0% found this document useful (0 votes)
40 views

Blue Gate Analog

The document provides installation and configuration instructions for a GSM gate device. It describes basic features such as polarity reversal detection, CLIP support, call billing, and beeps during calls. It also covers options, quality of GSM signals, antenna connection, programming modes, and direct calling.

Uploaded by

mateuszexwind
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
40 views

Blue Gate Analog

The document provides installation and configuration instructions for a GSM gate device. It describes basic features such as polarity reversal detection, CLIP support, call billing, and beeps during calls. It also covers options, quality of GSM signals, antenna connection, programming modes, and direct calling.

Uploaded by

mateuszexwind
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 19

G S M G A T E

Blue Gate A Brave

Installation guide V 2.5


Basic features:

Blue Gate A Brave is GSM Gate based on Telit GL865


equipped by a lot of adjustable features increased comfort of
service. It has been designed for GSM network
850/900/1800/1900Mhz.
 Polarity reversal of telephone line allows exact detection of
start and end of call.
 CLIP support all ordinary protocol.
 Call billing allows control exact call duration due tax pulses
12/16 kHz (1. pulse when outgoing call is picked up).
 Beeps in minute period into the call allows easy
identification of GSM call.
 Monitoring systém allows sending SMS to preprogrammed
number when voltage of Back up batteries drops, unit is
logged to GSM network, no picks up number of ringing
called person/connected device doesnt react for ringing)
etc.
 Direct Call (Baby Call) - Automatic dialing the number
stored on the SIM

Options:
 Option USB port with PC software allows you easy
configuration as same as sending and receiving SMS
messages ( via SMS mail sw)* or data transmission.
 You can add a backup battery for up to 10 h of operation at
power failure.
 Sending of status SMS : 1-30 days (adjustable);
 2 inputs with SMS sending feature when inputs status is
changed (up settings);
Thanks of many BlueGate features you can satisfy very wide
group of customers. By setting of permitted numbers to
memory of BlueGate you can restrict unrequested calls (to
public numbers).As same as you can set BlueGate to provides
incoming calls only.

1
INSTALLATION

antenna

SIM

telephone
line
telephone line

Power
USB option supply

telephone line

MiniUSB

2
Insert the SIM card up the picture and by press fix it in
operation position. Before inserting the SIM card we
recommend checking at various mobile phone state of
the SIM card (logging with or without PIN, PIN, etc.) and
set logging without PIN. When you want logging with PIN
you have to preprogrammed this PIN and set logging with
PIN (via table of programming). Without this setting the
Gate wont work.
DO NOT FORGET ANTENNA CONNECTION! The available
place for installation select up following point of view:

1. distance from PBX – possibility of GSM interferences to


other PBX lines as same as lenght of line from Gate to
PBX (max. 200m)

2. main 230 V for power supply of Gate

3. Quality of GSM signal at the installation place of GSM


Gate

Quality of GSM signal

The sound quality depends on BTS setting where you are


connected by the Gate. To find best place for antenna
mounting you can use either mobile phone or yellow LED
flashing on front of unit (via. Table at the end of manual). The
suitable signal power is 3 scales of mobile graduation.

To check and find best position from GSM signal point of view
you can use also GG SET ( configuration sw). More in manual
for GG SET.

3
Connection of antenna

When you connect magnetic antenna keep on mounting at


bigger iron subject. This subject makes „against-weight“ at its
depends the power of radiated signal

When you inserted SIM card as same as all cables are


connected (do not forget that Blue gate is connected on
external line not on extension) connect device to main
230V. Blue LED “feeding” lights up (via LED table) and starts
flashing yellow GSM LED in rhytm of busy tone. After cca 30
seconds the yellow LED start flashing up GSM signal strength
( via LED table).When pick up connected analogue phone or
call to BlueGate from PBX the LED of analogue line lights up
(green LED). In the phone is hearing dial tone of BlueGate. It
is ready to use.

The most often problems during Blue Gate


compact installation:
 All LED is not lighting.Problem in power supply. Check
connection to main 230V as same as connection of
adapter to BlueGate.

