Bill of Quantities Part-1 For Egp
Bill of Quantities Part-1 For Egp
Bill of Quantities
Bill of Quantities
Total
Unit Price Unit Price Total Price
Item Price
Item Measurement
Group Code (if Description of Item Quantity
no. Unit In figures In Words In Figures
any) In Words
(BDT) (BDT) (BDT)
(BDT)
Five Five
PART-A-i : SITE
Hundred Thousand
2 DEVELOPMENT 1.2 b) By dredging including necessary systems thereof. Cum 10.000 500.001 5000.010
point Zero point Zero
WORKS
Zero One One
One Crore
Eleven
Mechanical compaction of earth beyond plinth area, required
One Lakh
for pre-approved specific engineering purpose in 150 mm
Hundred Sixty-
layers including levelling, watering and consolidation each
PART-A-i : SITE and Seven
layer with chain dozer, grader, roller etc. to achieve minimum
3 DEVELOPMENT 2 Cum 56400.000 198.001 Ninety- 11167256.400 Thousand
dry density of 95% with optimum moisture content (modified
WORKS Eight point Two
proctor test) up to finished level all complete and accepted by
Zero Zero Hundred
the engineer-in-charge subjected to submission of the
One and Fifty-
method statement.
Six point
Four
Six Lakh
''Earthwork in excavation of pond of any dimension in all
Fifty-Five
PART-A-ii : SITE kinds of soil including cutting up to required depth including
Two Thousand
DEVELOPMENT bailing out water and throwing on the embankment, breaking
Hundred Two
WORKS ( clods, ramming and leveling, dressing in 225 mm layer with
5 2.a Cum 2730.000 240.001 and Forty 655202.730 Hundred
EARTHWORK IN maintaining the side slopes and level of both pond and the
point Zero and Two
EXCAVATION OF embankment as per design and accepted by the Engineer-in-
Zero One point
POND) charge.
Seven
a) For initial lead of 30 m and lift of 1.5 m''
Three
One Lakh
PART-A-ii : SITE
Two Thirty
DEVELOPMENT
Hundred Thousand
WORKS ( b) Added for each additional lift of 0.3 m beyond 1.5 m and
6 2.b Cum 545.000 240.001 and Forty 130800.545 Eight
EARTHWORK IN up to 3 m (Depth of 1.8 m)
point Zero Hundred
EXCAVATION OF
Zero One point Five
POND)
Four Five
One Lakh
PART-A-ii : SITE
Two Thirty
DEVELOPMENT
Hundred Thousand
WORKS ( c) Added for each additional lift of 0.3 m beyond 1.5 m and
7 2.c Cum 545.000 240.001 and Forty 130800.545 Eight
EARTHWORK IN up to 3 m (Depth of 2.1 m)
point Zero Hundred
EXCAVATION OF
Zero One point Five
POND)
Four Five
One Lakh
PART-A-ii : SITE Thirty-Six
Two
DEVELOPMENT Thousand
Hundred
WORKS ( d) Added for each additional lift of 0.3 m beyond 1.5 m and Two
8 2.d Cum 545.000 250.001 and Fifty 136250.545
EARTHWORK IN up to 3 m (Depth of 2.4 m) Hundred
point Zero
EXCAVATION OF and Fifty
Zero One
POND) point Five
Four Five
One Lakh
PART-A-ii : SITE
Two Fifty-Two
DEVELOPMENT
Hundred Thousand
WORKS ( e) Added for each additional lift of 0.3 m beyond 1.5 m and
9 2.e Cum 545.000 280.001 and Eighty 152600.545 Six
EARTHWORK IN up to 3 m (Depth of 2.7 m)
point Zero Hundred
EXCAVATION OF
Zero One point Five
POND)
Four Five
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 1/80
3/11/24, 2:55 PM View Form
One Lakh
PART-A-ii : SITE
Two Fifty-Two
DEVELOPMENT
Hundred Thousand
WORKS ( f) Added for each additional lift of 0.3 m beyond 1.5 m and up
10 2.f Cum 545.000 280.001 and Eighty 152600.545 Six
EARTHWORK IN to 3 m (Depth of 3.0 m)
point Zero Hundred
EXCAVATION OF
Zero One point Five
POND)
Four Five
One Lakh
PART-A-ii : SITE Sixty-
DEVELOPMENT Three Three
WORKS ( h) Added for each additional lift of 0.3 m beyond 3 m and up Hundred Thousand
12 2.h Cum 545.000 300.001 163500.545
EARTHWORK IN to 4.5 m (Depth of 3.6 m) point Zero Five
EXCAVATION OF Zero One Hundred
POND) point Five
Four Five
Two Lakh
Forty-Four
PART-A-ii : SITE
Cleaning and disposing of excavated earth from the Seven Thousand
DEVELOPMENT
construction site by truck or by any other means to a place Hundred Five
WORKS (
14 3 within 30 km radius of the city or town area including loading Cum 335.000 730.001 and Thirty 244550.335 Hundred
EARTHWORK IN
& unloading at both ends, leveling and dressing the carried point Zero and Fifty
EXCAVATION OF
earth etc. complete and accepted by the Engineer-in-charge. Zero One point
POND)
Three
Three Five
Twelve
Earth filling in foundation/ side slope trenches and plinth in
PART-A-ii : SITE Lakh
150 mm layer with earth available within 90 m of the building
DEVELOPMENT Two Sixty-Eight
site to achive minimum dry density of 95% with optimum
WORKS ( Hundred Thousand
15 4 moisture content (Modified proctor test) including carrying Cum 6340.000 200.001 1268006.340
EARTHWORK IN point Zero AND Six
watering, leveling, dressing and compacting to a specified
EXCAVATION OF Zero One point
percentage Each layer up to finished level etc. all complete
POND) Three
and accepted by Engineer-in-charge.
Four
Four Four
PART-A-ii : SITE
Hundred Thousand
DEVELOPMENT Bailing out water by 1 cusec electricity operated pump
and Seven
WORKS ( including hire charge of pump, fuel, operator, spares and
16 5 Per Hour 10.000 474.001 Seventy- 4740.010 Hundred
EARTHWORK IN maintenance etc. all complete and accepted by the Engineer-
Four point and Forty
EXCAVATION OF in-charge.
Zero Zero point Zero
POND)
One One
One Lakh
Sixty-Four
One
Thousand
PART-B-i : Hundred
Earthwork in excavation in foundation trenches up to 1.5 m Eight
20 BOUNDARY WALL 3.b cum 1030.000 160.001 and Sixty 164801.030
depth and maximum 10 m lead Hundred
( CIVIL WORKS) point Zero
and One
Zero One
point Zero
Three
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 2/80
3/11/24, 2:55 PM View Form
One Lakh
Four Twenty-
Hundred Two
PART-B-i :
Bailing out of trapped water caused by inundation or rain, by and Thousand
21 BOUNDARY WALL 4 hour 260.000 470.001 122200.260
pump from foundation trenches. Seventy Two
( CIVIL WORKS)
point Zero Hundred
Zero One point Two
Six
Fifteen
Thousand
Supplying and laying of single layer polythene sheet
PART-B-i : Forty point Two
weighing one kilogram per 6.5 square meter in floor or any
23 BOUNDARY WALL 6 Sqm 380.000 40.001 Zero Zero 15200.380 Hundred
where below cement concrete complete in all respect and
( CIVIL WORKS) One point
accepted by Engineer-in-charge.
Three
Eight
Brick works with first class bricks with cement sand (F.M. 1.2) Forty-Six
mortar (1:4) in exterior walls including filling the interstices Lakh
Ten
with mortar, raking out joints, cleaning and socking the bricks Sixty-Four
Thousand
at least for 24 hours before use and washing of sand, Thousand
PART-B-i : AND
necessary scaffolding, curing at least for 7 days etc. all Eight
25 BOUNDARY WALL 8 cum 462.000 10097.001 Ninety- 4664814.462
complete including cost of water, electricity and other Hundred
( CIVIL WORKS) Seven
charges (measurement to given as 250 mm width for one and
point Zero
brick length and 375 mm for one brick and a half brick length) Fourteen
Zero One
accepted by the Engineer-in-charge. (Cement: CEM-II/B-M) point Four
i) Ground floor Six Two
''125 mm brick works with first class bricks with cement sand
(F.M. 1.2) mortar (1:4) and making bond with connected walls One
Fourteen
including necessary scaffolding, raking out joints, cleaning Thousand
Thousand
PART-B-i : and soaking the bricks for at least 24 hours before use and Four
AND
26 BOUNDARY WALL 9 washing of sand, curing at least for 7 days in all floors Sqm 10.000 1408.001 Hundred 14080.010
Eighty
( CIVIL WORKS) including cost of water, electricity and other charges etc. all and Eight
point Zero
complete and accepted by the Engineer-in-charge. (Cement: point Zero
One
CEM-II/B-M) Zero One
i) Ground floor''
Cost of bed preparation including one layer brick flat soling Ninety-
with first class/picked jhama bricks including preparation of Eight
bed and filling the interstices with local sand, leveling etc. Three Thousand
complete and accepted by the Engineer-in-charge, Minimum Hundred One
PART-B-i : 12 mm thick cement sand (F.M. 1.2) plaster with neat cement and Hundred
28 BOUNDARY WALL 11 finishing with cement (1:4) including washing of sand, Sqm 303.000 324.001 Twenty- 98172.303 and
( CIVIL WORKS) finishing the edges and corners and curing at least for 7 Four point Seventy-
days, cost of water, electricity, scaffolding and other charges Zero Zero Two point
etc. all complete in all respect and accepted by the Engineer- One Three
in-charge (Cement: CEM-II/B-M) and polythene as separator Zero
between pile layers during casting concrete Three
Four Lakh
Centering and shuttering, including strutting, propping etc.
Twenty-
(The formwork must be rigid enough both in and out of plane,
Four Seven
to make the concrete surface true to the designed shape and
PART-B-i : Hundred Thousand
size by using necessary MS sheets of minimum 18 BWG,
29 BOUNDARY WALL 12 Sqm 1045.000 409.001 and Nine 427406.045 Four
angles of minimum size 1.5 x 1.5 x 3/16'' for sides,angles of
( CIVIL WORKS) point Zero Hundred
minimum size 1 x 1 x 3/16'' for frames , 1.5'' x 3/16'' flat bars
Zero One and Six
etc.) and removal of form for precast pile (The formwork is
point Zero
considered for two sides and front shuttering of the pile)
Four Five
30 PART-B-i : 13 Pre-cast pile shoe making & supplying pre-fabricated frustum Each 346.000 3326.001 Three 1150796.346 Eleven
BOUNDARY WALL of square cone having four sides and a toe made of 6 mm Thousand Lakh Fifty
( CIVIL WORKS) thick ASTM A36 complied MS steel plate jointed by line Three Thousand
welding, 4 nos 12 mm dia deformed MS bar jointed by line Hundred Seven
welding with MS plate along the four edges of shoe aligning and Hundred
the corner main bar of the pile and 1-12mm dia bar to fix with Twenty- and
and perpendicular to shoe toe plate aligning centre of pile, Six point Ninety-Six
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 3/80
3/11/24, 2:55 PM View Form
including cutting, shaping, sizing of MS plate and bar, all Zero Zero point
complete as per design & drawing and accepted by the One Three
Engineer-in-charge. Four Six
Thirty-
Three
Driving 300 mm x 300 mm & 350 mm x 350 mm size pre-cast
Lakh Eight
pile by rig fitted with automatic diesel operated hammer. Nine
Thousand
Before commencing driving operation by rig fitted with Hundred
PART-B-i : Six
automatic diesel operated hammer, contractor shall submit and
32 BOUNDARY WALL 15 Meter 3620.000 914.001 3308683.620 Hundred
method statement for carrying out the operation including Fourteen
( CIVIL WORKS) and
sequence of driving to the Engineer-in-charge for approval. point Zero
Eighty-
However, engineer's approval shall not relieve the contractor Zero One
Three
of his responsibilities and obligations under contract.
point Six
Two
Three
''2) FORM WORK (Steel) Centering and shuttering, including Five
Lakh Fifty-
strutting, propping etc. (The formwork must be rigid enough Hundred
Five
PART-B-i : both in and out of plane, to make the concrete surface true to and
Thousand
35 BOUNDARY WALL 17.2.a the designed shape and size by using necessary MS sheets Sqm 610.000 582.001 Eighty- 355020.610
AND
( CIVIL WORKS) of minimum 16 BWG, angles of minimum size 40 mm x 40 Two point
Twenty
mm x 5 mm, flat bars etc.) and removal of form for: Zero Zero
point Six
a) Individual & combined footing'' One
One
Twenty-
Eighteen Nine Lakh
PART-B-i :
''Foundation Beam Thousand Sixteen
36 BOUNDARY WALL 17.1.b Cum 162.000 18000.001 2916000.162
1) Casting'' point Zero Thousand
( CIVIL WORKS)
Zero One point One
Six Two
Seven
Lakh Fifty-
Four
Four
Hundred
Thousand
PART-B-i : and
Two
37 BOUNDARY WALL 17.2.b 2) Form Work/Shuttering (steel) Sqm 1530.000 493.001 Ninety- 754291.530
Hundred
( CIVIL WORKS) Three
and
point Zero
Ninety-
Zero One
One point
Five Three
Forty-One
Lakh
Eighteen
PART-B-i : ''Pedestals, column, RCC Wall etc. Seventy-
Thousand
38 BOUNDARY WALL 17.1.c 1) Casting Cum 232.000 18000.001 4176000.232 Six
point Zero
( CIVIL WORKS) i) Gr floor'' Thousand
Zero One
point Two
Three Two
39 PART-B-i : 17.2.c ''2) Form Work/Shuttering (steel) Sqm 2695.000 522.001 Five 1406792.695 Fourteen
BOUNDARY WALL i) Gr floor'' Hundred Lakh Six
( CIVIL WORKS) and Thousand
Twenty- Seven
Two point Hundred
Zero Zero and
One Ninety-
Two point
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 4/80
3/11/24, 2:55 PM View Form
Six Nine
Five
Fifteen
Minimum 12 mm thick cement sand (F.M. 1.2) plaster with Lakh
Three
neat cement finishing to plinth wall with cement (1:4) up to Seventy-
Hundred
150 mm below ground level including washing of sand, Three
PART-B-i : and
finishing the edges and corners and curing at least for 7 Thousand
43 BOUNDARY WALL 21 Sqm 4130.000 381.001 Eighty- 1573534.130
days, cost of water, electricity, scaffolding and other charges Five
( CIVIL WORKS) One point
etc. all complete in all respect as per drawing and accepted Hundred
Zero Zero
by the Engineer-in-charge. (Cement: CEM-II/B-M) i) Ground and Thirty-
One
Floor Four point
One Three
Minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:4) One Lakh
Three
with fresh cement to both inner-and outer surface of wall, Thirty-Two
Hundred
PART-B-i : finishing the corner and edges including washing of sand, Thousand
and
44 BOUNDARY WALL 22 cleaning the surface, curing at least for 7 days, cost of water, Sqm 420.000 315.001 132300.420 Three
Fifteen
( CIVIL WORKS) electricity, scaffolding and other charges etc. all complete in Hundred
point Zero
all respect as per drawing and accepted by the Engineer-in- point Four
Zero One
charge. (Cement: CEM-II/B-M) i) Ground floor Two
Three
Minimum 6 mm thick cement sand (F.M. 1.2) plaster (1:4) Lakh
with fresh cement to ceiling, R.C.C. columns, beams, surface Eighty-
of stair case, sunshades, cornices, railings, drop wall, Three Eight
PART-B-i : louvers, fins and finishing the corners and edges including Hundred Thousand
45 BOUNDARY WALL 23 washing of sand, cleaning the surface, curing at least for 7 Sqm 1290.000 301.001 and One 388291.290 Two
( CIVIL WORKS) days, cost of water, electricity, scaffolding and other charges point Zero Hundred
etc. all complete in all respect as per drawing and accepted Zero One and
by the Engineer-in-charge. (Cement: CEM-II/B-M) i) Ground Ninety-
floor One point
Two Nine
Thirty-
Supply, fabrication and installation of hot rolled structural
Nine Lakh
grade steel pipe and tube of any thickness conforming to Two
PART-B-i : Sixty
ASTM A283 with a minimum yield strength of 275 MPa, Hundred
47 BOUNDARY WALL 25 Kg 19800.000 200.001 3960019.800 Thousand
including the cost of testing, application of red/grey-oxide point Zero
( CIVIL WORKS) AND
primer etc. (up to level-4) all complete as per drawing, Zero One
Nineteen
specification and direction of Engineer-in-charge.
point Eight
48 PART-B-i : 26 Supply, fabrication and installation of built-up sections i.e. Kg 1400.000 137.001 One 191801.400 One Lakh
BOUNDARY WALL columns, beams, rafters, bracings, struts etc. (up to level-4) Hundred Ninety-
( CIVIL WORKS) from steel plates conforming to ASTM A572, with a minimum and Thirty- One
yield strength of 345 MPa, including the cost of testing of Seven Thousand
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 5/80
3/11/24, 2:55 PM View Form
plates, applicaton of red/ grey-oxide primer etc. all complete point Zero Eight
as per drawing, specification and direction of Engineer-in- Zero One Hundred
charge. and One
point Four
Twenty-
Supply, fabrication and installation of hot rolled structural One Four Lakh
grade steel channel and angle in roof truss or any form of Hundred Thirty-One
PART-B-i : structure of any thickness conforming to ASTM A36 with a and Thousand
49 BOUNDARY WALL 27 minimum yield strength of 250 MPa, including the cost of Kg 18850.000 129.001 Twenty- 2431668.850 Six
( CIVIL WORKS) testing, application of red/grey-oxide primer etc. (up to level- Nine point Hundred
4) all complete as per drawing, specification and direction of Zero Zero and Sixty-
Engineer-in-charge. One Eight point
Eight Five
Three
Supply and fixing of galvanized anchor bolts of variable dia Lakh
One
for rigid frame conforming to ASTM F1554 Grade 55, Thirty-
Hundred
Galvanized to A153, Class C or equivalent with minimum Four
PART-B-i : and
yield strength of 380 MPa, manual of steel construction by Thousand
50 BOUNDARY WALL 28 Kg 1740.000 192.001 Ninety- 334081.740
American Institute of Steel Construction (AISC) etc. including AND
( CIVIL WORKS) Two point
the cost of washer & bolts, material testing etc. all complete Eighty-
Zero Zero
as per drawing, specification and direction of the Engineer-in- One point
One
charge. Seven
Four
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 6/80
3/11/24, 2:55 PM View Form
''Concealed wiring (NYY) (through PVC conduit): Concealed
conduit wiring with the following PVC insulated and sheathed
stranded cable (NYY) / XLPE insulated and PVC sheathed
stranded cable (2XY) & PVC insulated Green / Yellow bi-
colour ECC wire (BYA) through PVC conduit of reputed
manufacturer complete with fixing materials other
accessories etc. as required including mending the damages
Five
good. All electrical contacts shall be of brass / copper
Hundred
PART-B-ii : connected through connector or soldering (no twisting shall Two Lakh
and
BOUNDARY WALL be allowed) and cables shall be manufactured and tested Sixty-Four
56 3 Rm 500.000 528.001 Twenty- 264000.500
( ELECTRICAL according to IEC / BS / VDE standards along with relevant Thousand
Eight point
WORKS) BDS standard as per detailed specification mentioned in point Five
Zero Zero
Annexure-1. The work shall be carried out as per direction &
One
approval of the Engineer In Charge. Cable manufacturer(s)
must have valid type test certificate (within last seven years)
from internationally accredited laboratory (like CPRI, KEMA
etc.) accepted / approved by the Engineer In Charge.
a) 1C-4x2.5 sqmm (NYY / 2XY) with 2.5 sqmm (BYA) ECC
wire through PVC pipe of minimum inner dia 30 mm having
wall thickness of 1.9 mm.''
Two
Thirteen
PART-B-ii : Hundred
1C-2x2.5sqmm (BYM) cable with 2.5 sqmm (BYA) ECC wire Thousand
BOUNDARY WALL and Sixty-
58 4.2 through PVC pipe of minimum inner dia 25 mm having wall Rm 50.000 261.001 13050.050 AND Fifty
( ELECTRICAL One point
thickness of 1.7 mm point Zero
WORKS) Zero Zero
Five
One
Three Sixteen
PART-B-ii : Hundred Thousand
1C-2x4.0 sqmm (BYM) cable with 4 sqmm (BYA) ECC wire
BOUNDARY WALL and Thirty- Nine
59 4.3 through PVC pipe of minimum inner dia 25 mm having wall Rm 50.000 338.001 16900.050
( ELECTRICAL Eight point Hundred
thickness of 1.7 mm
WORKS) Zero Zero point Zero
One Five
Twenty-
Four
One
PART-B-ii : Hundred
1C-2x6.0 sqmm (BYM) cable with 6 sqmm (BYA) ECC wire Thousand
BOUNDARY WALL and Thirty-
60 4.4 through PVC pipe of minimum inner dia 25 mm having wall Rm 50.000 436.001 21800.050 Eight
( ELECTRICAL Six point
thickness of 1.7 mm Hundred
WORKS) Zero Zero
point Zero
One
Five
63 PART-B-ii : 7.1 ''GANG SWITCH: each 5.000 218.001 Two 1090.005 One
BOUNDARY WALL Providing & fixing 250 volts. 5 / 6 amps (minimum) concealed Hundred Thousand
( ELECTRICAL type following switch / switch socket manufactured and and AND
WORKS) tested in accordance with relevant IEC / VDE / NEMA / BS / Eighteen Ninety
JIS standards mounted on required size 18 SWG galvanized point Zero point Zero
plain sheet / PVC board (Self-extinguishing 650oC) of 76.2 Zero One Zero Five
mm (3'''') depth. All electrical contacts shall be of brass /
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 7/80
3/11/24, 2:55 PM View Form
copper.
Made in HONGKONG / MALAYSIA / SINGAPORE / S
KOREA / THAILAND
7.1) One gang switch''
Two
Five Thousand
PART-B-ii : Hundred Five
BOUNDARY WALL and Hundred
64 7.2 Three gang switch each 5.000 514.001 2570.005
( ELECTRICAL Fourteen and
WORKS) point Zero Seventy
Zero One point Zero
Zero Five
Three
Seven Thousand
PART-B-ii : Hundred Eight
BOUNDARY WALL and Sixty- Hundred
65 7.3 Four gang switch each 5.000 763.001 3815.005
( ELECTRICAL Three and
WORKS) point Zero Fifteen
Zero One point Zero
Zero Five
Three
Seven
PART-B-ii : Thousand
Hundred
BOUNDARY WALL Nine
68 9.b 16 Amps. each 5.000 780.001 and Eighty 3900.005
( ELECTRICAL Hundred
point Zero
WORKS) point Zero
Zero One
Zero Five
''TPMCCB: Providing & fixing on a prepared board 500 volt Seven Seven
grade following triple-pole molded case circuit breaker Thousand Thousand
PART-B-ii : (TPMCCB) with thermal over-current and instantaneous Four Four
BOUNDARY WALL electromagnetic short circuit release provision, manufactured Hundred Hundred
70 11 each 1.000 7466.001 7466.001
( ELECTRICAL and tested in accordance with relevant IEC / VDE / NEMA / and Sixty- and Sixty-
WORKS) BS / JIS standards. Six point Six point
TPMCCB accepted / approved by the engineer. Zero Zero Zero Zero
a) 60 Amps. (minimum 10-KA)'' One One
Two Two
''BUS - BAR: Providing and fixing 500 V 3-phase bus-bar
Thousand Thousand
system assembled in prelaid board with porcelain insulators.
PART-B-ii : Five Five
There will be equal size holes on every bar at 0.5'''' interval
BOUNDARY WALL Hundred Hundred
71 12 and bar to bar gap shall be 2'''' - 3''''. each 1.000 2544.001 2544.001
( ELECTRICAL and Forty- and Forty-
a) 60 - 100 Amps. Copper flat bar (5 nos) : 4 nos 9''''
WORKS) Four point Four point
x1''''x3mm and 1 no 4''''x1''''x4mm for earthing mounted on
Zero Zero Zero Zero
insulator at both ends individually.''
One One
''PVC PIPE :
Providing & laying of following PVC pipe (best quality PVC
PART-B-ii : pipe of reputed manufacturer) embedded in wall / column /
Fifty point Five
BOUNDARY WALL ceiling / floor etc. with all accessories, 18 SWG GP sheet pull
73 14.a Rm 100.000 50.001 Zero Zero 5000.100 Thousand
( ELECTRICAL box with 3 mm thick ebonite sheet cover, fixing materials etc.
One point One
WORKS) as required including mending the damages good.
a) Minimum inner dia 20 mm & minimum wall thickness 1.5
mm. ''
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 8/80
3/11/24, 2:55 PM View Form
One Lakh
PART-B-ii : Sixty-
Thirty-
BOUNDARY WALL b) Minimum inner dia 25 mm & minimum wall thickness 1.7 Seven
74 14.b Rm 2000.000 67.001 134002.000 Four
( ELECTRICAL mm. point Zero
Thousand
WORKS) Zero One
AND Two
One Ten
Hundred Thousand
PART-C-i : GATE
Earthwork in excavation in foundation trenches up to 1.5 m and Sixty- AND
78 HOUSE ( CIVIL 3.b Cum 60.000 168.001 10080.060
depth and maximum 10 m lead Eight point Eighty
WORKS)
Zero Zero point Zero
One Six
One
Hundred Nine
PART-C-i : GATE and Hundred
Added rate for each additional 0.5 meter depth exceeding 1.5
79 HOUSE ( CIVIL 3.c Cum 5.000 198.001 Ninety- 990.005 and Ninety
meter to 2.0 meter Depth
WORKS) Eight point point Zero
Zero Zero Zero Five
One
Five
Four Thousand
Hundred Six
PART-C-i : GATE and Hundred
Bailing out of trapped water caused by inundation or rain, by
80 HOUSE ( CIVIL 4 hour 12.000 474.001 Seventy- 5688.012 and
pump from foundation trenches.
WORKS) Four point Eighty-
Zero Zero Eight point
One Zero One
Two
One
Sand filling in foundation trenches and plinth with sand Twelve
Thousand
having min. F.M. 1.2 in 150 mm in layers including leveling, Thousand
Two
PART-C-i : GATE watering and compaction to achieve minimum dry density of Nine
Hundred
81 HOUSE ( CIVIL 5 95% with optimum moisture content (Modified proctor test) Cum 10.000 1296.001 12960.010 Hundred
and
WORKS) by ramming each layer up to finished level as per design and Sixty
Ninety-Six
supplied by the design office only, all complete and accepted point Zero
point Zero
by the Engineer-in-charge. One
Zero One
Forty-Four
Six Thousand
One layer brick flat soling in foundation or in floor with first Hundred Five
PART-C-i : GATE
class/picked jhama bricks (BDS 208) including preparation of and Thirty- Hundred
83 HOUSE ( CIVIL 7 Sqm 70.000 636.001 44520.070
bed and filling the interstices with local sand, leveling etc. Six point and
WORKS)
complete and accepted by the Engineer-in-charge. Zero Zero Twenty
One point Zero
Seven
Two
Thousand
Supplying and laying of single layer polythene sheet Forty-
PART-C-i : GATE Three
weighing one kilogram per 6.5 square meter in floor or any Seven
84 HOUSE ( CIVIL 8 Sqm 50.000 47.001 2350.050 Hundred
where below cement concrete complete in all respect and point Zero
WORKS) and Fifty
accepted by Engineer-in-charge. Zero One
point Zero
Five
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 9/80
3/11/24, 2:55 PM View Form
''Lean / blinding concrete (1:3:6) in foundation or in floor with Four
Nine
cement, sand (F.M. 1.2) and picked jhama brick chips Thousand
Thousand
including breaking of chips, screening, mixing, laying, Six
Three
PART-C-i : GATE compacting to required level and curing for at least 7 days Hundred
Hundred
85 HOUSE ( CIVIL 9 including the supply of water, electricity, costs of tools & Cum 0.500 9362.001 4681.001 and
and Sixty-
WORKS) plants and other charges etc. all complete and accepted by Eighty-
Two point
the Engineer-in-charge.(Cement: CEM-II/B-M) One point
Zero Zero
a) Lean / blinding concrete in foundation (1:3:6) with cement, Zero Zero
One
brick chips and sand of F.M. 1.2'' One
Twenty-
Brick works with first class bricks with cement sand (F.M. 1.2) Nine Two
mortar (1:6) in foundation and plinth, filling the Thousand Thousand
PART-C-i : GATE joints/interstices fully with mortar, racking out the joints, One Eight
87 HOUSE ( CIVIL 11 cleaning and soaking the bricks at least for 24 hours before Cum 2.500 9140.001 Hundred 22850.003 Hundred
WORKS) use and curing at least for 7 days etc. all complete including and Forty and Fifty
cost of water, electricity and other charges and accepted by point Zero point Zero
the Engineer-in-charge. (Cement: CEM-II/B-M) Zero One Zero
Three
''Brick works with first class bricks with cement sand (F.M.
