Renishaw RGH24 Installation Guide
Renishaw RGH24 Installation Guide
M-9541-9109-01-C
Scale application 5
End clamps 5
Limit switch 6
Output signals 7
Speed 7
Electrical connections 8
Output specifications 9
General specifications 10
Scale specifications 10
C
Renishaw plc declares that RGH24 complies with the applicable standards and regulations. The packaging of our products contains the following materials and can be recycled.
A copy of the EC Declaration of Conformity is available on request.
Packaging Component Material ISO 11469 Recycling Guidance
RoHS compliance
Compliant with EC directive 2011/65/EU (RoHS)
Further information The use of this symbol on Renishaw products and/or accompanying documentation indicates that the product
should not be mixed with general household waste upon disposal. It is the responsibility of the end user to
Further information relating to the RGH24 encoder range can be found in the RGH24 system
Data sheet (L-9517-9677). This can be downloaded from our website www.renishaw.com/encoder dispose of this product at a designated collection point for waste electrical and electronic equipment (WEEE)
and is also available from your local representative. This document may not be copied or reproduced to enable reuse or recycling. Correct disposal of this product will help to save valuable resources and prevent
in whole or in part, or transferred to any other media or language, by any means without the written potential negative effects on the environment. For more information, please contact your local waste disposal
prior permission of Renishaw. The publication of material within this document does not imply freedom service or Renishaw distributor.
from the patent rights of Renishaw plc.
Disclaimer
RENISHAW HAS MADE CONSIDERABLE EFFORTS TO ENSURE THE CONTENT OF THIS
DOCUMENT IS CORRECT AT THE DATE OF PUBLICATION BUT MAKES NO WARRANTIES
OR REPRESENTATIONS REGARDING THE CONTENT. RENISHAW EXCLUDES LIABILITY,
HOWSOEVER ARISING, FOR ANY INACCURACIES IN THIS DOCUMENT.
Chlorinated Methylated
CH3(CH2)5CH3 CH3CHOHCH3 CH3COCH3
Solvents Spirits
RGS20 – 100 mm
NOTE: Ensure self-adhesive
tape is on outside of bend.
13.5
3
(Yaw Tol. ±0.5°)
5.5 8 6 (RGS20-S) 3.8
0.3 6.3 (RGS20-P)
4.8
(Extent of mounting faces)
Mounting face
8.5
4.
0.6
4
>15 14
30 <10 2.2 8.7
0.5
F
0.2/100
F = axis of motion
13
RGS20 scale installation drawing (with limit switch actuator) Dimensions and tolerances in mm
>15 <10 10
30 2 8.5
0.5
F
0.2/100
F = axis of motion
13
NOTE: The surface roughness of the scale mounting surface must be ≤3.2 Ra. The parallelism of the scale surface to the axis of motion (readhead rideheight variation) must be within 0.05 mm.
m
6 Begin to remove the backing paper from the scale and insert scale into the applicator up to the ‘START’ point
m
15
(as shown). Ensure backing tape is routed under the splitter screw.
7 Apply finger pressure to the scale at the ‘START’ point,
using a clean lint-free cloth, to ensure scale end
‘START’ point
adheres well to substrate.
3 The end clamp features two small regions 4 Immediately position end clamp over the
M2.5 mounting holes of contact adhesive. These will temporarily end of the scale.
hold the end clamp in position while the glue Allow 24 hours at 20 °C for full cure.
cures. Remove the backing tape
from either side.
8 Slowly and smoothly move the applicator through the entire axis of travel, ensuring the backing paper is
pulled manually from the scale and does not catch under the applicator.
Scale
Splitter screw
Backing paper
Roll
0° ± 1°
Limit switch
A limit switch signal is output when the readhead sensor passes over the magnetic actuator.
NOTE: RGH24 readheads are available with reference mark or limit switch detection.
For reliable operation, the set-up LED should be GREEN when readhead is moved along the full axis travel.
Select output at order.
The JST version of the RGH24 has an LED repeater signal that can be used in cases where the LED is not visible.
NOTE: Limit switch output is not available with analogue RGH24, or options 60, 61 and 62 of the
*Remote LED will continuously flash Red when signal <20%
digital RGH24.
