Gepdf
Gepdf
How to Order
Q-Line
—Thermal Magnetic Circuit Breakers
—Molded-Case Switches
The product number as shown in the following pages includes the
complete breaker or switch. TQD and TJD breakers are complete
with Cu/Al line and load lugs.
E 150 Line
—Thermal Magnetic Circuit Breakers
—Magnetic Circuit Breakers
—Molded Case Switches
The product numbers as shown in the following pages include the
complete breaker or switch. All devices listed come with Cu/Al line
and load lugs. If line lugs are not required on a breaker, eliminate
“WL” from product number; for molded case switches see page
6-3. Unless otherwise noted, all circuit breakers are UL listed in
File E–11592. Molded case switches are UL listed in File E–57546.
J 600 Line
—Thermal Magnetic Circuit Breakers
—Magnetic Circuit Breakers
—Molded Case Switches Q-Line Thermal Magnetic Circuit Breakers
These breakers are available with either noninterchangeable trip and Molded-Case Switches
(designated Type TJJ) or interchangeable trip (designated Type
TJK and THJK). Type TJJ product numbers include frame, trip,
Cu/Al line, and load lugs factory assembled. If line lugs are not
required on the breaker, eliminate “WL” from product number, and
Tri-Break™ Line
subtract price of line lugs from price of complete breaker.
—Integrally Fused Thermal Magnetic Circuit Breakers
TJK breakers are available in two frames, 400 ampere frame —Integrally Fused Magnetic Circuit Breakers
(125 to 400 amperes) and 600 ampere frame (250 to 600 —Integrally Fused Molded Case Switches
amperes). Trip units are not interchangeable between frames.
These breakers are available in three types. Type TB1 (15-100
“Complete Circuit Breaker” price includes frame, trip unit, Cu/Al amperes) product numbers include frame, trip, line and load
line, and load lugs. Unit will be shipped unassembled unless order lugs, and current limiters all factory assembled. TB6 (300 to 600
specifies “must be factory assembled.” If line lugs are not amperes) and TB8 (600 to 800 amperes) include frame, trip and
required, eliminate “WL” from product number and subtract price limiters, factory assembled, but do not include line or load lugs.
of line lugs from price of complete breaker. If line and load lugs are required, order separately. Unless other-
To order the frame, trip, and lugs separately, select the required wise noted, TB1, TB6, and TB8 breaker components are UL
components from table. Magnetic breakers must be ordered as listed in File E–42263. Fused molded case switches are UL
components. A complete breaker consists of frame, trip, and one listed in File E–57546.
line and one load lug per pole. Mag-Break Line
Price of ordering “Complete Circuit Breaker” vs. frame, trip, and —Magnetic only circuit breakers (motor circuit protectors)
line and load lugs separately is the same. These breakers are available only with noninterchangeable
Molded case switches can also be ordered as complete units adjustable magnetic trip, in frame Types E, F, J, K, and Tri-Break™.
(designated Type TJK---Y) or as separate components. They are All breakers are shipped factory assembled, complete with Cu/Al
UL listed only as complete units. To indicate required lugs, see line and load lugs.
page 6-3. All magnetic only circuit breakers and limiters are UL Component
Unless otherwise noted, all circuit breakers are UL listed in File Recognized in Files E–11592 and E–66390, respectively, unless
E–11592. Molded case switches are UL listed in File E–57546. otherwise noted.
Spectra™ RMS
—Circuit Breakers
Determine the required breaker frame, IC rating, and load
requirements. Select frame, trip unit (rating plug), and lug,
if required, product numbers from the tables on pages 6-45
to 6-53. For Spectra™ breakers with microEntelliGuard™ Trip
Units refer to pages 6-54 through 6-61. Select field-mounted
internal accessory product numbers, if required, on pages 6-67
and 6-68. Select field-mounted external accessory product
numbers, if required, on pages 6-98 through 6-109 and pages
6-62 to 6-66 for Spectra™ breakers with microEntelliGuard™
Trip Units. Order as separate items.
—Mag-Break Motor Circuit Protectors
Determine the required frame and ampere requirements.
Select frame, trip unit (rating plug), and lug, if required,
product numbers from the table on pages 6-91 through 6-92.
Select accessories as noted above for circuit breakers. The Spectra Circuit Breakers
same accessories are used with both circuit breakers and and Molded Case Switches
motor circuit protectors. Order as separate items.
—Molded Case Switches
Determine the required frame and ampere requirements. Molded Case Circuit Breaker and Switch Terminal
Select frame and lug, if required, product numbers from Configuration Code
the table on page 6-90. Rating plugs are not used. Select
Order standard Cu/Al lugs by using suffix codes presented. Order
accessories as noted above for circuit breakers. Internal
lugs separately if special lugs are required. For optional lugs, see
accessories do not require dummy trips. The same
pages 6-106 and 6-107.
accessories are used with both circuit breakers and molded
case switches. Order as separate items. Suffix
Breaker/Switch
Unless otherwise noted, all circuit breakers are UL listed in File Type Blank WL XL X2 LL
to 6-109.
—Spectra™ RMS Breakers—pages 6-66 to 6-67 and 6-97 to
6-109.
—Spectra™ RMS Breakers with microEntelliGuard™ Trip Units—
pages 6-62 to 6-68, and 6-97 to 6-109.
1Installation of accessories in molded case switches requires dummy trip; see page
6-44 for information. Dummy trip not required for Tri-Break™ or Q-Line molded
case switches.
Features
Spectra™ RMS Molded Case Circuit Breakers
SE150, SF250, SG600, and SK1200 circuit breaker frames have a
digital, solid-state, rms sensing trip system with field installable,
front-mounted rating plugs to establish or change the breaker
ampere rating. Adjustable instantaneous with tracking short-time
is standard on all frames including SE150. The trip system uses
digital sampling to determine the rms value of sinusoidal and
nonsinusoidal currents.
TEY and TEYF (UL File E-11592; Fixed Thermal Magnetic Trip Unit; CSA LR 57114)
1 277 125 65 14 14 — 10 — — — 1
15-70 1 277 — 65 65 — 25 — — — — — — 1 1 lb
15-70 1 277 — 65 65 — 35 — — — — — — 1 1 lb
E150 (UL File E-11592; Fixed Thermal Magnetic Trip Unit; CSA LR 57114)
1UL listed with poles in series for 500 Vdc ungrounded battery applications.
2UL listed as HACR (heating, air conditioning, and refrigeration).
315-50A UL listed as HID (high intensity discharge).
410 amp not UL listed, rated 5kA @ 120V, 240V and 480V
5UL listed/CSA Certified for 10kA @ 347 Vac (TED) and 18kA @ 347V (THED). Also rated 10kA @ 480V but not UL listed.
6480Y/277 Vac.
7UL listed 10kA, GE tested to 20kA.
8No longer available
9Not CSA listed
F225 (UL File E-11592; TFJ, Fixed Thermal Magnetic Trip Unit; TFK, THFK: Interchangeable Thermal Mag. Trip Unit; CSA LR 40350)
TFL8, 9 70-225 3 600 — — 100 100 — 65 25 — — — — 10 1/8 4 1/8 3 13/16 3 7/8 3 7/8 11/16 1 3/16 —
J600 (UL File E-11592; TJJ, Fixed Thermal Magnetic Trip Unit; TJK, THJK: Interchangeable Thermal Mag. Trip Unit; CSA LR 40350)
2 250 20 — — 18 lb/1
TJK6 250-600 600 — — 42 — 30 22 — 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16
1
3 500 20 20 — 20 lb/1
2 250 40 — — 16 lb/1
THJK4 125-400 600 — — 65 — 35 25 — 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16
3 500 40 201 — 17 1/2 lb/1
2 250 40 — 18 lb/1
THJK6 250-600 600 — — 65 — 35 25 — — 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16
3 500 40 201 20 lb/1
THJK4 D9 125-400 3 — 600 — — — — — — — 40 50 25 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16 17 1/2 lb/1
THJK6 D9 250-400 3 — 600 — — — — — — — 40 50 25 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16 20 lb/1
K1200 (UL File E-11592; Interchangeable Thermal Magnetic Trip Unit; CSA LR 40350)
2 250 20 — — 33 lb/1
TKM89 300-800 600 — — 42 — 30 22 — 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8
3 500 20 221 — 39 lb/1
2 38 lb/1
TKM129 600-1200 600 — — — 42 — 30 22 — — — — 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8
3 41 1/2 lb/1
2 250 40 — — 33 lb/1
THKM89 300-800 600 — — 65 — 35 25 — 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8
3 500 40 221 — 39 lb/1
2 38 lb/1
THKM129 600-1200 600 — — — 65 — 35 25 — — — — 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8
3 41 1/2 lb/1
1UL listed with poles in series for 500 Vdc ungrounded battery applications.
2UL listed as HACR (heating, air conditioning, and refrigeration).
315-50A UL listed as HID (high intensity discharge).
410 amp not UL listed, rated 5kA @ 120V, 240V and 480V
5UL listed/CSA Certified for 10kA @ 347 Vac (TED) and 18kA @ 347V (THED). Also rated 10kA @ 480V but not UL listed.
6480Y/277 Vac.
7UL listed 10kA, GE tested to 20kA.
8Not CSA listed
9Obsolete as of 12/13.
Legend
XXX = Variable in Product Number changes per application
IEC/JIS Ratings
Solid-State with Interchangeable Trip Unit (Rating Plug)
Japanese Industry Standard
IEC 947-2 Interruption Capacity — kA Interruption Capacity kA
Circuit 220-240 Vac 380-415 Vac 500 Vac 690 Vac Vac
Breaker Ampere No.
Type Rating Poles Icu I cs I cu I cs I cu I cs I cu I cs 220-240 380-415 500 690
SE150 Current Limiting, 15-32A
2 — — —
SED 18 9 10 5 — — 18 10 —
3 4 4 4
15-32
2 — — —
SEH 65 33 15 10 — — 65 15 —
3 6 6 6
2 — — — — — —
SEL 100 50 20 15 100 20
3 8 8 3 3 8 3
15-32
2 — — — — — —
SEP
3
200 100 20 20
10 10 5 5
200 20
10 5
SE
SE150 Current Limiting, 40-160A
2 — — —
SED 18 9 14 7 — — 18 14 —
3 14 7 14
40-160
2 — — —
SEH 65 33 35 17 — — 65 25 —
3 25 12 18
2 — — — — — —
SEL 100 50 65 33 100 65
3 40 20 5 5 25 5
40-160
2 — — — — — —
SEP 200 100 100 50 200 100
3 50 25 10 5 65 10
SF250 Current Limiting
2 — — —
SFH 70-250 65 33 35 17 — — 65 25 —
3 25 12 18
2 — — — — — —
SFL 100 50 65 33 100 65
3 40 20 14 7 25 14
70-250
2 — — — — — — SF
SFP 200 100 100 50 200 100
3 65 33 18 9 65 18
SG600 Current Limiting
SGH11 65 33 25 13 18 9 — — 65 25 18 —
SGL11 60-150 3 100 50 65 33 35 18 14 7 100 65 35 22
SGP11 200 100 100 50 50 25 18 9 200 100 65 35
2 — — — —
SGH4 65 33 25 13 — — 65 25
3 18 9 18 —
2 — — — — — —
SGL4 125-400 100 50 65 33 100 65
3 35 18 14 7 35 22
2 — — — — — —
SGP4 200 100 100 50 200 100
3 50 25 18 9 65 35
2 — — — —
SGH6 65 33 25 13 — — 65 25
3 18 9 18 —
2 — — — — — —
SGL6 250-600 100 50 65 33 100 65
3 35 18 14 7 35 22
2 — — — — — —
SGP6 200 100 100 50 200 100
3 50 25 18 9 65 35
SK1200 SG
2
SKH8 65 16 50 13 25 13 — — 65 50 25 —
3
2
SKL8 300-800 100 25 65 16 42 21 14 14 100 65 42 14
3
2
SKP8 140 35 85 25 50 25 18 18 140 85 50 18
3
2
SKH12 65 16 50 13 25 13 — — 65 50 25 —
3
2
SKL12 600-1250 100 25 65 21 42 16 14 14 100 65 42 14
3
2
SKP12 140 35 70 25 50 25 18 18 140 85 50 18
3
1 microEntelliGuard™, MicroVersaTrip™ Plus, and MicroVersaTrip™ PM Trip Units only.
SK
Tri-Break (UL File E-42263; Integrally Fused, Thermal Magnetic Trip Unit)
UL Listed Interrupting Ratings—
Maximum rms Symmetrical Amps (In Thousands) Approx.
Voltage
Circuit Ship
Rating Vac Vdc Dimensions (In.)
Breaker Ampere No. Wt./Std.
Type Rating Poles ac dc 120 120/240 240 277 480 600 125 250 H W D A B C E Pack
TB11,2 15-100 3 600 — — — 200 — 200 200 — — 10 5/16 4 1/8 3 5/8 2 21/32 6 9/32 11/16 23/32 8 lb/1
53 lb/1
TB61,3 300-600 3 600 — — — 200 — 200 200 — — 21 7/8 8 1/4 5 7/8 8 9/16 12 1/16 1 3/8 5/8
55 lb/1
53 lb/1
TB81,3 600-800 3 600 — — — 200 — 200 100 — — 21 7/8 8 1/4 5 7/8 8 9/16 12 1/16 1 3/8 5/8
55 lb/1
Mag-Break (UL Files E-11592, E-66390; Magnetic Trip Unit)4
10 lb/1
TFC9 225 3 600 — — — 25 — 22 18 — — 10 1/8 4 1/8 3 13/16 3 7/8 3 7/8 11/16 1 3/16
12 lb/1
31 lb/1
TBC49 225-400 3 600 — — — 100 — 100 100 — — 16 1/8 8 1/4 4 1/2 3 15/16 9 13/16 1 3/8 1 3/16
33 lb/1
16 lb/1
TJC 400-600 3 600 — — — 42 — 30 22 — — 10 1/8 8 1/4 3 13/16 3 13/16 3 13/16 1 3/8 1 3/16
17 1/2/1
53 lb/1
TBC6 600 3 600 — — — 100 — 100 100 — — 21 7/8 8 1/4 5 7/8 8 9/16 12 1/16 1 3/8 5/8
55 lb/1
38 lb/1
TKC 800-1200 3 600 — — — 42 — 30 22 — — 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8
41 1/2/1
53 lb/1
TBC8 800 3 600 — — — 100 — 100 100 — — 21 7/8 8 1/4 5 7/8 8 9/16 12 1/16 1 3/8 5/8
55 lb/1
TJ4V5,6,9 42 42 30 22
THJ4V5,6,9 150-600 3 600 — — 65 65 — 35 25 — — 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16 —
TJL4V5 100 100 65 30
TK4V5,9 800-1200 3 600 — — 42 42 — 30 22 — — 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8 —
TKL4V5,9 800-1200 3 600 — — 100 100 — 65 42 — — 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8 —
TJH1S-6S 60-600 3 600 — — 65 65 — 35 25 — — 16 1/8 8 1/4 3 13/16 3 15/16 9 13/16 1 3/8 1 3/16 —
TJL1S-6S 60-600 3 600 — — 100 100 — 65 30 — — 16 1/8 8 1/4 3 13/16 3 15/16 9 13/16 1 3/8 1 3/16 —
TKH8S9, 12S9 300-1200 3 600 — — 65 65 — 50 25 — — 21 7/8 8 1/4 5 1/2 8 9/16 12 11/16 1 3/8 5/8 —
TKL8S9, 12S9 300-1200 3 600 — — 100 100 — 65 42 — — 21 7/8 8 1/4 5 1/2 8 9/16 12 11/16 1 3/8 5/8 —
1 UL listed with internally mounted accessories at 100,000 amps IC. Contact GE Sales Office for availability of 200 kAIC ratings with internal accessories.
2 CSA LR 57114.
3 CSA LR 40350.
4 Per UL 489, interrupting capacities are not shown on product label.
5 With Power+ 4 trip unit.
6 Suitable for single-phase, use outer two poles.
7 No longer available.
8 Limited availability through Parts Super Center.
9 Obsolete as of 12/13.
The interruption ratings and voltages shown in the table are maximum ratings. A circuit breaker
of the type given in the left-hand column may be applied at the given circuit voltage in any
electrical distribution system where the available fault current at the load terminals of the
breaker does not exceed the value in the table. That circuit breaker type may also be applied at
intermediate values of circuit voltage provided the available fault current at the load terminals of
the breaker does not exceed the value in the table for the higher value of voltage.
FG 600
Ratings
FC 100 Amp Frame; Current Limiting (UL File No. E-11592)
Maximum UL Listed Interrupting Ratings - IEC Listed Interrupting Ratings, Approx.
Circuit Voltage rms Symmetrical Amperes (in Thousands) Icu, Amperes (in Thousands) Ship
Breaker Ampere No. Rating Vac Vdc Vac Vdc Dimensions in. (mm.) Wt./Std.
Type Rating Poles AC DC 240 480 600/347 250 (2p) 500 (3p) 220-240 400-415 500 250 (2p) 500 (3p) H W D Pack
FCS 15-100 2, 3 600 500 42 25 18 22 30 36 22 14 22 30 6.4 (162.6) 3.0 (76.2) 3.2 (81.3) 2.5 lb/1
FCV 15-100 2, 3 600 500 65 35 22 25 35 50 30 18 25 35 6.4 (162.6) 3.0 (76.2) 3.2 (81.3) 2.5 lb/1
FCN 15-100 2, 3 600 500 150 65 25 30 42 85 50 22 30 42 6.4 (162.6) 3.0 (76.2) 3.2 (81.3) 2.5 lb/1
FCH 15-100 2, 3 600 500 200 100 35 42 65 100 80 36 42 65 6.4 (162.6) 3.0 (76.2) 3.2 (81.3) 2.5 lb/1
FCL 15-100 2, 3 600 500 200 150 42 65 80 200 150 50 65 80 6.4 (162.6) 3.0 (76.2) 3.2 (81.3) 2.5 lb/1
FB 100 Amp Frame; Current Limiting (UL File No. E-11592)
Maximum UL Listed Interrupting Ratings - Approx.
