Footing 1 Checked by Approved by

Subject (Type I)
-
Building Cargo
Design of Isolated Footing with Vertical Load Only - According to ACI 318M-99
Bearing Capacity = 35.00 t/m2
Concrete Cylinder Strength (f ' c ) = 350 kg/cm2 Reif. Steel Ult .Strength (f y ) = 4200 kg/cm2
Soil density (Gs) = 1.80 t/m3

Footing ID: f2
Ultimate Column Load = 200.00 t A1 = 0.21 m2
Service Column Load = 133.33 t A2 = 2.85 m2
200.00 t
Column Dimensions
Length = 70.00 cm
Width = 30.00 cm
trc
Footing Dimensioning tpc
Required Bearing Area on soil = 4.19 m2
tpc Lrc tpc

Plain Concrete Dimensions Chosen Plain Concrete Dimensions Reinforced Concrete Dimensions
Length = 2.30 m Length = 2.90 m Length = 2.90 m
Width = 1.90 m Width = 2.50 m Width = 2.50 m
Thickness = 0.10 m Thickness = 0.10 m Thickness = 0.60 m
Depth = 0.55 m
Final stress under P. C. footing = 18.83 t/m2 (Safe)
Final stress under R. C. footing = 18.81 t/m2 (Safe)
Nominal Bearing strength of column = 437.33 t (Safe)
Nominal Bearing strength of footing = 874.65 t (Safe)

Footing Reinforcement I
Bearing Pressure (Ultimate Load) = 28.17 t/m2 tpc
Max. Ult. Bending Moment (Sect. I-I) = 31.76 m t/ m' II
Max. Ult. Bending Moment (Sect. II-II) = 31.76 m t/ m'
Wrc
Bar sizes to be chosen are ( 12, 16, 20, 22, 25, 32, 40)
As I-I = 15.59 cm2 As I-I(chosen) = 8 f 16 / m' tpc
As II-II = 15.59 cm 2
As II-II(chosen) = 8 f 16 / m'
r = 0.08 rb tpc Lrc tpc

Check Wide Beam Action ( Shear )


Area subject to Shear stress = 1.38 m2
Maximum Allowable Footing Resistance For Shear = f Vn = 0.85 * (( f ' c) ^ 0.5 * b * d / 6)= 115.24 t
Force Acting On Footing Due To Shear (Vus) = 38.74 t < 115.24 t (Safe)

Check Two Way Action (Punching)


Area subject to Punching shear = 6.19 m2
Perimeter Resisting Punching shear (bo) = 4.20 m
Maximum Allowable Footing Resistance to Punching is the Least of :
1- 0.85*((f ' c )^0.5*bo*d)/3 = 387.21 t
2- 0.85*((1+2/bc )*(f ' c )^0.5*bo*d/6) = 359.55 t
3- 0.85*(((as *d/bo)+2)*(f ' c )^0.5*bo*d/12) = 700.66 t

where, b c is the ratio of long side to short side of the column, concentrated load or reaction area
and, a s is 40 (for interior columns)

Punching Force acting on Footing (Vps) = 174.33 t < 359.55 t (Safe)


ACI-Foot-VL load - Rev. 1.0 1/1 5/7/2024