Countermeasure Against Malfunction of MFD Connection
Countermeasure Against Malfunction of MFD Connection
: FSN220004
MARINE Date : February 18, 2022
Person in-charge :
Y. Imada, Manager & Group Leader
Marine communication group
Marine Electronics Division
Service News
Information ✓ Request for work
4 Details
4.1 General
We have revised the CMN-2800 RF UNIT of the JHS-800S Marine VHF radiotelephone and the software to control the new unit as
mentioned on JD-1406-22 Technical Information. However it has been found that the following serial number's products that are
connected to the MFD and operated from it, have experienced a VHF control failure screen that appears on the MFD. Therefore, for
these products, perform the countermeasure as given below.
Serial number: BK39091 - BK39195, BK39206 - BK39289, and BK39306 - BK39405 with software maintenance number 00.92B
From: Old software version SVer. 1.03/ Maintenance number MNo. 00.92B
To: New software version SVer. 1.03/ Maintenance number MNo. 00.92D
4.3 Others
The software upgrade procedure is as follows.
1) Download the objective software "JHS-800S_0103092D.zip" and "NCM-980_0103092D.zip" on the MSweb homepage.
2) Upgrade the software of the objective equipment referring the attached "JD210928D JHS-800S Software Upgrade Procedures".
3) Fill in the attached "7ZPJD0744A VHF JHS-800S Maintenance Record" and send it via E-mail to the address given on the form.
*
JD210928D
To upgrade the software of the JHS-800S Marine VHF radiotelephone and/or the NCM-980 Controller using the
LAN port on the back of them and PC, follow the procedure below. Additionally, If multiple NCM-980s are
installed, upgrade all of the NCM-980 respectively.
1. Upgrade Preparations
Prepare the following items to upgrade the software.
PC environment Windows XP/Vista/7/10 operating system, with more than 1 MB of
available space on the hard disk, and a LAN port. NET Framework
2.0 must be installed.
Cable for upgrade LAN cable (Cat-5 or more)
Target software JHS-800S_xxxxxxx.jrc for Marine VHF radiotelephone
NCM-980_xxxxxxx.jrc for controller
Upgrade tool software (PC app.) Distribution file "CYC762_UpdateTool_JHS800S.zip"
Note) Common software for such INM-C and/or AIS.
To install: Unzip the above files and save them in the same folder.
To uninstall: Delete all of the installed files.
1
JD210928D
2. Upgrade Procedure
This section explains how to connect a computer (hereafter PC) and start the tools to do an upgrade.
1) Connect JHS-800S or NCM-980 and the PC as shown below. And also, directly connecting JHS-800S or
NCM-980 and the PC with LAN cable is available.
2
JD210928D
9) Select the LWE network from the [Network] list. After that the IP address and subnet mask appear in the
PC IP/Mask field. If the first three octets of the target unit IP address are not correct, set it manually.
Additionally, regarding the fourth octet of the PC IP, set the adequate number so that the PC IP address is
different from the IP addresses of JHS-800S and/or NCM-980 described below.
10) In the [Adapter] list, select the network adapter that is connected to the targeted device.
3
JD210928D
11) Click the [Set IP] button to temporarily change the IPv4 setting to the values in IP and Mask.
After that the popup showing "IP Setting is OK" appears as follows.
13) Click the [Get Version] button to get the current maintenance number of the software.
After getting it, the following "OK" popup is appeared.
4
JD210928D
15) Click the [Browse...] button to open the file selection dialog box.
Select the new software file from the file selection dialog box.
5
JD210928D
16) The selected file information are indicated on the [Version] and [Information] field.
6
JD210928D
18) When the upgrade is complete, the target unit restart automatically. And the following popup showing
"Update completed" and the new/old versions is displayed.
19) Click the [X] button at the top of the screen to close the application.
20) After restarting the equipment, touch the CODE INPUT button in the main menu and input "6926" to start
the field maintenance mode.
21) From the main menu, touch the [USER MENU] [MAINT] [S/W VER] buttons to show the following
screen.
22) Touch the [MAINT NUMBER] button and confirm that the maintenance number is upgraded correctly and
the software upgrade is complete.
23) Turn off the power and then back on again to start the user mode.
7
JD210928D
1) From the main menu in the field maintenance mode, touch [MAINT MENU] > [PRIMAL SET] > [COMM SET]
buttons to open the [2/2] ETHERNET SET menu.
2) Set the IP addresses and the SFI (System Function ID) of the JHS-800S and/or NCM-980 on the menu of the
[2/2] ETHERNET SET referring the following table.
