Design Basis of Fire Fighting Systems

The document defines the design basis for fire water and deluge systems according to codes. It includes scope, codes followed, design principles, and fire pump specifications. Water demand is calculated for two scenarios involving monitors, hoses, and nozzles. Pump specifications are provided.

Uploaded by

kazmi naqash
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
130 views

Design Basis of Fire Fighting Systems

The document defines the design basis for fire water and deluge systems according to codes. It includes scope, codes followed, design principles, and fire pump specifications. Water demand is calculated for two scenarios involving monitors, hoses, and nozzles. Pump specifications are provided.

Uploaded by

kazmi naqash
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

Design Basis of Fire &

Fighting System
Prepared For: NATO

Submitted By:

ISSUED FOR TENDER PURPOSE ONLY

Dated: 05-03-2021
Table of Contents
1- SCOPE OF DESIGN ..................................................................................................................... 1
2- CODES & STANDARDS FOLLOWED ........................................................................................... 1
3- MAIN DESIGN PRINCIPLE .......................................................................................................... 2
4- FIRE WATER & PUMP DEMAND CALCULATIONS………………………………………………………………....3
1- SCOPE OF DESIGN
This document defines the Design Basis for Fire Water system and water deluge system
used for the following purposes:

 Design of Fire Hydrant System.

 Design of Fire Deluge System.

 Design of Beam Detection System.

2- CODES & STANDARDS FOLLOWED


1) Main Yard and Outdoor Fire Hydrants System NFPA - 24 & 26

2) Water Monitors System NFPA - 11

3) Deluge fire Protection System NFPA - 13 & 15

4) Piping & Hose System NFPA - 14(1961 -62 edition)

5) Fixed Water Spray System NFPA - 15

6) Automatic Fire Detection System NFPA - 72(A-E)

7) Water Supply System NFPA - 13,15,20&22

8) Fire Pumps NFPA - 13 & 20

The fire protection system design will be adequate for the site conditions, to provide a
high degree of protection to the plant, equipment's, buildings and employees.

1
3- MAIN DESIGN PRINCIPLE
According to NFPA, the firefighting measures for building and equipment in the plant is as
mentioned in Table 3-1 below:
Table 3-1 List of Building & Structure
Sr. Description a b c d

1 External Buildings of the Plant √

2 Internal Areas of the Plant √

3 Warehouse √ √ √

Note:
a. Fire Hydrant

b. Fire Hose Reel

c. Fire Detection System

d. Fire Water Deluge System

2
4- FIRE FIGHTING WATER & PUMP DEMAND CALCULATION
The source of water for the Fire Water Systems will be the proposed underground water
storage with proposed automatic water make-up line for level control.

Water supply Detail are as under according to the Fire Scenarios:

FIRE SCENARIO (1): 2 Fire Monitor, 1 HOSE REEL and 180 DELUGE NOZZLES ARE
OPERATING.
DENSITY 0.6 GPM/SQFT 24.6 L/MIN MSQ
MAXIMUM COVERAGE AREA 6400 SQFT
PUMP DEMAND 3874 GPM
DISCHARGING SPRINKLER 180 Nos
MAXIMUM SPACING 6 SQ.FT
SINGLE SPRINKLER REQUIRED FLOW 21.52222 GPM 81.48 L/M
ADDITION FLOW ALLOWANCE 2 MONITOR + 1 HOSE 565 GPM
TOTAL PUMP REQUIRED 4439 GPM
WATER RESERVIOR REQUIRED 266340 US GALLONS

