CENTRON Device Manual
CENTRON Device Manual
CENTRON® Device
User's Manual
Proprietary Rights Information
This document contains the trade secrets and confidential information of Itron, Inc., which
are not to be divulged to third parties and may not be reproduced or transmitted in whole or
part, in any form or by any means, electronic or mechanical for any purpose, without the
express written permission of Itron, Inc. All rights to designs or inventions disclosed herein,
including the right to manufacture, are reserved to Itron, Inc.
The information contained in this document is subject to change without notice. Itron, Inc.
reserves the right to change the product specifications at any time without incurring any
obligations.
This publication was last updated for the 8.00 release of the PC-PRO+ Advanced suite of
products.
PC-PRO+® Advanced CENTRON® Device User's Manual
Part Number: 428601-270
Itron, Inc. Itron, Inc.
Corporate Headquarters Oconee Electricity Metering
2111 North Molter Road 313-B North Highway 11
Liberty Lake, WA 99019 West Union, SC 29696
U.S.A. U.S.A.
Tel: (509) 924-9900 Tel: (864) 638-8300
Fax: (509) 891-3355 Fax: (864) 638-4950
www.itron.com
Copyright © 1995-2007 Itron, Inc.
All rights reserved.
ii
PC-PRO+® Advanced CENTRON® Device
Itron Contact Information
You can reach Systems Support for Itron Electricity Metering products as shown in the
following table.
Index .........................................................................................................................31
vi
PC-PRO+® Advanced CENTRON® Device
Table of Figures
In This Chapter
PC-PRO+ Advanced Documentation Set...................................................1
About This Manual......................................................................................3
Using This Manual......................................................................................3
Setting System Options and Defaults.........................................................3
Creating a CENTRON Program File ..........................................................4
Communicating With CENTRON Meters ...................................................6
Welcome to the PC-PRO+ Advanced user’s manual for CENTRON device program
components. This manual discusses each of the components that make up a program file for
a CENTRON meter. These program components are available on the Program Editor
Program menu and in the component list on the Program Editor main window.
Before you can program a meter, you must first create the program file. This manual walks
you through the process of configuring each component to create a program file that can be
used to initialize (program) a CENTRON meter.
Use this manual along with the PC-PRO+ Advanced System User’s Manual
which provides additional instructions for setting system defaults and
options, creating program files, and communicating with devices.
User’s Manuals
When you install the PC-PRO+ Advanced software, you can install the online user manuals.
If you choose Complete installation, an Online Manuals item is added to the PC-PRO+
Advanced program group on the Windows start menu. If you choose Custom Setup at
installation, you can turn off the option to install the manuals. The manuals are available on
the installation CD in the Documentation folder.
The user manuals are provided as PDF (portable document format) files that you can view
or print using Adobe Acrobat Reader. The Acrobat Reader software is also included on the
installation CD in the Supporting Files folder.
Also refer to the Technical Reference Guides for the individual meters as
needed for information about meter specifications, hardware, and firmware.
Online Help
You can display the online help by selecting Help | Help Topics from the menu bar or by
clicking the Help button on a dialog. For more information about using the help refer to the
PC-PRO+ Advanced System Online User’s Manual.
Help Files
User's Manuals
If you change the location for installing the PC-PRO+ Advanced software, these locations
will change also.
2
PC-PRO+® Advanced CENTRON® Device
Introduction to CENTRON® Program Components
The following table describes the level of access to the meter provided by each CENTRON
device security code.
Previous Security The last security code used to log on to the device. This code is not
Code programmed into the device.
Refer to the PC-PRO+ Advanced System User’s Manual for instructions for defining
Security Codes and other system options.
4
PC-PRO+® Advanced CENTRON® Device
Introduction to CENTRON® Program Components
Some site-specific information, such as unit ID, can be added to the program file at the time
you program the meter.
Refer to the PC-PRO+ Advanced System Online User’s Manual for additional instructions
for creating and editing program files.
