0% found this document useful (0 votes)
31 views5 pages

Modular Distribution Blocks With Staggered Bars: Catalogue Numbers

This document provides information about modular distribution blocks with staggered bars including their general characteristics, range, technical characteristics, dimensions and weight. It contains details on the catalogue numbers, rated operational current, number of outputs and modules for both two-pole and four-pole distribution blocks.

Uploaded by

likis210
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
31 views5 pages

Modular Distribution Blocks With Staggered Bars: Catalogue Numbers

This document provides information about modular distribution blocks with staggered bars including their general characteristics, range, technical characteristics, dimensions and weight. It contains details on the catalogue numbers, rated operational current, number of outputs and modules for both two-pole and four-pole distribution blocks.

Uploaded by

likis210
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

87045 LIMOGES Cedex

Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88

Modular distribution blocks Catalogue numbers: 4 004 00 / 01 / 02 / 03


4 004 04 / 05 / 06 / 07 / 08 / 09 / 10 / 11
with staggered bars

CONTENTS
1. General characteristics . . . . . . . . . . . . . . . . . . . . 1
2. Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
3. Technical characteristics . . . . . . . . . . . . . . . . . . . 2
4. Dimensions - Weight . . . . . . . . . . . . . . . . . . . . . . 4
5. IP 2X terminal blocks. . . . . . . . . . . . . . . . . . . . . . 5
6. Photovoltaic application. . . . . . . . . . . . . . . . . . . 5

2. RANGE
M
 ake sure the power supply is disconnected before any intervention.
Strictly comply with instructions for installation and use. Two-pole
Rated Number of Number of
Cat. N° operational Input
1. GENERAL CHARACTERISTICS outputs (1) modules
current 40°C
Legrand modular distribution blocks with staggered bars enable safe and 4 004 00 40 A Internal 12 6
rapid two-pole or four-pole distribution. Compliant with standard EN 60947-
1, they combine electrical performance and mechanical robustness, as well 4 004 01 100 A Internal 6 4
as ergonomic design to facilitate the use of this key component of electrical
distribution systems. 4 004 02 100 A Internal 10 6
Thanks to a maximized cabling space, an optimized bars orientation and an 4 004 03 125 A Internal 14 8
adapted sizing of screw connections, cabling and connection are facilitated. (1)
For each bar
Moreover, the input and large sections outputs are staggered between each
bar to avoid overlapping of large conductors.
Four-pole
The 100/125/160 A four-pole distribution blocks with external input offer a
connection of the input separate from the outputs.
Rated Number of Number of
Cat. N° operational Input outputs (1) modules
current 40°C

4 004 04 40 A Internal 12 6

4 004 05 100 A Internal 6 4

4 004 06 100 A Internal 10 6

4 004 07 100 A External 11 8

4 004 08 125 A Internal 10 6


The connection points are also sufficiently spaced to allow the use of standard 4 004 09 125 A Internal 14 8
ferrules without problem related to insulating part.
A transparent insulating protection equips each brass bar for maximum 4 004 10 125 A External 15 10
safety. Moreover, a system integrated to this protection brakes the accidental 4 004 11 160 A External 14 10
unscrewing of the screws of unconnected connections.
(1)
For each bar
A protection also isolates the rear of the distribution block from the mounting
rail. Connection capacity, see page 2
A transparent protective cover, removable and rotating 180° (up to 125 A)
makes it possible to adapt to all wiring situations.

Technical data sheet: F03358EN/01 Updated : Created: 12/05/2021


1/5
Modular distribution blocks Catalogue numbers: 4 004 00 / 01 / 02 / 03
4 004 04 / 05 / 06 / 07 / 08 / 09 / 10 / 11
with staggered bars
3. TECHNICAL CHARACTERISTICS 3. TECHNICAL CHARACTERISTICS (continued)