0V White 1 10 2, 9 D (5 µm ) 8
Encoder velocity (m/s)
Incremental signals + Green 2 8 14 X (1 µm ) 5 x 4 safety factor
A Resolution (µm)
- Yellow 6 7 6 Z (0.5 µm) 3
+ Blue 4 2 13
B
- Red 8 1 5
Clocked output readheads
Reference mark / Z+ / Q- Pink 3 5 12
The RGH24W, Y, H, I and O readheads are available with a variety of different clocked outputs.
limit switch Z- / Q+ Grey 7 6 4 Customers must ensure they comply with the lowest recommended counter input frequency.
Shield Inner – 9 N/A 15
Standard Maximum speed (m/s) Lowest
Outer – Case N/A Case JST connector
connector Head type recommended
options
Remote LED driver Green – N/A 4 N/A options counter input
(Z) W Y H I O
(A, D and F) frequency (MHz)
Red – N/A 3 N/A (0.2 µm ) (0.1 µm ) (50 nm) (20 nm) (10 nm)
60 – – 3.0 – – – 50
RGH24B 1Vpp analogue 61 – 3.0 1.6 – – – 20
62 – 1.3 0.8 – – – 10
9 way D type JST 15 way D type
Function Signal Colour 30 35 – 0.7 0.35 0.13 0.65 12
(A) (Z) (L)
31 36 – 0.5 0.25 0.09 0.045 8
Power 5V Brown 5 9 4, 5
32 37 0.7 – – – – 6
0V White 1 10 12, 13 33 38 0.5 0.25 0.12 0.04 0.02 4
Incremental signals + Green 2 8 9 NOTE: Maximum speeds of clocked output variants assume 3 m maximum cable length and minimum 5 V supply
V1
- Yellow 6 7 1 at readhead connector.
+ Blue 4 6 10
V2
- Red 8 5 2
Analogue readheads
Reference mark + Pink 3 2 3
V0 RGH24B – 4 m/s (-3dB)
- Grey 7 1 11
Shield Inner – 9 N/A 15
Outer – Case N/A Case
52 16
52 16
31 40
9 pin D type plug (Termination code A) 15 pin D type plug (Termination code D, L)
Output
signals
0V
Outer shield
IMPORTANT: The outer shield should be connected to the machine earth (Field Ground). The inner shield should be connected
to 0 V. Care should be taken to ensure that the inner and outer shields are insulated from each other. If the inner and outer shields
are connected together, this will cause a short between 0 V and earth, which could cause electrical noise issues.
A B Z Q-
220 pF
0V
Incremental= 2 channels A and B in quadrature (90° phase shifted) Incremental 2 channels V1 and V2 differential sinusoids in quadrature (90° phase shifted)
Signal period P 20 µm
P S
Model
(µm) (µm)
Resolution S RGH24D 20 5
RGH24X 4 1
RGH24Z 2 0.5 0.6 to 1.2 Vpp with green LED
RGH24W
(V1 +) - (V1-)
0.8 0.2 indication and 120 Ω termination.
RGH24Y 0.4 0.1 90°
A RGH24H 0.2 0.05
B RGH24I 0.08 0.02 (V2 +) - (V2-)
RGH24O 0.04 0.01
Reference= Reference
Differential pulse V0 - 18° to 108°.
Synchronised pulse Z, duration equal to the resolution. Duration 126° (electrical).
0.8 to 1.2 Vpp
Repeatability of position (uni-directional) maintained within ±10 Repeatability of position (uni-directional) maintained
Z °C from installation temperature and for speed <250 mm/s. within ±10 °C from installation temperature and for
speed <250 mm/s.
(V0+) - (V0-)
-18° 108°
Actuation device: A-9541-0037 or A-9531-0250 0° Actuation device: A-9531-0037 or A-9531-0250
Q
NOTE: RGH24 readheads are available with reference mark
or limit switch detection. Select output at order.
Length of actuating
Actuation device: A-9541-0040 or A-9531-0251
magnet
NOTE: Limit output not available for readheads with option 60, 61 and 62.
Alarm
3-state alarm
Incremental channels forced open circuit for >20 ms when signal too low for reliable operation.
For RGH24W, Y, H, I and O only, incremental channels forced open circuit for >10 ms when signal
too low or speed too high for reliable operation.
RENISHAW® and the probe symbol used in the RENISHAW logo are registered trade marks
of Renishaw plc in the United Kingdom and other countries.
*M-9541-9109-01*
apply innovation and names and designations of other Renishaw products and technologies
are trade marks of Renishaw plc or its subsidiaries.
2001-2018 Renishaw plc All rights reserved Issued 0118