0% found this document useful (0 votes)
17 views

Pro Gauge

The document discusses an automatic tank gauging system called ProGauge. It includes details about the system's components like probes, consoles and options. The document provides information on why automatic tank gauging is needed and the benefits it provides.

Uploaded by

Aliou Souane
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views

Pro Gauge

The document discusses an automatic tank gauging system called ProGauge. It includes details about the system's components like probes, consoles and options. The document provides information on why automatic tank gauging is needed and the benefits it provides.

Uploaded by

Aliou Souane
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

ProGauge Automatic Tank Gauging

System
Tokheim ProGauge Electronics Systems
❖ Service Stations
Maglink Consoles
Range of consoles with
Wired and wireless
Black Seal capabilities
Magnetostrictive
probes

Wired & Wireless tank probes


Intrinsecally safe version battery
operated ( Wireless)

MAGLINK CONSOLES
Filling stations and fueldepots
management
2
Why ATG Needed?
➢ Inventory Monitoring

➢ Delivery Accounting & re-ordering visibility

➢ Product Quality

➢ Environment protection – Leak detection

➢ Operator’s safety

➢ Losses Accountability

➢ Compliance

3
PROGAUGE CONSOLES Tank Level Alarms

4
MAGNETOSTRICTIVE PROBES - Make the smart move
XMT-SI-RS485
Wired probe.

Standard features
➢ Magnetostrictive technology
➢ Stainless steel enclosure Ø 50 mm
➢ Supports diagnostic and maintenance functions
➢ Single float monitors both petrol, Diesel and other petroleum products( Viscosity & Density range)
➢ Remote configuration of operation parameters
➢ RS485
➢ Standard measuring range from1000 - 3,500mm and customised up to 6000mm
➢ Product accuracy: +/- 0.5mm, Water accuracy: +/- 0.5mm
➢ Temperature accuracy range -20 +70°C: +/- 0.2°C
➢ Up to max. 5 integrated digital temperature sensors
➢ Smart probe can be connected with multi drop facility

5
Density Probes – Highly Accurate
Features:
➢ Electronics based on a Microprocessor
➢ Stainless steel and composite caps case, IP68.
➢ Remote configuration of operation parameters, supports diagnostics and maintenance
function
➢ RS485 serial port
➢ Standard measuring range from1000 - 3,500mm and customised up to 6000mm
➢ Data transmitted:
o Product level in 0.01 mm
o Water level in 0.01 mm
o Medium temperature detected through digital temperature sensor placed along the probe shaft (max
5)
o Density range (option): 600-900 Kg/m3
o Density Accuracy (option): 5 Kg/m3
o Measurement accuracy: < 0.2 mm.
o Measurement resolution: +/- 0,01 mm. (+/- 0.0001 mm for EPA option)
o Measurement repeatability: +/- 0,05 mm.
o Temperature accuracy: +/- 0,2°C (up to 5 temperature sensor option is available for static leak test)
o Temperature resolution: 0.0625°C (0.0001°C for EPA option)

6
MagLink L X With advance technology
Main Features
➢ Web access and WI-FI connection
➢ IFSF compliance
➢ Colour resistive touch-screen TFT 7” display
➢ Manages up to 32 tanks
➢ Event recording up to 32 Gb with removable micro-SD card
➢ Safe and easy programming via web based interface
➢ Tank strapping table stored in NV RAM up to 500 points
Technical characteristics ➢ Leak detection, automatic reconciliation, deliveries, trends, historical events / alarms
recording Inches/Gallons option
•Microprocessor
•Power Supply 230 Vac - Real Time Clock ➢ Integrated communication protocols including: Tokheim, Gilbarco, Dresser Wayne,
•GSM/GPRS, Radio wireless Retalix, Orpak, DOMS
•No 04 low power programmable relays ➢ Full color graphical display showing:
•No 06 digital /analogy inputs - Product level in m m
•RS485 - RS232 - Real volume and compensated at 15 °C in litres
•Ethernet port - Interface measure in m m (water detection)
•USB device - Product mean temperature
•Can-bus port - Volume of empty portion of tank in litres (Ullage)
•Active or passive integrated Intrinsically - Fuel Quality sensor (Density, Viscosity, Dielectric)
safe barriers - Alarm signals, unit of measure
•Synthetic resin enclosure IP40 protection

7
MAGLINK LX Inventory Details