This document provides information about a fire detection and suppression control panel module/card. The card displays indications for signals, faults, activations and shutdowns. It includes 16 LED groups and 4 configurable membrane keys. The card can be configured using MxSysCon software and installed in fire alarm panels.
This document provides information about a fire detection and suppression control panel module/card. The card displays indications for signals, faults, activations and shutdowns. It includes 16 LED groups and 4 configurable membrane keys. The card can be configured using MxSysCon software and installed in fire alarm panels.
Card for use in all design variants of the FMZ 5000 fire detection and suppression control panel series. Includes 16 groups with one red and one yellow LED each and 4 membrane keys with freely configurable function. In addition there are 4 connections for uses such as key-operated switches on the front plate. Labeling is by means of sliding labels behind transparent windows - at front plate BBF, one window per zone operating panel, LED group and membrane key.
Product features Application
• Each LED can be configured for indication by steady For displaying individual indications of signals, faults, light, flashing and rapid flashing activations, shutdowns etc. • Each membrane key can be used as a switching Up to 27 cards can be used in one fire alarm panel. actuator or a momentary-contact actuator • All settings are carried out with the MxSysCon Included in delivery configuration program Card, separate or as part of a complete retrofit kit including • No adjustment work is required mounting accessories for installation behind the front plate. Complete retrofit kit 903340 includes: Zone operating panel card 901518 Technical specifications Mounting accessories 904981 Artwork master 50 BBF 903282 Operating voltage 19 V - 29 V DC Quiescent current 10 mA DC Not included in delivery -5 °C to +40 °C Ambient temperature Front plate FMZ 5000 BBF 901733 (+23 °F to +104 °F) Relative humidity max. 95 % (IEC 721-3-3) no condensation Note Mounting On the rear side of the front plate Connected switches/buttons must not be fitted outside the central fire alarm system. Weight 40 g (0.1 lbs) 70 x 113 mm (WxH) Dimensions 2.8 x 4.5 inch (WxH) Approvals / marking See panels The contents of this publication are subject to modifications without notice. All rights reserved. 301-420_030 / AI01_2016en
1/1
Minimax GmbH & Co. KG | Industriestr. 10/12 | 23840 Bad Oldesloe | [email protected] | www.minimax.com