0% found this document useful (0 votes)
14 views17 pages

E T-90series Reva

The document provides information on type code designations and specifications for box transducers. It describes the marking systems for identifying transducer types, inputs, housing dimensions and circuit types. Standard specifications are also listed, such as tolerance, temperature influence, response time, overload protection and insulation ratings.

Uploaded by

sombatmhm
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views17 pages

E T-90series Reva

The document provides information on type code designations and specifications for box transducers. It describes the marking systems for identifying transducer types, inputs, housing dimensions and circuit types. Standard specifications are also listed, such as tolerance, temperature influence, response time, overload protection and insulation ratings.

Uploaded by

sombatmhm
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

§ BOX TRANSDUCER §

TYPE CODE DESIGNATION

■ TYPE CODE DESIGNATION

● SMALL SIZED AC TRANSDUCER

TT2-90A series (1) TT2 (2) A - (3)

(1) Kind of input (2) Kind of outer case and its dimensions

Mark Kind of input Dimensions (mm)


Mark Material of outer case
A or AE AC current Length × Width × Height

V or VE AC voltage 91 Fire-retardant ABS resin 120×40×130

W AC power 92 Fire-retardant ABS resin 120×56×130

WV Reactive power (3) Kind of circuit


S V-V phase angle
Mark Kind of circuit
P V-I phase angle
12 Single phase 2 wire
SP Power factor
13 Single phase 3 wire
F Frequency
33 3 phase 3 wire
34 3 phase 4 wire

● AC TRANSDUCER

TT2-80A series (1) TT2 (2) A (3) – (4)

(1) Kind of input

Mark Kind of input


Dielectric strength voltage
AE AC current
FAE Power flow current AC2,000V (50/60Hz) for 1 min,

VE AC voltage between input and output

W AC power (3) For the use of cycle control


FWV Reactive power (power flow)
Mark Kind
FSP Power factor (power flow)
No mark General circuit
MDA Maximum demand
C Cycle control
MDV Maximum indication voltage
(2) Kind of outer case and its dimensions (4) Kind of circuit

Dimensions (mm) Mark Kind of circuit


Mark Material of outer case
Length × Width × Height 12 Single phase 2 wire
82 Fire-retardant ABS resin 120× 56×130 13 Single phase 3 wire
83 Fire-retardant ABS resin 120×110×130 33 3 phase 3 wire
34 3 phase 4 wire
§ BOX TRANSDUCER §
TYPE CODE DESIGNATION

● SENSOR TRANSDUCER

TT-A series (1) TT (2) - (3) A

(1) Kind of input (2) Dielectric strength voltage

Mark Kind of input Dielectric strength voltage


Mark
H Thermoelectric temperature (50/60Hz)
RH Resistance temperature Non-insulated between input
No number
R Potentiometer and output
G Revolution-speed (Frequency proportion) AC2,000V for 1 min. between
2
GV Revolution-speed (AC voltage proportion) input and output

(3) Kind of outer case and its dimensions

Dimensions (mm)
Mark Material of outer case
Length × Width × Height
82 Fire-retardant ABS resin 120× 56×130
83 Fire-retardant ABS resin 120×110×130

● SIGNAL TRANSDUCER

T-A series (1) (2) - (3) A

(1) Kind of conversion (2) Dielectric strength voltage

Mark Kind of conversion Mark Dielectric strength voltage (50/60Hz)


ADTT Adding No number Non-insulated between input and output
SCTT Scaling (option) 2 AC2,000V for 1 min. between input and output
VF Analog/Pulse
SE Input switching

(3) Kind of outer case and its dimensions

Dimensions (mm)
Mark Material of outer case
Length × Width × Height
82 Fire-retardant ABS resin 120× 56×130
83 Fire-retardant ABS resin 120×110×130
§ BOX TRANSDUCER §
COMMON STANDARD SPECIFICATION

■ COMMON STANDARD SPECIFICATIONS


● HIGH QUALITY / HIGH RELIABILITY ● PCB TREATMENT
Highly reliable electronic parts are adopted. Aging In order to reinforce insulation resistance
test of each part as well as burn-in aging test of the stability of PCB surfaces and prevent the
product under a high temperature is implemented. surfaces from insulation deterioration, B side
of the PCB was cleaned and coated with high
● OUTPUT LIMITER CIRCUIT
humidity resistant varnish after parts
Even if an excessive input is applied, the product
installation.
confines the output to about 1.5 times of rating and
protects the output side equipments.

