Fermator 4+
Fermator 4+
ASSEMBLING INSTRUCTIONS
AND REGULATION
OF CABIN DOORS
VVVF-4+ MODULE
PROGRAMMING ................................................................................................................10
INPUTS ............................................................................................................................11
PROGRAMMING EXAMPLES ..............................................................................................14
CHARACTERISTICS PAGE ..................................................................................................15
2 CABIN DOORS
AUTOMATIC DOORS FOR LIFTS PARTS DESCRIPTION
1 - Fixation bracket
2 - Operator
3 - Plate
4 - Panels
2
5 - Tread
3 6 - Tread support
7 - Toe guard
4
Side Cabin Door
1
2
5 6
7 3
7 6
CABIN DOORS 3
AUTOMATIC DOORS FOR LIFTS SITUATION OF THE OPERATOR IN THE CABIN
0
22
fig. 1
HL
fig. 2
HL + 220
fig. 3
4 CABIN DOORS
ADJUSTMENT OF CO.
AUTOMATIC DOORS FOR LIFTS IN CENTRE PARTING DOORS
Slow plates:
Fast plates:
X*
fig. 2 =
* X = Distance between plates when the door is Adjust the opening of the door by the
closed + CO + 15mm. (formula for operators with slots of the top of the hanger plates.
automatic landing doors).
fig. 1
* X = Distance between plates when the door is
closed + CO (formula for semiautomatic landing
doors).
ADJUSTMENT OF CO. IN SIDE OPENING DOORS
fig. 1
fig. 2
CABIN DOORS 5
AUTOMATIC DOORS FOR LIFTS INSTALATION OF GUIDE SHOES AND HANGERS
Guide shoes (fig. 1) and hangers (fig. 2) installation in panel
procedure.
Plate
Track
Guide Shoe
Hanger
Tread
Panel
Panel
ADJUSTMENT OF PANELS
The following procedure is the same for any type of cabin door (Central
or side opening).
INCORRECT
6 CABIN DOORS
AUTOMATIC DOORS FOR LIFTS ADJUSTMENT OF WHEELS
1º The adjustment will be made by the inferior wheels (eccentric), rotating the shaft we can adjust the
force done to the track.
2º This adjustment may be done with an allen wrench of 5 mm. and the flat key. An excessive tightening
could stop the panel.
Detail fig. 1
Concentric
Eccentricity: 2’5mm.
Eccentric
CABIN DOORS 7
CORRECT ADJUSTMENT
AUTOMATIC DOORS FOR LIFTS BETWEEN CLAMP AND RETAINER
Once the skate is placed (145mm. between the end of the plate and the shaft of the skate), in locked
position, adjust the clamp-retainer set by the slots (8 x 25) of the support with a gap of 0’5 mm. in the
horizontal and vertical shaft.
CENTRAL CABIN
DOOR
* *
ELEMENTS SITUATION
20 (B)
10 (C)
20 (A) 30
HL +210
HL +225
HL +80
30 (D) 30 (D)
8 CABIN DOORS
AUTOMATIC DOORS FOR LIFTS LOOKING DEVICE
Central parting
doors looking device
Side opening
doors looking device
A1
A2
B2
CABIN DOORS 9
AUTOMATIC DOORS FOR LIFTS
TECHNICAL MANUAL
AND ELECTRONICAL
MODULE
REGULATION VVVF-4+
10 CABIN DOORS
AUTOMATIC DOORS FOR LIFTS PROGRAMMING
DESCRIPTION OF SWITCHES
The unit may be programmed using the DIL switches on the front of the unit. If 1 2 3 4
any change is made to any of the above switch selections, the Mains Supply to the O
N
VVVF-4+ unit MUST be switched OFF and ON again to read the new programming. O
F
The switches functions are: F
• 1.- 1 & 2 Inputs.
ON: 1 Input.
The door control unit will be controlled by a single input. Any voltage between 12 to 250 volts
AC or DC applied between terminals 8 & 10 will close the doors. Without input active the door
opens. Open input is not used.
OFF: 2 Inputs.
The door control module will be controlled by two independent inputs. Any voltage between
12 to 250 volts AC or DC applied between terminals 8 & 10 will cause the doors to close. And
between terminals 12 & 10 will cause the doors to open. In the absence of a signal, the doors
will remain static. If both inputs are applied then the open signal has priority.
1 Inputs: 2 Inputs:
CABIN DOORS 11
AUTOMATIC DOORS FOR LIFTS INPUTS
12 CABIN DOORS
AUTOMATIC DOORS FOR LIFTS INPUTS
FLOOR LEVEL 26
RE-OPEN 21
SLOW CLOSE 25
+ 12 V COM 23
Fig. 8. Connection of the «other inputs». (26, 21, 25, 23).
• 21. Reopening.
