Minera Barrick Miskichilca Lagunas Norte
Minera Barrick Miskichilca Lagunas Norte
Reverse Osmosis System Analysis for FILMTEC™ Membranes ROSA 9.1 ConfigDB u399339_282
Project: MBM LN Case: 1
Antenor Torres, AQA 11/25/2014
Case-specific:
System Details
Feed Flow to Stage 1 198.75 m³/h Pass 1 Permeate Flow 158.99 m³/h Osmotic Pressure:
Raw Water Flow to System 198.75 m³/h Pass 1 Recovery 79.99 % Feed 1.32 bar
Feed Pressure 21.61 bar Feed Temperature 12.0 C Concentrate 5.86 bar
Flow Factor 0.85 Feed TDS 3413.55 mg/l Average 3.59 bar
Chem. Dose None Number of Elements 180 Average NDP 16.21 bar
Total Active Area 6610.76 M² Average Pass 1 Flux 24.05 lmh Power 149.16 kW
Water Classification: Wastewater with DOW Ultrafiltration, SDI < 2.5 Specific Energy 0.94 kWh/m³
Feed Feed Recirc Conc Conc Perm Avg Perm Boost Perm
Stage Element #PV #Ele Flow Press Flow Flow Press Flow Flux Press Press TDS
(m³/h) (bar) (m³/h) (m³/h) (bar) (m³/h) (lmh) (bar) (bar) (mg/l)
1 BW30-400 18 6 198.75 21.27 0.00 89.70 19.41 109.05 27.17 1.00 0.00 30.50
2 BW30-400 8 6 89.70 19.06 0.00 51.87 16.94 37.83 21.21 1.00 0.00 69.56
3 BW30-365 4 6 51.87 16.60 0.00 39.76 14.56 12.11 14.88 1.00 0.00 131.72
Pass Streams
(mg/l as Ion)
Concentrate Permeate
Name Feed Adjusted Feed
Stage 1 Stage 2 Stage 3 Stage 1 Stage 2 Stage 3 Total
NH4+ + NH3 51.34 55.00 120.42 198.77 253.01 7.86 12.99 20.65 10.05
K 17.60 17.60 37.93 64.05 82.29 0.88 2.10 4.18 1.42
Na 510.50 510.53 1127.94 1945.92 2534.70 2.65 6.33 12.60 4.28
Mg 3.10 3.10 6.86 11.86 15.46 0.00 0.01 0.02 0.01
Ca 469.00 469.00 1038.28 1794.26 2339.67 0.70 1.68 3.37 1.14
Sr 0.91 0.91 2.01 3.48 4.54 0.00 0.00 0.01 0.00
Ba 0.03 0.03 0.07 0.11 0.15 0.00 0.00 0.00 0.00
CO3 4.29 4.29 10.77 20.32 27.77 0.00 0.00 0.00 0.00
HCO3 100.00 100.00 217.67 370.86 479.46 1.51 3.19 5.97 2.25
NO3 150.00 150.00 316.86 527.08 671.44 12.74 28.61 53.06 19.59
Cl 187.09 187.09 411.88 708.52 921.24 2.18 5.14 10.02 3.48
F 1.00 1.00 2.21 3.80 4.95 0.01 0.02 0.03 0.01
SO4 1913.00 1913.00 4231.71 7308.26 9526.20 5.62 13.13 25.44 8.92
SiO2 1.94 1.94 4.29 7.41 9.66 0.01 0.02 0.03 0.01
Boron 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
CO2 0.36 0.36 0.93 1.91 2.78 0.35 1.06 1.99 0.64
TDS 3409.86 3413.55 7525.29 12961.08 16866.91 30.50 69.56 131.72 47.51
pH 8.52 8.52 8.37 8.21 8.13 6.93 6.76 6.74 6.83
*Permeate Flux reported by ROSA is calculated based on ACTIVE membrane area. DISCLAIMER: NO WARRANTY, EXPRESSED OR IMPLIED, AND NO
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS GIVEN. Neither FilmTec Corporation nor The Dow Chemical
Company assume any obligation or liability for results obtained or damages incurred from the application of this information. Because use conditions and applicable
laws may differ from one location to another and may change with time, customer is responsible for determining whether products are appropriate for customer’s
use. FilmTec Corporation and The Dow Chemical Company assume no liability, if, as a result of customer's use of the ROSA membrane design software, the
customer should be sued for alleged infringement of any patent not owned or controlled by the FilmTec Corporation nor The Dow Chemical Company.