Two Lakh
1.2) mortar (1:4) in exterior walls including filling the
Ten Thirty-Two
interstices with mortar, raking out joints, cleaning and socking
Thousand Thousand
the bricks at least for 24 hours before use and washing of
PART-C-i : GATE AND Two
sand, necessary scaffolding, curing at least for 7 days etc. all
88 HOUSE ( CIVIL 12 Cum 23.000 10097.001 Ninety- 232231.023 Hundred
complete including cost of water, electricity and other
WORKS) Seven and Thirty-
charges (measurement to given as 250 mm width for one
point Zero One point
brick length and 375 mm for one brick and a half brick length)
Zero One Zero Two
accepted by the Engineer-in-charge. (Cement: CEM-II/B-M)
Three
i) Ground floor''
''125 mm brick works with first class bricks with cement sand Twenty-
(F.M. 1.2) mortar (1:4) and making bond with connected walls One One
including necessary scaffolding, raking out joints, cleaning Thousand Thousand
PART-C-i : GATE and soaking the bricks for at least 24 hours before use and Four One
89 HOUSE ( CIVIL 13 washing of sand, curing at least for 7 days in all floors Sqm 15.000 1408.001 Hundred 21120.015 Hundred
WORKS) including cost of water, electricity and other charges etc. all and Eight and
complete and accepted by the Engineer-in-charge. (Cement: point Zero Twenty
CEM-II/B-M) Zero One point Zero
i) Ground floor'' One Five
93 PART-C-i : GATE 16.2.a ''2) FORM WORK (Steel) Sqm 19.000 582.001 Five 11058.019 Eleven
HOUSE ( CIVIL Centering and shuttering, including strutting, propping etc. Hundred Thousand
WORKS) (The formwork must be rigid enough both in and out of plane, and AND Fifty-
to make the concrete surface true to the designed shape and Eighty- Eight point
size by using necessary MS sheets of minimum 16 BWG, Two point Zero One
angles of minimum size 40 mm x 40 mm x 5 mm, flat bars Zero Zero Nine
One
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 10/80
3/11/24, 2:55 PM View Form
etc.) and removal of form for:
a) Individual & combined footing''
Twenty
PART-C-i : GATE One Lakh
''Foundation Beam Thousand
94 HOUSE ( CIVIL 16.1.b Cum 5.000 20000.001 100000.005 point Zero
1) Casting'' point Zero
WORKS) Zero Five
Zero One
Nineteen
Four
Thousand
Hundred
Seven
PART-C-i : GATE and
Hundred
95 HOUSE ( CIVIL 16.2.b 2) Form Work/Shuttering (steel) Sqm 40.000 493.001 Ninety- 19720.040
and
WORKS) Three
Twenty
point Zero
point Zero
Zero One
Four
Four Lakh
Twenty
PART-C-i : GATE ''Pedestals, column, RCC Wall etc. Twenty
Thousand
96 HOUSE ( CIVIL 16.1.c 1) Casting Cum 21.000 20000.001 420000.021 Thousand
point Zero
WORKS) i) Ground floor'' point Zero
Zero One
Two One
Seventy
Five
Thousand
Hundred
Four
PART-C-i : GATE and
''2) Form Work/Shuttering (steel) Hundred
97 HOUSE ( CIVIL 16.2.c Sqm 135.000 522.001 Twenty- 70470.135
i) Ground floor'' and
WORKS) Two point
Seventy
Zero Zero
point One
One
Three Five
Sixty
Twenty
PART-C-i : GATE ''Tee beam, L-beam and Rectangular beam Thousand
Thousand
98 HOUSE ( CIVIL 16.1.d 1) Casting Cum 3.000 20000.001 60000.003 point Zero
point Zero
WORKS) i) Ground floor'' Zero
Zero One
Three
Twelve
Five Thousand
Hundred Six
PART-C-i : GATE and Hundred
''2) Form Work/Shuttering (steel)
99 HOUSE ( CIVIL 16.2.d Sqm 22.000 574.001 Seventy- 12628.022 and
i) Ground floor''
WORKS) Four point Twenty-
Zero Zero Eight point
One Zero Two
Two
One Lakh
Twenty
PART-C-i : GATE ''Floor/ Roof Slab Twenty
Thousand
100 HOUSE ( CIVIL 16.1.e 1) Casting Cum 6.000 20000.001 120000.006 Thousand
point Zero
WORKS) i) Ground floor'' point Zero
Zero One
Zero Six
Twenty-
Five
Nine
Hundred
Thousand
PART-C-i : GATE and
''2) Form Work/ Shuttering (steel) Eight
101 HOUSE ( CIVIL 16.2.e Sqm 50.000 597.001 Ninety- 29850.050
i) Ground floor'' Hundred
WORKS) Seven
and Fifty
point Zero
point Zero
Zero One
Five
Twenty Eighty
PART-C-i : GATE ''Cornice, false slab, railing, drop wall, parapet etc.
Thousand Thousand
104 HOUSE ( CIVIL 17.1.b 1) Casting Cum 4.000 20000.001 80000.004
point Zero point Zero
WORKS) i) Ground floor''
Zero One Zero Four
105 PART-C-i : GATE 17.2.b ''2) Form Work/Shuttering (steel) Sqm 70.000 541.001 Five 37870.070 Thirty-
HOUSE ( CIVIL Cornice, false slab, railing, drop wall, parapet etc. Hundred Seven
WORKS) i) Ground floor'' and Forty- Thousand
One point Eight
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 11/80
3/11/24, 2:55 PM View Form
Zero Zero Hundred
One and
Seventy
point Zero
Seven
Sixty-
Seven
Minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:4)
Three Thousand
with fresh cement to both inner-and outer surface of wall,
Hundred Seven
PART-C-i : GATE finishing the corner and edges including washing of sand,
and Hundred
110 HOUSE ( CIVIL 22 cleaning the surface, curing at least for 7 days, cost of water, Sqm 215.000 315.001 67725.215
Fifteen and
WORKS) electricity, scaffolding and other charges etc. all complete in
point Zero Twenty-
all respect as per drawing and accepted by the Engineer-in-
Zero One Five point
charge. (Cement: CEM-II/B-M) i) Ground floor
Two One
Five
114 PART-C-i : GATE 26 Rule pointing to brick wall with cement sand (F.M. 1.2) mortar Sqm 220.000 239.001 Two 52580.220 Fifty-Two
HOUSE ( CIVIL (1:2) with fresh cement and raking out the joints, curing at Hundred Thousand
WORKS) least for 7 days, cost of water, electricity, scaffolding and and Thirty- Five
other charges etc. all complete in all respect as per drawing Nine point Hundred
and Eighty
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 12/80
3/11/24, 2:55 PM View Form
and accepted by the Engineer-in-charge. (Cement: CEM-II/B- Zero Zero point Two
M) One Two
One
Eight
Thousand
Thousand
Three
PART-C-i : GATE AND
''GP (homogeneous) 300 mm x 300 mm floor tiles Hundred
116 HOUSE ( CIVIL 27.b Sqm 6.000 1347.001 8082.006 Eighty-
i) Ground floor'' and Forty-
WORKS) Two point
Seven
Zero Zero
point Zero
Six
Zero One
Thirty-One
Three
''Labour cost for making moulding in marble stone/ Tiles as Thousand
Hundred
per architectural drawing including cutting, grinding, finishing, Nine
PART-C-i : GATE and
supplying necessary equipment etc. complete in all respect Hundred
118 HOUSE ( CIVIL 29 Rm 80.000 399.001 Ninety- 31920.080
and accepted by the Engineer in Charge. (Cement: CEM- and
WORKS) Nine point
II/B-M). Twenty
Zero Zero
a) 12 mm thick marble/ Tiles stone'' point Zero
One
Eight
One
One Thousand
Supplying, fitting and fixing M.S. flat bar clamp of 150 mm x
Hundred Nine
PART-C-i : GATE 38 mm x 6 mm size having bifurcated ends to door and
and Thirty- Hundred
120 HOUSE ( CIVIL 31 window frames with necessary rowel plug, screws etc. each 15.000 131.001 1965.015
One point and Sixty-
WORKS) including cutting grooves in chowkat if necessary etc. all
Zero Zero Five point
complete and accepted by the Engineer-in-charge.
One Zero One
Five
123 PART-C-i : GATE 34 ''Supplying, fitting and fixing in Aluminium door frames, Sqm 6.000 2879.001 Two 17274.006 Seventeen
HOUSE ( CIVIL windows, partitions and curtain wall distortion free glass of Thousand Thousand
WORKS) approved quality and shade including cost of fitting fixing all Eight Two
necessary accessories etc. complete in all respect as per Hundred Hundred
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 13/80
3/11/24, 2:55 PM View Form
drawing and accepted by the Engineer-in-charge. and and
6 mm thick clear tempered glass'' Seventy- Seventy-
Nine point Four point
Zero Zero Zero Zero
One Six
Seven
Five Thousand
Premium French polishing to door and window frames,
Hundred Two
PART-C-i : GATE shutter and any other wooden surface by three coats over a
and Hundred
127 HOUSE ( CIVIL 38 coat of priming including putty, cleaning, finishing and Sqm 14.000 519.001 7266.014
Nineteen and Sixty-
WORKS) polishing with sand paper etc. all complete in all floors and
point Zero Six point
accepted by the Engineer-in-charge.
Zero One Zero One
Four
Standard Duco paint with approved best quality and colour Ten
delivered from authorized local agent of the manufacturer in Two Thousand
a sealed container, having high water resistance, high Thousand Four
PART-C-i : GATE bondibility, flexibility property; using specified brand thinner AND Hundred
128 HOUSE ( CIVIL 39 applying to metallic or wooden surface by brass/roller/spray Sqm 5.000 2099.001 Ninety- 10495.005 and
WORKS) machine in 2 coats over single coat primer coating including Nine point Ninety-
cleaning, drying, making free from dirt, grease, wax, Zero Zero Five point
removing all chalked and scaled materials, all complete in all One Zero Zero
floors and accepted by the Engineer-in-charge. Five
Two
One Thousand
Thousand One
PART-C-i : GATE Supplying, fitting and fixing rim/ round door lock of approved
AND Fifty- Hundred
130 HOUSE ( CIVIL 41 quality including all necessary tools and accessories etc. all Each 2.000 1058.001 2116.002
Eight point and
WORKS) complete and accepted by the Engineer-in-charge.
Zero Zero Sixteen
One point Zero
Zero Two
Six
Three
Hundred
Supplying, fitting and fixing best quality heavy type 19 mm Hundred
PART-C-i : GATE and
dia and 300 mm long hasp bolt including cutting grooves in and Forty-
131 HOUSE ( CIVIL 42 Each 2.000 344.001 688.002 Eighty-
door shutter and frames, screws etc. all complete approved Four point
WORKS) Eight point
and accepted by the Engineer-in-charge. SS Hasp Bolt Zero Zero
Zero Zero
One
Two
Three Three
Hundred Hundred
Supplying, fitting and fixing of best quality magnetic door
PART-C-i : GATE and and
holder of approved quality including all necessary tools and
132 HOUSE ( CIVIL 43 Each 1.000 374.001 Seventy- 374.001 Seventy-
accessories all complete and accepted by the Engineer-in-
WORKS) Four point Four point
charge.
Zero Zero Zero Zero
One One
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 14/80
3/11/24, 2:55 PM View Form
''Manufacturing, supplying, fitting and fixing double leaf SS
Main gate made with 2mm thick 75mm x 75mm ss hollow
box as outer frame, 1.5 mm thick 50mm X 25mm ss hollow
Six Lakh
box as inner frame with 1.5 mm thick, 19 mm x 19 mm SS Twenty-
Fifty-
hollow box for fencing @75mm c/c, 900 mm Long 25mm dia Nine
Three
SS box handle, 350 mm long 20mm dia SS hatch bolt, Thousand
Thousand
150mm x 38mm hinge base plate, 50 mm x 8 mm S.S plate Seven
PART-C-i : GATE Nine
for bottom rail, 75 mm dia SS wheel, 6 mm thick 12'' x 13'' Hundred
133 HOUSE ( CIVIL 44 Sqm 22.000 29724.001 653928.022 Hundred
box SS 16 gauge plate for locking arangement, 100 mm x 10 and
WORKS) and
mm dia S.S. Rowel bolt, SS pad lock, fitting-fixing the gate by Twenty-
Twenty-
cutting hole and mending good the damages by pouring Four point
Eight point
concrete(1:2:4) into the holes and hoisting the gate in Zero Zero
Zero Two
position with necessary carriage,electrodes, curing, One
Two
polishing, finishing, etc.complete as per drawing and design
and accepted by the Engineer-in-charge.
For S.S. Grade A304''
Three
Supplying, fitting, fixing, and installation of ornamental type Four
Lakh
M.S. mother board diagram shape of approve design and Thousand
Seventeen
shape with 50 mm x 25 mm M.S. box of 3 mm thickness and Eight
Thousand
PART-C-i : GATE 150 mm x 100 mm ring of 3 mm thickness are placed as per Hundred
Six
136 HOUSE ( CIVIL 47 drawing and design. including fabrication, riveting, welding as Sqm 65.000 4887.001 and 317655.065
Hundred
WORKS) and where necessary, painting 2 (two) coats with approved Eighty-
and Fifty-
best quality paint over a coat of anticorrosive painting etc. all Seven
Five point
complete as per drawing, design and accepted by the point Zero
Zero Six
Engineer-in-charge. (Rate is including the cost of paint). Zero One
Five
Five Lakh
Supply, fabrication and installation of built-up sections i.e.
One Thirty-
columns, beams, rafters, bracings, struts etc. (up to level-4)
Hundred Four
PART-C-i : GATE from steel plates conforming to ASTM A572, with a minimum
and Thirty- Thousand
141 HOUSE ( CIVIL 52 yield strength of 345 MPa, including the cost of testing of Kg 3900.000 137.001 534303.900
Seven Three
WORKS) plates, applicaton of red/ grey-oxide primer etc. all complete
point Zero Hundred
as per drawing, specification and direction of Engineer-in-
Zero One and Three
charge.
point Nine
142 PART-C-i : GATE 53 Supply and fixing of connection bolts of variable diameter Kg 40.000 361.001 Three 14440.040 Fourteen
HOUSE ( CIVIL with nut and washer according to ''ASTM A325 Type 1 or Hundred Thousand
WORKS) equivalent? with Fu =720 Mpa, including the cost of testing of and Sixty- Four
One point Hundred
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 15/80
3/11/24, 2:55 PM View Form
bolts, all complete as per drawing, specification and direction Zero Zero and Forty
of Engineer-In-Charge. One point Zero
Four
147 PART-C-ii : GATE 3 ''Supplying of country made glazed vitreous W/H wash basin Each 1.000 8443.001 Eight 8443.001 Eight
HOUSE of any color including pedestal. Thousand Thousand
(SANITARY Four Four
WORKS) The sanitary ware shall conform BDS1162:2014. The glaze Hundred Hundred
shall be thoroughly fused to body. The minimum thickness of and Forty- and Forty-
body at any section shall be 5 mm. When assembled Three Three
together and when examined from a distance of 60 cm, the point Zero point Zero
outer surface shall not show to the unaided eye, blemishes Zero One Zero One
or defects in excess of those listed in BDS standard. The
mean value of water absorption shall not be greater than
0.5% of the ware when dry. When tested with chemical
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 16/80
3/11/24, 2:55 PM View Form
solutions (Acetic acid, Citric acid, Detergent, Hydrochloric
acid, Sodium hydroxide, Sodium stearate and Sulfuric acid of
various strength) as per BDS1162:2014 procedure, none of
the test pieces should suffer any loss of reflectivity on the
glaze. There shall be no crazing and no stain on the ware.
The materials used for making glaze shall not contain lead
compound. In case of certain coloring oxides used for
making colored glaze, the lead content, if any, shall not
exceed 5 percent of the weight of the glaze materials.
Appliances shall be clearly and indelibly marked at a
prominent place, visible even after the appliances are
installed with the following: a) manufacturer's name and/or
registered trademark, b) the number of Bangladesh standard
and c) country of origin. Each product shall also be marked
with the BSTI Certification Mark.
Two Two
''Supplying, fitting and fixing of 5 mm thick unframed super
Thousand Thousand
PART-C-ii : GATE quality double coated mirror with all necessary fitting
Five Five
HOUSE including making holes in walls and mending good the
148 4 Each 1.000 2590.001 Hundred 2590.001 Hundred
(SANITARY damages with cement mortar (1:4) etc. all complete
and Ninety and Ninety
WORKS) approved and accepted by the Engineer-in-charge.
point Zero point Zero
Local Mirror, 5 mm thickness''
Zero One Zero One
One One
Supplying, fitting and fixing of super quality 600 mm x 125
Thousand Thousand
PART-C-ii : GATE mm coloured glass (plate) shelf having 5 mm thickness with
Eight Eight
HOUSE fancy C.P. brackets, screws and frames including making
149 5 Each 1.000 1830.001 Hundred 1830.001 Hundred
(SANITARY holes in walls and mending good the damages with cement
and Thirty and Thirty
WORKS) mortar (1:4) etc. all complete approved and accepted by the
point Zero point Zero
Engineer- in- charge.
Zero One Zero One
''Supplying, fitting and fixing of country made best quality Seven Seven
PART-C-ii : GATE towel rail/ ring/ shelf minimum 20 mm in dia with C.P. holder Hundred Hundred
HOUSE including making holes in walls and mending good the and and
150 6 Each 1.000 718.001 718.001
(SANITARY damages with cement mortar (1:4) etc. all complete Eighteen Eighteen
WORKS) approved and accepted by the Engineer- in- charge. point Zero point Zero
600 mm long C.P. single towel rail'' Zero One Zero One
Five Five
''Supplying, fitting and fixing of best quality toilet paper holder
PART-C-ii : GATE Hundred Hundred
of standard size including making holes in walls and mending
HOUSE and Sixty- and Sixty-
151 7 good the damages with cement mortar (1:4) etc. all complete Each 1.000 563.001 563.001
(SANITARY Three Three
approved and accepted by the Engineer- in- charge.
WORKS) point Zero point Zero
Stainless steel toilet paper holder''
Zero One Zero One
One
Six
Thousand
''Supplying, fitting and fixing of standard size country made Hundred
PART-C-ii : GATE Two
soap tray including making holes in walls and mending good and
HOUSE Hundred
152 8 the damages with cement mortar (1:4) etc. all complete Each 2.000 628.001 Twenty- 1256.002
(SANITARY and Fifty-
approved and accepted by the Engineer- in- charge. Eight point
WORKS) Six point
Stainless steel soap tray '' Zero Zero
Zero Zero
One
Two
Three
''Supplying, fitting and fixing of floor grating net in traps or in Six
Hundred
PART-C-ii : GATE drains including making holes in walls/floors and mending Hundred
and
HOUSE good the damages with cement mortar (1:4) etc. all complete and Fifty-
153 9.a Each 2.000 328.001 Twenty- 656.002
(SANITARY approved and accepted by the Engineer- in- charge. of Six point
Eight point
WORKS) following type Zero Zero
Zero Zero
a) Approx. 100~125 mm dia stainless steel floor grating net'' Two
One
One
Five
Thousand
PART-C-ii : GATE Hundred
One
HOUSE b) 125 mm dia convex cast iron grating on rain water down and Fifty-
154 9.b Each 2.000 555.001 1110.002 Hundred
(SANITARY pipe (roof top) Five point
and Ten
WORKS) Zero Zero
point Zero
One
Zero Two
Fifteen
Supplying, fitting and fixing of 100 mm inside diameter & wall Nine Thousand
thickness 2.7 mm - 3.4 mm best quality uPVC rain water Hundred Eight
PART-C-ii : GATE
down pipe fitting, fixed in position with head and shoes, and Hundred
HOUSE
155 10 bends, min.20 mm width F.I. Bar clamp and nails, and Rm 16.000 993.001 Ninety- 15888.016 and
(SANITARY
including all accessories such as round grating/domed roof Three Eighty-
WORKS)
grating, bands, sockets approved and accepted by the point Zero Eight point
Engineer- in- charge. Zero One Zero One
Six
157 PART-C-ii : GATE 11.b b) 100 mm inside dia wall thickness 3.4 mm - 4.0 mm Rm 40.000 881.001 Eight 35240.040 Thirty-Five
HOUSE Hundred Thousand
(SANITARY and Two
WORKS) Eighty- Hundred
One point and Forty
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 17/80
3/11/24, 2:55 PM View Form
Zero Zero point Zero
One Four
Three
Three
Hundred
PART-C-ii : GATE Thousand
and
HOUSE AND
159 12.ii ii) 19 mm dia wall thickness 2.9 mm - 3.4 mm Rm 8.000 387.001 Eighty- 3096.008
(SANITARY Ninety-Six
Seven
WORKS) point Zero
point Zero
Zero Eight
Zero One
Four Sixty-Eight
PART-C-ii : GATE Hundred Thousand
HOUSE and Fifty- One
160 12.iii iii) 25 mm dia wall thickness 3.4 mm - 4.0 mm Rm 150.000 454.001 68100.150
(SANITARY Four point Hundred
WORKS) Zero Zero point One
One Five
Six
Hundred
PART-C-ii : GATE Five
and
HOUSE Thousand
161 12.iv iv) 32 mm dia wall thickness 3.6 mm - 4.2 mm Rm 8.000 625.001 Twenty- 5000.008
(SANITARY point Zero
Five point
WORKS) Zero Eight
Zero Zero
One
Four Nine
PART-C-ii : GATE ''Supplying, fitting and fixing of best quality G.I. gate valve Hundred Hundred
HOUSE with sealant etc. complete approved and accepted by the and Fifty- and
162 13.(i) Each 2.000 459.001 918.002
(SANITARY Engineer- in- charge. Nine point Eighteen
WORKS) i) 12 mm brass gate valve'' Zero Zero point Zero
One Zero Two
Six Six
PART-C-ii : GATE Hundred Hundred
HOUSE and Thirty- and Thirty-
163 13.(ii) ii) 20 mm brass gate valve Each 1.000 633.001 633.001
(SANITARY Three Three
WORKS) point Zero point Zero
Zero One Zero One
Two
Thousand
Seven
Nine
PART-C-ii : GATE Hundred
Hundred
HOUSE and Forty-
164 13.(iii) iii) 25 mm brass Gate valve Each 4.000 746.001 2984.004 and
(SANITARY Six point
Eighty-
WORKS) Zero Zero
Four point
One
Zero Zero
Four
One One
Thousand Thousand
Two Two
PART-C-ii : GATE
Hundred Hundred
HOUSE
165 13.(iv) iv) 40 mm brass gate valve Each 1.000 1221.001 and 1221.001 and
(SANITARY
Twenty- Twenty-
WORKS)
One point One point
Zero Zero Zero Zero
One One
One
Three
Hundred
PART-C-ii : GATE ''Supplying, fitting and fixing of G.I. Union with sealant etc. Hundred
and
HOUSE complete in all respects approved and accepted by the and Fifty-
166 14.(i) Each 2.000 177.001 Seventy- 354.002
(SANITARY Engineer- in- charge. Four point
Seven
WORKS) i) 12 mm dia G.I. Union'' Zero Zero
point Zero
Two
Zero One
Two Two
Hundred Hundred
PART-C-ii : GATE
and and
HOUSE
167 14.(ii) ii) 20 mm dia G.I. Union Each 1.000 228.001 Twenty- 228.001 Twenty-
(SANITARY
Eight point Eight point
WORKS)
Zero Zero Zero Zero
One One
Two
One
Hundred
PART-C-ii : GATE Thousand
and
HOUSE AND
168 14.(iii) iii) 25 mm dia G.I. Union Each 4.000 274.001 Seventy- 1096.004
(SANITARY Ninety-Six
Four point
WORKS) point Zero
Zero Zero
Zero Four
One
Four Four
Hundred Hundred
PART-C-ii : GATE
and and
HOUSE
169 14.(iv) iv) 40 mm dia G.I. Union Each 1.000 491.001 Ninety- 491.001 Ninety-
(SANITARY
One point One point
WORKS)
Zero Zero Zero Zero
One One
170 PART-C-ii : GATE 15.(i) ''Supplying different inside dia best quality uPVC clean out / Each 6.000 671.001 Six 4026.006 Four
HOUSE trap having specific gravity 1.35 -1.45 and other physical, Hundred Thousand
(SANITARY chemical, themal, fire resistivity properties etc. as per BSTI and AND
WORKS) approved manufacturer standards or ASTM, BS/ISO/IS Seventy- Twenty-
standards, fitting and fixing in position etc. complete One point Six point
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 18/80
3/11/24, 2:55 PM View Form
approved and accepted by the Engineer- in- charge. Zero Zero Zero Zero
i) 100 mm dia uPVC Y or T - Y Cleanout'' One Six
Four Eight
PART-C-ii : GATE
Hundred Hundred
HOUSE
171 15.(ii) ii) 100 mm dia uPVC ?P? or ?S? trap Each 2.000 440.001 and Forty 880.002 and Eighty
(SANITARY
point Zero point Zero
WORKS)
Zero One Zero Two
Eleven Eleven
Thousand Thousand
Nine Nine
PART-C-ii : GATE Supplying, fitting and fixing of food graded plastic overhead
Hundred Hundred
HOUSE water reservoir /tank including all necessary fittings,
172 16 Each 1.000 11998.001 and 11998.001 and
(SANITARY hardware and consumables etc. all complete approved and
Ninety- Ninety-
WORKS) accepted by the Engineer- in- charge. 1000 liter capacity
Eight point Eight point
Zero Zero Zero Zero
One One
One
Nine Thousand
Hundred Nine
PART-C-ii : GATE
and Hundred
HOUSE
175 18.b b) CP angle stop cock Each 2.000 988.001 Eighty- 1976.002 and
(SANITARY
Eight point Seventy-
WORKS)
Zero Zero Six point
One Zero Zero
Two
Two Two
Thousand Thousand
Two Two
PART-C-ii : GATE ''Supplying and fitting-fixing Chromium plated (CP) Shower
Hundred Hundred
HOUSE head. all complete approved and accepted by the Engineer-
177 20 Each 1.000 2276.001 and 2276.001 and
(SANITARY in- charge.
Seventy- Seventy-
WORKS) Moving type 150 mm CP shower head''
Six point Six point
Zero Zero Zero Zero
One One
One
Two
Hundred
PART-C-ii : GATE Hundred
''Supplying, fitting and fixing of 12 mm dia connection pipe and
HOUSE and Forty-
178 21 approved and accepted by the Engineer- in- charge. Each 2.000 124.001 Twenty- 248.002
(SANITARY Eight point
600 mm long plastic flexible lead (connection) pipe'' Four point
WORKS) Zero Zero
Zero Zero
Two
One
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 19/80
3/11/24, 2:55 PM View Form
''Groove cutting in brick work and R.C.C work, including cost
for concealing of water distribution pipe work (12 mm and 20
Three
mm dia) in brick wall by cutting groove in wall, lintel, beam Seven
Hundred
PART-C-ii : GATE etc. by any means carefully without damaging the structure Thousand
and
HOUSE and filling the grooves with C.C (4:2:1) after laying of pipe Eight
179 22.a Rm 24.000 325.001 Twenty- 7800.024
(SANITARY including cost of scaffolding, finishing, curing etc. all Hundred
Five point
WORKS) complete approved and accepted by the Engineer- in- point Zero
Zero Zero
charge. Two Four
One
a) Groove size 40 mm x 40 mm (For laying 12 mm to 20 mm
dia pipes)''
Five One
PART-C-ii : GATE Hundred Thousand
HOUSE b) Groove size 75 mm x 75 mm (For 25 mm to 40 mm dia and Thirty- AND
180 22.b Rm 2.000 535.001 1070.002
(SANITARY pipes) Five point Seventy
WORKS) Zero Zero point Zero
One Zero Two
Twelve Twelve
Thousand Thousand
PART-C-ii : GATE b) Clear 600 mm x 600 mm and depth 750 mm to 900 mm, Five Five
HOUSE average 825 mm for single 300 mm dia R.C.C. pipes and Hundred Hundred
183 24.b Each 1.000 12554.001 12554.001
(SANITARY 375 mm and 400 mm PVC pipe with pit cover and 450 mm and Fifty- and Fifty-
WORKS) dia C.I. man-hole cover. Four point Four point
Zero Zero Zero Zero
One One
Eighteen Eighteen
''Supplying, fitting, fixing of foreign made best quality
Thousand Thousand
Reverse Osmosis Water Purifier (Kent/ Unilever/ Vapor water
Five Five
PART-C-ii : GATE purifier or equivalent brand) for purification of water by
Hundred Hundred
HOUSE reverse osmosis system to have potable water conforming
186 27 Each 1.000 18577.001 and 18577.001 and
(SANITARY WHO standard and Bangladesh concentration parameters
Seventy- Seventy-
WORKS) including installation charge, carriage, sundries etc. complete
Seven Seven
approved and accepted by the Engineer- in- charge.
point Zero point Zero
Water purification capacity: 10 L/hr, storage 6 litre; RO+MF''
Zero One Zero One
187 PART-C-iii : GATE 1 ''Concealed conduit point wiring (BYM) (without switch): Point 25.000 1261.001 One 31525.025 Thirty-One
HOUSE Concealed conduit wiring for following point looping at the Thousand Thousand
(ELECTRICAL switch board with earth terminal with 1C-2x1.5 sqmm PVC Two Five
WORKS) insulated and sheathed stranded cable (BYM) & same size Hundred Hundred
PVC insulated ECC (BYA) (Green / White color) including and Sixty- and
circuit wiring with IC-2x2.5 sqmm PVC insulated and One point Twenty-
sheathed stranded cable (BYM) & same size PVC insulated Zero Zero Five point
ECC (BYA) Green / White color through PVC conduit (one One Zero Two
conduit from switch board to common point on ceiling is Five
considered to draw 3 pair of cable ) of reputed manufacturer
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 20/80
3/11/24, 2:55 PM View Form
of minimum 25 mm dia & 1.5 mm wall thickness complete
with 18 SWG GP sheet / PVC switch board & pull box with
3mm thick ebonite sheet cover, without switch, fixing
materials etc.(without switch) as required including mending
the damages good. All electrical contacts shall be of brass /
copper connected through connector or soldering (no twisting
shall be allowed) and cables shall be manufactured and
tested according to relevant IEC / BDS / BS / VDE standards
and as per detailed specification mentioned in Annexure-1.
The work shall be carried out as per direction & approval of
the Engineer.
Cable manufacturer(s) must have valid test certificate (within
last seven years ) from internationally accrediated laboratory
(like CPRI, KEMA etc) accepted / approved by the Engineer.
1.1) Light/ exhaust or wall bracket fan point''
Two
PART-C-iii : GATE Twenty-
1C-2x2.5sqmm (BYM) cable with 2.5 sqmm (BYA) ECC wire Hundred
HOUSE Six
191 4.2 through PVC pipe of minimum inner dia 25 mm having wall Rm 100.000 260.001 and Sixty 26000.100
(ELECTRICAL Thousand
thickness of 1.7 mm point Zero
WORKS) point One
Zero One
Three Sixteen
PART-C-iii : GATE Hundred Thousand
1C-2x4.0 sqmm (BYM) cable with 4 sqmm (BYA) ECC wire
HOUSE and Thirty- Nine
192 4.3 through PVC pipe of minimum inner dia 25 mm having wall Rm 50.000 338.001 16900.050
(ELECTRICAL Eight point Hundred
thickness of 1.7 mm
WORKS) Zero Zero point Zero
One Five
193 PART-C-iii : GATE 5 ''SURFACE WIRING (NYY) (THROUGH PVC CONDUIT) : Rm 150.000 1711.001 One 256650.150 Two Lakh
HOUSE Surface conduit wiring with the following PVC insulated and Thousand Fifty-Six
(ELECTRICAL sheathed stranded cable (NYY) / XLPE insulated and PVC Seven Thousand
WORKS) sheathed stranded cable (2XY) & PVC insulated Green / Hundred Six
Yellow bi-colour , ECC wire (BYA) through PVC conduit of and Hundred
reputed manufacturer complete with fixing materials, other Eleven and Fifty
accessories etc. as required including mending the damages point Zero point One
good. All electrical contacts shall be of brass / copper Zero One Five
connected through connector or soldering (no twisting shall
be allowed) and cables shall be manufactured and tested
according to IEC / BS / VDE standards along with relevant
BDS standard as per detailed specification mentioned in
Annexure-1. The work shall be carried out as per direction &
approval of the Engineer In Charge. Cable manufacturer(s)
must have valid type test certificate (within last seven years)
from internationally accredited laboratory (like CPRI, KEMA
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 21/80
3/11/24, 2:55 PM View Form
etc.) accepted / approved by the Engineer In Charge .