This signal is for installing the cabin door swich or an external barrier. This signal has
priority to the closing signal. Use contacts free on tension. For activating close one contact
with the main supply +12V. (23).
• 23. + 12 V. COM
This terminal is used for giving with an isolated contact a reopening order or a slow
closing.
Always use contacts free of tension and usually open.
CABIN DOORS 13
AUTOMATIC DOORS FOR LIFTS INPUTS
OUTPUT RELAYS AND LED INDICATORS (from 30 to 41)
Output relays have been provided to give continuous information to the main lift controller concerning
the status of the doors. One 2 Amp 150 Volts volt free change over contact is provided on each relay that
may be used by the main lift controller to pilot such information as «doors fully opened», «doors fully
closed», «Photoelectric detection», «obstruction in the doorway» and «door control O.K.».
• Opened. 30.
Led indicator and relay activated when the doors 31.
OPENED
32.
are fully open.
• Closed.
33.
Led indicator and relay activated when the doors 34.
are fully closed and locked. CLOSED
35.
• Photocell.
Led indicator and relay activated when the
photocell or the reopening input is operated.
PHOTOCELL
• Obstruction.
Led indicator and relay activated when an
obstacle is detected that stops the doors from
closing. The signal will reset when the doors reach
the opened or closed position. OBSTRUCTION
• Status.
Blinking led indicating proper working conditions.
14 CABIN DOORS
AUTOMATIC DOORS FOR LIFTS INPUTS
ON / OFF SWITCH (57)
Disconnects the unit from the 230 Volts AC mains supply.
Caution: When the supply is switched off, capacitors in the control system will remain charged for
a short time. Allow 60 seconds before handling the Control Card or Motor.
PROGRAMMING EXAMPLES
MASTER: 1 INPUT
• Configuration
1 2 3 4 1. ON: 1 Input.
O
2. Depends on type of door.
N 3. Depends on type of door.
O
F 4. ON: Master.
F
• Inputs
1. (8) Close. Closes the doors with voltage between terminals 8
& 10. Open the doors when the voltage between
terminals 8 & 10 is removed.
2. (17...20) Photocell. Doors will reopen if the photocell beam is
broken.
3. (21-23) Reopening. Doors will not close if this signal is active.
4. Obstacle. Door will open if an obstacle is detected by the
motor ceasing to rotate.
5. (25-23) Slow Closing. Closes regardless of the state of the photocell.
• Priorities
1.(21-23) Reopening.
2. Obstacle.
3.(25-23) Slow Closing.
4.(17...20) Photocell.
5.(8) Close.
SLAVE: 2 INPUTS
• Configuration
1. OFF: 2 Inputs.
1 2 3 4 2. Depends on type door.
O 3. Depends on type door.
N
O 4. OFF: Eslave.
F
F • Inputs
1. (8) Close. Closes the doors with voltage between terminals
8 & 10.
2. (12) Open. Open the doors with voltage between terminals
12 & 10. Pryority to close.
3. (17...20) Photocell. Does not re-open the doors when activated
but provides signal to main controller via the
Photocell relay.
4. (21-23) Reopening. Doors will not close if this signal is active
5. Obstacle. Doors will not re-open if an obstacle is detected
by the motor ceasing to rotate.
6. (25-23) Slow Closing. Closes regardless of the state of the photocell.
• Priorities
1. (12) Open.
2. (21-23) Reopening.
3. (25-23) Slow Closing.
4. (8) Close.
CABIN DOORS 15
AUTOMATIC DOORS FOR LIFTS CHARACTERISTICS PAGE
POWER SUPPLY:
• AC voltage range: 230v +10%, -15%. AC/DC
• Frequency supply: 50...60 Hz.
• Minimum supply: 70 mA, 13W.
• Open door power: 0,6 A 80W.
• Nominal power: 0,93 A 140W.
• Maximum power: 1,38 A 190W.
INVERTER:
• Carrier frequency: 16 KHz.
• Frequency range: 0,5...100 Hz.
• Voltage range: 40...200 V AC III
• Maximum output current: 4A
• Positional control: Quadrature encoder.
MOTOR:
• Asynchronous three phase: 6 poles.
• Voltage supply: 250 V.
• Power: 250 W.
• Thermic class: B-130°C.
• Nominal speed: 900 RPM.
INPUTS:
• Impedance: 20 KΩ.
• Voltage: 12...230 V AC / DC.
OUTPUTS:
• Contacts: Switched.
• R. contact: 50 mW.
• Swich time: 5 ms.
• Output current: Máximum: 5A
• Voltage: 250 V
PERFORMANCE:
• Open Speed: 200...1000 mm/s.
• Close speed: 150...600 mm/s.
• Maximum acceleration: 800...1500 mm/s.
• Safety force: 40...150 N adjustable.
• Maintenance torque (Opened Door): 80 N/ cm.