Circuit Voltage rms Symmetrical Amperes (in Thousands) Ship
Breaker Ampere No. Rating Vac Dimensions in. (mm.) Wt./Std.
Type Rating Poles AC DC 240 277 347 480 600/347 H W D Pack
1 600/347 — 35 35 22 — — 6.45 (163.8) 1.36 (34.5) 3.28 (83.3) 1.1 lb/1
FBV 15-100 2 600/347 — 65 — — 35 22 6.45 (163.8) 2.74 (69.6) 3.28 (83.3) 2.6 lb/1
3 600/347 — 65 — — 35 22 6.45 (163.8) 4.11 (104.4) 3.28 (83.3) 3.3 lb/1
1 600/347 — 65 65 25 — — 6.45 (163.8) 1.36 (34.5) 3.28 (83.3) 1.1 lb/1
FBN 15-100 2 600/347 — 150 — — 65 25 6.45 (163.8) 2.74 (69.6) 3.28 (83.3) 2.6 lb/1
3 600/347 — 150 — — 65 25 6.45 (163.8) 4.11 (104.4) 3.28 (83.3) 3.3 lb/1
1 600/347 — 100 100 35 — — 6.45 (163.8) 1.36 (34.5) 3.28 (83.3) 1.1 lb/1
FBH 15-100 2 600/347 — 200 — — 100 35 6.45 (163.8) 2.74 (69.6) 3.28 (83.3) 2.6 lb/1
3 600/347 — 200 — — 100 35 6.45 (163.8) 4.11 (104.4) 3.28 (83.3) 3.3 lb/1
1 600/347 — 100 100 42 — — 6.45 (163.8) 1.36 (34.5) 3.28 (83.3) 1.1 lb/1
FBL 15-100 2 600/347 — 200 — — 150 42 6.45 (163.8) 2.74 (69.6) 3.28 (83.3) 2.6 lb/1
3 600/347 — 200 — — 150 42 6.45 (163.8) 4.11 (104.4) 3.28 (83.3) 3.3 lb/1
FE 250 Amp Frame; Current Limiting (UL File No. E-11592)
Maximum UL Listed Interrupting Ratings - Approx.
Circuit Voltage rms Symmetrical Amperes (in Thousands) Ship
Breaker Ampere No. Rating Vac Dimensions in. (mm.) Wt./Std.
Type Rating Poles AC DC 240 480 600 H W D Pack
FEN 250 2 480 - 150 65 - 6.70 (170.1) 4.11 (104.4) 3.52 (89.5) 4.5 lb/1
FEN 250 3 480 - 150 65 - 6.70 (170.1) 4.11 (104.4) 3.52 (89.5) 4.5 lb/1
FEH 250 2 480 - 200 100 - 6.70 (170.1) 4.11 (104.4) 3.52 (89.5) 4.5 lb/1
FEH 250 3 480 - 200 100 - 6.70 (170.1) 4.11 (104.4) 3.52 (89.5) 4.5 lb/1
FG 600 Amp Frame; Current Limiting (UL File No. E-11592)
Maximum UL Listed Interrupting Ratings - EN 60947-2 Interrupting Ratings, Approx.
Circuit Voltage rms Symmetrical Amperes (in Thousands) Icu, Amperes (in Thousands) Ship
Breaker Ampere No. Rating Vac Vac Dimensions in. (mm.) Wt./Std.
Type Rating Poles AC DC 240 480 600 240 400-415 690 H W D Pack
2 600 — 150 65 25 — — — 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
FGN 250-600
3 600 — 150 65 25 85 50 10 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
2 600 — 200 100 35 — — — 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
FGH 250-600
3 600 — 200 100 35 100 80 22 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
2 600 — 200 150 42 — — — 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
FGL 250-600
3 600 — 200 150 42 200 150 40 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
2 600 — 200 200 65 — — — 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
FGP 250-600
3 600 — 200 200 65 — — — 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
THQL 120/240 Vac, Internal Common Trip with Factory Installed Shunt
# of Ampere 240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 10kA THQL2115ST1
2 20 14-8 Cu/12-8 Al 10kA THQL2120ST1
2 30 14-8 Cu/12-8 Al 10kA THQL2130ST1
2 35 8-3 Cu/8-3 Al 10kA THQL2135ST1
2 40 8-3 Cu/8-3 Al 10kA THQL2140ST1
2 45 8-3 Cu/8-3 Al 10kA THQL2145ST1
2 50 8-3 Cu/8-3 Al 10kA THQL2150ST1
2 60 8-3 Cu/8-3 Al 10kA THQL2160ST1
2 70 6-1/0 Cu/4-1/0 Al 10kA THQL2170ST1
2 80 6-1/0 Cu/4-1/0 Al 10kA THQL2180ST1
2 90 6-1/0 Cu/4-1/0 Al 10kA THQL2190ST1
2 100 6-1/0 Cu/4-1/0 Al 10kA THQL21100ST1
3 20 14-8 Cu/12-8 Al 10kA THQL32020ST1
3 30 14-8 Cu/12-8 Al 10kA THQL32030ST1 THQL32020ST1
3 40 8-3 Cu/8-3 Al 10kA THQL32040ST1
3 50 8-3 Cu/8-3 Al 10kA THQL32050ST1
3 60 8-3 Cu/8-3 Al 10kA THQL32060ST1
3 70 6-1/0 Cu/4-1/0 Al 10kA THQL32070ST1
3 80 6-1/0 Cu/4-1/0 Al 10kA THQL32080ST1
3 90 6-1/0 Cu/4-1/0 Al 10kA THQL32090ST1
3 100 6-1/0 Cu/4-1/0 Al 10kA THQL32100ST1
THQL and THHQL 120 Vac, Equipment Protection Ground Fault Circuit
Breakers Internal Common Trip
# of Ampere 120 Vac THQL1120GF
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 10kA THQL1115GFEP
1 20 14-8 Cu/12-8 Al 10kA THQL1120GFEP
1 30 14-8 Cu/12-8 Al 10kA THQL1130GFEP
THQL2120HID
THQL and THHQL 120/240 Vac, High Intensity Discharge Lighting Loads
# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 10kA THQL1115HID2
1 20 14-8 Cu/12-8 Al 10kA THQL1120HID2
1 25 14-8 Cu/12-8 Al 10kA THQL1125HID
1 30 14-8 Cu/12-8 Al 10kA THQL1130HID
1 15 14-8 Cu/12-8 Al 22kA THHQL1115HID2
1 20 14-8 Cu/12-8 Al 22kA THHQL1120HID2
1 25 14-8 Cu/12-8 Al 22kA THHQL1125HID
1 30 14-8 Cu/12-8 Al 22kA THHQL1130HID
UL listed as HID.
THQL and THHQL 120/240 Vac, Internal Common Trip For High Intensity
Discharge Lighting Loads
# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 10kA THQL2115HID
2 20 14-8 Cu/12-8 Al 10kA THQL2120HID
2 25 14-8 Cu/12-8 Al 10kA THQL2125HID
2 30 14-8 Cu/12-8 Al 10kA THQL2130HID
2 15 14-8 Cu/12-8 Al 22kA THHQL2115HID
2 20 14-8 Cu/12-8 Al 22kA THHQL2120HID
2 25 14-8 Cu/12-8 Al 22kA THHQL2125HID
2 30 14-8 Cu/12-8 Al 22kA THHQL2130HID
UL listed as HID.
1Solid or stranded for 14-10 AWG.
2UL listed as SWD (switching duty). Suitable for 120 Vac fluorescent lighting loads.
THQL1120HM
THQL 120 Vac, For Factory Installed Shunt Trip2,3 Internal Common Trip
# of Ampere 120 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
3 20 14-8 Cu/12-8 Al 10kA THQL32020ST1
THQB, THHQB 120/240 Vac, Ground Fault Circuit Interrupters, Self Testing THQB1115GF
# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8Cu/12-8 Al 10kA THQB1115GF3
1 20 14-8Cu/12-8 Al 10kA THQB1120GF3
1 30 14-8Cu/12-8 Al 10kA THQB1130GF3
1 15 14-8Cu/12-8 Al 22kA THHQB1115GF3
1 20 14-8Cu/12-8 Al 22kA THHQB1120GF3
1 30 14-8Cu/12-8 Al 22kA THHQB1130GF3
2 15 14-8Cu/12-8 Al 10kA THQB2115GF3
2 20 14-8Cu/12-8 Al 10kA THQB2120GF3
2 30 14-8Cu/12-8 Al 10kA THQB2130GF3
THQB 120 Vac, Ground Fault Circuit Circuit Interrupters (30 ma)
# of Ampere 120 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 10kA THQB1115GFEP
1 20 14-8 Cu/12-8 Al 10kA THQB1120GFEP
1 30 14-8 Cu/12-8 Al 10kA THQB1130GFEP
THQB 120/240 or 208Y/120 Vac, Ground Fault Circuit Interrupters (30 ma)
Internal Common Trip
# of Ampere 120/240 or 208Y/120 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 10kA THQB2115GFEP
2 20 14-8 Cu/12-8 Al 10kA THQB2120GFEP
2 30 14-8 Cu/12-8 Al 10kA THQB2130GFEP
2 40 14-8 Cu/12-8 Al 10kA THQB2140GFEP
1Solid or stranded for 14-10 AWG.
2Meets ‘Combination Type’ AFCI requirement per NEC2005 / 2008 210.12 (B).
THHQB 120/240 Vac, Internal Common Trip, High Intensity Discharge Lighting Loads1
# of Ampere 120/240 Vac
Poles Rating Wire Range2 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 22kA THHQB2115HID
2 20 14-8 Cu/12-8 Al 22kA THHQB2120HID
2 25 14-8 Cu/12-8 Al 22kA THHQB2125HID
2 30 14-8 Cu/12-8 Al 22kA THHQB2130HID
THQB 120 Vac with Factory Installed 120 Vac Shunt Trip4,5
# of Ampere 120 Vac
Poles Rating Wire Range2 Interrupting Rating Product Number
1 20 14-8 Cu/12-8 Al 10kA THQB1120ST1
THQB 120 Vac, Internal Common Trip with Factory Installed 120 Vac Shunt Trip4,5
# of Ampere 120 Vac
Poles Rating Wire Range2 Interrupting Rating Product Number
2 20 14-8 Cu/12-8 Al 10kA THQB2120ST1
2 30 14-8 Cu/12-8 Al 10kA THQB2130ST1
2 100 6-1/0 Cu/4-1/0 Al 10kA THQB21100ST1
3 20 14-8 Cu/12-8 Al 10kA THQB32020ST1
3 30 14-8 Cu/12-8 Al 10kA THQB32030ST1
3 35 8-3 Cu/8-3 Al 10kA THQB32035ST1
3 40 8-3 Cu/8-3 Al 10kA THQB32040ST1
3 50 8-3 Cu/8-3 Al 10kA THQB32050ST1
3 60 8-3 Cu/8-3 Al 10kA THQB32060ST1
3 70 6-1/0 Cu/4-1/0 Al 10kA THQB32070ST1
3 80 6-1/0 Cu/4-1/0 Al 10kA THQB32080ST1
3 90 6-1/0 Cu/4-1/0 Al 10kA THQB32090ST1
3 100 6-1/0 Cu/4-1/0 Al 10kA THQB32100ST1
THQB 120 Vac with Switching Neutral Single Thermal Magnetic Pole;
Single Nonautomatic Pole
# of Ampere 120 Vac
Poles Rating Wire Range2 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 10kA THQB21WY15
2 20 14-8 Cu/12-8 Al 10kA THQB21WY20
2 25 14-8 Cu/12-8 Al 10kA THQB21WY25
2 30 14-8 Cu/12-8 Al 10kA THQB21WY30
THQB 120 Vac with Switching Neutral Two Thermal Magnetic Pole;
Single Nonautomatic Pole
# of Ampere 120 Vac
Poles Rating Wire Range2 Interrupting Rating Product Number
3 15 14-8 Cu/12-8 Al 10kA THQB31WY15
3 20 14-8 Cu/12-8 Al 10kA THQB31WY20
3 25 14-8 Cu/12-8 Al 10kA THQB31WY25
3 30 14-8 Cu/12-8 Al 10kA THQB31WY30
UL listed HACR (heating, air conditioning and refrigeration). Refer to Q-Line accessories listed on pages 6-30 to 6-31.
THQC1120GF
TXQC 120/240 Vac
# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 65kA TXQC1115WL
1 20 14-8 Cu/12-8 Al 65kA TXQC1120WL
1 25 14-8 Cu/12-8 Al 65kA TXQC1125WL
1 30 14-8 Cu/12-8 Al 65kA TXQC1130WL
Product Features
Multi-terminal Configuration Breakers
—35 mm DIN rail mounting
—Optional front/rear panel mounting kits–THQCFMK, page 6-30.
—Optional load end terminal for up to (4) 0.25-inch quick connnects.
Contact local GE sales office for ring terminal configurations–not DIN rail compatible.
TQD 240 Vac, Internal Common Trip with Factory Installed 120 Vac Shunt Trip3
# of Ampere 240 Vac
Poles Rating Interrupting Rating Product Number 1,2
3 125 10kA TQD32125ST1
3 150 10kA TQD32150ST1
3 175 10kA TQD32175ST1
3 200 10kA TQD32200ST1
3 225 10kA TQD32225ST1
Cable In-Cable Out (Lug-Lug) TQC 120/240 Vac, Internal Common Trip
# of Ampere 120/240 Vac
Poles Rating Wire Range1 Short Circuit Withstand Rating Product Number
2 60 8-3 Cu/8-3 Al 10kA TQC21Y60
2 100 6-1/0 Cu/4-1/0 Al 10kA TQC21Y100
Cable In-Cable Out (Lug-Lug) TQC 240 Vac, Internal Common Trip
# of Ampere 240 Vac
Poles Rating Wire Range1 Short Circuit Withstand Rating Product Number
2 60 8-3 Cu/8-3 Al 10kA TQC22Y60
2 100 6-1/0 Cu/4-1/0 Al 10kA TQC22Y100
3 60 8-3 Cu/8-3 Al 10kA TQB32Y60
3 100 6-1/0 Cu/4-1/0 Al 10kA TQB32Y100
Cable In-Cable Out (Lug-Lug) TQD, TJD 240 Vac, Internal Common Trip
# of Ampere 240 Vac
Poles Rating Short Circuit Withstand Rating Product Number 4
2 225 14kA TQD22Y225
3 225 14kA TQD32Y2252
2 400 22kA TJD422Y400
3 400 22kA TJD432Y4003
1Solid or stranded for 14-10 AWG.
2TQD32YT225 with dummy trip used for accessorized applications.
3TJD uses same accessories as J600 line.
4Refer to table on page 6-106 for lug and wire range data. Line and load lugs included in basic switch product number.
TQHT1
TEY and TEYF breakers are one-inch wide per pole, compact, bolt-on circuit breakers
for use on grounded 480Y/277 Vac systems. Short circuit ratings at that voltage for TEY
and TEYF are 14 and 18kA, respectively. TEYF also offers higher selectivity ratings with
upstream devices (See DET-537 for details). The bolt-on mounting base (TEY3B) shown
on page 6-105 makes TEY and TEYF suitable for various lug-lug applications.
TEY/TEYF
14kA @ 277, 480/277 Vac; 18kA @ 277, 480/277, 180/277 Vac
Ampere
Rating Wire Range1 Product Number Product Number
Type TEY3,4 Type TEYF3,4
Single Pole - Includes Integral Cu/Al Load Lugs 14kA @ 277 Vac 18kA @ 277 Vac
15 14-10 Cu/14-10 Al TEY1152 TEYF1152
20 14-10 Cu/14-10 Al TEY1202 TEYF1202
25 14-10 Cu/14-10 Al TEY125 TEYF125
30 14-10 Cu/14-10 Al TEY130 TEYF130
35 10-4 Cu/10-4 Al TEY135 TEYF135 1- 2- and 3-pole TEY/TEYF breakers
40 10-4 Cu/10-4 Al TEY140 TEYF140
45 10-4 Cu/10-4 Al TEY145 TEYF145
50 10-4 Cu/10-4 Al TEY150 TEYF150
60 10-4 Cu/10-4 Al TEY160 TEYF160
70 4-1/0 Cu/4-1/0 Al TEY170
80 4-1/0 Cu/4-1/0 Al TEY180
90 4-1/0 Cu/4-1/0 Al TEY190
100 4-1/0 Cu/4-1/0 Al TEY1100
Type TEY3,4 Type TEYF3,4
Two-Pole - Includes Integral Cu/Al Load Lugs 14kA @ 480 / 277 Vac 18kA @ 480 / 277 Vac
15 14-10 Cu/14-10 Al TEY215 TEYF215
20 14-10 Cu/14-10 Al TEY220 TEYF220
25 14-10 Cu/14-10 Al TEY225 TEYF225
30 14-10 Cu/14-10 Al TEY230 TEYF230
35 10-4 Cu/10-4 Al TEY235 TEYF235
40 10-4 Cu/10-4 Al TEY240 TEYF240
45 10-4 Cu/10-4 Al TEY245 TEYF245
50 10-4 Cu/10-4 Al TEY250 TEYF250
60 10-4 Cu/10-4 Al TEY260 TEYF260
70 4-1/0 Cu/4-1/0 Al TEY270 TEYF270
80 4-1/0 Cu/4-1/0 Al TEY280 TEYF280
90 4-1/0 Cu/4-1/0 Al TEY290 TEYF290
100 4-1/0 Cu/4-1/0 Al TEY2100 TEYF2100
110 4-2/0 TEYF2110B
125 4-2/0 TEYF2125B
Type TEY3,4 Type TEYF3,4
Three-Pole - Includes Integral Cu/Al Load Lugs 14kA @ 480 / 277 Vac 18kA @ 480 / 277 Vac
15 14-10 Cu/14-10 Al TEY315 TEYF315
20 14-10 Cu/14-10 Al TEY320 TEYF320
25 14-10 Cu/14-10 Al TEY325 TEYF325
30 14-10 Cu/14-10 Al TEY330 TEYF330
35 10-4 Cu/10-4 Al TEY335 TEYF335
40 10-4 Cu/10-4 Al TEY340 TEYF340
45 10-4 Cu/10-4 Al TEY345 TEYF345
50 10-4 Cu/10-4 Al TEY350 TEYF350
60 10-4 Cu/10-4 Al TEY360 TEYF360
70 4-1/0 Cu/4-1/0 Al TEY370 TEYF370
80 4-1/0 Cu/4-1/0 Al TEY380 TEYF380
90 4-1/0 Cu/4-1/0 Al TEY390 TEYF390
100 4-1/0 Cu/4-1/0 Al TEY3100 TEYF3100
110 4-2/0 TEYF3110B
125 4-2/0 TEYF3125B
1Solid or stranded for 14-10 AWG.
