0.314 3 0.12 DA5P8FS3 DA5C8FS3
5 Φ9/2 Φ0.35 10 0.39 DA5P9FS10 DA5C9FS10
5 Φ9/2 Φ0.35 25 0.98 DA5P9FS25 DA5C9FS25
10 Φ5/2 Φ0.2 3 0.12 DA10P5FS3 DA10C5FS3

DA4P6X20FS12

DA4P3.5X10FS18

DA5P9FS10

47 UT Probes UT Probes 48
North America Standard
Probe Dimensions
Nominal Element Size A B C D E Connector Low height probes, suitable for narrow and limited detection environments
mm in mm in mm in mm in mm in mm in Direction Side mounting with 1.8 meter cable length, cable end with Lemo 01(C9), or BNC(Q9) connectors(optional)
Φ9/2 Φ0.35 20.0 0.79 49.0 1.93 24.5 0.96 12.0 0.47 8.0 0.31
Lemo-00/
Φ11/2 Φ0.43 Side Mounting
20.0 0.79 49.0 1.93 24.5 0.96 16.5 0.65 8.0 0.31
3.5 x 10 0.14 x 0.39
Probe Specification
Nominal Model
Frequency
Element Size Cable End with BNC Cable End with Lemo 01
Probe Dimensions
Nominal Element Size A B C D E MHz mm in PL C PL C
Connector
mm in mm in mm in mm in mm in mm in Direction 6 0.25 DA3-2.25P6-B DA3-2.25C6-B DA3-2.25P6-1 DA3-2.25C6-1

Φ21/2 Φ0.83 2.25 10 0.375 DA3-2.25P10-B DA3-2.25C10-B DA3-2.25P10-1 DA3-2.25C10-1


Lemo-00/ 13 0.50 DA3-2.25P13-B DA3-2.25C13-B DA3-2.25P13-1 DA3-2.25C13-1
6 x 20 0.24 x 0.79 30.0 1.18 65.3 2.57 44.5 1.75 28.5 1.12 7.5 0.30
Side Mounting
7 x 18 0.28 x 0.71 6 0.25 DA3-3.5P6-B DA3-3.5C6-B DA3-3.5P6-1 DA3-3.5C6-1
3.5 10 0.375 DA3-3.5P10-B DA3-3.5C10-B DA3-3.5P10-1 DA3-3.5C10-1
13 0.50 DA3-3.5P13-B DA3-3.5C13-B DA3-3.5P13-1 DA3-3.5C13-1
6 0.25 DA3-5P6-B DA3-5C6-B DA3-5P6-1 DA3-5C6-1
5 10 0.375 DA3-5P10-B DA3-5C10-B DA3-5P10-1 DA3-5C10-1
13 0.50 DA3-5P13-B DA3-5C13-B DA3-5P13-1 DA3-5C13-1
7.5 6 0.250 DA3-7.5P6-B DA3-7.5C6-B DA3-7.5P6-1 DA3-7.5C6-1
10 6 0.25 DA3-10P6-B DA3-10C6-B DA3-10P6-1 DA3-10C6-1

Probe Dimensions Probe Dimensions


Nominal Element Size Connector Nominal Element Size Connector Probe Dimensions
mm in Direction mm in Direction Nominal Element Size A B C D
Microdot/ Microdot/ mm in mm in mm in mm in mm in
Φ8/2 0.314 Φ5/2 0.20
Side Mounting Side Mounting
6 0.25 12.0 0.47 16.5 0.65 9.5 0.37 22.0 0.87
10 0.375 16.0 0.63 16.5 0.65 12.0 0.47 22.0 0.87
13 0.50 19.5 0.77 17.0 0.67 15.5 0.61 22.0 0.87

DA3-5P13-1

DA3-2.25C10-1

DA3-10P6-1

DA5P8FS3

49 UT Probes UT Probes 50
Contact Probe - Angle Beam Probes and Wedges European Standard
Refracting ultrasonic beams and generate shear or longitudinal waves to workpiece through a fix angle of delay line. PL Series is the default probe type
Microdot(L5), Lemo 00(C5), and Lemo 01 (C9) top side mounting connectors,
Features all models can be customized for top mounting except size 3*4mm

Ergonomic design, with durable cast housing


Customizable any theoretical angles of ultrasound
Probe face can be processed into different shapes to ensure good coupling with workpiece:
Probe Dimensions
AID(Axial Inside Diameter) CID(Circumferential Inside Diameter)
Nominal Element Size A B C
AOD(Axial Outside Diameter) COD(Circumferrential Outside Diameter) Connector Direction
mm in mm in mm in mm in
Three types of performance can meet the most of detection needs:
3x4 0.12 x 0.16 16.0 0.60 7.0 0.30 7.0 0.30 Microdot/Top Mounting

“PL ” Universal Series, “PH ” Short Pulsing Series, “C ” Composite Series

Applications
For welding inspection
Pipes, pressure vessels, storage tanks Probe Dimensions
Turbine blades Nominal Element Size A B C
Connector Direction
Wheel axles, castings, forgings mm in mm in mm in mm in

Bond testing 5x 5 0.2 x 0.2 16.0 0.63 8.0 0.31 11.5 0.45 Microdot/Side Mounting

Railway wheels and tracks

Probe Dimensions
Nominal Element Size A B C
Connector Direction
mm in mm in mm in mm in
8x9 0.31 x 0.35 27.0 1.10 16.6 0.65 22.0 0.86
Lemo-00/Side Mounting
14x14 0.55 x 0.55 36.0 1.40 21.0 0.80 30.5 1.20
20x22 0.79 x 0.87 54.0 2.10 32.0 1.30 44.0 1.70 Lemo-1/Side Mounting

51 UT Probes UT Probes 52
Frequency ax b
Probe Specification
β(°) Near Field Model
North America Standard A3
MHz mm in Steel mm in PL C A4P20X22A45
1 20 x 22 0.79 x 0.87 45 45 1.8 A1P20 x 22A45 A1C20 x 22A45
The probe and delay line can be disassembled quickly
1 20 x 22 0.79 x 0.87 60 45 1.8 A1P20 x 22A60 A1C20 x 22A60 Delay lines are divided into two types: standard cutting edge and short cutting edge
1 20 x 22 0.79 x 0.87 70 45 1.8 A1P20 x 22A70 A1C20 x 22A70 The corresponding thread is 1/2-28 and 5/8-24 for probes and delay line with diameter 10mm and 13mm
2 8x9 0.31 x 0.35 38 15 0.6 A2P8 x 9A38 A2C8 x 9A38 separately. OP type can be indicated when ordering with corresponding thread 9/16-24 and 11/16-24
2 8x9 0.31 x 0.35 45 15 0.6 A2P8 x 9A45 A2C8 x 9A45 Microdot top mounting connector
2 8x9 0.31 x 0.35 60 15 0.6 A2P8 x 9A60 A2C8 x 9A60
2 8x9 0.31 x 0.35 70 15 0.6 A2P8 x 9A70 A2C8 x 9A70 Probe Dimensions
2 8x9 0.31 x 0.35 90 15 0.6 A2P8 x 9A90 A2C8 x 9A90 Nominal Element Size A B Connector
2 14 x 14 0.55 x 0.55 45 39 1.5 A2P14 x 14A45 A2C14 x 14A45 mm in mm in mm in Direction

2 14 x 14 0.55 x 0.55 60 39 1.5 A2P14 x 14A60 A2C14 x 14A60 6 0.25 11 0.42 14 0.56
Microdot/
2 14 x 14 0.55 x 0.55 70 39 1.5 A2P14 x 14A70 A2C14 x 14A70 10 0.375 14 0.55 15 0.58
Top Mounting
2 20 x 22 0.79 x 0.87 38 92 3.6 A2P20 x 22A38 A2C20 x 22A38 13 0.50 18 0.70 17 0.65
2 20 x 22 0.79 x 0.87 45 92 3.6 A2P20 x 22A45 A2C20 x 22A45
2 20 x 22 0.79 x 0.87 60 92 3.6 A2P20 x 22A60 A2C20 x 22A60
Probe Specification
2 20 x 22 0.79 x 0.87 70 92 3.6 A2P20 x 22A70 A2C20 x 22A70
Frequency Nominal Element Size Model Threads
4 8x9 0.31 x 0.35 38 30 1.2 A4P8 x 9A38 A4C8 x 9A38 A5P5X5A70
MHz mm in PL PH C in
4 8x9 0.31 x 0.35 45 30 1.2 A4P8 x 9A45 A4C8 x 9A45
1 13 0.50 A3-1P13 A3-1P13-H A3-1C13 5/8-24
4 8x9 0.31 x 0.35 60 30 1.2 A4P8 x 9A60 A4C8 x 9A60
4 8x9 0.31 x 0.35 70 30 1.2 A4P8 x 9A70 A4C8 x 9A70 6 0.25 A3-2.25P6 A3-2.25P6-H A3-2.25C6 3/8-32
2.25 10 0.375 A3-2.25P10 A3-2.25P10-H A3-2.25C10 1/2-28
4 8x9 0.31 x 0.35 90 30 1.2 A4P8 x 9A90 A4C8 x 9A90
4 14 x 14 0.55 x 0.55 45 78 3.0 A4P14 x 14A45 A4C14 x 14A45 13 0.50 A3-2.25P13 A3-2.25P13-H A3-2.25C13 5/8-24

4 14 x 14 0.55 x 0.55 60 78 3.0 A4P14 x 14A60 A4C14 x 14A60 6 0.25 A3-3.5P6 A3-3.5P6-H A3-3.5C6 3/8-32
3.5 10 0.375 A3-3.5P10 A3-3.5P10-H A3-3.5C10 1/2-28
4 14 x 14 0.55 x 0.55 70 78 3.0 A4P14 x 14A70 A4C14 x 14A70
4 20 x 22 0.79 x 0.87 38 184 7.2 A4P20 x 22A38 / 13 0.50 A3-3.5P13 A3-3.5P13-H A3-3.5C13 5/8-24

4 20 x 22 0.79 x 0.87 45 184 7.2 A4P20 x 22A45 / 6 0.25 A3-5P6 A3-5P6-H A3-5C6 3/8-32

4 20 x 22 0.79 x 0.87 60 184 7.2 A4P20 x 22A60 / A2P14X14A70 5 10 0.375 A3-5P10 A3-5P10-H A3-5C10 1/2-28

4 20 x 22 0.79 x 0.87 70 184 7.2 A4P20 x 22A70 / 13 0.50 A3-5P13 A3-5P13-H A3-5C13 5/8-24

5 5x5 0.2 x 0.2 45 13 0.5 A5P5*5A45 A5C5*5A45 7.5 6 0.25 A3-7.5P6 A3-7.5P6-H A3-7.5C6 3/8-32

5 5x5 0.2 x 0.2 60 13 0.5 A5P5*5A60 A5C5*5A60 A4P8X9A45


5 5x5 0.2 x 0.2 70 13 0.5 A5P5*5A70 A5C5*5A70
5 14 x 14 0.55 x 0.55 45 100 3.9 A5P14 x 14A45 /
A3-2.25P13
5 14 x 14 0.55 x 0.55 60 100 3.9 A5P14 x 14A60 /
5 14 x 14 0.55 x 0.55 70 100 3.9 A5P14 x 14A70 /
6 3x4 0.12 x 0.16 45 7 0.27 A6P3*4A45 A6C3*4A45
6 3x4 0.12 x 0.16 60 7 0.27 A6P3*4A60 A6C3*4A60
6 3x4 0.12 x 0.16 70 7 0.27 A6P3*4A70 A6C3*4A70