TT2-80A series STANDARD SPECIFICATION

Item Specification
Tolerance % against output span. See [Specifications]
Influence of temperature 23±20℃ tolerance %
No display: 1/2 of tolerance % at 45-65Hz
Influence of frequency
Rated Hz display: 1/2 of tolerance at ±5% of rating
Characteristics In conformity with the classifications of JIS C 1111-1989 in tolerance
Time it takes to fall within ±1% of the final steady-state value
Response time
when applied a stepped input. ≦1 sec.
Output ripple ≦1% P-P against output span
External adjustment of output ±5% adjustable
Auxiliary supply AC110V or AC220V ±15% (50/60Hz)
2 times of rated voltage (10 sec.), 1.2 times (Continuity)
Over voltage
Auxiliary supply of isolator: 1.5 times 10sec.

40 times of rated current (1 sec.), 20 times (4 sec.) 10 times (16 sec.), 1, 2 times
Over current
(Continuity), (Signal transducer: 10 times 5 sec.)

≧50MΩ at DC500V between input terminal, output terminal,


Insulation resistance
(auxiliary supply terminal) and outer case (earth)
AC2,000V (50/60Hz) for 1 min. between input terminal, output terminal,
Withstand voltage
(auxiliary supply terminal) and outer case (earth)
Between electric circuit and outer case (earth) 5kV 1.2/50µs
Impulse withstand voltage
positive/negative polarity 3 times each
See [Kind of outer case] in [Type code designation]
Appearance color
Black (N 1.5)
Operating
-10 - +55℃, 30 - 85%RH
temperature/humidity range
Storage temperature range -40 - +70℃
§ BOX TRANSDUCER §
COMMON STANDARD SPECIFICATION

■ DIMENSIONAL EXAMPLE of MULTIPLE UNIT INSTALLATION

■ COMMON SPECIAL SPECIFICATION (TT2-80A series)

Item Specification
Frequency 1. Voltage/current transducer
► General frequency
(1) Frequency fixation (Fixed Hz ±10% Tolerance %)
variation
Frequency Tolerance Response time (±1%) Ripple (P-P)
40Hz-2kHz, ≦1 sec.
25Hz-2kHz ±0.5% 30Hz-39kHz, ≦1.5 sec.
25Hz-29kHz, ≦2 sec. ≦1%
2.1kHz-10kHz ≦1 sec.
±1%
20Hz-24Hz ≦2 sec.
(2) Frequency variation (tolerance % within the range)
Rated Hz Frequency Tolerance Response time (±1%) Ripple (P-P)
50/60Hz 35Hz-80Hz ±0.5% ≦1.5 sec.
≦1%
25Hz-200Hz ±1% ≦2 sec.
► Special frequency
2. Electric power transducer (only WTT-83 is manufacturable)
variation
(1) Frequency fixation (Fixed Hz ±10% Tolerance %)
Frequency Tolerance Response time (±1%) Ripple (P-P)
40Hz-2kHz, ≦1 sec.
30Hz-2kHz ±0.5%
30Hz-39kHz, ≦1.5 sec.
≦1%
2.1kHz-10kHz ≦1 sec.
±1%
20Hz-29Hz ≦2 sec.
Rated Hz (2) Frequency variation (tolerance % within the range)
50/60Hz Frequency Tolerance Response time (±1%) Ripple (P-P)
25Hz-100Hz ≦2 sec.
Consult us for the case 30Hz-90Hz ≦1.5 sec.
of CVVF. 40Hz-120Hz ±1% ≦1%
200Hz-600Hz ≦1 sec.
500Hz-1.5kHz
§ BOX TRANSDUCER §
COMMON STANDARD SPECIFICATION