 The LED “power supply” lights. When you make connection


to Gate green LED is ON and in handset you hear busy
tone. Yellow LED flashing in period „GSM modul doesnt
communicate with CPU“. During work with USB could
be programmed fix communication rate for GSM modul.
Use USB to programm rate on „autobauding“.

 The yellow LED flashing in period „PIN unreadable“. After


calling to BlueGate you get busy tone. The SIM card

4
requires PIN, which is not preprogrammed or is
preprogrammed wrongly.

 The LED „communication to GSM„ is flash shortly one for


2 sec. After calling to BlueGate you are hearing busy
tone. BlueGate is not log into GSM network – bad signal.

 The yellow LED „communication to GSM„ is flashing up


signal strength“. After calling to BlueGate is not light up
green LED is not light up and in analogue phone is quiet.
It interrupted conduction of analogue line or so much big
resistance in current loop (for example:( longer cabel
between PBX and BlueGate).

 Tle yellow LED „communication to GSM„ is flashing up


signal strength“ as same as green LED lights up. Tle
PBX hold „pick up“ line of GSM Gate. By incoming call
you can remove this issue. In other cases check PBX
manual.

 The BlueGate works but call is disturbed by interference.


Incorrect position of antenna against telephone line.
Change antenna position.

Note:.
Default you make by parametr 99 in programming mode (via
programming table at page 11).
Alle LEDs flashing as same as tone types are mentioned in
tables at the end of manual.

5
USB
You can purchase USB tool for PC configuration of the unit. It
is optional. This tool is connected via 6 wire cable to the units
in middle of phone line. (via picture on page 2). You can
control GSM modul directly via virtual COM port. The Gate you
can further use ordinary GSM modem for data transmission,
internet connection or for SMS messages.
When unit is working as GSM modem then is busy for voice
connection. When you pick up the line you will hear busy tone.
The unit is monitoring data transmission by modem. The data
transmission can not be permanent therefore the unit stays in
data mode 10 seconds after finishing of data transmission.
Then is going back to Voice mode (calling).
The same is when you are calling over unit. It is busy for
data transmission.
The optional sw supply to unit for sending and receiving
SMS messages is SMS mail. It is working under Outlook,
Outlook Expres, Opera etc. And you can work with SMS as
with normal e mails. ( see manual for SMS mail). It works in
batches and allows programm communication interval (1 to 99
minutes) to BlueGate for sending and receiving SMS. Due this
we avoid situation that unit is permanentlky blocked by data
mode for voice communication.
Further functionality of USB is monitoring BlueGate
operation. It is possible record even incoming calls includes
time and CLIP, signal strength, etc..

6
CONFIGURATION

The programming mode is set after acknowledgement dialing


to Blue Gate.In the analogue phone is waiting tone. After
password inserting is tone changing to programming tone.
Then you can programming each features of Blue Gate (via
table of programming)

Progress of programming:
 Dial 2 digits number of programming feature.
 Dial 1 to 4 digits number for feature value programming.
 Wait for a tone of confirming request (3 short tones).
 Confirm the feature by dialling acknowledgement (#)
 Wait for confirming tone.
 Follow programming tone again.
 Finish programming by hang up a phone.

Example: programming of new permitted fix numbers (02)


to memory 09:
Dial acknowledgement (default is #). In phone you are hearing
waiting tone (). Dial password (default 0000).
Waiting tone is changing to programming tone ().
Dial 1902. Wait for tone of confirming request (3 short tones).
Confirm the feature by dialling acknowledgement (#). Wait for
confirming tone (one long tone). Finish programming mode by
hang up a phone.

Warning: After dialling of parametr value you have to wait


for 3 short tones and then dial acknowledgement # . Wait
for long tone confirm acceptation of this parametr .