A6P3X4A70
A3-5P10
A3-2.25P6


53 UT Probes UT Probes 54
Standard Delay Line Dimensions North America Standard A4
β(°) A B C D Threads Nominal Element Size
Model
Steel mm in mm in mm in mm in in mm in
The larger wafer size enables the detection of thicker workpieces
Φ6-45° 45 19.1 0.75 11.4 0.45 9.4 0.37 9.5 0.37 3/8-32
Φ6-60° 60 21.3 0.84 11.4 0.45 11.2 0.44 10.8 0.43 3/8-32 Delay lines are divided into SL and RL, among which RL series conforms to the requirements of AWS Specification D1.1
6 0.25
Φ6-70° 70 25.4 1.00 11.4 0.45 12.7 0.50 13.5 0.53 3/8-32 High temperature resistance series delay line can be customized
Φ6-90° 90 24.1 0.95 11.4 0.45 12.7 0.50 / / 3/8-32 The probe is equipped with a non - falling screw and delay line can be disassembled tool free
Φ10-45° 45 22.6 0.89 14 0.55 11.9 0.47 12.2 0.48 1/2-28 The probe interface is BNC top by default
Φ10-60° 60 26.4 1.04 14 0.55 14 0.55 12.8 0.50 1/2-28
10 0.375
Φ10-70° 70 30.2 1.19 14 0.55 14.7 0.58 17 0.67 1/2-28 Probe Specification
Φ10-90° 90 29.5 1.15 14 0.55 14.7 0.61 / / 1/2-28 Frequency Nominal Element Size Model
Φ13-45° 45 26.7 1.05 17.8 0.70 14 0.55 14.5 0.57 5/8-24 MHz mm in PL PH C
Φ13-60° 60 31.5 1.24 17.8 0.70 16.3 0.64 18.5 0.73 5/8-24 0.5 φ25 1 A4-0.5P25 A4-0.5P25-H /
13 0.5
Φ13-70° 70 35.8 1.41 17.8 0.70 17.3 0.68 20.5 0.81 5/8-24 φ13 0.5 A4-1P13 A4-1P13-H A4-1C13
Φ13-90° 90 35.5 1.39 17.8 0.70 18.5 0.73 / / 5/8-24 13x25 0.5x1 A4-1P13x25 A4-1P13x25-H A4-1C13x25
1
19x25 0.75x1 A4-1P19x25 A4-1P19x25-H /
φ25 1 A4-1P25 A4-1P25-H /
φ13 0.5 A4-2.25P13 A4-2.25P13-H A4-2.25C13
Short Delay Line Dimensions
13x25 0.5x1 A4-2.25P13x25 A4-2.25P13x25-H A4-2.25C13x25
β(°) A B C D Threads Nominal Element Size
Model 16x16 0.63x0.63 A4-2.25P16x16 A4-2.25P16x16-H A4-2.25C16x16
Steel mm in mm in mm in mm in in mm in 2.25 16x19 0.63x0.75 A4-2.25P16x19 A4-2.25P16x19-H A4-2.25C16x19
Φ6-45° 45 15.5 0.61 11.4 0.45 10.9 0.43 5.8 0.23 3/8-32 19x19 0.75x0.75 A4-2.25P19x19 A4-2.25P19x19-H /
Φ6-60° 60 18.0 0.71 11.4 0.45 12.2 0.48 6.8 0.27 3/8-32 6 0.25 19x25 0.75x1 A4-2.25P19x25 A4-2.25P19x25-H /
Φ6-70° 70 20.6 0.81 11.4 0.45 12.7 0.50 7.8 0.31 3/8-32 φ25 1 A4-2.25P25 A4-2.25P25-H /

Φ10-45° 45 21.6 0.85 14 0.55 15.2 0.60 8 0.31 1/2-28 φ13 0.5 A4-3.5P13 A4-3.5P13-H A4-3.5C13

Φ10-60° 60 25.4 1.00 14 0.55 17 0.67 9 0.35 1/2-28 10 0.375 13x25 0.5x1 A4-3.5P13x25 A4-3.5P13x25-H A4-3.5C13x25
3.5
Φ10-70° 70 28.4 1.12 14 0.55 17.5 0.69 1/2-28 19x25 0.75x1 A4-3.5P19x25 A4-3.5P19x25-H /
10 0.39
φ25 1 A4-3.5P25 A4-3.5P25-H /
Φ13-45° 45 26.2 1.03 17.8 0.70 17.8 0.70 8.5 0.33 5/8-24
φ13 0.5 A4-5P13 A4-5P13-H A4-5C13
Φ13-60° 60 30.2 1.19 17.8 0.70 18.8 0.74 10.8 0.43 5/8-24 13 0.5
13x25 0.5x1 A4-5P13x25 A4-5P13x25-H A4-5C13x25
Φ13-70° 70 34.0 1.34 17.8 0.70 20.1 0.79 12.2 0.48 5/8-24 5
19x25 0.75x1 A4-5P19x25 A4-5P19x25-H /
φ25 1 A4-5P25 A4-5P25-H /

Φ6-70° Φ13-60°
Probe Dimensions
Nominal Element Size A B C D
mm in mm in mm in mm in mm in
φ13 0.5 26 1.02 18.3 0.72 18 0.71 20.6 0.81
13x25 0.5x1 39 1.54 18.5 0.73 18 0.71 33.3 1.31
16x16 0.63x0.63 32 1.26 18.5 0.73 18 0.71 25.4 1.00
16x19 0.63x0.75 32 1.26 18.5 0.73 18 0.71 25.4 1.00
19x19 0.75x0.75 32 1.26 21.5 0.85 18 0.71 25.4 1.00
19x25 0.75x1 39 1.54 25.4 1.00 18 0.71 33.3 1.31
Φ10-45° Φ10-60° φ25 1 42 1.65 31 1.22 18 0.71 35.1 1.38

55 UT Probes UT Probes 56
β(°) A
SL Delay Line Dimensions
B C D Nominal Element Size
Contact Probe – Spot Weld Probes
Model
Steel mm in mm in mm in mm in mm in
SL-Φ13-45° 45 33.5 1.32 27.5 1.08 31 1.22 18 0.71 The spot welding probe is a single element transducer that contacts the workpiece through a specific water column.
SL-Φ13-60° 60 37.5 1.48 27.5 1.08 31 1.22 17.5 0.69
13 0.5
SL-Φ13-70° 70 40.5 1.59 27.5 1.08 31 1.22 17.5 0.69
SL-Φ13-90° 90 34 1.34 27.5 1.08 31 1.22 / /
SL-13x25-45° 45 35.5 1.40 40.5 1.59 33 1.30 19.5 0.77 Applications
SL-13x25-60° 60 37 1.46 40.5 1.59 33 1.30 17 0.67
13x25 0.5x1 Integrity measurement of spot welding quality in automobile or
SL-13x25-70° 70 44 1.73 40.5 1.59 34 1.34 21 0.83
other industries
SL-13x25-90° 90 34.5 1.36 40.5 1.59 30 1.18 / /
SL-19x25-45° 45 42 1.65 40.5 1.59 35 1.38 20.5 0.81
SL-19x25-60° 60 47 1.85 40.5 1.59 36 1.42 20 0.79
Features SWI20P4
19x25 0.75x1
SL-19x25-70° 70 53 2.09 40.5 1.59 38 1.50 23 0.91
The soft film can reduce the impact of coupling on uneven spot
SL-19x25-90° 90 50 1.97 40.5 1.59 38 1.50 / /
welding
SL-Φ25-45° 45 50 1.97 41.5 1.63 37 1.46 25 0.98
Different element sizes are used to measure the quality of spot
SL-Φ25-60° 60 56 2.20 41.5 1.63 38 1.50 24 0.94 SWI15P5
25 1 welding of different sizes
SL-Φ25-70° 70 63 2.48 41.5 1.63 38 1.50 28.5 1.12
The probe interface is side mounted Microdot by default
SL-Φ25-90° 90 63 2.48 41.5 1.63 38 1.50 / /

RL Delay Line Dimensions Probe Specification Structural Accessories


β(°) A B C D Nominal Element Size Frequency Nominal Element Size Model Model
Model SWI
Steel mm in mm in mm in mm in mm in MHz mm in Type Item Nominal Element Size (mm)
(water column)
RL-45° 45 45 1.77 31.8 1.25 54.5 2.15 15.8 0.62 16x16 0.63x0.63 2.5 0.10 SWI15P2.5 2.5 3 3.5 4 4.5 5 5.5 6

3 0.12 SWI15P3 Water column tube 2QT0247 2QT0248


RL-60° 60 46 1.81 31.8 1.25 48.5 1.91 16.5 0.65 16x19 0.63x0.75
3.5 0.14 SWI15P3.5 SWI Sealing O-ring 3SS0880 3SS0881
RL-70° 70 49 1.93 31.8 1.25 55 2.17 17 0.67 19x19 0.75x0.75
(water column) Water film 2QT0245 2QK5893
4 0.16 SWI15P4
15 Threaded collar 2QK5893 2QK5894
4.5 0.18 SWI15P4.5
5 0.20 SWI15P5
5.5 0.22 SWI15P5.5
2QT0247
6 0.24 SWI15P6
2.5 0.10 SWI20P2.5
3 0.12 SWI20P3
3.5 0.14 SWI20P3.5
2QK5893
4 0.16 SWI20P4
20
4.5 0.18 SWI20P4.5
5 0.20 SWI20P5
5.5 0.22 SWI20P5.5
6 0.24 SWI20P6