Item Specification
Voltage/current/transducer
Response time (±1%) Frequency Ripple (P-P) Tolerance
≦0.1 sec. ≦5%
50/60Hz ±0.5%
≦0.2 sec. ≦3%
Electric power transducer (3 phase 3 wire type)
Response time (±1%) Frequency Ripple (P-P) Tolerance
≦1%
(Input sensitivity 120-80%)
Response time
≦2%
≦0.1 sec. 50/60Hz
(Input sensitivity 79-60%)
≦5%
±0.5%
(Input sensitivity 59-50%)
≦1%
(Input sensitivity 120-70%)
≦0.2 sec. 50/60Hz
≦2%
(Input sensitivity 69-50%)
IEC standard
Have a consultation with us for rating plate indication items, tolerance and line impulse and
conformity
so on.
(Pub. 688-1)
ANSI (SWC)
Please specify if any test by ANSI C37.90a-1974 is necessary.
test
Terminal cover Polycarbonate
Other Subject to consultation
§ BOX TRANSDUCER §
SMALL SIZED AC TRANSDUCER CONSTANT VOLTAGE/CURRENT TYPE 90 SERIES

. Small sized box transducer


that supports both DIN rail
mounting and wall mounting

■ FEATURES
●Heavy current oriented size reduction ●With a terminal cover as standard equipment.
●Withstand voltage AC2000V 50/60Hz for 1 min. ●Auxiliary supply DC100/110V (88-143V) is also
between input, output, auxiliary supply and earth. manufacturable.
●Impulse withstand voltage between electric circuit ●Supports both DIN rail mounting and wall
and earth 5kV 1.2/50µs positive/negative polarity 3 mounting.
times each.
●As a constant voltage/current output type, it is
possible to transmit an output directly to a distant
place.
■ COMMON SPECIFICATIONS

Item Specification
Tolerance % against output span
Influence of temperature 23±10℃ tolerance %
Influence of output load 1/2 of tolerance % based on the center value of rated output load
No display: 1/2 of tolerance % at 45-65Hz
Influence of frequency
Rated Hz display: 1/2 of tolerance % at rating ±5%
Characteristics In conformity with JIS C1111-1989
Response time Time it takes to fall within ±1% of the final steady-state value ≦1 sec.
Output ripple ≦1%P-P against output span
External adjustment of output ±5% adjustable
Confines output to about 1.5 times of rating and protects output side equipments when an
Output limiter circuit
excessive input is applied.
AC100/110V +10/-15% or AC200/220V +10/-15% (50/60Hz)
Auxiliary supply
DC24V±15% or DC48V or DC110V (88-143V)
Input 2 times of rated voltage for 10 sec., 1.2 times Continuity
Overvoltage
Auxiliary supply 1.5 times of rated voltage for 10 sec., 1.2 times Continuity
40 times of rated current 1 sec, 20 times 4 sec, 10 times 16 sec,
Overcurrent
1.2 times Continuity
≧50MΩ at DC500V between input terminal, output terminal,
Insulation resistance
auxiliary supply terminal and outer case (earth)
AC2,000V (50/60Hz) for 1 min. between input terminal, output terminal,
Withstand voltage
auxiliary supply terminal and outer case (earth)
Between electric circuit and outer case (earth) 5kV 1.2/50µs
Impulse withstand voltage
positive/negative polarity 3 times each
Terminal block: Fire-retardant ABS (V-O) Mixed glass fiber in by 15%
Material of case
Box: Fire-retardant ABS (V-O) Terminal cover: Polycarbonate