5.1) 1C-4x16sqmm (NYY / 2XY) with 16 sqmm (BYA) ECC
wire through PVC pipe of minimum inner dia 40 mm having
wall thickness of 2.2 mm''
Seven Seven
PART-C-iii : GATE Hundred Hundred
''5 - 10 Amps.
HOUSE and and
195 6.b Made in HONGKONG / MALAYSIA / SINGAPORE / S each 1.000 715.001 715.001
(ELECTRICAL Fifteen Fifteen
KOREA / THAILAND''
WORKS) point Zero point Zero
Zero One Zero One
''GANG SWITCH:
Providing & fixing 250 volts. 5 / 6 amps (minimum) concealed
type following switch / switch socket manufactured and Two Two
PART-C-iii : GATE tested in accordance with relevant IEC / VDE / NEMA / BS / Hundred Hundred
HOUSE JIS standards mounted on required size 18 SWG galvanized and and
196 7.1 each 1.000 218.001 218.001
(ELECTRICAL plain sheet / PVC board (Self-extinguishing 650oC) of 76.2 Eighteen Eighteen
WORKS) mm (3'''') depth. All electrical contacts shall be of brass / point Zero point Zero
copper. Made in HONGKONG / MALAYSIA / SINGAPORE / Zero One Zero One
S KOREA / THAILAND
7.1) One gang switch ''
One
Five Thousand
PART-C-iii : GATE Hundred Five
HOUSE and Hundred
197 7.2 Three gang switch each 3.000 514.001 1542.003
(ELECTRICAL Fourteen and Forty-
WORKS) point Zero Two point
Zero One Zero Zero
Three
One
Thousand
Seven
Five
PART-C-iii : GATE Hundred
Hundred
HOUSE and Sixty-
198 7.3 Four gang switch each 2.000 763.001 1526.002 and
(ELECTRICAL Three
Twenty-
WORKS) point Zero
Six point
Zero One
Zero Zero
Two
200 PART-C-iii : GATE 9 ''BATHROOM LIGHT FITTING: each 1.000 3184.001 Three 3184.001 Three
HOUSE Supply & fixing LED bathroom light fittings of the following Thousand Thousand
(ELECTRICAL specifications: One One
WORKS) Luminous efficacy: 80 lm/w(minimum), Hundred Hundred
Power Factor: minimum 0.95 and and
Colour Rendering Index(Ra) : Eighty- Eighty-
i) For Residential building Ra≥80 Four point Four point
ii) For office and other types of buildings 70≤Ra< 85 Zero Zero Zero Zero
Driver: Should be of IEC standard such as One One
MEANWELL/OSRAM/ENERGY+/SIGNIFY(PHILIPS) or
equivalent
LED chips :EPISTAR / OSRAM / SIGNIFY(PHILIPS) / CREE
/ BRIDGELUX or equivalent. Colour temperature : 3500K-
6500K (Warm-White)
Model & sample to be accepted / approved by the Engineer-
in-charge (with 2 years warranty).
Material: MS Sheet, Aluminium Sheet, Acrylic (thick-12mm)
L-400mm H-90mm P-40mm GLORIA cat No.GLML. 2106,
Energy+ Cat no-EPML-10029 (small), Cosmo Cat No-
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 22/80
3/11/24, 2:55 PM View Form
BDTCL-LML-01,
Asha Cat no-ACS ?LBB-2837 or equivalent. 15 Watt fittings.''
Six
Seven Thousand
PART-C-iii : GATE
Hundred Two
HOUSE
204 12.b 16 Amps. each 8.000 780.001 and Eighty 6240.008 Hundred
(ELECTRICAL
point Zero and Forty
WORKS)
Zero One point Zero
Zero Eight
Seven Seven
PART-C-iii : GATE
Hundred Hundred
HOUSE
205 12.c 20 Amps. each 1.000 780.001 and Eighty 780.001 and Eighty
(ELECTRICAL
point Zero point Zero
WORKS)
Zero One Zero One
Seven Seven
PART-C-iii : GATE
Hundred Hundred
HOUSE
206 12.d 25 Amps. each 1.000 780.001 and Eighty 780.001 and Eighty
(ELECTRICAL
point Zero point Zero
WORKS)
Zero One Zero One
''TPMCB :
Providing & fixing on a prepared board 500 volt grade Four Four
PART-C-iii : GATE following Triple pole miniature circuit Breaker (TPMCB) Thousand Thousand
HOUSE having minimum breaking capacity 6-KA /10 KA with thermal AND AND
207 13 each 1.000 4030.001 4030.001
(ELECTRICAL over-current and instantaneous electromagnetic short circuit Thirty Thirty
WORKS) release provision. point Zero point Zero
TPMCB accepted / approved by the engineer. Zero One Zero One
20 Amps.''
''TPMCCB:
Seven Seven
Providing & fixing on a prepared board 500 volt grade
Thousand Thousand
following triple-pole molded case circuit breaker (TPMCCB)
PART-C-iii : GATE Four Four
with thermal over-current and instantaneous electromagnetic
HOUSE Hundred Hundred
208 14 short circuit release provision, manufactured and tested in each 1.000 7466.001 7466.001
(ELECTRICAL and Sixty- and Sixty-
accordance with relevant IEC / VDE / NEMA / BS / JIS
WORKS) Six point Six point
standards.
Zero Zero Zero Zero
TPMCCB accepted / approved by the engineer.
One One
60 Amps. (minimum 10-KA)''
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 23/80
3/11/24, 2:55 PM View Form
''BOARD:
Supplying and fixing of almirah type 18 SWG metal board of
depth 228mm (6?) duly painted with powder coating with
epoxy polyester resin on all surfaces of board (gray / off-
white) having built in push type / suitable locking Eighteen Eighteen
arrangement including metal bridges of suitable size for fixing Thousand Thousand
PART-C-iii : GATE
of all electrical control devices complete with suitable Seven Seven
HOUSE
210 16 anchoring arrangement in wall / column and keeping sqm 1.000 18780.001 Hundred 18780.001 Hundred
(ELECTRICAL
provision for cable inlets and exits as required (only front and Eighty and Eighty
WORKS)
surface of the board will be considered for measurement). point Zero point Zero
(Manufactured by RECO / NASCO / C&S or equivalent Zero One Zero One
product of any other manufacturer) The front side of the
boards should be covered with required size tempered thick
fiber glass with rubber gaskets to observe the inside
arrangement. ''
''TELECOMMUNICATION CABLE:
Supplying and drawing of following sizes PVC insulated &
PART-C-iii : GATE sheathed twisted pair telecommunication cables having dia Thirty-
Seventeen
HOUSE of each core is 0.6 mm through prelaid pipes. Four point
211 17 Rm 500.000 34.001 17000.500 Thousand
(ELECTRICAL Cable manufacturer(s) must have valid test certificate from Zero Zero
point Five
WORKS) internationally accrediated laboratory (like CPRI, KEMA etc) One
approved / accepted by the Engineer.
a) 1C-4x0.282 sqmm (2 pair)''
''CO-AXIAL CABLE :
Supplying & drawing of following sizes PVC insulated & One Sixteen
PART-C-iii : GATE sheathed 75 ohm impedance co-axial cables through prelaid Hundred Thousand
HOUSE pipes. and Eight
212 18 Rm 150.000 112.001 16800.150
(ELECTRICAL Cable manufacturer(s) must have valid test certificate from Twelve Hundred
WORKS) internationally accrediated laboratory (like CPRI, KEMA etc) point Zero point One
approved/ accepted by the Engineer. Zero One Five
a) RG-11''
One
Thousand
PART-C-iii : GATE ''CABLE / SOCKET / FERULES : Sixty-
Three
HOUSE Supply and fixing of copper made sockets / ferules for Seven
213 19.a Each 20.000 67.001 1340.020 Hundred
(ELECTRICAL following size cables (need to be shown voltage rating.) point Zero
and Forty
WORKS) a) 16 sqmm'' Zero One
point Zero
Two
Seven
PART-C-iii : GATE Seventy-
Hundred
HOUSE Nine point
214 19.b 25 sqmm Each 10.000 79.001 790.010 and Ninety
(ELECTRICAL Zero Zero
point Zero
WORKS) One
One
''PVC PIPE :
Providing & laying of following PVC pipe (best quality PVC
PART-C-iii : GATE pipe of reputed manufacturer) embedded in wall / column /
Fifty point Ten
HOUSE ceiling / floor etc. with all accessories, 18 SWG GP sheet pull
215 20.a Rm 200.000 50.001 Zero Zero 10000.200 Thousand
(ELECTRICAL box with 3 mm thick ebonite sheet cover, fixing materials etc.
One point Two
WORKS) as required including mending the damages good.
a) Minimum inner dia 20 mm & minimum wall thickness 1.5
mm. ''
Six
PART-C-iii : GATE Sixty-
Thousand
HOUSE b) Minimum inner dia 25 mm & minimum wall thickness 1.7 Seven
216 20.b Rm 100.000 67.001 6700.100 Seven
(ELECTRICAL mm. point Zero
Hundred
WORKS) Zero One
point One
One Lakh
Seventy
One Thousand
PART-D-i : Hundred Five
INTERNAL RCC Earthwork in excavation in foundation trenches up to 1.5 m and Sixty- Hundred
218 1.b Cum 1015.000 168.001 170521.015
ROAD (CIVIL depth and maximum 10 m lead Eight point and
WORKS) Zero Zero Twenty-
One One point
Zero One
Five
One Thirteen
Hundred Thousand
PART-D-i :
and Eight
INTERNAL RCC Added rate for Each additional 0.5 meter depth exceeding
219 1.c Cum 70.000 198.001 Ninety- 13860.070 Hundred
ROAD (CIVIL 1.5 meter to 2.0 meter Depth
Eight point and Sixty
WORKS)
Zero Zero point Zero
One Seven
Two Fifteen
Hundred Thousand
PART-D-i :
and Nine
INTERNAL RCC Added rate for Each additional 0.5 meter depth exceeding
220 1.d Cum 70.000 228.001 Twenty- 15960.070 Hundred
ROAD (CIVIL 2.0 meter to 2.5 meter Depth
Eight point and Sixty
WORKS)
Zero Zero point Zero
One Seven
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 24/80
3/11/24, 2:55 PM View Form
Four Fifty-Six
Hundred Thousand
PART-D-i :
and Eight
INTERNAL RCC Bailing out of trapped water caused by inundation or rain, by
221 2 Hour 120.000 474.001 Seventy- 56880.120 Hundred
ROAD (CIVIL pump from foundation trenches.
Four point and Eighty
WORKS)
Zero Zero point One
One Two
Eighty-Six
Supplying of straight and strong borrak bamboo posts of
PART-D-i : Thousand
having minimum 75 mm diameter althrough and driving the Ninety
INTERNAL RCC Four
222 3 same vertically in the ground up to required depth by any Meter 960.000 90.001 point Zero 86400.960
ROAD (CIVIL Hundred
means shaping the top of the post, all complete and Zero One
WORKS) point Nine
accepted by the Engineer-in-charge.
Six
One Lakh
Palisading work by supplying of bitumen drum sheet walling Six
Forty-Four
PART-D-i : tied with 20 BWG G.I. wire fixing the same with already Hundred
Thousand
INTERNAL RCC driven borrak bamboo posts with half split borrak bamboo and
223 4 Sqm 235.000 613.001 144055.235 AND Fifty-
ROAD (CIVIL runners @ 450mm c/c horizontally with iron nails, G.I wire Thirteen
Five point
WORKS) etc. all complete and accepted by the Engineer-in-charge. point Zero
Two Three
(Rate is excluding the cost of bamboo post). Zero One
Five
One
Sand filling in foundation trenches and plinth with sand
Thousand Twenty-
having min. F.M. 1.2 in 150 mm in layers including leveling,
PART-D-i : Two Five Lakh
watering and compaction to achieve minimum dry density of
INTERNAL RCC Hundred Ninety-
224 5 95% with optimum moisture content (Modified proctor test) Cum 2000.000 1296.001 2592002.000
ROAD (CIVIL and Two
by ramming each layer up to finished level as per design
WORKS) Ninety-Six Thousand
supplied by the design office only, all complete and accepted
point Zero AND Two
by the Engineer-in-charge.
Zero One
Three
Lakh
Fourteen Thirty-
Thousand Three
PART-D-i : Five Thousand
INTERNAL RCC Hundred Seven
226 7 Dry Lean Concrete Class - 20 (concrete mixture). Cum 23.000 14512.001 333776.023
ROAD (CIVIL and Hundred
WORKS) Twelve and
point Zero Seventy-
Zero One Six point
Zero Two
Three
Thirty-Five
Brick works with first class bricks with cement sand (F.M. 1.2) Lakh
mortar (1:4) in exterior walls including filling the interstices Ten Eighty-
with mortar, raking out joints, cleaning and socking the bricks Thousand Four
PART-D-i :
at least for 24 hours before use and washing of sand, AND Thousand
INTERNAL RCC
227 8 necessary scaffolding, curing at least for 7 days etc. all Cum 355.000 10097.001 Ninety- 3584435.355 Four
ROAD (CIVIL
complete including cost of water, electricity and other Seven Hundred
WORKS)
charges (measurement to given as 250 mm width for one point Zero and Thirty-
brick length and 375 mm for one brick and a half brick length) Zero One Five point
accepted by the Engineer-in-charge. (Cement: CEM-II/B-M) Three Five
Five
One Lakh
Twenty-
Four
PART-D-i : Supplying and laying of single layer polythene sheet Forty- Thousand
INTERNAL RCC weighing one kilogram per 6.5 square meter in floor or any Seven Three
228 9 Sqm 2645.000 47.001 124317.645
ROAD (CIVIL where below cement concrete complete in all respect and point Zero Hundred
WORKS) accepted by Engineer-in-charge. Zero One and
Seventeen
point Six
Four Five
Seventy-
Sixteen
Seven
Thousand
Lakh Four
Nine
PART-D-i : Thousand
Hundred
INTERNAL RCC Cement Concrete Pavment (Concrete Class - 25) (concrete Eight
230 11 Cum 454.000 16971.001 and 7704834.454
ROAD (CIVIL mixture). Hundred
Seventy-
WORKS) and Thirty-
One point
Four point
Zero Zero
Four Five
One
Four
231 PART-D-i : 12 Testing work of concrete cylinder [From BUET (BRTC), Set 5.000 4875.001 Four 24375.005 Twenty-
INTERNAL RCC KUET (CRTS), RUET (DCE), SUST (CRTC) & DUET (DCE)] Thousand Four
ROAD (CIVIL size 150mm dia and 300mm hight for testing compressive Eight Thousand
WORKS) strength in the laboratory approved by the Engineer including Hundred Three
making cylinder using steel mould, curing the cylinder to the and Hundred
laboratory payment of the testing fees etc. complete as per Seventy- and
direction of the Engineer in charge. (Payment should be Five point Seventy-
made for the cylinders tested whoes strenght attain the Zero Zero Five point
specified strength of the concrete.) One
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 25/80
3/11/24, 2:55 PM View Form
Zero Zero
Five
One Lakh
Providing painting at the top of the road surface as road
Ninety-
marking in two coats with approved best quality and colour of
Three Four
Thermo-plastic paint, approved quality of paint from
Hundred Thousand
PART-D-i : authorized local agent of the manufacturer in a sealed
and Seven
INTERNAL RCC container having high water resistance, high bondability &
233 14 Sqm 525.000 371.001 Seventy- 194775.525 Hundred
ROAD (CIVIL flexibility, using specific brand thinner applied by brass/ roller
One point and
WORKS) or others over a coat of priming, providing elapsing time for
Zero Zero Seventy-
drying including surface cleaning from dust, oil or dirt,
One Five point
smoothening, finishing necessary tools etc. all complete &
Five Two
approved and accepted by the Engineer-in-charge.
Five
Rule pointing to brick wall with cement sand (F.M. 1.2) mortar
Two Eighty
PART-D-i : (1:2) with fresh cement and raking out the joints, curing at
Hundred Thousand
INTERNAL RCC least for 7 days, cost of water, electricity, scaffolding and
236 17 Sqm 400.000 201.001 and One 80400.400 Four
ROAD (CIVIL other charges etc. all complete in all respect as per drawing
point Zero Hundred
WORKS) and accepted by the Engineer-in-charge. (Cement: CEM-II/B-
Zero One point Four
M)
Eight Lakh
Flush pointing to brick wall with cement sand (F.M. 1.2)
Four Fourteen
PART-D-i : mortar (1:2) with cement including raking out the joints,
Hundred Thousand
INTERNAL RCC curing at least for 7 days, cost of water, electricity, scaffolding
237 18 Sqm 2025.000 402.001 and Two 814052.025 AND Fifty-
ROAD (CIVIL and other charges etc. all complete in all respect as per
point Zero Two point
WORKS) drawing and accepted by the Engineer-in-charge. (Cement:
Zero One Zero Two
CEM-II/B-M)
Five
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 26/80
3/11/24, 2:55 PM View Form
Two Lakh
Forty-
Three Eight
''Labour cost for making moulding in marble stone as per
Hundred Thousand
PART-D-i : architectural drawing including cutting, grinding, finishing,
and One
INTERNAL RCC supplying necessary equipment etc. complete in all respect
240 21 Rm 622.000 399.001 Ninety- 248178.622 Hundred
ROAD (CIVIL and accepted by the Engineer in Charge. (Cement: CEM-
Nine point and
WORKS) II/B-M)
Zero Zero Seventy-
12 mm thick marble stone''
One Eight point
Six Two
Two
Supplying, laying, fitting & fixing best quality 300 mm dia Two One Lakh
(internal) machine made R.C.C. pipe over 100 mm thick Thousand Thirty-
PART-D-i : cement concrete (1:3:6) at base and sides including single Three Eight
INTERNAL RCC brick flat soling and gasket with cement mortar (1:4) joints, Hundred Thousand
242 23 Rm 60.000 2315.001 138900.060
ROAD (CIVIL cutting and filling trenches up to required depth including and Nine
WORKS) excavation of soil etc. all complete in all respect as per type Fifteen Hundred
plan and accepted by the Engineer-in-charge (average depth point Zero point Zero
of trench is 1050 mm). (Cement: CEM-II/B-M) Zero One Six
247 PART-E-i : 3.b Earthwork in excavation in foundation trenches up to 1.5 m cum 2120.000 168.001 One 356162.120 Three
INTERNAL depth and maximum 10 m lead Hundred Lakh Fifty-
DRAINAGE, WALK and Sixty- Six
WAY & UTILITY Eight point Thousand
DUCT (CIVIL Zero Zero One
WORKS) One Hundred
and Sixty-
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 27/80
3/11/24, 2:55 PM View Form
Two point
One Two
One Thirty-Five
PART-E-i :
Hundred Thousand
INTERNAL
and Six
DRAINAGE, WALK Added rate for each additional 0.5 meter depth exceeding 1.5
248 3.c cum 180.000 198.001 Ninety- 35640.180 Hundred
WAY & UTILITY meter to 2.0 meter Depth
Eight point and Forty
DUCT (CIVIL
Zero Zero point One
WORKS)
One Eight
Thirty-
Four
PART-E-i : Three
Hundred
INTERNAL Thousand
and
DRAINAGE, WALK Bailing out of trapped water caused by inundation or rain, by One
249 4 hour 70.000 474.001 Seventy- 33180.070
WAY & UTILITY pump from foundation trenches. Hundred
Four point
DUCT (CIVIL and Eighty
Zero Zero
WORKS) point Zero
One
Seven
One Fifty-Four
Sand filling in foundation trenches and plinth with sand
PART-E-i : Thousand Thousand
having min. F.M. 1.2 in 150 mm in layers including leveling,
INTERNAL Two Four
watering and compaction to achieve minimum dry density of
DRAINAGE, WALK Hundred Hundred
250 5 95% with optimum moisture content (Modified proctor test) cum 42.000 1296.001 54432.042
WAY & UTILITY and and Thirty-
by ramming each layer up to finished level as per design
DUCT (CIVIL Ninety-Six Two point
supplied by the design office only, all complete and accepted
WORKS) point Zero Zero Four
by the Engineer-in-charge.
Zero One Two
One Lakh
Sixty-
Earth filling in foundation trenches and plinth in 150 mm layer
PART-E-i : Seven
with earth available within 90 m of the building site to achive Two
INTERNAL Thousand
minimum dry density of 95% with optimum moisture content Hundred
DRAINAGE, WALK Six
251 6 (Modified proctor test) including carrying watering, leveling, cum 810.000 207.001 and Seven 167670.810
WAY & UTILITY Hundred
dressing and compacting to a specified percentage each point Zero
DUCT (CIVIL and
layer up to finished level etc. all complete and accepted by Zero One
WORKS) Seventy
Engineer-in-charge.
point Eight
One
Seven
Lakh
Three
Compacted cement sand filling in foundation trenches and Thirty-
Thousand
PART-E-i : plinth with cement and coarse sand having min. F.M. 1.2 mix Four
One
INTERNAL ratio (1:15) in 150 mm in layers including leveling, watering Thousand
Hundred
DRAINAGE, WALK and compaction to achieve minimum dry density of 95% with Three
252 7 cum 235.000 3125.001 and 734375.235
WAY & UTILITY optimum moisture content (Modified proctor test) by ramming Hundred
Twenty-
DUCT (CIVIL each layer up to finished level as per design supplied by the and
Five point
WORKS) design office only etc. all complete and accepted by the Seventy-
Zero Zero
Engineer-in-charge. (Cement: CEM-II/B-M) Five point
One
Two Three
Five
Nine Lakh
Twenty-
PART-E-i : Six
Eight
INTERNAL One layer brick flat soling in foundation or in floor with first Hundred
Thousand
DRAINAGE, WALK class/picked jhama bricks (BDS 208) including preparation of and Thirty-
253 8 Sqm 1460.000 636.001 928561.460 Five
WAY & UTILITY bed and filling the interstices with local sand, leveling etc. Six point
Hundred
DUCT (CIVIL complete and accepted by the Engineer-in-charge. Zero Zero
and Sixty-
WORKS) One
One point
Four Six
One Lakh
Twenty-
PART-E-i : Flush pointing to brick wall with cement sand (F.M. 1.2)
Two Two
INTERNAL mortar (1:2) with cement including raking out the joints,
Hundred Thousand
DRAINAGE, WALK curing at least for 7 days, cost of water, electricity, scaffolding
255 10 Sqm 610.000 201.001 and One 122610.610 Six
WAY & UTILITY and other charges etc. all complete in all respect as per
point Zero Hundred
DUCT (CIVIL drawing and accepted by the Engineer-in-charge. (Cement:
Zero One and Ten
WORKS) CEM-II/B-M)
point Six
One
125 mm brick works with first class bricks with cement sand Six Lakh
One
PART-E-i : (F.M. 1.2) mortar (1:4) and making bond with connected walls Five
Thousand
INTERNAL including necessary scaffolding, raking out joints, cleaning Thousand
Four
DRAINAGE, WALK and soaking the bricks for at least 24 hours before use and Four
257 12 Sqm 430.000 1408.001 Hundred 605440.430
WAY & UTILITY washing of sand, curing at least for 7 days in all floors Hundred
and Eight
DUCT (CIVIL including cost of water, electricity and other charges etc. all and Forty
point Zero
WORKS) complete and accepted by the Engineer-in-charge. (Cement: point Four
Zero One
CEM-II/B-M) Three
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 28/80
3/11/24, 2:55 PM View Form
''Reinforced cement concrete works with minimum cement
content relates to mix ratio 1:1.5:3 having maximum water
cement ratio = 0.40 and minimum f'cr = 33.5 MPa, satisfying
a specified compressive strength f?c = 25 MPa at 28 days on
standard cylinders as per standard practice of Code
ACI/BNBC/ASTM, Cement conforming to BDS EN-197-1-
CEM-I, 52.5N (52.5 MPa) / ASTM-C 150 Type ? I, best
quality Sylhet sand or coarse sand of equivalent F.M. 2.2 and
20 mm down well graded stone chips conforming to ASTM C-
PART-E-i : 33 (Aggregate grading as per table shown in technical Thirty-
INTERNAL specification), conducting necessary tests, making and Twenty Three
DRAINAGE, WALK placing shutter in position and maintaining true to plumb, Thousand Lakh Forty
258 13.(a-1) Cum 167.000 20000.001 3340000.167
WAY & UTILITY making shutter water-tight properly, placing reinforcement in point Zero Thousand
DUCT (CIVIL position; mixing with standard mixer machine with hopper, Zero One point One
WORKS) fed by standard measuring boxes, casting in forms, Six Seven
compacting by vibrator machine and curing at least for 28
days, removing centering-shuttering after specified time
approved; including cost of water, electricity, other charges
etc. all complete, approved and accepted by the Engineer-in-
charge. (Rate is excluding laboratory test fees, the cost of
reinforcement and its fabrication, placing, binding etc. and
the cost of shuttering & centering)
a) Drain Base/ Footing
1) Casting''
One Lakh
''2) FORM WORK (Steel) Centering and shuttering, including Five
PART-E-i : Thirty
strutting, propping etc. (The formwork must be rigid enough Hundred
INTERNAL Thousand
both in and out of plane, to make the concrete surface true to and
DRAINAGE, WALK Nine
259 13.(a-2) the designed shape and size by using necessary MS sheets Sqm 225.000 582.001 Eighty- 130950.225
WAY & UTILITY Hundred
of minimum 16 BWG, angles of minimum size 40 mm x 40 Two point
DUCT (CIVIL and Fifty
mm x 5 mm, flat bars etc.) and removal of form for: Zero Zero
WORKS) point Two
Drain Base/ Footing '' One
Two Five
Fifty-Two
PART-E-i : Nineteen Lakh
INTERNAL Thousand Forty-Five
DRAINAGE, WALK ''Drain Wall/ RCC Wall Five Thousand
260 13.(b-1) Cum 269.000 19500.001 5245500.269
WAY & UTILITY 1) Casting '' Hundred Five
DUCT (CIVIL point Zero Hundred
WORKS) Zero One point Two
Six Nine
Twenty-
Six Lakh
Five
PART-E-i : Fifteen
Hundred
INTERNAL Thousand
and
DRAINAGE, WALK ''2) Form Work/Shuttering (steel) Two
261 13.(b-2) Sqm 5010.000 522.001 Twenty- 2615225.010
WAY & UTILITY '' Hundred
Two point
DUCT (CIVIL and
Zero Zero
WORKS) Twenty-
One
Five point
Zero One
PART-E-i :
Seven
INTERNAL Nineteen
Lakh Sixty
DRAINAGE, WALK ''PL level Slab Thousand
262 13.(c-1) Cum 40.000 19000.001 760000.040 Thousand
WAY & UTILITY 1) Casting '' point Zero
point Zero
DUCT (CIVIL Zero One
Four
WORKS)
Eighteen
Five Thousand
PART-E-i :
Hundred Seven
INTERNAL
and Hundred
DRAINAGE, WALK
263 13.(c-2) 2) Form Work/ Shuttering (steel) Sqm 32.000 587.001 Eighty- 18784.032 and
WAY & UTILITY
Seven Eighty-
DUCT (CIVIL
point Zero Four point
WORKS)
Zero One Zero
Three Two
Fifteen
PART-E-i : Lakh
INTERNAL Nineteen Seventy-
DRAINAGE, WALK ''Drain Top Slab Thousand Seven
264 13.(d-1) Cum 83.000 19000.001 1577000.083
WAY & UTILITY 1) Casting '' point Zero Thousand
DUCT (CIVIL Zero One point Zero
WORKS) Eight
Three
Five Lakh
Five Forty-Six
PART-E-i :
Hundred Thousand
INTERNAL
and Two
DRAINAGE, WALK
265 13.(d-2) 2) Form Work/ Shuttering (steel) Sqm 915.000 597.001 Ninety- 546255.915 Hundred
WAY & UTILITY
Seven and Fifty-
DUCT (CIVIL
point Zero Five point
WORKS)
Zero One Nine One
Five
267 PART-E-i : 15 ''Supplying, fabrication and fixing to detail as per design : Ton 48.000 122000.001 One Lakh 5856000.048 Fifty-Eight
INTERNAL ribbed or deformed bar reinforcement (excluding laboratory Twenty- Lakh Fifty-
DRAINAGE, WALK test fees) for Reinforced concrete, produced and marked in Two Six
WAY & UTILITY accordance with BDS ISO 6935-2:2016 (or standard Thousand Thousand
DUCT (CIVIL subsequently released from BSTI) including straightening point Zero point Zero
WORKS) and cleaning rust, if any, bending and binding in position with Zero One Four Eight
supply of G.I. wires,conducting necessary laboratory tests
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 29/80
3/11/24, 2:55 PM View Form
etc. (excluding splices or laps) complete in all respect and
accepted by the Engineer-in-charge (Measurement shall be
recorded only on standard mass per unit length of bars, while
dia of bars exceeds its standard)
Grade 400 (B400DWR / B420DWR: complying BDS ISO
6935-2:2016 / ASTM A615) ribbed or deformed bar produced
and marked according to Bangladesh standard, with
minimum yield strength, fy (ReH)= 400 MPa but fy not
exceeding 480 MPa and whatever is the actual yield strength
within allowable limit as per BNBC/ ACI 318, the ratio of
ultimate tensile strength fu to yield strength fy, shall be at
least 1.25 and minimum elongation after fracture and
minimum total elongation at maximum force is 17% and 8%
respectively: a) Ground floor''
Seven
Lakh
Minimum 12 mm thick cement sand (F.M. 1.2) plaster with Three
PART-E-i : Seventy-
neat cement finishing to plinth wall with cement (1:4) up to Hundred
INTERNAL Seven
150 mm below ground level including washing of sand, and
DRAINAGE, WALK Thousand
268 16 finishing the edges and corners and curing at least for 7 sqm 2040.000 381.001 Eighty- 777242.040
WAY & UTILITY Two
days, cost of water, electricity, scaffolding and other charges One point
DUCT (CIVIL Hundred
etc. all complete in all respect as per drawing and accepted Zero Zero
WORKS) and Forty-
by the Engineer-in-charge. (Cement: CEM-II/B-M) One
Two point
Zero Four
Supplying, laying, fitting & fixing best quality 300 mm dia Two
Sixty-Nine
PART-E-ii : (internal) machine made R.C.C. pipe over 100 mm thick Thousand
Thousand
INTERNAL cement concrete (1:3:6) at base and sides including single Three
Four
DRAINAGE, WALK brick flat soling and gasket with cement mortar (1:4) joints, Hundred
274 2 Rm 30.000 2315.001 69450.030 Hundred
WAY & UTILITY cutting and filling trenches up to required depth including and
and Fifty
DUCT (SANITARY excavation of soil etc. all complete in all respect as per type Fifteen
point Zero
WORKS) plan and accepted by the Engineer-in-charge (average depth point Zero
Three
of trench is 1050 mm).(Cement: CEM-II/B-M) Zero One
Seventy-
Supplying, laying, fitting and fixing best quality 900 mm dia Eleven
One
(internal) machine made R.C.C. pipe with socket over 100 Thousand
PART-E-ii : Thousand
mm thick cement concrete (1:3:6) at base and sides Nine
INTERNAL Eight
including single layer brick flat soling , cutting and filling Hundred
DRAINAGE, WALK Hundred
275 3 trenches up to required depth including excavation of soil etc. Rm 6.000 11979.001 and 71874.006
WAY & UTILITY and
complete in all respect as per type plan and accepted by the Seventy-
DUCT (SANITARY Seventy-
Engineer-in-charge (Cement: CEM-II/B-M) . [Rate is Nine point
WORKS) Four point
excluding cost of excavation, back-fill, materials for back-fill Zero Zero
Zero Zero
and bedding] One
Six
276 PART-E-ii : 4 ''Construction of non electric Eco STP of different sizes (as Each 1.000 683652.001 Six Lakh 683652.001 Six Lakh
INTERNAL per detail drawing attached in annexure) with 250 mm walls Eighty- Eighty-
DRAINAGE, WALK of brick work in cement mortar (1:4) having a brick flat soling Three Three
WAY & UTILITY and 125 mm thick reinforced cement concrete flooring (1:2:4) Thousand Thousand
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 30/80
3/11/24, 2:55 PM View Form
DUCT (SANITARY with 125 mm thick walls (1:4) in partition and flush pointing Six Six
WORKS) (1:2) on inside wall surface and 12 mm thick cement plaster Hundred Hundred
(1:4) with N.C.F. on floor and slab surface including and Fifty- and Fifty-
supplying, fitting and fixing of upvc pipes & Tees and Two point Two point
providing 450 mm dia water sealed heavy type C.I. manhole Zero Zero Zero Zero
cover with locking/unlocking arrangement and 100 mm thick One One
R.C.C (1:2:4) top slab, including centering, shuttering,
fabricating, casting and curing etc. complete up to required
depth including necessary earth work in excavation and
shoring, bailing out water and side filling, dressing, inside
cleaning, cow dung or old septic tank liquied for
charging/start up including the cost of all materials,
operations and incidental charges. etc. all complete as per
type plan approved and accepted by the Engineer-in-charge
(Rate is including cost of reinforcement and its fabrication,
binding and placing).