file:///C:/Program%20Files%20(x86)/Dow%20Chemical/ROSA9/MyProjects/MBM%20... 27/11/2014
ROSA Detailed Report Página 2 de 3
Reverse Osmosis System Analysis for FILMTEC™ Membranes ROSA 9.1 ConfigDB u399339_282
Project: MBM LN Case: 1
Antenor Torres, AQA 11/25/2014
Design Warnings
WARNING: Maximum recommended element permeate flow rate has been exceeded. Please change your system design to reduce the element
permeate flows. (Product: BW30-400, Limit: 1.07m³/h)
WARNING: Maximum element recovery has been exceeded. Please change your system design to reduce the element recoveries. (Product:
BW30-400, Limit: 14.00%)
WARNING: The feed flow rate is greater than the recommended maximum feed flow. Please change your system design to reduce feed flow
rates. (Product: BW30-365, Limit: 11.81m³/h)
Solubility Warnings
Stage Details
Perm Flow Perm TDS Feed Flow Feed TDS Feed Press
Stage 1 Element Recovery
(m³/h) (mg/l) (m³/h) (mg/l) (bar)
1 0.10 1.09 20.07 11.04 3413.55 21.27
2 0.11 1.06 23.19 9.96 3783.91 20.81
3 0.12 1.02 27.00 8.90 4229.71 20.42
4 0.13 1.00 31.74 7.87 4776.62 20.09
5 0.14 0.96 37.81 6.88 5462.91 19.81
6 0.16 0.93 45.90 5.91 6347.84 19.59
Perm Flow Perm TDS Feed Flow Feed TDS Feed Press
Stage 2 Element Recovery
(m³/h) (mg/l) (m³/h) (mg/l) (bar)
1 0.08 0.89 50.54 11.21 7525.29 19.06
2 0.08 0.85 56.93 10.32 8171.83 18.59
3 0.09 0.81 64.44 9.47 8902.04 18.17
4 0.09 0.77 73.32 8.66 9729.48 17.80
5 0.09 0.73 83.97 7.89 10670.20 17.47
6 0.09 0.68 96.87 7.16 11741.45 17.19
Perm Flow Perm TDS Feed Flow Feed TDS Feed Press
Stage 3 Element Recovery
(m³/h) (mg/l) (m³/h) (mg/l) (bar)
1 0.04 0.58 106.64 12.97 12961.08 16.60
2 0.04 0.55 116.20 12.39 13562.58 16.20
3 0.04 0.52 126.64 11.84 14185.09 15.82
4 0.04 0.49 138.03 11.32 14827.83 15.48
5 0.04 0.46 150.46 10.83 15489.83 15.15
6 0.04 0.43 163.98 10.37 16169.95 14.84
Permeate Flux reported by ROSA is calculated based on ACTIVE membrane area. DISCLAIMER: NO WARRANTY, EXPRESSED OR IMPLIED, AND NO
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS GIVEN. Neither FilmTec Corporation nor The Dow Chemical
Company assume any obligation or liability for results obtained or damages incurred from the application of this information. Because use conditions and applicable
laws may differ from one location to another and may change with time, customer is responsible for determining whether products are appropriate for customer’s
use. FilmTec Corporation and The Dow Chemical Company assume no liability, if, as a result of customer's use of the ROSA membrane design software, the
customer should be sued for alleged infringement of any patent not owned or controlled by the FilmTec Corporation nor The Dow Chemical Company.
file:///C:/Program%20Files%20(x86)/Dow%20Chemical/ROSA9/MyProjects/MBM%20... 27/11/2014
ROSA Detailed Report Página 3 de 3
Scaling Calculations
file:///C:/Program%20Files%20(x86)/Dow%20Chemical/ROSA9/MyProjects/MBM%20... 27/11/2014