0% found this document useful (0 votes)
16 views5 pages

Room Humidity Temperature Transmitter RHT

The document describes a room humidity and temperature transmitter that measures and converts humidity and temperature to standard 0-10 Vdc or 4-20 mA outputs. It can include optional passive temperature sensors and displays and is used in ventilation, HVAC, and building automation applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
16 views5 pages

Room Humidity Temperature Transmitter RHT

The document describes a room humidity and temperature transmitter that measures and converts humidity and temperature to standard 0-10 Vdc or 4-20 mA outputs. It can include optional passive temperature sensors and displays and is used in ventilation, HVAC, and building automation applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Room Humidity and Temperature Transmitter RHT November 2019

Features
• Humidity and Temperature outputs in same unit

• Humidity output 0-10 Vdc or 4-20 mA

• Temperature output 0-10 Vdc or 4-20 mA

• Passive temperature sensing element


PT1000, PT100, NTC 10K, NTC 20K, NTC 1.8K , NI1000 etc
as option

• With or without LCD display

• Humidity accuracy ± 2% at 20 to 80% rH

• Temperature accuracy ± 0,3K


RHT 010 010
• On request potentiometer

Ordering
__________________________________________________________
Type no. Humidity Temperature LCD Passive
Output Output Display Temp.
Output
___________________________________________________________

RHT 010 010 D RHT 010 010 0-10 Vdc 0-10 Vdc No No

RHT 010 010 D 0-10 Vdc 0-10 Vdc Yes No

RHT 420 420 4-20 mA 4-20 mA No No

RHT 420 420 D 4-20 mA 4-20 mA Yes No

RHT 010 010 XXX 0-10 Vdc xxx (see below) No Yes

RHT 010 010 XXX D 0-10 Vdc xxx (see below) Yes Yes

RHT 420 420 XXX 4-20 mA xxx (see below) No Yes


New LCD display 2019
RHT 420 420 XXX D 4-20 mA xxx (see below) Yes Yes

XXX = Passive temperature sensing element


DIP switch on pcb to select: PT100, PT100 1/3 DIN,
PT1000, PT1000 1/3 DIN,
Relative Humidity, NI1000, NI1000/TK5000,
NTC 1.8K, NTC 5K, NTC 10K, NTC 20K, KTY81-210
Absolute Humidity,
Example:
Dew Point or Humidity output 0-10 Vdc,
Temperature Output 0-10 Vdc,
Enthalpy PT1000 passive temperature sensing element and
Display,
type is : RHT 010 010 PT1000 D

Ventilation Control Products Sweden AB - Phone: +46-31-811666 - E-mail: [email protected] - Web: www.vcp.se
Room Humidity and Temperature Transmitter RHT November 2019

Technical data
Humidity output: 0-10 Vdc or 4-20 mA (3-wire)

Temperature output for active versions: 0-10 Vdc or 4-20 mA (3-wire)

Passive temperature sensing element PT1000, PT100, NTC 10K, NTC 20K NTC 1.8K, NI1000 etc. (option)

Power supply with 0-10 Vdc output: 12-24 Vac or 16-36 Vdc

Power supply with 4-20 mA output: 16-36 Vdc

Sensor element (humidity): Capacitive sensor

Sensor element (temperature): Capacitive sensor

Humidity measuring range: 0 to 100% rH

Humidity accuracy ± 2% at 20 to 80% rH

Temperature accuracy: ± 0,3K (+5°C to 60°C) + 1.5% f.s

Analogue output load 0-10 Vdc: 10 to100 kOhm

Analogue output load 4-20 mA: 50 to 500 kOhm

Operating temperature: 0°C to +50°C

Operating range: 0 to 98% rH

Connection: Screw clamps 1,5 mm²

Casing: Material ABS, Colour RAL 9010

Dimensions Housing (L x W x H): 87,5 x 87,5 x 30 mm

Protection class: IP30

Relative humidity measuring range: see configuration page 4

Absolut humidity measuring range: see configuration page 4

Dew point measuring range : see configuration page 4

Enthalpy: see configuration page 4

Standards:
Directive: 20014/108/EG
DIN EN 61326-2-1:2013

Ventilation Control Products Sweden AB - Phone: +46-31-811666 - E-mail: [email protected] - Web: www.vcp.se
Room Humidity and Temperature Transmitter RHT November 2019

Description
The RHT is room humidity and temperature transmitter measures the humidity and temperature of air.

The room humidity and temperature transmitter RHT converts the measurements humidity and temperature
into standard signals of 0-10 Vdc or 4-20 mA.

Passive temperature sensor PT1000, PT100, NTC 10K, NTC 20K, NTC 1.8K, NI1000 as option

The RHT room humidity and temperature transmitter can be ordered with or without display.

The built-in display on room humidity and temperature transmitter RHT show actual humidity and actual temperature.

The RHT room humidity and temperature transmitters are applied in non-aggressive dust-free ambiences in refrigeration, air conditioning,
ventilation and clean room technology, in interior rooms such as residential rooms, offices, hotels, technical rooms, meeting rooms and
convention centres.

Ventilation Control Products Sweden AB - Phone: +46-31-811666 - E-mail: [email protected] - Web: www.vcp.se
Room Humidity and Temperature Transmitter RHT November 2019

Configuration

Electrical connection

Ventilation Control Products Sweden AB - Phone: +46-31-811666 - E-mail: [email protected] - Web: www.vcp.se
Room Humidity and Temperature Transmitter RHT November 2019

Dimensions

Mounting
Important

In-phase connection is necessary for parallel


operation with 24 VAC in order to avoid
short circuits.

The devices are built for safety extra-low


voltage operation. The technical data from the
The convection must be aligned at the bottom to ensure a flow of air up data sheet apply when connecting the devices.

The sensor should always be mounted on the opposite wall of the radiator. These instruments must be installed by
authorised specialists only! Devices shall only
Ideal mounting height of 1.5 m above the floor. be used for their intended purpose. The
customer has to ensure adherence to the
building and safety regulations and has to avoid
all dangers of any kind.

We reserve the right to make changes in our products without any notice which may effect the accuracy of the information contained in this leaflet.

Ventilation Control Products Sweden AB - Phone: +46-31-811666 - E-mail: [email protected] - Web: www.vcp.se