Terminal screw M4
Appearance color Black (Munsell 1.5)
Operating temperature/humidity
-10 - +55℃, 30 - 85%RH
range
Storage temperature range -40 - +70℃
§ BOX TRANSDUCER §
SMALL SIZED AC TRANSDUCER CONSTANT VOLTAGE/CURRENT TYPE 90 SERIES

■ PRODUCT RANGE

Rated DC
Measuring objective Rated AC input range Frequency
output range
AC current 0.1-10A 45Hz-65Hz 0.1-10V
AC voltage 50-300V 45Hz-65Hz 0.1-20mA
250-600W
(110V, 5A)
Single ±150-±600W
50-240V 1A, 5A 50/60Hz
phase 500-1, 200W
(220V, 5A)
Active ±300-±1, 200W
power 3 phase 3 500-1, 200W
(110V, 5A)
wire or 3 ±300-±1, 200W
50-240V 1A, 5A 50/60Hz
phase 4 1, 000-2, 400W ±0.1-±10V or
(220V, 5A)
wire ±600-±2, 400W ±0.1--5mA
3 phase 3 500-1, 200W +20mA
(110V, 5A)
Reactive wire or 3 ±300-±1, 200W
50-240V 1A, 5A 50/60Hz
power phase 4 1, 000-2, 400W
(220V, 5A)
wire ±600-±2, 400W
50 or 60Hz
V-V phase angle 50-240V - ±30°-±150° by
specification
45-65Hz (45Hz-1kHz 0.1-10V
Frequency 50-240V - -
by specification) 0.1-20mA

Have a consultation with us for those not included in the table above. (Shall be dealt with by TT2-80A series)
§ BOX TRANSDUCER §
SMALL SIZED AC TRANSDUCER 90 SERIES

ATT2-91A WTT2-92A-33
(120×40×130mm/0.5kg) (120×56×130mm/0.7kg)

■ SPECIFICATIONS

Continued on the next page


§ BOX TRANSDUCER §
SMALL SIZED AC TRANSDUCER 90 SERIES

●Standard of auxiliary supply: AC100/110V+10%-15%/AC200/220V+10%-15%/DC24V±15%/DC48V±15% or


DC100/110V (88-143V)
●Power and reactive power transducer can measure normally from input voltage 0V because the product has an
auxiliary supply. Power transducer can be used with SCR waveform.
●Output polarities of reactive power, phase angle and power factor transducer are LAG (+) and LEAD (-).
●Output of a V-V phase angle transducer shall be scaled out to minus side if input voltage of either BUS side or
START side is 0V. (at the time of auxiliary supply)
●Output of a V-I phase angle transducer or a power factor transducer becomes equivalent to power factor 1 at the
time of an input voltage 0V or an input current 0A. (at the time of auxiliary supply)
●Output of a frequency transducer becomes as follows at the time of input voltage 0V.
●In the case of voltage output 0-5V: approx. -0.6V, in the case of current output 4-20mA: approx. 2mA (at the time of
auxiliary supply).
§ BOX TRANSDUCER §
SMALL SIZED AC TRANSDUCER 90 SERIES

AT2-91 VT2-91
(120×40×130mm/0.3kg) (120×40×130mm/0.3kg)

AUXILIARY POWER not REQUIRED, LOAD FIXED TYPE

■ FEATURES
●Heavy current oriented size reduction
●Withstand voltage AC2000V 50/60Hz for 1 min. between input, output and earth.
●Protects output side equipments from an input side lightning surge with an electrostatic shield between primary and
secondary winding.
■ Features
●Load resistance fixed type
●Auxiliary supply not required type
●Terminal cover as a standard equipment
●Supports both DIN rail and wall mounting.

■ COMMON SPECIFICATION
See COMMON SPECIFICATION above
■ SPECIFICATION

*1 Please specify the voltage output with a load resistance 50kΩ or more.
Please specify the current output with a load resistance 5kΩ or more.
§ BOX TRANSDUCER §
SMALL SIZED SIGNAL TRANSDUCER TT2-91A

■ APPLICATION
This device amplifies various kinds of DC signals and converts them into
unified intersystem signals. Because input, output, power source and
earth are reciprocally insulated by a withstand voltage 2,000V, the
product offers full advantages in transmitting insulated signals between
power measuring systems, cutoff of noise, protecting control circuit from a
sneak current, and transmitting an output directly to a distant place.