3SS0880 2QT0245

57 UT Probes UT Probes 58
Contact Probe - TRL Angle Beam Probes Applications Probe Specification
Focal Length(FS)
Frequency ax b β(°) Model
Nuclear power station Min Max
Austenitic stainless steel MHz mm in ss mm in mm in PL C
Independent transmit and receive crystals, refracting ultrasonic beam angles and DA1.5C20X34LA45FS80-IAOD980 Near surface flaw detection 0.5 20 x 34 0.79 x 1.34 45 25 0.98 60 2.36 / DA0.5C20 x 34LA45
creates certain focal length in workpiece. Plate weld inspection 0.5 20 x 34 0.79 x 1.34 60 20 0.79 35 1.38 / DA0.5C20 x 34LA60
0.5 20 x 34 0.79 x 1.34 70 20 0.79 30 1.18 / DA0.5C20 x 34LA60
High attenuation materials
1 8 x 14 0.31 x 0.55 45 10 0.39 25 0.98 DA1P8 x 14LA45 DA1C8 x 14LA45
DA2C15X25LA45FD40 1 8 x 14 0.31 x 0.55 60 10 0.39 20 0.79 DA1P8 x 14LA60 DA1C8 x 14LA60
Features Instructions 1 8 x 14 0.31 x 0.55 70 10 0.39 20 0.79 DA1P8 x 14LA70 DA1C8 x 14LA70
1 10 x 18 0.39 x 0.71 45 15 0.59 30 1.18 DA1P10 x 18LA45 DA1C10 x 18LA45
No initial pulse dead zone effects C - composite series is the default probe 1 10 x 18 0.39 x 0.71 60 15 0.59 30 1.18 DA1P10 x 18LA60 DA1C10 x 18LA60
Less scattering, higher SNR in high attenuation material type 1 10 x 18 0.39 x 0.71 70 15 0.59 25 0.98 DA1P10 x 18LA70 DA1C10 x 18LA70
Probe face can be processed into different shapes to ensure good coupling Default built-in delay lines, for external 1 15 x 25 0.59 x 0.98 45 20 0.79 55 2.17 DA1P15 x 25LA45 DA1C15 x 25LA45

with workpiece: 1 15 x 25 0.59 x 0.98 60 20 0.79 45 1.77 DA1P15 x 25LA60 DA1C15 x 25LA60
delay lines of 3~3.5mm can be customized
AID(Axial Inside Diameter), CID(Circumferential Inside Diameter), 1 15 x 25 0.59 x 0.98 70 15 0.59 40 1.57 DA1P15 x 25LA70 DA1C15 x 25LA70
Default probe is without irrigation holes,
1 20 x 34 0.79 x 1.34 45 30 1.18 80 3.15 DA1P20 x 34LA45 DA1C20 x 34LA45
AOD(Axial Outside Diameter), COD(Circumferrential Outside Diameter) which can be customized
1 20 x 34 0.79 x 1.34 60 25 0.98 75 2.95 DA1P20 x 34LA60 DA1C20 x 34LA60
Two types of performance probes can meet most of detection needs: FS means sound path, FD means focal
1 20 x 34 0.79 x 1.34 70 25 0.98 70 2.76 DA1P20 x 34LA70 DA1C20 x 34LA70
depth, conversion of FS, FD and β is:
2 7 x 10 0.28 x 0.39 45 10 0.39 25 0.98 DA2P7 x 10LA45 DA2C7 x 10LA45
“PL ” Universal Series, “C ” Composite Series Cosβ=FD/(FS+0.5D), where D is diameter 2 7 x 10 0.28 x 0.39 60 10 0.39 25 0.98 DA2P7 x 10LA60 DA2C7 x 10LA60
DA2C8X14LA45FD25 Lemo 00(C5) top mounting connectors, side 2 7 x 10 0.28 x 0.39 70 10 0.39 20 0.79 DA2P7 x 10LA70 DA2C7 x 10LA70
mounting can be customized 2 8 x 14 0.31 x 0.55 45 15 0.59 30 1.18 DA2P8 x 14LA45 DA2C8 x 14LA45
2 8 x 14 0.31 x 0.55 60 10 0.39 30 1.18 DA2P8 x 14LA60 DA2C8 x 14LA60
2 8 x 14 0.31 x 0.55 70 10 0.39 25 0.98 DA2P8 x 14LA70 DA2C8 x 14LA70
2 10 x 18 0.39 x 0.71 45 20 0.79 45 1.77 DA2P10 x 18LA45 DA2C10 x 18LA45
2 10 x 18 0.39 x 0.71 60 15 0.59 40 1.57 DA2P10 x 18LA60 DA2C10 x 18LA60
Probe Dimensions
2 10 x 18 0.39 x 0.71 70 15 0.59 30 1.18 DA2P10 x 18LA70 DA2C10 x 18LA70
Nominal Element Size A B C
2 15 x 25 0.59 x 0.98 45 25 0.98 85 3.35 DA2P15 x 25LA45 DA2C15 x 25LA45
mm in mm in mm in mm in
2 15 x 25 0.59 x 0.98 60 20 0.79 75 2.95 DA2P15 x 25LA60 DA2C15 x 25LA60
7 x 10 0.28 x 0.39 25.0 0.98 25.0 0.98 30.0 1.18
2 15 x 25 0.59 x 0.98 70 20 0.79 70 2.76 DA2P15 x 25LA70 DA2C15 x 25LA70
8 x 14 0.31 x 0.55 25.0 0.98 25.0 0.98 30.0 1.18
2 20 x 34 0.79 x 1.34 45 40 1.57 120 4.72 DA2P20 x 34LA45 DA2C20 x 34LA45
10 x 18 0.39 x 0.71 30.0 1.18 30.0 1.18 30.0 1.18
2 20 x 34 0.79 x 1.34 60 30 1.18 120 4.72 DA2P20 x 34LA60 DA2C20 x 34LA60
15 x 25 0.59 x 0.98 40.0 1.57 40.0 1.57 35.0 1.38
2 20 x 34 0.79 x 1.34 70 30 1.18 105 4.13 DA2P20 x 34LA70 DA2C20 x 34LA70
20 x 34 0.79 x 1.34 50.0 1.97 50.0 1.97 39.5 1.56
4 7 x 10 0.28 x 0.39 45 10 0.39 35 1.38 DA4P7 x 10LA45 DA4C7 x 10LA45
4 7 x 10 0.28 x 0.39 60 10 0.39 35 1.38 DA4P7 x 10LA60 DA4C7 x 10LA60
4 7 x 10 0.28 x 0.39 70 10 0.39 30 1.18 DA4P7 x 10LA70 DA4C7 x 10LA70
4 8 x 14 0.31 x 0.55 45 20 0.79 60 2.36 DA4P8 x 14LA45 DA4C8 x 14LA45
Probe Dimensions(CDA Model) 4 8 x 14 0.31 x 0.55 60 15 0.59 55 2.17 DA4P8 x 14LA60 DA4C8 x 14LA60
Nominal Element Size A B C Clamping Holes
4 8 x 14 0.31 x 0.55 70 10 0.39 50 1.97 DA4P8 x 14LA70 DA4C8 x 14LA70
mm in mm in mm in mm in mm
4 10 x 18 0.39 x 0.71 45 25 0.98 85 3.35 DA4P10 x 18LA45 DA4C10 x 18LA45
7×10 0.28×0.39 20.0 0.79 20.0 0.79 20.0 0.79
4 10 x 18 0.39 x 0.71 60 20 0.79 70 2.76 DA4P10 x 18LA60 DA4C10 x 18LA60
8×14 0.31×0.55 25.0 0.98 25.0 0.98 25.0 0.98
4 10 x 18 0.39 x 0.71 70 15 0.59 60 2.36 DA4P10 x 18LA70 DA4C10 x 18LA70
10×18 0.39×0.71 30.0 1.18 30.0 1.18 25.0 0.98 M4×0.7
4 15 x 25 0.59 x 0.98 45 30 1.18 100 3.94 DA4P15 x 25LA45 /
15×25 0.59×0.98 40.0 1.57 40.0 1.57 35.0 1.38
4 15 x 25 0.59 x 0.98 60 25 0.98 90 3.54 DA4P15 x 25LA60 /
20×34 0.79×1.34 50.0 1.97 50.0 1.97 35.0 1.38
4 15 x 25 0.59 x 0.98 70 20 0.79 80 3.15 DA4P15 x 25LA70 /

59 UT Probes UT Probes 60
Contact Probe - Delay Line Probes and Wedges Probe Specification Probe Specification Probe Specification
mm in mm in mm in
With replaceable delay line at the front of probe, and sound wave vertical incidence into workpiece. 13 0.50 3 0.125 5 0.20
6 0.25

Features Applications
Replaceable delay lines Direct flaw detection
High bandwidth and narrow pulse with delay line, ensure excellent Precise thickness measurements
near surface resolution Near surface flaw detection
Higher frequency increases resolution of detection Surface detection of curved workpiece
Ultra thin workpiece detection
<Note>: Thickness of delay line decides the maximum thickness of workpiece, Doppler
Provide 3 different thicknesses of delay lines to meet the most detection cases; Length and
materials of delay line can be customized. Delay Line (P)

Replaceable delay lines
Ultra small contact area of probe front, suitable for high bending
DL-20P3-H surface detection, such as turbine blades
Delay Line (DL) 3 types handle bars: horizontal, 45° and 90°
Replaceable horizontal handle bar
DL-10P6-H DL-15P6-H
Delay line can be purchased separately Delay line can be purchased separately, model: 1GW2912
Default length of delay lines: Microdot (L5) tail-end mounting connector
Φ3mm(0.125in) crystal probe with 5.5mm(0.22in) length of delay line
Φ5/6/13mm(0.2/0.25/0.5in) crystal probe with 12.7mm(0.5in) length of delay line
Microdot (L5) side mounting connector

Probe Specification
Probe Specification Frequency Nominal Element Size Model
Frequency Nominal Element Size
DL-10P3-H MHz mm in PH
Model
MHz mm in PH P-10P3-H(0°)
6 0.25 DL-2.25P6-H 10 3 0.125 P-10P3-H(45°)
2.25
13 0.50 DL-2.25P13-H P-10P3-H(90°)
3.5 6 0.25 DL-3.5P6-H P-15P3-H(0°)
5 0.20 DL-5P5-H Delay Line Specification 15 3 0.125 P-15P3-H(45°)
5 6 0.25 DL-5P6-H Length Nominal Element Size P-15P3-H(90°)
Model
13 0.50 DL-5P13-H mm in mm in
3 0.125 DL-10P3-H DLΦ3-5.5 5.5 0.22 3 0.125
5 0.20 DL-10P5-H 5 0.20
10 DLΦ6-9.5 9.5 0.37
6 0.25 DL-10P6-H 6 0.25 1GW2912
13 0.50 DL-10P13-H 5 0.20
DLΦ6-12.7 12.7 0.50
5 0.20 DL-15P5-H 6 0.25
15
6 0.25 DL-15P6-H DLΦ13-9.5 9.5 0.37 13 0.50
DLφ6-12.7
20 3 0.125 DL-20P3-H DLΦ13-12.7 12.7 0.50 13 0.50

61 UT Probes UT Probes 62
TOFD Probes and Wedges Nominal Element Size A
Probe Dimensions
B C
Connector Direction
mm in mm in mm in mm in
TOFD Probe and Delay Line can generate refracting longitudinal in steel, and use time of flight diffraction technique to determine the cracks. 3 0.125
11 0.43 16.5 0.65 6 0.24
6 0.25 Microdot/
Top Mounting
10 0.375 16 0.63 18 0.71 6.5 0.26
12 0.50 18 0.71 20 0.79 6.5 0.26
Features
High damping and wide bandwidth performance
High efficiency for welding inspection
TF1 Delay Line Dimensions TF1 Delay Line Dimensions
Quick change structure of probe and delay line
β(°) A B C Threads β(°) A B C Threads
IHC for irrigation, holes, carbides of delay line Model Model
Steel mm in mm in mm in in Steel mm in mm in mm in in
TF1-L45-IHC 45 TF1-L45-IHS 45
TF1-L60-IHC 60 32 1.26 21 0.83 13 0.51 3/8-32 TF1-L60-IHS 60 32 1.26 21 0.83 13 0.51 3/8-32
TF1-L70-IHC 70 TF1-L70-IHS 70