3.1 Connection capacity 3.2 Connexion points dimensions


Two-pole range Each cylindrical hole is provided with a bevel to facilitate connection.
Input Outputs Cat. N° Input (mm) Outputs (mm)
Ie RIGID FLEXIBLE RIGID FLEXIBLE Nb. Ø 5.6
Cat. N° copper Nb. (1) copper of 4 004 00 Ø 5.6
40 °C copper conductor copper Ø 5.1
mod.
conductor (W/O ferrule) conductor conductor
(W/O ferrule)
Ø 7.6
2.5 to 10 1.5 to 10 4 004 01 Ø 7.6
2 mm2 mm2 Ø 5.6
4 004 00 40 A 2.5 to 10 1.5 to 10 6
mm2 mm2 1.5 to 6 0.75 to 4 Ø 7.6
10 mm2 mm2 4 004 02 Ø 7.6
10 to 25 6 to 16 Ø 5.6
1 mm2 mm2
4 004 01 100 A 10 to 25 6 to 16 4 Ø 7.6
mm2 mm2 2.5 to 10 1.5 to 10 4 004 03 Ø 8.6
5 mm2 mm2 Ø 5.6
2 10 to 25 6 to 16 Ø 5.6
10 to 25 6 to 16 mm2 mm2 4 004 04 Ø 5.6
4 004 02 100 A mm2 mm2 6 Ø 5.1
8 2.5 to 10 1.5 to 10
mm2 mm2 Ø 7.6
3 10 to 25 6 to 16 4 004 05 Ø 7.6
10 to 35 6 (2) to 25 mm2 mm2 Ø 5.6
4 004 03 125 A mm2 mm2 8
11 2.5 to 10 1.5 to 10 Ø 7.6
mm2 mm2 4 004 06 Ø 7.6
(1)
For each bar Ø 5.6
(2)
Flexible conductor less than 16 mm2 only with ferrule
Ø 7.6
4 004 07 Ø 8.6 (1)
Four-pole range Ø 5.6
Input Outputs Ø 7.6
4 004 08 Ø 8.6
Ie RIGID FLEXIBLE RIGID FLEXIBLE Nb. Ø 5.6
Cat. N° copper Nb. (1) copper of
40 °C copper conductor copper mod. Ø 7.6
conductor (W/O ferrule) conductor conductor
(W/O ferrule) 4 004 09 Ø 8.6
Ø 5.6
2 2.5 to 10 1.5 to 10
2.5 to 10 1.5 to 10 mm2 mm2 Ø 8.6
4 004 04 40 A mm2 mm2 6
10 1.5 to 6 0.75 to 4 4 004 10 Ø 7.6
mm2 mm2 8 x 9.5 (1)
10 to 25 6 to 16 Ø 5.6
1 mm2 mm2
4 004 05 100 A 10 to 25 6 to 16 4 Ø9
mm2 mm2 2.5 to 10 1.5 to 10
5 mm2 mm2 4 004 11 Ø 7.5
10 to 25 6 to 16 13 x 11 (1)
2 Ø 5.3
10 to 25 6 to 16 mm2 mm2
4 004 06 100 A mm2 mm2 6 External input
8 2.5 to 10 1.5 to 10 (1)

mm2 mm2
3 10 to 25 6 to 16
10 to 35 6 (2) to 25 mm2 mm2 3.3 Tightening torques
4 004 07 100 A mm2 (3) mm2 (3) 8
8 2.5 to 10 1.5 to 10
mm2 mm2 Cat. N° Tightening torque Tool
3 10 to 25 6 to 16
mm2 mm2 4 004 00
4 004 08 125 A 10 to 35 6 (2) to 25 6
mm2 mm2 2.5 to 10 1.5 to 10 4 004 01
7 mm2 mm2
10 to 25 6 to 16 4 004 02
3 mm2 mm2
4 004 09 125 A 10 to 35 6 (2) to 25 8 4 004 03
mm2 mm2 2.5 to 10 1.5 to 10
11 mm2 mm2 4 004 04
2 10 to 35 6 (2) to 25 Screwdriver
mm2 mm2 4 004 05 2 Nm
PZ-2 / flathead 5.5 mm
4 004 10 125 A 16 to 35 16 to 35 1 10 to 25 6 to 16 10 4 004 06
mm2 (3) mm2 (3) (4) mm2 mm2
2.5 to 10 1.5 to 10 4 004 07
12 mm2 mm2
4 004 08
1 10 to 35 10 to 25
mm2 mm2 (5) 4 004 09
1 10 to 35 10 to 16
mm2 mm2 4 004 10
4 004 11 160 A 35 to 70 35 to 70 10
mm2 (3) mm2 (3) 10 to 25 6 to 16 External inputs : 15 Nm 6 mm Allen spanner
4 mm2 mm2
4 004 11 Screwdriver
8 2.5 to 10 1.5 to 10 Outputs : 2 Nm
mm2 mm2 PZ-2 / flathead 5.5 mm
(1)
For each bar
(2)
Flexible conductor less than 16 mm2 only with ferrule
(3)
External input
(4)
Only flexible conductor with ferrule
(5)
Ferrules supplied for 25 mm2 connection