2Single-pole, 15 and 20 ampere breakers are also UL listed as switching duty breakers, suitable for switching
120, 240, or 277 Vac.
3UL listed HACR (Heating, Air Conditioning, Refrigeration).
4UL listed for HID (high intensity discharge), all 50A or less.
Internal Accessories for TEY/TEYF (2- and 3-pole breaker only) Factory Installed Only
Auxiliary Switch, Single-Pole Add suffix to Breaker
(5A at 120, 240, 277 Vac, 1/4 hp at 120, 240 Vdc) Product Number
“A” switch (normally open) AS1A5
“B” switch (normally closed) AS1B5
“AB” switch (both) ASAB5
Shunt Trip 120-277 Vac control voltage ST125
5Limited to one accessory per breaker.
The TEY family of circuit breakers (TEY, TEYF, TEYD, TEYH, and TEYL) are one-inch wide per
pole, compact, bolt-on circuit breakers for use on grounded 480Y/277 Vac systems, and
are typically installed within Lighting Panelboards, including GE A-Series. Short circuit
ratings at 480/277 Vac are shown in the tables that follow. Ratings at other voltages are
shown in the Quick Reference Guide at the beginning of this section. Bolt-On mounting
bases TEY3B (page 6-105) and TEY3B125 (page 6-34) make these frames suitable for
unit mount / lug-lug connected applications. Handle tie kits, suitable for use with multiple
single pole breakers used on shared neutral circuits (page 6-34) are available for
TEYD/H/L circuit breakers.
TEYD/TEYH/TEYL
25kA 480/277; 35kA 480/277; 65kA 480/277
Ampere Wire
Rating Range1 Product No. Product No. Product No.
Single Pole Type TEYD Type TEYH Type TEYL 1- 2- and 3-pole
Includes Load Lugs 25kA @ 480 / 277 Vac 35kA @ 480 / 277 Vac 65kA @ 480 / 277 Vac TEYD/TEYH/TEYL breakers
15 #14-#10 TEYD1015B TEYH1015B TEYL1015B
20 #14-#10 TEYD1020B TEYH1020B TEYL1020B
25 #10-#4 TEYD1025B TEYH1025B TEYL1025B
30 #10-#4 TEYD1030B TEYH1030B TEYL1030B
35 #10-#4 TEYD1035B TEYH1035B TEYL1035B
40 #10-#4 TEYD1040B TEYH1040B TEYL1040B
45 #10-#4 TEYD1045B TEYH1045B TEYL1045B
50 #10-#4 TEYD1050B TEYH1050B TEYL1050B
60 #10-#4 TEYD1060B TEYH1060B TEYL1060B
70 #4-2/0 TEYD1070B TEYH1070B TEYL1070B
Two-Pole Type TEYD Type TEYH Type TEYL
Includes Load Lugs 25kA @ 480 / 277 Vac 35kA @ 480 / 277 Vac 65kA @ 480 / 277 Vac
15 #14-10 TEYD2015B TEYH2015B TEYL2015B
20 #14-10 TEYD2020B TEYH2020B TEYL2020B
25 #10-#4 TEYD2025B TEYH2025B TEYL2025B
30 #10-#4 TEYD2030B TEYH2030B TEYL2030B
35 #10-#4 TEYD2035B TEYH2035B TEYL2035B
40 #10-#4 TEYD2040B TEYH2040B TEYL2040B
45 #10-#4 TEYD2045B TEYH2045B TEYL2045B
50 #10-#4 TEYD2050B TEYH2050B TEYL2050B
60 #10-#4 TEYD2060B TEYH2060B TEYL2060B
70 #4-2/0 TEYD2070B TEYH2070B TEYL2070B
80 #4-2/0 TEYD2080B TEYH2080B TEYL2080B
90 #4-2/0 TEYD2090B TEYH2090B TEYL2090B
100 #4-2/0 TEYD2100B TEYH2100B TEYL2100B
110 #4-2/0 TEYD2110B TEYH2110B TEYL2110B
125 #4-2/0 TEYD2125B TEYH2125B TEYL2125B
Three-Pole Type TEYD Type TEYH Type TEYL
Includes Load Lugs 25kA @ 480 / 277 Vac 35kA @ 480 / 277 Vac 65kA @ 480 / 277 Vac
15 #14-#10 TEYD3015B TEYH3015B TEYL3015B
20 #14-#10 TEYD3020B TEYH3020B TEYL3020B
25 #10-#4 TEYD3025B TEYH3025B TEYL3025B
30 #10-#4 TEYD3030B TEYH3030B TEYL3030B
35 #10-#4 TEYD3035B TEYH3035B TEYL3035B
40 #10-#4 TEYD3040B TEYH3040B TEYL3040B
45 #10-#4 TEYD3045B TEYH3045B TEYL3045B
50 #10-#4 TEYD3050B TEYH3050B TEYL3050B
60 #10-#4 TEYD3060B TEYH3060B TEYL3060B
70 #4-2/0 TEYD3070B TEYH3070B TEYL3070B
80 #4-2/0 TEYD3080B TEYH3080B TEYL3080B
90 #4-2/0 TEYD3090B TEYH3090B TEYL3090B
100 #4-2/0 TEYD3100B TEYH3100B TEYL3100B
110 #4-2/0 TEYD3110B TEYH3110B TEYL3110B
125 #4-2/0 TEYD3125B TEYH3125B TEYL3125B
1Solid or stranded for 14-10 AWG.
2Single-pole, 15 and 20 ampere breakers are also UL listed as switching duty breakers, suitable for switching
120, 240, or 277 Vac.
3UL listed HACR (Heating, Air Conditioning, Refrigeration).
4UL listed for HID (high intensity discharge), all 50A or less.
TEB 1 1 1 015 WL
Single Pole — Includes Cu/Al load lugs only. If line lugs are required, add suffix “WL” to Product Number.
Type TEB Type TED Type THED
120 Vac 125 Vdc 277 Vac 125 Vdc 347 Vac1 277 Vac 347 Vac1
Ampere
Rating Product Number Product Number Product Number Product Number Product Number
10 TEB1110102,4 TED1130102,4
15 TEB1110153,4 TED1130153,4 TED1140153,4 THED1130154 THED1140153,4
20 TEB1110203,4 TED1130203,4 TED1140203,4 THED1130204 THED1140203,4
25 TEB1110254 TED1130254 TED1140254 THED1130254 THED1140254
30 TEB1110304 TED1130304 TED1140304 THED1130304 THED1140304
35 TEB1110354 TED1130354 — — —
40 TEB1110404 TED1130404 — — —
45 TEB1110454 TED1130454 — — —
50 TEB1110504 TED1130504 — — —
60 TEB111060 TED113060 — — —
70 TEB111070 TED113070 — — —
80 TEB111080 TED113080 — — —
90 TEB111090 TED113090 — — —
100 TEB111100 TED113100 — — —
Two Pole — Includes Cu/Al line and load lugs. For optional lugs, see page 6-106 and 6-108.
Type TEB Type TED Type THED, Hi-Break 5
240 Vac, 250 Vdc 480 Vac, 250 Vdc 480 Vac, 250 Vdc
Ampere
Rating Product Number Product Number Product Number
10 TEB122010WL2,4 TED124010WL2,4 —
15 TEB122015WL4 TED124015WL4 THED124015WL4
20 TEB122020WL4 TED124020WL4 THED124020WL4
25 TEB122025WL4 TED124025WL4 THED124025WL4
30 TEB122030WL4 TED124030WL4 THED124030WL4
35 TEB122035WL4 TED124035WL4 THED124035WL4
40 TEB122040WL4 TED124040WL4 THED124040WL4
45 TEB122045WL4 TED124045WL4 THED124045WL4
50 TEB122050WL4 TED124050WL4 THED124050WL4
60 TEB122060WL TED124060WL THED124060WL
70 TEB122070WL TED124070WL THED124070WL
80 TEB122080WL TED124080WL THED124080WL
90 TEB122090WL TED124090WL THED124090WL
100 TEB122100WL TED124100WL THED124100WL
110 — TED124110WL —
125 — TED124125WL —
150 — TED124150WL —
1Suitable for 10 kAIC at 480 Vac, but not labeled or UL listed.
2Not UL listed, rated 5kA @ 120V, 240V and 480V.
3Single-pole, 15-and 20-ampere breakers are also UL listed as switching duty breakers, suitable for switching 120 Vac (TEB), 277, 347 Vac (TED, THED) fluorescent lighting loads.
4UL listed for HID (high intensity discharge).
5Two-pole breaker is furnished in three-pole case.
Notes: All TEB, TED, THED breakers UL listed as HACR type except 10 ampere.
All TEB, TED, THED breakers suitable for reverse feed.
60/75°C rating through 100 amperes, 75°C rating above 100 amperes.
Three Pole — Includes Cu/Al line and load lugs. For optional lugs, see page 6-106 and 6-108.
Type TEB Type TED Type THED, Hi-Break
240 Vac 480 Vac 600 Vac 600 Vac
Ampere
Rating Product Number Product Number Product Number Product Number
10 TEB132010WL1,3 TED134010WL1,3 — —
15 TEB132015WL3 TED134015WL3 — —
20 TEB132020WL3 TED134020WL3 TED136020WL3 THED136020WL3
25 TEB132025WL3 TED134025WL3 TED136025WL3 THED136025WL3
30 TEB132030WL3 TED134030WL3 TED136030WL3 THED136030WL3
35 TEB132035WL3 TED134035WL3 TED136035WL3 THED136035WL3
40 TEB132040WL3 TED134040WL3 TED136040WL3 THED136040WL3
45 TEB132045WL3 TED134045WL3 TED136045WL3 THED136045WL3
50 TEB132050WL3 TED134050WL3 TED136050WL3 THED136050WL3
60 TEB132060WL TED134060WL TED136060WL —
70 TEB132070WL TED134070WL TED136070WL THED136070WL
80 TEB132080WL TED134080WL TED136080WL —
90 TEB132090WL TED134090WL TED136090WL THED136090WL
100 TEB132100WL TED134100WL TED136100WL THED136100WL
110 — TED134110WL TED136110WL THED136110WL
125 — TED134125WL TED136125WL THED136125WL
150 — TED134150WL TED136150WL THED136150WL
100NA — TED134YT1002 TED136YT1002 —
150NA — TED134YT1502 TED136YT1502 —
1Not UL listed, rated 5kA @ 120V, 240V and 480V.
2Includes factory-installed dummy trip.
3UL listed for HID (high intensity discharge).
Notes: All TEB, TED, THED breakers UL listed as HACR type except 10 ampere.
All TEB, TED, THED breakers suitable for reverse feed.
60/75°C rating through 100 amperes, 75°C rating above 100 amperes.
Type TJJ Noninterchangeable Trip, includes Cu/Al Line and Load Lugs, suitable for reverse feed
Frame
2-Pole, 400 Ampere Frame 3-Pole, 400 Ampere Frame Terminal Lugs for Front
Adjustable Instantaneous 600 Vac, 250 Vdc 600 Vac Connection (Cu/Al)
Trip Ampere Range
Ampere Product Product Copper/ Wire
Rating Low High Number Number Aluminum Lugs Size
125 375 1250 TJJ426125WL TJJ436125WL
150 450 1500 TJJ426150WL TJJ436150WL
175 525 1750 TJJ426175WL TJJ436175WL
200 600 2000 TJJ426200WL TJJ436200WL TCAL433
225 675 2250 TJJ426225WL TJJ436225WL Included in (1) 6-600 or
250 750 2500 TJJ426250WL TJJ436250WL price of (2) 2/0-250 Cu/Al
300 900 3000 TJJ426300WL TJJ436300WL breaker
350 1050 3500 TJJ426350WL TJJ436350WL
400 1200 4000 TJJ426400WL TJJ436400WL
Types TJK, THJK — Interchangeable Trip, includes Cu/Al Line and Load Lugs, not suitable for reverse feed
Complete Circuit Breaker Terminal Lugs for Front
Includes Line and Load Lugs Connection (Cu/Al)1
Adjustable Instantaneous
Trip Ampere Frame Only Trip Unit Only. Use Product Number
Ampere Range Standard Hi-Break Product with Standard and (Order 2
Rating Low High Product Number Product Number Number Hi-Break Frames per pole) Wire Size
400A Frame—Two-Pole
125 375 1250 TJK426125WL THJK426125WL TJK426T125
150 450 1500 TJK426150WL THJK426150WL TJK426F000 TJK426T150
175 525 1750 TJK426175WL THJK426175WL Standard TJK426T175
200 600 2000 TJK426200WL THJK426200WL Frame TJK426T200
225 675 2250 TJK426225WL THJK426225WL TJK426T225
250 750 2500 TJK426250WL THJK426250WL TJK426T250 TCAL433 (1) 6-600
300 900 3000 TJK426300WL THJK426300WL THJK426F000 TJK426T300 or
350 1050 3500 TJK426350WL THJK426350WL Hi-Break TJK426T350 (2) 2/0-250 Cu/Al
400 1200 4000 TJK426400WL THJK426400WL TJK426T400
400A Frame—Three-Pole
125 375 1250 TJK436125WL THJK436125WL TJK436T125
150 450 1500 TJK436150WL THJK436150WL TJK436F000 TJK436T150
175 525 1750 TJK436175WL THJK436175WL Standard TJK436T175
200 600 2000 TJK436200WL THJK436200WL Frame TJK436T200
225 675 2250 TJK436225WL THJK436225WL TJK436T225 TCAL433 (1) 6-600
250 750 2500 TJK436250WL THJK436250WL TJK436T250 or
300 900 3000 TJK436300WL THJK436300WL TJK436T300 (2) 2/0-250 Cu/Al
350 1050 3500 TJK436350WL THJK436350WL THJK436F000 TJK436T350
400 1200 4000 TJK436400WL THJK436400WL Hi-Break TJK436T400
400 600 2000 — — TJK436TM14002
Mag 1200 4000 — — TJK436TM24002
Only 350 1000 — — TJK436TM34002
1For optional lugs, see page 6-106.
2Not UL listed.
3Alternate lug for 750 kcmil Cu/Al cable, Product Number TCAL47.
Types TJK, THJK — Interchangeable Trip, includes Cu/Al Line and Load Lugs, not suitable for reverse feed
Complete Circuit Breaker Terminal Lugs for Front
Includes Line and Load Lugs Connection (Cu/Al)1
Adjustable Instantaneous
Trip Ampere Frame Only Trip Unit Only. Use Product Number
Ampere Range Standard Hi-Break Product w/ Standard and (Order 2
Rating Low High Product Number Product Number Number Hi-Break Frames per pole) Wire Size
600A Frame—Two-Pole
250 750 2500 TJK626250WL THJK626250WL TJK626F000 TJK626T250 TCAL432 (1) 6-600
(1) 6-600
300 900 3000 TJK626300WL THJK626300WL TJK626F000 TJK626T300 or
Standard TCAL432 or
350 1050 3500 TJK626350WL THJK626350WL Standard
Frame TJK626T350 (2) 2/0-250 Cu/Al
(2) 2/0-250 Cu/Al
400 1200 4000 TJK626400WL THJK626400WL Frame
THJK626F000 TJK626T400
450 1350 4500 TJK626450WL THJK626450WL THJK626F000 TJK626T450 (2) 4/0-350
(2) 4/0-350 Cu
Cu
Hi-Break
500 1500 5000 TJK626500WL THJK626500WL Hi-Break TJK626T500 TCAL63 or
or
Frame
600 1800 6000 TJK626600WL THJK626600WL Frame TJK626T600 (2) 300-500
(2) 300-500 Al
Al
600A Frame—Three-Pole
250 750 2500 TJK636250WL THJK636250WL TJK636T250 TCAL432 (1) 6-600
(1) 6-600
300 900 3000 TJK636300WL THJK636300WL TJK636F000 TJK636T300 or
TCAL432 or
350 1050 3500 TJK636350WL THJK636350WL TJK636F000
Standard TJK636T350 (2) 2/0-250 Cu/Al
(2) 2/0-250 Cu/Al
400 1200 4000 TJK636400WL THJK636400WL Standard
Frame TJK636T400
450 1350 4500 TJK636450WL THJK636450WL Frame
THJK636F000 TJK636T450 (2) 4/0-350 Cu
500 1500 5000 TJK636500WL THJK636500WL THJK636F000
Hi-Break TJK636T500 TCAL63 (2) 4/0-350
or Cu
600 1800 600 TJK636600WL THJK636600WL Hi-Break
Frame TJK636T600 or
(2) 300-500 Al
TCAL63
600 6000 2000 — — Frame TJK636TM16003 (2) 300-500 Al
Mag
1800 6000 — — TJK636TM26003
Only
1For optional lugs, see page 6-106.
2Alternate lug for 750 kcmil Cu/Al cable, Product Number TCAL47
3Not UL listed.
Mounting Pole Inst. Mounting Pole Inst. Mounting Pole Inst. Mounting Pole Inst. Total Number of
Sheet Sheet Sheet Sheet Accessories Within any
Breaker Type L C R GEH- L R GEH- L R GEH- L R GEH- One Circuit Breaker
TQB, THQB,
One accessory only. Mounts
THHQB, TXQB,
4 in a one-inch frame and
TQL, THQL, UL — — — — — —
— — — — — increase overall breaker size
THHQL, TXQL,
by one pole. May be applied
TQC, THQC,
to 1-, 2-, or 3-pole breakers.
