1. DO NOT SCALE THIS DRAWING. FOLLOW FIGURED DIMENSIONS.
28 m 2. ALL DIMENSIONS ARE IN Meters ONLY.
3. USE VIBRATED REINFORCED CONCRETE OF MIX M25 25.8 m CONFORMING TO IS:456-2000. 4. USE HYSD BARS OF Fe-500 AS PER IS:1786-1985. 5. MIN. LAP LENGTHS RECOMENDED FOR REINFORCEMENT. 1.2m
6. NOT MORE THAN 50% OF COLUMN REINFORCEMENT SHALL BE
LAPPED AT A PARTICULAR LOCATION. 7. THE STRUCTURE IS DESIGNED FOR G+2 UPPER FLOORS 8. S.B.C. OF SOIL IS ADOPTED AS PER SOIL REPORT 9. PROVIDE CLEAR COVER FOR FOOTINGS=2", COLUMNS=1½", BEAM STIRRUPS= ", SLABS= " 0.94m
10. STIRRUPS SHOULD HAVE STANDARD HOOK AS PER SP-34.
11. THE DIFFERENCE IN LEVELS OF DEPTH OF ADJACENT FOOTINGS 12.3m
SHALL NOT BE GREATER THAN HALF THE CLEAR DISTANCE
BETWEEN THEM. 12. CORRELATE WITH THE RELEVANT DRAWINGS FOR THE NECESSARY 13. ANY DISCREPANCY FROM THE DRAWING SHALL BE BROUGHT TO THE NOTICE OF CONSULTANTS. 14. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH RELEVANT ARCHITECTURAL DWG. 15. CURING SHOULD BE DONE ATLEAST FOR 10 DAYS. 16. STRIPPING TIME OF FORMWORK SHALL CONFORM TO 3.02m 2.82m CLAUSE 11.3 OF IS:456-2000. Name of the Project Construction of Machinery Store Cum Kitchen Room at Mulapadu Cricket Ground CLIENT Andhra Cricket Association Provide STRUCTURAL ENGINEER: Top :3-Ø12mm Civil Enigneering Department, V.R.Sidhartha Engineering College, Bottom :3-Ø12mm Kanuru,Vijayawada Stirrups : 2L-8mm@150mm c/c DRAWING TITLE Plinth Beam Layout Plinth Beam Layout DRAWN SKS DRAWING NO : DESIGNEDBPR REV DATE 25-03-2023 S-CL-04 R0 SCALE 1:100