FIRE SCENARIO (2): 2 Fire Monitor, 1 HOSE REEL and all 720 DELUGE NOZZLES ARE
OPERATING.
DENSITY 0.6 GPM/SQFT 24.6 L/MIN MSQ
MAXIMUM COVERAGE AREA 6400 SQFT
PUMP DEMAND 15496 GPM
DISCHARGING SPRINKLER 720 Nos
MAXIMUM SPACING 6 SQ.FT
SINGLE SPRINKLER REQUIRED FLOW 21.52222 GPM 81.48 L/M
ADDITION FLOW ALLOWANCE 2 MONITOR + 1 HOSE 565 GPM
TOTAL PUMP REQUIRED 16061 GPM
WATER RESERVIOR REQUIRED 963660 US GALLONS

3
5- REQUIRED FIRE PUMP SPECIFICATIONS

FIRE SCENARIO (1): 2 Fire Monitor, 1 HOSE REEL and 180 DELUGE NOZZLES ARE OPERATING.

Flow Head Quantity


Pump Type
(GPM) (m) (set)

ELECTRIC FIRE PUMP 4500 15.3-Bar 1

DIESEL FIRE PUMP 4500 15.3-Bar 1

JOCKEY FIRE PUMP 300 16.3-Bar 1

 Electric Driven Fire Water Jockey Pump ( 01 No )


o Flow= 68.1 m3/hr. , Head= 16.3 Bar
 Electric Driven Fire Water Pump ( 01 No )
o Flow= 1022 m3/hr., Head= 15.3 Bar
 Diesel Driven Fire Water Pump ( 01 No )
o Flow= 1022 m3/hr., Head= 15.3 Bar

Above 03 x pumps have auto start & stop sequence as per NFPA through pressure
switches installed on main fire water header. During normal scenario electric driven
Jockey Pump maintains the main header pressure.

4
FIRE HYDRANT
SYSTEM

5
FH FH
-8 -9 FHD FH
-1
0
FHD

FHD
FH
-1
1 FHD

FH
-7 201烟火药
制造 及曳光钢芯
压药工房 Hosereel Cabinet
FHD

FHD
FH
202枪弹 -1
装配及弹 2
头装配工 箱变
FHD

FH FHD Hydrants = 33 Nos
- 6 FHD

FH
FHD
FH
- -1 FHD
FH FH
5 FH
FHD
3 -1 -1 Pipe 300mm
-4 4 5
废水处理池
301
Pipe 250mm
FH
-1
8 Pipe 200 mm

FHD
原有靶场
Pipe 150mm

10 FH Pipe 100mm
FH 2

FHD
- FH 熔 -1
47 -1 9
6 压
FH 铅

FHD
-2 FH 工
FH 8 -1
7 房 Auto Targeting Fire Water Monitor = 2Nos
-3
0
FH
-3 2F Automatic Fire Water Monitor = 5 Nos
FH
FHD

PUMP CAPACITY 8,600


FH FH -2

FHD
FHD
GPM FOR FIRE HYDRANT
-4 -3 0
& DELUGE SYSTEM
6 2 FH
-3

FHD
1 10 Manual Fire Water Monitor = 7 Nos

FHD
PU
FH 86 MP
FH FH
- GP 00 W REQ
1 -2

FHD
1 M AT U
E I -2 2

U
FO S 516 R T RED
OF R GA ,0 A 3
FI 60 LLO00 NK
RE M N FH 弹
FI INU S
GH T
TI ES
FH - 27 零
NG -4
5 件 Gate Valve
FHD



FH 工
-3 房
3
FHD

FH FH FH
-4 -2 -2
4 1

FHD
6
FH
-2
9
FH
-3
9 FH
-3
FHD

4
FH
-2

FHD
5

FH
-2
Title:

FHD
FH FH
-3 -2
FHD

FH 5 4
-4 FIRE HYDRANT SYSTEM

FHD
3

Client:
FH
-3
7
FH FH
FH -4 -3
-4 0 6
FHD
1
FHD

FHD

FHD

FH Contractor:
- 38
FHD

FH
-4
2

Date: Ref. No.


27/1/2021

Designed by: Scale:


Naqash Kazmi 1:1
FIRE DELUGE SYSTEM

6
BEAM DETECTION
SYSTEM