THHQC, TXQC
4
TQD, THQD — — — — — UL — — — — — — One accessory only
E150 TEB,
TEC, TED, 3418 2-pole circuit breaker—any
Aux one 3-pole circuit breaker—
THED, UL7 — UL 4576 — UL — UL 3417 — UL 8 3434
THLC1, 3416 any two except UVR and
S.T. 3-coil shunt trip
TB15,6,8
F225 9
TFC, TFJ, TFK,
THFK, THLC2, — — UL 4620 UL UL 4653 UL UL 4653 UL8 UL 4622 any two
THLC4, TLB2,
TLB4
J600 TJC, 3321
TJD, TJJ, Any two plus bell alarm except
Aux
TJK, THJK,
— UL 8 — 3320 UL UL
3435
— UL 5407 UL8 — 3346 TB4, TBC4 any one plus bell
alarm .
TB45, TBC45 S.T.
K1200 TKC, 3321
TKM, THKM Aux
— UL 8 — 4305 UL UL — UL 5408 UL8 — 3346 Any two plus bell alarm
TB65, TBC65 3344
TB8, TBC8 S.T.
Red Red
White Brown/white
Brown/white
Accessory-Lead Auxiliary Switch Blue All accessory contacts shown
with the circuit breaker in
Color Coding10 White tripped position.
Purple
Black Blue
Yellow Yellow
Brown Black Blue Black
Bell Alarm Switch Shunt Trip Undervoltage Release Three-Coil Shunt Trip
1 Except TFC and TFJ, F225 line model 4 frames and trips (mfg. code date J101+ (1981 or later), and THLC2, THLC4, TLB4 are UL listed for
field installation of most accessories.
2 Not UL listed.
3 600 Vac auxiliary switches are not UL listed.
4 Accessories are factory installed only.
5 UL listed at 200 AIC without internal accessories, 100 AIC with internally mounted accessories.
6 Accessories not available for single-pole TEB/TED frame. Use two-pole circuit breaker.
7 Left pole mounting not available for two-pole TEB, TED.
8 Not available with lead exit from the back of breaker.
9 UL listed interrupting capacity with accessories: 10 kAIC at 600 Vac, 22 kAIC at 480 Vac, 22 kAIC at 240 Vac.
10Leads are #18 125°C Vulkene insulated.
Auxiliary Switches
Unless otherwise noted switch is SPDT rated 6 amperes at rated ac voltage, 1/2 amperes at 125 Vdc, 1/4 amperes at 250 Vdc.
Control Voltage 240 Vac, 250 Vdc Maximum Control Voltage 600 Vac, 250 Vdc Maximum
UL Listed When Factory Installed Suffix1 Not UL Listed Suffix1
Number of Add to Base Product Add to Base Product
SPDT Switch Base Number for Factory Base Number for Factory
Breaker Type Elements Number Installation4 Number Installation4
TEB, TEC, TB1 1 TEDAS2AB1R,L2,3 S TEDAS6AB1R,L2,3 S
TED, THED,THLC13 2 TEDAS2AB2R,L2,3 S TEDAS6AB2R,L2,3 S
1 TJKASA2AB1R,L S TJKASA6AB1R,L S
2 TJKASA2AB2R,L S TJKASA6AB2R,L S
TJC, TJD, TJJ, TJK, THJK
3 TJKASA2AB3R,L S TJKASA6AB3R,L S
4 TJKASA2AB4R,L S TJKASA6AB4R,L S
1 TB4ASA2AB1R,L S TB4ASA6AB1R,L S
2 TB4ASA2AB2R,L S TB4ASA6AB2R,L S
TB4, TBC4
3 TB4ASA2AB3R,L S TB4ASA6AB3R,L S
4 TB4ASA2AB4R,L S TB4ASA6AB4R,L S
1 TKMAAS2AB1 RS or LS TKMAAS6AB1 RS or LS
TKM, THKM, TKC, TB6, 2 TKMAAS2AB2 RS or LS TKMAAS6AB2 RS or LS
TB8, TBC6, TBC8 3 TKMAAS2AB3 RS or LS TKMAAS6AB3 RS or LS
4 TKMAAS2AB4 RS or LS TKMAAS6AB4 RS or LS
1"S" suffix for wires out the side of breaker. For lead exit from back of breaker, replace suffix "S" with "B" and multiply list price by 1.25. "B" suffix not UL listed. Not available
with leads out the back for "Q-Line", or 2 element auxiliary switches used on TFG, TFJ, TFK, THFK, THLC2, THLC4, TLB2, and TLB4.
2Auxiliary switch mounts in right pole only on two-pole TEB, TED breakers. (Factory installed only.)
3Not available with “B” suffix–leads out back.
4For factory installation, contact Customer Service Center.
How to Order
For field replacement, order base number only. For factory installation, contact Customer
Service Center and order base number plus appropriate suffix. For a nonautomatic breaker
(molded case switch) a dummy trip is required when installing either a shunt trip or UVR.
Shunt Trip
Remote Tripping – Trips breaker by remote control. Trip coil de-energized when breaker
opens. Device meets UL requirements for service to ground fault system.
Undervoltage Release
Undervoltage release automatically trips breaker when applied coil voltage drops to
30 to 70 percent of rated value. Time-delay unit prevent nuisance tripping due to
momentary loss of voltage. Separate externally mounted unit has 120 Vac input and
125 Vdc output. Used in conjunction with 125 Vdc undervoltage release which must be
ordered separately. Product number SPUVTD for adjustable delay .1 to 1.0 seconds.
Shunt Trip
Product Number1,2 — UL Listed When Factory Installed
Suffix Number3
Accessory Voltage Base Number Add to Base Product Number
Breaker Type Vac Vdc for Field Replacement for Factory Installation
120 TEDST12 RS
240 TEDST12 RS
480 TEDST13 RS
600 TEDST13 RS
TEB, TEC, TB1-B4,
12 TEDST7 RS
TED, THED, THLC1
24 TEDST8 RS
48 TEDST9 RS
125 TEDST12 RS
250 TEDST11 RS
120 TFKSTA121 RS or LS
240 TFKSTA121 RS or LS
480 TFKSTA131 RS or LS
600 TFKSTA131 RS or LS
TFC, TFJ, TFK, THFK, THLC2,
12 TFKSTA71 RS or LS
THLC4, TLB2, TLB4
24 TFKSTA81 RS or LS
48 TFKSTA91 RS or LS
125 TFKSTA121 RS or LS
250 TFKSTA111 RS or LS
1UL listed for field installation on TFC, TFJ, TFK, and THFK model 4 frames and trips (mfg. Code date J101 or later) and on THLC2, THLC4, TLB4.
2For replacement voltage suppressor on 120 Vac UVRs for F225 line, order Product Number 286A8062G1. for 120 Vac UVRs on all other breaker lines,
order Product Number 192A8300G1.
3"S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B". "B" suffix not UL listed.
Not available with leads out the back on "Q-Line." For factory installation, contact Customer Service Center.
4For TB1 with bolt-on limiters.
Undervoltage Release
Product Number1,2 — UL Listed When Factory Installed
Suffix Number3
Accessory Voltage Base Number Add to Base Product Number
Breaker Type Vac Vdc for Field Replacement for Factory Installation
120 TEDUV1 RS
240 TEDUV2 RS
480 TEDUV4 RS
600 TEDUV6 RS
TEB, TEC, TB1-B4
12 TEDUV7 RS
TED, THED, THLC1
24 TEDUV8 RS
48 TEDUV9 RS
125 TEDUV10 RS
250 TEDUV11 RS
120 TJUV1R S
240 TJUV2R S
480 TJUV4R S
600 TJUV6R S
TJC, TJD, TJJ, TJK, THJK 12 TJUV7R S
24 TJUV8R S
48 TJUV9R S
125 TJUV10R S
250 TJUV11R S
120 TKUV1R S
240 TKUV2R S
480 TKUV4R S
600 TKUV6R S
TKC, TKM, THKM, TB6,
12 TKUV7R S
TB8, TBC6, TBC85
24 TKUV8R S
48 TKUV9R S
125 TKUV10R S
250 TKUV11R S
1UL listed for field installation on TFC, TFJ, TFK, and THFK model 4 frames and trips (mfg. Code date J101 or later) and on THLC2, THLC4, TLB4.
2For replacement voltage suppressor on 120 Vac UVRs for F225 line, order Product Number 286A8062G1 for 120 Vac UVRs on all other breaker lines, order
Product Number 192A8300G1.
3"S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B". "B" suffix not UL listed. For factory installation, contact
Customer Service Center.
4For TB1 with bolt-on limiters.
5Not UL listed.
Dummy Trip1
Breaker Type Product Number
E150 Internal accessories for these noninterchangeable
FJ225 breakers require factory-installed dummy trips.
JJ400 Automatically supplied when accessories are ordered.
JK400 TJKYT3 (two-pole, three-pole)
JK600 TJKYT36 (two-pole, three-pole)
KM800 TKMAYT3 (two-pole, three-pole)
1Not UL listed when field installed.
2Add "B" suffix for leads exit from back of breaker. For factory installation, contact
Customer Service Center.
3Not available with “B” suffix – leads out back.
4Not available for two-pole TEB, TED. Order TEDBAR.
5Changes circuit breaker interrupting capacity to: 10kA @ 600 Vac, 22kA @ 480 Vac,
22kA @ 240 Vac, for TFC, TFJ, TFK and THFK only.
6UL listed for field installation.
7Mounts in center pole with leads out left side.
S E D A 2 4 A T 0030
1Adjustable Instantaneous with Tracking Short Time (Long Time established via Interchangeable Rating Plugs).
Note: This information is provided for interpreting product numbers (it should not be used to build product numbers).
SE150 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SED, SEH; 2-Pole, UL/CSA: 150A, 480 Vac Max., IEC 947-2: 160A, 415 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
SE150 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SEL, SEP2; 2-Pole, UL/CSA: 150A, 480 Vac Max., IEC 947-2: 160A, 415 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
SE150 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SED, SEH; 3-Pole, UL/CSA: 150A, 600 Vac Max., IEC 947-2: 160A, 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac UL 489 IC @480 Vac
Adj. Inst. 18kA 25kA
Ampere Trip Range Amps Product Current Product Product Product Wire
Rating Low High Number Sensor Number Number Number Range
15 43 182 SRPE30A15
20 58 254 SRPE30A20 30 SEDA36AT00302 SEHA36AT00302
25 73 332 SRPE30A25
30 87 415 SRPE30A30
40 118 501 SRPE60A40
50 148 637 SRPE60A50 60 SEDA36AT00602 SEHA36AT00602 12-3/0 Cu
60 178 777 SRPE60A60 TCAL18
70 206 863 SRPE100A70 12-3/0 Al
80 236 999 SRPE100A80 100 SEDA36AT0100 SEHA36AT0100
90 267 1138 SRPE100A90
100 297 1280 SRPE100A100
110 328 1426 SRPE150A110
125 374 1640 SRPE150A125 150 SEDA36AT0150 SEHA36AT0150
150 450 1991 SRPE150A150
SE150 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SEL, SEP1; 3-Pole, UL/CSA: 150A, 600 Vac Max., IEC 947-2: 160A, 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac UL 489 IC @480 Vac
Adj. Inst. 65kA 100kA
Ampere Trip Range Amps Product Current Product Product Product Wire
Rating Low High Number Sensor Number Number Number Range
15 43 182 SRPE30A15
20 58 254 SRPE30A20 30 SELA36AT00302 SEPA36AT00302
25 73 332 SRPE30A25
30 87 415 SRPE30A30
40 118 501 SRPE60A40
50 148 637 SRPE60A50 60 SELA36AT00602 SEPA36AT00602 12-3/0 Cu
60 178 777 SRPE60A60 TCAL18
70 206 863 SRPE100A70 12-3/0 Al
80 236 999 SRPE100A80 100 SELA36AT0100 SEPA36AT0100
90 267 1138 SRPE100A90
100 297 1280 SRPE100A100
110 328 1426 SRPE150A110
125 374 1640 SRPE150A125 150 SELA36AT0150 SEPA36AT0150
150 450 1991 SRPE150A150
1SEL, SEP UL current limiting.
2When used with 15-50A Rating Plug, UL listed for HID (high intensity discharge).
SE 150 Reference Publications
Note: All Spectra™ breakers UL listed as HACR type.
Plug-in Mounting Base GEH-4610
All Spectra™ breakers marked CE. Installation Instructions for
™
Spectra E-Frame Add-On Limiters DEH-4671
STDA Flange Handle GEH-5314
Rating Plug GEH-5549
Shunt Trip and Undervoltage Release GEH-5551
SE150 Add-on 3-Pole Limiters Spectra™ E-Frame Installation Instruction GEH-5591
Maximum Product kAIC Use With Breaker/ Auxiliary Switch and Bell Alarm GEH-5593
Ampere Rating Number @600 Vac MCP Frame TDR Operating Mechanism GEH-5609
150 SAXSEL36150 65 SEL TDM Operating Mechanism GEH-5611
150 SAXSEP36150 100 SEP Motor Operator GEH-5613
Mechanical Interlock GEH-5615
STDA Operating Mechanism GEH-5684
Spectra™ RMS Molded Case Circuit Breaker Accessories - Warning Labels GEH-5686
Spectra™ RMS Molded Case Circuit
Breaker Accessories - Operator Adapter Kits GEH-5688
Spectra™ RMS Molded Case Circuit Breaker Accessories - Lugs for SE150 GEH-5881
Cable Operator Mechanism GEH-6290
Lug GEJ-3051
Padlocking Device - Standard GEJ-3056
Back Connected Studs GEJ-3609
SE150 Outline Drawing 168D1109SH1
Add-On Limiters DEH-4671
Spectra™ RMS Circuit Breakers in Combination
with Cooper Bussman Distribution Block DET-781
1Adjustable Instantaneous with Tracking Short Time (Long Time established via Interchangeable Rating Plugs).
Note: This information is provided for interpreting product numbers (it should not be used to build product numbers).
SF250 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SFH; 2-Pole, UL/CSA: 250A, 480 Vac Max., IEC 947-2: 250A, 415 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac
Adjustable Instantaneous 35kA
Trip Ampere Range
Ampere Product Current Product Product Wire
Rating Low High Number Sensor Number Number Range
70 205 700 SRPF250A70
80 235 800 SRPF250A80
90 265 900 SRPF250A90
100 295 1000 SRPF250A100
110 325 1100 SRPF250A110 8-350 Cu
125 370 1250 SRPF250A125 250 SFHA24AT0250 TCAL29
150 440 1500 SRPF250A150 8-350 Al
175 515 1750 SRPF250A175
200 590 2000 SRPF250A200
225 665 2250 SRPF250A225
250 736 2500 SRPF250A250
SF250 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SFL, SFP2; 2-Pole, UL/CSA: 250A, 480 Vac Max., IEC 947-2: 250A, 415 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac UL 489 IC @480 Vac
Adjustable Instantaneous 65kA 100kA
Trip Ampere Range
Ampere Product Current Product Product Product Wire
Rating Low High Number Sensor Number Number Number Range
70 205 700 SRPF250A70
80 235 800 SRPF250A80
90 265 900 SRPF250A90
100 295 1000 SRPF250A100
110 325 1100 SRPF250A110 8-350 Cu
125 370 1250 SRPF250A125 250 SFLA24AT0250 SFPA24AT0250 TCAL29
150 440 1500 SRPF250A150 8-350 Al
175 515 1750 SRPF250A175
200 590 2000 SRPF250A200
225 665 2250 SRPF250A225
250 736 2500 SRPF250A250
2SFL, SFP UL current limiting.
SF250 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SFH; 3-Pole, UL/CSA: 250A, 600 Vac Max., IEC 947-2: 250A, 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac
Adjustable Instantaneous 35kA
Trip Ampere Range
Ampere Product Current Product Product Wire
Rating Low High Number Sensor Number Number Range
70 205 700 SRPF250A70
80 235 800 SRPF250A80
90 265 900 SRPF250A90
100 295 1000 SRPF250A100
110 325 1100 SRPF250A110 8-350 Cu
125 370 1250 SRPF250A125 250 SFHA36AT0250 TCAL29
150 440 1500 SRPF250A150 8-350 Al
175 515 1750 SRPF250A175
200 590 2000 SRPF250A200
225 665 2250 SRPF250A225
250 736 2500 SRPF250A250
SF250 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SFL, SFP1; 3-Pole, UL/CSA: 250A, 600 Vac Max., IEC 947-2: 250A, 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac UL 489 IC @480 Vac
Adjustable Instantaneous 65kA 100kA
Trip Ampere Range
Ampere Product Current Product Product Product Wire
Rating Low High Number Sensor Number Number Number Range
70 205 700 SRPF250A70
80 235 800 SRPF250A80
90 265 900 SRPF250A90
100 295 1000 SRPF250A100
110 325 1100 SRPF250A110 8-350 Cu
125 370 1250 SRPF250A125 250 SFLA36AT0250 SFPA36AT0250 TCAL29
150 440 1500 SRPF250A150 8-350 Al
175 515 1750 SRPF250A175
200 590 2000 SRPF250A200
225 665 2250 SRPF250A225
250 736 2500 SRPF250A250
1SFL, SFP UL current limiting.
SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGD, SGH; UL/CSA: 400A, 600 Vac Max., IEC 947-2: 400A, 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac UL 489 IC @480 Vac
Adjustable
Instantaneous 65kA (240 Vac) 35kA
Trip Ampere Range
Ampere Product Current Product Product Product Wire
Rating Low High Number Sensor Poles Number Number Number Range
125 380 1275 SRPG400A125 2-pole lug kit
150 455 1530 SRPG400A150 (2) 2/0-500 Cu
175 530 1785 SRPG400A175 2 SGDA22AT04003 SGHA26AT0400 TCLK2654 or
200 605 2040 SRPG400A200 (1) 8-600 Cu
225 680 2295 SRPG400A225 400
250 755 2550 SRPG400A250 3-pole lug kit
300 905 3060 SRPG400A300 (2) 2/0-500 Al
3 SGDA32AT04003 SGHA36AT0400
350 1060 3570 SRPG400A350 TCLK3654 or
400 1210 4080 SRPG400A400 (1) 8-600 Al
SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGL, SGP5; UL/CSA: 400A, 600 Vac Max., IEC 947-2: 400A, 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac UL 489 IC @480 Vac
Adjustable
Instantaneous 65kA 100kA
Trip Ampere Range
Ampere Product Current Product Product Product Wire
Rating Low High Number Sensor Poles Number Number Number Range
125 380 1275 SRPG400A125 2-pole lug kit
150 455 1530 SRPG400A150 (2) 2/0-500 Cu
175 530 1785 SRPG400A175 2 SGLA26AT0400 SGPA26AT0400 TCLK2654 or
200 605 2040 SRPG400A200 (1) 8-600 Cu
225 680 2295 SRPG400A225 400
250 755 2550 SRPG400A250 3-pole lug kit
300 905 3060 SRPG400A300 (2) 2/0-500 Al
3 SGLA36AT0400 SGPA36AT0400
350 1060 3570 SRPG400A350 TCLK3654 or
400 1210 4080 SRPG400A400 (1) 8-600 Al
SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGH, SGL5; UL/CSA: 600A, 600 Vac Max., IEC 947-2: 630A, 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac UL 489 IC @480 Vac
Adjustable
Instantaneous 35kA 65kA
Trip Ampere Range
Ampere Product Current Product Product Product Wire
Rating Low High Number Sensor Poles Number Number Number Range
250 765 2530 SRPG600A250 2-pole lug kit
300 915 3035 SRPG600A300 (2) 2/0-500 Cu
2 SGHA26AT0600 SGLA26AT0600
350 1070 3545 SRPG600A350 TCLK2654 or
400 1220 4050 SRPG600A400 600 (1) 8-600 Cu
450 1375 4555 SRPG600A450 3-pole lug kit
500 1525 5060 SRPG600A500 3 SGHA36AT0600 SGLA36AT0600 (2) 2/0-500 Al
600 1830 6075 SRPG600A600 TCLK3654 or (1) 8-600 Al
3Rated 240 Vac max.
4Order one kit for either line or load end; two kits required for both.
5SGL, SGP UL current limiting.
Note: All Spectra™ breakers UL listed as HACR type. All Spectra™ breakers marked CE.
SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGP2; UL/CSA: 600A, 600 Vac Max., IEC 947-2: 630A, 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac
Adjustable
Instantaneous 100kA
Trip Ampere Range
Ampere Product Current Product Product Wire
Rating Low High Number Sensor Poles Number Number Range
250 765 2530 SRPG600A250 2-pole lug kit
300 915 3035 SRPG600A300 (2) 2/0-500 Cu
2 SGPA26AT0600
350 1070 3545 SRPG600A350 TCLK2651 or
400 1220 4050 SRPG600A400 600 (1) 8-600 Cu
450 1375 4555 SRPG600A450 3-pole lug kit
500 1525 5060 SRPG600A500 3 SGPA36AT0600 (2) 2/0-500 Al
600 1830 6075 SRPG600A600 TCLK3651 or (1) 8-600 Al
SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGH, SGL2; 100% UL Rated, 3-Pole: 400A, 600 Vac Max.; IEC 947-2: 400A, 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac UL 489 IC @480 Vac
Adjustable
Instantaneous 35kAIC 65kAIC
Trip Ampere Range
Ampere Product Current Product Product Product Wire
Rating Low High Number Sensor Poles Number Number Number Range
125 380 1275 SRPG400A125
150 455 1530 SRPG400A150 (2) 2/0-500 Cu
175 530 1785 SRPG400A175 or
200 605 2040 SRPG400A200 (1) 8-600 Cu
225 680 2295 SRPG400A225 400 3 SGHH36AT0400 SGLL36AT0400 TCLK3651
250 755 2550 SRPG400A250
300 905 3060 SRPG400A300 (2) 2/0-500 Al
350 1060 3570 SRPG400A350 or
400 1210 4080 SRPG400A400 (1) 8-600 Al
SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGP2; 100% UL Rated, 3-Pole: 400A, 600 Vac Max.; IEC 947-2: 400A, 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac
Adjustable
Instantaneous 100kAIC
Trip Ampere Range
Ampere Product Current Product Product Wire
Rating Low High Number Sensor Poles Number Number Range
125 380 1275 SRPG400A125
150 455 1530 SRPG400A150 (2) 2/0-500 Cu
175 530 1785 SRPG400A175 or
200 605 2040 SRPG400A200 (1) 8-600 Cu
225 680 2295 SRPG400A225 400 3 SGPP36AT0400 TCLK3651
250 755 2550 SRPG400A250
300 905 3060 SRPG400A300 (2) 2/0-500 Al
350 1060 3570 SRPG400A350 or
400 1210 4080 SRPG400A400 (1) 8-600 Al
1Order one kit for either line or load end; two kits required for both.
2SGL, SGP UL current limiting.
SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGH, SGL1; 100% UL Rated, 3-Pole: 600A, 600 Vac Max.; IEC 947-2: 630A, 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac UL 489 IC @480 Vac
Adjustable
Instantaneous 35kAIC 65kAIC
Trip Ampere Range
Ampere Product Current Product Product Product Wire
Rating Low High Number Sensor Poles Number Number Number Range
250 765 2530 SRPG600A250
300 915 3035 SRPG600A300 (2) 2/0-500 Cu
350 1070 3545 SRPG600A350 or (1) 8-600 Cu
400 1220 4050 SRPG600A400 600 3 SGHH36AT0600 SGLL36AT0600 TCLK3651
450 1375 4555 SRPG600A450 (2) 2/0-500 Al
500 1525 5060 SRPG600A500 (1) 8-600 Al
600 1830 6075 SRPG600A600
SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGP2; 100% UL Rated, 3-Pole: 600A, 600 Vac Max.; IEC 947-2: 630A, 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac
Adjustable
Instantaneous 100kAIC
Trip Ampere Range
Ampere Product Current Product Product Wire
Rating Low High Number Sensor Poles Number Number Range
250 765 2530 SRPG600A250
300 915 3035 SRPG600A300 (2) 2/0-500 Cu
350 1070 3545 SRPG600A350 or (1) 8-600 Cu
400 1220 4050 SRPG600A400 600 3 SGPP36AT0600 TCLK3651
450 1375 4555 SRPG600A450 (2) 2/0-500 Al
500 1525 5060 SRPG600A500 or (1) 8-600 Al
600 1830 6075 SRPG600A600
1Order one kit for either line or load end; two kits required for both.
2SGL, SGP UL current limiting.
SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL/CSA: 800A, 600 Vac Max., IEC 947-2:800A 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac UL 489 IC @480 Vac
Adjustable
Instantaneous 50kA 65kA
Trip Ampere Range
Ampere Product Current Product Product Product Wire
Rating Low High Number Sensor Poles Number Number Number Range
300 940 3015 SRPK800A300
400 1255 4015 SRPK800A400 2 SKHA26AT0800 SKLA26AT0800 (3) 3/0-500 Cu
500 1570 5020 SRPK800A500 800 TCAL81
600 1875 6195 SRPK800A600
700 2155 7420 SRPK800A700
3 SKHA36AT0800 SKLA36AT0800 (3) 3/0-500 Al
800 2440 8705 SRPK800A800
SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL/CSA: 800A, 600 Vac Max., IEC 947-2:800A 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac
Adjustable
Instantaneous 100kA
Trip Ampere Range
Ampere Product Current Product Product Wire
Rating Low High Number Sensor Poles Number Number Range
300 940 3015 SRPK800A300
400 1255 4015 SRPK800A400 2 SKPA26AT0800 (3) 3/0-500 Cu
500 1570 5020 SRPK800A500 800 TCAL81
600 1875 6195 SRPK800A600
700 2155 7420 SRPK800A700
3 SKPA36AT0800 (3) 3/0-500 Al
800 2440 8705 SRPK800A800
SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac UL 489 IC @480 Vac
Adjustable
Instantaneous 50kA 65kA
Trip Ampere Range
Ampere Product Current Product Product Product Wire
Rating Low High Number Sensor Poles Number Number Number Range
600 1825 6110 SRPK1200A600
700 2125 7125 SRPK1200A700 2 SKHA26AT1200 SKLA26AT1200 (4) 250-500 Cu
800 2430 8145 SRPK1200A800 1200 TCAL125
900 2735 9160 SRPK1200A900
1000 3040 10180 SRPK1200A1000
3 SKHA36AT1200 SKLA36AT1200 (4) 250-500 Al
1200 3650 12215 SRPK1200A1200
SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac
Adjustable
Instantaneous 100kA
Trip Ampere Range
Ampere Product Current Product Product Wire
Rating Low High Number Sensor Poles Number Number Range
600 1825 6110 SRPK1200A600
700 2125 7125 SRPK1200A700 2 SKPA26AT1200 (4) 250-500 Cu
800 2430 8145 SRPK1200A800 1200 TCAL125
900 2735 9160 SRPK1200A900
1000 3040 10180 SRPK1200A1000
3 SKPA36AT1200 (4) 250-500 Al
1200 3650 12215 SRPK1200A1200
SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
100% UL Rated, 3-Pole: 800A, 600 Vac Max.; IEC 947-2: 800A, 690 Vac Max.
Rating Plug Frame
UL 489 IC @480 Vac UL 489 IC @480 Vac UL 489 IC @480 Vac
Adjustable
Instantaneous 50kA 65kA 100kA
Trip Ampere Range
Ampere Product Current Product Product Product
Rating Low High Number Sensor Poles Number Number Number
300 940 3015 SRPK800A300
400 1255 4015 SRPK800A400
500 1570 5020 SRPK800A500 800 3 SKHH36AT0800 SKLL36AT0800 SKPP36AT0800
600 1875 6195 SRPK800A600
700 2155 7420 SRPK800A700
800 2440 8705 SRPK800A800
SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
100% UL Rated, 3-Pole: 1200A, 600 Vac Max.; IEC 947-2: 100A, 690 Vac Max.
Rating Plug Frame
UL 489 IC @480 Vac UL 489 IC @480 Vac UL 489 IC @480 Vac
Adjustable
Instantaneous 50kA 65kA 100kA
Trip Ampere Range
Ampere Product Current Product Product Product
Rating Low High Number Sensor Poles Number Number Number
600 1825 6110 SRPK1200A600
700 2125 7125 SRPK1200A700
800 2430 8145 SRPK1200A800 1200 3 SKHH36AT1000 SKLL36AT1000 SKPP36AT1000
900 2735 9160 SRPK1200A900
1000 3040 10180 SRPK1200A1000
1200 3650 12215 SRPK1200A1200 3 SKHH36AT12001 SKLL36AT12001 SKPP36AT12001
Other Features
—UL Listed for reverse feed and HACR type (standard)
—UL Listed 100% continuous current rating (optional)
—UL Listed Current Limiting (optional on SG Frame)
—Internal Accessories (Shunt Trip, Undervoltage Release, Auxiliary
Contacts, Bell Alarm) – UL Listed for field installation and
common across the entire line of Spectra™ RMS breakers
• • Metering (Basic)
• • Metering (Advanced)
• • • Modbus
• • Waveform Capture
Functions Accuracy and Description • Protective Relays
PC 2
PC 1
—Select the appropriate breaker frame on the following pages
taking into consideration the maximum ampere rating, the
interrupt rating, whether or not a 100% rating is required, RELT
Junction Breaker
standard protection functions (LSI, LSIG, LSIA), advanced protec- Box Cable
Communications
tion functions (Neut. Prot., ZSI, RELT), and advanced features and
communications (basic or advanced metering, communications,
TIM 1
TIM 1
(ZSI)
waveform capture, protective relays)
—Select the rating plug and breaker lugs from the tables provided. From To
—Select the required power management system accessories. Breaker Breaker
To Other Junction Boxes
Neutral
—Select other accessories as required (such as an auxiliary switch Current
Sensor
or shunt trip).
—When ordering, specify separate product numbers for each item Trip Unit Function Definitions
Long-Time (L) Adjustable current setting
Adjustable long-time delay - three curve shapes
Ordering Example (MVT I2t, CB and Fuse I4t)
Short-Time (S) Adjustable short-time pickup (can also be turned OFF)
SG600 ampere frame, standard load rating and 400 maximum Adjustable short-time delay - multiple slope options
ampere rating, 350 amp rating plug with line and load lugs. Trip I2t IN or OUT
Instantaneous (I) Adjustable instantaneous pickup
functions to include adjustable long-time (L), short-time (S), Ground Fault (G) Adjustable ground fault pickup
instantaneous (I), ground fault alarm (A), reduced energy let- Ground Fault Alarm (A) Adjustable ground fault delay - multiple slope options
through (RELT), and advanced metering, communications, with I2t IN or OUT
Control Power (CP) +24Vdc control power connection
waveform capture and protective relays. Metering and communi- Trip Indication Targets Standard
cations of voltage, current, power and breaker contact position Neutral Protection Adjustable current setting on Neutral: multiple of
are required. Local RELT enable is also required. The available Long-Time setting
ZSI (ST/GF/INST) Adjustable Zone Selective Interlock settings for
system voltage is 480/277 Vac 3 phase/4-wire with an available Short-Time, Ground Fault, and Instantaneous
fault current of 65kAIC. Power management accessories are to be RELT Adjustable Instantaneous: Reduced Energy
Let-Through mode
mounted on plates with all of the necessary fuse protection, Metering (basic) Amperes (A/kA) - Phase selectable
potential transformers, control power transformers, and required Metering (advanced) Current (A/kA) - Phase selectable
interconnect accessories. The required circuit breaker Product Voltage (V) - L-L or L-N and Phase selectable
Real Power (kW) - L-L or L-N
Number is SGLC3604L5R8. Reactive Power (kVAR) - L-L or L-N
Apparent Power (kVA) - L-L or L-N
Peak Power Demand (kW)
Description Product Number Energy (kWh/MWh)
Frequency (Hz)
Breaker Prefix SGLC3604L5_ _ Power Factor (%)
Adder 1 for R (RELT) Communications Modbus with user selectable address assignment
Adder 2 for 8 Compatible with EnerVista Viewpoint power system
(Adv Meter/Modbus/WFC/Relay) monitoring software
Complete Breaker SGLC3604L5R8 Waveform Capture Stores 8 cycles of data on trip or signal
Rating Plug GTP0350U0408 (COMTRADE file format)
Lug Kits (2) TCLK365 Protective Relay Functions Voltage Unbalance - pickup/delay/OFF
Auxiliary Switch SAUXGAB1 Current Unbalance - pickup/delay/OFF
RELT Switch Kit GTURSK Under Voltage - pickup/delay/OFF
Power Supply Plate SPSA480 Over Voltage - pickup/delay/OFF
Voltage Conditioner Plate SVCA480Y Power Reversal - pickup/delay/OFF
Advanced J-Box SDCJBBC Load Alarm - pickup (ON)/OFF
Distribution Cable Harness (2) SDCHA11
400A Neutral CT TSRG204
Other Features/Functions
HMI - Backlit LCD display & Ease of programming and viewing status/
5-button keypad metering displays, tactile feel
LED Status Indicator Visual display of trip unit’s “health”
Visual pickup waring signal For quick diagnostics and pre-trip detection
Sealable LEXAN cover for Tamper resistant settings
tamper resistant settings
Test set jack for GTURSK test kit Fully integrated with GTURSK test kit
Long Time Thermal Memory For enhanced system protection
Input Relay1 Dedicated if RELT enabled or set to TRIP/OFF
Qty (2) Programmable Output Contacts1 RELT (dedicated)
Ground Fault Alarm
Overcurrent Trip
Protective Relay Trip
Load Alarm
Health Status
1Included on breakers with 20-pin output harness
Instantaneous Selectivity
System/Asset Protection
Diagnostics/Reliability
System Performance
Coordination
Arc Flash
Feature Benefit
Enhanced adjustability and flexibility Enhanced system protection via tight coordination with upstream
• • •
of time current curve shape, slope, and delay bands and downstream devices including fuses
Ground Fault Trip or Alarm Enhanced system and asset protection - especially for process driven applications • •
Zone Selective Interlock (ST/GF) System protection • •
Zone Selective Interlock (Instantaneous) Maximum system protection, coordination, and selectivity • • •
Reduced Energy Let-Through Enhanced system and personnel protection • • •
Protective Relay Functions Enhanced system and asset protection via a suite of protective relays •
Neutral Protection Protection on heavy harmonic loads •
Sealable LEXAN Trip Unit Cover Prevents unauthorized trip unit setting changes for maximum system, personnel,
• •
and asset protection.
