0% found this document useful (0 votes)
59 views1 page

Details of Half-Round and U-Channels (Type A - With Masonry Apron)

The document provides details for constructing berms including specifications for materials like concrete, masonry, rebar mesh and noting requirements for dimensions, slopes, and joints.

Uploaded by

liu2011jubo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
59 views1 page

Details of Half-Round and U-Channels (Type A - With Masonry Apron)

The document provides details for constructing berms including specifications for materials like concrete, masonry, rebar mesh and noting requirements for dimensions, slopes, and joints.

Uploaded by

liu2011jubo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

BERM WIDTH VARIES ( 1000 MIN.

)
80 x 60 x 2.2 DIA. HANDRAILING
GALVANIZED AND PVC ( SEE STD. DRG. NO. C2103 )
COATED DOUBLE TWISTED
WIRE MESH 50 THICK MASONRY FACING ON 50 MIN. THICK CEMENT MORTAR 200
( SET IN 1 : 3 CEMENT / SAND ), OR 75 THICK CONCRETE APRON,
AS SPECIFIED; ALL TO BE OMITTED IF THIS AREA IS SPRAYED CONCRETE

1000
EXTENT OF WIRE MESH SHALL
BRUSHED FINISH OR AS BE 1 500 OR BERM WIDTH
75 THICK OTHERWISE DIRECTED 25 x 25
WHICHEVER IS THE LESSER
CONCRETE SLAB CHAMFER
25 x 25
150 CHAMFER
A252 MESH

200

300
100
FINISHED SLOPE

50
0
PROFILE
20

FIXING
0

50
300
PIN 1
10

MIN.
H/ 2 POLYTHENE SHEET

E
NON-BIODEGRADABLE
EROSION CONTROL MAT
2
H/

POLYTHENE
50 MIN. THICK SHEET DETAILS OF BERM

B
CEMENT MORTAR
WITH HANDRAILING

15
T H T

2
H/
U-CHANNELS CONSTRUCTED

B
ON BERM
T H T

80 x 60 x 2.2 DIA. GALVANIZED AND PVC


COATED DOUBLE TWISTED WIRE MESH HALF-ROUND CHANNEL
NON-BIODEGRADABLE
EROSION CONTROL MAT
FINISHED NOTES:
SLOPE
PROFILE 1. ALL DIMENSIONS ARE IN MILLIMETRES.
50
0

2. ALL CONCRETE TO BE GRADE 20 / 20.


20

FIXING
0

3. CONCRETE SURFACE FINISH SHALL BE


PIN 50 THICK MASONRY FACING ON 50 MIN. THICK CLASS U2, F2 OR BRUSHED FINISH
CEMENT MORTAR ( SET IN 1 : 3 CEMENT / SAND ), AS DIRECTED.
50 MIN. THICK
OR 75 THICK CONCRETE APRON, AS SPECIFIED;
CEMENT MORTAR
ALL TO BE OMITTED IF THIS AREA IS SPRAYED 4. SPACING OF EXPANSION JOINT IN
CONCRETE CHANNELS, BERM SLABS AND APRONS
TO BE 10 METRES MAXIMUM, SEE STD.
D

DRG. NO. C2413 FOR DETAILS.


15
E

50

5. JOINTS FOR CHANNELS, BERM SLABS,


0
MIN.

APRONS AND WALLS, ETC. TO BE


H/ 2

ON THE SAME ALIGNMENT.


80 x 60 x 2.2 DIA. GALVANIZED
50 DIA. PVC PIPES AND PVC COATED DOUBLE 6. FOR DIMENSIONS T, H, & B, SEE TABLE
2
H/

AT 1500 c / c WITH TWISTED WIRE MESH BELOW.


20

FALL OF 1 ON 3 NON-BIODEGRADABLE
0

7. BIODEGRADABLE EROSION CONTROL MAT IF


WHERE D>600 EROSION CONTROL MAT REQUIRED, SEE STD. DRG. NO. C2511/1E.

8. CONCRETE TO BE COLOURED AS SPECIFIED.


T H T
FIXING PIN
9. CONCRETE U-CHANNEL CAN BE CAST IN-SITU
50 MIN. THICK OR PRECAST CONCRETE SUBJECT TO THE
ENGINEER’S AGREEMENT ON THE DETAILS.
CEMENT MORTAR
10. DETAILS OF EROSION CONTROL MAT AND
U-CHANNELS NOT CONSTRUCTED WESH MESH ON BERM. (SEE STD DRG. NO.
C2511/1E)
ON BERM
I MINOR AMENDMENT. Original Signed 07.2018
NOMINAL SIZE THICKNESS OF MASONRY
T B REINFORCEMENT Original Signed 01.2005
H
H FACING AMENDED.

G MINOR AMENDMENT. Original Signed 01.2004


300 80 100 A252 MESH PLACED F GENERAL REVISION. Original Signed 12.2002
CENTRALLY AND T=100
E DRAWING TITLE AMENDED. Original Signed 11.2001
375 - 600 100 150 WHEN E>650
D MINOR AMENDMENT. Original Signed 08.2001
A252 MESH PLACED C 150 x 100 UPSTAND ADDED AT BERM. Original Signed 6.99
675 - 900 125 175
CENTRALLY B MINOR AMENDMENTS. Original Signed 3.94
REF. REVISION SIGNATURE DATE

DETAILS OF HALF-ROUND CIVIL ENGINEERING AND


DEVELOPMENT DEPARTMENT
AND U-CHANNELS ( TYPE A - SCALE 1 : 25 DRAWING NO.
WITH MASONRY APRON ) DATE JAN 1991 C2409I