Applications
Plate butt weld inspections
Directional irregular defects TF2 Delay Line Dimensions TF2 Delay Line Dimensions
Near surface defects detection β(°) A B C Threads β(°) A B C Threads
Model Model
Steel mm in mm in mm in in Steel mm in mm in mm in in
TF2-L45-IHC 45 TF2-L45-IHS 45
TF2-L60-IHC 60 32 1.26 28 1.1 18 0.71 11/16-24 TF2-L60-IHS 60 32 1.26 28 1.1 18 0.71 11/16-24
TF2-L70-IHC 70 TF2-L70-IHS 70

Probe Specification
Frequency Nominal Element Size Threads
Models Delay Line Model
MHz mm in in TF2.25C10L
6 0.25 TF2.25C6L 3/8-32 TF1
2.25 10 0.375 TF2.25C10L 11/16-24 TF2
12 0.5 TF2.25C12L 11/16-24 TF2
6 0.25 TF3.5C6L 3/8-32 TF1 TF1-L45-IHC
3.5
10 0.375 TF3.5C10L 11/16-24 TF2
3 0.125 TF5C3L 3/8-32 TF1
6 0.25 TF5C6L 3/8-32 TF1
5
10 0.375 TF5C10L 11/16-24 TF2
12 0.5 TF5C12L 11/16-24 TF2
3 0.125 TF7.5C3L 3/8-32 TF1
7.5
6 0.25 TF7.5C6L 3/8-32 TF1
3 0.125 TF10C3L 3/8-32 TF1 TF5C6L
10
6 0.25 TF10C6L 3/8-32 TF1
15 3 0.125 TF15C3L 3/8-32 TF1
TF1-L60-IHS
TF1-L45-IHC
AOD304

63 UT Probes UT Probes 64
Immersion Probes European Standard - I1
Top mounting with 1.8 meter or 2.5 meter cable length, cable end with
Probe is design for total or partial immersion into water or other liquids to create ultrasonic beams. I1-5P10
Lemo 01 (C9) connector

Probe Specification
Frequency Nominal Element Size Model Focal Range
Features Applications Min Max
MHz mm in PL PH C
mm in mm in
Strong pressure and corrosion resistance Unfocused probes (planar) are used for general 1 20 0.79 I1-1P20 I1-1P20-H I1-1C20 32 1.26 50 1.97
Excellent acoustic impedance in water or other liquids, 1/4 applications and penetrating thicker materials 10 0.39 I1-2P10 I1-2P10-H I1-2C10 18 0.71 25 0.98
wavelength of matching layer can ensure maximum power outputs Point focused probe (spherical surface) is generally 2
20 0.79 I1-2P20 I1-2P20-H I1-2C20 30 1.18 85 3.35
No coupling issues between probe and liquid used to improve the sensitivity and signal-to-noise 10 0.39 I1-4P10 I1-4P10-H I1-4C10 22 0.87 45 1.77
4
Acoustic beam can perform spherical focusing (F) or line focusing ratio of small flaw defection 20 0.79 I1-4P20 I1-4P20-H / 45 1.77 180 7.09
(CF), to increase ability of defect identifications Line focused probe (cylindrical surface) is generally 5 0.20 I1-5P5 I1-5P5-H I1-5C5 11 0.43 20 0.79
5
Three types of performance probes can meet most of detection needs used for the detection of pipes and bars 10 0.39 I1-5P10 I1-5P10-H I1-5C10 20 0.79 55 2.17
Online thickness measurement; Automatic scanning; 5 0.20 I1-10P5 I1-10P5-H I1-10C5 12 0.47 38 1.50
10
“PL” Universal Series, “PH” Short Pulsing Series, Material analysis; Imaging system 10 0.39 I1-10P10 I1-10P10-H / 15 0.59 100 3.94

“C” Composite Series 15 5 0.20 / I1-15P5-H / 12 0.47 35 1.38

Probe Dimensions Probe Dimensions


Nominal Element Size Nominal Element Size A B C
Instruction: mm in mm in mm in mm in m ft
1. Most water immersion probes working between - 10 ~ 5 0.20 10 0.39 13 0.51 62 2.44 2.5 8.2
55 ° C (14 ~ 131 ° f). If the temperature exceeds the limit,
20 0.79 24 0.94 62 2.44 2.5 8.2
peeling will occur between components, resulting in
permanent damage to the probe. Limit working
temperature (customized) can reach -55 ~ 120 ° C (- 67 ~
(a) (b) (a) (b)
248 ° f).
2. Transducers should not be submerged for periods
exceeding 8 hours. Allow 16 hours of dry time to ensure
the life of the unit.
3. The focusing distance of the unfocused probe is about
equal to its near-field length. Since the last maximum
amplitude of the probe occurs at a distance equivalent to
North America Standard - I2
the near-field length, all probes cannot focus when it is
greater than the near-field length. Top mounting UHF waterproof connector
4. At a given frequency and element size, the focal length
of the probe is limited. The actual maximum amplitude of
unfocused probe is about 0.6 times of the near-field Probe Dimensions
length, and that of point focused probe is about 0.8 times Nominal Element Size A B C
of the near-field length, for line focused probe max
mm in mm in mm in m in
amplitude may not correspond to the nominal focusing.
When the focus probe exceeds the above maximum but 19 0.75 25 1.00 27 1.06 32 1.25
less than the near-field length, the increased sensitivity at 25 1.00 32 1.25 34 1.32 32 1.25
the focus is not obvious. 29 1.125 35 1.38 37 1.44 32 1.25
5. For the problem of the long focus length transducer 38 1.50 44 1.75 46 1.81 38 1.50
has a large offset in the center frequency near the focus
point, please refer to the description on the probe test
report.

65 UT Probes UT Probes 66
Probe Specification
Frequency Nominal Element Size Model Focal Range North America Standard - I3
Min Max
MHz mm in PL PH C 9.7mm (0.375in) outer diameter, suitable for limited detection environment
mm in mm in
19 0.75 / I2-0.5P19-H / 25 0.98 25 0.98 Top mounting Microdot (L5) non-waterproof connector
25 1.00 I2-0.5P25 I2-0.5P25-H / 35 1.38 42 1.65
0.5
29 1.125 I2-0.5P29 I2-0.5P29-H / 40 1.57 52 2.05
38 1.50 I2-0.5P38 I2-0.5P38-H / 60 2.36 95 3.74 Probe Specification
Nominal Element Size
13 0.50 I2-1P13 I2-1P13-H / 16 0.63 20 0.79 Nominal Focal Range
mm in Frequency Model
19 0.75 I2-1P19 I2-1P19-H I2-1C19 30 1.18 45 1.77 Element Size Min Max
10 0.38 1 25 1.00 I2-1P25 I2-1P25-H / 48 1.89 75 2.95 MHz mm in PL PH mm in mm in
13 0.50 29 1.125 I2-1P29 I2-1P29-H / 55 2.17 90 3.54 2.25 6 0.25 I3-2.25P6 I3-2.25P6-H 10 0.39 12 0.47
38 1.50 I2-1P38 I2-1P38-H / 70 2.76 190 7.48 3.5 6 0.25 I3-3.5P6 I3-3.5P6-H 11 0.43 17 0.67
6 0.25 I2-2.25P6 I2-2.25P6-H I2-2.25C6 10 0.39 12 0.47
5 6 0.25 I3-5P6 I3-5P6-H 12 0.47 25 0.98
10 0.375 I2-2.25P10 I2-2.25P10-H I2-2.25C10 20 0.79 27 1.06
10 6 0.25 / I3-10P6-H 13 0.51 45 1.77
13 0.50 I2-2.25P13 I2-2.25P13-H I2-2.25C13 25 0.98 45 1.77
3 0.125 / I3-15P3-H 7 0.28 15 0.59
2.25 19 0.75 I2-2.25P19 I2-2.25P19-H / 32 1.26 95 3.74 15
6 0.25 / I3-15P6-H 13 0.51 40 1.57
25 1.00 I2-2.25P25 I2-2.25P25-H / 55 2.17 160 6.30
20 3 0.125 / I3-20P3-H 8 0.31 22 0.87 I3-10P6-H
29 1.125 I2-2.25P29 I2-2.25P29-H / 62 2.44 200 7.87
25 3 0.125 / I3-25P3-H 10 0.39 23 0.91
38 1.50 / I2-2.25P38-H / 70 2.76 370 14.57
6 0.25 I2-3.5P6 I2-3.5P6-H I2-3.5C6 12 0.47 17 0.67
10 0.375 I2-3.5P10 I2-3.5P10-H I2-3.5C10 20 0.79 38 1.50
13 0.50 I2-3.5P13 I2-3.5P13-H / 22 0.87 65 2.56
3.5
19 0.75 I2-3.5P19 I2-3.5P19-H / 40 1.57 150 5.91
Nominal Element Size 25 1.00 I2-3.5P25 I2-3.5P25-H / 50 1.97 270 10.63
mm in 29 1.125 / I2-3.5P29-H / 80 3.15 360 14.17
3 0.13 6 0.25 I2-5P6 I2-5P6-H I2-5C6 12 0.47 25 0.98
6 0.25 10 0.375 I2-5P10 I2-5P10-H I2-5C10 20 0.79 55 2.17
13 0.50 I2-5P13 I2-5P13-H I2-5C13 22 0.87 100 3.94
5
19 0.75 I2-5P19 I2-5P19-H / 40 1.57 210 8.27 North America Standard - I4
25 1.00 I2-5P25 I2-5P25-H / 60 2.36 350 13.78
29 1.125 / I2-5P29-H / 80 3.15 420 16.54 9.4mm (0.37in) outer diameter, 51mm (2in) length, suitable for hard to reach detection areas
6 0.25 I2-7.5P6 I2-7.5P6-H I2-7.5C6 15 0.59 30 1.18 Top mounting UHF waterproof connector
10 0.375 I2-7.5P10 I2-7.5P10-H / 18 0.71 40 1.57
13 0.50 I2-7.5P13 I2-7.5P13-H / 25 0.98 80 3.15 Probe Specification
I2-20P3-H 7.5
19 0.75 / I2-7.5P19-H / 27 1.06 220 8.66
Nominal Focal Range
25 1.00 / I2-7.5P25-H / 80 3.15 530 20.87 Frequency Element Size Model
I2-5P19-H Min Max
29 1.125 / I2-7.5P29-H / 100 3.94 600 23.62
MHz mm in PL PH mm in mm in
6 0.25 I2-10P6 I2-10P6-H / 13 0.51 40 1.57
2.25 6 0.25 I4-2.25P6 I4-2.25P6-H 10 0.39 12 0.47
10 0.375 I2-10P10 I2-10P10-H / 15 0.59 100 3.94
0.50 / I2-10P13-H / 25 0.98 120 4.72 3.5 6 0.25 I4-3.5P6 I4-3.5P6-H 11 0.43 17 0.67
13
10 5 6 0.25 I4-5P6 I4-5P6-H 12 0.47 25 0.98
19 0.75 / I2-10P19-H / 30 1.18 370 14.57
25 1.00 / I2-10P25-H / 60 2.36 470 18.50 10 6 0.25 / I4-10P6-H 13 0.51 45 1.77
29 1.125 / I2-10P29-H / 90 3.54 580 22.83 3 0.125 / I4-15P3-H 7 0.28 15 0.59
15
6 0.25 / I2-15P6-H / 13 0.51 40 1.57 6 0.25 / I4-15P6-H 13 0.51 40 1.57
15 10 0.375 / I2-15P10-H / 20 0.79 120 4.72 20 3 0.125 / I4-20P3-H 8 0.31 22 0.87
13 0.50 / I2-15P13-H / 23 0.91 220 8.66 25 3 0.125 / I4-25P3-H 10 0.39 23 0.91 I4-10P6-H
3 0.125 / I2-20P3-H / 7 0.28 20 0.79
20
I2-10P13F60-H I2-15P6-H 6 0.25 / I2-20P6-H / 14 0.55 60 2.36
3 0.125 / I2-25P3-H / 10 0.39 23 0.91
25
6 0.250 / I2-25P6-H / 14 0.55 100 3.94

67 UT Probes UT Probes 68
North America Standard - I5 High Frequency Probes
Cuboid profile, sound wave direction and connector into a 90 degree, for specific application environment High frequency probe refers to a single element transducer with a frequency higher than 20MHz, which includes HF contact probe, HF
Top mounting UHF waterproof connector immersion probe and HF immersion self – focusing probe.