Long Time Thermal Memory Enhanced system protection •
Input Relay1 System and asset protection via remote trip (dedicated if RELT enabled) •
Programmable Output Contacts1 Maximize system uptime via signaling on GF alarm, overcurrent trip, protective relay trip,
• •
load alarm or health status
Advanced Metering System performance monitoring and diagnostics of critical current, voltage,
• •
and power characteristics
Modbus Communications System performance monitoring, reporting and diagnostics (compatible with
• • •
EnerVista Viewpoint power system monitoring software)
Test Set Jack for GTUTK20 Test Kit Maximize system uptime and enhanced diagnostics via the GTUTK20 test kit •
Trip Indication Targets Visual Trip indication for quick diagnostic evaluation •
Event Log Records last 10 trip events •
Waveform Capture Enhanced diagnostic feature to maximize system uptime •
HMI - Backlit LCD Display and 5-button Keypad Ease of programming and viewing status/metering displays •
LED Status Indicator Enhanced diagnostic feature to maximize system uptime
•
(visual display of trip unit’s “health”)
Visual Pickup Warning Signal For quick diagnostics and pre-trip detection •
Spectra™ microEntelliGuard™
Reference Publications
Molded Case Circuit Breaker Accessories -
Distribution Cable Junction Box SDCJBB DEH-006
Spectra™ G Breaker w/
microEntelliGuard™ Trip Unit GEH-700
Spectra™ K Breaker w/
microEntelliGuard™ Trip Unit GEH-701
microEntelliGuard™ Trip Unit Users Manual GEH-702
Universal Rating Plug DEH-41318
Voltage Module GEH-6250
Power Supply Plate GEH-6251
Voltage Conditioner Plate GEH-6252
Power Supply Assembly GEH-6253
Voltage Conditioner Assembly GEH-6254
microEntelliGuard™ Jump Start
Programming Instructions GEH-703
MET Advanced Distribution Cable Junction Box GEH-704
Distribution Cable Junction Box DEH-006
MET Distribution Cable Extension (20-pin) GEH-705
Distribution Cable Extension (12-pin) GEH-6256
Distribution Cable Harness (12-pin) GEH-6255
MET Distribution Cable Terminal Blocks
(11 point & 22 point) GEH-706
Distribution Cable Terminal Block (11 point) GEH-6257
MET Sealable Cover Kits GEH-707
GTU Digital Test Kit (GTUTK20) DEH-4568
Shunt Trip and UVR Instructions GEH-5551
Aux Switch and Bell Alarm GEH-5593
Spectra™ RMS Molded Case Circuit Breaker
Accessories - Door Ring Interlock Catch Kits GEI-70594
TIM-1 Zone Selective Interlock Module GEK-64467
Standard
Frame Rating Voltage Protection Advanced Features &
Family (Amperes) Poles Rating Functions Communications
S = Spectra™ G = 600 3 = 3 poles 6 = 600V L3 = LSI2 X = Metering (Basic)
L4 = LSIG 2 = Metering (Basic) +
L5 = LSIA Modbus
Continuous
L7 = LSI-CP3 6 = Metering (Adv) +
Load Rating
Modbus +
C = Standard Waveform Capture
H = 100% Max Amps 8 = Metering (Adv) +
L = 100% 01 = 150A Modbus +
P = 100% 04 = 400A Waveform Capture +
06 = 600A Protective Relays
Interruption Rating
(kA @ 480V)
H = 35 Advanced Protection Functions
L = 65 X = None
P = 100 K = Neutral Protection
Z = ZSI (ST/GF)
T = ZSI (ST/GF/INST)
R = RELT
L = ZSI (ST/GF) + RELT
M = ZSI (ST/GF) +
Note: This information is provided for interpreting product numbers (it should not be used to build product numbers).
L = Long Time, S = Short Time, I = Instantaneous, G = Ground Fault, A = Ground Fault Alarm
Neutral Protection
ZSI = Zone Selective Interlocking, RELT = Reduced Energy Let-Through N = ZSI (ST/GF) + RELT +
Neutral Protection
2Without a Control Power connection, unless required by Advanced Protection Functions or Advanced Features
V = RELT + Neutral Protection
& Communications. P = ZSI (ST/GF/INST) + RELT
3With a Control Power connection. The only valid trailing product digits for L7 are XX.
S = ZSI (ST/GF/INST) +
Note: All Spectra™ breakers are UL listed as HACR type. Neutral Protection
W = ZSI (ST/GF/INST) + RELT +
Neutral Protection
1May require 24 Vdc control power and voltage sensing Notes: All Spectra™ breakers are UL listed as HACR type.
signals. Refer to pages 6-62 to 6-68. Neutral Protection requires a neutral current sensor. Refer to page 6-66.
2For grounded neutral systems (1 phase/3-wire or ZSI (Zone Selective Interlock) requires TIM1 ZSI module and 24 Vdc control power (refer to pages 6-62 to
3 phase/4-wire) a neutral current sensor is required. 6-66 for accessories).
Refer to page 6-66. RELT (Reduced Energy Let-Through), Modbus, Ground Fault Alarm and Waveform Capture options require
3For +24 Vdc Control Power Accessories refer to pages 24 Vdc control power
6-62 to 6-66. (refer to pages 6-62 to 6-66 for accessories).
Standard
Frame Rating Voltage Protection Advanced Features &
Family (Amperes) Poles Rating Functions Communications
S = Spectra™ K = 1200 3 = 3 poles 6 = 600V L3 = LSI3 X = Metering (Basic)
4 = 480V5 L4 = LSIG 2 = Metering (Basic) +
L5 = LSIA Modbus
Continuous
L7 = LSI-CP4 6 = Metering (Adv) +
Load Rating
Modbus +
C = Standard Waveform Capture
H = 100% Max Amps 8 = Metering (Adv) +
L = 100% 08 = 800A Modbus +
P = 100% 10 = 1000A2 Waveform Capture +
S = 100% 12 = 1200A Protective Relays
T = 100%
Interruption Rating
(kA @ 480V) Advanced Protection Functions
H = 50 X = None
L = 65 K = Neutral Protection
P = 100 Z = ZSI (ST/GF)
T = 65 Extended Instantaneous (Selective)5 T = ZSI (ST/GF/INST)
S = 100 Extended Instantaneous (Selective)5 R = RELT
L = ZSI (ST/GF) + RELT
M = ZSI (ST/GF) +
Note: This information is provided for interpreting product numbers (it should not be used to build product numbers).
Neutral Protection
L = Long Time, S = Short Time, I = Instantaneous, G = Ground Fault, A = Ground Fault Alarm
ZSI = Zone Selective Interlocking, RELT = Reduced Energy Let-Through N = ZSI (ST/GF) + RELT +
Neutral Protection
2Max Amps Option 10 only available on 100% rated breakers. V = RELT + Neutral Protection
3Without a Control Power connection, unless required by Advanced Protection Functions or Advanced Features
P = ZSI (ST/GF/INST) + RELT
& Communications.
4With a Control Power connection. The only valid trailing product digits for L7 are XX.
S = ZSI (ST/GF/INST) +
5SC, SS, TC and TT catalog codes are optimized for selectivity (extended instantaneous) and will carry a 480 Vac Neutral Protection
maximum voltage rating. W = ZSI (ST/GF/INST) + RELT +
Neutral Protection
Note: All Spectra™ breakers are UL listed as HACR type.
Required Accessories
MicroVersaTrip™ Plus MicroVersaTrip™ PM microEntelliGuard™ Feature Required Accessories
• • • Ground Fault (3 phase/4-wire or 1 phase/3-wire) Neutral CT and Terminal Board
• Neutral Protection (or Junction Box + Distribution Cable)
• Ground Fault Alarm (3 phase/4-wire or 1 phase/3-wire) Power Supply (Plate Assy2)
• • • Control Power Voltage Module1 or Power Supply Plate/Assy2
Power Supply (Plate or Assy2) and Voltage Conditioner
• • Advanced Metering, Protective Relays (Plate or Assy) or Voltage Module and
Terminal Board (or Junction Box) and Distribution Cable(s)
Voltage Module1 or Power Supply Plate/Assy2 and
• • Communications3 Terminal Board (or Junction Box) and Distribution Cable(s)
and Auxiliary Switch4
Voltage Module1 or Power Supply Plate/Assy2 and
• Zone Selective Interlock (ZSI) Terminal Board with ZSI (or Advanced Junction Box)
and Distribution Cable(s) and TIM-1 module
Voltage Module1 or Power Supply Plate/Assy2 and
• Reduced Energy Let-Through (RELT) Terminal Board w/ RELT (or Advanced Junction Box)
and Distribution Cable(s)
Voltage Module1 or Power Supply Plate/Assy2 and
• Waveform Capture Terminal Board (or Advanced Junction Box)
and Distribution Cable(s)
1For installation into GE Spectra™ Series Switchboards only 3MicroVersaTrip™ PM (Commnet), microEntelliGuard™ (Modbus)
2Requires fuse protection and other components - refer to accessory instruction sheet 4Requires Auxiliary Switch with gold-plated contacts
Note: The Voltage Conditoner Plate has the maximum capacity to power a Distribution Cable System consisting of
20 breakers and has a maximum system cable length of 40 feet.
Breakers with microEntelliGuard™ Trip Units Distribution Cable Terminal Block Connection Configurations
Breaker Harness Connector Configuration Terminal SDCTBA11 SDCTBA11C SDCTBA22C
Description 12-pin Connector 20-pin Connector 20-pin Connector
Circuit Breaker Catalog Digits 9 & 10
MicroVersaTrip™ & microEntelliGuard™ microEntelliGuard™
L3 L4 L5 L7
Trip Unit Type microEntelliGuard™ only only
K2 SDCTBA11 SDCTBA11 SDCTBA22C n/a
POWER (+24Vdc) • • •
K6 SDCTBA11 SDCTBA11 SDCTBA22C n/a
POWER (common) • • •
K8 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Communications + • •
KX SDCTBA11 SDCTBA11 SDCTBA11C n/a
Communications - • •
L2 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Aux Switch (red) • •
L6 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Aux Switch (white) • •
L8 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Voltage - Ph A • •
LX SDCTBA22C SDCTBA22C SDCTBA22C n/a
Voltage - Ph B • •
M2 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Voltage - Ph C • •
M6 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Neutral CT (black) • • •
M8 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Neutral CT (white) • • •
MX SDCTBA22C SDCTBA22C SDCTBA22C n/a
ZSI input + •
N2 SDCTBA22C SDCTBA22C SDCTBA22C n/a
ZSI input - •
N6 SDCTBA22C SDCTBA22C SDCTBA22C n/a
ZSI output + •
N8 SDCTBA22C SDCTBA22C SDCTBA22C n/a
ZSI output - •
NX SDCTBA22C SDCTBA22C SDCTBA22C n/a
RELT input + • •
P2 SDCTBA22C SDCTBA22C SDCTBA22C n/a
RELT input - • •
P6 SDCTBA22C SDCTBA22C SDCTBA22C n/a
RELT output + • •
Circuit Breaker Catalog Digits 11 & 12
Note: the Voltage Conditioner Assembly has the maximum capacity to power a Distribution Cable System
consisting of 20 breakers and has a maximum system cable length of 40 feet.
Voltage Modules
The Voltage Module is used as a Spectra™ Series Switchboard component to provide
+24 Vdc control power to Spectra™ RMS molded case circuit breakers with
microEntelliGuard™, MicroVersaTrip™ Plus and MicroVersaTrip™ PM trip units via the
Distribution Cable System. The Voltage Module also provides voltage sensing signals to
Spectra™ RMS molded case circuit breakers with microEntelliGuard™ and MicroVersaTrip™
PM trip units on the same Distribution Cable System. The Voltage Module contains both
a Power Supply Plate and a Voltage Conditioner as integral components. It also includes
fuse protection for the AC source input terminals (the module’s pressure connectors
which connect to the switchboard bus bars). A communication network connection is
provided as well as supplemental +24 Vdc input terminals for backup control power Voltage Module Exterior View
applications (microEntelliGuard™ trip units communicate via Modbus; MicroVersaTrip™ PM
communicate via Commnet). Seven versions are available. Not suitable for 400 Hz.
Voltage Rating and Service Type Comments Product Number
120 Vac Wye system Phase to Neutral potential ADSVMA120Y
208 Vac Wye system Phase to Phase potential ADSVMA208Y
240 Vac Delta system Phase to Phase potential ADSVMA240D
277 Vac Wye system Phase to Neutral potential ADSVMA277Y
480 Vac Wye system Phase to Phase potential ADSVMA480Y
480 Vac Delta system Phase to Phase potential ADSVMA480D
600 Vac Delta system Phase to Phase potential ADSVMA600D
Note: The Voltage Module has the maximum capacity to power a Distribution Cable System consisting of 20
breakers and has a maximum system cable length of 40 feet.
Voltage Module Interior View
Accessory Mounting
All accessories mount in pouches accessible from a front cover. All breakers have a
left-side pouch and right-side pouch. The following combinations may be installed:
Left-Side Pouch—either shunt trip or undervoltage release plus bell alarm. Left Side Pouch Right Side Pouch
Right-Side Pouch—auxiliary switch (single or double pole).
Auxiliary Switch
Auxiliary switches provide remote indication of whether the circuit breaker main
contacts are opened or closed via open or closed SPDT switch elements.
Switch Number of Auxiliary Switch
Rating Switch Elements Product Number
5A @240 Vac/ 1 form C SAUXPAB1
0.5A @ 125 Vdc 2 form C SAUXPAB2
Gold-Plated Contacts 1 form C SAUXGAB1
0.5A @ 30V 2 form C SAUXGAB2
One each 2 form C SAUXGPAB2
of above types
Auxiliary Switch
Red
All accessory contacts shown
White with the circuit breaker in
Brown/white tripped position.
For remote tripping of breaker, use with momentary close contact. Not recommended for
use with latching relay contact since electronics in shunt trip will pulse power to the coil
if continuously energized, and breaker shunt tripping upon reclosure will be delayed 1-2
seconds at rated control voltage. (A short-circuit trip would be instantaneous.)
If maintained (latching relay) contact must be used and delayed shunt tripping is not
acceptable, use small bell alarm in series with control power for SE150 and SF250 frames
and auxiliary switch for SG600 and SK1200 breakers.
These devices are suitable for use with ground fault sensing and relaying equipment.
Maximum VA is 75. AC devices are UL listed for 50-60 Hz.
Undervoltage Release
The undervoltage release provides automatic circuit breaker tripping when there is a
power loss or major dip (to 35%-70% of rated voltage) in accessory control voltage. AC
devices are UL listed for 50-60 Hz. Product number SAUV1 may be used with time delay
unit SPUVTD (List Price $430.00, GO-245B) (delay 0.1 to 1.0 seconds), 120 Vac input,
125 Vdc output.
Note: UL listed at 200,000 AIC without internal accessories, 100,000 AIC with internally mounted accessories.
Purple
Yellow All accessory contacts shown
with the circuit breaker in
Brown tripped position.
Actuator
All Spectra™ circuit breakers are supplied with an actuator installed in the left-side pouch.
The actuator is removed when installing either a shunt trip or undervoltage release.
Description Product Number
Replacement Actuator SACTUATOR
Trip Curves
Trip Unit Rated Current (A) Trip Curve
15 DES-013
FB Breaker Markings 20 DES-014
cULus UL File E-11592 25 DES-015
30 DES-016
HACR 15 to 100A 1, 2, 3 Pole
35 DES-017
HID 15 to 50A 1, 2, 3 Pole
40 DES-018
NAVAL 15 to 100A 1, 2, 3 Pole
45 DES-019
Cu/Al 60/75°C 15 to 100A 1, 2, 3 Pole
50 DES-020
Current Limiting 15 to 100A 1, 2, 3 Pole
60 DES-021
FB breakers are NOT marked LINE/LOAD and can be reverse fed. 70 DES-022
80 DES-023
90 DES-024
100 DES-025
Peak Current Curves DES-030
Peak I2t Curve DES-031
Interrupting Ratings
UL Listed Interrupting Ratings -
rms Symmetrical Amperes (in Thousands) AC Voltage
Type Ampere Rating Max AC Voltage No. Poles 240 277 347 480 600/347
1 35 35 22 – –
FBV 15-100 600/347VAC 2 65 – – 35 22
3 65 – – 35 22
1 65 65 25 – –
FBN 15-100 600/347VAC 2 150 – – 65 25
3 150 – – 65 25
1 100 100 35 – –
FBH 15-100 600/347VAC 2 200 – – 100 35
3 200 – – 100 35
1 100 150 42 – –
FBL 15-100 600/347VAC 2 200 – – 150 42
3 200 – – 150 42
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads
(#18 AWG). Shunt trip wire leads are black and UVR wire leads are blue.
Bell Alarm
Contact
Configuration Contacts Contact Rating Wire leads Product No.
1 NO (Form A) Standard 5A @ 277 VAC, 0.3A @ 125 VDC #16 AWG FABAM10W
1 NC (Form B) Standard 5A @ 277 VAC, 0.3A @ 125 VDC #16 AWG FABAM01W
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference
instruction sheet DEH-40324 for wire lead colors.
Auxiliary Switches
Contact Left Mount Right Mount
Configuration Contacts Contact Rating Wire leads Product No. Product No.
1 NO (Form A) Standard 5A @ 277 VAC, #16 AWG FAS10LW FAS10RW
0.3A @ 125 VDC
1 NC (Form B) Standard 5A @ 277 VAC, #16 AWG FAS01LW FAS01RW
0.3A @ 125 VDC
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference
instruction sheet DEH-40324 for wire lead colors.
2 pole 3 pole
Mounting Locations
Padlocking Devices
Description Product No.
Padlock Fixed Toggle FB1PF
Padlock EUSERC Toggle FB1PE
FB 100 Dimensions
Poles A B C D E F G1 G2 H
1 3.88 (98.6) 3.28 (83.3) 1.06 (26.9) 1.36 (34.5) N/A N/A 5.11 (129.8) 5.01 (127.3) 6.45 (163.8)
2 3.88 (98.6) 3.28 (83.3) 1.06 (26.9) 2.74 (69.6) 0.69 (17.5) 1.38 (35.1) 5.11 (129.8) 5.01 (127.3) 6.45 (163.8)
3 3.88 (98.6) 3.28 (83.3) 1.06 (26.9) 4.11 (104.4) 1.38 (35.1) 1.38 (35.1) 5.11 (129.8) 5.01 (127.3) 6.45 (163.8)
"D" "A"
"D" "E" "E" "B"
"D" "F"
"E" "F" "C"
"G1"
"G1" "G1"
Reference Publications
Available for download from www.geindustrial.com/publibrary
1 Breaker Frame Rating FC Breaker
2 Installation Instructions DEH-40463
Rated Voltage
FC Breaker Accessories
3 Breaker Frame Bell Alarm & Aux. Switch DEH-40324
4 Enclosed Rating Shunt Trip & Undervoltage Release DEH-40363
4
5 Lug Kits DEH-40532
1 3 5
Product Description Outline Drawings
2 6 Standards FC 2-3 pole 10085772SH1
6 Series Ratings DET-008
7 Interruption Capacity
7
Product Number
Trip Curves
Trip Unit Rated Current (A) Trip Curve
15 DES-013
20 DES-014
25 DES-015
30 DES-016
35 DES-017
40 DES-018
45 DES-019
Main Standards 50 DES-020
—UL 489 60 DES-021
70 DES-022
—IEC 947 and associated EN Sections 80 DES-023
90 DES-024
100 DES-025
FC Breaker Markings Peak Current Curves DES-030
cULus UL File E-11592 Peak I2t Curve DES-031
HID 15-50A
HACR 15 to 100A
Cu/Al 60/75°C 15 to 100A
Current Limiting 15 to 100A
Record Plus™, Non-Automatic Circuit Breaker (Molded Case Switch), 600 VAC
2-Pole 3-Pole Lug Kit (3 per kit)
Ampere Rating Product No. Product No. Product No.