For 500 users''
Forty
PART-F-i : LAND
Leveling and dressing of lawn area to proper slope and Thousand
SCAPING & Eight point
grade by spading the same including supplying tools and Eight
281 PLANTATION 3 Sqm 5100.000 8.001 Zero Zero 40805.100
plants etc. all complete and accepted by the Engineer-in- Hundred
(ARBORICULTURE One
charge. and Five
WORKS)
point One
One Lakh
Thirty-Two
Nine Thousand
PART-F-i : LAND
Supply of best and approved quality alluvial loamy silty soil Hundred Three
SCAPING &
including loading, unloading at both ends, properly stacking and Hundred
282 PLANTATION 4 Cum 145.000 913.001 132385.145
at site including supply of tools and plants etc. all complete Thirteen and
(ARBORICULTURE
and accepted by the Engineer-in-charge. point Zero Eighty-
WORKS)
Zero One Five point
One Four
Five
Twenty-
One
Eight
PART-F-i : LAND Hundred
Labour charge for spreading the alluvial loamy silty soil from Thousand
SCAPING & and
the stacks at site on the lawn surface, leveling, dressing the One
283 PLANTATION 5 Cum 145.000 194.001 Ninety- 28130.145
same including supply all necessary tools and plants etc. all Hundred
(ARBORICULTURE Four point
complete and accepted by the Engineer-in-charge. and Thirty
WORKS) Zero Zero
point One
One
Four Five
Two Lakh
Spading for preparation of flower beds in pits up to 600 mm
Five Forty-Nine
PART-F-i : LAND depth, re-molding, picking up and placing and removing the
Hundred Thousand
SCAPING & spaded earth to a safe distance, mixing @ 1 cft well
and Sixty- Four
285 PLANTATION 7 decomposed cow dung with 20% loamy silty soil and 6 cft Sqm 440.000 567.001 249480.440
Seven Hundred
(ARBORICULTURE excavated soil and fill back the pit including supply of tools
point Zero and Eighty
WORKS) and plants, all complete and accepted by the Engineer-in-
Zero One point Four
charge.
Four
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 31/80
3/11/24, 2:55 PM View Form
One Lakh
Seventy-
Forty-Four
Two
Thousand
PART-F-i : LAND Thousand
Supply and carrying of 6.5 h.p., 550 mm blade 4 stroke, Eight
SCAPING & Four
finger trip 3 position height adjuster 200 mm x 38 mm star Hundred
286 PLANTATION 8 Each 2.000 72447.001 Hundred 144894.002
tread wheels grass cutting (Power Lawn Mower Machine): and
(ARBORICULTURE and Forty-
YARDMAN No. 060A Ninety-
WORKS) Seven
Four point
point Zero
Zero Zero
Zero One
Two
Two
PART-F-i : LAND Thousand
SCAPING & Plantation of Wedelia in campus by preparing bed with Eighteen One
288 PLANTATION 10 decomposed cow dung, providing suport etc. all complete Each 120.000 18.001 point Zero 2160.120 Hundred
(ARBORICULTURE and accepted by the Engineer-in-charge. Zero One and Sixty
WORKS) point One
Two
One
Thousand One Lakh
PART-F-i : LAND Two Twenty-
Plantation of Udal & Rain Tree (height of 6 rft to 8 rft), Palash
SCAPING & Hundred Two
& Kanakchura Tree (height of 5 rft to 7 rft) in campus by
290 PLANTATION 12 Each 100.000 1227.001 and 122700.100 Thousand
preparing bed with decomposed cow dung, providing suport
(ARBORICULTURE Twenty- Seven
etc. all complete and accepted by the Engineer-in-charge.
WORKS) Seven Hundred
point Zero point One
Zero One
One Ninety-
Thousand Eight
PART-F-i : LAND
Plantation of Pink Cassia (height of 6 rft to 8 rft) in campus Nine Thousand
SCAPING &
by preparing bed with decomposed cow dung, providing Hundred One
291 PLANTATION 13 Each 50.000 1963.001 98150.050
suport etc. all complete and accepted by the Engineer-in- and Sixty- Hundred
(ARBORICULTURE
charge. Three and Fifty
WORKS)
point Zero point Zero
Zero One Five
One
One Lakh
Thousand
PART-F-i : LAND Seventy-
Plantation of Krishnachura tree (height of 7 rft to 10 rft), Seven
SCAPING & One
Asian Palmyra Plam (height of 4 rft to 6 rft) in campus by Hundred
292 PLANTATION 14 Each 100.000 1718.001 171800.100 Thousand
preparing bed with decomposed cow dung, providing suport and
(ARBORICULTURE Eight
etc. all complete and accepted by the Engineer-in-charge. Eighteen
WORKS) Hundred
point Zero
point One
Zero One
One
Plantation of Shimul tree, Radhaachura (height of 5 rft to 7 Thousand One Lakh
PART-F-i : LAND rft), Sofeda tree (height of 4 rft to 6 rft), Kath Badam tree, Two Twenty-
SCAPING & Sonalu, Kadam tree, Chatim tree (height of 6 rft to 8 rft), Hundred Two
293 PLANTATION 15 Sofeda tree, Banana tree (height of 4 rft to 6 rft) in campus Each 100.000 1227.001 and 122700.100 Thousand
(ARBORICULTURE by preparing bed with decomposed cow dung, providing Twenty- Seven
WORKS) suport etc. all complete and accepted by the Engineer-in- Seven Hundred
charge. point Zero point One
Zero One
One
Thousand Eighty
PART-F-i : LAND Four Thousand
SCAPING & Plantation of Mango tree (height of 6 rft to 8 rft) in campus by Hundred Nine
294 PLANTATION 16 preparing bed with decomposed cow dung, providing suport Each 55.000 1472.001 and 80960.055 Hundred
(ARBORICULTURE etc. all complete and accepted by the Engineer-in-charge. Seventy- and Sixty
WORKS) Two point point Zero
Zero Zero Five Five
One
Sixty
One
Thousand
PART-F-i : LAND Thousand
Plantation of Kamranga tree (height of 4 rft to 6 rft), Bakul Seven
SCAPING & One
tree (height of 6 rft to 8 rft) in campus by preparing bed with Hundred
295 PLANTATION 17 Each 55.000 1104.001 Hundred 60720.055
decomposed cow dung, providing suport etc. all complete and
(ARBORICULTURE and Four
and accepted by the Engineer-in-charge. Twenty
WORKS) point Zero
point Zero
Zero One
Five Five
Nine
PART-F-i : LAND Hundred Fifty-Four
SCAPING & Plantation of Neem tree (height of 6 rft to 8 rft) in campus by and Thousand
296 PLANTATION 18 preparing bed with decomposed cow dung, providing suport Each 55.000 982.001 Eighty- 54010.055 AND Ten
(ARBORICULTURE etc. all complete and accepted by the Engineer-in-charge. Two point point Zero
WORKS) Zero Zero Five Five
One
Eighteen
Three
PART-F-i : LAND Thousand
Hundred
SCAPING & Plantation of Hasna Hena in campus by preparing bed with Two
and Thirty-
297 PLANTATION 19 decomposed cow dung, providing suport etc. all complete Each 55.000 331.001 18205.055 Hundred
One point
(ARBORICULTURE and accepted by the Engineer-in-charge. and Five
Zero Zero
WORKS) point Zero
One
Five Five
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 32/80
3/11/24, 2:55 PM View Form
Eighty-
Two
Eight
PART-F-i : LAND Thousand
Plantation of Coconut tree (height of 6 rft to 8 rft) in campus Thousand
SCAPING & Two
by preparing bed with decomposed cow dung, providing Three
298 PLANTATION 20 Each 40.000 2209.001 Hundred 88360.040
suport etc. all complete and accepted by the Engineer-in- Hundred
(ARBORICULTURE and Nine
charge. and Sixty
WORKS) point Zero
point Zero
Zero One
Four
Seventy-
One
Eight
Thousand
PART-F-i : LAND Thousand
Nine
SCAPING & Plantation of Kat Golap (height of 8 rft to 10 rft) in campus by Five
Hundred
299 PLANTATION 21 preparing bed with decomposed cow dung, providing suport Each 40.000 1963.001 78520.040 Hundred
and Sixty-
(ARBORICULTURE etc. all complete and accepted by the Engineer-in-charge. and
Three
WORKS) Twenty
point Zero
point Zero
Zero One
Four
Six
PART-F-ii : LAND Sixty-Six
Hundred
SCAPING & 1C-4x4 sqmm (NYY / 2XY) with 4 sqmm (BYA) ECC wire Thousand
and Sixty-
303 PLANTATION 3.2 through PVC pipe of minimum inner dia 30 mm having wall Rm 100.000 667.001 66700.100 Seven
Seven
(ELECTRICAL thickness of 1.9 mm Hundred
point Zero
WORKS) point One
Zero One
304 PART-F-ii : LAND 4.1 ''SURFACE WIRING (BYM) (THROUGH PVC CONDUIT): Rm 200.000 192.001 One 38400.200 Thirty-
SCAPING & Surface conduit wiring with the following PVC insulated and Hundred Eight
PLANTATION sheathed cable (BYM) & Green / Yellow bi-colour PVC and Thousand
(ELECTRICAL insulated ECC wire (BYA) through PVC conduit of reputed Ninety- Four
WORKS) manufacturer complete with 18 SWG GP sheet pull box with Two point Hundred
3 mm thick ebonite sheet cover, fixing materials, other Zero Zero point Two
accessories etc. as required including mending the damages One
good. All electrical contacts shall be of brass / copper
connected through connector or soldering (no twisting shall
be allowed) and cables shall be manufactured and tested
according to IEC / BS / VDE standards along with relevant,
BDS standard as per detailed specification mentioned in
Annexure-1. The work shall be carried out as per direction &
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 33/80
3/11/24, 2:55 PM View Form
approval of the Engineer In Charge. Cable manufacturer(s)
must have valid type test certificate (within last seven years)
from internationally accredited laboratory (like CPRI, KEMA
etc.) accepted / approved by the Engineer In Charge.
4.1) 1C-2x1.5 sqmm (BYM) cable with 1.5 sqmm (BYA) ECC
wire through PVC pipe of minimum inner dia 20 mm having
wall thickness of 1.5 mm''
Two Twenty-
PART-F-ii : LAND
Hundred Six
SCAPING & 1C-2x2.5sqmm (BYM) cable with 2.5 sqmm (BYA) ECC wire
and Sixty- Thousand
305 PLANTATION 4.2 through PVC pipe of minimum inner dia 25 mm having wall Rm 100.000 261.001 26100.100
One point One
(ELECTRICAL thickness of 1.7 mm
Zero Zero Hundred
WORKS)
One point One
Three
PART-F-ii : LAND Hundred Seven
SCAPING & and Hundred
309 PLANTATION 7.2 Two gang switch Each 2.000 375.001 Seventy- 750.002 and Fifty
(ELECTRICAL Five point point Zero
WORKS) Zero Zero Zero Two
One
One
Five
PART-F-ii : LAND Thousand
Hundred
SCAPING & AND
and
310 PLANTATION 7.3 Three gang switch Each 2.000 514.001 1028.002 Twenty-
Fourteen
(ELECTRICAL Eight point
point Zero
WORKS) Zero Zero
Zero One
Two
One
Thousand
Seven
PART-F-ii : LAND Five
Hundred
SCAPING & Hundred
and Sixty-
311 PLANTATION 7.4 Four gang switch Each 2.000 763.001 1526.002 and
Three
(ELECTRICAL Twenty-
point Zero
WORKS) Six point
Zero One
Zero Zero
Two
312 PART-F-ii : LAND 8 ''FLOOD LIGHT FITTINGS (LED):Supply & fixing LED flood Each 55.000 9350.001 Nine 514250.055 Five Lakh
SCAPING & light fittings of following specifications: Thousand Fourteen
PLANTATION Luminous efficacy: 100lm/w(minimum), Three Thousand
(ELECTRICAL Power Factor: minimum 0.95 Hundred Two
WORKS) Colour Rendering Index(Ra) :70≤Ra< 85 and Fifty Hundred
Driver: Should be of IEC standard such as point Zero and Fifty
MEANWELL/OSRAM/ENERGY+/SIGNIFY(PHILIPS) or Zero One point Zero
equivalent Five Five
LED chips :EPISTAR / OSRAM / SIGNIFY(PHILIPS) / CREE
/ BRIDGELUX or equivalent.
Colour temperature : 3500K-6500K (Warm-White)
Material: Aluminium Alloy Aluminium reflector, Heat proof
glass/Polycarbonate
Model & sample to be accepted / approved by the Engineer-
in-charge (with 2 years warranty). 100 W
Gloria Cat no-GLFL-902
Energy+ cat no-EPFDL-17001 (100 W)
Cosmo cat no-BDTCL-LFDL-02
Adex-AD FLE 100W830
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 34/80
3/11/24, 2:55 PM View Form
Asha cat No-ACS-LFL-2156- (100 w)
or equivalent.''
One
PART-F-ii : LAND Seven Thousand
SCAPING & Hundred Five
316 PLANTATION 11.b 16 Amps. Each 2.000 780.001 and Eighty 1560.002 Hundred
(ELECTRICAL point Zero and Sixty
WORKS) Zero One point Zero
Zero Two
One
PART-F-ii : LAND Seven Thousand
SCAPING & Hundred Five
317 PLANTATION 11.c 20 Amps. Each 2.000 780.001 and Eighty 1560.002 Hundred
(ELECTRICAL point Zero and Sixty
WORKS) Zero One point Zero
Zero Two
One
PART-F-ii : LAND Seven Thousand
SCAPING & Hundred Five
318 PLANTATION 11.d 25 Amps. Each 2.000 780.001 and Eighty 1560.002 Hundred
(ELECTRICAL point Zero and Sixty
WORKS) Zero One point Zero
Zero Two
''TPMCB : Providing & fixing on a prepared board 500 volt Four Four
PART-F-ii : LAND
grade following Triple pole miniature circuit Breaker (TPMCB) Thousand Thousand
SCAPING &
having minimum breaking capacity 6-KA /10 KA with thermal AND AND
319 PLANTATION 12 Each 1.000 4030.001 4030.001
over-current and instantaneous electromagnetic short circuit Thirty Thirty
(ELECTRICAL
release provision. point Zero point Zero
WORKS)
TPMCB accepted / approved by the engineer. a) 10 Amps.'' Zero One Zero One
''TPMCCB: Providing & fixing on a prepared board 500 volt Seven Seven
grade following triple-pole molded case circuit breaker Thousand Thousand
PART-F-ii : LAND
(TPMCCB) with thermal over-current and instantaneous Four Four
SCAPING &
electromagnetic short circuit release provision, manufactured Hundred Hundred
320 PLANTATION 13 Each 1.000 7466.001 7466.001
and tested in accordance with relevant IEC / VDE / NEMA / and Sixty- and Sixty-
(ELECTRICAL
BS / JIS standards. Six point Six point
WORKS)
TPMCCB accepted / approved by the engineer. a) 50 Amps. Zero Zero Zero Zero
(minimum 10-KA)'' One One
Two Two
''BUS - BAR: Providing and fixing 500 V 3-phase bus-bar
Thousand Thousand
PART-F-ii : LAND system assembled in prelaid board with porcelain insulators.
Five Five
SCAPING & There will be equal size holes on every bar at 0.5'''' interval
Hundred Hundred
321 PLANTATION 14 and bar to bar gap shall be 2'''' - 3''''. Each 1.000 2544.001 2544.001
and Forty- and Forty-
(ELECTRICAL a) 60 - 100 Amps. Copper flat bar (5 nos) : 4 nos 9''''
Four point Four point
WORKS) x1''''x3mm and 1 no 4''''x1''''x4mm for earthing mounted on
Zero Zero Zero Zero
insulator at both ends individually.''
One One
322 PART-F-ii : LAND 15 ''BOARD: Supplying and fixing of almirah type 18 SWG metal sqm 1.000 18780.001 Eighteen 18780.001 Eighteen
SCAPING & board of depth 228mm (6?) duly painted with powder coating Thousand Thousand
PLANTATION with epoxy polyester resin on all surfaces of board (gray / off- Seven Seven
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 35/80
3/11/24, 2:55 PM View Form
(ELECTRICAL white) having built in push type / suitable locking Hundred Hundred
WORKS) arrangement including metal bridges of suitable size for fixing and Eighty and Eighty
of all electrical control devices complete with suitable point Zero point Zero
anchoring arrangement in wall / column and keeping Zero One Zero One
provision for cable inlets and exits as required (only front
surface of the board will be considered for measurement).
(Manufactured by RECO / NASCO / C&S or equivalent
product of any other manufacturer) The front side of the
boards should be covered with required size tempered thick
fiber glass with rubber gaskets to observe the inside
arrangement. ''
Four
PART-F-ii : LAND
Ninety- Thousand
SCAPING &
c) Minimum inner dia 30 mm & minimum wall thickness 1.9 Two point Six
325 PLANTATION 16.c Rm 50.000 92.001 4600.050
mm. Zero Zero Hundred
(ELECTRICAL
One point Zero
WORKS)
Five
One
PART-G-i : 02-
Hundred Forty-Two
STORIED
Earthwork in excavation in foundation trenches up to 1.5 m and Sixty- Thousand
329 SECURITY 3.b Cum 250.000 168.001 42000.250
depth and maximum 10 m lead Eight point point Two
BUILDING (CIVIL
Zero Zero Five
WORKS)
One
One
Nine
PART-G-i : 02- Hundred
Thousand
STORIED and
Added rate for Each additional 0.5 meter depth exceeding Nine
330 SECURITY 3.c Cum 50.000 198.001 Ninety- 9900.050
1.5 meter to 2.0 meter Depth Hundred
BUILDING (CIVIL Eight point
point Zero
WORKS) Zero Zero
Five
One
Two
Eleven
PART-G-i : 02- Hundred
Thousand
STORIED and
Added rate for Each additional 0.5 meter depth exceeding Four
331 SECURITY 3.d Cum 50.000 228.001 Twenty- 11400.050
2.0 meter to 2.5 meter Depth Hundred
BUILDING (CIVIL Eight point
point Zero
WORKS) Zero Zero
Five
One
Two Twelve
PART-G-i : 02-
Hundred Thousand
STORIED
Added rate for Each additional 0.5 meter depth exceeding and Fifty- Nine
332 SECURITY 3.e Cum 50.000 258.001 12900.050
2.5 meter to 3.0 meter Depth Eight point Hundred
BUILDING (CIVIL
Zero Zero point Zero
WORKS)
One Five
333 PART-G-i : 02- 3.f Added rate for Each additional 0.5 meter depth exceeding Cum 50.000 288.001 Two 14400.050 Fourteen
STORIED 3.0 meter to 3.5 meter Depth Hundred Thousand
SECURITY and Four
Eighty- Hundred
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 36/80
3/11/24, 2:55 PM View Form
BUILDING (CIVIL Eight point point Zero
WORKS) Zero Zero Five
One
Four Sixteen
PART-G-i : 02- Hundred Thousand
STORIED and Five
Bailing out of trapped water caused by inundation or rain, by
334 SECURITY 4 Hour 35.000 474.001 Seventy- 16590.035 Hundred
pump from foundation trenches.
BUILDING (CIVIL Four point and Ninety
WORKS) Zero Zero point Zero
One Three Five
Three
Seven
PART-G-i : 02- Thousand
Shore protection work during excavation in foundation Hundred
STORIED Five
trenches up to 1.5 m depth to protect loss due to damage of and
335 SECURITY 5 Sqm 5.000 712.001 3560.005 Hundred
property by palisading accepted by the Engineer-in-charge. Twelve
BUILDING (CIVIL and Sixty
[The rate is including the cost of vertical post] point Zero
WORKS) point Zero
Zero One
Zero Five
One Lakh
One Fifty-One
PART-G-i : 02- Thousand Thousand
Shore protection work during excavation in foundation
STORIED AND Eight
trenches beyond 1.5 m depth to protect loss due to damage
336 SECURITY 6 Sqm 145.000 1047.001 Forty- 151815.145 Hundred
of property by palisading accepted by the Engineer-in-
BUILDING (CIVIL Seven and
charge. [The rate is including the cost of vertical post]
WORKS) point Zero Fifteen
Zero One point One
Four Five
Two Lakh
One
Sand filling in foundation trenches and plinth with sand Thirty-
Thousand
PART-G-i : 02- having min. F.M. 1.2 in 150 mm in layers including leveling, Three
Two
STORIED watering and compaction to achieve minimum dry density of Thousand
Hundred
337 SECURITY 7 95% with optimum moisture content (Modified proctor test) Cum 180.000 1296.001 233280.180 Two
and
BUILDING (CIVIL by ramming Each layer up to finished level as per design Hundred
Ninety-Six
WORKS) supplied by the design office only, all complete and accepted and Eighty
point Zero
by the Engineer-in-charge. point One
Zero One
Eight
Three
Compacted cement sand filling in foundation trenches and
Thousand Thirty-One
plinth with cement and coarse sand having min. F.M. 1.2 mix
PART-G-i : 02- One Thousand
ratio (1:15) in 150 mm in layers including leveling, watering
STORIED Hundred Two
and compaction to achieve minimum dry density of 95% with
338 SECURITY 8 Cum 10.000 3125.001 and 31250.010 Hundred
optimum moisture content (Modified proctor test) by ramming
BUILDING (CIVIL Twenty- and Fifty
each layer up to finished level as per design supplied by the
WORKS) Five point point Zero
design office only etc. all complete and accepted by the
Zero Zero One
Engineer-in-charge. (Cement: CEM-II/B-M)
One
One Lakh
Forty-
Seven Seven
PART-G-i : 02- Cleaning and disposing of excavated earth from the
Hundred Thousand
STORIED construction site by truck or by any other means to a place
and Fifty- Four
340 SECURITY 10 within 30 km radius of the city or town area including loading Cum 195.000 756.001 147420.195
Six point Hundred
BUILDING (CIVIL & unloading at both ends, leveling and dressing the carried
Zero Zero and
WORKS) earth etc. complete and accepted by the Engineer-in-charge.
One Twenty
point One
Nine Five
Two Lakh
Forty-Four
Six
PART-G-i : 02- Thousand
One layer brick flat soling in foundation or in floor with first Hundred
STORIED Eight
class/picked jhama bricks (BDS 208) including preparation of and Thirty-
341 SECURITY 11 Sqm 385.000 636.001 244860.385 Hundred
bed and filling the interstices with local sand, leveling etc. Six point
BUILDING (CIVIL and Sixty
complete and accepted by the Engineer-in-charge. Zero Zero
WORKS) point
One
Three
Eight Five
One Lakh
''Lean / blinding concrete (1:3:6) in foundation or in floor with Twenty-
Nine
cement, sand (F.M. 1.2) and picked jhama brick chips Six
Thousand
PART-G-i : 02- including breaking of chips, screening, mixing, laying, Thousand
Three
STORIED compacting to required level and curing for at least 7 days Three
Hundred
342 SECURITY 12 including the supply of water, electricity, costs of tools & Cum 13.500 9362.001 126387.014 Hundred
and Sixty-
BUILDING (CIVIL plants and other charges etc. all complete and accepted by and
Two point
WORKS) the Engineer-in-charge.(Cement: CEM-II/B-M) Eighty-
Zero Zero
a) Lean / blinding concrete in foundation (1:3:6) with cement, Seven
One
brick chips and sand of F.M. 1.2'' point Zero
One Four
Five
PART-G-i : 02- Thousand
Supplying and laying of single layer polythene sheet Forty-
STORIED Six
weighing one kilogram per 6.5 square meter in floor or any Seven
344 SECURITY 14 Sqm 120.000 47.001 5640.120 Hundred
where below cement concrete complete in all respect and point Zero
BUILDING (CIVIL and Forty
accepted by Engineer-in-charge. Zero One
WORKS) point One
Two
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 37/80
3/11/24, 2:55 PM View Form
Three
Brick works with first class bricks with cement sand (F.M. 1.2) Nine
Lakh
PART-G-i : 02- mortar (1:6) in foundation and plinth, filling the Thousand
Nineteen
STORIED joints/interstices fully with mortar, racking out the joints, One
Thousand
345 SECURITY 15 cleaning and soaking the bricks at least for 24 hours before Cum 35.000 9140.001 Hundred 319900.035
Nine
BUILDING (CIVIL use and curing at least for 7 days etc. all complete including and Forty
Hundred
WORKS) cost of water, electricity and other charges and accepted by point Zero
point Zero
the Engineer-in-charge. (Cement: CEM-II/B-M) Zero One
Three Five
''Brick works with first class bricks with cement sand (F.M.