Features Applications
Probe Specification
Frequency Nominal Element Size Model Focal Range Both contact probes and immersion probes have integrated delay lines, Minor cracks on the surface
Min Max and self - focusing immersion probes do not have delay lines or lens High resolution detection effect is required, such as the
MHz mm in PL PH C
mm in mm in The frequency range is 20 ~ 50MHz ability to find small cracks or pores
1 13 0.50 I5-1P13 I5-1P13-H I5-1C13 16 0.63 20 0.79 With broadband and narrow pulse performance, the probe has With the ideal surface condition, temperature and excitation
6 0.25 I5-2.25P6 I5-2.25P6-H I5-2.25C6 10 0.39 12 0.47 excellent near surface resolution and vertical and horizontal resolution setting, the thinnest thickness that 50MHz probe can reach
2.25 10 0.375 I5-2.25P10 I5-2.25P10-H I5-2.25C10 20 0.79 27 1.06 A very small focal spot diameter in the near field or focus point in steel is 0.05 mm (0.0019 in) in thickness measurement
13 0.50 I5-2.25P13 I5-2.25P13-H I5-2.25C13 25 0.98 45 1.77 Side mounted microdot connector for contact probe by default, and top mode
6 0.25 I5-3.5P16 I5-3.5P6-H I5-3.5C6 20 0.79 38 1.50 Scanning acoustic microscope
mounted UHF interface for immersion probe and immersion self-
3.5 10 0.375 I5-3.5P10 I5-3.5P10-H I5-3.5C10 20 0.79 38 1.50
focusing probe by default
13 0.50 I5-3.5P13 I5-3.5P13-H I5-3.5C13 22 0.87 65 2.56
6 0.25 I5-5P6 I5-5P6-H I5-5C6 12 0.47 25 0.98
5 10 0.375 I5-5P10 I5-5P10-H I5-5C10 20 0.79 55 2.17
13 0.50 I5-5P13 I5-5P13-H I5-5C13 22 0.87 100 3.94 Direct Contact Type Signal & Spectrum
6 0.25 / I5-10P6-H / 13 0.51 45 1.77 Frequency Nominal Element Size Delay Time
Model
10 10 0.375 I5-10P10 I5-10P10-H / 15 0.59 100 3.94
I5-3.5P10 MHz mm in µs

13 0.50 I5-10P13 I5-10P13-H / 25 0.98 120 4.72 20 6 0.25 4.25 HFN20V6-4


30 6 0.25 4.25 HFN30V6-4
50 6 0.25 4.25 HFN50V6-4

Liquid Immersion Type


Frequency Nominal Element Size Delay Time
Model
Probe Dimensions MHz mm in µs
Nominal Element Size A B C 20 6 0.25 4.25 HFI20V6-4
mm in mm in mm in m in 30 6 0.25 4.25 HFI30V6-4
6 0.25 50 6 0.25 4.25 HFI50V6-4
10 0.375 19 0.75 24 0.94 19 0.75
13 0.50

Liquid Immersion Self - Focusing Type(“**” Custom Length)


Frequency Nominal Element Size Self-Focal Length
Model
MHz mm in mm/in
3 0.125 HFI20V3BCF**
20 6 0.25 HFI20V6BCF**
3 0.125 HFI30V3BCF**
30 Custom
6 0.25 HFI30V6BCF**
3 0.125 HFI50V3BCF **
50
6 0.25 HFI50V6BCF**

69 UT Probes UT Probes 70
High Temperature Delay Line Probes and Wedges HT2-Φ10-70° HT2-Φ6-60°

Single crystal probe with a replaceable delay line, applied for high temperature detection environment. TEMP(°C/°F)/Max Operation Time
Type
HT1 HT2
ZH (170 ℃/ 338 °F)/10 (500 ℃/ 932 °F)/10
AH (130 ℃/ 266 °F)/10 (270 ℃/ 518 °F)/10

Applications
HT2-Φ10-45°
Intermittent contact detection with high temperature workpiece (castings, forgings etc.)
Direct flaw detection
Detection of curved surface of workpiece HT2-Φ13-25 HT1-Φ19-13

Features 6mm (0.25in) AH Type Delay Line Dimensions


β(°) A B C Threads Nominal Element Size
Supply 0° (ZH type) longitudinal incidence and 45°/ 60°/70° (AH type) shear wave incidence Model
Steel mm in mm in mm in in mm in
delay lines 45 19.1 0.75 11.4 0.45 9.4 0.37 3/8-32
HT1-Φ6-45°
Supply 13 / 25 / 38mm three ZH types standard height delay lines, and 45°/60°/70° three 21.3 0.84 11.4 0.45 11.2 0.44 3/8-32
HT1-Φ6-60° 60
shear wave AH types delay lines
HT1-Φ6-70° 70 25.4 1.00 11.4 0.45 12.7 0.50 3/8-32
Two types of delay lines: ZH Type AH Type 6 0.25
HT2-Φ6-45° 45 19.1 0.75 11.4 0.45 9.4 0.37 3/8-32
HT1: maximum 20seconds on workpiece at 200 °C(392 °f)
HT2-Φ6-60° 60 21.3 0.84 11.4 0.45 11.2 0.44 3/8-32
HT2: maximum 10seconds on workpiece at 300 °C(572 °f)
HT2-Φ6-70° 70 25.4 1.00 11.4 0.45 12.7 0.50 3/8-32
Quick change structure of delay line and probe Probe Dimensions
Standard lengths of ZH type delay line matching with probes: Nominal Element Size A B
Φ10 mm (0.375 in) crystal probe with 13 mm (0.5 in) delay line mm in mm in mm in ZH Type Delay Line Dimensions 10mm (0.375in) AH Type Delay Line Dimensions
Φ13/19 mm (0.5/0.7 in) crystal probe with 25 mm (1.0 in) delay line 6 0.25 11 0.42 14 0.56
Model
A B Threads Nominal Element Size
Model
β(°) A B C Threads Nominal Element Size
Probe face can be processed into different shapes to ensure good coupling with workpiece 10 0.375 14 0.55 15 0.58 mm in mm in in mm in Steel mm in mm in mm in in mm in
Top mounting Microdot (L5) connector 13 0.50 18 0.70 17 0.65 HT1-Φ10-13 15 0.60 13 0.50 1/2-28 HT1-Φ10-45° 45 22.6 0.89 14 0.55 11.9 0.47 1/2-28
19 0.75 25 0.98 20 1.00 HT1-Φ10-25 15 0.60 25 1.00 1/2-28 10 0.375
HT1-Φ10-60° 60 26.4 1.04 14 0.55 14 0.55 1/2-28
Attention: HT1-Φ10-38 15 0.60 38 1.50 1/2-28
HT1-Φ10-70° 70 30.2 1.19 14 0.55 14.7 0.58 1/2-28
1. When reach maximum contact time, probe is required to cool down to room temperature to working again. HT1-Φ13-13 18 0.70 13 0.50 5/8-24 10 0.375
HT2-Φ10-45° 45 22.6 0.89 14 0.55 11.9 0.47 1/2-28
2. The contact time is related to the contact temperature. For the specific relationship between them, please consult HT1-Φ13-25 18 0.70 25 1.00 5/8-24 13 0.5
with Doppler transducer expert. HT2-Φ10-60° 60 26.4 1.04 14 0.55 14 0.55 1/2-28
HT1-Φ13-38 18 0.70 38 1.50 5/8-24
HT2-Φ10-70° 70 30.2 1.19 14 0.55 14.7 0.58 1/2-28
HT1-Φ19-13 28 1.10 13 0.50 1-20
HT-2.25P13 Probe Specification HT1-Φ19-25 28 1.10 25 1.00 1-20 19 0.75
Frequency Nominal Element Size Model Threads HT1-Φ19-38 28 1.10 38 1.50 1-20 13mm (0.5in) AH Type Delay Line Dimensions
MHz mm in PL in HT2-Φ10-13 15 0.60 13 0.50 1/2-28
β(°) A B C Threads Nominal Element Size
2.25 6 0.25 HT-2.25P6 3/8-32 HT2-Φ10-25 15 0.60 25 1.00 1/2-28 10 0.375 Model
Steel mm in mm in mm in in mm in
2.25 10 0.375 HT-2.25P10 1/2-28 HT2-Φ10-38 15 0.60 38 1.50 1/2-28
HT1-Φ13-45° 45 26.7 1.05 17.8 0.70 14 0.55 5/8-24
2.25 13 0.50 HT-2.25P13 5/8-24 HT2-Φ13-13 18 0.70 13 0.50 5/8-24
2.25 19 0.75 HT-2.25P19 HT1-Φ13-60° 60 31.5 1.24 17.8 0.70 16.3 0.64 5/8-24
1-20 HT2-Φ13-25 18 0.70 25 1.00 5/8-24 13 0.5
5 6 0.25 HT-5P6 3/8-32 HT1-Φ13-70° 70 35.8 1.41 17.8 0.70 17.3 0.68 5/8-24
HT2-Φ13-38 18 0.70 38 1.50 5/8-24 13 0.5
5 10 0.375 HT-5P10 1/2-28 HT2-Φ19-13 28 1.10 13 0.50 1-20 HT2-Φ13-45° 45 26.7 1.05 17.8 0.70 14 0.55 5/8-24
5 13 0.50 HT-5P13 5/8-24 HT2-Φ19-25 28 1.10 25 1.00 1-20 19 0.75 HT2-Φ13-60° 60 31.5 1.24 17.8 0.70 16.3 0.64 5/8-24
HT-5P10 5 19 0.75 HT-5P19 1-20 HT2-Φ19-38 28 1.10 38 1.50 1-20 HT2-Φ13-70° 70 35.8 1.41 17.8 0.70 17.3 0.68 5/8-24
HT-5P6