Technical data sheet: F03358EN/01 Updated: Created: 12/05/2021


2/5
Modular distribution blocks Catalogue numbers: 4 004 00 / 01 / 02 / 03
4 004 04 / 05 / 06 / 07 / 08 / 09 / 10 / 11
with staggered bars
3. TECHNICAL CHARACTERISTICS (continued) 3. TECHNICAL CHARACTERISTICS (continued)

3.4 Connection with Starfix ferrule 3.5 Electrical characteristics

Sections of flexible Compliant with standard EN 60947-1


Cat. N° Starfix cat. N°
Copper conductor Pollution degree 3 - Overvoltage Category III
0 376 64/66/67/68/69 Rated operational current Ie at 40°C
1.5 to 10 mm² 0 377 64/66/67/68 Rated insulation voltage Ui : 500 V
4 004 00
0 376 62/63/64/66/67 Rated impulse withstand voltage Uimp : 8 kV
0.75 to 4 mm²
0 377 62/63/64/66/67
0 376 68/69/70/72 Rated peak withstand current Ipk (1) :
6 to 16 mm²
0 377 68 Cat. N° Ipk (60 ms)
4 004 01
0 376 64/66/67/68/69 4 004 00 to 4 004 09 26 kÂ
1.5 to 10 mm²
0 377 64/66/67/68
4 004 10 20 kÂ
0 376 68/69/70/72
6 to 16 mm² 4 004 11 27 kÂ
0 377 68
4 004 02
0 376 64/66/67/68/69 (1)
Peak short-circuit current Icc
1.5 to 10 mm²
0 377 64/66/67/68
0 376 68/69/70/72/71 Rated short-time withstand current:
6 to 25 mm²
0 377 68 Cat. N° Icw (1 s)
0 376 68/69/70/72 4 004 00 to 4 004 10 4.5 kA
4 004 03 6 to 16 mm²
0 377 68 4 004 11 8.4 kA
0 376 64/66/67/68/69
1.5 to 10 mm²
0 377 64/66/67/68 Dissipated power:
0 376 64/66/67/68/69
1.5 to 10 mm² Power dissipated at rated
0 377 64/66/67/68 Cat. N°
4 004 04 operational current Ie
0 376 62/63/64/66/67
0.75 to 4 mm² 4 004 00 1W
0 377 62/63/64/66/67
0 376 68/69/70/72 4 004 01 6W
6 to 16 mm²
0 377 68 4 004 02 7W
4 004 05
0 376 64/66/67/68/69 4 004 03 12 W
1.5 to 10 mm²
0 377 64/66/67/68 4 004 04 2W
0 376 68/69/70/72
6 to 16 mm² 4 004 05 11 W
0 377 68
4 004 06 4 004 06 14 W
0 376 64/66/67/68/69
1.5 to 10 mm² 4 004 07 15 W
0 377 64/66/67/68
0 376 68/69/70/72/71 4 004 08 23 W
6 to 25 mm²
0 377 68 4 004 09 24 W
0 376 68/69/70/72
4 004 07 6 to 16 mm² 4 004 10 33 W
0 377 68
0 376 64/66/67/68/69 4 004 11 48 W
1.5 to 10 mm²
0 377 64/66/67/68
0 376 68/69/70/72/71 Derating:
6 to 25 mm² Coefficient to be applied to the rated operational current Ie for operation at
0 377 68
0 376 68/69/70/72 ambient temperature above 40°C
4 004 08 6 to 16 mm²
0 377 68
0 376 64/66/67/68/69 Ambient
1.5 to 10 mm² 40°C 45°C 50°C 55°C 60°C 65°C 70°C 75°C
0 377 64/66/67/68 temperature
0 376 68/69/70/72/71 Derating
6 to 25 mm² 1 0.92 0.86 0.8 0.73 0.65 0.56 0.45
0 377 68 coefficient
0 376 68/69/70/72
4 004 09 6 to 16 mm²
0 377 68
0 376 64/66/67/68/69 3.6 Other characteristics
1.5 to 10 mm²
0 377 64/66/67/68
Fixing on symmetrical / DIN rail by clipping
16 to 35 mm² 0 376 70/72/71/77 Cover opening with flathead screwdriver
0 376 68/69/70/72/71 Operating temperature at rated operational current Ie: - 25 ° to + 40 ° C
6 to 25 mm²
0 377 68 (derating for higher temperatures)
4 004 10
0 376 68/69/70/72 Installation altitude : 2000 m maximum (beyond : contact us)
6 to 16 mm²
0 377 68 Self-extinguishing 960 ° C - UL94 V-0 for supports of active parts
0 376 64/66/67/68/69 Transport and storage temperature: - 25 ° C to + 55 ° C
1.5 to 10 mm²
0 377 64/66/67/68 RoHS compliance
35 to 70 mm² 0 376 77/78
3.7 Materials
10 to 16/25 mm² (1) 0 376 69/70/72
4 004 11 Side parts: RAL 7035 gray polyamide
0 376 68/69/70/72 Bars: solid brass
6 to 16 mm²
0 377 68
Internal bar protection: Clear colorless polycarbonate
0 376 64/66/67/68/69
1.5 to 10 mm² External bar protection: RAL 7035 gray polyamide
0 377 64/66/67/68
Screws: zinc-plated steel
(1)
4 ferrules 25 mm2 supplied with the distribution block Cover: Transparent blue polycarbonate
Protection / rail : translucent PVC