Eight Lakh
1.2) mortar (1:4) in exterior walls including filling the
Ten Fifty-Eight
interstices with mortar, raking out joints, cleaning and socking
PART-G-i : 02- Thousand Thousand
the bricks at least for 24 hours before use and washing of
STORIED AND Two
sand, necessary scaffolding, curing at least for 7 days etc. all
346 SECURITY 16.i Cum 85.000 10097.001 Ninety- 858245.085 Hundred
complete including cost of water, electricity and other
BUILDING (CIVIL Seven and Forty-
charges (measurement to given as 250 mm width for one
WORKS) point Zero Five point
brick length and 375 mm for one brick and a half brick length)
Zero One Zero Eight
accepted by the Engineer-in-charge. (Cement: CEM-II/B-M)
Five
i) Ground floor''
Ten
Thousand
Four Lakh
PART-G-i : 02- Two
Eleven
STORIED Hundred
Thousand
347 SECURITY 16.ii ii) 1st floor Cum 40.000 10276.001 and 411040.040
AND Forty
BUILDING (CIVIL Seventy-
point Zero
WORKS) Six point
Four
Zero Zero
One
Seven
Ten
Lakh
Thousand
PART-G-i : 02- Thirty-One
Four
STORIED Thousand
Hundred
348 SECURITY 16.iii iii) 2nd floor/ Roof Top Cum 70.000 10455.001 731850.070 Eight
and Fifty-
BUILDING (CIVIL Hundred
Five point
WORKS) and Fifty
Zero Zero
point Zero
One
Seven
''125 mm brick works with first class bricks with cement sand
Seventy-
(F.M. 1.2) mortar (1:4) and making bond with connected walls One
Seven
PART-G-i : 02- including necessary scaffolding, raking out joints, cleaning Thousand
Thousand
STORIED and soaking the bricks for at least 24 hours before use and Four
Four
349 SECURITY 17.i washing of sand, curing at least for 7 days in all floors Sqm 55.000 1408.001 Hundred 77440.055
Hundred
BUILDING (CIVIL including cost of water, electricity and other charges etc. all and Eight
and Forty
WORKS) complete and accepted by the Engineer-in-charge. (Cement: point Zero
point Zero
CEM-II/B-M) Zero One
Five Five
i) Ground floor''
One Lakh
Ninety-
One
Three
Thousand
PART-G-i : 02- Thousand
Four
STORIED Nine
Hundred
350 SECURITY 17.ii ii) 1st floor Sqm 135.000 1437.001 193995.135 Hundred
and Thirty-
BUILDING (CIVIL and
Seven
WORKS) Ninety-
point Zero
Five point
Zero One
One Three
Five
One
Seven
Thousand
PART-G-i : 02- Thousand
Four
STORIED Three
Hundred
351 SECURITY 17.iii iii) 2nd floor/ Roof Top Sqm 5.000 1466.001 7330.005 Hundred
and Sixty-
BUILDING (CIVIL and Thirty
Six point
WORKS) point Zero
Zero Zero
Zero Five
One
Nine Lakh
Two Seventy-
Thousand Seven
PART-G-i : 02-
Nine Thousand
STORIED
Hundred Seven
353 SECURITY 18.ii ii) 1st floor Sqm 330.000 2963.001 977790.330
and Sixty- Hundred
BUILDING (CIVIL
Three and Ninety
WORKS)
point Zero point
Zero One Three
Three
Two
Fourteen
Thousand
Lakh
PART-G-i : 02- Nine
Eighty-
STORIED Hundred
One
354 SECURITY 18.iii iii) 2nd floor/ Roof Top Sqm 495.000 2992.001 and 1481040.495
Thousand
BUILDING (CIVIL Ninety-
AND Forty
WORKS) Two point
point Four
Zero Zero
Nine Five
One
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 38/80
3/11/24, 2:55 PM View Form
''Fancy screen work with different size hollow machine made
design blocks of uniform colour, carefully laid in cement sand
(F.M. 1.2) mortar (1:3) in all floors in wall with uniform mortar Sixty-
Four
joints, true to vertical and horizontal line including racking out Three
Thousand
PART-G-i : 02- joints, cleaning and soaking the blocks for minimum 24 hours Thousand
Five
STORIED before use including washing and screening of sand, Nine
Hundred
355 SECURITY 19.i scaffolding, curing etc. complete in all respect including Sqm 14.000 4568.001 63952.014 Hundred
and Sixty-
BUILDING (CIVIL supply of all necessary materials, cost of water, electricity and Fifty-
Eight point
WORKS) and other charges accepted by the Engineer-in-charge. Two point
Zero Zero
(Cement: CEM-II/B-M) Zero One
One
With design block size: 114 mm x 114 mm x 114 mm or Four
equivalent volume & design.
i) Ground floor''
Four
Ninety-
Thousand
One
PART-G-i : 02- Five
Thousand
STORIED Hundred
Nine
356 SECURITY 19.ii ii) 1st floor Sqm 20.000 4597.001 and 91940.020
Hundred
BUILDING (CIVIL Ninety-
and Forty
WORKS) Seven
point Zero
point Zero
Two
Zero One
Four
Thousand Sixty-Nine
PART-G-i : 02- Six Thousand
STORIED Hundred Three
357 SECURITY 19.iii iii) 2nd floor/ Roof Top Sqm 15.000 4626.001 and 69390.015 Hundred
BUILDING (CIVIL Twenty- and Ninety
WORKS) Six point point Zero
Zero Zero One Five
One
Forty-
Seven Three
PART-G-i : 02- Hundred Thousand
STORIED and Nine
359 SECURITY 20.ii iii) 2nd floor/ Roof Top Sqm 55.000 799.001 Ninety- 43945.055 Hundred
BUILDING (CIVIL Nine point and Forty-
WORKS) Zero Zero Five point
One Zero Five
Five
Two Lakh
Removing of spoils / mud accumulated during boring for cast
Seven Seventy-
PART-G-i : 02- in situ pile by wash boring from working site to a safe
Hundred Nine
STORIED distance by contractor's own arrangement i.e. with container
and Forty- Thousand
361 SECURITY 22 set in truck or on cart including loading, unloading everything Cum 375.000 744.001 279000.375
Four point point
BUILDING (CIVIL complete as per standard practice and accepted by the
Zero Zero Three
WORKS) Engineer-in-charge. (Quantity should be given three times of
One Seven
solid volume of boring)
Five
362 PART-G-i : 02- 23 Cast in situ pile with reinforced cement concrete works of Cum 125.000 19000.001 Nineteen 2375000.125 Twenty-
STORIED high slump by adding high range water reducing admixture Thousand Three
SECURITY (ASTM C494 Type A or F) with minimum cement content point Zero Lakh
BUILDING (CIVIL relates to mix ratio 1 : 1.5 : 3 having minimum f'cr = 26 Mpa, Zero One Seventy-
WORKS) and satisfying a specified compressive strength f?c = 21 Mpa Five
at 28 days on standard cylinders as per standard practice of Thousand
Code ACI/BNBC/ASTM & cement conforming to BDS EN- point One
197-1- CEM -1,52.5 N / ASTM-C 150 Type ? I, best quality Two Five
coarse sand [Sylhet sand or coarse sand of equivalent
F.M.2.2], 20 mm down well graded crushed stone chips
conforming to ASTM C-33, including breaking chips,
screening through proper sieves, making, placing re-bar
cage in position, placing and removing tri-pod as per
requirement, pouring the concrete in bore-hole with the help
of a tremie pipe, maintaining the tremie pipe immersed in
concrete by at least 1 meter throughout the period of
concreting, maintaining required slump, etc. mixing the
aggregates with standard mixer machine with hopper, casting
in forms, all complete including water, electricity, testing of
materials and concrete etc and other charges as per design,
drawing etc all complete approved and accepted by the
Engineer-in-charge. (Rate is excluding the cost of
reinforcement and its fabrication, binding, welding, placing
and admixture (approx doses 150 to 250 ml per bag of
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 39/80
3/11/24, 2:55 PM View Form
cement which is to be fixed upon consultation with design
office)
Eighty-
Providing and making point welding at contact point of the Two
PART-G-i : 02- spiral binders at reasonable intervals with the main Thousand
STORIED reinforcements by electric arc welding for construction of cast Four point Eight
363 SECURITY 24 in situ bored pile carefully with highly oxidized electrodes, Point 20700.000 4.001 Zero Zero 82820.700 Hundred
BUILDING (CIVIL making the points prominent and accepted by the Engineer- One and
WORKS) in-charge (Rate is inclusive of all materials labour, tools and Twenty
plants, electricity and all equipment). point
Seven
Sixty
Providing and making welded splice over two sides of
Four Thousand
contact by welding of minimum 300 mm length at the lap of
PART-G-i : 02- Hundred Three
main reinforcement in re-bar cage to be placed in bore-hole
STORIED and Hundred
where necessary by electric arc welding with highly oxidized
364 SECURITY 25 Rm 125.000 483.001 Eighty- 60375.125 and
electrodes making the joint prominent all complete and
BUILDING (CIVIL Three Seventy-
accepted by the Engineer-in-charge. (Rate is inclusive of all
WORKS) point Zero Five point
materials labour, tools and plants, electricity and all
Zero One One Two
equipment).
Five
Six Six
Thousand Thousand
PART-G-i : 02- Six Six
STORIED Hundred Hundred
Per set per
367 SECURITY 27.b b) Calibration of pressure gauge 1.000 6626.001 and 6626.001 and
site
BUILDING (CIVIL Twenty- Twenty-
WORKS) Six point Six point
Zero Zero Zero Zero
One One
Eighty- Eighty-
Nine Nine
PART-G-i : 02-
Thousand Thousand
STORIED
''c) For 50 tonne load, Per set per Eight Eight
368 SECURITY 27.c 1.000 89803.001 89803.001
i) For first test at one site for one testing set'' site Hundred Hundred
BUILDING (CIVIL
and Three and Three
WORKS)
point Zero point Zero
Zero One Zero One
One
PART-G-i : 02-
Thousand Thirty
STORIED ''d) For intermediate loading from 50 tonne to 100 tonne for
Two Thousand
369 SECURITY 27.d Each additional tonne. Tonne 25.000 1200.001 30000.025
Hundred point Zero
BUILDING (CIVIL i) For first test at one site for one testing set''
point Zero Two Five
WORKS)
Zero One
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 40/80
3/11/24, 2:55 PM View Form
One
Twenty-
Thousand
Nine
PART-G-i : 02- Four
Thousand
STORIED Hundred
b) For PIT test of Each additional pile after 12 (Twelve) pile Four
371 SECURITY 28.b Per Pile 20.000 1472.001 and 29440.020
tested at same site Hundred
BUILDING (CIVIL Seventy-
and Forty
WORKS) Two point
point Zero
Zero Zero
Two
One
Three
PART-G-i : 02-
Eighteen Lakh
STORIED
Thousand Ninety-Six
376 SECURITY 29.b.1.ii iii) 2nd floor/ Roof Top Cum 22.000 18000.001 396000.022
point Zero Thousand
BUILDING (CIVIL
Zero One point Zero
WORKS)
Two Two
Two Lakh
Five Thirty-
PART-G-i : 02- Hundred Seven
STORIED and Thousand
''2) Form Work/Shuttering (steel)
377 SECURITY 29.2.i Sqm 455.000 522.001 Twenty- 237510.455 Five
i) Ground floor''
BUILDING (CIVIL Two point Hundred
WORKS) Zero Zero and Ten
One point Four
Five Five
Sixty-Four
PART-G-i : 02- Five
Thousand
STORIED Hundred
Eight
378 SECURITY 29.2.ii ii) 1st floor Sqm 120.000 540.001 and Forty 64800.120
Hundred
BUILDING (CIVIL point Zero
point One
WORKS) Zero One
Two
One Lakh
Five Eight
PART-G-i : 02-
Hundred Thousand
STORIED
and Fifty- Eight
379 SECURITY 29.2.iiii iii) 2nd floor/ Roof Top Sqm 195.000 558.001 108810.195
Eight point Hundred
BUILDING (CIVIL
Zero Zero and Ten
WORKS)
One point One
Nine Five
380 PART-G-i : 02- 30.a.1 ''Reinforced cement concrete works with minimum cement Cum 22.000 17000.001 Seventeen 374000.022 Three
STORIED content relates to mix ratio 1:1.5:3 having maximum water Thousand Lakh
SECURITY cement ratio = 0.40 and minimum f'cr = 33.5 MPa, satisfying point Zero Seventy-
BUILDING (CIVIL a specified compressive strength f?c = 25 MPa at 28 days on Zero One Four
WORKS) standard cylinders as per standard practice of Code Thousand
ACI/BNBC/ASTM, Cement conforming to BDS EN-197-1- point Zero
CEM-I, 52.5N (52.5 MPa) / ASTM-C 150 Type ? I, best Two Two
quality Sylhet sand or coarse sand of equivalent F.M. 2.2 and
20 mm down well graded stone chips conforming to ASTM C-
33 (Aggregate grading as per table shown in technical
specification), conducting necessary tests, making and
placing shutter in position and maintaining true to plumb,
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 41/80
3/11/24, 2:55 PM View Form
making shutter water-tight properly, placing reinforcement in
position; mixing with standard mixer machine with hopper,
fed by standard measuring boxes, casting in forms,
compacting by vibrator machine and curing at least for 28
days, removing centering-shuttering after specified time
approved; including cost of water, electricity, other charges
etc. all complete, approved and accepted by the Engineer-in-
charge. (Rate is excluding laboratory test fees, the cost of
reinforcement and its fabrication, placing, binding etc. and
the cost of shuttering & centering)
a) Foundation Beam
1) Casting''
Ninety-
''2) Form Work/Shuttering (steel) Four Three
PART-G-i : 02- Centering and shuttering, including strutting, propping etc. Hundred Thousand
STORIED (The formwork must be rigid enough both in and out of plane, and Six
381 SECURITY 30.a.2 to make the concrete surface true to the designed shape and Sqm 190.000 493.001 Ninety- 93670.190 Hundred
BUILDING (CIVIL size by using necessary MS sheets of minimum 16 BWG, Three and
WORKS) angles of minimum size 40 mm x 40 mm x 5 mm, flat bars point Zero Seventy
etc.) and removal of form for: a) Foundation Beam'' Zero One point One
Nine
Five
Five
Thousand
PART-G-i : 02- Hundred
Eight
STORIED and
Hundred
383 SECURITY 30.b.2 2) Form Work/Shuttering (steel) Sqm 10.000 587.001 Eighty- 5870.010
and
BUILDING (CIVIL Seven
Seventy
WORKS) point Zero
point Zero
Zero One
One
Seventy-
PART-G-i : 02- Six
Seventeen
STORIED ''Stair case slab and steps Thousand
30.1.(e- Thousand
390 SECURITY 1) Casting Cum 4.500 17000.001 76500.005 Five
i) point Zero
BUILDING (CIVIL i) Ground floor'' Hundred
Zero One
WORKS) point Zero
Zero Five
Fifty-Nine
PART-G-i : 02-
Seventeen Thousand
STORIED
30.1.(e- Thousand Five
391 SECURITY ii) 1st floor Cum 3.500 17000.001 59500.004
ii) point Zero Hundred
BUILDING (CIVIL
Zero One point Zero
WORKS)
Zero Four
Twenty
Thousand
Five Three
PART-G-i : 02-
Hundred Hundred
STORIED ''2) Form Work/Shuttering (steel)
30.2.(e- and Fifty- and
392 SECURITY Stair case slab and steps Sqm 37.000 551.001 20387.037
i) One point Eighty-
BUILDING (CIVIL i) Ground floor ''
Zero Zero Seven
WORKS)
One point Zero
Three
Seven
Five Seventeen
PART-G-i : 02-
Hundred Thousand
STORIED
30.2.(e- and Sixty- AND
393 SECURITY ii) 1st floor Sqm 30.000 569.001 17070.030
ii) Nine point Seventy
BUILDING (CIVIL
Zero Zero point Zero
WORKS)
One Three
394 PART-G-i : 02- 31.(a-1) ''Reinforced cement concrete works from Ready-Mix Cum 46.000 18000.001 Eighteen 828000.046 Eight Lakh
STORIED concrete with minimum cement content relates to approved Thousand Twenty-
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 42/80
3/11/24, 2:55 PM View Form
SECURITY mix ratio having minimum f'cr = 40.5 MPa, satisfying a point Zero Eight
BUILDING (CIVIL specified compressive strength f?c = 32 MPa at 28 days on Zero One Thousand
WORKS) standard cylinders as per standard practice of Code ACI/ point Zero
BNBC/ ASTM,Cement conforming to BDS EN-197-1-CEM-I, Four Six
52.5N (52.5 MPa) / ASTM-C 150 Type ? I,best quality Sylhet
sand or coarse sand of equivalent F.M. 2.2 and 20 mm down
wellgraded stone chips conforming to ASTM C-33
(Aggregate grading as per table shown in technical
specification), High-range water reducing chemical admixture
Type-G under ASTM C494(Doses to be applied as per
Manufacturer's Guideline), conducting necessary tests,
making and placing shutter in position and maintaining true
to plumb, making shutter water-tight properly, placing
reinforcement in position; using machine batched and
machine mixed concrete using cement content as per
approved design mix (minimum 445 kg/ Cum), carrying to the
site of laying using Transit Mixer (considering Setting time of
concrete from plant to the site), including pumping of
concrete using line pump or boom placer to site of laying,
maintaining allowable slump of 100mm to150mm (measured
at site), casting in forms, compacting by vibrator machine
and curing at least for 28 days, removing centering-
shuttering after specified time approved; including cost of
water, electricity, cost of all materials and other charges etc.
all complete, approved and accepted by the Engineer-in-
charge. (Rate is excluding laboratory test fees, the cost of
reinforcement and its fabrication, placing, binding etc. and
the cost of shuttering & centering). (Foundation to 4th floor)
Note: The mix design shall be done from PWD testing
laboratory or other recognized laboratories and be consulted
with concerned design office.
a) Pile Cap/ Plinth level floor slab/ Ramp
1) Casting''
Forty-Two
''2) Form Work/Shuttering (steel)
Five Thousand
Centering and shuttering, including strutting, propping etc.
PART-G-i : 02- Hundred Two
(The formwork must be rigid enough both in and out of plane,
STORIED and Hundred
to make the concrete surface true to the designed shape and
395 SECURITY 31.(a-2) Sqm 72.000 587.001 Eighty- 42264.072 and Sixty-
size by using necessary MS sheets of minimum 16 BWG,
BUILDING (CIVIL Seven Four point
angles of minimum size 40 mm x 40 mm x 5 mm, flat bars
WORKS) point Zero Zero
etc.) and removal of form for:
Zero One Seven
a) Pile Cap/ Plinth level floor slab/ Ramp''
Two
Three
PART-G-i : 02-
Eighteen Lakh Six
STORIED ''Tee beam, L-beam and Rectangular beam
31.1.(b- Thousand Thousand
396 SECURITY 1) Casting Cum 17.000 18000.001 306000.017
i) point Zero point Zero
BUILDING (CIVIL i) Ground floor''
Zero One One
WORKS)
Seven
Two Lakh
PART-G-i : 02-
Eighteen Eighty-
STORIED
31.1.(b- Thousand Eight
397 SECURITY ii) 1st floor Cum 16.000 18000.001 288000.016
ii) point Zero Thousand
BUILDING (CIVIL
Zero One point Zero
WORKS)
One Six
PART-G-i : 02-
Eighteen Ninety
STORIED
31.1.(b- Thousand Thousand
398 SECURITY iii) 2nd floor/ Roof Top Cum 5.000 18000.001 90000.005
iii) point Zero point Zero
BUILDING (CIVIL
Zero One Zero Five
WORKS)
Eighty-
Five
''2) Form Work/Shuttering (steel)
Six Thousand
PART-G-i : 02- Added rate for additional height in centering, shuttering
Hundred One
STORIED where ever required with adequate bracing, propping etc.
31.2.(b- and Thirty- Hundred
399 SECURITY over a height of 4.0 m, for every additional height of 1 meter Sqm 135.000 631.001 85185.135
i) One point and
BUILDING (CIVIL or part thereof. (only for Gr. floor)
Zero Zero Eighty-
WORKS) Tee beam, L-beam and Rectangular beam
One Five point
i) Ground floor ''
One Three
Five
Five
Seventy-
PART-G-i : 02- Hundred
One
STORIED and
31.2.(b- Thousand
400 SECURITY ii) 1st floor Sqm 120.000 592.001 Ninety- 71040.120
ii) AND Forty
BUILDING (CIVIL Two point
point One
WORKS) Zero Zero
Two
One
Twenty-
One
PART-G-i : 02- Six
Thousand
STORIED Hundred
31.2.(b- Three
401 SECURITY iii) 2nd floor/ Roof Top Sqm 35.000 610.001 and Ten 21350.035
iii) Hundred
BUILDING (CIVIL point Zero
and Fifty
WORKS) Zero One
point Zero
Three Five
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 43/80
3/11/24, 2:55 PM View Form
Two Lakh
PART-G-i : 02-
Eighteen Thirty-
STORIED
31.1.(c- Thousand Four
404 SECURITY iii) 2nd floor/ Roof Top Cum 13.000 18000.001 234000.013
iii) point Zero Thousand
BUILDING (CIVIL
Zero One point Zero
WORKS)
One Three
Two Lakh
Twenty-
''2) Form Work/ Shuttering (steel)
Six Two
PART-G-i : 02- Added rate for additional height in centering, shuttering
Hundred Thousand
STORIED where ever required with adequate bracing, propping etc.
31.2.(c- and Fifty- Three
405 SECURITY over a height of 4.0 m, for every additional height of 1 meter Sqm 340.000 654.001 222360.340
i) Four point Hundred
BUILDING (CIVIL or part thereof. (only for Gr. floor)
Zero Zero and Sixty
WORKS) Floor/ Roof & Over head water reservoir Slab
One point
i) Ground floor ''
Three
Four
One Lakh
Eighty-
One
Six
PART-G-i : 02- Thousand
Hundred
STORIED Four
31.2.(c- and
406 SECURITY ii) 1st floor Sqm 295.000 615.001 181425.295 Hundred
ii) Fifteen
BUILDING (CIVIL and
point Zero
WORKS) Twenty-
Zero One
Five point
Two Nine
Five
Forty-Four
Six
PART-G-i : 02- Thousand
Hundred
STORIED Three
31.2.(c- and Thirty-
407 SECURITY iii) 2nd floor/ Roof Top Sqm 70.000 633.001 44310.070 Hundred
iii) Three
BUILDING (CIVIL and Ten
point Zero
WORKS) point Zero
Zero One
Seven
PART-G-i : 02-
Seventeen Sixty-Eight
STORIED
32.1.(a- Thousand Thousand
410 SECURITY iii) 2nd floor/ Roof Top Cum 4.000 17000.001 68000.004
iii) point Zero point Zero
BUILDING (CIVIL
Zero One Zero Four
WORKS)
Sixty-Four
Five Thousand
PART-G-i : 02-
Hundred Five
STORIED
32.2.(a- and Sixty- Hundred
412 SECURITY ii) 1st floor Sqm 115.000 561.001 64515.115
ii) One point and
BUILDING (CIVIL
Zero Zero Fifteen
WORKS)
One point One
One Five
Five Thirty
PART-G-i : 02- Hundred Thousand
STORIED and One
32.2.(a-
413 SECURITY iii) 2nd floor/ Roof Top Sqm 52.000 579.001 Seventy- 30108.052 Hundred
iii)
BUILDING (CIVIL Nine point and Eight
WORKS) Zero Zero point Zero
One Five Two
414 PART-G-i : 02- 32.1.(b- ''Cornice, false slab, railing, drop wall, fins, parapet etc. Cum 0.500 17000.001 Seventeen 8500.001 Eight
STORIED i) 1) Casting Thousand Thousand
SECURITY i) Ground floor '' point Zero Five
Zero One Hundred
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 44/80
3/11/24, 2:55 PM View Form
BUILDING (CIVIL point Zero
WORKS) Zero One
Two Lakh
PART-G-i : 02-
Seventeen Twenty-
STORIED
32.1.(b- Thousand One
416 SECURITY iii) 2nd floor/ Roof Top Cum 13.000 17000.001 221000.013
iii) point Zero Thousand
BUILDING (CIVIL
Zero One point Zero
WORKS)
One Three
Two
Five
PART-G-i : 02- Thousand
Hundred
STORIED ''2) Form Work/Shuttering (steel) Seven
32.2.(b- and Forty-
417 SECURITY Cornice, false slab, railing, drop wall, fins, parapet etc. Sqm 5.000 541.001 2705.005 Hundred
i) One point
BUILDING (CIVIL i) Ground floor'' and Five
Zero Zero
WORKS) point Zero
One
Zero Five
Eleven
Five Thousand
PART-G-i : 02-
Hundred Seven
STORIED
32.2.(b- and Fifty- Hundred
418 SECURITY ii) 1st floor Sqm 21.000 559.001 11739.021
ii) Nine point and Thirty-
BUILDING (CIVIL
Zero Zero Nine point
WORKS)
One Zero Two
One
One Lakh
Five
Nine
PART-G-i : 02- Hundred
Thousand
STORIED and
32.2.(b- Six
419 SECURITY iii) 2nd floor/ Roof Top Sqm 190.000 577.001 Seventy- 109630.190
iii) Hundred
BUILDING (CIVIL Seven
and Thirty
WORKS) point Zero
point One
Zero One
Nine
Three
PART-G-i : 02-
Twenty Lakh
STORIED
33.1.(a- Thousand Twenty
421 SECURITY ii) 1st floor Cum 16.000 20000.001 320000.016
ii) point Zero Thousand
BUILDING (CIVIL
Zero One point Zero
WORKS)
One Six
PART-G-i : 02-
Twenty Eighty
STORIED
33.1.(a- Thousand Thousand
422 SECURITY iii) 2nd floor/ Roof Top Cum 4.000 20000.001 80000.004
iii) point Zero point Zero
BUILDING (CIVIL
Zero One Zero Four
WORKS)
One
One Lakh
Thousand
Eighty
PART-G-i : 02- One
Thousand
STORIED Hundred
33.2.(a- Four
424 SECURITY ii) 1st floor Sqm 160.000 1128.001 and 180480.160
ii) Hundred
BUILDING (CIVIL Twenty-
and Eighty
WORKS) Eight point
point One
Zero Zero
Six
One
425 PART-G-i : 02- 33.2.(a- iii) 2nd floor/ Roof Top Sqm 34.000 1146.001 One 38964.034 Thirty-
STORIED iii) Thousand Eight
SECURITY One Thousand
BUILDING (CIVIL Hundred Nine
WORKS) and Forty- Hundred
Six point and Sixty-
Four point
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 45/80
3/11/24, 2:55 PM View Form
Zero Zero Zero
One Three
Four
Twenty-
Testing work of concrete cylinder [From BUET (BRTC), Four
Four
KUET (CRTS), RUET (DCE), SUST (CRTC) & DUET (DCE)] Thousand
Thousand
PART-G-i : 02- size 150mm dia and 300mm hight for testing compressive Eight
Three
STORIED strength in the laboratory approved by the Engineer including Hundred
Hundred
426 SECURITY 34 making cylinder using steel mould, curing the cylinder to the Set 5.000 4875.001 and 24375.005
and
BUILDING (CIVIL laboratory payment of the testing fees etc. complete as per Seventy-
Seventy-
WORKS) direction of the Engineer in charge. (Payment should be Five point
Five point
made for the cylinders tested whoes strenght attain the Zero Zero
Zero Zero
specified strength of the concrete.) One
Five
b) Laboratory Test for Reber [From BUET (BRTC), KUET Four Four
(CRTS), RUET (DCE), SUST (CRTC) & DUET (DCE)] of (i) Thousand Thousand
PART-G-i : 02- TENSILE STRENGTH TESTS : Yield Strength Ultimate Six Six
STORIED strength % Elongation etc. (ii) Bend. 1 Set of 3 samples. Hundred Hundred
428 SECURITY 35.b 4800 sft or less of PLA/ floor, Minimum 1 Set. additional Set Set 1.000 4625.001 and 4625.001 and
BUILDING (CIVIL for Each change in brand. In case of brand change, non Twenty- Twenty-
WORKS) compliance of test results etc. contractor will be liable for Five point Five point
additional tests and costs. Note : Test for Each diameter Zero Zero Zero Zero
rebar. One One
Twenty- Twenty-
c) Laboratory Test for COARSE AGGREGATE [From BUET
Three Three
PART-G-i : 02- (BRTC), KUET (CRTS), RUET (DCE), SUST (CRTC) &
Thousand Thousand
STORIED DUET (DCE)] of (i) Sieve Analysis, (ii) Unit Weight, (iii)
Two Two
429 SECURITY 35.c Absorption and Specific Gravity. 1 Set of 3 samples /3000 sft Set 1.000 23250.001 23250.001
Hundred Hundred
BUILDING (CIVIL or less of PLA/ Building Unit, Minimum 1 Set. In case of
and Fifty and Fifty
WORKS) brand change, non compliance of test results etc. contractor
point Zero point Zero
will be liable for additional tests and costs.
Zero One Zero One
Ten Ten
Thousand Thousand
d) Laboratory Test for FINE AGGREGATE [From BUET
PART-G-i : 02- Three Three
(BRTC), KUET (CRTS), RUET (DCE), SUST (CRTC) &
STORIED Hundred Hundred
DUET (DCE)] of (i) Sieve Analysis, (ii) Unit Weight. 1 Set of 3
430 SECURITY 35.d Set 1.000 10375.001 and 10375.001 and
samples/ 3000 sft or less of PLA. Minimum 1 Set. In case of
BUILDING (CIVIL Seventy- Seventy-
brand change, non compliance of test results etc. contractor
WORKS) Five point Five point
will be liable for additional tests and costs.
Zero Zero Zero Zero
One One
e) Laboratory Test for BRICKS [From BUET (BRTC), KUET Eighteen Eighteen
PART-G-i : 02- (CRTS), RUET (DCE), SUST (CRTC) & DUET (DCE)] of (i) Thousand Thousand
STORIED Crushing Strength, (ii) Water Absorption, (iii) Unit Weight, (iv) Two Two
431 SECURITY 35.e Size & Shape. 1 Set of 3 samples/ 2500 sft or less of PLA. Set 1.000 18250.001 Hundred 18250.001 Hundred
BUILDING (CIVIL Minimum 1 Set. In case of brand change, non compliance of and Fifty and Fifty
WORKS) test results etc. contractor will be liable for additional tests point Zero point Zero
and costs. Zero One Zero One
Eight Eight
Thousand Thousand
f) Laboratory Test for HOLLOW BRICKS [From BUET
PART-G-i : 02- Three Three
(BRTC), KUET (CRTS), RUET (DCE), SUST (CRTC) &
STORIED Hundred Hundred
DUET (DCE)] of (i) Absoprtion, (ii) Unit Weight. 1 Set of 3
432 SECURITY 35.f Set 1.000 8375.001 and 8375.001 and
samples/ 3000 sft or less of PLA. Minimum 1 Set. In case of
BUILDING (CIVIL Seventy- Seventy-
brand change, non compliance of test results etc. contractor
WORKS) Five point Five point
will be liable for additional tests and costs.