■ FEATURES
●Withstand voltage AC2000V 50/60Hz for 1 min. between input, output,
auxiliary supply and earth. Isolator TT2-91A
●Impulse withstand voltage 5kV 1.2/50μs positive/negative polarity 3 (120×40×130mm/0.5kg)
times each between electric circuit and earth, auxiliary supply and
input/output.
●Supports both DIN rail and wall mounting.

■ SPECIFICATION

*1 Tolerance becomes ±0.5% in the case of input voltage less than 50mV, input current less than 500μA.
*2 For input 10μA, circuit voltage is 15V or less.
*3 Input voltage ranging from 10mV to 600V, input current ranging from 10μA to 100mA are manufacturable.
*4 Consult with us for voltage output up to 10V, current output up to 20mA.
*5 Rated voltage of auxiliary supply DC20―57V is DC24V or DC48V.
► Open current output: The output terminal can be used with the current output terminal open at all times.
Note that approx. 15V voltage will occur at the output terminal.

■ CONNECTION DIAGRAM

In the case of DC auxiliary


supply, connect the wire with S1
as + and S2 as -.
§ BOX TRANSDUCER §
SMALL SIZED SIGNAL TRANSDUCER TT2-91A

●Specifying special filter ●Response time


When a ripple equal to a single-phase AC full Please specify it if a product of a very fast response
rectification wave (50/60Hz) degree is included in time (60ms/99%) in control circuit is necessary.
input wave, it is necessary to specify a special filter
to convert it into a DC output. A 50/60Hz full
rectification wave filter is attached by specification.
Also, consult with us for special waveform such as
inverter.

■ PURCHASE SPECIFICATION
§ BOX TRANSDUCER §
SMALL SIZED AC TRANSDUCER CONSTANT VOLTAGE/CURRENT TYPE 90 SERIES

■ CONNECTION DIAGRAM (in the case of DC auxiliary supply, connect SI as +, S2 as -)

■ DIMENSIONS (mm) See the connection diagram above for terminal arrangement

* Use DIN 35mm standard


rail in the case of DIN rail
mounting (height 15mm).

■ PURCHASE SPECIFICATION
1. Type; 4. Auxiliary supply;
5. Quantity;
2. Input (rated voltage / current / frequency);
3. Output (load resistance);
§ BOX TRANSDUCER §
SMALL SIZED AC TRANSDUCER 90 SERIES SPECIFICATION CODE

1.AC CURRENT TRANSDUCER

2.AC VOLTAGE TRANSDUCER

3.RMS VALUE AC CURRENT TRANSDUCER

4.RMS VALUE TYPE AC VOLTAGE TRANSDUCER


§ BOX TRANSDUCER §
SMALL SIZED AC TRANSDUCER 90 SERIES SPECIFICATION CODE

5.1 POWER TRANSDUCER 1φ2W

5.2 POWER TRANSDUCER 1φ3W, 3φ3W, 3φ4W

6. REACTIVE POWER TRANSDUCER 3φ3W, 3φ4W


§ BOX TRANSDUCER §
SMALL SIZED AC TRANSDUCER 90 SERIES SPECIFICATION CODE

7. V-V PHASE ANGLE TRANSDUCER

8. V-I PHASE ANGLE TRANSDUCER

9. POWER FACTOR TRANSDUCER


§ BOX TRANSDUCER §
SMALL SIZED AC TRANSDUCER 90 SERIES SPECIFICATION CODE

10. FREQUENCY TRANSDUCER

11. LOAD FIXED TYPE AC CURRENT TRANSDUCER (power source-free type)

12. LOAD FIXED TYPE AC VOLTAGE TRANSDUCER (power source-free type)

You might also like