16 CABIN DOORS
AUTOMATIC DOORS FOR LIFTS
EMERGENCY
SUPPLIER*
CHARACTERISTICS:
1 - Control by microprocessor.
2 - Verification of the battery charge level.
3 - Output power Until 1.5 A / 110 Volts .
4 - Complete control of the rescue process.
CABIN DOORS 17
AUTOMATIC DOORS FOR LIFTS OPERATION
This equipment has a “bypass” relay that switches the supply for the VVVF control from the mains
supply or from the internal converter if there is a mains power failure.
INSTALLATION
1 - It will be installed close to the VVVF, connected in the input side of the VVVF.
2 - The input supply to the VVVF will be connected to OUTPUT terminals 5/6/7 of the emergency
supplier instead of being directly connected to the mains supply.
3 - The emergency supplier should be connected to a 230V AC mains supply on terminals 1/2/3 marked
as SUPPLY 230V AC.
4 - A 12V rechargeable battery should be connected to terminals 28/29 marked BATTERY, special care
should be given to the polarity (+29 and 28- ) when connecting.
5 - To enable the doors to open correctly when on emergency supply a volt free contact should be
provided to the VVVF box on terminals 66 and 67. This contact should be normally closed only at
floor level and can be operational on normal and when on emergency supply. As this input is only
operational during the mains power failure, no synchronization with the mains supply is needed.
6 - The contacts 23(+12V) and the 6 (GND) in the emergency supplier have to be connected to the
output terminals 23(+12V COM) and 6(GND) respectively in the VVVF.
7 - The terminal 26 (FLOOR) of the emergency supplier has to be connected to the terminal 26 input
in the VVVF4+ (FLOOR) to inform it about the mains supply status.
If the polarity is reversed the 20 A fuse will blow and damage to the electronic board
could occur. The battery should have a minimum capacity of 2 Ah.
Special care has to be taken with the cable and battery connector. The wire connecting
the battery to the terminals 28/29 must be as short as possible and terminated
properly, because the current can reach a peak level of 15A.
18 CABIN DOORS
AUTOMATIC DOORS FOR LIFTS LED STATUS
Once the system is installed, the ON led shows the system status:
1 - Always ON: means that the battery is not charged. The charge process of the battery can last about
48 hours, so after this time the Normal status should be achieved. If not, the battery is drained
and not functioning.
2 - Blinking: means Normal status. The system is Ok and the battery is charged.
3 - Blinking every 15s: means that there is no 230V AC mains supply and the unit is waiting for the
Floor signal to commence the “emergency open” process.
BATTERY CONTROL
As long as the emergency supplier is connected to the mains supply and with a battery connected,
it charges the battery until 100% charge is achieved. When the charge level is lower than 70%, the
charge process starts again.
If there is a mains power failure, the system waits for the Floor signal to open the door. This open cycle
lasts for a fixed time after which the system starts a low power status waiting for the mains supply to
be reinstated.
SCHEME
VVVF Mains
Circuit Emergency Supplier Supply
5 7 1 1
MOTOR ALIMENTACION
230V AC
N 6 6 L1' L2 2 2
56.U MOTOR MAINS SUPPLY GND 7 5 GND GND 3 3
56.V MOTOR F L2' L1
Rellano / Floor
56.W MOTOR 12 23 CON3
ENTRADAS ABRIR/OPEN 11 26 +12V COM 66
INPUTS 0 Volt 10 PISO / FLOOR RELLANO PISO 67
COM 9 FLOOR
ENCODER +12V ON
55.1 GND CERRAR/CLOSE
8
BAT+
29
55.2 BAT 28
FASE1 BAT- BT1
55.3 ENTRADAS PRIORITARIAS
FASE2 26 2 1
55.4 PRIORITY PISO/FLOOR
21
+12V INPUTS REOPEN 25
SLOWCLOSE
+12V COM
23 Bateria
20
12V. 2Ah
FOTOCELULA REC 19
PHOTOCELL GND 18
GND 17
EMI
PUERTO SERIE 16
V- RX
SERIAL PORT RX 14
TX 13
V+
CABIN DOORS 19
ATENTION: Any type of modification not reflexed in this manual, before testing it should be notified
to our Technical Department.
TECNOLAMA declines all responsability in the case of damages produced in the operator and
installation, if the instructions given have not been followed.
TECNOLAMA reserves the rights to modify the products specifi cations of this technical brochure
without any previous advise.
DECLARATION OF CONFORMITY
Tecnolama, S.A.
Ctra. Constantí Km. 3
43206 REUS (España)
Herewith declares that the products mentioned below conform with the following E.U.
council directives:
Ctra. Constantí, Km 3 - 43206 REUS (Spain) - Tel. +34 977 774 065 - Fax +34 977 771 615
http://www.fermator.com e-mail:[email protected]