Zero Zero Zero Zero
One One
433 PART-G-i : 02- 36.(i) ''Supplying, fabrication and fixing to detail as per design : Ton 55.000 122000.001 One Lakh 6710000.055 Sixty-
STORIED ribbed or deformed bar reinforcement (excluding laboratory Twenty- Seven
SECURITY test fees) for Reinforced concrete, produced and marked in Two Lakh Ten
BUILDING (CIVIL accordance with BDS ISO 6935-2:2016 (or standard Thousand Thousand
WORKS) subsequently released from BSTI) including straightening point Zero point Zero
and cleaning rust, if any, bending and binding in position with Zero One Five Five
supply of G.I. wires,conducting necessary laboratory tests
etc. (excluding splices or laps) complete in all respect and
accepted by the Engineer-in-charge (Measurement shall be
recorded only on standard mass per unit length of bars, while
dia of bars exceeds its standard)
Grade 400 (B400DWR / B420DWR: complying BDS ISO
6935-2:2016 / ASTM A615) ribbed or deformed bar produced
and marked according to Bangladesh standard, with
minimum yield strength, fy (ReH)= 400 MPa but fy not
exceeding 480 MPa and whatever is the actual yield strength
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 46/80
3/11/24, 2:55 PM View Form
within allowable limit as per BNBC/ ACI 318, the ratio of
ultimate tensile strength fu to yield strength fy, shall be at
least 1.25 and minimum elongation after fracture and
minimum total elongation at maximum force is 17% and 8%
respectively:
i) Ground floor''
Twenty
One Lakh Lakh
PART-G-i : 02-
Twenty- Ninety-
STORIED
Three One
434 SECURITY 36.(ii) ii) 1st floor Ton 17.000 123000.001 2091000.017
Thousand Thousand
BUILDING (CIVIL
point Zero point Zero
WORKS)
Zero One One
Seven
Fourteen
One Lakh
PART-G-i : 02- Lakh
Twenty-
STORIED Eighty-
Four
435 SECURITY 36.(iii) iii) 2nd floor/ Roof Top Ton 12.000 124000.001 1488000.012 Eight
Thousand
BUILDING (CIVIL Thousand
point Zero
WORKS) point Zero
Zero One
One Two
Two
b) Supply and use of accelerating chemical admixture in One
PART-G-i : 02- Thousand
concrete, complying ASTM C-494 Type - C of approved Hundred
STORIED Nine
brand/origin/manufacturer and supplied by only and Forty-
437 SECURITY 37.b Liter 20.000 147.001 2940.020 Hundred
manufacturer's authorised dealer with certificate of origin. An Seven
BUILDING (CIVIL and Forty
admixture that is to accelerate the setting time and early point Zero
WORKS) point Zero
strength gain of concrete. Zero One
Two
Minimum 12 mm thick cement sand (F.M. 1.2) plaster with Three Four
PART-G-i : 02- neat cement finishing to dado with cement (1:4) up to 150 Hundred Thousand
STORIED mm including washing of sand, finishing the edges and and Seven
440 SECURITY 39 corners and curing at least for 7 days, cost of water, Sqm 12.000 395.001 Ninety- 4740.012 Hundred
BUILDING (CIVIL electricity, scaffolding and other charges etc. all complete in Five point and Forty
WORKS) all respect as per drawing and accepted by the Engineer-in- Zero Zero point Zero
charge. (Cement: CEM-II/B-M) i) Ground floor One One Two
442 PART-G-i : 02- 41.(i) Minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:4) Sqm 1185.000 315.001 Three 373276.185 Three
STORIED with fresh cement to both inner-and outer surface of wall, Hundred Lakh
SECURITY finishing the corner and edges including washing of sand, and Seventy-
BUILDING (CIVIL cleaning the surface, curing at least for 7 days, cost of water, Fifteen Three
WORKS) electricity, scaffolding and other charges etc. all complete in point Zero Thousand
all respect as per drawing and accepted by the Engineer-in- Zero One Two
charge. (Cement: CEM-II/B-M) i) Ground floor Hundred
and
Seventy-
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 47/80
3/11/24, 2:55 PM View Form
Six point
One Eight
Five
Two Lakh
Forty-
PART-G-i : 02- Three Seven
STORIED Hundred Thousand
443 SECURITY 41.(ii) ii) 1st floor Sqm 750.000 330.001 and Thirty 247500.750 Five
BUILDING (CIVIL point Zero Hundred
WORKS) Zero One point
Seven
Five
Two Lakh
Three Ten
PART-G-i : 02-
Hundred Thousand
STORIED
and Forty- Four
444 SECURITY 41.(iii) iii) 2nd floor/ Roof Top Sqm 610.000 345.001 210450.610
Five point Hundred
BUILDING (CIVIL
Zero Zero and Fifty
WORKS)
One point Six
One
Minimum 6 mm thick cement sand (F.M. 1.2) plaster (1:4) Two Lakh
with fresh cement to ceiling, R.C.C. columns, beams, surface Fifty-One
PART-G-i : 02- of stair case, sunshades, cornices, railings, drop wall, Three Thousand
STORIED louvers, fins and finishing the corners and edges including Hundred Three
445 SECURITY 42.(i) washing of sand, cleaning the surface, curing at least for 7 Sqm 835.000 301.001 and One 251335.835 Hundred
BUILDING (CIVIL days, cost of water, electricity, scaffolding and other charges point Zero and Thirty-
WORKS) etc. all complete in all respect as per drawing and accepted Zero One Five point
by the Engineer-in-charge. (Cement: CEM-II/B-M) i) Ground Eight
floor Three Five
Two Lakh
Forty
Three Thousand
PART-G-i : 02-
Hundred Nine
STORIED
and Hundred
446 SECURITY 42.(ii) ii) 1st floor Sqm 765.000 315.001 240975.765
Fifteen and
BUILDING (CIVIL
point Zero Seventy-
WORKS)
Zero One Five point
Seven Six
Five
One Lakh
Ninety-Six
Three
PART-G-i : 02- Thousand
Hundred
STORIED Nine
and Thirty-
447 SECURITY 42.(iii) iii) 2nd floor/ Roof Top Sqm 595.000 331.001 196945.595 Hundred
One point
BUILDING (CIVIL and Forty-
Zero Zero
WORKS) Five point
One
Five Nine
Five
Twenty-
Six
Seven
PART-G-i : 02- Hundred
Thousand
STORIED and
One
449 SECURITY 43.(ii) ii) 2nd floor/ Roof Top (O.H.W.R.) Sqm 40.000 679.001 Seventy- 27160.040
Hundred
BUILDING (CIVIL Nine point
and Sixty
WORKS) Zero Zero
point Zero
One
Four
451 PART-G-i : 02- 45.a ''Supply and use of best quality pliable, cold applied pre- Sqm 5.000 1085.001 One 5425.005 Five
STORIED formed self adhesive rubberized/ bituminous water proofing Thousand Thousand
SECURITY membrane of approved brand / origin / manufacturer from an AND Four
BUILDING (CIVIL authorized local agent or manufacturer having minimum Eighty- Hundred
WORKS) thickness 1.5 mm, lined with 2 ply cross laminated high Five point and
density polyethylene film performances and properties all Zero Zero Twenty-
conforming to ASTM standards and laying, placing, fixing on One Five point
made up firm and dry surfaces free from hollows, sharp Zero Zero
protrusions, contaminates etc. laid over-lap by at least 75 Five
mm along the edges and 125 mm at ends ensuring good
initial bond with the surfaces all complete under the strict
accordance with the manufacturer recommendations and
instructions providing all safety provisions in all respects and
accepted by the Engineer. (supplied by only manufacturer's
authorised dealer with certificate of origin) under following
specification:
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 48/80
3/11/24, 2:55 PM View Form
Backing(HDPE) thickness minimum 0.10mm
Membrane thickness minimum 1.40mm
Total thickness minimum 1.50mm
Cold flexibility greater than (-)200C: ASTM D146
Pliability: ''''No crack'''' tested in ASTM D146
Tensile strength (film only) min 3.50 MPa(35000kN/m2)
testing in ASTM D882
Tensile strength (composite) at least 2.40 MPa or N/mm2
Elongation (composite) min 300%
Cycling over crack at (-) 320C No effect 100 cycles ASTM
C836-89a
Puncture resistance greater than 240N ASTM E 154-88
Resistance to hydrostatic head at least 50m ASTM D5385
Tear resistance min 4.0 MPa (N/mm2)
Adhesion to primed concrete min 4.0 N/mm : ASTM D1000
Water vapor transmission Less than 0.10g/m2 per hour :
ASTM E96
Water absorption in 24 hour Less than 0.33% ASTM D570
Heat stability (+) 900C
Environmental complience to conform: ASTM D543
a) Water-proofing membrane on external surface of primed
vertical or inclined wall /on plastered and primed back-wall
and concrete cast against membrane. (Excluding cost of
back fill/brick wall on back/plaster when membrane laid on
back-wall and concrete cast against membrane which to be
paid as per corresponding items in this schedule)''
Four
Eight Thousand
b) Water-proofing membrane on made up surface below the
PART-G-i : 02- Hundred Four
floor or below the horizontal surfaces with temporary
STORIED and Hundred
protective cover using polystyrene/38 mm thick sand-cement
452 SECURITY 45.b Sqm 5.000 895.001 Ninety- 4475.005 and
mortar in 4:1 /or by equally effective alternative. (Rate is
BUILDING (CIVIL Five point Seventy-
excluding the cost of protective cover which to be paid as per
WORKS) Zero Zero Five point
corresponding items in this schedule)
One Zero Zero
Five
Sixty-Four
Thousand
Eight Two
PART-G-i : 02- Providing aluminium chanel to the nose of sunshade size of
Hundred Hundred
STORIED 19 mm x 19 mm x 19 mm and thickness of 1.2 mm including
and Thirty- and
453 SECURITY 46 groove cutting in plaster, fitting and fixing with bolts and Rm 77.000 835.001 64295.077
Five point Ninety-
BUILDING (CIVIL screws. cost of electricity and other charges all complete and
Zero Zero Five point
WORKS) accepted by the Engineer-in-charge.
One Zero
Seven
Seven
Four
PART-G-i : 02- Thousand
STORIED Making groove in plaster on outside wall upto 38 mm X 6 mm Forty-Five Nine
454 SECURITY 47 size including scaffolding, curing etc. complete as per Rm 110.000 45.001 point Zero 4950.110 Hundred
BUILDING (CIVIL drawing and accepted by the Engineer-in-charge. Zero One and Fifty
WORKS) point One
One
One Three
Thousand Lakh
PART-G-i : 02- Six Ninety
STORIED Hundred Thousand
457 SECURITY 49.(a-ii) ii) 1st floor Sqm 240.000 1626.001 and 390240.240 Two
BUILDING (CIVIL Twenty- Hundred
WORKS) Six point and Forty
Zero Zero point Two
One Four
One
Sixty-Five
Thousand
PART-G-i : 02- Thousand
Six
STORIED Six
Hundred
458 SECURITY 49.(a-iii) iii) 2nd floor/ Roof Top (Parapet Top) Sqm 40.000 1641.001 65640.040 Hundred
and Forty-
BUILDING (CIVIL and Forty
One point
WORKS) point Zero
Zero Zero
Four
One
One Forty-Six
Thousand Thousand
PART-G-i : 02-
Three Three
STORIED
''b) GP (homogeneous) 300 mm x 300 mm floor tiles Hundred Hundred
459 SECURITY 49.(b-i) Sqm 34.000 1362.001 46308.034
i) 1st Floor '' and Sixty- and Eight
BUILDING (CIVIL
Two point point Zero
WORKS)
Zero Zero Three
One Four
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 49/80
3/11/24, 2:55 PM View Form
''Supplying, fitting and fixing country made glazed wall tiles
Three
complying BDS ISO 13006: 2015, irrespective of color &/or One
Lakh
design, with 20 mm thick cement sand (F.M. 1.2) mortar (1:3) Thousand
Ninety-
PART-G-i : 02- base and raking out the joints with white cement including Eight
Five
STORIED cutting, laying and hire charge of machine and finishing with Hundred
Thousand
460 SECURITY 50.(i) care etc. including cost of water, electricity and other charges Sqm 210.000 1884.001 and 395640.210
Six
BUILDING (CIVIL complete in all respect and accepted by the Engineer-in- Eighty-
Hundred
WORKS) charge. (Cement: CEM-II/B-M) Four point
and Forty
Wall tiles more than 250 mm x 400 mm & less than or equal Zero Zero
point Two
to 300 mm x 600 mm in sizes, One
One
i) 1st floor''
Seventy-
One
Four
Thousand
Thousand
PART-G-i : 02- Seven
Six
STORIED Hundred
Hundred
462 SECURITY 51.(ii) ii) 1st floor Sqm 42.000 1778.001 and 74676.042
and
BUILDING (CIVIL Seventy-
Seventy-
WORKS) Eight point
Six point
Zero Zero
Zero Four
One
Two
Four Two
''Labour cost for making moulding in marble stone as per
PART-G-i : 02- Hundred Thousand
architectural drawing including cutting, grinding, finishing,
STORIED and Eight
supplying necessary equipment etc. complete in all respect
465 SECURITY 54.a Rm 6.000 475.001 Seventy- 2850.006 Hundred
and accepted by the Engineer in Charge. (Cement: CEM-
BUILDING (CIVIL Five point and Fifty
II/B-M).
WORKS) Zero Zero point Zero
a) 18 mm thick marble stone''
One Zero Six
One Lakh
Three Twenty-
PART-G-i : 02- Hundred Seven
STORIED and Thousand
b) 12 mm thick marble stone (For Stair and Parapet Top Tiles
466 SECURITY 54.b Rm 320.000 399.001 Ninety- 127680.320 Six
Moulding)
BUILDING (CIVIL Nine point Hundred
WORKS) Zero Zero and Eighty
One point
Three Two
Two Lakh
Forty-
Thirty-Five
Seven
PART-G-i : 02- Thousand
Thousand
STORIED Seven
b) Size greater than 0'-2.5'' x 0'-6'' and upto 0'-2.5'' x 0'-11'' One
468 SECURITY 55.b Cum 0.200 235719.001 Hundred 47143.800
(finished) Hundred
BUILDING (CIVIL and
and Forty-
WORKS) Nineteen
Three
point Zero
point Eight
Zero One
469 PART-G-i : 02- 56 ''Supplying, fitting and fixing of 38 mm thick well matured Sqm 25.000 13499.001 Thirteen 337475.025 Three
STORIED seasoned (moisture content should be between 12% to 16%) Thousand Lakh
SECURITY solid wood single leaf door shutter having stile section 100m Four Thirty-
x 38mm, top rail section 125mm x 38mm, lock rail section Hundred Seven
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 50/80
3/11/24, 2:55 PM View Form
BUILDING (CIVIL 100mm x 38mm and bottom rail section 225mm x 38mm and Thousand
WORKS) (made from minimum 250mm wide plank) with 4nos 100mm Ninety- Four
long, 3mm thick hinge, 12mm dia 250mm long tower bolt, Nine point Hundred
12mm dia 200mm long socket bolt, 2nos 150mm long Zero Zero and
handle, hinged cleats and buffer blocks. All complete in all One Seventy-
floors and accepted by the Engineer-in-charge. (All sizes of Five point
wood are finished) Zero Two
a) Chattogram Teak (SS Fittings)'' Five
474 PART-G-i : 02- 61 ''Supplying, fitting and fixing of aluminium sliding doors as Sqm 18.000 3794.001 Three 68292.018 Sixty-Eight
STORIED per the U.S. Architectural Aluminium Manufacturer's Thousand Thousand
SECURITY Association (AAMA) standard specification and BDS Seven Two
BUILDING (CIVIL 1879:2014 having minimum 1.2 mm thick outer bottom (size Hundred Hundred
WORKS) 75.50 mm, 17.79 mm, 0.47 kg/m), minimum 1.2 mm thick and and
outer top (size 75.50 mm, 28.50 mm, 0.705 kg/m) ,minimum Ninety- Ninety-
1.2 mm thick shutter top (size 33 mm, 26.80 mm, 0.42 kg/m), Four point Two point
minimum 1.2 mm shutter bottom (size 60 mm, 24 mm, 0.589 Zero Zero Zero One
kg/m), minimum 1.2 mm thick outer side(size 75.50 mm, One Eight
19.90 mm, 0.52 kg/m),minimum 1.2 mm thick shutter lock
(size 49.20 mm, 25.80 mm, 0.543 kg/m), minimum 1.2 mm
thick inter lock (size 34.40 mm, 32.13 mm, 0.562 kg/m)
sections all aluminum members will be anodized to
aluminium bronze/silver/ss/black colour with a coat not less
than 15 micrones in thickness or powder coated to any
colour with a coat not less than 25 micrones in thickness and
density of 4 mg per square cm etc. including all accessories
like handle, sliding door key lock , sliding door wheel, sliding
door mohiar, sliding door neoprene, bolts and nuts including
sealants, keeping provision for fitting 5/6 mm thick glass
including labour charge for fitting of accessories, making
grooves and mending good damages, carriage, and
electricity complete in all respect as per drawing and
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 51/80
3/11/24, 2:55 PM View Form
accepted by the Engineer-in-charge.
Size up to: 2100 mm x 2100 mm
Powder coated to any colour''
Three
Two
Lakh
Thousand
''Supplying, fitting and fixing in Aluminium door frames, Sixty-Eight
PART-G-i : 02- Eight
windows, partitions and curtain wall distortion free glass of Thousand
STORIED Hundred
approved quality and shade including cost of fitting fixing all Five
477 SECURITY 64.a Sqm 128.000 2879.001 and 368512.128
necessary accessories etc. complete in all respect as per Hundred
BUILDING (CIVIL Seventy-
drawing and accepted by the Engineer-in-charge. and
WORKS) Nine point
a) 6 mm thick clear tempered glass'' Twelve
Zero Zero
point One
One
Two Eight
One
Six
Thousand
PART-G-i : 02- Thousand
Two
STORIED AND
Hundred
478 SECURITY 64.b b) 5 mm thick ambushed glass Sqm 5.000 1215.001 6075.005 Seventy-
and
BUILDING (CIVIL Five point
Fifteen
WORKS) Zero Zero
point Zero
Five
Zero One
Forty
''Supplying, fitting and fixing of best quality of different dia Thousand
Six
PART-G-i : 02- foreign made aluminium pipe curtain rail for door and window Five
Hundred
STORIED including cutting and fitting-fixing as per required Hundred
and
480 SECURITY 66 measurement and supplying necessary screws, SS clamp, Rm 66.000 614.001 40524.066 and
Fourteen
BUILDING (CIVIL electric drill and rowel plug including charge of electricity etc. Twenty-
point Zero
WORKS) all complete and accepted by the Engineer-in-charge. Four point
Zero One
20 mm dia Aluminium pipe curtain rail'' Zero Six
Six
482 PART-G-i : 02- 67 Exterior premium acrylic emulsion paint of approved best Sqm 5.000 298.001 Two 1490.005 One
STORIED quality and color with high performance against dirt picking Hundred Thousand
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 52/80
3/11/24, 2:55 PM View Form
SECURITY tendency and efflorosence resistence properties along with and Four
BUILDING (CIVIL water resisting properties and resistance properties against Ninety- Hundred
WORKS) fungi, fading and flaking from authorized local agent of the Eight point and Ninety
manufacturer in a sealed container; applying to exterior Zero Zero point Zero
surface with surface preparation including cleaning drying, One Zero Five
making free from dirt, grease, wax, removing all chalked and
scaled materials, fungus, mending good the surface defects
using sand paper and necessary scaffolding; applying
necessary exterior sealer of specified brand on prepared
surface; then applying necessary exterior putty of specified
brand for levelling, spot filling, crack filling and cutting by
sand paper/zero water paper; finally applying 2 coats of
exterior emulsion paint spreading by brush/roller/spray &
necessary scaffolding etc. upto desired finishing, elapsing
specified time for drying or recoating; all complete in all floors
and accepted by the Engineer-in-charge.
Forty-Nine
Five
PART-G-i : 02- Premium French polishing to door and window frames, Thousand
Hundred
STORIED shutter and any other wooden surface by three coats over a Three
and
483 SECURITY 68 coat of priming including putty, cleaning, finishing and Sqm 95.000 519.001 49305.095 Hundred
Nineteen
BUILDING (CIVIL polishing with sand paper etc. all complete in all floors and and Five
point Zero
WORKS) accepted by the Engineer-in-charge. point Zero
Zero One
Nine Five
Flush pointing to brick wall with cement sand (F.M. 1.2) Six
PART-G-i : 02- Two
mortar (1:2) with cement including raking out the joints, Thousand
STORIED Hundred
curing at least for 7 days, cost of water, electricity, scaffolding AND
488 SECURITY 74 Sqm 30.000 201.001 and One 6030.030
and other charges etc. all complete in all respect as per Thirty
BUILDING (CIVIL point Zero
drawing and accepted by the Engineer-in-charge. (Cement: point Zero
WORKS) Zero One
CEM-II/B-M) i) Ground floor Three
One Lakh
Forty-
Rule pointing to brick wall with cement sand (F.M. 1.2) mortar Two
PART-G-i : 02- Eight
(1:2) with fresh cement and raking out the joints, curing at Hundred
STORIED Thousand
least for 7 days, cost of water, electricity, scaffolding and and Thirty-
489 SECURITY 75.(i) Sqm 620.000 239.001 148180.620 One
other charges etc. all complete in all respect as per drawing Nine point
BUILDING (CIVIL Hundred
and accepted by the Engineer-in-charge. (Cement: CEM-II/B- Zero Zero
WORKS) and Eighty
M) i) Ground floor One
point Six
Two
490 PART-G-i : 02- 75.(ii) ii) 1st floor Sqm 330.000 254.001 Two 83820.330 Eighty-
STORIED Hundred Three
SECURITY and Fifty- Thousand
BUILDING (CIVIL Four point Eight
WORKS) Zero Zero Hundred
One and
Twenty
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 53/80
3/11/24, 2:55 PM View Form
point
Three
Three
One Lakh
Thirty-
Two Three
PART-G-i : 02-
Hundred Thousand
STORIED
and Sixty- One
491 SECURITY 75.(iii) iii) 2nd floor/ Roof Top Sqm 495.000 269.001 133155.495
Nine point Hundred
BUILDING (CIVIL
Zero Zero and Fifty-
WORKS)
One Five point
Four Nine
Five
Eleven
One
PART-G-i : 02- Supplying, fitting and fixing M.S. flat bar clamp of 150 mm x Thousand
Hundred
STORIED 38 mm x 6 mm size having bifurcated ends to door and Seven
and Thirty-
493 SECURITY 77 window frames with necessary rowel plug, screws etc. Each 90.000 131.001 11790.090 Hundred
One point
BUILDING (CIVIL including cutting grooves in chowkat if necessary etc. all and Ninety
Zero Zero
WORKS) complete and accepted by the Engineer-in-charge. point Zero
One
Nine
One
Three
Thousand
PART-G-i : 02- Hundred
Supplying, fitting and fixing of best quality magnetic door Eight
STORIED and
holder of approved quality including all necessary tools and Hundred
494 SECURITY 78 Each 5.000 374.001 Seventy- 1870.005
accessories all complete and accepted by the Engineer-in- and
BUILDING (CIVIL Four point
charge. Seventy
WORKS) Zero Zero
point Zero
One
Zero Five
One
Six
Thousand
PART-G-i : 02- Thousand
Supplying, fitting and fixing mortice door lock with lever Two
STORIED Two
handle of approved quality including all necessary tools and Hundred
495 SECURITY 79 Each 5.000 1242.001 6210.005 Hundred
accessories etc. all complete approved and accepted by the and Forty-
BUILDING (CIVIL and Ten
Engineer-in-charge. Two point
WORKS) point Zero
Zero Zero
Zero Five
One
Ten
One
PART-G-i : 02- Thousand
Thousand
STORIED Supplying, fitting and fixing rim/round door lock of approved Five
AND Fifty-
496 SECURITY 80 quality including all necessary tools and accessories etc. all Each 10.000 1058.001 10580.010 Hundred
Eight point
BUILDING (CIVIL complete and accepted by the Engineer-in-charge. and Eighty
Zero Zero
WORKS) point Zero
One
One
Four
Thousand
Three
PART-G-i : 02- ''Supplying, fitting and fixing best quality heavy type 19 mm Four
Hundred
STORIED dia and 300 mm long hasp bolt including cutting grooves in Hundred
and Forty-
497 SECURITY 81 door shutter and frames, screws etc. all complete approved Each 13.000 344.001 4472.013 and
Four point
BUILDING (CIVIL and accepted by the Engineer-in-charge. Seventy-
Zero Zero
WORKS) SS Hasp Bolt'' Two point
One
Zero One
Three
Two
Ten
Thousand
Thousand
PART-G-i : 02- Six
Supplying, fitting and fixing hydraulic door closer (big size) of Seven
STORIED Hundred
approved quality including all necessary tools and Hundred
498 SECURITY 82 Each 4.000 2684.001 and 10736.004
accessories etc. all complete and accepted by the Engineer- and Thirty-
BUILDING (CIVIL Eighty-
in-charge. Six point
WORKS) Four point
Zero Zero
Zero Zero
Four
One
One Lakh
Supplying, fitting and fixing MS stair railing with SS hand rail Six Forty-
of standard height with 2 mm thick 62 mm dia SS pipe for Thousand Eight
PART-G-i : 02-
hand-rail, 6 mm thick 4 nos vertical MS plate post in Each Seven Thousand
STORIED
flight, @ 62 mm c/c 12 mm x 12 mm MS solid bar horizontal Hundred Eight
499 SECURITY 83 Sqm 22.000 6768.001 148896.022
10 nos as per drawing, design including carrying, polishing, and Sixty- Hundred
BUILDING (CIVIL
fabricating, welding and fixing with tread by 75 mm long royal Eight point and
WORKS)
bolt with cap etc.all complete and accepted by the Engineer- Zero Zero Ninety-Six
in-charge. One point Zero
Two Two
501 PART-G-i : 02- 84.(ii) ii) 2nd floor/ Roof Top Cum 22.000 10621.001 Ten 233662.022 Two Lakh
STORIED Thousand Thirty-
SECURITY Six Three
BUILDING (CIVIL Hundred Thousand
WORKS) and Six
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 54/80
3/11/24, 2:55 PM View Form
Twenty- Hundred
One point and Sixty-
Zero Zero Two point
One Zero Two
Two
Seventy-
''Apron:
Nine
Providing apron with 50 mm thick cement concrete (1:2:4)
Thousand
with cement, coarse sand and picked jhama chips including One
PART-G-i : 02- One
breaking chips and one layer brick flat soling at bottom with Thousand
STORIED Hundred
first class or picked jhama bricks including cutting earth for AND Fifty-
502 SECURITY 85 Sqm 75.000 1055.001 79125.075 and
preparation of bed and filling the interstices with local sand Five point
BUILDING (CIVIL Twenty-
(F.M. 0.8) including finishing, dressing, curing at least for 7 Zero Zero
WORKS) Five point
days etc. all complete, including cost of water, electricity, One
Zero
other charges accepted by the Engineer-in-charge. (Cement:
Seven
CEM-II/A-M)''
Five
Ten
Anti termite treatment of all wooden doorframes, window One
Thousand
PART-G-i : 02- frames, wood paneling etc. by using DURS BAN 20 EC / Hundred
Six
STORIED equivalent emulsion in the ratio of 1 liter. DURS BAN 20 EC and
Hundred
507 SECURITY 90 + 19 liters of Kerosene oil suitable for wood, plywood, Sqm 55.000 194.001 Ninety- 10670.055
and
BUILDING (CIVIL particle board, hard board etc. on both surfaces by brush on Four point
Seventy
WORKS) both surfaces by brush-on-method etc. complete and Zero Zero
point Zero
accepted by the Engineer-in-charge. One
Five Five
509 PART-G-ii : 02- 1 ''Supplying, fitting and fixing of European type country made Each 1.000 15869.001 Fifteen 15869.001 Fifteen
STORIED best quality glazed porcelain combi closet (two piece), Thousand Thousand
SECURITY including plastic seat cover with soft closing ,cistern system, Eight Eight
BUILDING water consumption 6 litre, siphon wash down/siphon jet Hundred Hundred
(SANITARY single or dual flushinging system which reduce water and Sixty- and Sixty-
WORKS) consumption, hygienic glaze in toilet bowl ,glaze in inner Nine point Nine point
waste line, round bowl, outlet range 280~305 mm. Zero Zero Zero Zero
One One
The sanitary ware shall conform BDS1162:2014. The glaze
shall be thoroughly fused to body. The minimum thickness of
body at any section shall be 5 mm. When assembled
together and when examined from a distance of 60 cm, the
outer surface shall not show to the unaided eye, blemishes
or defects in excess of those listed in BDS standard. The
mean value of water absorption shall not be greater than
0.5% of the ware when dry. When tested with chemical
solutions (Acetic acid, Citric acid, Detergent, Hydrochloric
acid, Sodium hydroxide, Sodium stearate and Sulfuric acid of
various strength) as per BDS1162:2014 procedure, none of
the test pieces should suffer any loss of reflectivity on the
glaze. There shall be no crazing and no stain on the ware.
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 55/80
3/11/24, 2:55 PM View Form
The materials used for making glaze shall not contain lead
compound. In case of certain coloring oxides used for
making colored glaze, the lead content, if any, shall not
exceed 5 percent of the weight of the glaze materials.
Appliances shall be clearly and indelibly marked at a
prominent place, visible even after the appliances are
installed with the following: a) manufacturer's name and/or
registered trademark, b) the number of Bangladesh standard
and c) country of origin. Each product shall also be marked
with the BSTI Certification Mark.
512 PART-G-ii : 02- 4 ''Supplying, fitting and fixing of country made glazed vitreous Each 2.000 4286.001 Four 8572.002 Eight
STORIED standing bowl urinal. Thousand Thousand
SECURITY Two Five
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 56/80
3/11/24, 2:55 PM View Form
BUILDING The sanitary ware shall conform BDS1162:2014. The glaze Hundred Hundred
(SANITARY shall be thoroughly fused to body. The minimum thickness of and and
WORKS) body at any section shall be 5 mm. When assembled Eighty-Six Seventy-
together and when examined from a distance of 60 cm, the point Zero Two point
outer surface shall not show to the unaided eye, blemishes Zero One Zero Zero
or defects in excess of those listed in BDS standard. The Two
mean value of water absorption shall not be greater than
0.5% of the ware when dry. When tested with chemical
solutions (Acetic acid, Citric acid, Detergent, Hydrochloric
acid, Sodium hydroxide, Sodium stearate and Sulfuric acid of
various strength) as per BDS1162:2014 procedure, none of
the test pieces should suffer any loss of reflectivity on the
glaze. There shall be no crazing and no stain on the ware.
The materials used for making glaze shall not contain lead
compound. In case of certain coloring oxides used for
making colored glaze, the lead content, if any, shall not
exceed 5 percent of the weight of the glaze materials.
Appliances shall be clearly and indelibly marked at a
prominent place, visible even after the appliances are
installed with the following: a) manufacturer's name and/or
registered trademark, b) the number of Bangladesh standard
and c) country of origin. Each product shall also be marked
with the BSTI Certification Mark.
Five
Eleven
PART-G-ii : 02- Supplying, fitting and fixing of flush valve for urinal on walls Thousand
Thousand
STORIED or directly over water closet with necessary accessories,, Eight
Seven
SECURITY rowel plugs, making holes wherever required and mending Hundred
514 6 Each 2.000 5853.001 11706.002 Hundred
BUILDING good the damages and fitting, fixing & finishing etc. all and Fifty-
and Six
(SANITARY complete with all necessary fittings and connections Three
point Zero
WORKS) approved and accepted by the Engineer- in- charge. point Zero
Zero Two
Zero One
515 PART-G-ii : 02- 7 ''Supplying, fitting and fixing of country made glazed vitreous Each 3.000 4449.001 Four 13347.003 Thirteen
STORIED W/H wash basin excluding pedestal. Thousand Thousand
SECURITY Four Three
BUILDING The sanitary ware shall conform BDS1162:2014. The glaze Hundred Hundred
(SANITARY shall be thoroughly fused to body. The minimum thickness of and Forty- and Forty-
WORKS) body at any section shall be 5 mm. When assembled Nine point Seven
together and when examined from a distance of 60 cm, the Zero Zero point Zero
outer surface shall not show to the unaided eye, blemishes One Zero
or defects in excess of those listed in BDS standard. The Three
mean value of water absorption shall not be greater than
0.5% of the ware when dry. When tested with chemical
solutions (Acetic acid, Citric acid, Detergent, Hydrochloric
acid, Sodium hydroxide, Sodium stearate and Sulfuric acid of
various strength) as per BDS1162:2014 procedure, none of
the test pieces should suffer any loss of reflectivity on the
glaze. There shall be no crazing and no stain on the ware.
The materials used for making glaze shall not contain lead
compound. In case of certain coloring oxides used for
making colored glaze, the lead content, if any, shall not
exceed 5 percent of the weight of the glaze materials.
Appliances shall be clearly and indelibly marked at a
prominent place, visible even after the appliances are
installed with the following: a) manufacturer's name and/or
registered trademark, b) the number of Bangladesh standard
and c) country of origin. Each product shall also be marked
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 57/80
3/11/24, 2:55 PM View Form
with the BSTI Certification Mark.