7
Notes to each parametres:

11 - 19 When you programm some prefixes the BlueGate A


Bravellows outgoing calls starts by those prefixes only.
The others will get busy tone. When memories will be
empty the calling wont be restricted (default). Memory
of prefixes can content 1 digit only. If you insert 1 digit
only the BlueGate will check first position only.
Rewriting of memory – by storing of new fix-
numbers are old fix-numbers erased.
Erasing of memory - Memory you will erase by
storing of „nothing“. You
dial only number of memory which you want erase and
confim it.

22 very important feature is acknowledge character


setting. Default is #. When is # used for PBX features
you can change it on *.

32,35 The GSM phones requested command to connection on


inserted number. The BLUE GATE will send a
command immediately after acknowledge character
dialling (#).
27,37 These parameters can be entered (if necessary)
immediately after switching gates (Go into the
programming mode in the busy tone - see note. 3
below). Without their setting, in some cases, may not be
available SIM card (PIN, type of SIM card).
33 Direct Call - When the value is 01 (the shortest waiting
time to dialing) is activated "Direct Call" (Baby Call).
After picking up is no need to dial a phone number. Is
automatically dialed phone number stored on the SIM
card under the name DCALL. Store the number on the
SIM either by directly writing after inserting the SIM card

8
into any mobile phone or by software GGset (folder
"Phone Book")

Notes:

 Changes are valid after hang up only (finishing of


programming mode). It is very important especially in
acknowledge character changes- till hang up you must
use previous acknowledgement.

 After numbers dialing you must wait for confirming


request , insert acknowledge character and wait for
confirming tone. When you insert acknowledge
charater before wont be accepted.

 Switch to programming mode is possible even in busy


tone.
 Some parametres are possible to programm by PC only

9
Table of programming

  


0 0 n n n n Password nnnn to programming mode access 0 0 0 0
1 1 n n n n Memory x for permitted fix number (1 to 4 digits)
1 2 n n n n
1 3 n n n n
1 4 n n n n
1 5 n n n n
1 6 n n n n
1 7 n n n n
1 8 n n n n
1 9 n n n n
2 1 n Reversal polarity 0
n=0 OFF
n=1 ON
2 2 n Acknowledge character setting 0
n=0 - #
n=1 - *
2 3 n Type of dial tone n 0
n=0 – permanent tone
n=1 – dial tone up table of tones
n=2 - dial tone of public lines operator
n=3 - quiet
2 5 n Signalization to the call – short tone each minute 0
n=0 – tone is turn off
n=1 – tone is turn on
2 6 n Restriction of call duration 0
n=0 – without restriction
n=1 – call duration restricted at 10 minutes
2 7 n Type of SIM card 0
n=0 – SIM
n=1 - USIM
2 8 n outgoing DTMF INBAND/OUTBAND 0
n = 0 – INBAND DTMF
n = 1 – OUTBAND DTMF
3 2 n n Waiting for last number nn sec. (01 to 15) 0 6
(after finishing of dial by acknowledge character is sending immediately)
3 3 n n Waiting nn sec. for dial after pick up (00 to 99 sec) 0 0
(„00„ waiting is not limited)
(„01“ Direct Call)
3 5 n n Number of dialled numeral, after its is dial send immediatelly (lenght of 0 0
telephone number)
nn=00 – function none active
nn=01-19 – number of numeral telephone number
3 7 n n n n Storing of PIN 1 2 3 4
3 8 n Amplification of sound in outgoing direction (1 to 4) 1
3 9 n CLIR feature, switching OFF outgoing CLIP (#31#) 0
n=0 OFF
n=1 ON

10
7 1 x x y y Xx= 00 No charging pulses 0 0
Xx= 12 12 kHz charging pulses
Xx= 16 16 kHz charging pulses
Yy= 00 1 pulse only at the moment of connection
Yy= 01 to 99 seconds. Pulses each 01 up 99 seconds
7 2 n Amplification of sound in incoming direction (1 to 4) 1
7 3 n n= 0 CLIP is switch OFF 1
n= 1 FSK CLIP Bell
7 4 n Call progress tone 0
n=0 – OFF
n=1 - ON
7 5 n Roaming 1
n=0 – prohibited
n=1 - permitted
9 9 Default setting

11
Table of tones


 Dial tone (up setting)
 

Busy tone – short tone repeated
 

Ringing tone – long tone and pause


 repeated

Waiting tone – short tone repated with
 quick cadence.