UT Probes Conventional UT Probes


71 63 Conventional UT Probes
UT Probes64 72
Range Operation TEMP
Thickness Measurement Probes Probe Frequency Bottom Contact OD Cable Accur-*
Model Application Line-out Connector
Type MHz mm in mm in °F ℃ (option) (option)
DL-10P6-H 10 7.9 0.31 0.5-14.5 0.02-0.57 -4 +140 -20 +60 Side Microdot
DL-15P5-H Delayline/Normal 15 7.9 0.31 0.25-14.5 0.01-0.57 -4 +140 -20 +60 Side Microdot
Doppler provides an existing solution for most corrosion application sites, providing a complete set of twin- crystal and single-crystal DL-20P3-H 20 4.8 0.19 0.15-6 0.006-0.24 -4 +140 -20 +60 Side Microdot
thickness measuring probes for thickness measurement of workpiece, work with Accur 1/3/5 different thickness measuring instruments, to P-15P3-H(0°) 15 2.0 0.08 0.5-10 0.02-0.39 -4 +140 -20 +60 Top Microdot
ensure the accuracy of thickness measurement to the greatest extent; besides the measurement of corrosion wall thickness, it can also be P-15P3-H(45°) Pen type/Normal 15 2.0 0.08 0.5-10 0.02-0.39 -4 +140 -20 +60 45° Side Microdot
Single
Crystal P-15P3-H(90°) 15 2.0 0.08 0.5-10 0.02-0.39 -4 +140 -20 +60 Side Microdot 1GC0423 3
used for small diameter pipelines, etc. Measurement and application of tubing, boiler tube wall, penetrating coating, spot weld integrity, Side
MTN506 5 9.0 0.35 3-50 0.12-1.97 -4 +140 -20 +60 Microdot
probes with different frequencies, contact sizes and special high temperature applications are available for selection. MTN510 5 14.0 0.55 3-75 0.12-2.95 -4 +140 -20 +60 Side Microdot
MTN513 Standard/Normal 5 17.0 0.67 3-250 0.12-9.84 -4 +140 -20 +60 Side Microdot
MTN106 10 9.0 0.35 3-25 0.12-0.98 -4 +140 -20 +60 Side Microdot
MTN101 10 14.0 0.55 3-50 0.12-1.97 -4 +140 -20 +60 Side Microdot
MT121
MT506 MT105 * Contact for 10 seconds and cool to ambient temperature for reuse.Technical specifications are subject to change without notice.
MT211H MT509
1GC0520 MT509H MT105H MT211

DL-10P6-H
MTN101 MTN106 DL-20P3-H
1GC0478 DL-15P5-H
MTN513 MTN510

P-15P3-H(90°)
MTN506
Probes for Custom and Specific Applications
P-15P3-H(0°)
1GC0516
From thebeginningofDoppler, ithasalwaysbeenouradvantagetoprovidecustomerswithcustomandspecialprobesdesign,and leadingthe
MT5096 P-15P3-H(45°) MT211L probetechniquefrontiers. Tounderstand customers’demands and application requests, our experienced application engineers, probe design
MT102L
MT105L experts work together with our customers, using the best way to provide perfect application solutions and product designs, to meet & satisfy
the demands of challenging ultrasonic market.

Probe Frequency Bottom Contact OD Range Operation TEMP Cable Accur-*


Model Application Line-out Connector
Type MHz mm in mm in °F ℃ (option) (option)
Standard/Normal/ 1.5-225 0.06-8
MT509 Through Coating 5 11.5 0.45 (Through Coating 3~100) (Through Coating (0.19~3.93) -4 +140 -20 +60 Side Lemo-00 1GC0422 1

1GC0515
MT5096 Standard/Normal 5 11.5 0.45 1.5-50 0.4-2.0 -4 +140 -20 +60 Top Microdot 1GC0516 1
1GC0520
MT211 Standard/Normal 2 16.5 0.65 2-225 0.079-8 -4 +140 -20 +60 Side Lemo-00 1GC0422 1/5
MT121 Standard/Normal 1 28.5 1.12 8-80 0.31-3.15 -4 +140 -20 +60 Side Lemo-00 1GC0422 1/5
MT105H* Standard/High Temp 10 7.5 0.30 1.2-30 0.047-1.18 +32 +932 0 +500 Top Lemo-00 1GC0422 1/5
1GC0478
Twin MT509H* Standard/High Temp 5 11.5 0.45 2-200 0.079-7.87 +32 +932 0 +500 Top Microdot 1GC0514 1
Crystal
1GC0520
Standard/High Temp 0 +500 Top
Low frequency nomal probe Hollow focusing probe LW + SW dual waveforms probe LW angle probe
MT211H* 2 16.5 0.65 3-200 0.12-7.87 +32 +932 Lemo-00 1GC0422 1/5
The frequency of these probes is usually Polymer thin film element makes annular The probe has two channels, which excite The angles of LW angle probe can be 45 °
Fingertips/Normal/ 1.2-225 0.05-8.6
MT506 Through Coating 5 7.5 0.30 (Through Coating 5~20) (Through Coating 0.2~0.79) -4 +140 -20 +60 Side Microdot 1GC0424 1 between 0.05 ~ 0.25MHz. The ultra-low self focusing a reality. In the application of SW and LW respectively, it is used for the / 60 °/ 70 °. Compared with the traditional
frequency ensures good penetration and imaging system, the probe is used to measurement of material parameters, designed probe, this probe has almost no
Fingertips/Normal/ 1.2-225 0.05-8.6
MT506L 5 9.5 0.37 (Through Coating 5~20) (Through Coating 0.2~0.79) -4 +140 -20 +60 Side Lemo-00 WithCable 1.2m 1 signal-to-noise ratio in some attenuation receive laser beam. such as elastic modulus, shear modulus, interference of initial blind area in
Through Coating
materials such as stone, wood, rubber Poisson's ratio and sound velocity. detection.
MT102L Fingertips/Normal 10 3.0 0.12 1-8 0.04-0.31 -4 +140 -20 +60 Side Lemo-00 WithCable 1.5m 1/5 and concrete.
MT105 Fingertips/Normal 10 7.5 0.30 0.8-50 0.03-1.97 -4 +140 -20 +60 Side Microdot 1GC0424 1/5
MT105L Fingertips/Normal 10 7.2 0.28 0.8-50 0.03-1.97 -4 +140 -20 +60 Side Lemo-00 WithCable 1.5m 1/5
MT211L Fingertips/Normal 2 15.5 0.61 2-225 0.079-8.0 -4 +140 -20 +60 Side Lemo-00 WithCable 1.5m 1/5

73 UT Probes UT Probes 74
Dual creeping wave focusing probe Plate wave probe Low temperature thickness probe Water wedge dual element probe Hollow shaft detection probe High frequency water filling probe Special dual element straight probe Wheeled industrial probe
Used for the detection of pillar ceramic Used to generate plate waves in thin plates. The probe can be used for measuring the The probe is used to detect PE pipes. The This series of probes are used to detect rail The working mode of the probe is liquid This probe is dedicated to automatic This probe with rolling tires can be used
insulator materials in power industry. thickness of ice layer, and the limit traditional solid wedge is replaced by and the hollow shaft connecting rod of immersion type. Liquid is injected through inspection systems for steel plates. for workpiece inspection such as flat
working temperature can reach - 55 ° C (- liquid. Sound wave propagates through wheels in the railway industry. the side water pipe, realizing good coupling
plates, special-shaped workpiece, etc.
67 ° F). the liquid and focuses in the PE pipe for between the transparent conical tube and
detection. workpiece.

Variable angle probe 1T3R steel plate inspection probe High frequency immersion probe Special immersion probe T1R2 critical angle probe I2 immersion probe mirror I2 immersion probe extension rod
Used for measuring the angle and For automatic detection of steel plate in With a frequency of 20MHz and short 15MHz, short pulsing performance, and This probe is designed for stress detection. This mirror is used to guide the sound beam This extension rod can be used for
performance before finalizing products, iron and steel industry. pulsing performance, it is used for some housing sizes are only φ 5 × 5mm. by 90° refraction. UHF-interfaced immersion probe
and the angle is adjustable from 0 ~ 90 °. special areas that are difficult to deeply Cooperate with specific probe holder, it
extensions.
penetrate. can detect the thickness of metal pipe (≤
0.5mm) during high-speed rotation.

Special probe with handle High temperature resistant dual probe Aluminum measurement angle probe Special probe with guide rail slot
Used in limited detection space, such as The probe is used for flaw detection of This probe is used for welding inspection of The front end of the probe is equipped
turbine blade, the front part of the probe high-temperature workpiece and can aluminum materials. with guide rail slot, can be used for axial
can bend 180 °, which improves the withstand 300 °C (572 °F). and circumferential flaw detection of System matching probe
contact with the workpiece in a tight pipes or bars, ensuring the vertical
space. incidence of sound beam, and no need The high-speed rotating probes are applied in the automatic detection system for
curvatures at the bottom of the probe. steel pipe flaw detection and thickness measurement.

75 UT Probes Conventional UT Probes


UT Probes68 76
Cables Lemo-1(Waterproof)
Adapters
The probe cable is composed of a coaxial cable The adapter can achieve fast switching between different instruments, probes, and connecting wires.
UHF(Waterproof)
(wire + insulating layer + shielding network) and
two connectors respectively connecting the probe
and the instrument, which is used for electrical Lemo-1(C9)
signal transmission between instrument and probe. Model Interface Type
Commonly used connectors include BNC (Q9), Lemo-1 Coupling
3BQ0021 BNC Male— BNC Male
Microdot (L5), Lemo-00 (C5), Lemo-1 (C9), etc.
Lemo-00(C5) BNC Male — BNC Female
Coaxial cable include RG174, RG178, RG 316, RG58, 3BQ0022
(right angle)
etc. Unless specified, the impedance value of all
3BQ0023 BNC Male —SMA Female
cables is 50 ohms. BNC(Q9)
3BQ0024 BNC Male —Microdot Female
3BQ0025 BNC Male —Lemo00 Female
BNC(Q6) 3BQ0021 3BQ0022 3BQ0023
3BQ0026 BNC Male —UHF Female
3BQ0027 BNC Female —UHF Male
3BQ0028 BNC Female —BNC Female
Microdot(L5)
3BQ0030 BNC Female —Lemo00 Male
"A" and "B" represent the interfaces at the two ends of
16MCX(Right angle) UHF Male — UHF Female
the cable respectively 3BQ0031
(right angle)
Cable length can be customized
3BQ0032 UHF Female — UHF Female
Customize special cables available Lemo mini
3BQ0033 BNC Male — 2×BNC Female
* Indicates that the cable is the original Lemo connector

