Proposed Residential Building Plan To Be Built By

Krishna Kant Kumar , S/o:- Ramdatt Ram ,


Maujja :- Akauna ,Motihari , Thana :- Banjariya,
Distt:- East Champaran(Bihar)
Khata No. :- 2, Khesra No. :-68 & 52,Thana No. :- 104 ,
Raquba.- 2.52 Decimal As/Deed,Scale 1" = 10'
FRONT GUTTER
V2

R.c.c.(1:2:3)4.5"th.

2'-6"
R.C.C SLAB V1
Roof slab as per design.
G.F

BY PASS

7'-6"
R.c.c.(1:2:3)4.5"th.
Roof slab as per design.

100
5000
COARSE SAND

100
TREAD=10" GRAVEL
2'-6"

RISER=6.6"

10'
STEPS=20

100
WIDTH=3'0" BOULDER

R.c.c.(1:2:3)4.5"th.

2500
Roof slab as per design.
10'

100 MM DIA PILE

TREAD=10"
RISER=6.6"
SECTION AT A - A

10'
STEPS=20
WIDTH=3'0"

1200
R.c.c.(1:2:3)4.5"th.
10'

Roof slab as per design. A A

2500

1000
TREAD=10"
RISER=6.6" R.c.c.(1:2:3) 6"th.

10'
STEPS=20
WIDTH=3'0"
2500
10'

R.c.c.(1:2:3)4.5"th.
Roof slab as per design.
DETAILS OF RECHARGEABLE
BORE WELL
TREAD=10"
RISER=6.6" R.c.c.(1:2:3) 6"th.
BOUNDARY DETAIL,S
10'

STEPS=20
WIDTH=3'0"
10'

2"th.D.P.C.at plinth level.


PL
N :- Nij Road 8'-0" Wide ,
Gate S :- Hissa Vishwanath Prasad,
2'-6''

G.L
2'-6"

Ramp
XXXXX E :- Roop Narayan Ram ,
FRONT ELEVATION 1"th.A.P.S.flooring over 3"tk.brick flate soling
over 4.5"th.dry rammed khoaover sand filling & Jagdish Prasad,
ST.CASE SECTION B-B W :-Prabha Devi & Other's ,
W 23'-8" W W 23'-8" W

SL

LS
OP

PO
BEDROOM BEDROOM BEDROOM BEDROOM
W W W W
10'9''X11'0'' 10'11''X11'0'' 10'9''X11'0'' 10'11''X11'0''

D D
D1 B/C
B/C W1
LOBBY 4'0''X4'6''
W1 KITCHEN 4'0''X4'6'' V
D2
V TERRACE
6'5''X6'0'' 10'10''X6'3'' KITCHEN
5'0''X8'6'' D2

38'
38'
BATH LOBBY BATH
V 9'4''X15'11'' V
7'5''X6'0'' 7'4''X6'6''

P O
SL
POOJA
4'7''X7'0''
D D
W1 D1
HALL
14'4''X19'4'' D

MUMTY
BEDROOM
14'3''X9'0''
STAIRCASE
6'11''X15'7''

PO

OP
STAIRCASE

LS

SL
GATE
W 6'11''X15'7''
RAMP
W1

FIRST SECOND & THIRD FLOOR PLAN TERRACE FLOOR PLAN


GROUND FLOOR PLAN

10' SCHEDULE OF OPENING


4 NOS 10 MM Ø TMT BAR (2 TOP + 2 BOTTOM) BEAM SIZE
TYPE DIMENSION
10"x12"
6" 2#12
Extra 3#12TH
2#12
Extra D 3'-6" X 7'-0"
5'-6" 5'
D1 3'-0" X 7'-0"
ELEVATION 3#12 D2 2'-6" X 7'-0"
PLAN
#8@
100
#8@
150
#8@
100
W 5'-0" X 4'-6"
DETAILS OF F/C WALL DESIGN OF LINTEL BEAM DETAIL OF ROOF BEAM W1 3'-0" X 4'-6"
V 2'-0" X 1'-6"
Stiruff 6mm dia @6" c/c
2nos 12mm dia at top 10"x10" R.C.C (1:1.5:3) pillar
SPECIFICATION 2nos 12mm dia crank 10"x12" Gr.Level Beam
1. Foundation 1:1.5:3 Isolated Footing Foundation. (1:1.5:3)
2. Plinth And First Class B/W In CM 1:8 Superstructure
3"Thick C.C 1:2:4 D.P.C With D.P.C Powder. 2nos 12mm dia at bottom
3. Flooring 1" Mosaic Flooring Over 6"D.R.K. 6" thick R.C.C (1:1.5:3)
4. Lintel 6" R.C.C Lintel And Band Over All Wall. 5'-0" 6" thick R.C.C (1:1.5:3)
10" thick R.C.C (1:1.5:3)
5. Roofing 4" R.C.C Slab And Beam 1:1.5:3 Roof Tiles 3''thick local soling
Over R.C.C Slab. 6''thick local sand
6. Wood Work SaL Wood Chaukhat 4"X 3" Size And 1.25" 4' filling
Thick Shutters Doors And Windows.
7. Finishing Two Coats White Washing Over1/4"Cement jali of 10mm. dia tor steel
Plaster 1:4 In Celing And 1/2" Cement Plaster @ 5"c/c in both direction
1:6 Both Sides Of Walls. 6 nos 12mm dia rod
8. Sanitation i). Power Driven Tube Well 4'
ii). Provision Of Septic Tank With Soak Pit As Per Detaile 5" thick concrete
Drawing & 6" X6" Pucca Drain All Side Of Walls. cover to steel
9. Earth Quake Resistant R.C.C Framed Structure. 4'

L
L/4 L/2 L/4 inlet pipe 4" dia outlet pipe 4" dia
8 MM ø (FE500)
10" Thick brick work
DISTRIBUTION BAR in C.M (1:4) with
@7" C/C double coat of cement 5'' P.C.C (1:1.5:3)
l/4

plaster on in sides wall 3''thick local soling


6''thick local sand
filling
10 MM ø (FE500)
SECTIONAL WLEVATION OF SEPTIC TANK
l

X1 X MAIN BAR @5" C/C


l/2

inlet pipe 4" dia outlet pipe 4" dia

l= LONG SPAN
L= SHORT SPAN
l/4

Plan
SEPTIC TANK
DETAILS OF ROOF SLAB
Applicant's Signature
25'-8"
1' 23'-8" 1'

1'
1'
1'-0" REAR SET BACK

1'-6" AVR. RIGHT SET BACK


1'-0" LEFT SET BACK

PROPOSED SITE Engineer's Signature Direction

41'-10"
38'
38'
42'

2'-10"
3'

2'-10" FRONT SET BACK

1' 23'-8" 2'


26'-8"
R O A D 8'-0'' W I D E
Approved By Architect
SITE PLAN

AREA CALCULATION
Total Plot Area = 1097.00 Sft.
G. Floor Area = 899.00 Sft.
F. Floor Area = 899.00 Sft.
S. Floor Area = 899.00 Sft.
T. Floor Area = 899.00 Sft.
Total Floor Area = 3596.00 Sft.
Building Height = 42'-6"