SF-C21 Safety Control Unit
SF-C21 Safety Control Unit
Spec Detail
As of April 18, 2020
Specifications and design of the products are subject to change without notice for the product improvement.
Item Specifications
IEC 60947-1, IEC 60947-5-1, IEC 60947-5-2, IEC 60947-5-5, IEC 60947-
Related standards
5-8, IEC 61496-1, IEC TS 62046, ISO 13851
https://www3.panasonic.biz/ac/ae/search_num/index.jsp?c=detail_print&part_no=SF-C21&large_g_cd=2&medium_g_cd=15&small_g_cd=134&s… 1/4
17/4/2020 SF-C21 | Safety Control Unit SF-C21 | Automation Controls | Industrial Devices | Panasonic
100 mA or less
(Note) "Power supply for external" is the power supply for control output /
auxiliary output. The power supplies for internal and external are
insulated.
(Note) The power supply unit connected to this device must satisfy the
conditions below.
- Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10 % or less.)
Current consumption : Power supply
- Power supply unit SELV (safety extra low voltage) / PELV (protected
for external
extra low voltage) conforming to the EMC Directive and Low-voltage
Directive (In case CE Marking conformity is required.)
- Power supply unit conforming to the Low-voltage Directive and with an
output of 100 VA or less
- Power supply unit with an output holding time of 20 ms or more.
- Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing
Mark conformity is required.)
2 inputs x 4, Rated voltage: Same as the voltage of the power supply for
Safety input (IN1 to IN8)
internal
Input voltage: 18 V
Safety input (IN1 to IN8) : ON level
Input current: 3.5 mA
Input voltage: 5 V
Safety input (IN1 to IN8) : OFF level
Input current: 1.0 mA
AUX1: Negative logic of OUT1 / OUT2 (ON when OUT1 / OUT2 is OFF)
Auxiliary output(AUX1 to AUX4)(Non-
AUX2: Negative logic of OUT3 / OUT4 (ON when OUT3 / OUT4 is OFF)
safety output) : Output mode (Factory
AUX3: Reset trigger output (ON under reset release wait condition)
defaults)
AUX4: Lockout output (OFF when lockout)
https://www3.panasonic.biz/ac/ae/search_num/index.jsp?c=detail_print&part_no=SF-C21&large_g_cd=2&medium_g_cd=15&small_g_cd=134&s… 2/4
17/4/2020 SF-C21 | Safety Control Unit SF-C21 | Automation Controls | Industrial Devices | Panasonic
- Maximum load current: 60 mA
- Supply voltage: Same as the voltage of the power supply for internal
- Residual voltage: 2.5 V or less
- Leakage current: 100 μA or less (Including power supply OFF condition)
Interface: RS-485
Communication function (MODBUS Protocol: MODBUS RTU
RTU) Maximum transmission distance: 100 m 328.084 ft
Maximum number of units that can be connected: 8 units (slaves)
Input mode, control mode, output mode, reset mode, auxiliary ou tput
Logic setting function
mode
Pollution degree 2
Environmental resistance:Degree of IP20 (IEC)(must be installed in a control panel with protectio n IP54 or
protection higher)
Shock resistance 147 m/s2 (15 G) 11 ms in X, Y and Z directions for three times each (IEC /
EN 60068-2-27)
Input / output and power supply: Detachable spring cage termina l blocks
Connecting method RS-485: Detachable spring-cage terminal block
USB: MiniB male
https://www3.panasonic.biz/ac/ae/search_num/index.jsp?c=detail_print&part_no=SF-C21&large_g_cd=2&medium_g_cd=15&small_g_cd=134&s… 3/4
17/4/2020 SF-C21 | Safety Control Unit SF-C21 | Automation Controls | Industrial Devices | Panasonic
Material Main unit enclosure: Polycarbonate / ABS polymer alloy
Enclosure: Polycarbonate
Accessories
Product
SFD-CCB7-MU
Number
Product
Bottom cap cable
name
© Panasonic Corporation
https://www3.panasonic.biz/ac/ae/search_num/index.jsp?c=detail_print&part_no=SF-C21&large_g_cd=2&medium_g_cd=15&small_g_cd=134&s… 4/4