Two Ten
PART-G-ii : 02- ''Supplying, fitting and fixing of 5 mm thick unframed super
Thousand Thousand
STORIED quality double coated mirror with all necessary fitting
Five Three
SECURITY including making holes in walls and mending good the
518 10 Each 4.000 2590.001 Hundred 10360.004 Hundred
BUILDING damages with cement mortar (1:4) etc. all complete
and Ninety and Sixty
(SANITARY approved and accepted by the Engineer-in-charge.
point Zero point Zero
WORKS) Local Mirror, 5 mm thickness''
Zero One Zero Four
Seven
One
PART-G-ii : 02- Supplying, fitting and fixing of super quality 600 mm x 125 Thousand
Thousand
STORIED mm coloured glass (plate) shelf having 5 mm thickness with Three
Eight
SECURITY fancy C.P. brackets, screws and frames including making Hundred
519 11 Each 4.000 1830.001 Hundred 7320.004
BUILDING holes in walls and mending good the damages with cement and
and Thirty
(SANITARY mortar (1:4) etc. all complete approved and accepted by the Twenty
point Zero
WORKS) Engineer- in- charge. point Zero
Zero One
Zero Four
Three
PART-G-ii : 02- ''Supplying, fitting and fixing of country made best quality Seven
Thousand
STORIED towel rail/ ring/ shelf minimum 20 mm in dia with C.P. holder Hundred
Five
SECURITY including making holes in walls and mending good the and
520 12.a Each 5.000 718.001 3590.005 Hundred
BUILDING damages with cement mortar (1:4) etc. all complete Eighteen
and Ninety
(SANITARY approved and accepted by the Engineer- in- charge. point Zero
point Zero
WORKS) a) C.P. towel ring/ 450 mm long single towel rail'' Zero One
Zero Five
Two
PART-G-ii : 02- Seven Thousand
STORIED Hundred One
SECURITY and Hundred
521 12.b b) 600 mm long C.P. single towel rail Each 3.000 718.001 2154.003
BUILDING Eighteen and Fifty-
(SANITARY point Zero Four point
WORKS) Zero One Zero Zero
Three
One
PART-G-ii : 02- Thousand
''Supplying, fitting and fixing of best quality toilet paper holder Eight
STORIED Six
of standard size including making holes in walls and mending Hundred
SECURITY Hundred
522 13.a good the damages with cement mortar (1:4) etc. all complete Each 2.000 808.001 and Eight 1616.002
BUILDING and
approved and accepted by the Engineer- in- charge. point Zero
(SANITARY Sixteen
a) Porceain toilet paper holder (any color)'' Zero One
WORKS) point Zero
Zero Two
523 PART-G-ii : 02- 13.b b) Stainless steel toilet paper holder Each 1.000 563.001 Five 563.001 Five
STORIED Hundred Hundred
SECURITY and Sixty- and Sixty-
BUILDING Three Three
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 58/80
3/11/24, 2:55 PM View Form
(SANITARY point Zero point Zero
WORKS) Zero One Zero One
Two
PART-G-ii : 02- Four Thousand
''Supplying, fitting and fixing of standard size country made
STORIED Hundred Five
soap tray including making holes in walls and mending good
SECURITY and Hundred
524 14.a the damages with cement mortar (1:4) etc. all complete Each 6.000 420.001 2520.006
BUILDING Twenty and
approved and accepted by the Engineer- in- charge.
(SANITARY point Zero Twenty
a) Porcelain soap tray (any color)''
WORKS) Zero One point Zero
Zero Six
Six Six
PART-G-ii : 02-
Hundred Thousand
STORIED
and Two
SECURITY
525 14.b b) Stainless steel soap tray Each 10.000 628.001 Twenty- 6280.010 Hundred
BUILDING
Eight point and Eighty
(SANITARY
Zero Zero point Zero
WORKS)
One One
One
PART-G-ii : 02- ''Supplying, fitting and fixing of floor grating net in traps or in Five
Hundred
STORIED drains including making holes in walls/floors and mending Hundred
and
SECURITY good the damages with cement mortar (1:4) etc. all complete and Sixty-
527 16.a Each 3.000 187.001 Eighty- 561.003
BUILDING approved and accepted by the Engineer- in- charge. of One point
Seven
(SANITARY following type Zero Zero
point Zero
WORKS) a) Approx. 50~75 mm dia stainless steel floor grating net'' Three
Zero One
Three Nine
PART-G-ii : 02-
Hundred Hundred
STORIED
and and
SECURITY
528 16.b b) Approx. 100~125 mm dia stainless steel floor grating net Each 3.000 328.001 Twenty- 984.003 Eighty-
BUILDING
Eight point Four point
(SANITARY
Zero Zero Zero Zero
WORKS)
One Three
Six
Nine Thousand
PART-G-ii : 02-
Hundred Nine
STORIED
and Hundred
SECURITY
529 16.c c) Approx. 125 mm x 125 mm stainless steel floor grating net Each 7.000 991.001 Ninety- 6937.007 and Thirty-
BUILDING
One point Seven
(SANITARY
Zero Zero point Zero
WORKS)
One Zero
Seven
Two
PART-G-ii : 02- Five Thousand
STORIED Hundred Two
SECURITY d) 125 mm dia convex cast iron grating on rain water down and Fifty- Hundred
530 16.d Each 4.000 555.001 2220.004
BUILDING pipe (roof top) Five point and
(SANITARY Zero Zero Twenty
WORKS) One point Zero
Zero Four
Supplying, fitting and fixing of 100 mm inside diameter & wall Nine Forty-One
PART-G-ii : 02-
thickness 2.7 mm - 3.4 mm best quality uPVC rain water Hundred Thousand
STORIED
down pipe fitting, fixed in position with head and shoes, and Seven
SECURITY
531 17 bends, min.20 mm width F.I. Bar clamp and nails, and Each 42.000 993.001 Ninety- 41706.042 Hundred
BUILDING
including all accessories such as round grating/domed roof Three and Six
(SANITARY
grating, bands, sockets approved and accepted by the point Zero point Zero
WORKS)
Engineer- in- charge. Zero One Four Two
One Lakh
Eight
PART-G-ii : 02- Forty
Hundred
STORIED Thousand
and
SECURITY Nine
533 18.b b) 100 mm inside dia wall thickness 3.4 mm - 4.0 mm Rm 160.000 881.001 Eighty- 140960.160
BUILDING Hundred
One point
(SANITARY and Sixty
Zero Zero
WORKS) point One
One
Six
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 59/80
3/11/24, 2:55 PM View Form
One
Eleven
PART-G-ii : 02- Thousand
Thousand
STORIED One
b) 40 mm dia G.I. pipe with wall thickness 3.25 mm, outside Four
SECURITY Hundred
535 19.b diameter min 46.5 mm, weight 3.83 kg/m, can withstand min Rm 10.000 1146.001 11460.010 Hundred
BUILDING and Forty-
50 kg/cm2 hydraulic pressure. and Sixty
(SANITARY Six point
point Zero
WORKS) Zero Zero
One
One
Four
One Thousand
PART-G-ii : 02-
Thousand Five
STORIED
c) 50 mm dia G.I. pipe with wall thickness 3.65 mm, outside Five Hundred
SECURITY
536 19.c diameter min 57.3 mm, weight 5.38 kg/m, can withstand min Rm 3.000 1504.001 Hundred 4512.003 and
BUILDING
50 kg/cm2 hydraulic pressure. and Four Twelve
(SANITARY
point Zero point Zero
WORKS)
Zero One Zero
Three
Two
PART-G-ii : 02- Thirteen
Thousand
STORIED Thousand
d) 75 -80 mm dia G.I. pipe with wall thickness 3.25 mm, Six
SECURITY AND
537 19.d outside diameter min 86.5 mm, weight 7.22 kg/m, can Rm 5.000 2607.001 Hundred 13035.005
BUILDING Thirty-Five
withstand min 50 kg/cm2 hydraulic pressure. and Seven
(SANITARY point Zero
point Zero
WORKS) Zero Five
Zero One
One Eight
PART-G-ii : 02- ''Supplying and laying uPVC pipe for underground including Thousand Thousand
STORIED fitting, fixing etc. all complete approved and accepted by the Four Four
SECURITY Engineer- in- charge. Hundred Hundred
538 20.a Rm 6.000 1416.001 8496.006
BUILDING a) 150 mm dia with wall thickness 4.5 mm - 6.6 mm uPVC and and
(SANITARY pipe Sixteen Ninety-Six
WORKS) '' point Zero point Zero
Zero One Zero Six
Two Lakh
Two
PART-G-ii : 02- Forty-One
Thousand
STORIED Thousand
One
SECURITY b) 200 mm dia with wall thickness 5.3 mm - 7.8 mm uPVC Nine
539 20.b Rm 115.000 2104.001 Hundred 241960.115
BUILDING pipe Hundred
and Four
(SANITARY and Sixty
point Zero
WORKS) point One
Zero One
One Five
Three Eleven
PART-G-ii : 02-
Hundred Thousand
STORIED
and Six
SECURITY
541 21.(ii) ii) 19 mm dia wall thickness 2.9 mm - 3.4 mm Rm 30.000 387.001 Eighty- 11610.030 Hundred
BUILDING
Seven and Ten
(SANITARY
point Zero point Zero
WORKS)
Zero One Three
Six Three
PART-G-ii : 02-
Hundred Thousand
STORIED
and Seven
SECURITY
543 21.(iv) iv) 32 mm dia wall thickness 3.6 mm - 4.2 mm Rm 6.000 625.001 Twenty- 3750.006 Hundred
BUILDING
Five point and Fifty
(SANITARY
Zero Zero point Zero
WORKS)
One Zero Six
Twenty
PART-G-ii : 02- Eight Thousand
STORIED Hundred Eight
SECURITY and Sixty- Hundred
544 21.(v) v) 37 mm dia wall thickness 3.7 mm - 4.3 mm Rm 24.000 868.001 20832.024
BUILDING Eight point and Thirty-
(SANITARY Zero Zero Two point
WORKS) One Zero Two
Four
One
Thousand Eighty-
PART-G-ii : 02-
Four Nine
STORIED
Hundred Thousand
SECURITY
545 21.(vi) vi) 50 mm dia wall thickness 3.9 mm - 4.5 mm Rm 60.000 1485.001 and 89100.060 One
BUILDING
Eighty- Hundred
(SANITARY
Five point point Zero
WORKS)
Zero Zero Six
One
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 60/80
3/11/24, 2:55 PM View Form
One
PART-G-ii : 02- Four Thousand
STORIED ''Supplying, fitting and fixing of best quality G.I. gate valve Hundred Eight
SECURITY with sealant etc. complete approved and accepted by the and Fifty- Hundred
547 23.(i) Each 4.000 459.001 1836.004
BUILDING Engineer- in- charge. Nine point and Thirty-
(SANITARY i) 12 mm brass gate valve'' Zero Zero Six point
WORKS) One Zero Zero
Four
Two
PART-G-ii : 02- Six Thousand
STORIED Hundred Five
SECURITY and Thirty- Hundred
548 23.(ii) ii) 20 mm brass gate valve Each 4.000 633.001 2532.004
BUILDING Three and Thirty-
(SANITARY point Zero Two point
WORKS) Zero One Zero Zero
Four
Seven
PART-G-ii : 02- Seven
Thousand
STORIED Hundred
Four
SECURITY and Forty-
549 23.(iii) iii) 25 mm brass Gate valve Each 10.000 746.001 7460.010 Hundred
BUILDING Six point
and Sixty
(SANITARY Zero Zero
point Zero
WORKS) One
One
One Four
Thousand Thousand
PART-G-ii : 02-
Two Eight
STORIED
Hundred Hundred
SECURITY
550 23.(iv) iv) 40 mm brass gate valve Each 4.000 1221.001 and 4884.004 and
BUILDING
Twenty- Eighty-
(SANITARY
One point Four point
WORKS)
Zero Zero Zero Zero
One Four
One
Thousand
PART-G-ii : 02- Seven
Eight
STORIED Thousand
Hundred
SECURITY Five
551 23.(v) v) 50 mm brass gate valve Each 4.000 1875.001 and 7500.004
BUILDING Hundred
Seventy-
(SANITARY point Zero
Five point
WORKS) Zero Four
Zero Zero
One
Five Five
PART-G-ii : 02- Thousand Thousand
STORIED One One
SECURITY Hundred Hundred
552 23.(vi) vi) 75 mm brass gate valve Each 1.000 5139.001 5139.001
BUILDING and Thirty- and Thirty-
(SANITARY Nine point Nine point
WORKS) Zero Zero Zero Zero
One One
One
PART-G-ii : 02-
Hundred Seven
STORIED ''Supplying, fitting and fixing of G.I. Union with sealant etc.
and Hundred
SECURITY complete in all respects approved and accepted by the
553 24.(i) Each 4.000 177.001 Seventy- 708.004 and Eight
BUILDING Engineer- in- charge.
Seven point Zero
(SANITARY i) 12 mm dia G.I. Union''
point Zero Zero Four
WORKS)
Zero One
Two
PART-G-ii : 02- Nine
Hundred
STORIED Hundred
and
SECURITY and
554 24.(ii) ii) 20 mm dia G.I. Union Each 4.000 228.001 Twenty- 912.004
BUILDING Twelve
Eight point
(SANITARY point Zero
Zero Zero
WORKS) Zero Four
One
Two Two
PART-G-ii : 02-
Hundred Thousand
STORIED
and Seven
SECURITY
555 24.(iii) iii) 25 mm dia G.I. Union Each 10.000 274.001 Seventy- 2740.010 Hundred
BUILDING
Four point and Forty
(SANITARY
Zero Zero point Zero
WORKS)
One One
One
Four
PART-G-ii : 02- Thousand
Hundred
STORIED Nine
and
SECURITY Hundred
556 24.(iv) iv) 40 mm dia G.I. Union Each 4.000 491.001 Ninety- 1964.004
BUILDING and Sixty-
One point
(SANITARY Four point
Zero Zero
WORKS) Zero Zero
One
Four
Five Two
PART-G-ii : 02-
Hundred Thousand
STORIED
and One
SECURITY
557 24.(v) v) 50 mm dia G.I. Union Each 4.000 526.001 Twenty- 2104.004 Hundred
BUILDING
Six point and Four
(SANITARY
Zero Zero point Zero
WORKS)
One Zero Four
One
Two
PART-G-ii : 02- Thousand
Thousand
STORIED ''Supplying, fitting and fixing of best quality G.I. check valve, Two
Five
SECURITY threaded joint with sealant etc. complete approved and Hundred
558 25.(i) Each 2.000 1270.001 2540.002 Hundred
BUILDING accepted by the Engineer- in- charge. and
and Forty
(SANITARY i) 40 mm brass check valve'' Seventy
point Zero
WORKS) point Zero
Zero Two
Zero One
559 PART-G-ii : 02- 26.(i) ''Supplying, fitting and fixing of best quality G.I. float valve, Each 2.000 1316.001 One 2632.002 Two
STORIED threaded joint Pit valve etc. complete approved and accepted Thousand Thousand
SECURITY Three Six
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 61/80
3/11/24, 2:55 PM View Form
BUILDING by the Engineer- in- charge. Hundred Hundred
(SANITARY i) 40 mm brass float valve'' and and Thirty-
WORKS) Sixteen Two point
point Zero Zero Zero
Zero One Two
Two
''Supplying different inside dia best quality uPVC clean out / Thousand
PART-G-ii : 02- Three
trap having specific gravity 1.35 -1.45 and other physical, One
STORIED Hundred
chemical, themal, fire resistivity properties etc. as per BSTI Hundred
SECURITY and Fifty-
560 27.(i) approved manufacturer standards or ASTM, BS/ISO/IS Each 6.000 354.001 2124.006 and
BUILDING Four point
standards, fitting and fixing in position etc. complete Twenty-
(SANITARY Zero Zero
approved and accepted by the Engineer- in- charge. Four point
WORKS) One
i) 50 mm dia uPVC Y or T - Y Cleanout'' Zero Zero
Six
One
Six
PART-G-ii : 02- Thousand
Hundred
STORIED Three
and
SECURITY Hundred
561 27.(ii) ii) 50 mm dia uPVC ?P? or ?S? trap Each 2.000 693.001 Ninety- 1386.002
BUILDING and
Three
(SANITARY Eighty-Six
point Zero
WORKS) point Zero
Zero One
Zero Two
Six Six
PART-G-ii : 02-
Hundred Thousand
STORIED
and Seven
SECURITY
562 27.(iii) iii) 100 mm dia uPVC Y or T - Y Cleanout Each 10.000 671.001 Seventy- 6710.010 Hundred
BUILDING
One point and Ten
(SANITARY
Zero Zero point Zero
WORKS)
One One
Six
PART-G-ii : 02-
Four Thousand
STORIED
Hundred One
SECURITY
563 27.(iv) iv) 100 mm dia uPVC ?P? or ?S? trap Each 14.000 440.001 and Forty 6160.014 Hundred
BUILDING
point Zero and Sixty
(SANITARY
Zero One point Zero
WORKS)
One Four
Thirteen
Nine
PART-G-ii : 02- Thousand
Hundred
STORIED Eight
and
SECURITY Hundred
566 29.b b) CP angle stop cock Each 14.000 988.001 Eighty- 13832.014
BUILDING and Thirty-
Eight point
(SANITARY Two point
Zero Zero
WORKS) Zero One
One
Four
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 62/80
3/11/24, 2:55 PM View Form
''Supplying, fitting and fixing of best quality sink cock made
from copper or copper alloy, chromium plated.
The faucet conforms BDS EN 200:2009 . The faucet tap shall
be free from any leakage, permeation and other
abnormalities. The water hammer value shall be 1.47 Mpa or One One
under. The faucet after it has been operated 100000 times it Thousand Thousand
PART-G-ii : 02-
shall be free from a seat- leakage and shall satisfy the Six Six
STORIED
reverse flow preventing performance. The inside and outside Hundred Hundred
SECURITY
568 31 surfaces of the faucet shall be smooth and be free from Each 1.000 1685.001 and 1685.001 and
BUILDING
blowholes, fissures, remarkable flows or injurious defects. Eighty- Eighty-
(SANITARY
The chromium plating on the faucet shall be of class 2 grade Five point Five point
WORKS)
1. The final coating should be done with chromium of Zero Zero Zero Zero
minimum 0.1 micron. One One
The faucet shall be made leak proof and fixing in position
with selected tape etc. , all complete approved and accepted
by the Engineer- in- charge.
12 mm CP concealed super quality moving sink cock''
Two
Thousand Eleven
PART-G-ii : 02-
Two Thousand
STORIED ''Supplying and fitting-fixing Chromium plated (CP) Shower
Hundred Three
SECURITY head. all complete approved and accepted by the Engineer-
571 34 Each 5.000 2276.001 and 11380.005 Hundred
BUILDING in- charge.
Seventy- and Eighty
(SANITARY Moving type 150 mm CP shower head''
Six point point Zero
WORKS)
Zero Zero Zero Five
One
Two
PART-G-ii : 02- One
Thousand
STORIED ''Supplying and fitting-fixing stainless steel hand / push Thousand
AND
SECURITY shower for ablution including holder etc. all complete AND
572 35 Each 2.000 1049.001 2098.002 Ninety-
BUILDING approved and accepted by the Engineer- in- charge. Forty-Nine
Eight point
(SANITARY Moving type push shower'' point Zero
Zero Zero
WORKS) Zero One
Two
One
One Thousand
PART-G-ii : 02-
Hundred Nine
STORIED
''Supplying, fitting and fixing of 12 mm dia connection pipe and Hundred
SECURITY
573 36.a approved and accepted by the Engineer- in- charge. Each 16.000 124.001 Twenty- 1984.016 and
BUILDING
a) 600 mm long plastic flexible lead (connection) pipe'' Four point Eighty-
(SANITARY
Zero Zero Four point
WORKS)
One Zero One
Six
Two
PART-G-ii : 02- Four
Hundred
STORIED Hundred
and
SECURITY and Forty-
574 36.b b) 600 mm long metal cover connection pipe Each 2.000 222.001 Twenty- 444.002
BUILDING Four point
Two point
(SANITARY Zero Zero
Zero Zero
WORKS) Two
One
576 PART-G-ii : 02- 37.b b) Groove size 75 mm x 75 mm (For 25 mm to 40 mm dia Rm 35.000 535.001 Five 18725.035 Eighteen
STORIED pipes) Hundred Thousand
SECURITY and Thirty- Seven
BUILDING Five point Hundred
(SANITARY Zero Zero and
WORKS) One Twenty-
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 63/80
3/11/24, 2:55 PM View Form
Five point
Zero
Three Five
Seven
One
Thousand
PART-G-ii : 02- Thousand
Two
STORIED Eight
Hundred
SECURITY Supply, fitting & fixing of 600 mm dia C.I. man hole cover etc. Hundred
577 38 Each 4.000 1819.001 7276.004 and
BUILDING all complete approved by the Engineer- in- charge. and
Seventy-
(SANITARY Nineteen
Six point
WORKS) point Zero
Zero Zero
Zero One
Four
One Lakh
Nine
Thirty-
Thousand
PART-G-ii : 02- Three
Five
STORIED b) Clear 525 mm x 525 mm and depth 675 mm to 825 mm, Thousand
Hundred
SECURITY average 750 mm for single 225 mm dia R.C.C. pipes and Three
580 40.b Each 14.000 9526.001 and 133364.014
BUILDING 400 mm PVC pipe with pit cover and 450 mm dia C.I. man- Hundred
Twenty-
(SANITARY hole cover. and Sixty-
Six point
WORKS) Four point
Zero Zero
Zero One
One
Four
Twelve Twelve
PART-G-ii : 02- Thousand Thousand
STORIED c) Clear 600 mm x 600 mm and depth 750 mm to 900 mm, Five Five
SECURITY average 825 mm for single 300 mm dia R.C.C. pipes and Hundred Hundred
581 40.c Each 1.000 12554.001 12554.001
BUILDING 375 mm and 400 mm PVC pipe with pit cover and 450 mm and Fifty- and Fifty-
(SANITARY dia C.I. man-hole cover. Four point Four point
WORKS) Zero Zero Zero Zero
One One
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 64/80
3/11/24, 2:55 PM View Form
''Concealed conduit Point wiring (BYM) (without switch):
Concealed conduit wiring for following Point looping at the
switch board with earth terminal with 1C-2x1.5 sqmm PVC
insulated and sheathed stranded cable (BYM) & same size
PVC insulated ECC (BYA) (Green / White color) including
circuit wiring with IC-2x2.5 sqmm PVC insulated and
sheathed stranded cable (BYM) & same size PVC insulated
ECC (BYA) Green / White color through PVC conduit (one
conduit from switch board to common Point on ceiling is One Lakh
One
considered to draw 3 pair of cable ) of reputed manufacturer Fifty-One
PART-G-iii : 02- Thousand
of minimum 25 mm dia & 1.5 mm wall thickness complete Thousand
STORIED Two
with 18 SWG GP sheet / PVC switch board & pull box with Three
SECURITY Hundred
585 1.0 3mm thick ebonite sheet cover, without switch, fixing Point 120.000 1261.001 151320.120 Hundred
BUILDING and Sixty-
materials etc.(without switch) as required including mending and
(ELECTRICAL One point
the damages good. All electrical contacts shall be of brass / Twenty
WORKS) Zero Zero
copper connected through connector or soldering (no twisting point One
One
shall be allowed) and cables shall be manufactured and Two
tested according to relevant IEC / BDS / BS / VDE standards
and as per detailed specification mentioned in Annexure-1.
The work shall be carried out as per direction & approval of
the Engineer. Cable manufacturer(s) must have valid test
certificate (within last seven years ) from internationally
accrediated laboratory (like CPRI, KEMA etc) accepted /
approved by the Engineer.
1.1) Light/ exhaust or wall bracket fan Point''
Twenty-
One
Seven
PART-G-iii : 02- Thousand
Thousand
STORIED Two
Seven
SECURITY Hundred
586 1.2 Fan Point Point 22.000 1261.001 27742.022 Hundred
BUILDING and Sixty-
and Forty-
(ELECTRICAL One point
Two point
WORKS) Zero Zero
Zero Two
One
Two
One Two
PART-G-iii : 02- Thousand Thousand
STORIED Three Six
SECURITY Hundred Hundred
587 1.3 Call bell Point with gang bell push Point 2.000 1333.001 2666.002
BUILDING and Thirty- and Sixty-
(ELECTRICAL Three Six point
WORKS) point Zero Zero Zero
Zero One Two
Three Eleven
PART-G-iii : 02-
Hundred Thousand
STORIED
1C-2x4.0 sqmm (BYM) cable with 4 sqmm (BYA) ECC wire and One
SECURITY
589 2.2 through PVC pipe of minimum inner dia 20 mm having wall Rm 30.000 372.001 Seventy- 11160.030 Hundred
BUILDING
thickness of 1.5 mm Two point and Sixty
(ELECTRICAL
Zero Zero point Zero
WORKS)
One Three
Four Nine
PART-G-iii : 02-
Hundred Thousand
STORIED
1C-2x6.0 sqmm (BYM) cable with 6 sqmm (BYA) ECC wire and Eight
SECURITY
590 2.3 through PVC pipe of minimum inner dia 25 mm having wall Rm 20.000 492.001 Ninety- 9840.020 Hundred
BUILDING
thickness of 1.5 mm Two point and Forty
(ELECTRICAL
Zero Zero point Zero
WORKS)
One Two
592 PART-G-iii : 02- 3.2 1C-4x4 sqmm (NYY / 2XY) with 4 sqmm (BYA) ECC wire Rm 20.000 667.001 Six 13340.020 Thirteen
STORIED through PVC pipe of minimum inner dia 30 mm having wall Hundred Thousand
SECURITY thickness of 1.9 mm and Sixty- Three
BUILDING Seven Hundred
and Forty
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 65/80
3/11/24, 2:55 PM View Form
(ELECTRICAL point Zero point Zero
WORKS) Zero One Two
Seven
PART-G-iii : 02- Two
Thousand
STORIED Hundred
1C-2x2.5sqmm (BYM) cable with 2.5 sqmm (BYA) ECC wire Eight
SECURITY and Sixty-
594 4.2 through PVC pipe of minimum inner dia 25 mm having wall Rm 30.000 261.001 7830.030 Hundred
BUILDING One point
thickness of 1.7 mm and Thirty
(ELECTRICAL Zero Zero
point Zero
WORKS) One
Three
Six
PART-G-iii : 02- Three
Thousand
STORIED Hundred
1C-2x4.0 sqmm (BYM) cable with 4 sqmm (BYA) ECC wire Seven
SECURITY and Thirty-
595 4.3 through PVC pipe of minimum inner dia 25 mm having wall Rm 20.000 338.001 6760.020 Hundred
BUILDING Eight point
thickness of 1.7 mm and Sixty
(ELECTRICAL Zero Zero
point Zero
WORKS) One
Two
Thirty-
One
Four
PART-G-iii : 02- Thousand
Thousand
STORIED Seven
1C-4x16sqmm (NYY / 2XY) with 16 sqmm (BYA) ECC wire Two
SECURITY Hundred
598 5.2 through PVC pipe of minimum inner dia 40 mm having wall Rm 20.000 1711.001 34220.020 Hundred
BUILDING and
thickness of 2.2 mm and
(ELECTRICAL Eleven
Twenty
WORKS) point Zero
point Zero
Zero One
Two
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 66/80
3/11/24, 2:55 PM View Form
Seven
PART-G-iii : 02- Seven
Thousand
STORIED Hundred
One
SECURITY 5 - 10 Amps. Made in HONGKONG / MALAYSIA / and
600 6.b Each 10.000 715.001 7150.010 Hundred
BUILDING SINGAPORE / S KOREA / THAILAND Fifteen
and Fifty
(ELECTRICAL point Zero
point Zero
WORKS) Zero One
One
One
Three Thousand
PART-G-iii : 02-
Hundred Eight
STORIED
and Hundred
SECURITY
602 7.2 Two gang switch Each 5.000 375.001 Seventy- 1875.005 and
BUILDING
Five point Seventy-
(ELECTRICAL
Zero Zero Five point
WORKS)
One Zero Zero
Five
Four
PART-G-iii : 02- Five Thousand
STORIED Hundred One
SECURITY and Hundred
603 7.3 Three gang switch Each 8.000 514.001 4112.008
BUILDING Fourteen and
(ELECTRICAL point Zero Twelve
WORKS) Zero One point Zero
Zero Eight
Three
PART-G-iii : 02- Seven Thousand
STORIED Hundred Eight
SECURITY and Sixty- Hundred
604 7.4 Four gang switch Each 5.000 763.001 3815.005
BUILDING Three and
(ELECTRICAL point Zero Fifteen
WORKS) Zero One point Zero
Zero Five
One
PART-G-iii : 02- Five
Thousand
STORIED Hundred
AND
SECURITY and
605 7.5 One gang switch & one 5 amps. 2-pin socket combined. Each 2.000 512.001 1024.002 Twenty-
BUILDING Twelve
Four point
(ELECTRICAL point Zero
Zero Zero
WORKS) Zero One
Two
One Twenty-
Thousand Six
PART-G-iii : 02-
One Thousand
STORIED
''Gang type Fan Regulator Hundred One
SECURITY
606 8 Made in HONGKONG / MALAYSIA / SINGAPORE / S Each 22.000 1187.001 and 26114.022 Hundred
BUILDING
KOREA / THAILAND '' Eighty- and
(ELECTRICAL
Seven Fourteen
WORKS)
point Zero point Zero
Zero One Two Two
Four Four
PART-G-iii : 02-
Hundred Hundred
STORIED
''Gang type Calling bell Push and and
SECURITY
607 9 Made in MALAYSIA / THAILAND / SINGAPORE / Each 1.000 482.001 Eighty- 482.001 Eighty-
BUILDING
HONGKONG / S.KOREA. .'' Two point Two point
(ELECTRICAL
Zero Zero Zero Zero
WORKS)
One One
PART-G-iii : 02-
Six Six
STORIED
''Gang type Telephone / TV Socket Hundred Hundred
SECURITY
608 10 Made in HONGKONG / MALAYSIA / SINGAPORE / S Each 1.000 609.001 and Nine 609.001 and Nine
BUILDING
KOREA / THAILAND '' point Zero point Zero
(ELECTRICAL
Zero One Zero One
WORKS)
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 67/80
3/11/24, 2:55 PM View Form
Three
Seven
PART-G-iii : 02- Thousand
Thousand
STORIED Six
Two
SECURITY ''1220 mm. (48'''') Sweep Hundred
611 12.b Each 2.000 3620.001 7240.002 Hundred
BUILDING Input power : Maximum 65 watt.'' and
and Forty
(ELECTRICAL Twenty
point Zero
WORKS) point Zero
Zero Two
Zero One
Three
One Thousand
PART-G-iii : 02-
Hundred Seven
STORIED FAN CLAMP: Providing & fixing box type fan clamp made of
and Hundred
SECURITY 25.4 mm. x 6.35 mm. (1''x ¼'') MS flat bar with 15.87 mm.
612 13 Each 22.000 172.001 Seventy- 3784.022 and
BUILDING (5/8'') dia MS hook including necessary bolts, nuts etc. as
Two point Eighty-
(ELECTRICAL required as per sample approved by the Engineer.
Zero Zero Four point
WORKS)
One Zero Two
Two
One
''EXHAUST FAN: Providing and fixing of following axial flow Seven
Thousand
PART-G-iii : 02- AC capacitor type wall mounted exhaust fan complete with Thousand
Five
STORIED blade, steel frame standard wall louver shutter, PVC Nine
Hundred
SECURITY insulated connecting wire etc. complete as required including Hundred
613 14 Each 5.000 1583.001 and 7915.005
BUILDING cutting wall and mending good the damages as per direction and
Eighty-
(ELECTRICAL of the Engineer. Fifteen
Three
WORKS) 12'''' Exhaust fan plastic body (foreign made accepted / point Zero
point Zero
approved by the Engineer).'' Zero Five
Zero One
617 PART-G-iii : 02- 18 ''TUBE & PANEL LIGHT FITTINGS (LED) Supply & fixing Each 40.000 1620.001 One 64800.040 Sixty-Four
STORIED LED tube & panel light fittings of following specifications: Thousand Thousand
SECURITY Luminous efficacy: 100 lm/W(minimum) Six Eight
BUILDING Power Factor: minimum 0.95 Hundred Hundred
(ELECTRICAL Colour Rendering Index(Ra) : and point Zero
WORKS) i) For Residential building Ra≥80 Twenty Four
ii) For office and other types of buildings 70≤Ra< 85 point Zero
Driver : MEANWELL/OSRAM / ENERGY+/ Zero One
SIGNIFY(PHILIPS) or equivalent IEC standard,
LED chips :EPISTAR / OSRAM / SIGNIFY(PHILIPS) / CREE
/ BRIDGELUX or equivalent.
