0% found this document useful (0 votes)
81 views

SCALEXIO IO Overview

The document describes the input and output functions of a system, listing various digital and analog inputs and outputs including failure insertion units, angular wavetable outputs, incremental encoder inputs, PWM outputs, and injection/ignition voltage and current inputs.

Uploaded by

manirnaidu
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
81 views

SCALEXIO IO Overview

The document describes the input and output functions of a system, listing various digital and analog inputs and outputs including failure insertion units, angular wavetable outputs, incremental encoder inputs, PWM outputs, and injection/ignition voltage and current inputs.

Uploaded by

manirnaidu
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

01/2021

www.dspace.com

I/O Function

I/O Overview In Out

Failure Insertion Unit integrated

Angular Wavetable Voltage Out

Digital Incremental Encoder Out


Angular Wavetable Digital Out
Digital Incremental Encoder In

Block Commutated PWM Out


Injection/Ignition Voltage In
Injection/Ignition Current In

Multi-Channel PWM Out

Crank/Cam Current Sink

Crank/Cam Voltage Out


Wavetable Current Sink

Waveform Current Sink


Wavetable Voltage Out

Waveform Voltage Out


Current Signal Capture

Voltage Signal Capture

Crank/Cam Digital Out


Wavetable Digital Out

Waveform Digital Out


Digital Pulse Capture
Triggered Current In
Number of channels

Potentiometer Out

Knock Signal Out


Digital Pulse Out

Wheelspeed Out

Lambda NCCR3)
Sine Encoder In

Resistance Out
Hall Encoder In

PWM/PFM Out

Lambda DCR3)
Extension1)

Extension1)
EnDat Master

Multi Bit Out


PWM/PFM In

Current Sink

Voltage Out
Multi Bit In

Resolver In

SSI Master
Voltage In
Current In

Trigger In

SENT Out
SENT In
DS6101 Multi-I/O Analog In 4 10   
Board
Analog In 5 1  
Digital In 3 12     
Flexible In 3 10         
Analog Out 6 8     
No

Analog Out 7 1    
Analog Out 8 3     
Analog Out 9 4          
Digital Out 3 14         
Resistance Out 2 6    

DS6121 Multi-I/O Analog In 16 6  


Board Resolver In 2 1 
No

Flexible In/Out 1 6     
Digital In/Out 9 4          
Digital Out 8 12     

DS6201 Digital
No

Digital In/Out 3 96    
I/O Board

DS6202 Digital
No

Digital In/Out 5 32               
I/O Board2)

DS6221 A/D Board Analog In 6 16  


No

Trigger In 1 8 
I/O Channels

DS6241 D/A Board Analog Out 10 20    


No

Trigger In 2 4 

DS2655 FPGA Base Board DS2655M1 I/O Module: 5 A/D channels, 5 D/A channels, 10 digital I/O channels
No

DS6601 FPGA Base Board DS2655M2 I/O Module: 32 digital I/O channels (RS232 or RS485 communication)
DS6602 FPGA Base Board DS6651 Multi-I/O Module: 6 A/D channels, 6 D/A channels, 16 digital I/O channels

DS2601 Signal
Yes

Flexible In 1 10              
Measurement Board

DS2621 Signal
Yes

Flexible Out 1 10                      
Generation Board

DS2642 FIU & Power Switch Board 10 Power Switch, Central FIU

DS2680 I/O Unit Analog In 1 20    


Analog In 2 2  
Digital In 1 30     
Flexible In 2 18            
Analog Out 1 15     
Yes

Analog Out 2 2    
Analog Out 3 7     
Analog Out 4 8          
Digital Out 1 28         
Resistance Out 1 12    
6 Power Switch, Central FIU

DS2690 Digital Digital In 2 10  


I/O Board
Yes

Digital Out 2 10  
Digital In/Out 1 10    
1)
Extension for using extended signal analysis. Additional channels are required. 2)
The number of function instances is limited for selected functions. 3)
Several channel types are required for this function.

Buses and Networks

Bus Overview
Automotive Ethernet (Physical Layer)
Standard Ethernet (Physical Layer)
Failure Insertion Unit integrated

SCALEXIO Aerospace Solutions


Number of channels

 SCALEXIO Interface Solution for ARINC 429


CAN/CAN FD

 SCALEXIO Interface Solution for ARINC 664 and AFDX®


SOME/IP
FlexRay

RS-232

RS-422

RS-485

(AFDX® is a registered trademark of AIRBUS)


UDP

TCP
LIN

 SCALEXIO Interface Solution for MIL-STD-1553


SCALEXIO Processing Ethernet Adapter 1 1    
No

Unit UART 5 1 
Additional SCALEXIO Solutions
DS6001 Processor Ethernet Adapter 1 1    
No

Board UART 6 1   SCALEXIO Fieldbus Solution for PROFIBUS and EtherCAT


 SCALEXIO Serial Interface Solution for Serial Peripheral Interface (SPI)
DS6301 CAN/LIN Board CAN 2 4 
No

LIN 2 4  and Inter-Integrated Circuit (I2C)


 SCALEXIO EMH Solution for Electric Drives Simulation
DS6311 FlexRay Board
No

FlexRay 2 4 
 SCALEXIO TWINsync Solution
DS6321 UART Board
No

UART 1 4   
 PSI5 Master/Slave Solution
DS6331-PE Ethernet
No

Ethernet Adapter 1 4    
Board

DS6333-CS Automotive
No

Ethernet Adapter 2 4     
Ethernet Board
SCALEXIO Bus Boards

DS6333-PE Automotive
No

Ethernet Adapter 2 4     
Ethernet Board

DS6334-PE Ethernet
No

Ethernet Adapter 1 4   
Board

DS6335-CS Ethernet
No

Ethernet Adapter 2 4    
Board

SCALEXIO Processing
No

Ethernet Adapter 1 1    
Unit

DS6336-CS Ethernet
No

Ethernet Adapter 1 2    
Board

DS6336-PE Ethernet
No

Ethernet Adapter 1 2    
Board
Yes No No No

DS6341 CAN Board CAN 2 4 

DS6342 CAN Board CAN 2 8 

DS6351 LIN Board LIN 2 8 

DS2671 Bus Board Bus 1 4      


DS2672 Bus Module CAN 1 2 
(Add-on for DS2680)
Yes

LIN 1 2 
FlexRay 1 2 