For detailed information about each program component, refer to the PC-
PRO+ Advanced online user’s manual for the device type or click the Help
button on each dialog.
6 After you finish defining all program components, select File | Save or File | Save As to
permanently update the file in the database.
You are prompted to name the file.
7 Enter a maximum or 30 characters for the new Program Name and a value from 1 to
9999 for the Program ID.
The program name and program ID must be unique in the system for each
device. Different devices can have the same program ID, but not the same
name.
You must configure PC-PRO+ Advanced COM ports and modems after you
install PC-PRO+ Advanced before you can log on to a meter. For more
information refer to Chapter 2 of the PC-PRO+ Advanced System User’s
Manual.
For information about initializing CENTRON devices, see Initializing CENTRON Meters
(on page 23).
For information about reconfiguring CENTRON devices, see Reconfiguring the CENTRON
(on page 27).
6
PC-PRO+® Advanced CENTRON® Device
CHAPTER 2
In This Chapter
Adding a Program Description....................................................................8
Defining the Device Operation....................................................................9
Selecting a Time of Use Schedule ...........................................................10
Specifying the Communications Configuration.........................................11
Specifying Device Multipliers....................................................................12
Selecting Display Options.........................................................................13
Selecting a Display Schedule ...................................................................13
Selecting Displayable Errors ....................................................................15
Defining Normal Mode Register Operation .............................................16
Defining Test Mode Register Operation ..................................................17
Configuring Load Profile Options..............................................................18
Defining the Output Configuration ............................................................19
Configuring Self Read Options .................................................................20
Configuring Service Options.....................................................................21
Entering User Data ...................................................................................22
This chapter provides instructions for using PC-PRO+ Advanced to configure the individual
components of a CENTRON meter program file. The program file is used to program a
CENTRON meter for operation at a specific site.
You must use the Display Editor application to create a Display File before
you can save a CENTRON program file. You may choose to create the
Display File before you start configuring the program file. For more
information refer to the Display Editor online help or the PC-PRO+
Advanced System User’s Manual.
For Time of Use meters, you must use the TOU Calendar Editor application
to create the TOU schedule file before you can configure a program file for a
TOU meter. For more information refer to the TOU Calendar Editor online
help or the PC-PRO+ Advanced System User’s Manual.
When you create a new program file, you are prompted to select the device type the
program will support. Once you select the device type, the configurable components for the
device are listed on the left side of the Program Editor window. This list of components is
also shown on the Program Menu.
Create the program file by going down the component list sequentially and configuring the
options for each of the program file components. When you have configured all
components, save the program file (File | Save). For more information about creating
program files, refer to the PC-PRO+ Advanced System User’s Manual.
The sections in this chapter describe the configuration options for each program file
component for a CENTRON device.
You will enter the program ID and name during the save operation. The date
created and date last modified are entered automatically. The description is
not downloaded to the meter.
To add a description
1 From the Program menu, choose Description.
The Description dialog is displayed.
2 Enter a description for the program.
3 Click OK.
8
PC-PRO+® Advanced CENTRON® Device
CENTRON Program Components
Electronic Detent
Check this box to restrict the CENTRON to only metering energy flow to the customer.
Only delivered watt-hours are measured. Received watt-hours are ignored. This has the
same effect as a detent mechanism on an induction watt-hour meter.
If you do not check this box, the meter is not detented. Both delivered and received energy
are shown as delivered energy.
Note: If this box is not checked, Last Season Registers are disabled in the meter to allow
additional space for the TOU calendar.
You must enable TOU in the Device Operation program component before
you can select a Time of Use schedule for the program file.
10
PC-PRO+® Advanced CENTRON® Device
CENTRON Program Components
Browse
Click the Browse button to select the TOU schedule.
Transformer Ratio
Enter the transformer ratio to use when calculating energy and demand readings. You can
set the transformer ratio equal to the CT ratio times the PT ratio of the installation for
primary read meters. Valid values are 0.001 through 9999.9.
