Anybus X-gateway – PROFINET-IO


Device – Modbus RTU Slave
The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their
connected devices between and PROFINET and Modbus RTU networks.

FAST COPYING OF I/O DATA


The X-gateways primary function is with the fast transfer of cyclic I/O data between the two
networks. This offloads your PLC from working with additional calculations. The gateway acts as a
Device on the PROFINET network and as a Slave on the Modbus RTU network. The data
transmission between the two networks is completely transparent with a maximum data capacity
of 512 bytes in each direction.

EASY CONFIGURATION - NO PROGRAMMING REQUIRED!


The connection between the two networks is quickly set up in the Anybus Configuration Manager
software, included with the X-gateway. No programming skills are needed to set up the X-gateway.
As factory default the X-gateways have a pre-defined I/O size of 20 bytes I/O.

Features and benefits


 Fast copying of cyclic I/O data between PROFINET and Modbus RTU networks (10-15 ms)

Proven and tested with all PLC manufacturers
 Supports up to a maximum of 512 bytes of Input and Output data in each direction

Possibility to build web pages displaying and controlling a factory floor process with data from the other connected network
 Fast, dynamic transfer of fieldbus data to e.g. SCADA/HMI/Enterprise level systems based on Microsoft Windows, via the included
Anybus OPC server
 Optional control status information added to I/O data for diagnostic purposes
 Robust stand-alone housing for use in harsh industrial environments
 Global free technical support and consultancy

PROFINET I/O Device/Slave interface


PROFINET IO Device/Slave settings can be made by importing the provided .GSDML file into engineering tool of the controlling PLC.

Complete PROFINET-IO Soft-Real-Time (RT) communication
 Max 512 bytes of Input and 512 bytes of Output data
 Up to 64 slots / 1 sub slot
 Cyclic data exchange (10 ms cycle time)

Acyclic Data exchange (Record Data Requests)
 Baud rate 100 Mbit/s
 Integrated FTP server provides easy file management using standard FTP clients
 Web server with dynamic data capability and Server Side Include (SSI) capability

Email client with dynamic data capability and Event-triggered email handling

TCP/IP Configuration via DCP (Discovery and Configuration Protocol)
 PROFINET uplink configuration via web interface or .GSDML file
 1x RJ45 network connector

https://www.anybus.com/products/gateway-index/anybus-xgateway/detail/anybus-x-gateway-profinet-io-device-modbus-rtu-slave 1/3
25/08/2023, 08:21 Anybus X-gateway – PROFINET-IO Device – Modbus RTU Slave

Modbus RTU Slave interface


Modbus RTU network address settings made via on-board configuration switches
 Complete Modbus RTU slave functionality
 Max 512 bytes of Input and 512 bytes of Output data
 Modbus diagnostics support

Configuration via on-board DIP switches

Modbus RTU baudrate 12-57,6 kbit/s
 1x D-sub 9-pin female network connector

TECHNICAL SPECIFICATIONS

Dimensions (L•W•H) 114 x 44 x 127mm or 4,49 x 1,73 x 5,00"

Weight 400g or 0,880 lbs

Operating temperature -25 to +65 °C or -13 to +149 °F

Storage temperature -40 to +85 °C or -40 to +185 °F

Power supply 24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector

Current consumption max. 400mA (Typical 200mA)

Enclosure material Aluminium and plastic

Installation position Vertical / Flat*

Galvanic isolation YES, on both BUS/Ethernet side

Mechanical rating IP20, NEMA rating 1

Mounting DIN-rail (EN 50022 standard)

I/O configuration via USB port with Anybus Configuration Manager software

Certifications CE, CULUS, RoHS

File Version Size Read online

Ordering information

Order Code AB7659

https://www.anybus.com/products/gateway-index/anybus-xgateway/detail/anybus-x-gateway-profinet-io-device-modbus-rtu-slave 2/3
25/08/2023, 08:21 Anybus X-gateway – PROFINET-IO Device – Modbus RTU Slave

Included components Gateway


Quick start documentation
USB configuration cable
Power supply not included

Configuration and Anybus OPC server software is available for download

3 year guarantee. For purchasing instructions and terms and conditions, see: How to buy

Copyright © 2020 HMS Industrial Networks - All rights reserved.