Colour temperature : 3500K-6500K (Warm-White)
Model & sample to be accepted / approved by the Engineer-
in-charge (with 2 years warranty).
Material: Aluminium Alloy ABS Plastic
GLORIA cat No- GTF (LED). 774
Energy+EPTL-1023
Cosmo Cat no-BDTCL-LE-xTS-01
Adex -AD BL 840
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 68/80
3/11/24, 2:55 PM View Form
Asha Cat no-ACS ?LTLS-1635
Megaman-MXL2027
or equivalent.
4'x36W''
''
622 PART-G-iii : 02- 23.1 ''SINGLE PHASE DISTRIBUTION BOARD (SPDB): Each 1.000 12829.001 Twelve 12829.001 Twelve
STORIED Providing and fixing single phase distribution board (SPDB) Thousand Thousand
SECURITY [concealed / surface] having the following components and Eight Eight
BUILDING specifications: [Fig : 4.2]. 1. Steel board : Approximate size: Hundred Hundred
(ELECTRICAL 20''''x15''''x4'''' and and
WORKS) MS sheet : 18SWG with hinged type door and locking Twenty- Twenty-
arrangement duly painted with powder coating with epoxy Nine point Nine point
polyester resin on all surfaces of board (gray / off-white) etc. Zero Zero Zero Zero
In front side there will be tempered thick fiber glass of One One
minimum 8 mm thickness with rubber gaskets to observe the
inside arrangement. 2. Copper bar: Approximate size: 10''''x
1''''x 3mm(2 nos) and 6''''x 1''''x 3mm, (1 no) mounted on
insulator at both ends, capacity: 60-100A . 3. 1 No.
DPMCB(main control) and following nos.SPMCB, DPMCB
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 69/80
3/11/24, 2:55 PM View Form
and SPMCB Manufactured / Assembled and tested in
accordance with relevant BDS IEC 60898-1:2016 and IEC /
VDE / NEMA / BS / JIS standard.
Minimum breaking capacity 6/10 KA with thermal overcurrent
and instantaneous electromagnetic short circuit release. 4.
Loop Cable [from phase bar to SPMCB(circuit & power)]
Size: 1C-1x2.5 sq mm (BYM) with DPMCB and SPMCBs
accepted / approved by the Engineer-in-charge.
23.1) 6-way SPDB
Incoming : 1x40A DPMCB (6 KA)
Outgoing : 6x5-10A SPMCB (6 KA)''
Fourteen Fourteen
Thousand Thousand
PART-G-iii : 02-
One One
STORIED
''8-way SPDB Hundred Hundred
SECURITY
623 23.2 Incoming : 1x50A DPMCB (10 KA) Each 1.000 14179.001 and 14179.001 and
BUILDING
Outgoing : 8x5-10A SPMCB (10 KA)'' Seventy- Seventy-
(ELECTRICAL
Nine point Nine point
WORKS)
Zero Zero Zero Zero
One One
Sixteen Sixteen
Thousand Thousand
PART-G-iii : 02-
Five Five
STORIED
''10-way SPDB Hundred Hundred
SECURITY
624 23.3 Incoming : 1x60A/63A DPMCB (10 KA) Each 1.000 16571.001 and 16571.001 and
BUILDING
Outgoing : 10x5-10A SPMCB (10 KA)'' Seventy- Seventy-
(ELECTRICAL
One point One point
WORKS)
Zero Zero Zero Zero
One One
''TPMCCB: Providing & fixing on a prepared board 500 volt Seven Forty-Four
PART-G-iii : 02- grade following triple-pole molded case circuit breaker Thousand Thousand
STORIED (TPMCCB) with thermal over-current and instantaneous Four Seven
SECURITY electromagnetic short circuit release provision, manufactured Hundred Hundred
631 27.a Each 6.000 7466.001 44796.006
BUILDING and tested in accordance with relevant IEC / VDE / NEMA / and Sixty- and
(ELECTRICAL BS / JIS standards. Six point Ninety-Six
WORKS) TPMCCB accepted / approved by the engineer. Zero Zero point Zero
a) 15 Amps. (minimum 10-KA)'' One Zero Six
632 PART-G-iii : 02- 27.b 40 Amps. (minimum 10-KA) Each 1.000 7466.001 Seven 7466.001 Seven
STORIED Thousand Thousand
SECURITY Four Four
BUILDING Hundred Hundred
and Sixty- and Sixty-
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 70/80
3/11/24, 2:55 PM View Form
(ELECTRICAL Six point Six point
WORKS) Zero Zero Zero Zero
One One
Seven Seven
PART-G-iii : 02- Thousand Thousand
STORIED Four Four
SECURITY Hundred Hundred
633 27.c 50 Amps. (minimum 10-KA) Each 1.000 7466.001 7466.001
BUILDING and Sixty- and Sixty-
(ELECTRICAL Six point Six point
WORKS) Zero Zero Zero Zero
One One
Seven Seven
PART-G-iii : 02- Thousand Thousand
STORIED Four Four
SECURITY Hundred Hundred
634 27.d 60 Amps. (minimum 10-KA) Each 1.000 7466.001 7466.001
BUILDING and Sixty- and Sixty-
(ELECTRICAL Six point Six point
WORKS) Zero Zero Zero Zero
One One
Two
''BUS - BAR: Providing and fixing 500 V 3-phase bus-bar Five
PART-G-iii : 02- Thousand
system assembled in prelaid board with porcelain insulators. Thousand
STORIED Five
There will be equal size holes on every bar at 0.5'''' interval AND
SECURITY Hundred
636 29.a and bar to bar gap shall be 2'''' - 3''''. Each 2.000 2544.001 5088.002 Eighty-
BUILDING and Forty-
a) 60 - 100 Amps. Copper flat bar (5 nos) : 4 nos 9'''' Eight point
(ELECTRICAL Four point
x1''''x3mm and 1 no 4''''x1''''x4mm for earthing mounted on Zero Zero
WORKS) Zero Zero
insulator at both ends individually.'' Two
One
Six Six
Thousand Thousand
PART-G-iii : 02-
Two Two
STORIED
200 - 300 Amps. Copper flat bar (5 nos) : 4 nos 15''x1''x8mm Hundred Hundred
SECURITY
637 29.b and 1 no 4''x1''x8mm for earthing mounted on insulator at Each 1.000 6225.001 and 6225.001 and
BUILDING
both ends individually. Twenty- Twenty-
(ELECTRICAL
Five point Five point
WORKS)
Zero Zero Zero Zero
One One
One
Fifty-Six
PART-G-iii : 02- Thousand
Thousand
STORIED One
Providing & drawing no-2 HDBC wire through 12.7 mm. (½'') Six
SECURITY Hundred
641 33 dia G.I. pipe including fitting, fixing the G.I. pipe in wall or Rm 50.000 1133.001 56650.050 Hundred
BUILDING and Thirty-
column complete as required. and Fifty
(ELECTRICAL Three
point Zero
WORKS) point Zero
Five
Zero One
642 PART-G-iii : 02- 34 ''TELECOMMUNICATION CABLE: Supplying and drawing of Rm 200.000 34.001 Thirty- 6800.200 Six
STORIED following sizes PVC insulated & sheathed twisted pair Four point Thousand
SECURITY telecommunication cables having dia of Each core is 0.6 mm Zero Zero Eight
BUILDING through prelaid pipes. One Hundred
(ELECTRICAL Cable manufacturer(s) must have valid test certificate from point Two
WORKS) internationally accrediated laboratory (like CPRI, KEMA etc)
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 71/80
3/11/24, 2:55 PM View Form
approved / accepted by the Engineer.
a) 1C-4x0.282 sqmm (2 pair)''
Three
PART-G-iii : 02-
Hundred
STORIED Seventy-
and
SECURITY Nine point
645 35.c 25 sqmm Rm 5.000 79.001 395.005 Ninety-
BUILDING Zero Zero
Five point
(ELECTRICAL One
Zero Zero
WORKS)
Five
PART-G-iii : 02-
Six
STORIED Sixty-
Thousand
SECURITY b) Minimum inner dia 25 mm & minimum wall thickness 1.5 Seven
650 39.b Rm 100.000 67.001 6700.100 Seven
BUILDING mm. point Zero
Hundred
(ELECTRICAL Zero One
point One
WORKS)
PART-G-iii : 02-
Nine
STORIED Ninety-
Thousand
SECURITY c) Minimum inner dia 30 mm & minimum wall thickness 1.5 Two point
651 39.c Rm 100.000 92.001 9200.100 Two
BUILDING mm. Zero Zero
Hundred
(ELECTRICAL One
point One
WORKS)
Sixteen Three
''LOOP CABLE: Supply and fixing of loop cable of this
PART-G-iii : 02- Thousand Lakh
following sizes : Cable manufacturer(s) must have valid type
STORIED Four Twenty-
test certificate (within last seven years) from internationally
SECURITY Hundred Nine
652 40.a accredited laboratory (like CPRI, KEMA etc.) accepted / Rm 20.000 16453.001 329060.020
BUILDING and Fifty- Thousand
approved by the Engineer In Charge.
(ELECTRICAL Three AND Sixty
a) From transformer to LT switchgear (without ECC & conduit
WORKS) point Zero point Zero
) ,1C - 4 x 240 sqmm (NYY)''
Zero One Two
Seven
One Lakh
Thousand
PART-G-iii : 02- Fifty-Five
Seven
STORIED Thousand
Hundred
SECURITY From LT switchgear to PFI plant (without neutral, ECC and Six
653 40.b Rm 20.000 7783.001 and 155660.020
BUILDING conduit), 1C - 3 x 150 sqmm (NYY) Hundred
Eighty-
(ELECTRICAL and Sixty
Three
WORKS) point Zero
point Zero
Two
Zero One
One
PART-G-iii : 02-
Hundred
STORIED ''INSULATING TAPE: Supply and fixing of PVC insulating Twenty-
and
SECURITY tape. (UK / JAPAN or equivalent brand accepted / approved Five point
654 41.a Rm 5.000 25.001 125.005 Twenty-
BUILDING by the Engineer In Charge) Zero Zero
Five point
(ELECTRICAL a) ¾ '''' width PVC insulation tape (Nitto) (10 yards per reel)'' One
Zero Zero
WORKS)
Five
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 72/80
3/11/24, 2:55 PM View Form
Two Five
PART-G-iii : 02-
Hundred Thousand
STORIED
and Six
SECURITY
655 41.b ¾'' width PIB tape (25m per reel) Rm 20.000 282.001 Eighty- 5640.020 Hundred
BUILDING
Two point and Forty
(ELECTRICAL
Zero Zero point Zero
WORKS)
One Two
658 PART-G-iv : 02- 1 ''SPLIT TYPE AIR-COOLER: Supply, installation, testing & Each 4.000 201880.001 Two Lakh 807520.004 Eight Lakh
STORIED commissioning of split type air-cooler with inverter One Seven
SECURITY comprising condensing and evaporating units having Thousand Thousand
BUILDING (AIR following cooling capacity based on indoor temperature Eight Five
CONDITIONING 27º-30ºC DB / 19.5º-22ºC WB and outdoor temperature Hundred Hundred
SYSTEM WORKS) 35º-40ºC DB at high fan speed condition suitable for and Eighty and
installation & operation in tropicalized country like point Zero Twenty
Bangladesh & as per detailed specifications & standard as Zero One point Zero
mentioned below: Zero Four
(a). OUTDOOR UNIT / CONDENSING UNIT
(i). Type : Compact weather proof outdoor type condensing
unit
(ii). Compressor : Hermitically sealed reciprocating / rotary
compressor.
(iii). Refrigerant : Internationally accepted & recommended
and
most commonly used gas (CFC free)
(iv). Blower motor : Well balanced type direct driven
centrifugal
type blower fan
(v). Power supply :
(i). 200-250 V, single phase, 50 Hz. AC supply [up to 30000
BTU/HR]
(ii). 400-440 V 3-phase, 50 Hz. AC supply [above 30000
BTU/HR ]
(vi). Condensing pipe / coil : Made of copper
(vii). EER : Minimum 8.5 [ EER = BTU/HR ]
WATT
(viii). Others features :
(i). Well balanced in all respect having interlock with the fan
coil unit.
(ii). Compressor dully equipped with vibration isolator,
thermostatic & overload controls, magnetic contactors and all
other standard accessories complete.''
''(iii). Refrigerant copper pipe [From outdoor to indoor unit]
with thermal insulation, refrigerant charging arrangement etc.
[ Minm length10 mtr.]
(iv). Reqd. size PVC insulated & sheathed cable with ECC
through water grade PVC pipe from outdoor to indoor unit.
(b). INDOOR UNIT / FAN COIL UNIT
Features : (i). Direct expansion system fan coil unit with well
balanced direct driven centrifugal type fan.
(ii). Fancy & adjustable air circulating louver grill, removable
& washable type filter .''
''(iii). Condensing water drain out PVC flexible pipe with
necessary insulation
(iv). Thermostatic switch and remote control switch.
(c). Standard : Major component shall be manufactured as
per
relevant international standard & code.
(d). Documents : 01. Manufacturing company shall have the
following certificate :
(i). ISO-9001, 2008
(ii). CE / UL certification
Warranty :
The bidder should provide the guaranty of compressor for at
least 2 years & free service with spares for 2 years from the
date of commissioning & it should be obtained from the air
cooler selling agency. Any brand manufactured or assembled
in JAPAN / MALAYSIA / SOUTH KOREA / TAIWAN /
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 73/80
3/11/24, 2:55 PM View Form
THAILAND / USA / EU countries accepted / approved by the
Engineer in accordance with fulfillment of the above
specifications and having relevant certificates as mentioned.
Capacity : 28000-30000 BTU/HR a)Wall mounted (Inverter
Type) ''
Two
Thirteen
PART-G-iv : 02- Thousand
Thousand
STORIED Two
Six
SECURITY ''Air Diffuser With Damper : Hundred
660 2.2 Each 6.000 2268.001 13608.006 Hundred
BUILDING (AIR a) 150x150 mm'' and Sixty-
and Eight
CONDITIONING Eight point
point Zero
SYSTEM WORKS) Zero Zero
Zero Six
One
''VENTILATION FAN :
Supply, installation, testing & commissioning of Fan including
non return damper with all necessary accessories and Eleven Eleven
PART-G-iv : 02-
fittings, Fixing for commissioning of the equipment including Thousand Thousand
STORIED
all electrical & Civil works as follows technical specification, AND AND
SECURITY
661 3.1 drawing and time to time site instruction from Engineer-in- Each 1.000 11043.001 Forty- 11043.001 Forty-
BUILDING (AIR
charge. Country of Origin: USA/UK/ EU/Japan .Country of Three Three
CONDITIONING
Manufacture : Malaysia. point Zero point Zero
SYSTEM WORKS)
Exhaust Ventilation Fan (Wall Type): Fan shall be Zero One Zero One
propeller/axial type
a) Capacity : 200 cfm, ESP 100 Pa''
Twelve Twenty-
PART-G-iv : 02- Thousand Four
STORIED Two Thousand
SECURITY Exhaust Ventilation Fan (Duct Type): Fan shall be centrifugal Hundred Five
662 3.2 Each 2.000 12270.001 24540.002
BUILDING (AIR duct type Capacity : 200 cfm, ESP 100 Pa and Hundred
CONDITIONING Seventy and Forty
SYSTEM WORKS) point Zero point Zero
Zero One Zero Two
''Fire Extinguisher:
Dry chemical powder type : Supply & fixing the following
capacities multi purpose ABC dry chemical powder stored
pressure type with manometer system fire extinguisher
suitable for repeated use complete with wall bracket, CO2 Two Seventeen
cartridge, easy refilling system etc. as per sample accepted Thousand Thousand
PART-G-v : 02-
& approved by the Engineer. Four Three
STORIED
Mono Amonium Phosphate based 40% ABC dry chemical Hundred Hundred
SECURITY
664 1 agent & has a moisture-proof, anti-caking properties. Each 7.000 2473.001 and 17311.007 and
BUILDING (FIRE
Working pressure : 12 BAR minimum & Test pressure : 25 Seventy- Eleven
FIGHTING
BAR minimum. Proper fire rating (as per NFPA 10) according Three point Zero
WORKS)
to the capacity of the extinguisher. Manufacturerer certificate point Zero Zero
shall have to be submitted if needed. Also sample of the dry Zero One Seven
chemical powder will be tested by the proper authority in
Bangladesh if needed.
Country of origin : CHINA / MALAYSIA
a) 5 Kg. capacity.''
''CARBON-DI-OXIDE TYPE :
Supply & fixing of the following capacities Carbon-di-Oxide
stored pressure type with manometer system fire
Four Twenty-
extinguisher suitable for repeated use complete with wall
PART-G-v : 02- Thousand Four
bracket, CO2 cartridge, easy refilling system etc. as per
STORIED Nine Thousand
sample accepted & approved by the Engineer in Charge.
SECURITY Hundred Seven
665 2 Working pressure : 12 BAR minimum & Test pressure : 25 Each 5.000 4946.001 24730.005
BUILDING (FIRE and Forty- Hundred
BAR minimum. Proper fire rating (as per NFPA 10 / BS / EN)
FIGHTING Six point and Thirty
according to the capacity of the extinguisher. Manufacturer's
WORKS) Zero Zero point Zero
certificate shall have to be submitted if needed. Also sample
One Zero Five
of the Carbon-di-Oxide will be tested by the proper authority
in Bangladesh if needed.
a) 5 Kg. capacity.''
Three
One
Thousand
PART-G-v : 02- Thousand
Six
STORIED ''FIRE BALL : Eight
Hundred
SECURITY Supply of 1.25 Kg Fireball with bracket filled with Non-Toxic Hundred
666 3 Each 2.000 1841.001 3682.002 and
BUILDING (FIRE Mono Ammonium Phosphate of minimum 40 grade (fire class and Forty-
Eighty-
FIGHTING C).'' One point
Two point
WORKS) Zero Zero
Zero Zero
One
Two
667 PART-G-v : 02- 4 ''FIRE BLANKET : Each 10.000 1411.001 One 14110.010 Fourteen
STORIED Supply and fixing of fire proof emergency Fire Blanket made Thousand Thousand
SECURITY of fire glass cloth . Dimension of the blanket should be Four One
BUILDING (FIRE minimum 6' × 6' . Working temperature is minimum 550 0 C.'' Hundred Hundred
and and Ten
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 74/80
3/11/24, 2:55 PM View Form
FIGHTING Eleven point Zero
WORKS) point Zero One
Zero One
''Fire hydrant unit (1½'''' dia) : Each 1½'''' dia fire hydrant unit
Fourteen Twenty-
shall be complete with the following components and
Thousand Eight
PART-G-v : 02- accessories.
Four Thousand
STORIED a) Hose angle valve : 1½'''' dia : Supply and installation of
Hundred Nine
SECURITY hose angle valve / landing valve of 1½'''' (40mm) shall be
668 5 Each 2.000 14479.001 and 28958.002 Hundred
BUILDING (FIRE made with brass / bronze with instantaneous female outlet.
Seventy- and Fifty-
FIGHTING The valve shall be UL Listed / FM approved and working
Nine point Eight point
WORKS) pressure shall not be less than 10kg/cm². Inlet shtall be
Zero Zero Zero Zero
threaded end type, shall be installed inside the hydrant
One Two
cabinet.''
Thirty
PART-G-v : 02-
Six Thousand
STORIED
Hundred Three
SECURITY
672 8.b 40 mm (1½ inch) dia, wall thickness: 3.7mm Rft 50.000 607.001 and Seven 30350.050 Hundred
BUILDING (FIRE
point Zero and Fifty
FIGHTING
Zero One point Zero
WORKS)
Five
674 PART-G-v : 02- 10 ''RELEASE CONTROL PANEL : Each 1.000 92029.001 Ninety- 92029.001 Ninety-
STORIED Providing & fixing Release control panel for gas suppression Two Two
SECURITY system complete with battery and all other necessary Thousand Thousand
BUILDING (FIRE accessories. Each unit shall be UL Listed/ FM Approved. AND AND
FIGHTING a) 2 Zone'' Twenty- Twenty-
WORKS) Nine point Nine point
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 75/80
3/11/24, 2:55 PM View Form
Zero Zero Zero Zero
One One
One
Nine
PART-G-v : 02- Thousand
''RELEASE CONTROL PANEL : Thousand
STORIED Eight
Providing & fixing Release control panel for gas suppression Two
SECURITY Hundred
675 11.a system complete with battery and all other necessary Each 5.000 1841.001 9205.005 Hundred
BUILDING (FIRE and Forty-
accessories. Each unit shall be UL Listed/ FM Approved. and Five
FIGHTING One point
a) 2 Zone'' point Zero
WORKS) Zero Zero
Zero Five
One
Four
Two
PART-G-v : 02- Thousand
Thousand
STORIED Four
Two
SECURITY Hundred
676 11.b 19 mm dia (3/4 Inch)360o Each 2.000 2209.001 Hundred 4418.002
BUILDING (FIRE and
and Nine
FIGHTING Eighteen
point Zero
WORKS) point Zero
Zero One
Zero Two
681 PART-G-v : 02- 15.b 2C-2.5 sqmm (FPLR/ FPLP/ FPL ) cable with 2.5 sqmm (FR) Rm 100.000 313.001 Three 31300.100 Thirty-One
STORIED ECC wire through PVC pipe of minimum inner dia 25 mm Hundred Thousand
SECURITY having wall thickness of 1.5 mm and Three
BUILDING (FIRE Thirteen Hundred
point One
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 76/80
3/11/24, 2:55 PM View Form
FIGHTING point Zero
WORKS) Zero One
Three Three
Thousand Thousand
PART-G-v : 02-
Six Six
STORIED Supply and installation of ''Exit light'' complete with
Hundred Hundred
SECURITY rechargeable battery and charge light and other necessary
683 17 Each 1.000 3681.001 and 3681.001 and
BUILDING (FIRE accessories suitable for AC / DC power supply (220V single
Eighty- Eighty-
FIGHTING phase) as per NFPA 101
One point One point
WORKS)
Zero Zero Zero Zero
One One
685 PART-G-vi : 02- 2 ''Supply and fixing of 2 MP, PTZ Camera (including lens, Each 2.000 383448.001 Three 766896.002 Seven
STORIED bracket, housing) of following technical specification or Lakh Lakh
SECURITY equivalent : Eighty- Sixty-Six
BUILDING (CC TV Image Sensor : 1/2.8'''' Progressive Scan CMOS , 2 Three Thousand
SYSTEM WORKS) Megapixel (minimum) Thousand Eight
Min. Illumination : At least Color: 0.0186 lux /F1.6), B/W: 0 Four Hundred
Lux with IR Hundred and
Shutter Speed : 1/3 s to 1/30,000 s and Forty- Ninety-Six
Wide Dynamic Range : 120 dB or above Eight point point Zero
Focal Length : At least 4.8 to 135 mm Zero Zero Zero Two
Optical Zoom : 30 x or above One
Digital Zoom : 12x
Focal Length & FOV : horizontal FOV 58.3°?2.6°,
Aperture : At least F1.6 - F4.4
Supplement Light Type : IR
IR Range : minimum 180 m
Pan/Tilt range : 0°~360° ; -15°~90° or -90° to 20°( auto flip)
Pan speed : preset speed :240°/s
Tilt speed : preset speed :160°/s
Presets : minimum 256
Max. Resolution : 1920x1080 or above
Main Stream : Main Stream: 1920x1080 (1 fps?25 fps) with
at least 1 sub-stream
Video Compression : H.265/H.264/MJPEG
Audio Sampling Rate : 8 kHz/16 kHz/32 kHz/44.1 kHz/48
kHz
Audio Compression :
G.711ulaw/G.711alaw/G.722.1/G.726/MP2L2/PCM/MP3/AAC
API : ONVIF (Profile S/Profile G/Profile T)
Protocols : TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS,
DDNS, RTP, RTSP, NTP, UPnP, SMTP, IGMP, 802.1X, QoS,
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 77/80
3/11/24, 2:55 PM View Form
IPv4, IPv6, UDP, PPPoE, ARP, SNMP etc.
SNR : ≥ 56 Db
Day/Night Switch : Day, Night, Auto, Schedule
Alarm : 1 input, 1 output
Audio : 1 input (line in), 1 output (line out)
On-Board Storage : Micro SD
Ethernet Interface : RJ-45 (10/100 Base-T)
Basic Event : Motion detection ,video tampering alarm
Power Supply : DC 12V /24 V /AC 24 V (±30%), PoE (802.3
at /af)
Power Consumption : maximum 25 Watt
Camera Material : Metal''
''Operating Temperature and humidity : 'Temperature :-43 ºC
to +50 ºC for continuous
Operation Humidity: 5% to 90% RH non condensing
Protection : IP 66 or above
Certifications : CE,UL,FCC
Country of origin : USA/Japan /UK/ EU countries or
equivalent accepted/ approved by the Engineer in Charge.''
689 PART-G-vi : 02- 6 ''Access Switch Type-3 (24 ports POE and 4 x 1G SFP slots) Each 1.000 186422.001 One Lakh 186422.001 One Lakh
STORIED Supply, installation, testing & commissioning of Access Eighty-Six Eighty-Six
SECURITY Switch (24 ports POE and 4 x 1G SFP slots) under the Thousand Thousand
BUILDING (CC TV following specifications & features or equivlent as per Four Four
SYSTEM WORKS) direction of the Engineer in charge. Hundred Hundred
Technical Specifications: Quality: ISO 9001/9002 for and and
manufacturer, FCC Class A/B for quality assurance Twenty- Twenty-
Enclosure Type: 1 RU, 19-in. Rack Mountable with Rack Two point Two point
Mounting Kit Architecture: Proposed switch should be Zero Zero Zero Zero
enterprise grade switch with x86 based CPU architecture. One One
Performance Feature:
The Switch should have 24 x 10/100/1000 Base-T PoE ports
and 4 x 1G SFP slots Switch should have minimum 370W for
PoE power with additional secondary power supply. The
switch should be able to deliver PoE power to end devices
without waiting for the switch OS to load fully.
Switch should support Software Defined Network (SDN) and
can be integrated with SDN controller if required in future.
Switching Performance : The Switch should have 24 ports
POE and 4 x 1G SFP slots slots. The switch should support
Following 56 Gbps switching capacity and 41.66 Mbps
Forwarding rate.''
''Switch should have minimum 2GB RAM and 4 GB Flash.
The switch should support 16000 MAC Addresses and 4096
VLAN IDs.
Switch should have slot/ports (excluding uplinks ports) for
minimum 120 Gbps of stacking bandwidth with dedicated
stacking ports and cables with minimum 8 switch in stack
Switch should be able to support 3000 IPV4 & 1500 IPV6
routing entries from day-1
Switch should support minimum 512 Switched Virtual
Interfaces.
Switch Layer 2 Services: The switch should support
Automatic Negotiation of Trucking Protocol, to help minimize
the configuration & errors. The switch should support IEEE
802.1Q VLAN encapsulation.
Switch should support IPv4 and IPv6The Switch should be
able to discover (on both IPv4 & IPv6 Network) the
neighboring device giving the details about the platform, IP
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 78/80
3/11/24, 2:55 PM View Form
Address, Link connected through etc., thus helping in
troubleshooting connectivity problems.
The switch should support Spanning-tree root guard to
prevent other edge switches becoming the root bridge. ''
See the Technical Specification.
Six Three
PART-G-vi : 02-
Hundred Thousand
STORIED Supply of proximity card of 13.56 MHz or 125 KHz Transmit
and AND
692 SECURITY 9 frequency with both side printable feature, accepted/ Each 5.000 614.001 3070.005
Fourteen Seventy
BUILDING (CC TV approved by the Engineer-in-charge.
point Zero point Zero
SYSTEM WORKS)
Zero One Zero Five
Twenty-
''Supply and installation of Exit button of following Four
Four
PART-G-vi : 02- specification or equivalent- Thousand
Thousand
STORIED controlled by door controller- unlock the door when it is Nine
Five
694 SECURITY 11 pressed Each 5.000 4908.001 Hundred 24540.005
Hundred
BUILDING (CC TV Operating Voltage : 10-14 Vdc or 125-250 Vac and Eight
and Forty
SYSTEM WORKS) Operating Temperature : -20°C - +55°C point Zero
point Zero
Accepted /approved by the Engineer-in-charge.'' Zero One
Zero Five
Thirty
Six
''Supply and installation of break glass unit for emergency Thousand
Thousand
PART-G-vi : 02- door release of following specification or equivalent- Six
One
STORIED Double pole double throw contacts (NO,NC,COM) Hundred
Hundred
695 SECURITY 12 Resettable with key Each 5.000 6135.001 30675.005 and
and Thirty-
BUILDING (CC TV Status indicator Seventy-
Five point
SYSTEM WORKS) Embedded or surface mounting options Five point
Zero Zero
Accepted /approved by the Engineer-in-charge.'' Zero Zero
One
Five
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 79/80
3/11/24, 2:55 PM View Form
Seventeen Thirty-Five
''Supplying & Fixing of wall / pad mounted rack cabinet with
Thousand Thousand
PART-G-vii : 02- low noise, fan on top, 2 side door, cam lock, front door glass
Seven Five
STORIED with cam lock, 1 wall mounted power distribution unit, 6-way,
Hundred Hundred
SECURITY welded frame with epoxy power coating painted, reliable
698 3 Each 2.000 17792.001 and 35584.002 and
BUILDING structure, removable side panels, optional side locks, cable
Ninety- Eighty-
(SOUND SYSTEM entry on both top cover and bottom panel. (Foreign Made).
Two point Four point
WORKS) Model & sample to be approved by the Engineer in charge.
Zero Zero Zero Zero
a) Size: 600 x 450 x 635 mm or equivalent, 2 nos 4'' fan ''
One Two
Twenty-
Four
Crore
Sixty-Eight
Lakh
Grand
246845046.158 Forty-Five
Total:
Thousand
AND
Forty-Six
point One
Five Eight
This Bill of Quantities is Electronically Signed by Mr. Md Hossain on behalf of HOSSAIN CONSTRUCTION (PVT) LTD
https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=5043933&userId=49461&nture=Works&tenId=924961&procMtd=… 80/80