12
PC-PRO+® Advanced CENTRON® Device
CENTRON Program Components
2 For Canadian installations, the Nameplate Multiplier field appears on the dialog. Enter
the nameplate multiplier value you want to assign to the meter.
3 Click OK.
Scroll time is the number of seconds that each register quantity will be displayed before
scrolling to the next quantity.
You must select a display schedule before you can save a program file.
Browse
Click the Browse button to select the Display file.
14
PC-PRO+® Advanced CENTRON® Device
CENTRON Program Components
Edit
Click the Edit button to define the action that will be triggered when the error occurs. The
options are as follows:
Ignore–Switch on (enable) the diagnostic check, but disable meter display of the
diagnostic results. The diagnostic is functioning and the diagnostic counter is
incremented by one each time the diagnostic is triggered, but no results are
displayed.
Lock–Enable (switch on) the diagnostic check and program the meter to lock
(freeze) the display on the diagnostic error when the diagnostic is triggered.
Scroll–Enable (switch on) the diagnostic check and program the meter to display
the diagnostic error during the one second display off time for Normal or Alternate
Mode display cycles.
Another dialog prompts you for the display action for the error you selected.
3 Select the desired display mode.
4 Click OK.
16
PC-PRO+® Advanced CENTRON® Device
CENTRON Program Components
Number of Subintervals
Enter the number of subintervals. The interval length divided by the subinterval length is
equal to the number of subintervals. Valid entries are from 1 to 10 and must be evenly
divisible into the demand interval length. For block demand, the number of subintervals is 1.
Number of Subintervals
Enter the number of subintervals. The interval length divided by the subinterval length is
equal to the number of subintervals. Valid entries are from 1 to 10 and must be evenly
divisible into the demand interval length. For block demand, the number of subintervals is 1.
18
PC-PRO+® Advanced CENTRON® Device
CENTRON Program Components
Memory Size
This field applies to the CENTRON C1SL only. Select the amount of mass memory actually
being used for recording Load Profile data. Valid selections are 0 to 32K, in 1K increments.
Use this option to program the device to read or freeze its registers at a predetermined time.
This can be at the time of a demand reset (thus storing previous billing values) or based on a
defined frequency (thus providing capabilities such as calendar month midnight reads).
Additionally, you can specify that a demand reset should be automatically performed by the
device after a self read is done.
20
PC-PRO+® Advanced CENTRON® Device
CENTRON Program Components
Line Frequency
Select the frequency of the line signal. You can select either 50 or 60 Hz.
22
PC-PRO+® Advanced CENTRON® Device
CHAPTER 3
In This Chapter
Initializing CENTRON Meters ...................................................................23
Selecting CENTRON Programming Options............................................23
Initialization Prompt-For Dialogs...............................................................24
This chapter describes the processes of defining CENTRON Programming Options and
initializing CENTRON meters including the initialization prompt-for dialogs.
When you initialize a meter, you are prompted to enter device-specific information for the
individual meter based on the programming options previously defined for the device type.
For information about the Prompt-For dialogs, see Initialization Prompt-For Dialogs (on
page 24). Refer to Reconfiguring the CENTRON (on page 27) for related information about
reconfiguring the meter.
When you initialize a meter, PC-PRO+ Advanced presents a series of prompt-for dialogs
that allow you to enter the site-specific values for the individual meter. The items selected
on the Programming Options dialogs determine which system prompts are displayed when
you initialize a CENTRON meter.
Refer to the PC-PRO+ Advanced System User’s Manual or the System Manager online help
for instructions for defining Programming Options and other system settings.