60 FCY206F060R FCY306F060R FCALK13
100 FCY206F100R FCY306F100R FCALK14
External Accessories
Electrical Operator Motor Drives,
Front Mounted Padlocking Devices
Voltage Product No. Motor Operator
Description Product No.
120 VAC/125 VDC FCEMF3
220/240 VAC, 50/60 Hz FCEMF6 Padlock Fixed Toggle FC1PF
48 VDC FCEMFF Padlock EUSERC Toggle FC1PE
Plug-In Types
Type Description Product No.
Complete Kits 3 Pole - LSL - Horizontal Strap FCDDF1
3 Pole - SLS - Horizontal Strap FCDDF2 Padlock
3 Pole - LSL - Vertical Strap FCDDF3
3 Pole - SLS - Vertical Strap FCDDF4
Secondary Disconnect Secondary Disconnect Kit FCDSD
Secondary Disconnect - Base Part FCDSDP
Secondary Disconnect - Breaker Part FCDSDB
Mounting Plate Mounting Plate FCDMP
Hardware Kits
Description Product No.
Plug-In Bases
Mounting screws for mounting plates with tapped holes, quantity 4 FCMSK3
(#8-32 x 2 7/8” screws with lockwashers)
Mounting screws for mounting plates with clearance holes, quantity 4 FCMSK4
(#8-32 x 3” screws with nuts lockwashers)
Nut plates (quantity 3) FCNP3
Nut plates (quantity 36) FCNPB
Plug-In Plate
C H
FC 100 Dimensions
Frame A B C D E F G H
FC 3.7 (29.1) 3.2 (81.3) .96 (24.4) 3.0 (76.2) 1.0 (25.4) 6.4 (162.6) 5.0 (127.0) 1.0 (25.4)
G F
Reference Publications
Available for download from www.geindustrial.com/publibrary
FE Breaker
1 Breaker Frame Rating Installation Instructions DEH-41640
2 Product Description Outline Drawing 10101247PV1
1 3 Standards & Markings FE Breaker Accessories
2 Bell Alarm & Aux Switch DEH-40324
4 Interrupting Ratings Shunt Trip & UVR DEH-40259
3 5 Lug Data & Torque Info Padlock Device DEH-41059
4 Lug Kits DEH-41054
6 Product Number
Auxiliary Contacts DEH-40261
5 7 Push to Trip Panelboards
7 6 Spectra™ Power Panel - Plug-in Kits DEH-40402
Spectra™ Power Panel - Bolt-on Kits DEH-40425
Series Ratings DET-008
External Operators
TDR Style DEH-41028
STDA Style DEH-41014
Cable Operator DEH-40912
TDM Style DEH-41025
Main Standards
Trip Curves
—UL /cUL 489 Record Plus FE with PremEon S Trip - LSI Protections DES-115
—HACR (heating, air conditioning, and refrigeration) Record Plus FE with PremEon S Trip - GF Protection DES-116
Record Plus FE with PremEon S Trip - Mag only Motor Circuit Protector DES-117
—Naval
Peak Current Curves DES-205
Peak l2t Curve DES-206
Interrupting Ratings
UL Listed Interrupting Ratings -
rms Symmetrical Amperes (in Thousands) AC Voltage
Type Ampere Rating Max Voltage No. Poles 240 480
2 150 65
FEN 25-250A 480VAC
3 150 65
2 200 100
FEH 25-250A 480VAC
3 200 100
Cross Reference
SMR1 Equipped FE MCCB Rating Plug Amps PremEon Equipped MCCB
FE(N/H)(2/3)4AA0025R 20, 25 FE(N/H)(2/3)4DB025KF
FE(N/H)(2/3)4AA0060R 25, 30, 40, 50, 60 FE(N/H)(2/3)4DB060KF
FE(N/H)(2/3)4AA0125R 50, 60, 70, 80, 90, 100 ,110 ,125 FE(N/H)(2/3)4DB125KF
FE(N/H)(2/3)4AA0150R 70, 80, 90, 100, 110, 125, 150 FE(N/H)(2/3)4DB150KF
FE(N/H)(2/3)4AA0250R 100, 110, 125, 150, 175, 200, 225, 250 FE(N/H)(2/3)4DB250KF
F E N 3 4 D B 250 K F
Interruption Connection
Family Frame Size Rating (@480VAC) Poles Voltage Trip Unit Type Trip Unit Protection Trip Unit Amps Frame Amps Configuration
F = Record Plus E = 250A N = 65kA 2 = 2-Pole 4 = 480VAC D = PremEon S1 B = LI 025 = 25A K = 250A F = Standard,
H = 100kA in 3-Pole Frame C = LI 400 Hz 060 = 60A No Lugs
3 = 3 Pole G = LIG 125 = 125A
w/ Ground Fault 150 = 150A
250 = 250A
M =Mag-Only MCP
P = Mag-Only MCP
w/ Ground Fault
FE Breakers and MCP's equipped with the PremEon trip unit do not
use Rating Plugs to determine Amp rating. The trip unit features
an adjustment knob to set the Amp rating (Long-Time Pickup).
The knob is located behind a sealable cover and requires a
tamper-resistant Torx T15 tool. The tool is available through many
industrial supply companies. The maximum Amp rating of the
breaker frame is shown in the "Current Sensor" column below.
The available Amp rating settings (LT Pickup values), by sensor, are
as follows:
LI Trip Unit (With Tracking Short-Time) LIG Trip Unit (With Tracking Short-Time)
2-Pole Record Plus FE Breakers 2-Pole Record Plus FE Breakers
65kAIC @ 480 Vac 100kAIC @ 480 VAC 65kAIC @ 480 Vac 100kAIC @ 480 VAC
Current Sensor (A) Product Number Product Number Current Sensor (A) Product Number Product Number
25 FEN24DB025KF FEH24DB025KF 25 FEN24DG025KF FEH24DG025KF
60 FEN24DB060KF FEH24DB060KF 60 FEN24DG060KF FEH24DG060KF
125 FEN24DB125KF FEH24DB125KF 125 FEN24DG125KF FEH24DG125KF
150 FEN24DB150KF FEH24DB150KF 150 FEN24DG150KF FEH24DG150KF
250 FEN24DB250KF FEH24DB250KF 250 FEN24DG250KF FEH24DG250KF
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads
(#18 AWG). Shunt trip wire leads are black and UVR wire leads are blue.
Bell Alarm
Contact
Configuration Contact Rating Wire leads Product No.
1 NO (Form A) 5A @ 277 VAC, #16 AWG FABAM10W
0.3A @ 125 VDC
1 NC (Form B) 5A @ 277 VAC, #16 AWG FABAM01W
0.3A @ 125 VDC
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference
instruction sheet DEH-40324 for wire lead colors.
Auxiliary Switches
Contact Left Mount Right Mount
Configuration Contact Rating Wire leads Product No. Product No.
1 NO (Form A) 5A @ 277 VAC, #16 AWG FAS10LW FAS10RW Bell Alarm
0.3A @ 125 VDC Mechanism
1 NC (Form B) 5A @ 277 VAC, #16 AWG FAS01LW FAS01RW Auxiliary
0.3A @ 125 VDC Switch
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference Auxiliary
instruction sheet DEH-40324 for wire lead colors. Switch
Lug Kits
Lug Kit Lug Kit w/
Lug Torque Single Lug (3 Lugs + Lug Cover) Control Wire Terminal
Ampere Rating Conductor Size (Max) Product No. Product No. Product No.
150A #14 - 3/0 Cu / Al 150 in-lb FCAL15 FCALK15 FCALK15LV
250A #8 - 250MCM Cu / #8 - 350MCM Al 275 in-lb FCAL16 FCALK16 FCALK16LV
Padlocking Device
Description Product Number
104.4
EUSERC Compliant Padlock FE1PE
35.0 35.0
Other Accessories
Description Product Number
LINE END
Rating Plug Removal Tool (SMR1 and SMR2 only) FAR ON
17.68° ±1.20°
Breaker External Test Kit (SMR1 and SMR2 only) FAT 1.58° ±1.10°
TRIP
Fin Cover FEUA3 96.40
64.00
Terminal Shield Fin Cover FEJS3 20.87° ±2.00° OFF
Nut Plate / Terminal Shoe FEJN3 22.14° ±1.60°
RESET
Terminal Shield Fin Cover FGJS3
LOAD END
Nut Plate / Terminal Shoe FGJN3
60.63 ±.30
5 feet SC5L
6 feet SC6L
Operating Cable
7 feet SC7L 107.75
[4.24]
8 feet SC8L 93.55 ±.30
9 feet SC9L [ 3.68 ±.01 ]
89.5
10 feet SC10L [ 3.5 ]
80.50 ±.30
104.4 [ 3.17 ±.01 ]
6 inches for NEMA 1, 3R, 12, 13 FCNHM1 77.0
35.0 35.0 [ 3.0 ]
Flange Mounted Handle 10 inches for NEMA 1, 3R, 12, 13 FCNHM2 52.60
[2.07] 17.5
Mechanism for Cable Operator 6 inches for NEMA 4 / 4X FCNHM3
10 inches for NEMA 4 / 4X FCNHM4
STDA Flange Same as Spectra 6 inch for NEMA 12/13 STDA1
Handles and STDA Flange Handle for Variable Same as Spectra 10 inch for NEMA 12/13 STDA2 LINE END
ON
Hardware Kits Depth Operating Mechanism Same as Spectra 6 inch for NEMA 4/4X STDA1X 17.68° ±1.20° 139.78 ±.30
1.58° ±1.10° 47.4
Same as Spectra 10 inch for NEMA 4/4X STDA2X 96.40
TRIP
[ 1.9 ]
Flange Stiffener Kit Use with FENFM 64.00 TDSR
20.87° ±2.00° OFF R3.3 125.53
Extender Kit Use with FENFM TDSR [ .1 ]
22.14° ±1.60°
Extended Drive Stud Use with FENFM TDS1 RESET
LOAD END
Door Hardware Kit NEMA 12/13 Door Hinged on Left, NEMA 12/13 2-point Kit TDV1 94.5
[ 3.7 ]
Door Hardware Kit NEMA 4/4X Door Hinged on Left, NEMA 4/4X 2-point Kit TDV1X
60.63 ±.30
Third Point Latch Kit For Use with TDV1L, TDC1LX Above TDV3
Door hardware Kit NEMA 12/13 Door Hinged on Right, NEMA 12/13 2-point Kit TDV1L 27.55
Third Point Latch Kit For Use with TDV1L, TDC1LX Above TDV3L 73.5
52.60
[ 2.07 ]
TDM Style Handle 35.0 35.0 77.0 [ 2.9 ]
Handle for FENRM2 / FENRM4 THCH45 81.0 [ 3.0 ]
Operators 108.36 ±.30
[ 3.2 ]
[ 4.27 ±.01 ] 111.76 ±.30
[ 4.400 ±.011 ]
107.75
[4.24]
93.55 ±.30
[ 3.68 ±.01 ]
89.5
[ 3.5 ]
80.50 ±.30
104.4 [ 3.17 ±.01 ]
77.0
35.0 35.0 [ 3.0 ] 35.0 R4.75
52.60
[2.07] 17.5 18.0
7.30
LINE END
ON
17.68° ±1.20° 139.78 ±.30
1.58° ±1.10° 47.4
TRIP
96.40 [ 1.9 ]
64.00
20.87° ±2.00° OFF R3.3 125.53
[ .1 ] 170.10 ±.50
22.14° ±1.60°
RESET
LOAD END
94.5 °5.70 °9.00
[ 3.7 ]
.50 4.95
60.63 ±.30
27.55
3.08
52.60 18.00
73.5 [ 2.07 ]
77.0 [ 2.9 ] 19.00
35.0 35.0 15.60 ±.30
81.0 [ 3.0 ]
[ 3.2 ]
108.36 ±.30
[ 4.27 ±.01 ] 111.76 ±.30
[ 4.400 ±.011 ]
Reference Publications
Available for download from www.geindustrial.com/publibrary
FG Breaker
1 Breaker Frame Rating Installation Instructions DEH-41639
2 FG Breaker Accessories
Product Description Bell Alarm & Aux. Switch DEH-40324
1 2 3
3 Standards & Markings Shunt Trip & UVR DEH-40259
4 Interrupting Ratings Padlock Device DEH-41031
4 Lug Kits DEH-40404
5 Lug Data & Torque Info
5 Auxiliary Contacts DEH-40261
6 6 Product Number Trip Unit Test Kit (FAT) DEH-40358
7 Push to Trip SMR2 Expansion Modules DEH-40408
SMR2 Modbus User Manual DEH-41181
7 SMR2 External Contact Module DEH-40409
Panelboards
Spectra™ Power Panel - Plug-in Kits - Single DEH-40420
Spectra™ Power Panel - Plug-in Kits - Double DEH-40419
Spectra™ Power Panel - Bolt-on Kits - Single DEH-40426
Spectra™ Power Panel - Bolt-on Kits - Double DEH-41047
Series Ratings DET-008
Outline Drawing 10085108SHI
Connection
Family Frame Size Interruption Rating Poles Voltage Trip Unit Type Trip Unit Protection Trip Unit/Frame Amps Configuration
F = Record Plus G = 600A (@480VAC) 2 = 2-Pole 6 = 600VAC D = PremEon S2 A = SMR2 standard 0250 = 250A SMR2 R0 = Standard No Lugs
N = 65kA in 3-Pole Frame K = SMR2 Z = SMR2 with ZSI 0400 = 400A SMR2 R1 = Line and Load Lugs3
H = 100kA 3 = 3-Pole B = LI 0600 = 600A SMR2 R2 = Load Lugs3
L = 150kA C = LI 400 Hz 250L = 250A PremEon R3 = Line Lugs3
P = 200kA G = LIG w/Ground Fault 400L = 400A PremEon
M = Mag-Only MCP 600M = 600A PremEon F = PremEon Standard
P = Mag-Only MCP No Lugs
w/Ground Fault
2Requires tamper-resistant Torx T15 tool for adjustment
3Lugs included but not installed
PremEon S
FG Breakers and MCP's equipped with the PremEon S trip unit use an adjustment knob to set the Amp rating (LT Pickup). The maximum
Amp rating of the breaker frame is shown in the "Current Sensor" column below. The available Amp rating settings (LT Pickup values),
by sensor, are as follows:
Current Sensor (A) Amp Settings (LT Pickup)
250 80, 90, 100, 110, 125, 135, 150, 165, 175, 190, 200, 215, 225, 240, 250
400 125, 150, 175, 180, 200, 225, 240, 250, 275, 300, 325, 340, 350, 375, 400
600 175, 200, 225, 250, 300, 325, 350, 400, 425, 450, 475, 500, 550, 575, 600
Record Plus™ FG with SMR2 Trip Unit, Breaker Frames without ZSI and Fixed Rating Plugs
2-Pole
Fixed Rating Plug Breaker Frame
UL 489 65kA IC @ 480 Vac UL 489 100kA IC @ 480 Vac UL 489 150kA IC @ 480 Vac UL 489 200kA IC @ 480 Vac
Ampere Current
Rating Product No. Sensor Product No. Product No. Product No. Product No.
100A FGRM2K0100
110A FGRM2K0110
125A FGRM2K0125 R0 R0 R0 R0
150A FGRM2K0150 250 R1 R1 R1 R1
FGN26KA0250_ _ FGH26KA0250_ _ FGL26KA0250_ _ FGP26KA0250_ _
175A FGRM2K0175 R2 R2 R2 R2
200A FGRM2K0200 R3 R3 R3 R3
225A FGRM2K0225
250A FGRM2K0250
175A FGRM2L0175
200A FGRM2L0200
R0 R0 R0 R0
225A FGRM2L0225
400 R1 R1 R1 R1
250A FGRM2L0250 FGN26KA0400_ _ FGH26KA0400_ _ FGL26KA0400_ _ FGP26KA0400_ _
R2 R2 R2 R2
300A FGRM2L0300
R3 R3 R3 R3
350A FGRM2L0350
400A FGRM2L0400
300A FGRM2M0300
350A FGRM2M0350 R0 R0 R0 R0
400A FGRM2M0400 600 R1 R1 R1 R1
FGN26KA0600_ _ FGH26KA0600_ _ FGL26KA0600_ _ FGP26KA0600_ _
450A FGRM2M0450 R2 R2 R2 R2
500A FGRM2M0500 R3 R3 R3 R3
600A FGRM2M0600
3-Pole
Fixed Rating Plug Breaker Frame
UL 489 65kA IC @ 480 Vac UL 489 100kA IC @ 480 Vac UL 489 150kA IC @ 480 Vac UL 489 200kA IC @ 480 Vac
Ampere Current
Rating Product No. Sensor Product No. Product No. Product No. Product No.