3BQ0024 3BQ0025 3BQ0026


Cable Connector Type Length Cable Connector Type Length
Code Cable Code Cable
No. A // B (m/ft) No. A // B (m/ft)

1GC0017 BNC(Q9) BNC(Q9) RG174 1.8 / 6 1GC0001


Lemo-00(C5) Lemo-00(C5) RG174 1.8 / 6
1GC0016 BNC(Q9) BNC(Q6) RG174 1.8 / 6 1GC0461 *
Single
1GC0013 1GC0002
BNC(Q9) Lemo-00(C5) RG174 1.8 / 6 Lemo-00(C5) Microdot(L5) RG174 1.8 / 6
1GC0450 * 1GC0319 *
1GC0015 1GC0089 BNC(Q9) x2 BNC(Q9) x2 RG174 1.8 / 6
BNC(Q9) Lemo-1(C9) RG174 1.8 / 6
1GC0441 * 1GC0039 BNC(Q9) x2 BNC(Q6) x2 RG174 1.8 / 6
1GC0451 BNC(Q9) Lemo-1(Waterproof) RG58 1.8 / 6 1GC0027
BNC(Q9) x2 Lemo-00(C5) x2 RG174 1.8 / 6
1GC0452 BNC(Q9) Lemo-1 Coupling RG174 1.8 / 6 1GC0462 * 3BQ0027 3BQ0028 3BQ0030
1GC0453 BNC(Q9) Lemo mini RG178 1.5 / 4.9 1GC0155
BNC(Q9) x2 Lemo-1(C9) x2 RG174 1.8 / 6
1GC0018 BNC(Q9) Microdot(L5) RG174 1.8 / 6 1GC0463 *
1GC0502 BNC(Q9) UHF(Waterproof) RG58 1.8 / 6 1GC0028 BNC(Q9) x2 Microdot(L5) x2 RG174 1.8 / 6
Single 1GC0455 BNC(Q9) 16MCX(Right angle) RG174 1.8 / 6 1GC0464 BNC(Q9) x2 Lemo mini x2 RG178 1.5 / 4.9
Dual
1GC0007 1GC0152
Lemo-1(C9) Lemo-1(C9) RG174 1.8 / 6 Lemo-1(C9) x2 Lemo-1(C9) x2 RG174 1.8 / 6
1GC0456 * 1GC0465 *
1GC0457 Lemo-1(C9) Lemo-1(Waterproof) RG58 1.8 / 6 1GC0024
Lemo-1(C9) x2 Lemo-00(C5) x2 RG174 1.8 / 6
1GC0458 Lemo-1(C9) Lemo-1 Coupling RG174 1.8 / 6 1GC0466 *
1GC0006 1GC0025
Lemo-1(C9) Lemo-00(C5) RG174 1.8 / 6 Lemo-1(C9) x2 Microdot(L5) x2 RG174 1.8 / 6
1GC0442 * 1GC0467*
1GC0008 1GC0468 Lemo-1(C9) x2 Lemo mini x2 RG178 1.5 / 4.9
Lemo-1(C9) Microdot(L5) RG174 1.8 / 6 3BQ0031 3BQ0032 3BQ0033
1GC0443 * 1GC0122
Lemo-00(C5) x2 Lemo-00(C5) x2 RG174 1.8 / 6
1GC0500 1GC0469 *
Lemo-1(C9) UHF(Waterproof) RG58 1.8 / 6
1GC0501 * 1GC0106
Lemo-00(C5) x2 Microdot(L5) x2 RG174 1.8 / 6
1GC0460 Lemo-1(C9) Lemo mini RG178 1.5 / 4.9 1GC0470 *

77 UT Probes UT Probes 78
SCANNERS
Product

Scanners FC Series
FC-01
PA+TOFD Scanner
DopplerFC-01typePA+TOFD welds scanner is suitable for pipe butt weld
inspection with diameter over 6"(150mm) by axial direction, and flat butt weld
inspection. Combine with four probe clamps & one wheel type encoder. Free
collocation of PA probes & TOFD probes by inspection needs.

Parameter
Range Circumferential: Φ6"(150mm)~flat
Dimensions 426*110*125mm
Encoder Step 48steps/mm
IP Level IP67
Operating Temp -10℃~50℃

FC-26
Longitudinal Weld Scanner

Features
FC-26 scanner can be used for stainless steel pipe, aluminum pipe,
aluminum plate and steel plate,etc. The scanner with four vacuum
suckers, adsorption on workpiece via dragging handle to move probe,
simple and stable on operation
The pipe diameter can be customized according to requirements, and the
applicable range of pipe diameter is 500mm to flat
The length can be customized, up to 1500mm
Different clamping tools can be customized according to selected probes

Scanners 80
FC-02、FC-02+ FC-29
The FC29 scanner supports the simultaneous installation of one group
of TOFD probes and two groups of PA probes. The scanner body is
composed of four individually movable magnetic wheels and a clamp
with springs, and is equipped with a rechargeable laser to indicate the
center position of the probe, avoiding misalignment during scanning.

Features
Scope of application: Pipe circumferential weld workpiece with a
diameter greater than 150mm and flat butt weld workpiece
The standard length of the scanner is 476mm, and the center
FC-02 FC-02+ distance can reach 220mm when using TOFD probes; When space
is required, the total length can be customized
PA/TOFD (FC02) scanner support curvature adjustment, applicable Features: FC-02+ scanner is based on the model: FC-02, with The clamping frame can hold wedges with a width of 22-44mm
to detection for pipe and plate in direction of circumferential and extra 1~4 probe clamps, allows to clamp maximum 8 Phased Four magnetic wheels can attach the scanner to the ferromagnetic
axial. Pressure regulator ensures wedge closely attach to work Array or TOFD probes, which is suitable for multi-groups of detection surface
piece for an effective detection. By equipped with reliable brake Phased Array or TOFD inspection requirements. The encoder is IP67 and has a resolution of 22.1steps/mm
device, the scanner can firmly stay at any position. By simple
operation, most of scanning functions can be achieved manually.
Scanner can be assembled with 4 probes according to detection
Standard Kits
requirement (PA / UT), convenient assembly and disassembly. Scope of application: Same as FC-02
Standard configuration: Added four variable angle probe FC-30
The FC30 scanner is one of the best manual scanners for single axis coding detection of pipeline circumferential welds. The standard
configuration of the scanner can support clamping four probes. The mounted probe can be either phased array probes or TOFD probes .
The probe holder is optimized to operate without tools, saving time when replacing and adjusting probes and wedges.

Features

The end face gear type aluminum frame can maintain overall
rigidity and stability, and can also improve the coupling effect
Parameter FC-02Parameter FC-02+Parameter
between the probe and the pipeline in pipeline circumferential weld
Circumferential: Φ6"(150mm)~flat Circumferential: Φ6"(150mm)~flat
Range detection
Axial: Φ17"(425mm)~flat Axial: Φ17"(425mm)~flat
The magnetic wheel is glued for smoother use
Dimensions 446*182*128mm 446*476*139mm The coupling agent supply joint is integrated with the scanning
Encoder Step 48 steps/mm 48 steps/mm frame, which saves more space
IP Level IP 65 IP 67 Scope of application: Pipeline workpieces with a diameter greater
-10°C~50°C -10°C~50°C
than 114mm
Operating Temp
The total width of the scanning frame is 450mm, and different
Clamp Width of Wedge 32~48mm 32~48mm
lengths of crossbars can be customized according to needs

81 Scanners Scanners 82
MOS-03
MOS Series Mouse Type PA/TOFD Dual Probes Scanner
Doppler MOS-03 mouse type scanner is designed for bilateral simultaneous inspection
MOS-01 of plate butt welds by using dual Phased Array probes, or single group of TOFD
inspection. Equipped with a laser guide, to ensure when traveling along the weld
Mouse Type Girth Weld Scanner center-line during inspection. Wedge width range: 22mm~42mm.

Doppler MOS-01 mouse type scanner is designed for recordable inspection of


circumferential above Φ100mm pipe girth welds and plate butt welds by Parameter
using PA probe. Scope of application: Plate butt welds
Scanner size: 350*182*43mm
Encoder step: 38 steps/mm
Features Ingress protection ratting: IP67
Uses the imitation mouse ergonomics design, the operation is convenient and comfortable
Encoder hidden in the "mouse" can prevent the encoder from slipping, resulting in data loss, but also enhance the life of the encoder
"Mouse" is equipped with four strong magnetic wheels and torsion spring, which can make the phased array probe and the workpiece
surface closely adhere to ensure the coupling effect
It can change the clamping direction of the probe at 90 degrees, compatible with "left and right scan" and "front and back scan” MOS-04
Chain Scanner for Large Pipelines

MOS-04 is suitable for circumferential weld detection of large diameter pipe. The scanner is easy to assemble and operate, and can be quickly
disassembled. MOS-04 scanner can clamp two PA + two TOFD probes simultaneously for weld scanning. It is suitable for circumferential weld
scanning of large pipes with diameter ranging from 8"(203mm) ~ 48"(1219mm). The scanner with manual or automatical operation options.
MOS-02 Wedge width range: 22mm-42mm.
Mouse Type TKY Conner Weld Scanner
Parameter

Doppler MOS-02 mouse type scanner is designed for recordable inspection of TKY conner welds by using single Phased Array probe. Wedge Girth Range Φ203mm~Φ1219mm

width range: 22mm~42mm. IP Level IP65

Storage Temperature -20°C~ +60°C

Operating Temperature -10°C~ +50°C


Features
Using mouse type ergonomic design, smart and comfort to operate
Conceal Design of Encoder, more beneficial to prevent data loss of
encoder track-slipping, and extend the lifetime of encoder
MOS-02 includes 4 strong magnetic wheels, combines pressure springs
to make sure tightly closefit between Phased Array probe and workpiece
surface, and make sure sufficient coupling effects
The probe clamping is 90 ° direction adjustable, to perform lateral
scanning and vertical scanning
MOS04 -DD

83 Scanners Scanners 84
MOS-05 MOS-20
PE Pipe Weld Scanner Simple Scanner
The MOS05 scanner is mainly used for the detection of PE pipe butt
joints. The main body is composed of detachable chains, clamping
frames, and encoders. The scanner is divided into two types: hot melt Used for butt welds for pipes and plates
and electric melt, which are respectively suitable for the detection of PE Used for pipeline corrosion and plate corrosion detection
pipe hot melt butt joints and electric melt butt joints. Small width, suitable for narrow space detection
Scope of application ≥ OD150mm
Features Waterproof rating: IP67