Technical data sheet: F03358EN/01 Updated : Created: 12/05/2021


3/5
Modular distribution blocks Catalogue numbers: 4 004 00 / 01 / 02 / 03
4 004 04 / 05 / 06 / 07 / 08 / 09 / 10 / 11
with staggered bars
4. DIMENSIONS - WEIGHT 4. DIMENSIONS - WEIGHT (continued)
Two-pole 40/100/125 A Cover opening:
Cat. N° L (mm)
4 004 00 106
4 004 01 70.5
4 004 02 106
4 004 03 143
52.5

45 The cover becomes


L 51 removable in this position

Four-pole 40/100/125 A
Cat. N° L (mm)
4 004 04 106
4 004 05 70.5
4 004 06 106
4 004 08 106
4 004 09 143

The cover
becomes
93

removable in
this position

45 Cat. N° Weight (kg)


L 51.5
4 004 00 0.193
Four-pole 100/125 A (with external inputs)
4 004 01 0.124
Cat. N° L (mm)
4 004 07 139 4 004 02 0.192
4 004 10 176 4 004 03 0.240
4 004 04 0.370
4 004 05 0.238
4 004 06 0.350
4 004 07 0.407
4 004 08 0.342
The cover
becomes 4 004 09 0.466
93

removable in
this position 4 004 10 0.526
4 004 11 0.706
45
L 51.5

Four-pole 160 A (with external inputs) – Cat. N° 4 004 11


91.5
97

45.5
179 51.7

Technical data sheet: F03358EN/01 Updated: Created: 12/05/2021


4/5
Modular distribution blocks Catalogue numbers: 4 004 00 / 01 / 02 / 03
4 004 04 / 05 / 06 / 07 / 08 / 09 / 10 / 11
with staggered bars
5. IP 2X TERMINAL BLOCKS
IP 2X terminal blocks increase the number of earth or neutral outputs. They fix
directly to the distributor.

IP 2X Derating
Cat. N°
terminal block Voltage Current
4 004 00 0 048 34 (1) 40 A
4 004 01 0 048 32 (1) 80 A
4 004 02 0 048 34 (1) 80 A
4 004 03 0 048 35 (1) 100 A
4 004 04 0 048 44 (2) 40 A
4 004 05 0 048 42 (2) 80 A
400 V
4 004 06 0 048 44 (2) 80 A
4 004 07 0 048 45 (2) 80 A
4 004 08 0 048 44 (2) 100 A
4 004 09 0 048 45 (2) 100 A
4 004 10 0 048 45 (2) 100 A
4 004 11 0 048 45 (2) 100 A
(1)
T - (2) Neutral

6. PHOTOVOLTAIC APPLICATION

ELECTRICAL CHARACTERISTICS IN PHOTOVOLTAIC APPLICATION


Operational
Cat. N° Ui (1)
current 60°C
4 004 00 32 A
4 004 01 80 A
4 004 02 80 A 800 V =
4 004 03 100 A
(1)
Pollution degree 2
CONNECTION CAPACITY IN PHOTOVOLTAIC APPLICATION
INPUT OUTPUTS
Cat. N° « Solar » copper Number « Solar » copper
conductor of outputs (1) conductor
2 4 to 10 mm²
4 004 00 4 to 10 mm²
10 1.5 to 4 mm²
1 6 to 16 mm²
4 004 01 6 to 16 mm²
5 1.5 to 6 mm²
2 6 to 16 mm²
4 004 02 6 to 16 mm²
8 1.5 to 6 mm²
3 6 to 16 mm²
4 004 03 10 to 25 mm²
11 1.5 to 6 mm²
(1)
For each bar

Technical data sheet: F03358EN/01 Updated : Created: 12/05/2021