100A FGRM3K0100
110A FGRM3K0110
125A FGRM3K0125 R0 R0 R0 R0
150A FGRM3K0150 250 R1 R1 R1 R1
FGN36KA0250_ _ FGH36KA0250_ _ FGL36KA0250_ _ FGP36KA0250_ _
175A FGRM3K0175 R2 R2 R2 R2
200A FGRM3K0200 R3 R3 R3 R3
225A FGRM3K0225
250A FGRM3K0250
175A FGRM3L0175
200A FGRM3L0200
R0 R0 R0 R0
225A FGRM3L0225
400 R1 R1 R1 R1
250A FGRM3L0250 FGN36KA0400_ _ FGH36KA0400_ _ FGL36KA0400_ _ FGP36KA0400_ _
R2 R2 R2 R2
300A FGRM3L0300
R3 R3 R3 R3
350A FGRM3L0350
400A FGRM3L0400
300A FGRM3M0300
350A FGRM3M0350 R0 R0 R0 R0
400A FGRM3M0400 600 R1 R1 R1 R1
FGN36KA0600_ _ FGH36KA0600_ _ FGL36KA0600_ _ FGP36KA0600_ _
450A FGRM3M0450 R2 R2 R2 R2
500A FGRM3M0500 R3 R3 R3 R3
600A FGRM3M0600
Adjustable Rating Plugs for Record Plus™ FG with SMR2 Trip Unit
Ampere Current Sensor
Poles Rating Product No. Rating
160A FGRN2K0160 250
250A FGRN2K0250
2-Pole 250A FGRN2L0250 400
400A FGRN2L0400
600A FGRN2M0600 600
160A FGRN3K0160
250
250A FGRN3K0250
3-Pole 250A FGRN3L0250
400
400A FGRN3L0400
600A FGRN3M0600 600
Record Plus™ FG with SMR2 Trip Unit, Breaker Frames with ZSI and Fixed Rating Plugs
2-Pole
Fixed Rating Plug Breaker Frame
UL 489 65kA IC @ 480 Vac UL 489 100kA IC @ 480 Vac UL 489 150kA IC @ 480 Vac UL 489 200kA IC @ 480 Vac
Ampere Current
Rating Product No. Sensor Product No. Product No. Product No. Product No.
100A FGRM2K0100 $106.00
110A FGRM2K0110
125A FGRM2K0125 R0 R0 R0 R0
150A FGRM2K0150 250 R1 R1 R1 R1
FGN26KZ0250_ _ FGH26KZ0250_ _ FGL26KZ0250_ _ FGP26KZ0250_ _
175A FGRM2K0175 R2 R2 R2 R2
200A FGRM2K0200 R3 R3 R3 R3
225A FGRM2K0225
250A FGRM2K0250
175A FGRM2L0175
200A FGRM2L0200
R0 R0 R0 R0
225A FGRM2L0225
R1 R1 R1 R1
250A FGRM2L0250 400 FGN26KZ0400_ _ FGH26KZ0400_ _ FGL26KZ0400_ _ FGP26KZ0400_ _
R2 R2 R2 R2
300A FGRM2L0300
R3 R3 R3 R3
350A FGRM2L0350
400A FGRM2L0400
300A FGRM2M0300
350A FGRM2M0350 R0 R0 R0 R0
400A FGRM2M0400 R1 R1 R1 R1
600 FGN26KZ0600_ _ FGH26KZ0600_ _ FGL26KZ0600_ _ FGP26KZ0600_ _
450A FGRM2M0450 R2 R2 R2 R2
500A FGRM2M0500 R3 R3 R3 R3
600A FGRM2M0600
3-Pole
Fixed Rating Plug Breaker Frame
UL 489 65kA IC @ 480 Vac UL 489 100kA IC @ 480 Vac UL 489 150kA IC @ 480 Vac UL 489 200kA IC @ 480 Vac
Ampere Current
Rating Product No. Sensor Product No. Product No. Product No. Product No.
100A FGRM3K0100
110A FGRM3K0110
125A FGRM3K0125 R0 R0 R0 R0
150A FGRM3K0150 250 R1 R1 R1 R1
FGN36KZ0250_ _ FGH36KZ0250_ _ FGL36KZ0250_ _ FGP36KZ0250_ _
175A FGRM3K0175 R2 R2 R2 R2
200A FGRM3K0200 R3 R3 R3 R3
225A FGRM3K0225
250A FGRM3K0250
175A FGRM3L0175
200A FGRM3L0200
R0 R0 R0 R0
225A FGRM3L0225
R1 R1 R1 R1
250A FGRM3L0250 400 FGN36KZ0400_ _ FGH36KZ0400_ _ FGL36KZ0400_ _ FGP36KZ0400_ _
R2 R2 R2 R2
300A FGRM3L0300
R3 R3 R3 R3
350A FGRM3L0350
400A FGRM3L0400
300A FGRM3M0300
350A FGRM3M0350 R0 R0 R0 R0
400A FGRM3M0400 600 R1 R1 R1 R1
FGN36KZ0600_ _ FGH36KZ0600_ _ FGL36KZ0600_ _ FGP36KZ0600_ _
450A FGRM3M0450 R2 R2 R2 R2
500A FGRM3M0500 R3 R3 R3 R3
600A FGRM3M0600
Adjustable Rating Plugs for Record Plus™ FG with SMR2 Trip Unit
Ampere Current Sensor
Poles Rating Product No. Rating
160A FGRN2K0160 250
250A FGRN2K0250
2-Pole 250A FGRN2L0250 400
400A FGRN2L0400
600A FGRN2M0600 600
160A FGRN3K0160
250
250A FGRN3K0250
3-Pole 250A FGRN3L0250
400
400A FGRN3L0400
600A FGRN3M0600 600
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads
(#18 AWG). Shunt trip wire leads are black and UVR wire leads are blue.
355% pickup as required for use with External Ground Fault Protection.
Bell Alarm
Mechanisms Trip Units
Contact
Configuration Contacts Contact Rating Wire leads Product No. Product No.
1 NO (Form A) Standard 5A @ 277 VAC, #16 AWG FABAM10W FABAT10W
0.3A @ 125 VDC
1 NC (Form B) Standard 5A @ 277 VAC, #16 AWG FABAM01W FABAT01W
0.3A @ 125 VDC
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference
instruction sheet DEH-40324 for wire lead colors.
Auxiliary Switches
Left Mount Right Mount
Contact
Configuration Contacts Contact Rating Wire leads Product No. Product No.
1 NO (Form A) Standard 5A @ 277 VAC, #16 AWG FAS10LW FAS10RW
0.3A @ 125 VDC
1 NC (Form B) Standard 5A @ 277 VAC, #16 AWG FAS01LW FAS01RW
0.3A @ 125 VDC
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference
Auxiliary Auxiliary
instruction sheet DEH-40324 for wire lead colors. Switch Switch
Bell Alarm Bell Alarm
Mounting Locations and Limitations Mechanism Trip Unit
Mounting Locations
Padlocking Device
Description Product No.
Padlocking EUSERC Toggle FG1PE
Lug Kits
Top
Torque Strip Length
Pole/Lugs Location Wire Type Wire-Lug Lug-Strap Top Bottom Product No.
2 Top #8-400kcmil Cu, #8-#4 AWG Cu/Al 200 lb-in Bottom
#6-500kcmil Al 275 lb-in (31 N-m) (23 N-m) 7/8” 1 5/8” FCALK218H
Bottom #2/0-600kcmil Cu/Al #3 AWG-600kcmil Cu/Al 200 lb-in
375 lb-in (42 N-m) (23 N-m)
3 Top #8-400kcmil Cu, #8-#4 AWG Cu/Al 200 lb-in
#6-500kcmil Al 275 lb-in (31 N-m) (23 N-m) 7/8” 1 5/8” FCALK318H FCALK218H/FCALK318H
Bottom #2/0-600kcmil Cu/Al #3 AWG-600kcmil Cu/Al 200 lb-in
375 lb-in (42 N-m) (23 N-m)
Other Accessories
Product No.
Rating Plug Removal Tool (SMR1 and SMR2 only) FAR
Breaker External Test Kit (SMR1 and SMR2 only) FAT
Lug Cover Kit FGH1LCK
Hardware Kit (Tapped Holes) FGMSK1
Hardware Kit (Through Holes) FGMSK2
Dimensions (in.)
FG 600 Dimensions
Molded Case Switches Nonautomatic Trip, Includes Cu/Al line and load lugs. For optional lugs, see page 6-106 and 6-107.
Type Ampere Rating Number of Poles Voltage Rating Product Number
TEB 100 1 120 Vac, 125 Vdc TEB111Y1004
TEB 100 2 240 Vac, 250 Vdc TEB122Y1004
TEB 100 3 240 Vac TEB132Y1004
TEB 100 3 240Vac TEB132YT1009
TED 100 1 277 Vac, 125 Vdc TED113Y1004
TED 100 2 480 Vac, 250 Vdc TED124Y1004
TED 100 3 480Vac, 250Vdc TED134YT1009
TED 100 3 600Vac TED136YT1009
TED 100 3 600Vac TED136YT100A10
TED 150 2 480 Vac, 250 Vdc TED124Y1504,5
TED 150 3 480Vac, 250Vdc TED134YT1509
TED 150 3 600Vac TED136YT1509
TFJ 225 2 600 Vac TFJ226Y2254,6
TFJ 225 3 600 Vac TFJ236Y2256
TJJ 400 2 600 Vac, 250 Vdc TJJ426Y4007
TJJ 400 3 600 Vac TJJ436Y4007
Features
—Suitable for Reverse Feed
—UL Recognized File E-11592
—CSA Certified LR 40350
—IEC 947-2 690 Vac Max.
—SE 150 160 Ampere Max.
—SF250 250 Ampere Max.
—SG600 630 Ampere Max.
—SK1200 1250 Ampere Max.
—UL Current Limiting
High Interrupting Capacity Spectra™ RMS Motor Circuit Protectors—SE150 Line 3-Pole
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
65kAIC @480 Vac 100kAIC @480 Vac
Adjustable Instantaneous
Ampere Trip Ampere Range Product Current Product Product Product Wire
Rating Low High Number Sensor Number Number Number Range
3 11 39 SRPE7A3
7 SELA36AI0007 SEPA36AI0007 TCAL18
7 22 90 SRPE7A7
15 43 182 SRPE30A15
20 58 254 SRPE30A20 30 SELA36AI0030 SEPA36AI0030 TCAL18
25 73 332 SRPE30A25
30 87 415 SRPE30A30 14-3/0 Cu
40 118 501 SRPE60A40
50 148 637 SRPE60A50 60 SELA36AI0060 SEPA36AI0060 TCAL18
60 178 777 SRPE60A60 12-3/0 Al
70 206 863 SRPE100A70
80 236 999 SRPE100A80 100 SELA36AI0100 SEPA36AI0100 TCAL18
90 267 1138 SRPE100A90
100 297 1280 SRPE100A100
110 328 1426 SRPE150A110
125 374 1640 SRPE150A125 150 SELA36AI0150 SEPA36AI0150 TCAL18
150 450 1991 SRPE150A150
1Per UL 489, interruption ratings are not printed on the product label (interruption ratings are established based on a tested combination of the motor circuit protector and a
properly sized overload relay and contactor).
Accessories: See pages 6-39 to 6-44, 6-67 to 6-69 and 6-97 to 6-109.
Standard Capacity Mag Break Motor Circuit Protectors—Type TJC 3-Pole
30kAIC @480 Vac
Adjustable Instantaneous Complete Breaker (includes line and load lugs)
Trip Ampere Range Product
Ampere Rating Low High Number
330 1100 TJC36400E
550 1670 TJC36400F
400
1000 3300 TJC36400G
1200 4000 TJC36400B
1000 3300 TJC36600G
600
1800 6000 TJC36600H
High Interrupting Record Plus FE Motor Circuit Protectors - FE 250 Line with PremEon S
Mag-Only Motor Circuit Protector (With Tracking Short-Time) Mag-Only Motor Circuit Protector Plus Ground Fault (With Tracking Short-Time)
2-Pole Record Plus FE MCPs 2-Pole Record Plus FE MCPs
65kAIC @480 Vac 100kAIC @480 Vac 65kAIC @480 Vac 100kAIC @480 Vac
Current Sensor (A) Product Number Product Number Current Sensor (A) Product Number Product Number
25 FEN24DM025KF FEH24DM025KF 25 FEN24DP025KF FEH24DP025KF
60 FEN24DM060KF FEH24DM060KF 60 FEN24DP060KF FEH24DP060KF
125 FEN24DM125KF FEH24DM125KF 125 FEN24DP125KF FEH24DP125KF
150 FEN24DM150KF FEH24DM150KF 150 FEN24DP150KF FEH24DP150KF
250 FEN24DM250KF FEH24DM250KF 250 FEN24DP250KF FEH24DP250KF
High Interrupting Record Plus FG Motor Circuit Protectors - FG 600 Line with PremEon S
Mag-Only Motor Circuit Protector (With Tracking Short-Time)
2-Pole Record Plus FG Breakers
65kAIC @ 480 Vac 100kAIC @ 480 Vac 150kAIC @ 480 Vac 200kAIC @ 480 Vac
Current Sensor (A) Product Number Product Number Product Number Product Number
250 FGN26DM250LF FGH26DM250LF FGL26DM250LF FGP26DM250LF
400 FGN26DM400LF FGH26DM400LF FGL26DM400LF FGP26DM400LF
600 FGN26DM600MF FGH26DM600MF FGL26DM600MF FGP26DM600MF
Mag-Only Motor Circuit Protector Plus Ground Fault (With Tracking Short-Time)
TB1, 150A Frame, Noninterchangeable Trip (Includes line and load lugs)
Tri-Break™—Including
Current Limiters1 Lugs2 Replacement Current Limiters1
Adjustable Instantaneous Three-Pole Product No. Standard Optional1
Ampere Trip Amperes Range Product and Wire Sizes Product Product
Rating Low High Number (order 2 per pole) Number Number
15 Fixed TB13015BWE05
TCAL14
20 Fixed TB13020BWE05
#14-8 Lugs
25 Fixed TB13025BWE05
Cu-Al Furnished
30 Fixed TB13030BWE05 Not
with TB4E05
35 Fixed TB13035BWE05 TCAL 12 Available
Breaker
40 Fixed TB13040BWE05 #14-2/0
45 Fixed TB13045BWE05 Cu-Al
50 Fixed TB13050BWE09
60 Fixed TB13060BWE09
70 Fixed TB13070BWE09 Lugs
TCAL 12
80 Fixed TB13080BWE09 Furnished
#14-2/0 TB7E09 TB4E05
90 Fixed TB13090BWE09 with
Cu-Al
100 Fixed TB13100BWE09 Breaker
100NA – TB13BYWE093,4
Three-Pole 1000 Wye 577 Vac (Not UL Listed) — Without Line or Load Lugs1
Complete Breaker Frame Only Trip Unit Only
Thermal Magnetic Magnetic Only Thermal Magnetic Magnetic Only
Ampere Magnetic Instantaneous Trip Product Product Product Product Product
Rating Low High Number Number Number Number Number
E Frame — 100 Amperes Maximum, Noninterchangeable Trip
50 502 1802 TE131050MD TE131M050MD — — —
100 1002 5002 TE131100MD TE131M100MD — — —
How to Order
Use the circuit breaker mounting zone dimension table to determine the correct cable
length for the application and ensure that the 3-inch minimum bending radius is not
violated. Select the breaker mounted mechanism, operating cable and handle mecha-
nism below. Order as separate components.
Publication References
Breaker types E150, SE150, SF250, SG600 GEH-6290
Breaker type SK1200 GEH-6291
Type STDA Flange Handles and Variable Depth Operating Flange Stiffener Kit or Extended Length Drive Rod,
Mechanisms Product Number TDSR
—Designed to meet automotive duty specifications Provides rigid 3/8-inch diameter rod between STDA handle mount-
—NEMA 12/13 and 4/4X UL Component Recognized components, ing surface (flange or center mullion) and operating mechanism
File E-57253l CSA LR 10263 when STDA handle would otherwise not be rigidly supported.
—For right or left hand flange mounting – field convertible
—Mounting dimensions to fit standard flange enclosures 8 inches Rod length is 22 inches and my be cut to appropriate length. Also
– 24 inches deep used as extended-length drive rod for SDOM1A and SDOM3 when
—Detailed installation instructions standard 16 inch rod is not long enough. (Operating mechanism
—Superior strength Product Number SDOM6 for SK1200 includes two 22" unique
3/8-16x22 inch flange stiffener rods, Product Number TDSR and
drive rod.)
Flange Handle Construction
—Rugged die cast housing with provisions for locking in OFF Operating Flange Extended
position with up to three 3/16-inch to 5/16-inch padlocks Mechanism Stiffener Kit Drive Rod
Product Number Product Number Product Number
—O-ring seals for dirt-tight/oil-tight duty SDOM1A, SDOM3,
—Gusseted, 3/32-inch thick double-sided steel handle with large, TDOM1A through TDOM3
TDSR TDSR
Product Number STDA1 (6 inch) and STDA2 (10 inch) flange series
handles are interchangeable. While the SE150 through SG600 Extended Drive Stud, Product Number TDS1, TDS2
operating mechanisms can be easily operated with the 6-inch
STDA1 handle, the 10-inch STDA2 may be used to obtain lower This optional drive study permits locating the operating mecha-
operating force and/or to provide a proportionally larger handle nism 1-5/16 inches farther to the left (When flange handle is on
on large enclosures. STDA3 and STDA3X can be used only with right side) or to the right (when handle is on the left side) to
SDOM6 (for SK1200) operating mechanism. accommodate specific mounting restrictions. Not suitable for use
with SDOM4, SDOM6, TDOM4 and TDOM5 operating mechanisms.
NEMA 12/13 NEMA 4/4X Nominal Installation Drilling
Flange Handle Flange Handle Length Instruction Template Operating Mechanism Extended Drive Stud
Product Number Product Number Inches Number Number Product Number Product Number
STDA1 STDA1X 6 SDOM1A, SDOM3,
TDS1
STDA2 STDA2X 10 GEH-5314 GEH-5314 TDOM1A through TDOM3
STDA3 STDA3X 10 TDOM6, TDOM7 TDS2
Publication References
Instructions:
Door Hardware GEH-5322
Auxiliary Contact Kit GEH-5323
Flange Stiffener Kit or Extended Length Drive Rod GEH-5324
Extended Drive Stud GEH-5325
Operating Mechanism:
SDOM1A through SDOM4, SDOM6 GEH-5684
TDOM1A through TDOM1D GEH-5315
TDOM3 GEH-5317
TDOM4 and TDOM5 GEH-5318
TDOM6 and TDOM7 GEH-5319
Special Calibration
Contact GE sales office for availability. May void UL listing status.