Scope of application: PE pipe with a diameter greater than 60mm,


can be matched with different number of chains according to
requirements Inspection of PE pipe Inspection of PE pipe
It is necessary to first determine the model of the probe and wedge hot melt butt joint electric fusion butt joint
according to the scanning process, and then determine the size of
the clamping frame MOS-07
The screw locking mechanism can make the scanner tightly adhere
to the surface of the workpiece, ensuring good probe coupling Pipe Seat Weld Scanner
Encoder protection level IP67, resolution 23.1 steps/mm
MOS07-DD Automatic
Suitable for welding seam detection of nozzle at 90°
MOS-40 Including angle coding and position coding dual-axis encoder, can accurately locate the
position of probe relative to the weld by sofeware
Dual Probes Spiral Welded Pipe Scanner (Axial or Girth Welding Compatible) With the phased array instrument software, the cross-sectional diagram of each
scanning position can be displayed in real time to assist in the determination of defects
Doppler MOS-40 mouse-like dual probes scanner is mainly used to spiral welded pipe welding inspection, To perform dual PAUT probes The small magnetic & automatic crawler drives the scanner to scan in the axial direction
encoded inspection or TOFD encoded inspection to Axial or Girth welding, also flat butt welding. Each probe angle is adjustable, mouse of the branch pipe, controlled by the handle button, and easy to operate
wheels are adjustable alone with the pipe size. It’s compact and easy to handle. Detection scope: φ100mm ≤ outer diameter of branch pipe ≤ φ300mm, outer diameter
of main pipe ≥ φ600mm

Parameter

Axcial, Girth: OD≥Φ200mm


MOS07 Manual
Range
Spiral Welded: OD≥Φ500mm Suitable for welding seam detection of nozzle at 90°
Dimensions 282*243*82mm Including angle coding and position coding dual-axis encoder, can accurately locate the
Encoder Step 32 steps/mm position of probe relative to the weld
The chain link number of the scanner can be adjusted according to the outer diameter
IP Level IP64
of branch pipe
Operating Temp -10℃~50℃
With the computer, the cross-sectional diagram of each scanning position can be
Wedge Width Range 22~48mm displayed in real time to assist in the determination of defects
Detection scope: φ100mm ≤ outer diameter of branch pipe ≤ φ300mm, outer diameter
of main pipe ≥ φ600mm

85 Scanners Scanners 86
CRS-15 Narrow Chains with Quick Disassembly
CRS Series Chain Scanner for Small Pipes

DopplerCRS-15 scanner is mainly used to pipe OD 0.8"(20mm) to 4.5"(114.3mm)girth welding PAUT. Single or twin chains optional,
CRS-7 / CRS-8 Tool Free Assembly width of each chain is only 36mm, which could be applied to limited clearance with special probe.
Chain Scanner for Small Pipes

Doppler CRS chain scanner is mainly used to inspect girth welding of pipes OD 0.8"(20mm) to 4.5"(114.3mm), one sided or two Parameter
chains two sided are optional. Range Φ0.8"(20mm)~Φ4.5"(114.3mm)
Encoder Step 100 steps/mm
Width 36mm

Parameter Height 17mm

Range Φ0.8"(20mm)~Φ4.5"(114.3mm) IP Level IP65

Encoder Step 100 steps/mm Operating Temp -10℃~50℃

Width 55mm
Height 12mm
IP Level IP65
Operating Temp -10℃~50℃

*The latest quick release patented design chain link,


quick change of pipe diameter with bare hands and tools

CRS-7 CRS-8

87 Scanners Scanners 88
CRS-25
Chain Scanner
DSC Series
DSC-06
Applicable range OD50-300mm middle and small diameter circumferential
butt girth weld phased array detection,can choose a single PA probe Corrosion Scanner
detection and two PA probe bilateral detection according to the detection
requirements; chain section can be quickly disassembled and assembled, Material or corrosion inspection for large pipe and plate
easy to operate. Can use 64 or 128 elements PA probe,water filling as a wedge
Wheel encoder to record data
Optional magnetic wheel or rubber wheel
Probe height adjustable

DSC-06 Scanner Parameters


Circumferential motion Φ127mm~ flat

Encoder IP Level IP 65
Storage Temperature -20°C~ +60°C
Operating Temperature -10°C~ +50°C

DSC-11
CRS-34 PE Pipe Weld Scanner
Scanner for Small Pipes
The scanner is used to inspect electric fusion joint of PE pipe.
The CRS-34 scanner is used for small diameter pipe circumferential welds
The joint fully water immersed, no need remove its surface
inspection with the narrowest space required. Two probes can be installed,
and the outgoing wires of the probes need to be customized. Both groups of lettering, pointer and terminal. Each scanner size only for a
probes adopt a spring preloaded structure, with good coupling effect. The single specification. In diameter range 30~100mm to customize
minimum distance between the front edges of the wedges can be 6mm, and scanner size and water layer height according to joint
the maximum distance is 16mm. The scanner can be used with a wall specification. This scanner is easy to be installed and operated.
spacing greater than 25mm, and the distance between the weld and the end
face of the obstruction should be greater than 25mm.

89 Scanners Scanners 90
DSC-03 DSC-08
Automatic Crawler Multi-functional Automatic Crawler
DSC-08 multi-functional automatic crawler is suitable for pipes which OD are grater than 6", or plate welding. 64 or 128 element water
Specification column probes are optional to perform corrosion / basic material inspection. 32 or 16 element probes are optional to perform girth welding
two-sided inspection. Remote control available to move forward and backward, as well as to control the guide screw to move to left and
Real-time acquisition of working environment images right (500mm).
Displacement reciprocating accuracy error ≤ +/-1mm
Speed accuracy error < 5%
When the wall thickness of bare metal magnetic workpiece
in vertical direction is more than 20 mm, it can carry 20KG
Parameter
Circumferential motion applicable range φ800mm ~ flat, axial
Circumferential motion Φ6" (152.4mm)~flat
motion applicable range φ500mm ~ flat
Encoder Step 28.3 steps/mm
Measuring the thickness of workpiece (≥ 5mm)
IP Level IP65
Speed range: 20mm/s ~120mm/s
Motion speed of power arm is 10 mm/s ~130 mm/s Storage Temperature -20°C~ +60°C

Motion control mode: Operating Temperature -10°C~ +50°C


Free motion model Maximum speed 39 mm/s
Displacement motion mode Minimum speed 8 mm/s
Two-axis scanning mode: raster scanning/sawtooth scanning Maximum load on the vertical plane 6kg

Axial motion Φ1500mm~flat

Features
Phone WIFI + wired remote controller
Support all orientation movements
Multi-probe clamp modes, welds compatible
Base material & corrosion inspections

Application
Weld detection of large tank
Flat plate weld detection
Base material testing
Corrosion detection
Ultrasound thickness measurement

91 Scanners Scanners 92
DSC-27 DSC-28
Guide Rail Scanner for Pipeline Multi-functional Automatic Crawler
Guide rail scanner for circumferential weld can realize remote control. Handle control via wire or wireless, DC 24V power supply. The The DSC 28 multi-functional automatic crawler is a remote-controlled, magnetic wheel scanner, can run freely on ferromagnetic
guide rail design can ensure the distance between probe and weld remain constant, to realize rapid and automatic inspection for workpieces to realize ultrasonic detection. It is applied to large tank and pipeline weld detection, plate weld detection, material
circumferential weld. detection, corrosion detection and ultrasonic thickness measurement.

Application
Used for regular hard pipes, run freely on rusty, residual or frozen pipes surface Application
Minimum thickness of workpiece: 3mm
Outer diameter range of pipeline: OD ≥ 430mm The crawler can run upside down on smooth metal wall.
Vertically runs on wall with coating thickness less than 0.5mm.
Horizontally runs on wall with coating thickness less than 1 mm
Runs freely on rusty, residual or frozen pipes surface
Features Minimum thickness of workpiece: 3mm
Step of encoder: 24steps / mm Circumferential inner diameter range: ID ≥ 610mm
Repeated positioning accuracy: ± 1mm Circumferential outer diameter range: OD150mm ~ flat
Adjustable speed: 5~100 mm / sec Axial outer diameter range: OD 300mm ~flat
Protection: NEMA 4, IP65
Operating temperature: - 20 ° C ~ +60 ° C
Power supply: 220V AC or 24V DC
Features

Step of encoder: 9.37steps/mm


Left and right moving shaft encoder: 23.2steps/mm
Repeated positioning accuracy: ± 1mm
Protection: NEMA 4, IP65
Operating temperature: - 20 ° C ~ +60 ° C
X-axis speed: 0 ~ 120 mm / sec
DSC-02 (For different loads and working conditions,
Simple Scanner the maximum speed will be limited)
Power supply: 220V AC or 24V DC
The main body of the DSC02 scanner is composed of four magnetic wheels and a
clamping frame with springs. It can be installed with 128 or 64 array element
linear array probes. The overall device is compact and portable, with a wide
range of applications. It can be used for corrosion and weld detection of pipe
workpieces with a diameter of 800mm or above, as well as base material
detection of flat workpieces.

93 Scanners Scanners 94
FC-XY02-DD
FS Series XY Dual-axis Automatic Scanner
Doppler XY dual-axis automatic scanner can be used for automatic detection of
composite plate, aluminium plate and steel plate by ultrasonic phased array. The
FS-04 scanner uses four vacuum suckers, easy to operate, stable and reliable. Two DC motors
Corrosion Scanner drive scanning axis and stepping axis to do two-dimensional scanning, which can set
scanning step and scanning area to realize automatic scanning quickly. 64 or 128
7.5S64-1.0x10 flexible phased array probe+water jacket,small pipe corrosion element probes can be selected with wedge or water jacket for base metal detection,
detection, water kackets need to based on pipe OD, water jacket application X/Y dual-axis encoder can do two-dimensional C-scan imaging. Effective scanning area
range OD+/-3mm 800mm*300mm, can customize different effective scanning areasaccording to specific
Suitable for corrosion detection of small diameter pipe OD40mm~150mm inspection needs.
The scanner is equipped with encoder, and the magnetic wheel absorbs the
steel pipe with stable coupling and simple operation Features
Strong applicability. It only needs to change water jacket for different pipe
Applicable for composite plate, aluminium plate and steel plate
diameter, no need to change probe
64 or 128 element probes can be selected with wedge or water jacket for base
metal detection
Effective scanning area 800mm*300mm, can customize different effective scanning
areasaccordingtospecificinspection needs
FS-05 Use vacuum suckers, easy to operate, stable and reliable
Corrosion Scanner Can set scanning step and scanning area to realize automatic scanning quickly
X/Y dual-axis encoder can do two-dimensional C-scan imaging
7.5C64-1.0x10 PA concave probe + water jacket. Water jacket change
according to pipe OD, application range OD+/-3mm
Suitable for corrosion detection of small diameter pipe (OD40mm~150mm)
The scanner is equipped with encoder, and the magnetic wheel absorbs the
steel pipe with stable coupling and simple operation

ENC-10
FS-06 Wheel Encoder
Elbow Corrosion Scanner The Doppler ENC-10 wheel encoder is mainly used with single PA probe for pipe and
Applicable pipe diameter range: elbows above OD102mm plate welds inspection. The structure is simple and convenient, it can be directly
Scanning device with encoder, C scan imaging available connected to the wedge, and according to the detection process, the direction of the
The magnetic wheel is adsorbed on the steel pipe and the coupling is probe can be changed, which is capable to perform scan forward or backward on the
stable, simple operation left or right of welding.
The flexible probe has strong applicability. It only needs to replace the
water jacket to detect different pipe diameters, without replacing the probe
Waterproof registration: IP67

95 Scanners Scanners 96