Programming – short tone with quick
 cadence í

Confirmation inquiry - 3 short tones
 
Confirmation tone – long tone
 
Minute tone – short tone with 1 minute
 period

Call progress tone – short tones 3
 s after sending number to GSM
 

12
LED signalling

Permanent light
 


Permanent light
 

Doesnt light


Flashing in rhytm of busy


 tone

Flashing in rhytm of busy
tone
 

1- 5 flashes with period 4 sec.
 

Permanent light
 
Short lights off with period 2
 sec.

Flashing in period 2sec
 
Short flashes in period 2 sec.
 Gate is not registrate to GSM
network

13
ACU pack installation
Backup battery 9.6 V/800mAh

1. Open Gateway cabinet

2. Remove cover of glue tape at bottom part of ACU pack

14
3. Fix the ACU pack into Gateway cabinet. CAUTION for holes
for signalling LEDs! DO NOT COVER!

4. Rechargeable batteries may not be delivered in a charged


state. Start the gateway first
and wait for network log in.
Then connect cable from ACU
pack to appropriate connector..

5. Close the gateway cabinet


and leave ACU charged up at
least 2 hours without power
supply disconnection.

15
Technical parametres:

Type BlueGate A Brave


Operating position various
Operating conditions temperature: -20 C ÷ +40 C,
humidity: 10% ÷ 80% at 30 C
Dimensions (mm) 100mm x 130mm × 37mm
Weight

Part of power supply


Power supply ( adapter) 8-12VAC/DC, 500mA
Protection thermal fuse in adapter
Safety group ČSN EN 60950 group 2

Analogue telephopne line


telephone interface 2-wires
telephone conector RJ 11
Impedance 600  20%
Dial tone DTMF tt > 30 ms
outgoing INBAND/OUTBAND
Billing 12/16 kHz
Start and end of connection Polarity reversal

Supply conduction 24V


Current loop max 29 mA
Resistance of subscribers conduction max. 500 
Ringing 55 Vef / 50 Hz
Signalization 425 Hz 20Hz

CLIP FSK Bell

GSM:
mobile network Quad-Band 850/900/1800/1900Mhz
provider according SIM card (3V and 1.8 V)

USB version 1.1, virtual COM

16
Functionality:

 Waiting for dial after pick up 1 - 99 sec or unlimited - If set 1,


service Direct Call (Baby Call)
 Waiting for last digit of dial 1 - 15 sec
 Dial after preprogrammed number of digits 1 - 19
 Immediate dial sent up setting „#“ or „*“
 Permitted direction ( 9 memories of 4 digits numbers)
 CLIR
 CLIP
 Call billing ( tax pulses 12/16 kHz)
 outgoing DTMF INBAND/OUTBAND
 Reversal polarity ( start and end of call)
 Roaming ON / OFF
 Call duration control
 Time beeps in call
 GSM signal strength identification
 Sending of preprogrammed SMS to preprogrammed
number after voltage drops under setup level and taking
longer time than setup time
 Sending of preprogrammed SMS to preprogrammed
number at every logging to GSM network
 Sending of preprogrammed SMS to preprogrammed
number when number of none picks up rings into
connected device ( incoming call) is higher than setup level
 Sending of preprogrammed SMS to preprogrammed
number when inputs status is changed ( optional board)
taking longer time than setup time
 Periodical sending of status SMS in preprogrammed time
period 1-30 days. SMS includes: time and date of sending
(time setup on gateway clocks), GSM network status,
power supply voltage, GSM modul temperature, last call
number.

17
Alphatech spol. s r.o.
Jeremenkova 88
140 00 Praha 4
tel. 272 103 335, fax. 272 103 334
e-mail: [email protected]
internet: http://www.alphatech.cz
naše souřadnice GPS (WGS 84)
N 500235.5 E 142542.0

21.4.2017