8
7ZPJD0744A
保守
船名
Name of Vessel
識別番号
MMSI No.
総合番号
BK
JHS-800S Serial No.
機器名 項目 交換前 交換後
Unit name Item Old New
国際 VHF 無線電話装置 機器製造番号
BK BK
Marine VHF Unit serial number
Radiotelephone ソフトウェアメンテナンスナンバー
Ver. Ver.
JHS-800S Software maintenance number
機器製造番号
コントローラ 1 BJ BJ
Unit serial number
Controller 1
ソフトウェアメンテナンスナンバー
NCM-980 Ver. Ver.
Software maintenance number
機器製造番号
コントローラ 2 BJ BJ
Unit serial number
Controller 2
ソフトウェアメンテナンスナンバー
NCM-980 Ver. Ver.
Software maintenance number
機器製造番号
コントローラ 3 BJ BJ
Unit serial number
Controller 3
ソフトウェアメンテナンスナンバー
NCM-980 Ver. Ver.
Software maintenance number
機器製造番号
コントローラ 4 BJ BJ
Unit serial number
Controller 4
ソフトウェアメンテナンスナンバー
NCM-980 Ver. Ver.
Software maintenance number
工事日
Service Date
港
Service Port
オーダ
Service Order
代理店
Service Agent
作業者
Service Engineer
作業後に動作(送受信など)が正常であることを確認
YES NO
The normal operation check after work
装置は装備モードから通常モードに戻しましたか?
YES NO
Did you return to normal mode from maintenance mode?
備考
Remarks
1/1
JHS-800S Software revision list 7ZPJD0784
1. Added the Block channel function (inc. maximum 999 waypoints registration
using Web browser)
2. Added the auto channel change on/off for DSC reception and GPS state display
for MED requirements.
3. Added the registration data of the user menu to the data backup and restore
2021/2/17 1.02 0.89G function using web browser. FSN210002 BK38655 ~
4. Following bug fix
BT pairing NG after initialization/ False-positive Loop NG of self diagnosis/
Getting priority error/ User-unfriendly web browser operation/
Backup data restoration failure
1. Upgraded to SIG approved version for the bluetooth type speaker mic.
2. Modified the phenomenon that when pairing the speker mic the search result list
screen always shows the previous used BT device at the first line.
3. Modified the malfunction that when resending distress alert automatically in the
distress mode, the nature of distress always becomes UNDESIGNATED.
4. Added the sentences except ZDA such as GGA, GNS, GLL, RMC from a
2020/1/23 1.01 0.83 navigation system to update the time for the internal system clock. FSN200002 BK36626 ~
5. Modified the malfunction that during dual watch or triple watch if pressing PTT,
the transmission is rarely made on the channel other than the displaying channel.
6. Shortened the squelch closing time to reduce noise at end of radiotelephone
reception.
7. Made minor bug fixes of the maintenance mode menu.
Modification of the high temperature alarm detection for the integrate console:
2019/8/29 1.01 0.79 90 degree C => 87 degree C --- BK35236 ~
1. Added China dedicated mode. (TX pwr:10W/1W, Prohibition of some ITU ch)
2. Made minor bug fixes.
2022/1/13 1.03 0.92B JD-1406-22 -
1. Added the Block channel function (inc. maximum 999 waypoints registration
using Web browser)
2. Added the auto channel change on/off for DSC reception and GPS state display
for MED requirements.
3. Added the registration data of the user menu to the data backup and restore
2021/2/17 1.02 0.89G function using web browser. FSN210002 BJ40500 ~
4. Following bug fix
BT pairing NG after initialization/ False-positive Loop NG of self diagnosis/
Getting priority error/ User-unfriendly web browser operation/
Backup data restoration failure
1. Upgraded to SIG approved version for the bluetooth type speaker mic.
2. Modified the phenomenon that when pairing the speker mic the search result list
screen always shows the previous used BT device at the first line.
3. Modified the malfunction that when resending distress alert automatically in the
distress mode, the nature of distress always becomes UNDESIGNATED.
4. Added the sentences except ZDA such as GGA, GNS, GLL, RMC from a
2020/1/23 1.01 0.83 navigation system to update the time for the internal system clock. FSN200002 -
5. Modified the malfunction that during dual watch or triple watch if pressing PTT,
the transmission is rarely made on the channel other than the displaying channel.
6. Shortened the squelch closing time to reduce noise at end of radiotelephone
reception.
7. Made minor bug fixes of the maintenance mode menu.
Modification of the high temperature alarm detection for the integrate console:
2019/8/29 1.01 0.79 90 degree C => 87 degree C --- -