Examples of the CENTRON initialization prompt-for dialogs and field descriptions are
given in the following topics:
Prompt-For: Programming Data 1 Dialog (on page 24)
Prompt-For: Programming Data 2 (Profile Pulse Weight) Dialog (on page 25)
Prompt-For: I/O Board Configuration Dialog (on page 26)
The unit ID source (user supplied, meter ID, or load research ID) is defined
in the CENTRON Programming Options. For more information see
Selecting CENTRON Programming Options (on page 23).
24
PC-PRO+® Advanced CENTRON® Device
Initializing CENTRON Devices
Load Research ID
The Load Research ID is a unique identifier up to 14 characters long used to identify the
load profile to the translation system.
Normal Mode Kh
The watt-hour meter constant, or Kh, is the energy represented by the equivalent disk
revolution. The value entered may be used for the display, to program the test LEDs, to
control the watt disk emulator, and other functions during normal mode operation.
Transformer Ratio
Enter the transformer ratio to use when calculating energy and demand readings. You can
set the transformer ratio equal to the CT ratio times the PT ratio of the installation for
primary read meters. The range is 0.001 through 9999.9.
Battery Information
Select either Clear time on battery or Set minutes on battery. If you select Set minutes
on battery, you can enter the number of minutes you want to set on the battery.
26
PC-PRO+® Advanced CENTRON® Device
CHAPTER 4
In This Chapter
Reconfiguration Overview ........................................................................27
Reconfiguring the CENTRON...................................................................27
The Reconfigure option is available on the Communications menu while you are logged on
to a CENTRON meter. You can use the Reconfigure feature to reconfigure selected meter
program components without initializing the meter, preventing a loss of meter data. When
you reconfigure a meter, the program component that is being reconfigured is impacted, but
the other non-related components are not affected.
Reconfiguration Overview
When you reconfigure a device, you select the individual program components to be
reconfigured and no other program components or registers are affected. During the
reconfigure operation you may be prompted to enter the site-specific program values for the
device. For certain components, if a program file is open, the values in the program file are
used to reconfigure the device.
1 Select Communications | Logon to log on to the meter. For more information refer to
the PC-PRO+ Advanced System User’s Manual.
After you have logged on to the meter, the Reconfigure option becomes available on the
Communication menu.
2 Select Communications | Reconfigure.
An example of the Reconfigure dialog for the CENTRON meter is shown below.
The items that are available on this dialog are determined by the device type
and the hardware configuration in the meter.
3 Select the items that you want to reconfigure and then click OK.
4 If you selected I/O Board, the following dialog is displayed.
28
PC-PRO+® Advanced CENTRON® Device
Reconfiguring CENTRON Devices
7 Refer to Table for field descriptions. Click OK to continue with the reconfigure.
8 If you are reconfiguring Load Profile, the following dialog is displayed.
10 If you selected TOU Configuration on the Reconfigure dialog, the following dialog is
displayed.
11 Refer to Table for field descriptions. Click OK to continue with the reconfigure.
12 If you selected Security Codes Configuration on the Reconfigure dialog, the following
dialog is displayed.
13 Enter the new Security Codes. For more information about Security Codes, refer to the
online help or the PC-PRO+ Advanced System User’s Manual.
14 Click OK to continue with the reconfigure.
15 If you selected Unit ID on the Reconfigure dialog, the following dialog is displayed.
16 Enter the Unit ID for this device and click OK to complete the reconfiguration.
The meter is reconfigured based on your selections.
30
PC-PRO+® Advanced CENTRON® Device
Index
C
chapter descriptions • 3
Communicating With CENTRON Meters • 6
Creating Program File • 4
D
defaults • 3
demand reset • 20
Display Editor • 7
Documentation Set • 1
L
line frequency • 21
Load Profile Options • 18
O
Online Help • 2
P
program components • 7
Program ID • 5
Program Name • 5
Programming Options • 23
pulse weight
load profile • 18
S
Security Codes • 4
Self Read Configuration • 20
Self Read Options • 20
System Options • 3
T
TOU Calendar • 7
Transformer Ratio • 12
U
User Data • 22
Using This Manual • 3